Secondary ion mass spectrometry(SIMS)
By:Mohsen Mahmoudi
Dr. Kolahdoz
School of Electrical and Computer EngineeringCollege of Engineering
University of TehranFall 91
Supervisor:
![Page 3: Secondary ion mass spectrometry (SIMS) By: Mohsen Mahmoudi Dr. Kolahdoz School of Electrical and Computer Engineering College of Engineering University.](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649e3f5503460f94b2f2cd/html5/thumbnails/3.jpg)
Click to edit Master text stylesSecond levelThird levelFourth levelFifth level
Outline
o Introduction to MassSpectrometero Introduction & Application of SIMSo How does SIMS work?o Limitations of SIMS
1/18 Secondary ion mass spectrometry (SIMS)
![Page 4: Secondary ion mass spectrometry (SIMS) By: Mohsen Mahmoudi Dr. Kolahdoz School of Electrical and Computer Engineering College of Engineering University.](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649e3f5503460f94b2f2cd/html5/thumbnails/4.jpg)
Click to edit Master text stylesSecond levelThird levelFourth levelFifth level
Mass Spectrometer (MS)
o Is a kind of machine which uses an analytical technique to measure the mass-to-charge ratio of charged particles(ions)
o This analytical technique is also known as Mass Spectrometry.
o MS works by ionizing chemical compounds to generate charged molecules or molecule fragments and measuring their mass-to-charge ratios
2/18 Secondary ion mass spectrometry (SIMS)
MS Application
Determining masses of particles
Determining the elemental composition of a sample or molecule
Elucidating the chemical structures of molecules, such
as peptides and other chemical compounds
![Page 5: Secondary ion mass spectrometry (SIMS) By: Mohsen Mahmoudi Dr. Kolahdoz School of Electrical and Computer Engineering College of Engineering University.](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649e3f5503460f94b2f2cd/html5/thumbnails/5.jpg)
Click to edit Master text stylesSecond levelThird levelFourth levelFifth level
General Structure of Mass Spectrometer
o Generally, a typical Mass Spectrometer consists of three parts: an ion source, a mass analyzer and a detector
o The function of the ion source is to produce ions from the sample.
o The function of the Mass Analyzer is to separate ions with different mass-to-charge ratios
o Then the numbers of different ions are detected by the detector
o Finally, the mass spectrum is generated after all the data have been collected
3/18 Secondary ion mass spectrometry (SIMS)
o The output, i.e. mass spectrum, is an intensity vs. m/z (mass-to-charge ratio) graph
![Page 6: Secondary ion mass spectrometry (SIMS) By: Mohsen Mahmoudi Dr. Kolahdoz School of Electrical and Computer Engineering College of Engineering University.](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649e3f5503460f94b2f2cd/html5/thumbnails/6.jpg)
Click to edit Master text stylesSecond levelThird levelFourth levelFifth level
Types of Mass Spectrometers
o Due to the differences in ionization techniques, various analyzers and detectors, the mass spectrometers can be divided into several types.
4/18 Secondary ion mass spectrometry (SIMS)
o For example: o ICP-MS (Inductively coupled plasma-mass spectrometry)o AMS (Accelerator mass spectrometry)o TIMS (Thermal ionization-mass spectrometry)o SSMS (Spark source mass spectrometry)o IRMS (Isotope ratio mass spectrometry)o SIMS( Secondary ion mass spectrometry)
![Page 7: Secondary ion mass spectrometry (SIMS) By: Mohsen Mahmoudi Dr. Kolahdoz School of Electrical and Computer Engineering College of Engineering University.](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649e3f5503460f94b2f2cd/html5/thumbnails/7.jpg)
Click to edit Master text stylesSecond levelThird levelFourth levelFifth level
Introduction to SIMS
o SIMS is based on the observation that charged particles (Secondary Ions) are ejected from a sample surface when bombarded by a primary beam of heavy particles.
5/18 Secondary ion mass spectrometry (SIMS)
![Page 8: Secondary ion mass spectrometry (SIMS) By: Mohsen Mahmoudi Dr. Kolahdoz School of Electrical and Computer Engineering College of Engineering University.](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649e3f5503460f94b2f2cd/html5/thumbnails/8.jpg)
Click to edit Master text stylesSecond levelThird levelFourth levelFifth level
Structure of SIMS
Typically, a secondary ion mass spectrometer consists of:
o Primary ion gun generating the primary ion beam primary ion column, accelerating and focusing the beam onto the sample
o High vacuum sample chamber holding the sample and the secondary ion extraction lens
o Mass analyzer separating the ions according to their mass- to- charge ratio
o Ion detection unit.
6/18 Secondary ion mass spectrometry (SIMS)
![Page 9: Secondary ion mass spectrometry (SIMS) By: Mohsen Mahmoudi Dr. Kolahdoz School of Electrical and Computer Engineering College of Engineering University.](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649e3f5503460f94b2f2cd/html5/thumbnails/9.jpg)
Click to edit Master text stylesSecond levelThird levelFourth levelFifth level
How Does SIMS Work?
o Typical schematic of a SIMS instrument.
7/18 Secondary ion mass spectrometry (SIMS)
![Page 10: Secondary ion mass spectrometry (SIMS) By: Mohsen Mahmoudi Dr. Kolahdoz School of Electrical and Computer Engineering College of Engineering University.](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649e3f5503460f94b2f2cd/html5/thumbnails/10.jpg)
Click to edit Master text stylesSecond levelThird levelFourth levelFifth level
Step 1, 2
High energy ions are supplied by an ion guno SIMS Primary Ion Sources:
8/18 Secondary ion mass spectrometry (SIMS)
![Page 11: Secondary ion mass spectrometry (SIMS) By: Mohsen Mahmoudi Dr. Kolahdoz School of Electrical and Computer Engineering College of Engineering University.](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649e3f5503460f94b2f2cd/html5/thumbnails/11.jpg)
Click to edit Master text stylesSecond levelThird levelFourth levelFifth level
Step 3, 4
Accelerating and focusing the beam onto the target sample
Which ionizes and sputters some atoms off the surfaceo This leads to the ejection (or sputtering) of both
neutral and charged (+/-) species from the surface.
9/18 Secondary ion mass spectrometry (SIMS)
![Page 12: Secondary ion mass spectrometry (SIMS) By: Mohsen Mahmoudi Dr. Kolahdoz School of Electrical and Computer Engineering College of Engineering University.](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649e3f5503460f94b2f2cd/html5/thumbnails/12.jpg)
Click to edit Master text stylesSecond levelThird levelFourth levelFifth level
Static and dynamic modes
10/18 Secondary ion mass spectrometry (SIMS)
![Page 13: Secondary ion mass spectrometry (SIMS) By: Mohsen Mahmoudi Dr. Kolahdoz School of Electrical and Computer Engineering College of Engineering University.](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649e3f5503460f94b2f2cd/html5/thumbnails/13.jpg)
Click to edit Master text stylesSecond levelThird levelFourth levelFifth level
Sputtering Effects
11/18 Secondary ion mass spectrometry (SIMS)
![Page 14: Secondary ion mass spectrometry (SIMS) By: Mohsen Mahmoudi Dr. Kolahdoz School of Electrical and Computer Engineering College of Engineering University.](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649e3f5503460f94b2f2cd/html5/thumbnails/14.jpg)
Click to edit Master text stylesSecond levelThird levelFourth levelFifth level
Step 5, 6
These secondary ions are then collected by ion lenseso Ions generated by this process form the secondary
beam and are subsequently transmitted within a continuous high vacuum environment to a mass spectrometer
Filtered according to atomic mass
12/18 Secondary ion mass spectrometry (SIMS)
![Page 15: Secondary ion mass spectrometry (SIMS) By: Mohsen Mahmoudi Dr. Kolahdoz School of Electrical and Computer Engineering College of Engineering University.](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649e3f5503460f94b2f2cd/html5/thumbnails/15.jpg)
Click to edit Master text stylesSecond levelThird levelFourth levelFifth level
Mass analyzers
Depending on the SIMS type, there are three basic analyzers available:
13/18 Secondary ion mass spectrometry (SIMS)
Quadrupole
time-of-flightsector
![Page 16: Secondary ion mass spectrometry (SIMS) By: Mohsen Mahmoudi Dr. Kolahdoz School of Electrical and Computer Engineering College of Engineering University.](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649e3f5503460f94b2f2cd/html5/thumbnails/16.jpg)
Click to edit Master text stylesSecond levelThird levelFourth levelFifth level
Step 7
Then projected onto an electron multiplier (top), Faraday cup ( bottom)
o Ion detectors
14/18 Secondary ion mass spectrometry (SIMS)
Faraday cup
Electron multiplier
![Page 17: Secondary ion mass spectrometry (SIMS) By: Mohsen Mahmoudi Dr. Kolahdoz School of Electrical and Computer Engineering College of Engineering University.](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649e3f5503460f94b2f2cd/html5/thumbnails/17.jpg)
Click to edit Master text stylesSecond levelThird levelFourth levelFifth level
Step 8
CCD screen
15/18 Secondary ion mass spectrometry (SIMS)
Mass spectrum diagramDepth of profiling3D Image
![Page 18: Secondary ion mass spectrometry (SIMS) By: Mohsen Mahmoudi Dr. Kolahdoz School of Electrical and Computer Engineering College of Engineering University.](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649e3f5503460f94b2f2cd/html5/thumbnails/18.jpg)
Click to edit Master text stylesSecond levelThird levelFourth levelFifth level
Limitations
o Generally does not produce quantitative analyses o Optical capabilities are typically limitedo Charging may be a problem in some sampleso There is commonly an image shift when changing from positive to
negative ion data collection mode; o Too much data
16/18 Secondary ion mass spectrometry (SIMS)
![Page 19: Secondary ion mass spectrometry (SIMS) By: Mohsen Mahmoudi Dr. Kolahdoz School of Electrical and Computer Engineering College of Engineering University.](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649e3f5503460f94b2f2cd/html5/thumbnails/19.jpg)
Click to edit Master text stylesSecond levelThird levelFourth levelFifth level
17/18 Secondary ion mass spectrometry (SIMS)
A Typical SIMS
![Page 20: Secondary ion mass spectrometry (SIMS) By: Mohsen Mahmoudi Dr. Kolahdoz School of Electrical and Computer Engineering College of Engineering University.](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649e3f5503460f94b2f2cd/html5/thumbnails/20.jpg)
Click to edit Master text stylesSecond levelThird levelFourth levelFifth level
References
[1] J. D. Plummer, M. D. Deal, and P. B. Griffin.“Silicon VLSI Technology: Fundamentals, Practice, and Modeling,” Prentice Hall, 2000
[2] L, Cheng. “Introduction to Mass Spectrometer,” Helsinki, 2007. http://www.bioacademy.gr
[3] P. K. Chu. “Secondary Ion Mass Spectrometry,” University of Hong Kong[4] http://www.chm.bris.ac.uk[5] http://serc.carleton.edu[6] http://en.wikipedia.org[7] http://www.eaglabs.com[8] http://researcher.watson.ibm.com
18/18 Secondary ion mass spectrometry (SIMS)
![Page 21: Secondary ion mass spectrometry (SIMS) By: Mohsen Mahmoudi Dr. Kolahdoz School of Electrical and Computer Engineering College of Engineering University.](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649e3f5503460f94b2f2cd/html5/thumbnails/21.jpg)
Thanks for Your Attention.
University of TehranSchool of Electrical and Computer
EngineeringFall 91