SeaRox - Sentiarwiumbracortiny-rmo.inforce.dk/media/1015652/rti product... · 2016. 3. 31. ·...

16
NEW PRODUCT NAMES SeaRox ® Marine & Offshore Insulation Board & Pipe Products Catalogue High Temperature Board (Slab) Flex, Wrap (Mat) & Pipe products PRODUCTS & SOLUTIONS – MARINE & OFFSHORE INSULATION

Transcript of SeaRox - Sentiarwiumbracortiny-rmo.inforce.dk/media/1015652/rti product... · 2016. 3. 31. ·...

Page 1: SeaRox - Sentiarwiumbracortiny-rmo.inforce.dk/media/1015652/rti product... · 2016. 3. 31. · thermal and fire protection in marine & offshore applications. SeaRox® pipe insulation

NEW

PRODUCT NAMES

2012

NEW

PRODUCT NAMES

2012

NEW

PRODUCT NAMES

2012

NEW

PRODUCT NAMES

2012NEWPRODUCT

NAMES

SeaRox® Marine & Offshore Insulation

Board & Pipe Products Catalogue High Temperature Board (Slab) Flex, Wrap (Mat) & Pipe products

PRODUCTS & SOLUTIONS – MARINE & OFFSHORE INSULATION

Page 2: SeaRox - Sentiarwiumbracortiny-rmo.inforce.dk/media/1015652/rti product... · 2016. 3. 31. · thermal and fire protection in marine & offshore applications. SeaRox® pipe insulation

SeaRox® Marine &Offshore InsulationPerformance Driven SolutionsFrom now on, all our insulation solutions for marine & offshore installations will be part of the SeaRox® product range. The new naming strategy will make it easier for engineers and specifiers to identify the right product for the right application by ignoring density and focusing on performance driven solutions. It also aligns ROXUL® with ROCKWOOL operating companies to create a globally harmonized pro-duct offering.

NEW NAME OLD NAME

SeaRox® SL 748NA RHM® 30ASeaRox® SL 328NA RHM® 40ASeaRox® SL 618NA RHM® 60ASeaRox® SL 638NA RHM® 70ASeaRox® SL 648NA RHM® 80ASeaRox® SL 658NA RHM® 100ASeaRox® SL 618NA RHM® 60 ACSeaRox® SL 968NA TECHTON 1200® Marine

New product names, logical structureEach product name is structured in the same clear way:

e.g.: SeaRox SL 968 MFF NA

Product range

Product identifierSL = Boards/SlabsFSL = Flexible Boards/SlabsPS = Pipe Insulation

Application code300 Series = Acoustics600 Series = Fire Resistance700 Series = Comfort/Multi-Purpose900 Series = Thermal Insulation

Facing optionsMFF = Reinforced Foil Facer

Local market specifications

2

Page 3: SeaRox - Sentiarwiumbracortiny-rmo.inforce.dk/media/1015652/rti product... · 2016. 3. 31. · thermal and fire protection in marine & offshore applications. SeaRox® pipe insulation

ROXUL’s SeaRox® Series of non-combustible marine stone wool products are designed for acoustic, comfort, thermal and fire protection in marine & offshore applications. SeaRox® pipe insulation products are designed for moisture intense applications such as steam and process pipes systems operating at temperatures up to 1200°F (650°C).

ROXUL focuses on Performance Driven Solutions which provides clarity and structure and easily helps you identify the right product for the right application.

Fire Resistant

The stone wool and recycled content combination in ROXUL’s marine & offshore insulations make these products non-combustible and fire resistant. These products are designed for operating temperatures up to 1200 °F (650 °C), withstanding the heat of up to 2150 °F (1177 °C) without melting. ROXUL marine & offshore insulations are excellent barriers to flame spread and critical lines of defence in fire control for personnel and equipment.

Noise Control

ROXUL mineral wool (stone wool) compositions have unique non-directional structures and densities to effectively reduce airflow and essentially, sound transmissions. These denser structures, coupled with tight joints, create effective barriers to pipe noise and contribute to much quieter, safer offshore and marine environments.

Water Repellent

The ROXUL marine & offshore product line does not absorb water or hold moisture. The dense stone wool based material naturally repels and drains water away from pipes without compromising R-value. These

products do not promote fungi, mildew, or bacteria growth and are chemically inert to eliminate corrosion.

Easy Installation

All ROXUL marine & offshore insulation is easy to handle on job sites. The products’ higher densities make them simple to cut with a serrated knife for clean straight edges providing a better fit at the point of installation. Quick and easy cutting means less waste and faster installation, which saves money on labor and lost production time. Quick and easy cutting also means fast and simple routine maintenance.

Technical Expertise

ROXUL offers innovative technical insulation solutions for the for the ship building & offshore market and the process & power generated industry worldwide. We are able to draw on in-depth expertise to ensure that end users in the ship building, offshore and the process industries are given the best and most advanced insulation solutions.

The key to our success is the combination of excellent insulation products and outstanding people who know exactly what they are talking about. Thanks to the team’s expertise and extensive experience, we can offer exceptional stone wool solutions and an impeccable service. With technical support on high level we are prepared to help you to choose the optimal solutions and secure the necessary documentation.

Better For The Workplace And The Environment: ROXUL® Marine & Offshore Insulation

With the push for sustainable development ROXUL leads the way with eco-friendly products that contain natural, inorganic materials made with recycled content.

3

Page 4: SeaRox - Sentiarwiumbracortiny-rmo.inforce.dk/media/1015652/rti product... · 2016. 3. 31. · thermal and fire protection in marine & offshore applications. SeaRox® pipe insulation

Certification and Documentation

All SeaRox® products and constructions have been tested according to a variety of approvals including:

n US Coast Guard n Transport Canada n Lloyd’s Register

SeaRox products have been tested to the relevant components of the IMO/FTP code.

References

ROXUL® has been active in the marine & offshore sector worldwide during the last 25 years. During recent years our material has been used frequently in all different kinds of projects like:

n Commercial ships n Passenger vessels and cruise liners n Yachts n Navy ships n Platforms and accommodation units

Recommended Product SelectorROXUL has developed a special range of marine & offshore products, which meets the requirements of IMO’s regulations at any time. For various applications there is a SeaRox product that has the required approval.

The table below provides an overview of the applications of the products in different constructions.

A construction (steel)

BULKHEAD & DECK SeaR

ox®

SL

328N

A (f

/ R

HM

® 4

0A)

Comfort

Acoustics

Pipes

Tanks

Air Ducts

Fire

‹475˚F

›475˚F

‹475˚F

›475˚F

Fire

Comfort insulation

Exhaust Pipes

SeaR

ox®

SL

618N

A (f

/ R

HM

® 6

0A)

SeaR

ox®

SL

638N

A (f

/ R

HM

® 7

0A)

SeaR

ox®

SL

648N

A (f

/ R

HM

® 8

0A)

SeaR

ox®

SL

658N

A (f

/ R

HM

® 1

00A

)

SeaR

ox®

FSL

618

NA

(f/

RH

60A

C)

SeaR

ox®

SL

748N

A (f

/ R

HM

® 3

0A)

SeaR

ox®

PS

968N

A (f

/ TE

CH

TON

® 1

200

Mar

ine)

4

Page 5: SeaRox - Sentiarwiumbracortiny-rmo.inforce.dk/media/1015652/rti product... · 2016. 3. 31. · thermal and fire protection in marine & offshore applications. SeaRox® pipe insulation

Acou

stic

s

SeaRox® SL 328NA is a semi rigid mineral wool (stone wool) insulation board (slab) designed for acoustical applications in marine installations.

Common application areas are living quarters and sound dampening of technical installations on board.

Benefits:

Benefits:

n Fire resistance properties, non-combustiblen Melting point of approximately 2150°F (1177°C)n Service temperature of 1200°F (650°C)n Water repellent yet vapor permeable materialn Lasting thermal performance not compromised by water

Certificates of Approvals: n US Coast Guard n Transport Canada n Lloyd’s Register n Tested to the relevant components of the IMO/FTP Code

SeaRox® SL 328NA Formerly: RHM® 40ANEW

NAME

Applications

Product Actual Density Applications

SeaRox® SL 328NA 4 lbs/ft3 (64 kg/m3) Acoustic insulation for living quarters and sound dampening of technical installations on board

Compliance

Product ASTM C612CAN/ULC S102 and ASTM E84 (UL 723) (Surface Burning)

ASTM C423*(Acoustical Performance)

(at 2” thickness)

ASTM C795(Corrosion Resistance)

SeaRox® SL 328NA IVA Pass NRC Rating 1 Pass

Thermal Performance - λ (BTU.in/hr.ft².°F)

Product 25°F 75°F 100°F

SeaRox® SL 328NA 0.22 0.25 0.26

Compliance and Applications

For type approval numbers and more technical information, consult technical data sheets available on www.roxul.com* For specific acoustical data contact the ROXUL® Technical Services Team.

PRODUCTS & SOLUTIONS – MARINE & OFFSHORE INSULATION

5

Page 6: SeaRox - Sentiarwiumbracortiny-rmo.inforce.dk/media/1015652/rti product... · 2016. 3. 31. · thermal and fire protection in marine & offshore applications. SeaRox® pipe insulation

SeaRox® 600 Series Fire Resistant Boards (Slabs), Wraps (Mats)NEW

NAME

Fire

Res

ista

nce

* Contact your ROXUL representative for more details.

Product Formerly Description

SeaRox® SL 618NA RHM® 60A High performance light-weight rigid board (slab) approved for fire protection requiring up to A-60 rating

SeaRox® SL 638NA RHM® 70A Mid-weight rigid board (slab) approved for fire protection requiring up to A-60 rating

SeaRox® SL 648NA RHM® 80A Heavy-weight pressure resistant board (slab) approved for fire protection requiring up to A-60 rating subject to light mechanical loads

SeaRox® SL 658NA RHM® 100A Heavy-weight pressure resistant board (slab) approved for fire protection requiring up to A-60 rating subject to medium mechanical loads

SeaRox® FSL 618NA RHM® 60AC Flexible board (slab) approved for fire protection requiring up to A-60 rating

600 Series Product Offering

SeaRox® 600 Series is designed for high temperature applications where fire protection requiring up to A-60 rating is essential. This series of boards (slabs) and wraps (mats) come in a variety of densities and dimensions and are available with foil facing upon request*. All products are easy to cut and install plus are fire resistant and water repellent.

Benefits:n Fire resistance properties, non-combustiblen Melting point of approximately 2150°F (1177°C)

Benefits:n Fire resistance properties, non-combustiblen Melting point of approximately 2150°F (1177°C)n Service temperature of 1200°F (650°C)n Water repellent yet vapor permeable material water and moisture resistant; impregnated with high-water repellent characteristicsn Lasting thermal performance not compromised by water

Certificates of Approvals: n US Coast Guard n Transport Canada n Lloyd’s Registern Tested to the relevant components of the IMO/FTP Code

6

Page 7: SeaRox - Sentiarwiumbracortiny-rmo.inforce.dk/media/1015652/rti product... · 2016. 3. 31. · thermal and fire protection in marine & offshore applications. SeaRox® pipe insulation

This product line is designed for fire protection in marine installations. Common application areas for these products are decks and bulkheads requiring up to A-60 rating.

For type approval numbers and more technical information, consult technical data sheets available on www.roxul.com

SeaRox® SL 600 Series Boards (Slabs) Formerly: RHM® 60A, 70A, 80A, 100ANEW

NAME

Fire

Res

ista

nceApplications

Product Actual Density Applications

SeaRox® SL 618NA 6 lb/ft3 - (96 kg/m3) High performance, fire resistant insulation of decks and bulkheads requiring light weight boards (slabs)

SeaRox® SL 638NA 7 lb/ft3 - (112 kg/m3) Fire resistant insulation of decks and bulkheads requiring mid-weight boards (slabs)

SeaRox® SL 648NA 8 lb/ft3 - (128 kg/m3) Fire resistant insulation of decks and bulkheads requiring heavy-weight boards (slabs) subject to light mechanical loads

SeaRox® SL 658NA 10 lb/ft3 - ( 160 kg/m3) Fire resistant insulation of decks and bulkheads requiring heavy-weight boards (slabs) subject to medium mechanical loads

Compliance

Product ASTM C612CAN/ULC S102 and ASTM E84 (UL 723)(Surface Burning)

ASTM C795(Corrosion Resistance)

SeaRox® SL 618NA IVB Pass Pass

SeaRox® SL 638NA IVB Pass Pass

SeaRox® SL 648NA IVB Pass Pass

SeaRox® SL 658NA IVB Pass Pass

Thermal Performance - λ (BTU.in/hr.ft².°F)

Product 75°F 100°F

SeaRox® SL 618NA 0.24 0.26

SeaRox® SL 638NA 0.24 0.26

SeaRox® SL 648NA 0.24 0.26

SeaRox® SL 658NA 0.24 0.26

Compliance and Applications

PRODUCTS & SOLUTIONS – MARINE & OFFSHORE INSULATION

7

Page 8: SeaRox - Sentiarwiumbracortiny-rmo.inforce.dk/media/1015652/rti product... · 2016. 3. 31. · thermal and fire protection in marine & offshore applications. SeaRox® pipe insulation

Fire

Res

ista

nce

The added flexibility makes the FSL 600 Series ideal for irregular applications for fire protection in marine installations. Common application areas for these products are decks and bulkheads requiring up to A-60 rating.

For type approval numbers and more technical information, consult technical data sheets available on www.roxul.com

SeaRox® FSL 600 Series Boards (Slabs) Formerly: RHM® 60ACNEW

NAME

Applications

Product Actual Density Applications

SeaRox® FSL 618NA 6 lb/ft3 - (96 kg/m3) Fire resistant insulation of decks and bulkheads requiring flexible boards (slabs)

Compliance

Product ASTM C553CAN/ULC S102 and ASTM E84 (UL 723)(Surface Burning)

ASTM C795(Corrosion Resistance)

SeaRox® FSL 618NA VII Pass Pass

Thermal Performance - λ (BTU.in/hr.ft².°F)

Product 75°F 100°F

SeaRox® FSL 618NA 0.24 0.26

Compliance and Applications

8

Page 9: SeaRox - Sentiarwiumbracortiny-rmo.inforce.dk/media/1015652/rti product... · 2016. 3. 31. · thermal and fire protection in marine & offshore applications. SeaRox® pipe insulation

Com

fort

/Mul

ti-Pu

rpos

e

SeaRox® SL 748NA is a semi rigid mineral wool (stone wool) insulation board (slab) designed for comfort/multi-purpose applications in marine installations. Common application areas are living quarters on board marine vessels or offshore platforms.

Benefits:n Fire resistance properties, non-combustiblen Melting point of approximately 2150°F (1177°C)n Service temperature of 1200°F (650°C)n Water repellent yet vapor permeable material Water and moisture resistant; impregnated with high-water repellent characteristicsn Excellent thermal resistance not compromised by water

Certificates of Approvals: n US Coast Guard n Transport Canadan Lloyd’s Register n Tested to the relevant components of the IMO/FTP Code

SeaRox® SL 748NA Formerly: RHM® 30ANEW

NAME

Applications

Product Actual Density Applications

SeaRox® SL 748NA 3 lb/ft3 - (48 kg/m3) Comfort/multi-purpose insulation for living quarters on board marine vessels or offshore platforms

Compliance

Product ASTM C612CAN/ULC S102 and ASTM E84 (UL 723) (Surface Burning)

ASTM C423(Acoustical Performance)

(at 2” thickness)

ASTM C795(Corrosion Resistance)

SeaRox® SL 748NA IVA Pass NRC Rating 0.95 Pass

Thermal Performance - λ (BTU.in/hr.ft².°F)

Product 25°F 75°F 100°F

SeaRox® SL 748NA 0.22 0.25 0.26

Compliance and ApplicationsCompliance and Applications

For type approval numbers and more technical information, consult technical data sheets available on www.roxul.com

PRODUCTS & SOLUTIONS – MARINE & OFFSHORE INSULATION

9

Page 10: SeaRox - Sentiarwiumbracortiny-rmo.inforce.dk/media/1015652/rti product... · 2016. 3. 31. · thermal and fire protection in marine & offshore applications. SeaRox® pipe insulation

Ther

mal

Insu

latio

n

SeaRox® PS 968NA Formerly: TECHTON® 1200 MarineNEW

NAME

SeaRox® SL 968NA is a pre-formed mandrel wound pipe section designed for moisture intense applications, such as steam and process pipe systems operating at temperatures up to 1200°F (650°C), where energy conservation, personnel protection and fire control are concerns.

The highly durable sections are supplied split and hinged for easy snap-on assembly, and are especially suitable for thermal and acoustic insulation of high temperature pipe work subject to mechanical loads in marine and offshore installations.

Benefits:n Fire resistance properties, non-combustiblen Melting point of approximately 2150°F (1177°C)n Service temperature of 1200°F (650°C)n Water repellent yet vapor permeable material Water and moisture resistant; impregnated with high-water repellent characteristicsn Excellent thermal resistance not compromised by water

Certificates of Approvals: n US Coast Guard n Transport Canadan Lloyd’s Register n Tested to the relevant components of the IMO/FTP Code

Applications

Product Nominal Density Applications

SeaRox® SL 968NA 8 lb/ft3 - (128 kg/m3) Thermal and acoustic insulation of high temperature pipe work subject to mechanical loads in marine installations

Compliance

Product ASTM C547 ASTM E84 (UL 723)(Surface Burning)

ASTM C795(Corrosion Resistance)

SeaRox® SL 968NA I, II, IV Pass Pass

Compliance and Applications

For type approval numbers and more technical information, consult technical data sheets available on www.roxul.com

Thermal Performance - λ (BTU.in/hr.ft².°F)

Product 100°F 200°F 300°F 400°F 500°F 600°F 700°F

SeaRox® SL 968NA 0.25 0.28 0.34 0.39 0.45 0.53 0.63

10

Page 11: SeaRox - Sentiarwiumbracortiny-rmo.inforce.dk/media/1015652/rti product... · 2016. 3. 31. · thermal and fire protection in marine & offshore applications. SeaRox® pipe insulation

Performance Driven Solutions

1

3

2

4

3

2

3

34

1

4

5

1

1 SeaRox® SL 700 Series

2 SeaRox® FSL 600 Series

3 SeaRox® SL 600 Series

4 SeaRox® PS 900 Series

5 SeaRox® SL 300 Series

Marine Applications

Offshore Applications

1 SeaRox® SL 700 Series

2 SeaRox® FSL 600 Series

3 SeaRox® SL 600 Series

4 SeaRox® PS 900 Series

PRODUCTS & SOLUTIONS – MARINE & OFFSHORE INSULATION

11

Page 12: SeaRox - Sentiarwiumbracortiny-rmo.inforce.dk/media/1015652/rti product... · 2016. 3. 31. · thermal and fire protection in marine & offshore applications. SeaRox® pipe insulation

A-Constructions

Steel Bulkhead

Product Density

lb/ft³ (kg/m³)

Thickness

inches(mm)

Water Absorbtion

ASTM C1104/1104M% of weight

A-15 through A-60 steel Bulkhead

SeaRox® SL 618NA 6 (96)

Plate 3” (76 mm)Stiffener 1.5” (38 mm) < 1 % weight

SeaRox® SL 638NA 7(112)

Plate 3” (76 mm)Stiffener 1.5” (38 mm) < 1 % weight

SeaRox® SL 648NA 8(128)

Plate 3” (76 mm)Stiffener 1.5” (38 mm) < 1 % weight

SeaRox® SL 658NA 10(160)

Plate 3” (76 mm)Stiffener 1.5” (38 mm) < 1 % weight

SeaRox® FSL 618NA 6 (96)

Plate 3” (76 mm)Stiffener 1.5” (38 mm) < 1 % weight

A-15 through A-60 steel Bulkhead restricted

SeaRox® SL 618NA 6 (96)

Plate 2” (51 mm)Stiffener 1.5” (38 mm) < 1 % weight

SeaRox® SL 638NA 7(112)

Plate 2” (51 mm)Stiffener 1.5” (38 mm) < 1 % weight

SeaRox® SL 648NA 8(128)

Plate 2” (51 mm)Stiffener 1.5” (38 mm) < 1 % weight

SeaRox® SL 658NA 10(160)

Plate 2” (51 mm)Stiffener 1.5” (38 mm) < 1 % weight

SeaRox® FSL 618NA 6 (96)

Plate 2” (51 mm)Stiffener 1.5” (38 mm) < 1 % weight

A-15 through A-60 steel Bulkhead - Pipe Penetration

SeaRox® PS 968NA 8(128) 18” (450 mm) lengths < 1 % weight

* Pin and washer spacing to be installed as per installation specifications. For more information contact your ROXUL® representitive.

*

*

*

*

*

Refer to www.roxul.com for US Coast Guard certificates

12

Page 13: SeaRox - Sentiarwiumbracortiny-rmo.inforce.dk/media/1015652/rti product... · 2016. 3. 31. · thermal and fire protection in marine & offshore applications. SeaRox® pipe insulation

Thermal and Comfort InsulationThe requirements of the indoor climate and comfort have become more stringent during the recent years. The insulation constitutes an important factor of this, as it ensures obtaining the correct temperature – as comfort insulation.

The great advantage of the SeaRox® products is that the high level of thermal insulation can be combined with excellent noise reduction capabilities and often fire protection constructions will also act as thermal comfort insulation.

All SeaRox® products comply with IMO non-combustibility and reaction to fire requirements. Additionally the products have excellent water repellent properties and thermal stability, which is important as the product is often placed directly against the outer construction with changing temperatures.

1: Thermal insulation can be used alone where there is no other demand for the deck and bulkhead.

2: Thermal insulation can also be used together with fire insulation or sound insulation.

In all cases when insulating against cold temperatures the wool must always be covered by a vapor tight surface. This surface can be aluminum foil or another kind of vapor barrier. The gaps should be tightly sealed with alu tape.

When adding additional insulation to a fire construction it should be documented and approved by the local surveyor.

The most common way of expressing thermal properties is by using the following nomenclature:

n Coefficient of the Thermal Transmission (U-value)n Thermal Resistance (R)n Thermal Conductivity (λ)It is important to note that the l-value for any given material varies with temperature.

Thermal Conductivity (λ) measurements on ROXUL® insulation products (nominal values):

Product λ @ 75 °F (25 °C) BTU.in/hr.ft².°F (W/mk)

SeaRox® SL 328NA 0.25 (0.036)

SeaRox® SL 618NA 0.24 (0.034)

SeaRox® SL 638NA 0.24 (0.034)

SeaRox® SL 648NA 0.24 (0.034)

SeaRox® SL 658NA 0.24 (0.034)

SeaRox® FSL 618NA 0.24 (0.034)

SeaRox® SL 748NA 0.25 (0.036)

SeaRox® PS 968NA 0.25 (0.035)*

* λ @ 100 °F (38 °C)

PRODUCTS & SOLUTIONS – MARINE & OFFSHORE INSULATION

13

Page 14: SeaRox - Sentiarwiumbracortiny-rmo.inforce.dk/media/1015652/rti product... · 2016. 3. 31. · thermal and fire protection in marine & offshore applications. SeaRox® pipe insulation

Glossary of Marine TermsSOLAS – An acronym for Safety Of Life At Sea. International Convention for the Safety of Life at Sea.

SOLAS Vessel – Vessel used in International waters

Transport Canada – The “Administration” as referred to in the FTP Code Book with the Administrative Body (competent authority) called Board of Steamship Inspection for Canada that issues Approvals/Certificates for Materials used in marine installations.

U.S.C.G. or USCG - An acronym for the United States Coast Guard

USCG – The “Administration” as referred to in the FTP Code Book with the Administrative Body (competent authority) called United States Department of Homeland Security, U.S. Coast Guard that issues Approvals/Certificates for Materials used in marine installations.

USCG Navigational & Vessel Inspection Circular No. 9-97 – Guide to Structural Fire Protection regulations as outlined in Title 46, CFR. It is intended as an explanation of accepted practices which have been found to comply with the intent of the USCG regulations. For example, Circular No. 9-97 provides other insulation arrangements including formulas for “A-30” and “A-15” Class rating steel bulkhead insulation thickness derived from an certified approved “A-60 Class” steel bulkhead installation test. This Navigational Circular is NOT applicable to and can NOT be used to derive any IMO FTP “A” Class Division installations. After 31 December, 2003, the Circular No. 9-97 is accepted for Vessels certified for U.S. domestic waters (not international waters) and only traveling to and from U.S. ports.

USCG 46 CFR 164.007 – USCG specification for tests on structural insulations under fire exposure conditions used on Vessels certified for U.S. domestic waters and only traveling to and from U.S. ports. Not applicable (after 31 December, 2003) for vessels operating in international waters that travel to or from other ports-of-call than the United States.

- CFR Title 46 – Shipping, Code of Federal Regulations - Part 164 – Materials - Subpart 164.007 – Structural Insulations

“Restricted” Application – Typical fire protection installation where the fire hazard is exposed to the insulation on the smooth side of a steel bulkhead with the stiffeners on either side.

“Unrestricted” Application – Worst case scenario with smooth side of bulkhead exposed to fire where it can warp from the fire hazard. The insulation is installed on the structural core and stiffeners placed on the non-fire side of the steel bulkhead.

Convention Vessel – Vessel used in International Waters

CFR – An acronym for Code of Federal Regulations – U.S.A.

Encasement of Stiffener – terminology used when a stiffener is boxed, mitered or wrapped with approved insulation.

FTP – An acronym for Fire Test Procedures

FTP Code – IMO book of fire tests protocol titled “International Code for Application of Fire Test Procedures,” occasionally referred to as IMO Resolution MSC.61(67).

IMO – An acronym for International Maritime Organization

IMO Resolution (Res.)A.799 – New IMO/FTP Code requirements for materials to be “non-combustible” as determined in accordance with Test Method ISO-1182:1990 except following the criteria of Annex 1, Part 1-Non-Combustibility test in the FTP Code book.

IMO Res. A.754(18) – New IMO/FTP Code recommendation on Fire Resistance tests for “A”, “B”, and “F” Class Divisions. Certificates of Approvals are issued under this requirement for testing various Divisions (Bulkheads, decks, doors, ceilings, panels, and linings) installations following a time/temperature furnace curve up to 1733º F (945º C). Approvals are specific to the type of bulkhead or deck installation, with differentiations between steel, aluminum, and other metals. “A-60” Class Division Installation – See below: Class = Classification Division = Bulkhead or Deck or Door or… Class “A-60” = Classification given for not exceeding the fire resistance test maximum criteria in 60 minutes Installation = Approved construction which includes structural core and stiffener insulations, attachments, attachment spacing and insulation joints

IMO FTP Code Res. A.653(16) – Surface flammability procedures that must be used to test finishes and adhesives as a composite relative to its’ use in practice. This is NOT like an ASTM E84 test procedure.

Lloyd’s Register – A classification society providing independent third-party certification verifying a product, system or manufacturing process against published criteria.

MSC – An acronym for Maritime Safety Committee

Nominal Density – Actual insulation product densities, as determined by ASTM Test Method C 303 are used for all marine fire resistance applications – Nominal density used in the traditional sense, that is, actual density +/- 10% by weight manufacturing tolerances as specified in IMO FTP Code Res. A.754(18).

14

Page 15: SeaRox - Sentiarwiumbracortiny-rmo.inforce.dk/media/1015652/rti product... · 2016. 3. 31. · thermal and fire protection in marine & offshore applications. SeaRox® pipe insulation

SeaRox®

Special Order Marine & Offshore Insulation Products In addition to the standard SeaRox products ROXUL® also offers a variety of special order products as follows:

NEW NAME OLD NAMEn Comfort InsulationSeaRox® MA 700 GS Shiprock PlusSeaRox® MA 700 ALU Shiprock AluSeaRox® SL 720 Marine Batts 32SeaRox® MA 720 ALU Marine Batts 32 RLSeaRox® SL 740 Marine Batts 45SeaRox® MA 740 ALU Marine Batts 45 RL

n Acoustic InsulationSeaRox® SL 320 Marine Slab 60SeaRox® SL 340 Marine Slab 80SeaRox® Acoustic Foil Marine Acoustic Foil

n Outfitting InsulationSeaRox® SL 436 Marine Slab 140SeaRox® SL 440 Marine Slab 150SeaRox® SL 470 Marine Slab 180SeaRox® SL 480 Marine Slab 200

NEW NAME OLD NAMEn Firesafe Insulation

SeaRox® WM 620 Marine Wired Mat 90SeaRox®WM 640 Marine Wired Mat 105SeaRox® SL 620 Marine Firebatts 100SeaRox® SL 640 Marine Firebatts 130SeaRox® SL 660 HC Firebatts 150SeaRox® WM 660 HC Wired Mat 150SeaRox® PS 620 ALUSC Marine Firebatts 100 PS

n Thermal InsulationSeaRox® SL 970 Marine Firebatts 110SeaRox® LM 900 ALU Marine Lamella Mat 32SeaRox® WM 950 Marine Wired Mat 80ProRox® PS 960 ALU ROCKWOOL 800*

n JacketingProRox® Rocktight ROCKWOOL Rocktight

H construction

BULKHEAD & DECK SeaR

ox®

MA

700

GS/

ALU

d

Comfort

Acoustics

Pipes

Tanks

Air Ducks

Fire

‹250˚C

›250˚C

‹250˚C

›250˚C

Fire

Comfort insulation

Exhaust Pipes

SeaR

ox®

SL

720

/ M

A 7

20 A

LU

SeaR

ox®

SL

740*

/ M

A 7

40 A

LU

SeaR

ox®

SL

320

SeaR

ox®

SL

340

SeaR

ox®

SL

440

/ SL

480

SeaR

ox®

SL

436

/ SL

480

SeaR

ox®

SL

620

A construction Fire

SeaR

ox®

SL

640

SeaR

ox®

SL

970

SeaR

ox®

WM

660

SeaR

ox®

SL

660

SeaR

ox®

LM

900

ALU

SeaR

ox®

WM

950

/ W

M 6

20 /

WM

640

SeaR

ox®

PS

960

/ P

S 96

0 A

LU

For more details contact your ROXUL® representative.

PRODUCTS & SOLUTIONS – MARINE & OFFSHORE INSULATION

15

Page 16: SeaRox - Sentiarwiumbracortiny-rmo.inforce.dk/media/1015652/rti product... · 2016. 3. 31. · thermal and fire protection in marine & offshore applications. SeaRox® pipe insulation

ROXUL INC. 420 Bronte Street South Suite 105, Milton, Ontario L9T 0H9 Tel: 1-800-265-6878www.roxul.com

10/1

4SeaRox® is registered trademarks of ROXUL Inc.®/TM: US - owner ROCKWOOL International A/S used under license; Canada - owner ROXUL Inc.

DISCLAIMER AND LIMITATION OF LIABILITY: The statements and data contained in this brochure are for general information purposes ONLY. They are NOT specific technical recommendations as to any particular design or application and the ultimate determination as to product suitability is the sole responsibility of the installer or end user. Although the information contained herein, including ROXUL product descriptions, is believed to be correct at the time of publication, accuracy cannot be guaranteed. ROXUL fully reserves the right to make product specification changes, without notice or obligation, and to modify or discontinue any of its products at any time. In no event shall ROXUL be liable for any direct, indirect, or consequential damages of any kind arising from information contained in this brochure, including, but not limited to, claims for loss of profits, business interruption, or damages to business reputation. This limitation of liability shall apply to all claims whether those claims are based in contract, tort, or any legal cause of action.

A Global Leader

ROXUL Inc. is part of ROCKWOOL International, the largest producer of stone wool insulation, which is made from natural basalt rock and recycled material. ROCKWOOL International was founded in 1909 and today operates worldwide with more than 9,800 employees, with 28 factories across three continents.

ROCKWOOL has over 75 years in the insulation business and for 25 years ROXUL® has been serving the North American market, manufacturing stone wool insulation products for residential, commercial, industrial and OEM applications.

ROXUL is the Better Insulation

ROXUL is an innovative insulation offering a world of green features. When ROXUL is the specified insulation, companies will receive a superior product along with the technical expertise of the ROXUL team to meet all insulation requirements.

Environmentally Sustainable

Our stone wool production process utilizes some of the most advanced technology available. The last decade has seen a new generation of ROXUL manufacturing facilities that are designed to lower our environmental footprint. These endeavors have included the capture and recycle rainwater, reduction in energy consumption, and zero waste to landfill by the recycling of raw materials back into the production process. ROXUL facilities also use natural lighting and re-purpose water used during the manufacturing process to minimize the impact on the environment and surrounding community resources.

ROXUL insulation is created using naturally occurring, inorganic raw materials and reuses waste from other manufacturers as well as from our plants. Stone wool insulation is noncombustible and achieves its thermal performance without the use of blowing agents. The products therefore do not off-gas over time, contributing to a sustainable environment.

Each ROXUL plant uses a varying combination of new and recycled content in order to remain efficient and environmentally friendly. ROXUL is committed to improving our overall efficiencies which further solidifies our commitment to environmental stewardship within the organization.

For further details contact your ROXUL sales representative. Please visit www.roxul.com for the latest information.

Surface Burning Characteristics: ULC Listed to Canada Standard CAN/ULC S102;UL Classified to UL 723