Scurlock Industries Industries Jonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR...
-
Upload
nguyenthien -
Category
Documents
-
view
221 -
download
5
Transcript of Scurlock Industries Industries Jonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR...
Our Company was established in 1953 inJonesboro, Arkansas, for the purpose of manu-facturing small diameter sewer pipe. Our history
of steady growth in both product lines andmanufacturing facilities has positioned us as aleader in the concrete products industry. Ourcompanies have the ability to produce almostany precast concrete product while supportingthat function with an engineering and quality
control staff.
Miami, OK
Fayetteville, AR
Springfield, MO
Jonesboro, AR
Introduction
Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesScurlock IScurlock IScurlock IScurlock IScurlock Industriesndustriesndustriesndustriesndustries
Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR
870-935-5913 417-862-5088 918-542-1884 479-521-0504
I. Reinforced Concrete Pipe.
A. Scope of Work. The work shall consist of furnishing all labor, materials, andequipment for the complete installation of storm sewer pipe, in conformance withthe lines and grades shown on the plans or as established by the Engineer.Items of work or materials not specifically mentioned but necessary for thecompletion of storm sewer line construction shall be considered as incidentalto the items in the contract.
B. Materials.a) Pipe. Pipe shall be of the type, size, and class shown on the plans.
b) Reinforced Concrete Culvert Pipe. Reinforced concrete culvert pipeshall conform to the requirements of the Specifications for ReinforcedConcrete Culvert Pipe, ASTM C-76. Installations shall be made withcircular pipe conforming to the requirements for class III, class IV, orclass V, B-Wall, or C-Wall, of the ASTM C-76 specification.
c) All precast flared end sections shall conform to ASTM C-76. Toe wallsrequired shall conform to AASHTO M-170.1) All precast Bends, Wyes, and Tees shall comply with ASTM C-76,
AASHTO M-170 or Federal Specification SS-P-375.
d) Fine and coarse aggregates for the concrete mixture shall comply with therequirements of ASTM specifications.1) Cement shall comply with the requirements of ASTM C-150.2) Steel shall comply with the requirements ASTM C-185.3) Joint sealing material, plastic type, shall comply with ASTM
C-990, AASHTO M-198, or Federal Specification SS-S-210A.
e) D-load design pipe shall conform to ASTM C-655.
f) Preform tape-type plastic compound shall be applied in accordance with themanufacturer’s recommendations.
Standard Storm Sewer Specifications for Culverts
Circular Pipe ASTM C-76
Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR
870-935-5913 417-862-5088 918-542-1884 479-521-0504
“A”InsideDia.
“B”Outside
Dia.
“C”Wall
Thickness
“D”Joint
LengthWaterway
AreaWeight
Per Foot
BulkCompound
Lbs. Per Joint
PreformedJt. Material
in Ft.
12”15”18”21”24”30”30”36”42”48”54”60”66”72”78”84”96”
120”
16”19 - 1/2”
23”26 - 1/2”
30”38 - 1/2”37 - 1/4”45 - 1/2”52 - 1/2”59 - 1/2”66 - 1/2”73 - 1/2”80 - 1/2”
86”93”
100”114”140”
4’ & 6’4’ & 6’
4’, 6’, 7-1/2’4’ & 6’
4’, 6’, 7-1/2’4’ & 7-1/2’
4’ & 6’4’ & 7-1/2’4’ & 7-1/2’4’ & 7-1/2’
7-1/2’4’ & 7-1/2’
7-1/2’4’, 7-1/2’ & 8’
8’7-1/2’
4’4’
B 2”B 2-1/4”B 2-1/2”B 2-3/4”
B 3”C 4-1/4”B 3-3/4”C 4-3/4”C 5-1/4”C 5-3/4”C 6-1/4”C 6-3/4”C 7-1/4”
B 7”B 7-1/2”
B 8”B 9”A 10”
.79 sf.1.23 sf.1.77 sf.2.41 sf.3.14 sf.4.91 sf.4.91 sf.7.07 sf.9.62 sf.
12.57 sf.15.90 sf.19.64 sf.23.76 sf.28.28 sf.33.18 sf.38.47 sf.50.27 sf.78.54 sf.
95 lbs.127 lbs.168 lbs.214 lbs.264 lbs.476 lbs.400 lbs.654 lbs.811 lbs.
1011 lbs.1230 lbs.1477 lbs.1735 lbs.1811 lbs.2100 lbs.2410 lbs.3090 lbs.4263 lbs.
1.622.774.006.107.80
10.0010.0018.7
28.5029.0045.0059.0076.0093.0095.00
137.00195.00255.00
3.204.004.905.506.258.008.009.50
11.0012.6014.2015.7517.2518.9020.5022.0025.2031.50
Class III =Class IV =Class V =
1350 lbs.2000 lbs.3000 lbs.
2000 lbs.3000 lbs.3750 lbs.
NOTE: All circular pipe can be furnished in ClassIII, IV, and V, or special designs. Contact our plantfor Class I or Class II products
ASTM C - 76 Pipe Data
InitialD-Load
Ulitmate Load
Circular Pipe
Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR
870-935-5913 417-862-5088 918-542-1884 479-521-0504
Reinforced Concrete Culvert Pipe complies withASTM C-76
I.D.
End View Side View
tongue
grooveMortar Joint
Pipe Joint Area
c
c
a b
d
NOTE:All Circular pipe can be furnished in Class III, IV, V or Special design D-load.
Class III =Class IV =Class V =
1350 lbs.2000 lbs.3000 lbs.
2000 lbs.3000 lbs.3750 lbs.
Initial D-Load
Ultimate Load
Contact our plant for Class I or Class II products
C-76 Mortar Joint BendCulvert Pipe
Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR
870-935-5913 417-862-5088 918-542-1884 479-521-0504
Typical fitting made from astandard piece of pipe. Pipemanufactured to meet ASTM C-76specifications, including reinforce-ment for Class III, IV or V.
NOTE: Reinforcement in both pieces to be weldedtogether at time of construction.
C & D Approximately 1/2 length of pipe less loss due to cut.
12” thru 24” 4 ft. pipe joints30” thru 72” 7.5 ft. pipe joints
A RCP Inside DiameterB RCP Outside Diameter
A B
C
D
Variable0 degrees to90 degrees
• Contact our plant for all confirmations on RCP Bend sizes.
Flared End Section
Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR
870-935-5913 417-862-5088 918-542-1884 479-521-0504
Dia.
12”15”18”21”24”27”30”36”42”48”54”60”66”72”84”
Wall
2”2-1/4”2-1/2”2-3/4”
3”3-1/4”3-1/2”
4”4-1/2”
5”5-1/2”
6”6-1/2”
7”
Weight
530 lbs.750 lbs.990 lbs.1284 lbs.1520 lbs.1855 lbs.2190 lbs.4100 lbs.5380 lbs.6550 lbs.8040 lbs.8750 lbs.9400 lbs.
12,520 lbs.
A
4”6”9”9”
9-1/2”10-1/2”
1’0”1’3”1’9”2’0”2’3”2’6”2’0”2’0”
B Min.
4’0”3’10”3’10”3’2”2’6”2’1”1’7”2’10”2’11”2’2”2’11”3’3”1’9”1’9”
C Min.
6’6’6’6’6’6’6’8’8’8’8’8’8’
8’3”
D
2’0”2’6”3’0”3’6”4’0”4’6”5’0”6’0”6’6”7’0”7’6”8’0”8’6”9’0”
E
18”18”18”18”24”24”24”24”24”24”36”36”36”42”
Layer of Grout betweenEnd Section and Toe Wall
WallPlus 6”
D
Diameter
Toe Wall Constructedat Outlet End Only
WallB
C
8”
Wall
Dimensions
Contact our plant for details
NOTE:All flared ends are manufactured to ASTM specifications and state highway stan-dards
A
Bell or Spigot as required
E
Precast Flared Ends
Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR
870-935-5913 417-862-5088 918-542-1884 479-521-0504
12151821242730364248546066
0.070.070.070.070.070.130.140.120.150.180.220.250.31
0.090.120.140.160.190.23
0.070.070.070.110.120.130.170.200.240.280.34
0.0480.0540.0600.0660.0720.0780.0840.0960.1080.1200.1320.1440.156
0.0480.0540.0600.0660.0720.0780.0840.0960.1080.1200.1320.1440.156
AdjoiningPipe Dia.Inches
InnerCage
Sq. In./Lin. Ft.
OuterCage
Sq. In./Lin. Ft.
Circular
Barrel SectionReinforcement
Elliptical
Flare SectionReinforcement(one layer only
in center of wall)Area of
LongitudinalSq. In./Lin. Ft.
Area ofTransverse
Sq. In./Lin. Ft.
STATE-APPROVED Flared Ends available 12” thru 84”
Reinforcement
Typical Pipe Installations
Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR
870-935-5913 417-862-5088 918-542-1884 479-521-0504
ASTM C-76Class 560” RCP
8
Horizontal Elliptical Pipe
Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR
870-935-5913 417-862-5088 918-542-1884 479-521-0504
EquivalentRoundSize
Rise & SpanInside
Diameter
Classification(UltimateStrength)
WallThickness
Weight(PerFt.)
Area(Sq.Ft.)
Length(Pipe
Section)
Outside Diameter(O.D.)
Vertical Horizontal
18”
24”
30”
36”
42”
48”
54”
60”
14” x 23”
19” x 30”
24” x 38”
29” x 45”
34” x 53”
38” x 60”
43” x 68”
48” x 76”
C-2, C-3, C-4
C-2, C-3, C-4
C-2, C-3, C-4
C-2, C-3, C-4
C-2, C-3, C-4
C-2, C-3, - -
C-2, C-3, - -
C-2, C-3, - -
2-3/4”
3-1/4”
3-3/4”
4-1/2”
5”
5-1/2”
6”
6-1/24”
200 lbs.
300 lbs.
430 lbs.
625 lbs.
815 lbs.
1000 lbs.
1235 lbs.
1475 lbs.
1.8
3.3
5.1
7.4
10.2
12.9
16.6
20.5
7.5’
7.5’
7.5’
7.5’
7.5’
7.5’
6’
5’
19-1/2”
25-1/2”
31-1/2”
38”
44”
49”
55”
61”
28-1/2”
36-1/2”
45-1/2”
54”
63”
71”
80”
89”
18” HE RCP through 36” HE RCP is available 7-1/2’ joints.
Span
Rise
End View
Length
Wall
Side View
Reinf.
tongue
grooveMortar Joint
Pipe Joint Area
Reinforced Concrete Culvert Pipe complies with ASTM C - 507
Contact our plant for Special Design D-Load HE products that are available
Elliptical RCP
Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR
870-935-5913 417-862-5088 918-542-1884 479-521-0504
Rise& Span
RoundEquiv.
JointLength
Weight(lbs.)
14” x 23”
19” x 30”
24” x 38”
29” x 45”
34” x 53”
38” x 60”
43” x 68”
48” x 76”
18”
24”
30”
36”
42”
48”
54”
60”
7 1/2’
7 1/2’
7 1/2’
7 1/2’
7 1/2’
7 1/2’
6’
5’
1500 lbs.
1680 lbs.
2280 lbs.
3380 lbs.
4480 lbs.
5580 lbs.
6880 lbs.
6980 lbs.
24 “ through 36” End Section available in 7 - 1/2’ lengths.
Span
Rise
midline of HE RCP upstream shown
Available in upstream and downstream tapered end sections in the following sizes:
Tapered End SectionsASTM C-507
Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR
870-935-5913 417-862-5088 918-542-1884 479-521-0504
Standard SpecificationsSanitary Sewer Pipe
Reinforced Concrete Pipe:A. General. Reinforced concrete pipe shall be precast and shall conform to the
requirements of The Standard Specifications for Reinforced Concrete Low-HeadPressure Pipe, ASTM C-361, latest revision, except that strength may conform tothe requirements of ASTM C-76, with a minimum of “B” designation wallthickness, or the requirements of ASTM C-655, latest revision, for “D-Load”pipe,where permitted. Pipe shall be manufactured to the strength class shown onthe plans and/or indicated in the specifications.
B. Materials. Materials for the manufacture of reinforced concrete pipe shallconform to the requirements of the ASTM specifications listed above and shallinclude but not be limited to, the following:ASTM A-185 Welded Steel Wire Fabric for Concrete .ReinforcementASTM C-33 Specification for Concrete Aggregates.ASTM C-150 Specification for Portland Cement.
C. Joints. Joints may utilize steel joint rings, steel bells, and concrete spigots or beformed entirely of concrete. Joints shall contain at least one annular ring ofreinforcement in either the male of female end but in no case shall the jointreinforcement be less than that required in ASTM C-361. Joints shall be sealedusing a rubber gasket as the sole element to provide watertightness. All rubbergaskets shall fully comply with all requirements of ASTM C-443.
D. Quality Assurance. The interior surfaces of the pipe shall be a smooth, truecylindrical surface and shall be free of undulations or corrugations. No pipe shallexceed the permissible variations described in ASTM C-76, Section 12. Pipeshall be tested prior to delivery to thew job site in accordance with therequirements of ASTM C-361, Section 10, and ASTM C-497. Proof ofcompliance with the testing requirements shall be demonstrated to the purchaseprior to delivery of the pipe.
E. Marking. All pipe shall be clearly marked with the class, date of manufacture,and the manufacturer’s name or trademark. If elliptical reinforcement is used, theminor axes shall be designated on the outside of the pipe.
F. Fittings. All fittings shall be manufactured from pipe of the same type and classas the straight joints of pipe. Fittings shall be clearly marked with the fittingconfiguration.
Circular Pipe
Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR
870-935-5913 417-862-5088 918-542-1884 479-521-0504
Class III=Class IV=Class V=Contact our plant for Class I or Class II products
1350 lbs.2000 lbs.3000 lbs.
2000 lbs.3000 lbs.3750 lbs.
Intial D-load Ultimate load
NOTE:All circular pipe can be furnished in Class III, IV,V.
Reinforced Concrete Sewer Pipe complies with ASTM C-76with ASTM C-443 - Gasket
Joint Detail offered with single offset or confined O-ring.• Contact our plant for Special Design D-load products that are available.
Sanitary Pipe
Jonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR870-935-5913 417-862-5088 918-542-1884 479-521-0504
Scurlock IScurlock IScurlock IScurlock IScurlock Industriesndustriesndustriesndustriesndustries
Standard Precast Box Culvert SpecificationsI. Precast Concrete Box Culverts for ASTM C-850 or C-789 Standards
A. The precast concrete box sections for the culvert shall be in accordance with therequirements of ASTM C-1433. All boxes can be furnished in Interstate Loading,Earth Dead Loading, and Railroad Loading.
B. Fine and coarse aggregates for the concrete mixture shall comply with therequirements of ASTM Specifications.a) Cement shall comply with the requirements ASTM C-150.b) Steel shall comply with the requirements ASTM C-185, ASTM C-990.c) Joint sealing material, plastic type, shall comply with AASHTO M-198 orFederal Specification SS-S-210A.
C. Precast conical plugs shall be furnished for lifting holes.
D. Admixtures may be used with the approval of the engineer.
E. Curing shall be in accordance with ASTM standards. Box sections shallbe cured until the concrete developed the specified compressive strength.
F. End sections shall be precast to the same dimensions and shapes and withthe same reinforcement as shown for the culvert. Each precast endsection shall include approximately 2 feet of barrel floor, tapered 2 to 1as an integral unit. Precast headwalls and toe walls shall be furnishedas required.
G. The manufacturer may request approval of modified designs which differfrom the designs in ASTM C-1433. Such modified or special designsshall fully describe to the engineer any deviations from those standards.Computer designs shall be available for box culverts by the manufacturer.
H. The excavation and backfilling for the precast box sections and end sectionsshall be in accordance with the requirements of the manufacturer. The beddingshall be compacted to provide uniform support over the bottom of the box andend sections. No direct payment will be made for furnishing or placing granularmaterial.
I. The individual box section shall carefully be set to lines and grades shown on theplans with the female end upstream, and the male end extended the full lengthinto the adjacent section of box. When multicell boxes are used, a 1-1/2 inchminimum space shall be left between the adjacent precast sections. All jointsbetween individual box sections shall be sealed with an approved joint sealantmaterial.
J. Tapered precast plugs shall be thoroughly sealed with plastic joint material.Lifting devices shall have sufficient bearing on the inside of the box section toavoid damage resulting from a concentration stresses around the lift holes.
K. Preform tape type plastic compound shall be applied in accordance with themanufacturer’s recommendations.
L. Precast box culvert, complete in place, will be measured to the nearest foot alongthe geometrical center of the culvert.
M. The accepted quantities for the concrete box culvert complete in place will bepaid for at the unit price for the pay items included in the contract. Center-lineper lineal foot basis is recommended.
Precast Box Culvert Specifications (cont.)
Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR
870-935-5913 417-862-5088 918-542-1884 479-521-0504
Precast Box Culvert Installations
Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR
870-935-5913 417-862-5088 918-542-1884 479-521-0504
Advantages:
1. Savings of time in the project and on-site development.
2. Savings of initial costs.
3. Ease of installation.
4. Backfills immediately.
5. High strength concrete and quality control.
6. Shortens the number of days in a project.
7. Eliminates costly detours.
Standard Specifications for Manholes
Summary of Practice:All lift holes and any pipes entering the manhole are to be plugged. A vacuum will be
drawn and the vacuum drop over a specified time period is used to determine the acceptability ofthe manhole.
Procedure:A vacuum of 10 inches of mercury shall be drawn on the manhole, the valve on the
vacuum line of the test head is closed, and the vacuum pump shut off. The time shall bemeasured for the vacuum to drop from 10 inches of mercury to 9 inches.
The manhole shall pass if the time for the vacuum to drop to 9 inches of mercury meetsor exceeds the values indicated in the table below.
If the manhole fails thew initial test, necessary repairs shall be made by an approvedmethod. The manhole shall then be retested until a satisfactory test is obtained.
Minimum Test Times (in seconds) for Various Manhole Diameters
Jonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR870-935-5913 417-862-5088 918-542-1884 479-521-0504
Diameters (inches): 48 60 728 20 26 3310 25 33 4112 30 39 4414 35 46 5716 40 52 6718 45 59 7320 50 65 8122 55 72 8924 59 78 9726 64 85 10528 69 91 11330 74 98 121
Scurlock IScurlock IScurlock IScurlock IScurlock Industriesndustriesndustriesndustriesndustries
Precast Manholes
Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR
870-935-5913 417-862-5088 918-542-1884 479-521-0504
48” DiameterManhole Parts
Adjustment Rings: 2” thru 12”
Standard Risers: 12”, 16”, 24”, 32”, 48”
Bases: Variable
Precast Bottoms: 6” Std. ThicknessVariable on designs
Precast Bottom and Invert System
Cones: 24” Eccentric Cone30” Eccentric Cone36” Eccentric Cone38” Eccentric Cone
Precast Inlet Bases
Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR
870-935-5913 417-862-5088 918-542-1884 479-521-0504
Complies with ASTM C-478
Tee Base 36” x 7.5’ RCP Class 3 with 24 x 24 Tee Base Inlet
Flexible Connectors Arch OpeningPrecast Bottom and Invert No Bottom
Contact our plant for availability of various sizes of manholes.
Precast Sanitary Sewer Manholes
Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR
870-935-5913 417-862-5088 918-542-1884 479-521-0504
Precast EccentricCones
Joints - preform butyl rubber mastic
48” dia. Precast Manholesteel reinforcementshall be 0.12 sq. in.per vertical foot
Base(variable)
36”
48”
EAB
CS
Shallo w Manhole
Complies with ASTM C-478
F
OR
Flat in lieu of cone
Precast Storm / Sanitary Sewer Manholes
Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR
870-935-5913 417-862-5088 918-542-1884 479-521-0504
Polymer Modified Concrete Joint SealantPer ASTM-C-990/AASHTO M-198
34” O.D.
24” I.D. Ring and cover
Precast Eccentric Cones
Precast Reinforced Concrete Adjustment Ring(grade ring), 2” thru 12”
Minimum 4000 psi concrete
5” Wall
48” dia. Precast Manholesteel reinforcementshall be 0.12 sq. in.per vertical foot.
Manhole StepPer ASTM-C-478
6” Precast Flat Baseor predeveloped bottom& invert systemFlexible Connectors
Basevaries
Std.Riservaries
48”
STANDARD
Complies with ASTM C-478
varies
Precast Storm / Sanitary Sewer Manholes
Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR
870-935-5913 417-862-5088 918-542-1884 479-521-0504
Typical Manhole frame and cover(or casting - varies)
Precast Reinforced Concrete Adjustment Ring(grade ring), 2” thru 12”
Precast 48” dia.Reinforced Flat Top
Optional Exterior coating
48” dia. Precast Manholesteel reinforcementshall be 0.12 sq. in.per vertical foot.
Joints - performbutyl rubber mastic(or Forsheda gasketed)
Steps - optionalMSU, compositionor cast iron
48”
48”
6” Precast Flat Baseor predevelopment bottom& invert system
Optional Openings
Complies with ASTM C-478
varies
varies
varies
Precast Flat Top
Precast Sanitary Sewer Manholes
Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR
870-935-5913 417-862-5088 918-542-1884 479-521-0504
Typical Manhole frame and cover(or casting - varies)
Precast Reinforced Concrete Adjustment Ring(grade ring), 2” thru 12”
Optional Exterior coating
48” dia. Precast Manholesteel reinforcementshall be 0.12 sq. in.per vertical foot
Joints - performbutyl rubber mastic(or Forsheda gasketed)
Steps - optionalMSU, compositionor cast iron
Base SectionsReinforced ConcretePipe ASTM C-76with ASTM C-361confined O-RingSewer PipeSteel reinforcement
in accordance withASTM C-76
Wall Thickness
Precast Eccentric Cones(variable heights)
Complies with ASTM C-478
Tee Base Manhole With Cone
Precast Wetwells
Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR
870-935-5913 417-862-5088 918-542-1884 479-521-0504
VARIES
A dia
VARIES
Top ElevationC
B B
Floor ElevationD
For: Lift Station Housing, Precast Valve Vaults, Wetwells, Drywells,Holding Tanks, Air Release Manhole, Vacuum Manholes
Optional Features
- Coating - in or out
- Steps
- Sleeve openings or A Loks
- Flat Top Thickness
- Water Stop
- Extended Bases
- Casting
- Vent Sizes
- Joint Details
Standard Sizes
InsideDiameter
A
WallThickness
B
Flat TopThickness
C
PrecastFlat Bottom
D
OutsideDiameter
Weight PerVertical
Foot
48”60”72”84”96”120”
5-3/4”6-3/4”
7”8”9”10”
8”8”10”10”10”12”
6”8”8”
12”12”12”
59-1/2”73-1/2”
86”100”114”140”
1,011 lbs.1,477 lbs.1,811 lbs.2,407 lbs.3,090 lbs.4,254 lbs.
Complies with ASTM C-478Contact our plant for availability of various sizes of manholes.Contact our plant regarding square wetwells, wall thickness, etc.
Precast Wetwells
Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR
870-935-5913 417-862-5088 918-542-1884 479-521-0504
1
(above) 10’ x 10’ Precast Wetwell Installation (below) 96” Wetwells
Precast Lift Station Wetwells & Valve Vaults
Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR
870-935-5913 417-862-5088 918-542-1884 479-521-0504
PrecastFlat Tops
ForceMain
PrecastValve Vault
PrecastWetwell
inlet
outletPump Unit by others
Precast Wetwell
ForceMain
For: Submersible Pumps For: Top Mounted Pumps
Precast Wetwell Precast Valve Vault
sleeves
Access CoverVent
PrecastFlat Top
wallthickness
SubmersibleWastewater Pump
varies
Precast Bottom
dia.Precast Bottom
Access Cover
Specifications:
ASTM C-478with
4,000 PSI Concrete
Contact our plantfor special designsand changes in jointdesign.
Precast Curb Inlet
Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR
870-935-5913 417-862-5088 918-542-1884 479-521-0504
Flat Butt Joint
6”36”
48”
6” Arch 6”
36”
• Contact our plant for availability of various sizes of Precast Curb Inlets.
Outside: 3’x4’Inside” 2’x3’
varies
6” to 10 1/2”6”
Capacity of Precast Curb Opening Inlets
Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR
870-935-5913 417-862-5088 918-542-1884 479-521-0504
Curb Line Precast Curb Opening Inlet Curb Line
Gutter Line Area Gutter Line
4’
18”
4’
Curb opening throat6” high x 3’ wide
18”
8’ 4’
Curb opening throat6” high x 7’ wide’
CAPACITY OF INLETS IN C.F.S.
Depthat (X)
4’x4’ Unit(3’ opening)
4’x8’ Unit(7’ opening)
1”2”3”4”5”6”
1.31.82.63.44.25.2
3.04.46.28.010.112.6
Precast Junction Box
Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR
870-935-5913 417-862-5088 918-542-1884 479-521-0504
CastingDeeter #2018
Broomed and Edged
Ground Line
Reinforcement
6”
Varies
9”
- Contact our plant for availability of Precast Junction Boxes
Precast Utility Tunnels
Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR
870-935-5913 417-862-5088 918-542-1884 479-521-0504
Exterior Waterproofing
Straps(by contractors)
Rigid Conduit& Hangers(by contractor)
Gutter orwireway orhema enclosurepull box(by contractor)
Precast Utility Tunnels
Available in various designs and sizes.
Contact our plant for special modifications.
Precast Electrical Pullboxes
Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR
870-935-5913 417-862-5088 918-542-1884 479-521-0504
- Contact our plant for availability of various sizes of precast electrical modules.
Reinforcement meets all ASTM stan-dards.
Splice in conductors shall be allowedonly when conductor length exceeds 500 l.f.
Varies
E Bolt with cable tiefor conductor oreye bolt -if required Seal all connections watertight,
with scotchcast electrical splicingor an approved equal.
L 2”x2”x1/4”x4” LG.welded to steel plate(typical 4 places)
Conduit (typical)(All conduitending in pitsshall be sealedwatertight.)
Conduit bushing (typical)
3/8” Steel plate3’4” sq.
4”
4”
Varies
Varies4” 4”
Precast Electrical Manholes
Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR
870-935-5913 417-862-5088 918-542-1884 479-521-0504
6” sleeve
cable racks
27” x 13”Blockouts 4’3”
above floor
1-1/4”Sump Drain
3” sleeve48” above floorDeeter casting
9’4” overall depth
4’4” PVC Stub & Plug
30”
13” x 13” Blockout
Reinforcement meets ASTM standards
18”x18”x18” Sump
8”
8’9”
10”
7”
Precast Oil Interceptor
Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR
870-935-5913 417-862-5088 918-542-1884 501-521-0504
5” Outlet
6”
24”
6”
24” 24”
6”
6”
36”48”
6”
5” Inlet4” Sleeve
1” Preform Joint Material
Standard Deeter CastingGasket & bolt down required
4’ - 0” 3’ - 0”
2’ - 0”
2’ - 0” 2’ - 0” 2’ - 0”
6”
60”
75”
9”
dirt fill
Reinforcement meets ASTM standardsNOTE:All internal piping to bedone by the contractor.
• Contact our plant for availability of various sizes of Precast Oil Interceptors.
Optional coatingKopper’s Super Service Black
6”
Precast Oil Interceptor
Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR
870-935-5913 417-862-5088 918-542-1884 479-521-0504
Detail shown for a 72” tallbase with a 6” precast bottom
Outlet 6” sleeve
18” 36”
Inlet 6”sleeve
4” reinforcedPrecast baffles
standard Deeter casting
adjustment ring
flat top
10”
5’ - 6”
6’ - 10”
6”
• Contact our plant for availability of various of Precast Oil Interceptors.
72” reinforced walls meetASTM C-478 specifications
NOTE:All internal piping to bedone by the contractor
Precast Grease Trap
Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR
870-935-5913 417-862-5088 918-542-1884 479-521-0504
• Contact our plant for availability of various sizes of Precast Oil Interceptors.
Kopper’s Exterior Coating
8’
48” 36”
4” 4”4”
24” Opening
8” 40” 48”
4”
NOTE:All internal piping to bedone by the contractor.
Reinforcement meets all ASTM standards.8” sleeve opening for surfacecleanout
1” preform joint
6”
48”5’
6”
4”
Outlet
reinforced concrete baffle
8” sleeve opening
3/4” preform joint
38”36”
500 Gallon
Two Cell
Precast Grease Interceptor
Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR
870-935-5913 417-862-5088 918-542-1884 479-521-0504
108”
6” 60” 6” 30” 6”
inlet
Conc.Baffle
outlet72”
6”
6”
84”
Plan
(2) #1157 Deeter Castings
PreformJoint
Material
6”inlet
8” sleeves(typical) Conc.
Baffles
Section
38”
6”
6” 6”
48” 63”
8”2”
9”
Varies
24” Adjustment Rings4”
24”24”
Two Cell
1000 Gallon
Precast Chlorine Contact Tank
Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR
870-935-5913 417-862-5088 918-542-1884 479-521-0504
uncoated area
Exterior coated Kopper’sSuper Service Black
Keyed Joint
1’ - 9”
NOTE:All internal piping to be done
by the contractor.
Continuous keyed joint double sealwith 3/4” preform joint material.Edged
24” minimum
PVC pipe
dirt fill
6”
Reinforcement meets ASTM standardsContact our plant for availability of various sizes of Precast Chlorine Contact Tanks.
8” hole
5’ - 0”7’ - 4”
Pipe Tee
4’-Typicalkeyed
10”
Precast Vaults for Double Check Backflow Preventer
Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR
870-935-5913 417-862-5088 918-542-1884 479-521-0504
Water LineSize
Back Flow PreventerAverage Dimensions
B LengthA Length
C Length
D Length
E Height
F Wall
Thickness
G Top Slab
TotalWeight(lbs.)
4”
6”
8”
10”
52” long
66” long
72” long
82” long
28” tall
38” tall
48” tall
58” tall
6’0”
7’0”
8’0”
9’0”
3’0”
3’0”
4’0”
4’0”
4’0”
5’0”
6’0”
7’0”
6” or 8”
6” or 8”
6” or 8”
6” or 8”
HS30 loading 6” or 8”
6” or 8”
6” or 8”
6” or 8”
Reinforcements in Precast Vaults comply with ASTM A-82 and A-185.Contact our plant for modifications.
Precast floors with sleeve openings for water lines are optional.
7,350
11,350
15,350
17,350
Precast Concrete Vault
Technical Databackflow preventer assembly
(typical)
WaterLine
PrecastVault
Arch Openings
Traffic BearingFrame & CoverBroom & Edged Finish
Casting
Precast
F
A
CF F FD
EB
G
varie
s
Precast Retaining Walls
Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR
870-935-5913 417-862-5088 918-542-1884 501-521-0504
Mega
Standard
Mite
7”
20”19”
9.75”
12”19”
9.75”
5”
12” 13”
7”
• Contact our plant for more information.
Tornado Round
Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR
870-935-5913 417-862-5088 918-542-1884 479-521-0504
Outdoor CarpetingWalls & Floor
Bottled WaterTube
Wall MountedSeating
Wall MountedFire Extinguisher
ManwaySteps
Vent Tube
Wall MountedFirst Aid Kit
ExteriorWaterproof
Coated
VentTube
Alum.AccessDoor
FloorJoist
Joist
Wall
Floor Finish
steps
carpet
PrecastFlat Top
seats
Precast FloorPrecast Storm Shelter
Footing
FoundationWall
InteriorRoom
1’ -
6”m
inim
um
SectionNo Scale
Tornado Round
Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR
870-935-5913 417-862-5088 918-542-1884 479-521-0504
Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR
870-935-5913 417-862-5088 918-542-1884 479-521-0504
Precast Concrete Railroad Crossings
Scurlock IScurlock IScurlock IScurlock IScurlock IndustriesndustriesndustriesndustriesndustriesJonesboro, AR - Springfield, MO - Miami, OK - Fayetteville, AR
870-935-5913 417-862-5088 918-542-1884 479-521-0504
Precast Concrete Railroad Crossings