SeaLite Lumos - deepsea.com · SeaLite® Lumos Operator’s Manual 4 tant This is the safety alert...

15
DEEPSEA POWER & LIGHT ® Operator’s Manual T: (858) 576-1261 F: (858) 576-0219 4033 Ruffin Road San Diego, CA 92123- 1817 USA www.deepsea.com [email protected] REV 08/27/18 SeaLite ® Lumos

Transcript of SeaLite Lumos - deepsea.com · SeaLite® Lumos Operator’s Manual 4 tant This is the safety alert...

Page 1: SeaLite Lumos - deepsea.com · SeaLite® Lumos Operator’s Manual 4 tant This is the safety alert symbol It is used to alert you to potential personal inury haards. Obey all safety

DE

EP

SE

AP

OW

ER

& L

IGH

T ®

Operator’s Manual

T: (858) 576-1261F: (858) 576-0219

4033 Ruffin RoadSan Diego, CA 92123- 1817 USA

[email protected]

REV 08/27/18

SeaLite® Lumos

Page 2: SeaLite Lumos - deepsea.com · SeaLite® Lumos Operator’s Manual 4 tant This is the safety alert symbol It is used to alert you to potential personal inury haards. Obey all safety

Specification Overview

* Specifications subject to change without notice.2

SeaLite® Lumos Operator’s Manual

SLL-1000 SLL-2000Optical SpecificationsTypical Lumen Output 3,000

Color Day Light White 5000K - 6500K Contact Sales for Color Options

Beam Angle (HPFW) Flood: 85º or Spot: 32º

Environmental SpecificationsDepth Rating 6,000 m

Operational Temperature -10º C to 40º C [14º F to 104º F]

Electrical Specifications

Voltage 90~270 VAC, 50/60Hz100~350 VDC 10~36 VDC

Current 0.27A @ 120 VAC0.13A @ 240 VAC

1.10A @ 24 VDC2.65A @ 10 VDC

Power 32.0W max 26.5W max

Dimming AC phase control (TRIAC) variable voltage (VARIAC) 0~5 VDC

Mechanical Specifications Housing Titanium

Port Sapphire

Outer Diameter 47.5 mm [1.87 in.]

Overall Length (Without Connector) 154.3 mm [6.08 in]

Weight in Air 710 g [1.56 lbs]`

Weight in Water 400 g [0.88 lbs]`

Connector

Default SEACON MCBHMPContact sales for more options.

Dimensions

1.8747.5

1.6942.9

2.4762.6

2.4060.9

1.5940.3

.5915

6.08154.3

7.35186.7

1.8547

1.0025.4

1.0025.4

4X 1/4-20 UNCOR

4X M6 x 1.0

[inch]mm

Standard Connectors

MCBH3MP (High Voltage AC/DC)1 = Hot (DC +)2 = Neutral (DC -)3 = Chassis

MCBH5MP (Low Voltage DC)1 = DC+2 = DC-3 = Chassis4 = Not Used5= 0-5 V DC Control (0-5V DC Control referenced to Pin 2)

*Other connector options are available upon request.

1 Titanium Housing, Universal Driver, Spot Reflector model.

1

2

3

3

5

4

12

Page 3: SeaLite Lumos - deepsea.com · SeaLite® Lumos Operator’s Manual 4 tant This is the safety alert symbol It is used to alert you to potential personal inury haards. Obey all safety

SeaLite® LumosOperator’s Manual

3

Table of Contents

Specification Overview 2

Table of Contents 3

Safety Symbols 4 General Notes and Warnings 4

Pre Dive Inspection 4

Post Dive Inspection 4-5

Troubleshooting 5

Flooded Light Repair 5

Limited Warranty 5

RMA Procedure for Repair 5

Appendix A: Dimming Response Curve 6

Appendix B: Driver Efficiency 9

Appendix C: LVDC Step Response Curve 11

Appendix D: Beam Patterns 14

Page 4: SeaLite Lumos - deepsea.com · SeaLite® Lumos Operator’s Manual 4 tant This is the safety alert symbol It is used to alert you to potential personal inury haards. Obey all safety

SeaLite® Lumos Operator’s Manual

4

Safety SymbolIn this operator’s manual and on the product, safety symbols are used to communicate important safety information. This section is provided to improve understanding of these symbols.

This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.

DANGER indicates a hazardous situation which, if not avoided, could result in death or serious injury.

WARNING indicates a hazardous situation which, if not avoided, could result in damage to the product or bodily harm.

CAUTION indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.

NOTICE indicates information that relates to the protection of property.

This symbol means read the operator’s manual carefully before using the equipment. The operator’s manual contains important information on the safe and proper operation of the equipment.

This symbol means always wear safety glasses with side shields or goggles when handling or using this equipment to reduce the risk of eye injury.

This symbol indicates the risk of electrical shock.

DANGER

! WARNING

CAUTION

NOTICE

General Notes and WarningsYou may run your SeaLite® Lumos in air. As the light heats up you will notice that the output will diminish. This is normal, and the light will return to full brightness once it is submerged and allowed to cool down.

DANGER

When the SeaLite® Lumos is operated in air, the body may reach temperatures in excess of 65° C. These temperatures may be enough to cause burns if the light is handled without protective clothing.

Do not operate any high voltage electrical equipment in or around water without using a Ground Fault Interrupt circuit (GFI) and an isolation transformer, especially when divers are in the water.

WARNING

Do not clean any part of the light head with any type of alcohol.

There should be no reason to ever open the body of your SeaLite® Lumos light. There are no user serviceable parts inside your new underwater light. Your SeaLite® Lumos was thoroughly pressure tested prior to leaving the factory to confirm the integrity of the complete assembly. Opening the housing may cause potential problems when resealing.

Pre and Post Dive InspectionCheck to make sure that the rear bulkhead connector is secure before deployment.

Check the following areas for previous damage, wear or corrosion: rear bulkhead connector, power cable, front window.

Rinse your SeaLite® Lumos in fresh water after use in saltwater.

DANGER

After each deployment, carefully check to make sure the light is operational and has not flooded. If it gets flooded, upon surfacing, the light can become internally pressurized, which may be potentially dangerous. Additionally, if the power remains on when the light has partially flooded, it is possible for electrolytic generation of an explosive mixture of hydrogen and oxygen gases. If a light appears flooded upon removal from the water, it should be treated as potentially dangerous. Point the light away from persons and valuable equipment and make sure that the power is disconnected. See the Flooded Light Repair procedure for more information.

Page 5: SeaLite Lumos - deepsea.com · SeaLite® Lumos Operator’s Manual 4 tant This is the safety alert symbol It is used to alert you to potential personal inury haards. Obey all safety

SeaLite® LumosOperator’s Manual

5

Troubleshooting If the light stops working while underwater assume that it has been flooded. See Flooded Light Repair procedure below.

Once it has been determined that the light is not flooded, or if it does not turn on during pre-deployment checks, check the input power cable/inline connector to make sure that correct voltage is being supplied, and that the correct pinout is being used. See page 2 of this manual for electrical specs and connector pin assignments.

If the light still does not work, return it to DSPL using the RMA Procedure for Repair below.

Flooded Light RepairIf the light stops working while underwater, assume that it has been flooded. When working on a potentially flooded light, it is important to use appropriate personal protective equipment to include, at a minimum, eye and hand protection.

1. Place the light face down on a table making sure that the connector side is facing up.

2. Slowly unscrew the connector/socket assembly to allow any internal pressure to be equalized.

3. Once it is determined that the light is not internally pressurized, it is recommended that the light be returned to DeepSea Power & Light (DSPL) for evaluation and repair using the RMA Procedure.

RMA Procedure for RepairShould it be necessary to return your light to the factory, follow the procedure for the Flooded Light Repair above, leaving the connector partially unscrewed. For warranty and non-warranty repairs please contact DeepSea Power & Light for a RMA number prior to returning your item. Please have your light model number, serial number and any other pertinent information along with a description of the problem, on hand when you call, or include them in a fax or e-mail. When shipping your item, be sure that the freight is pre-paid (CODs will not be accepted) and that the RMA number is clearly printed on the outside of the box.

All shipments should be sent to the address below:

DeepSea Power & LightAttn: RMA ####4033 Ruffin RoadSan Diego, CA 92123-1817U.S.A

Tel: (858) 576-1261Fax: 858-576-0219e-mail: [email protected]

Limited WarrantySeller warrants that the goods (except internal electronic components) sold under this contract will be free from defect in material and workmanship for a period of one year from the date of shipment from the factory, if they have been properly used. Internal electronic components are warranted for 90 days from the date of shipment from the factory, if they have been properly used. This warranty will be limited to the repair or replacement of parts and the necessary labor and services required to repair the goods. IT IS EXPRESS LY AGREED THAT THIS WARRANTY WILL BE IN LIEU OF ALL WARRANTIES OF FITNESS AND IN LIEU OF THE WARRANTY OF MERCHANTABILITY. This warranty is the exclusive and only warranty to pass with the goods under this contract. No agent, employee, or representative of the Seller has any authority to bind Seller to any information, representation, or warranty concerning the goods sold under this contract, and unless an affirmation, representation, or warranty made by an agent, employee, or representative is specifically included within this contract, it will not be enforceable by Buyer. If notice of defect is given to DeepSea Power & Light LLC within such 90 day or one year warranty period, the sole obligation of DeepSea Power & Light LLC shall be to furnish new or repaired parts free of charge in exchange for parts which have been proved defective and does not include any other costs such as the cost of removal of the defective part, installation, labor, or consequential damages of any kind, the exclusive remedy being to require DeepSea Power & Light LLC to furnish such new parts. Under no circumstances shall the Buyer be entitled to recover any incidental damages as that term is defined in Commercial Code §2715.

[email protected]

4033 Ruffin RoadSan Diego, CA 92123-1817 USA

T: (800) 487-3775F: (858) 576-0219

Page 6: SeaLite Lumos - deepsea.com · SeaLite® Lumos Operator’s Manual 4 tant This is the safety alert symbol It is used to alert you to potential personal inury haards. Obey all safety

SeaLite® Lumos Operator’s Manual

6

Appendix ADimming Response Curves

Page 7: SeaLite Lumos - deepsea.com · SeaLite® Lumos Operator’s Manual 4 tant This is the safety alert symbol It is used to alert you to potential personal inury haards. Obey all safety

SeaLite® LumosOperator’s Manual

7

0%

20%

40%

60%

80%

100%

0° 20° 40° 60° 80° 100° 120° 140° 160° 180°

% O

utpu

t

Input Phase Angle

SeaLite Lumos 1000 Phase Cut Dimming Response

SLL-1000 120VAC 60Hz SLL-1000 240VAC 50Hz

0%

20%

40%

60%

80%

100%

0V 20V 40V 60V 80V 100V 120V 140V 160V

% O

utpu

t

Input RMS Voltage

SeaLite Lumos 1000 Variable Voltage Dimming Response

SLL-1000 120VAC 60Hz SLL-1000 High Voltage DC

Page 8: SeaLite Lumos - deepsea.com · SeaLite® Lumos Operator’s Manual 4 tant This is the safety alert symbol It is used to alert you to potential personal inury haards. Obey all safety

SeaLite® Lumos Operator’s Manual

8

0%

20%

40%

60%

80%

100%

0.0V 1.0V 2.0V 3.0V 4.0V 5.0V 6.0V

% O

utpu

t

Dimming Input Voltage

SeaLite Lumos 2000 Analog Dimming Response

Page 9: SeaLite Lumos - deepsea.com · SeaLite® Lumos Operator’s Manual 4 tant This is the safety alert symbol It is used to alert you to potential personal inury haards. Obey all safety

SeaLite® LumosOperator’s Manual

9

Appendix BDriver Efficiency

Page 10: SeaLite Lumos - deepsea.com · SeaLite® Lumos Operator’s Manual 4 tant This is the safety alert symbol It is used to alert you to potential personal inury haards. Obey all safety

SeaLite® Lumos Operator’s Manual

10

0%

20%

40%

60%

80%

100%

60V 110V 160V 210V 260V 310V 360V

Effic

ienc

y

Input RMS Voltage

SeaLite Lumos 1000 Efficiency

SLL-1000 VAC 60Hz SLL-1000 VAC 50Hz SLL-1000 DC

0

0.5

1

1.5

2

2.5

3

3.5

0%

20%

40%

60%

80%

100%

6V 12V 18V 24V 30V 36V

Curr

ent (

A)

Effic

ienc

y

Input DC Voltage

SeaLite Lumos 2000 Efficiency

Efficiency Input Current

Page 11: SeaLite Lumos - deepsea.com · SeaLite® Lumos Operator’s Manual 4 tant This is the safety alert symbol It is used to alert you to potential personal inury haards. Obey all safety

SeaLite® LumosOperator’s Manual

11

Appendix CLow-Voltage DC Step Response Curve

Page 12: SeaLite Lumos - deepsea.com · SeaLite® Lumos Operator’s Manual 4 tant This is the safety alert symbol It is used to alert you to potential personal inury haards. Obey all safety

SeaLite® Lumos Operator’s Manual

12

0%

10%

20%

30%

40%

50%

60%

70%

80%

90%

100%

0V

1V

2V

3V

4V

5V

-10 0 10 20 30 40 50

% O

utpu

t

Cont

rol P

ulse

(V)

Time (ms)

SLL-2000 DIM Input Step Response Characteristics

Trigger % Output

Page 13: SeaLite Lumos - deepsea.com · SeaLite® Lumos Operator’s Manual 4 tant This is the safety alert symbol It is used to alert you to potential personal inury haards. Obey all safety

SeaLite® LumosOperator’s Manual

13

DIM Input Pulse Response: Rise Time SLL-2000 LVDC

DIM Input Pulse Response: Fall Time SLL-2000 LVDC

Page 14: SeaLite Lumos - deepsea.com · SeaLite® Lumos Operator’s Manual 4 tant This is the safety alert symbol It is used to alert you to potential personal inury haards. Obey all safety

SeaLite® Lumos Operator’s Manual

14

Appendix DBeam Patterns

Page 15: SeaLite Lumos - deepsea.com · SeaLite® Lumos Operator’s Manual 4 tant This is the safety alert symbol It is used to alert you to potential personal inury haards. Obey all safety

SeaLite® LumosOperator’s Manual

15

Lumens: Lumens:

Peak Lux: Peak Lux:

FWHP Angle: FWHP Angle:

NOTE: Beam pattern data for a representative sample of the indicated product configuration only.

87

18315160

341550

SeaLite Lumos SpotSLL-1000-DW-S-PV

SeaLite Lumos FloodSLL-2000-DW-F-A05

2607

0

1000

2000

3000

4000

5000

6000

-90-85 -80 -75

-70-65

-60-55

-50

-45

-40

-35

-30

-25

-20

-15

-10

-5

0

5

10

15

20

25

30

35

40

45

5055

6065

70758085

90

Radial Lux Intensity Comparison

-90.0°

-80.0°

-70.0°

-60.0°

-50.0°

-40.0°

-30.0°

-20.0°

-10.0°

0.0°

10.0°

20.0°

30.0°

40.0°

50.0°

60.0°

70.0°

80.0°

90.0°

0% 25% 50% 75% 100%

Degr

ees

% Output

Angular Distribution

Lux