Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

download Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

of 75

Transcript of Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    1/75

    ZTE

    SUBNETWORK_ID TEMPLATE_VERSION SDR_VERSION

    Sub Network ID Template VersionBase Station Soft

    Version

    INTEGER: 04095

    4.0.1 4.11.10.08P05

    75 , 1

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    2/75

    ZTE

    OP_SIGN BTS_NAME NE_ID NE_IP SDR_TYPE

    Operate Sign Site NameNetwork Element

    ID

    Network

    Element IP

    Address

    SDR Type

    P: No operate 80 characters at

    most

    INTEGER: 0 to 65535.

    Should be unique in the

    whole subnetwork.

    Index of all sheets.

    O&M IP of Node B,

    should be unique in

    the whole network.

    BS8700

    BS8900A

    BS8800 U120

    BS8800 U240

    BS8800 GU360

    BS8900 U240

    BS8900 GU360

    BS8906

    BS8800 U120A

    BS8908

    75 , 2

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    3/75

    ZTE

    RNC_ID BSC_ID LONGITUDE LATITUDE LOCATION

    RNC ID BSC ID Longitude Latitude Location

    INTEGER: 0 to 65535.

    GSM single-mode base

    station does not need to

    fill in.

    INTEGER: 0 to 65535.

    UMTS single-mode

    base station does not

    need to fill in.

    RANGE: -180 to 180.

    Accurate to six digits

    after the decimal point.

    RANGE: -90 to 90.

    Accurate to six digits

    after the decimal

    point.

    40 bytes at most,

    can be blank.

    75 , 3

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    4/75

    ZTE

    VENDOR_NAME USER_DEFINED_STATE

    Vendor Name User Defined State

    40 bytes at most,

    can be blank.

    80 bytes at most, can be

    blank.

    75 , 4

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    5/75

    NE_ID TELECOM_OPERATOR RADIO_MODE BBU_TYPE BBU_SLOT_1 BBU_SLOT_2

    Network Element

    IDTelecom Operator Radio Mode BBU Type BBU Slot 1 BBU Slot 2

    INTEGER: 0 to 65535.

    Should be unique in

    the whole subnetwork.

    Index of all sheets.

    127 bytes at most, without & ' "

    UMTS

    GSM

    GSM+UMTS

    BBU-2U

    BBU-3U

    DIET

    CC

    CCC

    UES

    TRB-G904

    TRB-G184

    CC

    CCC

    UES

    Keep empty or

    remove the column

    if there isn't a

    board.(It's applies

    to all BBU Slot)

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    6/75

    BBU_SLOT_3 BBU_SLOT_4 BBU_SLOT_5 BBU_SLOT_6 BBU_SLOT_7 BBU_SLOT_8

    BBU Slot 3 BBU Slot 4 BBU Slot 5 BBU Slot 6 BBU Slot 7 BBU Slot 8

    FS

    UBPG2

    BPL

    UBPG(only available in

    BBU-3U)

    FS

    BPC

    UBPG

    UBPG2

    TAM0

    TAM1

    TAM2

    BPL

    BPC

    UBPG

    BPK

    UBPG2

    SE

    UES

    TAM0

    TAM1

    TAM2

    USR1-A

    BPL

    BPC

    UBPG

    BPK

    UBPG2

    SE

    TAM0

    TAM1

    TAM2

    USR1-A

    BPL

    BPC

    UBPG

    BPK

    UBPG2

    SE

    TAM0

    TAM1

    TAM2

    USR1-A

    BPL

    BPC

    UBPG

    SE

    BPK

    UBPG2

    TAM0

    TAM1

    TAM2

    BPL

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    7/75

    BBU_SLOT_9 BBU_SLOT_10 BBU_SLO T_11 BBU_SLOT _12 BBU_SLOT_14 BBU_SLOT_15

    BBU Slot 9 BBU Slot 10 BBU Slot 11 BBU Slot 12 BBU Slot 14 BBU Slot 15

    UBPG

    only available in

    BBU-3U

    UBPG

    only available in

    BBU-3U

    UBPG

    only available in

    BBU-3U

    UBPG

    only available in

    BBU-3U

    PM

    SE(only available in

    BBU-3U)

    PM

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    8/75

    BBU_SLOT_16 BBU_SLOT_17 SHELF2_BBU_SLOT_1 SHELF2_BBU_SLOT_2 SHELF2_BBU_SLOT_3

    BBU Slot 16 BBU Slot 17Shelf 2's BBU Slot

    1

    Shelf 2's BBU Slot

    2

    Shelf 2's BBU Slot

    3

    PM

    only available in

    BBU-3U

    PM

    only available in

    BBU-3U

    CC

    CCC

    UES

    CC

    CCC

    UES

    FS

    UBPG2

    BPL

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    9/75

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    10/75

    SHELF2_BBU_SLOT_14 SHELF2_BBU_SLOT_15 RACK_TOPOLOGY FS3_OPTICAL_MODULE_TYPE

    Shelf 2's BBU Slot

    14

    Shelf 2's BBU Slot

    15Rack Topology

    Optical Module Type of

    FS in Slot 3

    PM PM Pattern:1-RU-RU-...,1-RU-RU-...

    For example, "1-2-3,1-4,1-51-52"

    means RSU2 and RSU4 and RRU51

    connect with the main rack, RSU3

    connects with RSU2, RRU52

    connects with RRU51. Keep blank if

    there is no cascade connection.

    1.25G

    2.5G

    3G

    6G

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    11/75

    FS4_OPTICAL_MODULE_TYPE

    Optical Module Type of

    FS in Slot 4

    1.25G

    2.5G

    3G

    6G

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    12/75

    NE_ID EPM_BOARD EPM_PWR_TYPE EPM_DEAL_MODE

    Network Element

    IDConnected Board Epm Power Type

    EPm Data Processing

    Mode

    INTEGER: 0 to 65535.

    Should be unique in the

    whole subnetwork.

    Index of all sheets.

    SA

    SE-SlotNo

    2-SA: SA in shelf 2

    2-SE-SlotNo: SE in shelf 2

    ZXDU58 B900

    ZXDU58 B121

    ZXDU68 B201

    ZXDU150

    ZXDU45

    ZXDU75ZXDU58 B121(V4.5)

    ZXDU68 W301

    ZXDU68 S301

    0:Transparent transmission,

    1:Parse

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    13/75

    NE_ID NT P_SE RV ER_IP TIME _ZONE SUMME R_TIME _STA RT SUMMER_T IME_E ND

    Network Element

    ID

    NTP Server IP

    AddressTime Zone Summer Time Start Summer Time End

    INTEGER: 0 to 65535.

    Should be unique in the

    whole subnetwork.

    Index of all sheets.

    IPV4 Pattern: MM-DD

    HH:mm.

    Fill in '0' if not used

    Pattern: MM-DD

    HH:mm.

    Fill in '0' if not used

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    14/75

    NE_ID CLOCK_PRIORITY CLOCK_TYPE CLOCK_SYNC_MODE GPS_CABLE_TYPE

    Network Element

    ID

    Clock Source

    Priority

    Clock Source

    Type

    Clock Synchronization

    ModeGPS Cable Type

    INTEGER: 0 to 65535.

    Should be unique in

    the whole subnetwork.

    Index of all sheets.

    INTEGER: 1 to 8 Internal GNSS

    External GNSS

    Cascade GNSS

    1PPS+TOD

    BITS-2MHz

    BITS-2Mbps

    Line

    1588

    SyncE

    0: GSM/UMTS Frequency

    Sync,

    1: GSM FrameNumber Sync.

    UMTS Frequency Sync,

    2: GSM Frequency Sync.

    UMTS FrameNumber Sync,

    3: GSM/UMTS FrameNumber

    Sync

    0: Multiplexing input

    1: Distribution input

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    15/75

    GPS_RECEIVER_TYPE GPS_CABLE_DELAY CLOCK_SSM

    GPS Receiver TypeLength of Cascade

    cable(m)Enable SSM

    1:GPS

    2:GLONASS

    3:GPS+GLONASS

    INTEGER: 0 to 15 Y:Yes

    N:No

    Must be configured if

    CLOCK_ID is SyncE

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    16/75

    NE_ID TAM_SHELF TAM_SLOT TAM_PORT

    Network Element

    ID

    TAM Board Shelf

    No.TAM Board Slot No. TAM Board Port No.

    INTEGER: 0 to 65535.

    Should be unique in

    the whole subnetwork.

    Index of all sheets.

    INTEGER: 1 to 2 INTEGER: 1 to 23 INTEGER: 0 to 5

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    17/75

    TAM_WORKING_CURRENT TAM_ALM_MODE

    Work Current ValuemA Alarm Detect ModeTAM0: 75 to 300

    TAM1: 75 to 400

    TAM2: 75 to 400

    Configure the maximum currentvalue of the specified port.

    0:currentDetect

    1:pulsewidthDetect

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    18/75

    ZTE

    NE_ID TRANSMISSION_TYPE TRANSMISSION_MEDIUM ETHERNET_WORK_MODE

    Network Element

    ID

    Transmission

    Type

    Transmission

    MediumEthernet Mode

    INTEGER: 0 to 65535.

    Should be unique in the

    whole subnetwork.

    Index of all sheets.

    IP

    ATM

    ATM+IP

    FE

    E1

    T1

    FE+E1

    FE+T1

    Auto

    1000M

    100M

    10M

    100M-Fiber

    75 , 18

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    19/75

    ZTE

    FE_BANDWIDTH FE_PHYLAYERPORTNO

    FE/GE

    BandWidth(kbps)

    FE/GE Physical Layer

    Port No.INTEGER:100 to 1000000.

    Step 100

    INTEGER: 0 to 17

    75 , 19

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    20/75

    NE_ID IP_NO IP_VLAN_ID IP_VLAN_IP_ADDR IP_VLAN_MASK

    Network Element

    IDIP No. IP Vlan No. IP Address IP Subnet Mask

    INTEGER: 0 to 65535.

    Should be unique in the

    whole subnetwork.

    Index of all sheets.

    INTEGER: 0 to 19 INTEGER: 1 to 4094.

    Keeping empty if it's

    invalid.

    IPV4 IPV4

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    21/75

    IP_VLAN_GATEWAY STATICROUTE_IPADDRESS STATICROUTE_NETWORKMASK STATICROUTE_NEXTHOP_IPADDR

    IP Gateway

    Address

    Static Route

    Destination IP Address

    Static Route Network

    Mask

    Static Route Next Hop IP

    AddressIPV4 IPV4

    can be blank.

    IPV4

    can be blank.

    IPV4

    can be blank.

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    22/75

    PATH_DOMAIN PPP_NO PPP_HDLC_NO PPP_IP_ADDRESS PPP_PROTOCOL

    Path Domain PPP No.PPP HDLC Link

    No.

    Base Station IP

    Address

    PPP

    Encapsulation

    INTEGER: 03

    255: Invalid

    UMTS multi-path

    parameter

    INTEGER: 0 to 7. ML-

    PPP: 0 to 2

    Pattern: hdlc No.,hdlc

    No.,...

    hdlc No.:0 to 15, 8

    links at most.

    IPV4.

    "0.0.0.0" represents

    automatic allocation.

    PPP

    ML-PPP

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    23/75

    PPP_COMPRESSION MP_HEAD MP_PRIORITY QOSMAP_NO

    Support IP compress

    or notMP Head MP Priority QosMap No.

    Y:support

    N:non-support

    PPP does not support IP

    compress.

    Long

    Short

    Invalid

    Valid when encapsulation

    type is ML-PPP.

    1

    2

    3

    4

    INVALID

    Valid when encapsulation

    type is ML-PPP.

    This field can not be

    configured. Do not

    modify it.

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    24/75

    NE_ID LINK_PRIORITY TRANS_TYPE IPCLK_SYNC_SERVER_IP

    Network Element

    IDLink Priority

    IP Clock Transmission

    Mode

    IP Address of 1588 Clock

    Sync Server

    INTEGER: 0 to 65535.

    Should be unique in

    the whole subnetwork.

    Index of all sheets.

    INTEGER: 1 to 32 0:Multicast

    1:Unicast

    default:1

    Must be configured for IP 1588

    clock reference source(GIPI

    interface IP). Valid only when it is

    IP over Ethernet transmission type.

    If there are two or more 1588

    servers, configure it as this:

    "IP1;IP2;...", with four IP addresses

    at most.

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    25/75

    IPCLK_IP_NO

    IP Link No. of 1588

    Clock Sync Channel

    INTEGER: 0 to 19

    Existed in IP sheet.

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    26/75

    NE_ID E1T1_PHYLAYERPORT_NO E1T1_SHELF E1T1_BOARD

    Network Element

    ID

    E1/T1 Physical Layer

    Port No.E1T1 Board Shelf No. E1T1 Board Type

    INTEGER: 0 to 65535.

    Should be unique in the

    whole subnetwork.

    Index of all sheets.

    INTEGER: 0 to 17 INTEGER: 1 to 2 SA

    SE-5

    SE-14

    TRB Series.

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    27/75

    E1T1_PORT

    E1/T1 Port No.

    INTEGER: 0 to 7

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    28/75

    ZTE

    NE_ID HDLC_NO HDLC_E1T 1_PHYLAYERP ORT_NO HDLC_T IMESLOT_MA P

    Network Element

    IDHDLC Link No.

    E1/T1 Physical Layer Port

    No.HDLC Timeslot

    INTEGER: 0 to 65535.

    Should be unique in the

    whole subnetwork.

    Index of all sheets.

    INTEGER: 0 to 15 INTEGER: 0 to 17

    Must be existed in E1T1 sheet

    Pattern:start of time slot-end

    of time slot,...

    Slot 1 to 31(T1 is 24) can be

    used.

    Slot 0 is excluded.

    Default: 1-31

    75 , 28

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    29/75

    ZTE

    TSI_IN_TIMESLOT_MAP TSI_OUT_PHYLAYERPORT_NO TSI_OUT_TIMESLOT_MAP TSI_OUT_NO

    TSI In TimeslotTSI Out Physical Layer

    Port No.TSI Out Timeslot TSI Out No.

    The pattern is same as HDLC

    timeslot. can not overlap with

    the HDLC timeslot. should be

    filled in case of time slot

    interchange, otherwise

    keeping empty.

    INTEGER: 0 to 17.

    Should be filled in case of time slot

    interchange, otherwise keeping

    empty.

    The pattern is same as HDLC

    timeslot. The number of out&in

    timeslot must be identical.

    should be filled in case of time

    slot interchange, otherwise

    keeping empty.

    This field can not

    be configured. Do

    not modify it.

    75 , 29

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    30/75

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    31/75

    ZTE

    SCTP_REMOTE_IP SCTP_IP_NO SCTP_INOUT_STREAM SCTP_QOS

    SCTP Remote IP

    Address

    IP No. of SCTP

    Channel

    Number of SCTP in-

    and-out StreamsSCTP QOS

    IPV4 INTEGER: 0 to 19

    Existed in IP sheet.

    Integer: 2 to 6 Integer: 0 to 63

    IP service model

    configuration. You can

    choose different model

    according to the actual

    scenario.

    75 , 31

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    32/75

    ZTE

    NE_ID A TM_E 1T1_P HYLAYE RPORT _NO AT M_ADDRESS

    Network Element

    ID

    ATM E1/T1 Physical Layer Port

    No.ATM Address

    INTEGER: 0 to 65535.

    Should be unique in the

    whole subnetwork.

    Index of all sheets.

    Pattern: portNo,portNo,..

    portNo:0 to 17.

    Must be existed in E1T1 sheet

    Pattern: dec.dec

    Keep blank if not used

    75 , 32

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    33/75

    ZTE

    NE_ID OMC_CHANNEL_NO OMCB_GATEWAY_IP OMCB_IP_NO OMC_SERVER_IP

    Network Element

    ID

    OMC Channel

    Link No.

    OMC Gateway IP

    Address

    OMC Used IP

    No.

    OMC Server IP

    AddressINTEGER: 0 to 65535.

    Should be unique in the

    whole subnetwork.

    Index of all sheets.

    Integer: 0 to 2 IPV4 INTEGER: 0 to 19

    Existed in IP sheet.

    IPV4

    75 , 33

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    34/75

    ZTE

    INNER_IP OMCB_QOS

    SDR inner ip

    address

    Operation and Maintenance

    Gateway QoSIPV4 Integer: 0 to 63

    The transmission quality priority of

    O&M packet. It is set by the user. It is

    recommendedto set it to "46:EF

    service, accelerated forwarding,

    minimum delay, and maximum flow".

    75 , 34

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    35/75

    ZTE

    NE_ID RRU_NAME RU_NO BOARD_TYPE FS_PORT

    Network Element

    IDRRU Name RU No. Board Type

    Previous Hop Optical

    Port

    INTEGER: 0 to 65535.

    Should be unique in thewhole subnetwork.

    Index of all sheets.

    60 characters at

    most, can be blank.

    without< > & ' "

    RSU: 2 to 50

    RRU: 51 to 201

    Shelf 1's FS-3: 0 to 5

    Shelf 1's FS-4: 20 to 25

    Shelf 1's UBPG2-3: 0 to 2Shelf 1's UBPG2-4: 20 to 22

    Shelf 1's UBPG2-8: 80 to 82

    Shelf 2's FS-3: 1015

    Shelf 2's FS-4: 3035

    Shelf 2's UBPG2-3: 1012

    Shelf 2's UBPG2-4: 3032

    Shelf 2's UBPG2-8: 8587

    Only GSM BTS can use

    UBPG2 as parent topo.

    75 , 35

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    36/75

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    37/75

    ZTE

    UPPER_RESUME_LIMI

    T

    Alarm Recovery

    Upper Limit of

    VSWR

    Integer

    75 , 37

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    38/75

    ZTE

    NE_ID FCE_RACK_NO C TRL_A UX_CABINE T_NO

    Network Element

    IDFCE Rack No

    Controlled auxiliary

    cabinet No.INTEGER: 0 to 65535.

    Should be unique in the

    whole subnetwork.

    Index of all sheets.

    2 to 50

    119 to 123: FCE in 1-1-

    19 to 1-1-23

    Fill out the attribute for the

    FCE in an auxiliary cabinet,

    Can not be duplicate.

    75 , 38

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    39/75

    NE_ID RU_NO PADEV_NO RADIO_MODE TRANSMIT_FREQ

    Network Element

    IDRU No. PA Device No. Radio Mode

    Central Downlink

    Frequency(MHz)

    INTEGER: 0 to 65535.

    Should be unique in

    the whole subnetwork.

    Index of all sheets.

    RSU: 2 to 50

    RRU: 51 to 201

    INTEGER: 1 to 3

    The second PA is 2,

    The third PA is 3

    UMTS

    GSM

    GSM+UMTS

    Multiple of 0.2MHz. 0 or

    blank represents

    automatical calculation by

    Node B

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    40/75

    DETECT_SWITCH

    Primary Diversity

    Balance Detection

    N:disenable

    Y:enable

    default:N

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    41/75

    NE_ID RU_NO RX_PORT_NO RECEIVE_FREQ RX_EXTENSION_RU

    Network Element

    IDRU No. Rx Port ID

    Central Uplink

    Frequency(MHz)Rx RF Extension RU No.

    INTEGER: 0 to 65535.

    Should be unique in

    the whole subnetwork.

    Index of all sheets.

    RSU: 2 to 50

    RRU: 51 to 201

    INTEGER: 1 to 6

    Default: 1

    Multiple of 0.2MHz. 0 or

    blank represents automaticalcalculation by Node B. When

    downlink frequency is not 0,

    uplink frequency should not

    be 0.

    The frequency band of

    associated RU should beidentical. Each RU can only be

    associated once.

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    42/75

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    43/75

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    44/75

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    45/75

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    46/75

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    47/75

    TX_POWER_GAIN TMA_NOISE ANT_NO RET_NO

    ower op

    Amplifier

    Downlink Power

    ower op

    Amplifier Noise

    Coefficient(0.1d

    Connected

    Mechanical

    Antenna RDN

    Connected

    RET Antenna

    RDN

    INTEGER:70 to 170

    Invalid:255

    INTEGER: 10 to 30

    Invalid:255

    This field can not

    be configured. Donot modify it.

    This field can not

    be configured. Donot modify it.

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    48/75

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    49/75

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    50/75

    ZTE

    NE_ID GRU_NO GU_CONFIG_MODE CARRIER_GROUP CARRIER_NUMBER

    Network Element

    IDGSM RU No.

    GU Carrier Config

    ModeCarrier Group

    Total Carrier

    Number

    INTEGER: 0 to 65535.

    Should be unique in the

    whole subnetwork.

    Index of all sheets.

    RSU: 2 to 50

    RRU: 51 to 201

    The second PA of

    R8882RSU82

    is:'RU No.#2'

    4G+1U

    2G+2U

    Invalid

    Single radio mode is

    Invalid.

    INTEGER: 0 to 32.

    0:Do not group

    DTR:1 to 6

    TTR:1 to 2

    RSU82:1 to 6

    R8882: 1 to 6

    75 , 50

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    51/75

    ZTE

    CARRIER_POWER_PARA STATIC_POWER_LEVEL CELL_ID_1 TRX_NUMBER_1 CELL_ID_2

    Carrier Power(W)Static Power

    Level(db)

    First GSM Cell

    No.

    Carrier Number

    dedicated to first

    sector

    Second GSM

    Cell No.

    INTEGER: 1 to 80 0db, 2db, 4db, 6db, 8db,

    10db, 12db, 14db, 16db,

    18db, 20db, -0.2db, -0.4db,

    -0.6db, -0.8db, -1.0db, -

    1.2db

    INTEGER: 1 to 54 INTEGER: 1 to 6

    The sum total of all

    sector's carrier number is

    not greater than the Total

    Carrier Number.

    INTEGER: 1 to 54

    255: Invalid

    75 , 51

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    52/75

    ZTE

    TRX_NUMBER_2 CELL_ID_3 TRX_NUMBER_3 CELL_ID_4 TRX_NUMBER_4

    Carrier Number

    dedicated to

    second sector

    Third GSM Cell

    No.

    Carrier Number

    dedicated to third

    sector

    Fourth GSM Cell

    No.

    Carrier Number

    dedicated to

    fourth sector

    INTEGER: 1 to 6

    The sum total of all

    sector's carrier number

    is not greater than the

    Total Carrier Number.

    INTEGER: 1 to 54 INTEGER: 1 to 6

    The sum total of all

    sector's carrier number is

    not greater than the Total

    Carrier Number.

    INTEGER: 1 to 54

    255: Invalid

    INTEGER: 1 to 6

    The sum total of all

    sector's carrier number

    is not greater than the

    Total Carrier Number.

    75 , 52

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    53/75

    ZTE

    CELL_ID_5 TRX_NUMBER_5 CELL_ID_6 TRX_NUMBER_6 SUB_FREQ_BAND

    Fifth GSM Cell

    No.

    Carrier Number

    dedicated to fifth

    sector

    Sixth GSM Cell

    No.

    Carrier Number

    dedicated to sixth

    sector

    Branch

    Frequence

    Band

    INTEGER: 1 to 54 INTEGER: 1 to 6

    The sum total of all

    sector's carrier number is

    not greater than the Total

    Carrier Number.

    INTEGER: 1 to 54

    255: Invalid

    INTEGER: 1 to 6

    The sum total of all

    sector's carrier number

    is not greater than the

    Total Carrier Number.

    INTEGER: 1 to 3.

    255: Invalid

    75 , 53

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    54/75

    ZTE

    TX_MODE RX_MODE DDT_OFFSET GSM_RX_CONFIG

    Tx Mode Rx Mode DDT delay

    GSM primary-

    secondary antenna

    receiving setting

    0:Normal mode

    1:DPCT

    2:DDT

    3:Antenna hopping

    RU02: series:0 to 3,

    RSU82/R8882:{0,2,3}.

    Other RU types should be

    blank.

    Default:0

    0:2-antenna diversity

    reception

    1:4-antenna diversity

    reception

    2:Cross diversity reception

    TTR/GRSU series:0 to 1

    RSU82:0 to 2

    Other RU types should be

    blank.

    Default:0

    INTEGER: 0 to 8.

    Be valid when tx mode is

    DDT.

    Default:0

    0:Primary and secondary

    antenna receiving,

    1:Primary antenna receiving.

    secondary antenna not

    receiving,

    2:Secondary antenna receiving.

    primary antenna not receiving

    75 , 54

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    55/75

    ZTE

    GSM_NO

    GSM Cell

    Channel

    Resource No.

    This field can not be

    configured. Do not

    modify it.

    75 , 55

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    56/75

    ZTE

    NE_ID NODEB_ID CE_UP CE_DOWN DYNAMIC_POWER_TRACK

    Network Element

    IDNodeB ID CE Up CE Down

    RU Dynamic Power

    TrackINTEGER: 0 to 65535.

    Should be unique in the

    whole subnetwork.

    Index of all sheets.

    INTEGER: 0 to 65535.

    Same as NE ID if radio

    mode is UMTS.

    INTEGER: 1 to 1920

    65535:Invalid

    INTEGER: 1 to 1920

    65535:Invalid

    Y: Function opened

    N: Function closed

    75 , 56

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    57/75

    ZTE

    PASHARE_PER

    Power-sharing Ratio

    INTEGER: 0 to 50

    75 , 57

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    58/75

    ZTE

    NE_ID UMTS_SECTOR_ID UMTS_SECTOR_INFO RELATED_RU RX_TYPE

    Network Element

    IDSector No.

    Sector

    InformationRelated RU Rx Type

    INTEGER: 0 to 65535.

    Should be unique in the

    whole subnetwork.

    Index of all sheets.

    INTEGER: 0 to 255 199 bytes at most, can

    be blank. Without < >

    & ' "

    RU Units belong to this

    sector.

    Pattern: RU No.&RU

    No.&

    The second PA of RU

    is:'RU No.#2'

    Y: Diversity

    N: No Diversity

    MIMO

    75 , 58

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    59/75

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    60/75

    ZTE

    NE_ID LOCAL_CELL_INFO LOCAL_CELL_ID BP_BOARD

    Network Element

    ID

    Local Cell

    InformationLocal Cell ID BP Board

    INTEGER: 0 to 65535.

    Should be unique in the

    whole subnetwork.

    Index of all sheets.

    199 bytes at most, can

    be blank. without < > &

    ' "

    INTEGER: 0 to 268435455.

    Unique in the network.

    Fill in BPC and BPK's slot

    number.

    Pattern: BPSlot&BPSlot&

    Plus 20 for slot number of

    shelf 2's BP board.

    75 , 60

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    61/75

    ZTE

    TOASSIGN_BASEBAND_RESOUR UMTS_SECTOR_ID TRANSMITTING_FREQ FREQ_SPACING

    Automatically assign

    baseband resource or notSector No.

    Transmitting

    Frequency(MHz)

    Receive Filter

    BandWidthY

    N

    Refers to the sheet

    "UMTS Sector"

    Multiple of 0.2MHz.

    869 to 894

    925 to 960

    1805 to 1880

    1930 to 1990

    2110 to 2170

    5M

    4.8M

    4.6M

    4.4M

    4.2M

    75 , 61

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    62/75

    ZTE

    CELL_RADIUS TRANSMIT_OFFSET RECEIVE_OFFSET LOCAL_CELL_POWER SUPPORT_SPEED

    Cell RadiusTransmit Delay

    Offset(chip)

    receive Delay

    Offset(chip)Local Cell Power(W)

    Mobile Speed

    Supported by Cell2.5km

    5km

    10km

    20km

    40km

    80km

    120km

    240km

    Integer: -63 to 63 Integer: -63 to 63 INTEGER: 1 to 200

    255:Invalid

    0:0-250km/h

    1:250-350km/h

    75 , 62

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    63/75

    ZTE

    COVERAGE_T YPE DC_LOCAL_CE LL BAT TE RY_SAV ING LOCAL_CELL_ 2MS_GA IN

    Coverage TypeDual Carrier Secondary

    Local Cell

    Electric-saving

    Mode2ms Gain

    0:Indoor

    1:Outdoor

    Primary and secondary local cell must

    belong to the same sector, and is

    neighboring cells(transmission

    frequency interval is between 4.2 and

    5MHz)

    Y:Function opened

    N:Function closed

    Enable:support

    Disable:non-support

    75 , 63

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    64/75

    ZTE

    LOCAL_CELL_VAM ENHANCED_VAM

    VAM FunctionEnable E-VAM

    function or notY:support

    N:non-support

    It can be set as "Y"

    only when Rx type of

    affiliated sector is

    MIMO.

    YEnable

    NDisable

    In the case of vamEnable

    being Y, it decide whether

    to enable E-VAM function.

    75 , 64

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    65/75

    NE_ID CELL_ID GPS_OFFSET POINT1_RU_NO

    Network Element

    IDCell No.

    GPS Synchronous

    Frame Header Offset

    High speed railway cell

    entry point 1 RU No.

    INTEGER: 0 to 65535.

    Should be unique inthe whole subnetwork.

    Index of all sheets.

    INTEGER: 1 to

    54

    INTEGER: 0 to 50 The second PA of

    R8882RSU82 is:'RU

    No.#2'. Can be blank

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    66/75

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    67/75

    ZTE

    NE_ID CELL_ID TRX_NO CHANNEL_MODE CARRIER_GROUP

    Network Element

    IDCell No.

    Logic Carrier

    Frequency No.Channel Mode Carrier Group

    INTEGER: 0 to 65535.

    Should be unique in the

    whole subnetwork.

    Index of all sheets.

    INTEGER: 1 to 54 INTEGER: 1 to 60 0:Single carrier

    1:Dual carrier

    2:Multi carrier

    INTEGER: 0 to 32.

    0:Do not group

    75 , 67

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    68/75

    ZTE

    FREQ_BAND SUB_FREQ_BAND USE_IRC EXTENSION_CARRIER MCUM_RX_SEL_MODE

    Frequency

    Band

    Branch Frequence

    Band

    Use IRC or

    Not

    Extend Carrier

    Frequency or Not

    Is uplink signal

    selected

    according to CIR

    2.1G

    1900M

    1800M

    850M

    900M

    INTEGER: 1 to 3.

    255: Invalid

    0:Disable IRC

    1:Enable IRC

    2:Enable STIRC

    Y:Yes

    N:No

    Y:Yes

    N:No

    default:N

    75 , 68

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    69/75

    ZTE

    MCUM_TX_SEL_MODE

    Select RU

    transmission or not

    Y:Yes

    N:No

    default:N

    75 , 69

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    70/75

    ZTE

    NE_ID DRY_CONTACT_POSITION DRY_CONTACT_NO

    Network Element

    IDDry Contact Position Dry Contact No.

    INTEGER: 0 to 65535.

    Should be unique in the

    whole subnetwork.

    Index of all sheets.

    SA

    SE-SlotNo

    2-SA: SA in shelf 2

    2-SE-SlotNo: SE in shelf 2

    FCE (1-1-18)

    FCE-RackNo

    If position is RU, the pattern is RU-No.,

    example:RU-51.

    The boards that support dry

    contact alarms are SA, FCE

    boards, and radio frequency

    boards.

    75 , 70

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    71/75

    ZTE

    DRY_CONTACT _USERLAB EL DRY_CONTACT _TYPE DRY_CONT ACT _CONTE NT

    User Label Dry Contact Type Dry Contact Alarm Code

    128 bytes at most, can be blank. Input:Input dry contact

    Output:Output dry contact

    Output dry contact should be

    linked to contact No.6 or 7 of

    SA/SE.

    198092044:Cabinet door alarm

    198092045:Flood detected

    198092046:Smoke detected

    198092047:Infrared alarm

    198092048:Air-condition fault

    198092049:Lightning protection box alarm

    198092051:PSU alarm

    198092052:PSU fan alarm

    198092068:Main power supply has a fault alarm

    198092206:Battery Fault,

    198092207:AC power-cut alarm,

    198092208:Rectifier alarm,

    198092209:Thermoelectric cooling alarm,

    198092259:Battery in low-voltage alarm,

    198092260:External device fault connected via dry

    75 , 71

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    72/75

    ZTE

    ALARM_STATUS OUT_CONTACT_TYPE

    Dry Contact Alarm

    Status

    Output Dry Contact

    StatusValid only if type is input.

    OPEN:Alarm appears if

    contact is open

    CLOSE:Alarm appears if

    contact is closed

    Valid only if type is output.

    0:Output low level

    1:Output high level

    75 , 72

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    73/75

    NE_ID AISG_RU_NO UNIQUE_ID DEV_TYPE VENDOR_CODE

    Network Element

    IDCCU Rack No.

    Device Serial

    NumberDevice Type Vendor Code

    INTEGER: 0 to 65535.

    Should be unique in the

    whole subnetwork.

    Index of all sheets.

    RSU2 to 50

    RRU51 to 201

    Existed in RU sheet.

    32 bytes at most RETC

    MULTI_RET

    ATMA

    MULTI_TMA

    ACOM

    AETMANSNRET

    LGPTMA

    127 bytes at most

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    74/75

    AISG_VERSION RET_RU_NO RET_PORT_NO AISG_TMA_NO

    AISG VersionConnected RET Device

    RU No

    Connected RET Device

    Port No

    Connected TMA

    Device No.

    1.1

    2.0

    RSU: 2 to 50

    RRU: 51 to 201

    Existed in RxDevice sheet and

    ANTENNA_TYPE must be

    RET. It indicatesAISG_TMA_NO bearer.

    INTEGER: 1 to 6

    Existed in RxDevice sheet and

    ANTENNA_TYPE must be

    RET. It indicates

    AISG_TMA_NO bearer.

    INTEGER: 1 to 96

    Existed in RxDevice

    sheet. Indicates

    RET_RU_NO and

    RET_PORT_NObearer.

  • 8/12/2019 Sdr(Gu) 4.11 Cm Negotiation Template v4.11.10.08p05

    75/75

    MULTI_ANT_NO AISG_USERLABEL FATHER_PORT SELF_PORT

    Subunits No.Description of Self-

    defined FieldSuperior Channel Local Channel

    INTEGER: 1 to 4

    255:Invalid

    The antenna number of AISG1.1

    and AISG2.0 Single RET

    decives is invalid. A subunit No.of other AISG2.0 devices

    corresponds to an AISG that can

    be controlled independently.

    128 bytes at most, can be

    blank. Without& ' " < > #

    % / \ ? @ : ,

    INTEGER: 0 to 12

    Used for SDTMA

    device of NSN private

    protocol. The value for

    other devices is 0.

    INTEGER: 0 to 12

    Used for SDTMA

    device of NSN private

    protocol. The value for

    other devices is 0.