Scurlock Industries Industries Jonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR...

43
Our Company was established in 1953 in Jonesboro, Arkansas, for the purpose of manu- facturing small diameter sewer pipe. Our history of steady growth in both product lines and manufacturing facilities has positioned us as a leader in the concrete products industry. Our companies have the ability to produce almost any precast concrete product while supporting that function with an engineering and quality control staff. Miami, OK Fayetteville, AR Springfield, MO Jonesboro, AR Introduction Scurlock I Scurlock I Scurlock I Scurlock I Scurlock Industries ndustries ndustries ndustries ndustries Scurlock I Scurlock I Scurlock I Scurlock I Scurlock Industries ndustries ndustries ndustries ndustries

Transcript of Scurlock Industries Industries Jonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR...

Our Company was established in 1953 inJonesboro, Arkansas, for the purpose of manu-facturing small diameter sewer pipe. Our history

of steady growth in both product lines andmanufacturing facilities has positioned us as aleader in the concrete products industry. Ourcompanies have the ability to produce almostany precast concrete product while supportingthat function with an engineering and quality

control staff.

Miami, OK

Fayetteville, AR

Springfield, MO

Jonesboro, AR

Introduction

Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesScurlock IScurlock IScurlock IScurlock IScurlock Industriesndustriesndustriesndustriesndustries

Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR

870-935-5913 417-862-5088 918-542-1884 479-521-0504

I. Reinforced Concrete Pipe.

A. Scope of Work. The work shall consist of furnishing all labor, materials, andequipment for the complete installation of storm sewer pipe, in conformance withthe lines and grades shown on the plans or as established by the Engineer.Items of work or materials not specifically mentioned but necessary for thecompletion of storm sewer line construction shall be considered as incidentalto the items in the contract.

B. Materials.a) Pipe. Pipe shall be of the type, size, and class shown on the plans.

b) Reinforced Concrete Culvert Pipe. Reinforced concrete culvert pipeshall conform to the requirements of the Specifications for ReinforcedConcrete Culvert Pipe, ASTM C-76. Installations shall be made withcircular pipe conforming to the requirements for class III, class IV, orclass V, B-Wall, or C-Wall, of the ASTM C-76 specification.

c) All precast flared end sections shall conform to ASTM C-76. Toe wallsrequired shall conform to AASHTO M-170.1) All precast Bends, Wyes, and Tees shall comply with ASTM C-76,

AASHTO M-170 or Federal Specification SS-P-375.

d) Fine and coarse aggregates for the concrete mixture shall comply with therequirements of ASTM specifications.1) Cement shall comply with the requirements of ASTM C-150.2) Steel shall comply with the requirements ASTM C-185.3) Joint sealing material, plastic type, shall comply with ASTM

C-990, AASHTO M-198, or Federal Specification SS-S-210A.

e) D-load design pipe shall conform to ASTM C-655.

f) Preform tape-type plastic compound shall be applied in accordance with themanufacturer’s recommendations.

Standard Storm Sewer Specifications for Culverts

Circular Pipe ASTM C-76

Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR

870-935-5913 417-862-5088 918-542-1884 479-521-0504

“A”InsideDia.

“B”Outside

Dia.

“C”Wall

Thickness

“D”Joint

LengthWaterway

AreaWeight

Per Foot

BulkCompound

Lbs. Per Joint

PreformedJt. Material

in Ft.

12”15”18”21”24”30”30”36”42”48”54”60”66”72”78”84”96”

120”

16”19 - 1/2”

23”26 - 1/2”

30”38 - 1/2”37 - 1/4”45 - 1/2”52 - 1/2”59 - 1/2”66 - 1/2”73 - 1/2”80 - 1/2”

86”93”

100”114”140”

4’ & 6’4’ & 6’

4’, 6’, 7-1/2’4’ & 6’

4’, 6’, 7-1/2’4’ & 7-1/2’

4’ & 6’4’ & 7-1/2’4’ & 7-1/2’4’ & 7-1/2’

7-1/2’4’ & 7-1/2’

7-1/2’4’, 7-1/2’ & 8’

8’7-1/2’

4’4’

B 2”B 2-1/4”B 2-1/2”B 2-3/4”

B 3”C 4-1/4”B 3-3/4”C 4-3/4”C 5-1/4”C 5-3/4”C 6-1/4”C 6-3/4”C 7-1/4”

B 7”B 7-1/2”

B 8”B 9”A 10”

.79 sf.1.23 sf.1.77 sf.2.41 sf.3.14 sf.4.91 sf.4.91 sf.7.07 sf.9.62 sf.

12.57 sf.15.90 sf.19.64 sf.23.76 sf.28.28 sf.33.18 sf.38.47 sf.50.27 sf.78.54 sf.

95 lbs.127 lbs.168 lbs.214 lbs.264 lbs.476 lbs.400 lbs.654 lbs.811 lbs.

1011 lbs.1230 lbs.1477 lbs.1735 lbs.1811 lbs.2100 lbs.2410 lbs.3090 lbs.4263 lbs.

1.622.774.006.107.80

10.0010.0018.7

28.5029.0045.0059.0076.0093.0095.00

137.00195.00255.00

3.204.004.905.506.258.008.009.50

11.0012.6014.2015.7517.2518.9020.5022.0025.2031.50

Class III =Class IV =Class V =

1350 lbs.2000 lbs.3000 lbs.

2000 lbs.3000 lbs.3750 lbs.

NOTE: All circular pipe can be furnished in ClassIII, IV, and V, or special designs. Contact our plantfor Class I or Class II products

ASTM C - 76 Pipe Data

InitialD-Load

Ulitmate Load

Circular Pipe

Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR

870-935-5913 417-862-5088 918-542-1884 479-521-0504

Reinforced Concrete Culvert Pipe complies withASTM C-76

I.D.

End View Side View

tongue

grooveMortar Joint

Pipe Joint Area

c

c

a b

d

NOTE:All Circular pipe can be furnished in Class III, IV, V or Special design D-load.

Class III =Class IV =Class V =

1350 lbs.2000 lbs.3000 lbs.

2000 lbs.3000 lbs.3750 lbs.

Initial D-Load

Ultimate Load

Contact our plant for Class I or Class II products

C-76 Mortar Joint BendCulvert Pipe

Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR

870-935-5913 417-862-5088 918-542-1884 479-521-0504

Typical fitting made from astandard piece of pipe. Pipemanufactured to meet ASTM C-76specifications, including reinforce-ment for Class III, IV or V.

NOTE: Reinforcement in both pieces to be weldedtogether at time of construction.

C & D Approximately 1/2 length of pipe less loss due to cut.

12” thru 24” 4 ft. pipe joints30” thru 72” 7.5 ft. pipe joints

A RCP Inside DiameterB RCP Outside Diameter

A B

C

D

Variable0 degrees to90 degrees

• Contact our plant for all confirmations on RCP Bend sizes.

Flared End Section

Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR

870-935-5913 417-862-5088 918-542-1884 479-521-0504

Dia.

12”15”18”21”24”27”30”36”42”48”54”60”66”72”84”

Wall

2”2-1/4”2-1/2”2-3/4”

3”3-1/4”3-1/2”

4”4-1/2”

5”5-1/2”

6”6-1/2”

7”

Weight

530 lbs.750 lbs.990 lbs.1284 lbs.1520 lbs.1855 lbs.2190 lbs.4100 lbs.5380 lbs.6550 lbs.8040 lbs.8750 lbs.9400 lbs.

12,520 lbs.

A

4”6”9”9”

9-1/2”10-1/2”

1’0”1’3”1’9”2’0”2’3”2’6”2’0”2’0”

B Min.

4’0”3’10”3’10”3’2”2’6”2’1”1’7”2’10”2’11”2’2”2’11”3’3”1’9”1’9”

C Min.

6’6’6’6’6’6’6’8’8’8’8’8’8’

8’3”

D

2’0”2’6”3’0”3’6”4’0”4’6”5’0”6’0”6’6”7’0”7’6”8’0”8’6”9’0”

E

18”18”18”18”24”24”24”24”24”24”36”36”36”42”

Layer of Grout betweenEnd Section and Toe Wall

WallPlus 6”

D

Diameter

Toe Wall Constructedat Outlet End Only

WallB

C

8”

Wall

Dimensions

Contact our plant for details

NOTE:All flared ends are manufactured to ASTM specifications and state highway stan-dards

A

Bell or Spigot as required

E

Precast Flared Ends

Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR

870-935-5913 417-862-5088 918-542-1884 479-521-0504

12151821242730364248546066

0.070.070.070.070.070.130.140.120.150.180.220.250.31

0.090.120.140.160.190.23

0.070.070.070.110.120.130.170.200.240.280.34

0.0480.0540.0600.0660.0720.0780.0840.0960.1080.1200.1320.1440.156

0.0480.0540.0600.0660.0720.0780.0840.0960.1080.1200.1320.1440.156

AdjoiningPipe Dia.Inches

InnerCage

Sq. In./Lin. Ft.

OuterCage

Sq. In./Lin. Ft.

Circular

Barrel SectionReinforcement

Elliptical

Flare SectionReinforcement(one layer only

in center of wall)Area of

LongitudinalSq. In./Lin. Ft.

Area ofTransverse

Sq. In./Lin. Ft.

STATE-APPROVED Flared Ends available 12” thru 84”

Reinforcement

Typical Pipe Installations

Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR

870-935-5913 417-862-5088 918-542-1884 479-521-0504

ASTM C-76Class 560” RCP

8

Horizontal Elliptical Pipe

Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR

870-935-5913 417-862-5088 918-542-1884 479-521-0504

EquivalentRoundSize

Rise & SpanInside

Diameter

Classification(UltimateStrength)

WallThickness

Weight(PerFt.)

Area(Sq.Ft.)

Length(Pipe

Section)

Outside Diameter(O.D.)

Vertical Horizontal

18”

24”

30”

36”

42”

48”

54”

60”

14” x 23”

19” x 30”

24” x 38”

29” x 45”

34” x 53”

38” x 60”

43” x 68”

48” x 76”

C-2, C-3, C-4

C-2, C-3, C-4

C-2, C-3, C-4

C-2, C-3, C-4

C-2, C-3, C-4

C-2, C-3, - -

C-2, C-3, - -

C-2, C-3, - -

2-3/4”

3-1/4”

3-3/4”

4-1/2”

5”

5-1/2”

6”

6-1/24”

200 lbs.

300 lbs.

430 lbs.

625 lbs.

815 lbs.

1000 lbs.

1235 lbs.

1475 lbs.

1.8

3.3

5.1

7.4

10.2

12.9

16.6

20.5

7.5’

7.5’

7.5’

7.5’

7.5’

7.5’

6’

5’

19-1/2”

25-1/2”

31-1/2”

38”

44”

49”

55”

61”

28-1/2”

36-1/2”

45-1/2”

54”

63”

71”

80”

89”

18” HE RCP through 36” HE RCP is available 7-1/2’ joints.

Span

Rise

End View

Length

Wall

Side View

Reinf.

tongue

grooveMortar Joint

Pipe Joint Area

Reinforced Concrete Culvert Pipe complies with ASTM C - 507

Contact our plant for Special Design D-Load HE products that are available

Elliptical RCP

Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR

870-935-5913 417-862-5088 918-542-1884 479-521-0504

Rise& Span

RoundEquiv.

JointLength

Weight(lbs.)

14” x 23”

19” x 30”

24” x 38”

29” x 45”

34” x 53”

38” x 60”

43” x 68”

48” x 76”

18”

24”

30”

36”

42”

48”

54”

60”

7 1/2’

7 1/2’

7 1/2’

7 1/2’

7 1/2’

7 1/2’

6’

5’

1500 lbs.

1680 lbs.

2280 lbs.

3380 lbs.

4480 lbs.

5580 lbs.

6880 lbs.

6980 lbs.

24 “ through 36” End Section available in 7 - 1/2’ lengths.

Span

Rise

midline of HE RCP upstream shown

Available in upstream and downstream tapered end sections in the following sizes:

Tapered End SectionsASTM C-507

Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR

870-935-5913 417-862-5088 918-542-1884 479-521-0504

Standard SpecificationsSanitary Sewer Pipe

Reinforced Concrete Pipe:A. General. Reinforced concrete pipe shall be precast and shall conform to the

requirements of The Standard Specifications for Reinforced Concrete Low-HeadPressure Pipe, ASTM C-361, latest revision, except that strength may conform tothe requirements of ASTM C-76, with a minimum of “B” designation wallthickness, or the requirements of ASTM C-655, latest revision, for “D-Load”pipe,where permitted. Pipe shall be manufactured to the strength class shown onthe plans and/or indicated in the specifications.

B. Materials. Materials for the manufacture of reinforced concrete pipe shallconform to the requirements of the ASTM specifications listed above and shallinclude but not be limited to, the following:ASTM A-185 Welded Steel Wire Fabric for Concrete .ReinforcementASTM C-33 Specification for Concrete Aggregates.ASTM C-150 Specification for Portland Cement.

C. Joints. Joints may utilize steel joint rings, steel bells, and concrete spigots or beformed entirely of concrete. Joints shall contain at least one annular ring ofreinforcement in either the male of female end but in no case shall the jointreinforcement be less than that required in ASTM C-361. Joints shall be sealedusing a rubber gasket as the sole element to provide watertightness. All rubbergaskets shall fully comply with all requirements of ASTM C-443.

D. Quality Assurance. The interior surfaces of the pipe shall be a smooth, truecylindrical surface and shall be free of undulations or corrugations. No pipe shallexceed the permissible variations described in ASTM C-76, Section 12. Pipeshall be tested prior to delivery to thew job site in accordance with therequirements of ASTM C-361, Section 10, and ASTM C-497. Proof ofcompliance with the testing requirements shall be demonstrated to the purchaseprior to delivery of the pipe.

E. Marking. All pipe shall be clearly marked with the class, date of manufacture,and the manufacturer’s name or trademark. If elliptical reinforcement is used, theminor axes shall be designated on the outside of the pipe.

F. Fittings. All fittings shall be manufactured from pipe of the same type and classas the straight joints of pipe. Fittings shall be clearly marked with the fittingconfiguration.

Circular Pipe

Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR

870-935-5913 417-862-5088 918-542-1884 479-521-0504

Class III=Class IV=Class V=Contact our plant for Class I or Class II products

1350 lbs.2000 lbs.3000 lbs.

2000 lbs.3000 lbs.3750 lbs.

Intial D-load Ultimate load

NOTE:All circular pipe can be furnished in Class III, IV,V.

Reinforced Concrete Sewer Pipe complies with ASTM C-76with ASTM C-443 - Gasket

Joint Detail offered with single offset or confined O-ring.• Contact our plant for Special Design D-load products that are available.

Sanitary Pipe

Jonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR870-935-5913 417-862-5088 918-542-1884 479-521-0504

Scurlock IScurlock IScurlock IScurlock IScurlock Industriesndustriesndustriesndustriesndustries

Standard Precast Box Culvert SpecificationsI. Precast Concrete Box Culverts for ASTM C-850 or C-789 Standards

A. The precast concrete box sections for the culvert shall be in accordance with therequirements of ASTM C-1433. All boxes can be furnished in Interstate Loading,Earth Dead Loading, and Railroad Loading.

B. Fine and coarse aggregates for the concrete mixture shall comply with therequirements of ASTM Specifications.a) Cement shall comply with the requirements ASTM C-150.b) Steel shall comply with the requirements ASTM C-185, ASTM C-990.c) Joint sealing material, plastic type, shall comply with AASHTO M-198 orFederal Specification SS-S-210A.

C. Precast conical plugs shall be furnished for lifting holes.

D. Admixtures may be used with the approval of the engineer.

E. Curing shall be in accordance with ASTM standards. Box sections shallbe cured until the concrete developed the specified compressive strength.

F. End sections shall be precast to the same dimensions and shapes and withthe same reinforcement as shown for the culvert. Each precast endsection shall include approximately 2 feet of barrel floor, tapered 2 to 1as an integral unit. Precast headwalls and toe walls shall be furnishedas required.

G. The manufacturer may request approval of modified designs which differfrom the designs in ASTM C-1433. Such modified or special designsshall fully describe to the engineer any deviations from those standards.Computer designs shall be available for box culverts by the manufacturer.

H. The excavation and backfilling for the precast box sections and end sectionsshall be in accordance with the requirements of the manufacturer. The beddingshall be compacted to provide uniform support over the bottom of the box andend sections. No direct payment will be made for furnishing or placing granularmaterial.

I. The individual box section shall carefully be set to lines and grades shown on theplans with the female end upstream, and the male end extended the full lengthinto the adjacent section of box. When multicell boxes are used, a 1-1/2 inchminimum space shall be left between the adjacent precast sections. All jointsbetween individual box sections shall be sealed with an approved joint sealantmaterial.

J. Tapered precast plugs shall be thoroughly sealed with plastic joint material.Lifting devices shall have sufficient bearing on the inside of the box section toavoid damage resulting from a concentration stresses around the lift holes.

K. Preform tape type plastic compound shall be applied in accordance with themanufacturer’s recommendations.

L. Precast box culvert, complete in place, will be measured to the nearest foot alongthe geometrical center of the culvert.

M. The accepted quantities for the concrete box culvert complete in place will bepaid for at the unit price for the pay items included in the contract. Center-lineper lineal foot basis is recommended.

Precast Box Culvert Specifications (cont.)

Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR

870-935-5913 417-862-5088 918-542-1884 479-521-0504

Precast Box Culvert Installations

Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR

870-935-5913 417-862-5088 918-542-1884 479-521-0504

Advantages:

1. Savings of time in the project and on-site development.

2. Savings of initial costs.

3. Ease of installation.

4. Backfills immediately.

5. High strength concrete and quality control.

6. Shortens the number of days in a project.

7. Eliminates costly detours.

Standard Specifications for Manholes

Summary of Practice:All lift holes and any pipes entering the manhole are to be plugged. A vacuum will be

drawn and the vacuum drop over a specified time period is used to determine the acceptability ofthe manhole.

Procedure:A vacuum of 10 inches of mercury shall be drawn on the manhole, the valve on the

vacuum line of the test head is closed, and the vacuum pump shut off. The time shall bemeasured for the vacuum to drop from 10 inches of mercury to 9 inches.

The manhole shall pass if the time for the vacuum to drop to 9 inches of mercury meetsor exceeds the values indicated in the table below.

If the manhole fails thew initial test, necessary repairs shall be made by an approvedmethod. The manhole shall then be retested until a satisfactory test is obtained.

Minimum Test Times (in seconds) for Various Manhole Diameters

Jonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR870-935-5913 417-862-5088 918-542-1884 479-521-0504

Diameters (inches): 48 60 728 20 26 3310 25 33 4112 30 39 4414 35 46 5716 40 52 6718 45 59 7320 50 65 8122 55 72 8924 59 78 9726 64 85 10528 69 91 11330 74 98 121

Scurlock IScurlock IScurlock IScurlock IScurlock Industriesndustriesndustriesndustriesndustries

Precast Manholes

Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR

870-935-5913 417-862-5088 918-542-1884 479-521-0504

48” DiameterManhole Parts

Adjustment Rings: 2” thru 12”

Standard Risers: 12”, 16”, 24”, 32”, 48”

Bases: Variable

Precast Bottoms: 6” Std. ThicknessVariable on designs

Precast Bottom and Invert System

Cones: 24” Eccentric Cone30” Eccentric Cone36” Eccentric Cone38” Eccentric Cone

Precast Inlet Bases

Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR

870-935-5913 417-862-5088 918-542-1884 479-521-0504

Complies with ASTM C-478

Tee Base 36” x 7.5’ RCP Class 3 with 24 x 24 Tee Base Inlet

Flexible Connectors Arch OpeningPrecast Bottom and Invert No Bottom

Contact our plant for availability of various sizes of manholes.

Precast Sanitary Sewer Manholes

Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR

870-935-5913 417-862-5088 918-542-1884 479-521-0504

Precast EccentricCones

Joints - preform butyl rubber mastic

48” dia. Precast Manholesteel reinforcementshall be 0.12 sq. in.per vertical foot

Base(variable)

36”

48”

EAB

CS

Shallo w Manhole

Complies with ASTM C-478

F

OR

Flat in lieu of cone

Precast Storm / Sanitary Sewer Manholes

Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR

870-935-5913 417-862-5088 918-542-1884 479-521-0504

Polymer Modified Concrete Joint SealantPer ASTM-C-990/AASHTO M-198

34” O.D.

24” I.D. Ring and cover

Precast Eccentric Cones

Precast Reinforced Concrete Adjustment Ring(grade ring), 2” thru 12”

Minimum 4000 psi concrete

5” Wall

48” dia. Precast Manholesteel reinforcementshall be 0.12 sq. in.per vertical foot.

Manhole StepPer ASTM-C-478

6” Precast Flat Baseor predeveloped bottom& invert systemFlexible Connectors

Basevaries

Std.Riservaries

48”

STANDARD

Complies with ASTM C-478

varies

Precast Storm / Sanitary Sewer Manholes

Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR

870-935-5913 417-862-5088 918-542-1884 479-521-0504

Typical Manhole frame and cover(or casting - varies)

Precast Reinforced Concrete Adjustment Ring(grade ring), 2” thru 12”

Precast 48” dia.Reinforced Flat Top

Optional Exterior coating

48” dia. Precast Manholesteel reinforcementshall be 0.12 sq. in.per vertical foot.

Joints - performbutyl rubber mastic(or Forsheda gasketed)

Steps - optionalMSU, compositionor cast iron

48”

48”

6” Precast Flat Baseor predevelopment bottom& invert system

Optional Openings

Complies with ASTM C-478

varies

varies

varies

Precast Flat Top

Precast Sanitary Sewer Manholes

Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR

870-935-5913 417-862-5088 918-542-1884 479-521-0504

Typical Manhole frame and cover(or casting - varies)

Precast Reinforced Concrete Adjustment Ring(grade ring), 2” thru 12”

Optional Exterior coating

48” dia. Precast Manholesteel reinforcementshall be 0.12 sq. in.per vertical foot

Joints - performbutyl rubber mastic(or Forsheda gasketed)

Steps - optionalMSU, compositionor cast iron

Base SectionsReinforced ConcretePipe ASTM C-76with ASTM C-361confined O-RingSewer PipeSteel reinforcement

in accordance withASTM C-76

Wall Thickness

Precast Eccentric Cones(variable heights)

Complies with ASTM C-478

Tee Base Manhole With Cone

Precast Wetwells

Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR

870-935-5913 417-862-5088 918-542-1884 479-521-0504

VARIES

A dia

VARIES

Top ElevationC

B B

Floor ElevationD

For: Lift Station Housing, Precast Valve Vaults, Wetwells, Drywells,Holding Tanks, Air Release Manhole, Vacuum Manholes

Optional Features

- Coating - in or out

- Steps

- Sleeve openings or A Loks

- Flat Top Thickness

- Water Stop

- Extended Bases

- Casting

- Vent Sizes

- Joint Details

Standard Sizes

InsideDiameter

A

WallThickness

B

Flat TopThickness

C

PrecastFlat Bottom

D

OutsideDiameter

Weight PerVertical

Foot

48”60”72”84”96”120”

5-3/4”6-3/4”

7”8”9”10”

8”8”10”10”10”12”

6”8”8”

12”12”12”

59-1/2”73-1/2”

86”100”114”140”

1,011 lbs.1,477 lbs.1,811 lbs.2,407 lbs.3,090 lbs.4,254 lbs.

Complies with ASTM C-478Contact our plant for availability of various sizes of manholes.Contact our plant regarding square wetwells, wall thickness, etc.

Precast Wetwells

Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR

870-935-5913 417-862-5088 918-542-1884 479-521-0504

1

(above) 10’ x 10’ Precast Wetwell Installation (below) 96” Wetwells

Precast Lift Station Wetwells & Valve Vaults

Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR

870-935-5913 417-862-5088 918-542-1884 479-521-0504

PrecastFlat Tops

ForceMain

PrecastValve Vault

PrecastWetwell

inlet

outletPump Unit by others

Precast Wetwell

ForceMain

For: Submersible Pumps For: Top Mounted Pumps

Precast Wetwell Precast Valve Vault

sleeves

Access CoverVent

PrecastFlat Top

wallthickness

SubmersibleWastewater Pump

varies

Precast Bottom

dia.Precast Bottom

Access Cover

Specifications:

ASTM C-478with

4,000 PSI Concrete

Contact our plantfor special designsand changes in jointdesign.

Precast Curb Inlet

Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR

870-935-5913 417-862-5088 918-542-1884 479-521-0504

Flat Butt Joint

6”36”

48”

6” Arch 6”

36”

• Contact our plant for availability of various sizes of Precast Curb Inlets.

Outside: 3’x4’Inside” 2’x3’

varies

6” to 10 1/2”6”

Capacity of Precast Curb Opening Inlets

Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR

870-935-5913 417-862-5088 918-542-1884 479-521-0504

Curb Line Precast Curb Opening Inlet Curb Line

Gutter Line Area Gutter Line

4’

18”

4’

Curb opening throat6” high x 3’ wide

18”

8’ 4’

Curb opening throat6” high x 7’ wide’

CAPACITY OF INLETS IN C.F.S.

Depthat (X)

4’x4’ Unit(3’ opening)

4’x8’ Unit(7’ opening)

1”2”3”4”5”6”

1.31.82.63.44.25.2

3.04.46.28.010.112.6

Precast Junction Box

Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR

870-935-5913 417-862-5088 918-542-1884 479-521-0504

CastingDeeter #2018

Broomed and Edged

Ground Line

Reinforcement

6”

Varies

9”

- Contact our plant for availability of Precast Junction Boxes

Precast Utility Tunnels

Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR

870-935-5913 417-862-5088 918-542-1884 479-521-0504

Exterior Waterproofing

Straps(by contractors)

Rigid Conduit& Hangers(by contractor)

Gutter orwireway orhema enclosurepull box(by contractor)

Precast Utility Tunnels

Available in various designs and sizes.

Contact our plant for special modifications.

Precast Electrical Pullboxes

Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR

870-935-5913 417-862-5088 918-542-1884 479-521-0504

- Contact our plant for availability of various sizes of precast electrical modules.

Reinforcement meets all ASTM stan-dards.

Splice in conductors shall be allowedonly when conductor length exceeds 500 l.f.

Varies

E Bolt with cable tiefor conductor oreye bolt -if required Seal all connections watertight,

with scotchcast electrical splicingor an approved equal.

L 2”x2”x1/4”x4” LG.welded to steel plate(typical 4 places)

Conduit (typical)(All conduitending in pitsshall be sealedwatertight.)

Conduit bushing (typical)

3/8” Steel plate3’4” sq.

4”

4”

Varies

Varies4” 4”

Precast Electrical Manholes

Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR

870-935-5913 417-862-5088 918-542-1884 479-521-0504

6” sleeve

cable racks

27” x 13”Blockouts 4’3”

above floor

1-1/4”Sump Drain

3” sleeve48” above floorDeeter casting

9’4” overall depth

4’4” PVC Stub & Plug

30”

13” x 13” Blockout

Reinforcement meets ASTM standards

18”x18”x18” Sump

8”

8’9”

10”

7”

Precast Oil Interceptor

Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR

870-935-5913 417-862-5088 918-542-1884 501-521-0504

5” Outlet

6”

24”

6”

24” 24”

6”

6”

36”48”

6”

5” Inlet4” Sleeve

1” Preform Joint Material

Standard Deeter CastingGasket & bolt down required

4’ - 0” 3’ - 0”

2’ - 0”

2’ - 0” 2’ - 0” 2’ - 0”

6”

60”

75”

9”

dirt fill

Reinforcement meets ASTM standardsNOTE:All internal piping to bedone by the contractor.

• Contact our plant for availability of various sizes of Precast Oil Interceptors.

Optional coatingKopper’s Super Service Black

6”

Precast Oil Interceptor

Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR

870-935-5913 417-862-5088 918-542-1884 479-521-0504

Detail shown for a 72” tallbase with a 6” precast bottom

Outlet 6” sleeve

18” 36”

Inlet 6”sleeve

4” reinforcedPrecast baffles

standard Deeter casting

adjustment ring

flat top

10”

5’ - 6”

6’ - 10”

6”

• Contact our plant for availability of various of Precast Oil Interceptors.

72” reinforced walls meetASTM C-478 specifications

NOTE:All internal piping to bedone by the contractor

Precast Grease Trap

Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR

870-935-5913 417-862-5088 918-542-1884 479-521-0504

• Contact our plant for availability of various sizes of Precast Oil Interceptors.

Kopper’s Exterior Coating

8’

48” 36”

4” 4”4”

24” Opening

8” 40” 48”

4”

NOTE:All internal piping to bedone by the contractor.

Reinforcement meets all ASTM standards.8” sleeve opening for surfacecleanout

1” preform joint

6”

48”5’

6”

4”

Outlet

reinforced concrete baffle

8” sleeve opening

3/4” preform joint

38”36”

500 Gallon

Two Cell

Precast Grease Interceptor

Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR

870-935-5913 417-862-5088 918-542-1884 479-521-0504

108”

6” 60” 6” 30” 6”

inlet

Conc.Baffle

outlet72”

6”

6”

84”

Plan

(2) #1157 Deeter Castings

PreformJoint

Material

6”inlet

8” sleeves(typical) Conc.

Baffles

Section

38”

6”

6” 6”

48” 63”

8”2”

9”

Varies

24” Adjustment Rings4”

24”24”

Two Cell

1000 Gallon

Precast Chlorine Contact Tank

Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR

870-935-5913 417-862-5088 918-542-1884 479-521-0504

uncoated area

Exterior coated Kopper’sSuper Service Black

Keyed Joint

1’ - 9”

NOTE:All internal piping to be done

by the contractor.

Continuous keyed joint double sealwith 3/4” preform joint material.Edged

24” minimum

PVC pipe

dirt fill

6”

Reinforcement meets ASTM standardsContact our plant for availability of various sizes of Precast Chlorine Contact Tanks.

8” hole

5’ - 0”7’ - 4”

Pipe Tee

4’-Typicalkeyed

10”

Precast Vaults for Double Check Backflow Preventer

Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR

870-935-5913 417-862-5088 918-542-1884 479-521-0504

Water LineSize

Back Flow PreventerAverage Dimensions

B LengthA Length

C Length

D Length

E Height

F Wall

Thickness

G Top Slab

TotalWeight(lbs.)

4”

6”

8”

10”

52” long

66” long

72” long

82” long

28” tall

38” tall

48” tall

58” tall

6’0”

7’0”

8’0”

9’0”

3’0”

3’0”

4’0”

4’0”

4’0”

5’0”

6’0”

7’0”

6” or 8”

6” or 8”

6” or 8”

6” or 8”

HS30 loading 6” or 8”

6” or 8”

6” or 8”

6” or 8”

Reinforcements in Precast Vaults comply with ASTM A-82 and A-185.Contact our plant for modifications.

Precast floors with sleeve openings for water lines are optional.

7,350

11,350

15,350

17,350

Precast Concrete Vault

Technical Databackflow preventer assembly

(typical)

WaterLine

PrecastVault

Arch Openings

Traffic BearingFrame & CoverBroom & Edged Finish

Casting

Precast

F

A

CF F FD

EB

G

varie

s

Precast Retaining Walls

Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR

870-935-5913 417-862-5088 918-542-1884 501-521-0504

Mega

Standard

Mite

7”

20”19”

9.75”

12”19”

9.75”

5”

12” 13”

7”

• Contact our plant for more information.

Tornado Round

Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR

870-935-5913 417-862-5088 918-542-1884 479-521-0504

Outdoor CarpetingWalls & Floor

Bottled WaterTube

Wall MountedSeating

Wall MountedFire Extinguisher

ManwaySteps

Vent Tube

Wall MountedFirst Aid Kit

ExteriorWaterproof

Coated

VentTube

Alum.AccessDoor

FloorJoist

Joist

Wall

Floor Finish

steps

carpet

PrecastFlat Top

seats

Precast FloorPrecast Storm Shelter

Footing

FoundationWall

InteriorRoom

1’ -

6”m

inim

um

SectionNo Scale

Tornado Round

Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR

870-935-5913 417-862-5088 918-542-1884 479-521-0504

Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR

870-935-5913 417-862-5088 918-542-1884 479-521-0504

Precast Concrete Railroad Crossings

Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR

870-935-5913 417-862-5088 918-542-1884 479-521-0504

Precast Concrete Railroad Crossings

Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR

870-935-5913 417-862-5088 918-542-1884 501-521-0504

Precast Concrete Railroad Crossings