Data CenteSchneider Electric Solutions
Deliveing the Gaya Advantage
-
7/29/2019 Schneider Datacenter
2/16
2
Schneider Electric Solutions | Deliveing the Gaya Advantage
Data Center Solutions
Power, Cooling & Protection
Making The Connections...
...between IT and acilities:
Schneider Electric views the data center as an
interconnected environment. We call it the data
center physical inrastructure. The data center
physical inrastructure bridges all key data center
subsystems and is the clear, cost eective path to
the highest availability and maximum efciency.
Power, cooling, security, physical structure and
management Schneider Electric delivers expert
solutions and services across these complex
domains.
...between efciency and availability:We understand the need to reduce operating
costs AND maximize energy efciency
but never at the expense o availability. For
example, to enable worry-ree virtualization,
Schneider Electrics cooling strategies combine
acility-based perimeter cooling with hot
aisle containment and row-based cooling, all
monitored and managed via an integrated
sotware platorm. This interconnected solution
achieves higher availability and better energy
savings, while careully controlling operatingexpenses.
...between design and deployment:
Only Schneider Electric eatures a highly
experienced, cross-unctional team o
experts the Data Center Solutions Team
to manage your vendor relationships and
provide customized but highly repeatable data
center designs. This careul coordination rom
conception to commissioning reduces delays
and mistakes, improving speed to market.
Schneider Electricoers a ull portolioo leading-edgesolutions or criticalpower applicationswith productssuch as SquareD Masterpactcircuit breakers,PowerLogic circuitmonitors andmeters, Power-
Zone 4 switchgear,APCs InraStruxure,Pelco securityand buildingmanagementsystems.
Whether Tier 1 or Tier IV, Schneider Electric designs and delivers an ultrareliable, tiered system that meets the needs o your data center.
Schneider Electrics data center project management team managescommunication and coordination among all parties includinggenerator manuacturers, UPS manuacturers, paralleling switchgearmanuacturers, electrical contractors and consulting engineers.
-
7/29/2019 Schneider Datacenter
3/16
3
1-800-GrAYbAr | gaya.com
Make the Most of Your Energy!
> PowerThe Schneider Electric power domain connectsit all from generators, transformers andswitchgear to UPSs, breakers and PDUs
to deliver cross-vendor interoperability.
> Cooling
Our integrated solutions combine chillers,
perimeter cooling, hot aisle containmentand row-based options to maximizeefciency and guarantee availability.
> Rack Systems
Interconnected, any IT vendor-compatiblerack enclosures, accessories and air
containment solutions easily support allyour HD processing needs.
> ManagementFor the ultimate connection, Schneider Electricsexclusive integrated software architectureremoves management silos to create greater
energy awareness and efciency as well ashigher availability across the entire data centerphysical infrastructure.
> Services
Any equipment. Any brand. Any time. Anyplace. Schneider Electric offers increased safety,
lower life cycle cost and maximum electricaldistribution system reliability for your peaceof mind.
> Physical Security
Schneider Electrics single-seat view includes
access control and surveillance across one ormultiple facilities.
Get Connected to the Six Key Domains o the Data Center...
Efciency And Availability From Rack To Row To Room To Building
-
7/29/2019 Schneider Datacenter
4/16
4
Schneider Electric Solutions | Deliveing the Gaya Advantage
When Power is Mission-Critical
Mission-critical businesses cant always trust thepower grid to supply energy. Rather, they requirespecialized equipment to meet their critical powerneeds in addition to normal power distribution
equipment. This often includes automatic transfersystems, UPS systems, on-site generation, emergencypower equipment, ltered power distribution, surge
protection, static transfer, specialized coolingsystems and interfaces to other buildingmanagement systems. Designing, installing and
managing systems of this complexity is no smalltask.
Schneider Electric combines best-in-class productsand expertise with application-specic servicesto provide tightly coordinated, one-stop solutions
to businesses in which ultra-reliable power is arequirement not an option.
With hundreds of successful installations andgrowing, Schneider Electric specializes in meetingthe specic needs of data centers. Today, Square Dbrand equipment appears in the data centers of some
of the nations largest companies and governmentagencies. Whether Tier I or Tier IV, we design anddeliver an ultra-reliable, tiered system that addresses
even the greatest data center challenges.
People you can count on
To deliver reliable power, you need a reliable partner.
With expertise in product and system design, powermanagement and control, power system consultingand project management, our team ensures youroperation runs smoothly 7/24/365.
Our Experts:
n Serve you through every step of a projectn Deliver optimized solutions up to 33% faster on average
than a typical commercial project
n Create reliable systems that ensure peace of mind
Visit www.criticalpowernow.com
Schneider Electrics Square D brand is trusted by the nations leading dacenters, corporate enterprises, government institutions and healthcareservice providers. For more than a century, industry proessionals havechosen Square D brand products and services to maximize protabilityensure reliability and uptime and improve energy efciency.
Data Center Solutions
Power Distribution & Circuit Protection
Combine the power
o the industrys
leading brand in
electrical distribution
and circuit protection
with trusted global
energy management
solutions available only
rom Schneider Electric.
-
7/29/2019 Schneider Datacenter
5/16
5
1-800-GrAYbAr | gaya.com
Make the most of your energy!
Power is critical to a majority of todays businesses where smart energy combines reliability, efciency andsafety. Thats why Schneider Electric continues to deliver the leading brand in power distribution and circuit
protection products to the nations largest data centers.
Schneider Electrics Square D brand offers a completeline of high quality medium and low voltage powerdistribution products designed to ensure a reliablesupply of power in critical power applications,
including:
Drawout switchgear and switchboards
Power monitoring and control systems
Motor control centers
Transormers
Panelboards
Busway
Saety switches
Distribution and control components
Energy Efciency Solutions...
Schneider Electric's enterprise energy and powermanagement systems, variable frequency drives andenergy efcient transformers reduce operating costs.
And, our factory integration capabilities shortencycle times, save oor space and dramatically reduceinstallation costs. This interconnected solution
results in higher availability and better energysavings, all achieved while carefully controllingoperating expenses so you can put your money where
it matters most.
Visit www.criticalpowernow.com to learn more.
The Schneider Electric power domain connects it all... rom generators,transormers and switchgear to UPSs, breakers and PDUs...to delivercross-vendor interoperability.
-
7/29/2019 Schneider Datacenter
6/16
6
Schneider Electric Solutions | Deliveing the Gaya Advantage
Masterpact NW Circuit BreakerThe latest generation of Masterpact NW breakers provides more options and exibility to help you meet grea
needs for circuit protection reliability. Schneider Electric's innovative technologies provide higher interruptinratings, smaller footprint and more accessories than any other insulated case breaker.
n Complete product offering through 200k interruptingrating without fuses
n 800A to 5000A frames available
n Rated for all AC voltage systems through 635V
n ANSI short-time withstand ratings up to 100kA
n Simple, visual contact wear indicators
n Meets ANSI standard C37.13 and UL1066
n Full complement of eld-installable devices
n Selection of four interchangeable Micrologic trip unitswith PowerLogic power metering, communications andmonitoring capabilities available in advanced trip units
n Most common relay functions as dened by ANSI C37and C37.90 integrated into circuit breaker
n Electrically operated (optional)
n 4-pole breakers available
n Mechanical and electrical operations test withoutmaintenance
n Arc ash limiting breakers available
PowerPact D-Frame Mission-Critical Circuit BreakerThe Square D mission-critical breaker is designed specically for use as a mainbreaker in a Power Distribution Unit (PDU). Incorporating special thermal
magnetic selective tripping functions, the breaker assures that faults on a singlebranch circuit do not cascade causing a shutdown of an entire PDU.
Mission-critical circuit protection for your mission-critical application.
n Cost-effective alternative to electronic circuit breakers
n High level selective coordination provides maximum thermal-magnetic circuitprotection with minimal circuit interruption
n Unparalleled high magnetic withstand rating helps to prevent outages and minimizesdowntime
n Wide range of ampacities available to meet the unique needs of specic power systems
n Factory preset magnetics take the guesswork out of breaker adjustments
n Field-installable accessories permit easy customization using optional devicesincluding shunt trips, under voltage, auxiliary switches, bell alarm and terminations
n Available in both unit mount and I-Line panelboard construction for easy installation
n UL 489 Listed and CSA Certied
Data Center Solutions
Power Distribution & Circuit Protection
Mastepact NW Cicuit beake
Rated or use on battery UPS systems, transit applications and
DC backup systems in power plants and substations.
PowePact D-fame Mission-Citical Cicuit beake
High-perormance circuit protection and coordination or mission-critical power applications
-
7/29/2019 Schneider Datacenter
7/16
7
1-800-GrAYbAr | gaya.com
Make the Most of Your Energy!
PowerZone 4 LV SwitchgearThe primary advantages found in ANSI-rated switchgear are the
structure and breaker short-time withstand ratings (short circuitcurrent withstand for 30 cycles). When properly adjusted, this
allows main and feeder breakers to coordinate with downstreamprotective devices to insure the device closest to the faultclears rst.
This is very important when trying to coordinate with downstreammain breakers in UPSs, switchgear or other downstream devices.In addition to short-time withstand ratings, other benets such
as 100% rated breakers (from 800A to 5000A frames), drawoutconstruction and maintainability for extended life make lowvoltage switchgear the primary choice in data centers.
n Small, exible footprint
n Extended maintenance intervals
n Segregated access to all wiring
n Easy addition of smart functionality, including communicationsinterfaces, power monitoring and control capability
n Available up to 5000A bus ratingn Micrologic trip units with power monitoring to control
communications
n Optional PLC-based auto transfer schemes
n Optional Transparent Ready communications with PowerLogic
n Optional Surgelogic TVSS
n Differential ground fault option for 4W systems with multiplesources
n Arc ash application options
PoweZone 4 Low Voltage Switchgea
With Masterpact NW/NT Circuit Breakers...the proven,reliable and durable switchgear required or criticalpower applications.
QED-6 rea-ConnectedSwitchoad
With Masterpact NW/NT and Powerpactbreakers...the price-competitive, eature-richpower distributionsolution or data centers.
QED-6 Rear-Connected Switchboards with Masterpact NW/NT andPowerpact C & D BreakersFeatures individually mounted, drawout Masterpact circuit
breakers rated through 5000A. QED-6 switchboards withMasterpact NW UL 489 Listed circuit breakers give Square Dthe price-competitive, feature-rich advantage in power distributionsolutions for a variety of applications.
n Drawout construction is required for quick circuit breakerchange-out
n System requirements call for circuit breakers to close within 5-cycles
n Stored energy circuit breakers are required for reliability
n Front access to control wires is desired for ease of installation,maintenance, and upgrade
n Circuit breaker compartmentalization required for system integrity
n Segregation of circuit breaker compartments from bus and cablecompartments required for equipment isolation
Complex data center
subsystems standardizedor engineered to
your specication
> Switchgear
> UPS
> Building automation
> Cooling systems
-
7/29/2019 Schneider Datacenter
8/16
8
Schneider Electric Solutions | Deliveing the Gaya Advantage
Data Center Solutions
Power Monitoring
What you know about your data center and equipment can provide timely information and corrective responthat reduces risk and administration costs.
Square D PowerLogic systems from Schneider Electric act like a layer of intelligence across all
energy assets spanning power, building and facility systems.
Timely, relevant data is delivered to anyone that needs it, anywhere they are. It ts seamlessly with your
workow, and integrates tightly with other Schneider Electric power and automation solutions. PowerLogicsolutions are highly scalable, letting you add modular components or upgrade your systems affordably asrequired.
PowerLogic solutions result in signicant savings and a quick return on your investment. We pride ourselveson reliable products, innovative systems, expert engineering services and our ability to provide single-source
energy and power management solutions.
Its not just a concept to us, but rather a legacy and a promise for companies that seek an edge inproductivity. Thats why leaders turn to Schneider Electric.
Full support or PowerLogic devices
including the CM4 series, BCPM andMicrologic Trip Unitn Real-time data
n Waveform captures
n Onboard alarms and events
High-perormance real-time powermonitoring and control solutionn 1s response time
n 1ms sequence of event recording andalarming
Scalable to any application sizen +2000 devices
n +200k tags
Redundant system architecture
n I/O server hot/standby redundancy: dataacquisition uninterrupted even if PC fails
n Self-healing ring and double-ring technology
Outstanding System Reliabilityn Powerful automation for operational
continuity
n Comprehensive alarm/alert management for
fast network recovery in case of incident
n Operational safety & traceability of all
actions undertaken on the system
n Ideal for electrical distribution control
n Load shedding
n Load sharing
n ATO (Auto Throw Over)
n Interlocking
n Peak shaving
Power Monitoring Solutions
-
7/29/2019 Schneider Datacenter
9/16
9
1-800-GrAYbAr | gaya.com
Make the Most of Your Energy!
Energy Efciency and Cost SavingsReducing energy costs through increased
energy efciency can be implemented ina number of ways. What is often lacking
is the infrastructure to measure thesuccess of your energy efciency strategies.
Through data modeling and presentation
software, it is possible to gain insightregarding the effectiveness of each energyreduction technique instituted.
With Schneider Electrics Square DPowerLogic ION EEM enterprise energymanagement software combined with our
expert services, we unite business andenergy strategies to deliver the actionableintelligence necessary for a complete energy
and emissions management program.
Expose the true drivers o energy efciency
Schneider Electric delivers a holistic approach to integrate all relevant inputs including data from existingfacility-level power, process and building management systems, and weather and real-time pricing feeds.
Account or all energy sources, electrical losses and end use loadingn Establishing relevant benchmarks by measuring calculating and normalizing energy use
n Cost allocation for all energy sources with multiple calculation methods including cost/sq. ft., metered valuesor other set tariffs
Leverage accurate and reliable data rom across your entire enterprise, personalized or each stakeholdern Establish best practices and enable sound nancial and operational decisions
n Validate capital investments with energy simulation modeling based on actual equipment or building performance
Model and analyze energy perormance in multiple dimensions o consumption, emissions, cost, time andqualityn Represent the data as energy metrics: Power Usage Effectiveness (PUE), Data Center Efciency (DCE) and
Greenhouse Gas (GHG) emissions
n Track internal Key Performance Indicators (KPIs) such as kW per CFM for cooling loads, total energy cost per squarefoot or other energy cost characterizations
n Predict system energy usage to model potential changes what if scenarios such as equipment changeouts orraised-oor additions
n Pinpoint opportunities with the highest ROI and verify success and optimize procurement
-
7/29/2019 Schneider Datacenter
10/16
10
Schneider Electric Solutions | Deliveing the Gaya Advantage
Power Monitoring and AnalysisData center contracts are a commitment to uptime. Although infrequent, data centers do experience outagesthat are typically due to: human error, improper failover, overheating or equipment issues related to a PDU,
breaker or power strip. When a problem does occur, disaster avoidance and quick recovery is key.
PowerLogic System Manager and ION Enterprise power monitoring software plays a big part in theoperational success of data centers. Responsible for automatically collecting circuit monitor and power mete
information, the power monitoring software alerts facility management to potential power quality problemsthat could lead to downtime if left undetected.
Data Center Solutions
Power Monitoring
PowerLogic BCPM Branch CircuitPower Meters
The PowerLogic BCPM is a highly accurate, full
featured metering product designed for the unique,multi-circuit and minimal space requirements of ahigh performance Power Distribution Unit (PDU) orRemote Power Panel (RPP).
The BCPM monitors up to 84 branch circuits andthe incoming power mains, providing information on
a complete PDU. Full alarming capabilities ensurethat potential issues are dealt with before theybecome problems.
Unlike products designed for specic hardware,the exible BCPM ts any PDU or RPP design and
supports both new and retrot installations. Withexceptional dynamic range, accuracy and optionalfeature sets, it meets the energy challenges ofmission-critical data centers.
Receive WARNINGS rom electrical events:> Voltage Sag/Swell, Transients (service entrance
and UPS output)
> Overload alarms from dedicated PDU branch
circuit monitoring> Real-time information for PDU fail-over (capacity)
concerns
> Measure number of 9s for uptime
> Equipment status monitoring: main meter,generator, ATS, UPS, STS, PDU, CRAC, etc.
Identiy the source o power quality disturbances:> Disturbance direction detection, a patented
feature, helps locate the source of a disturbanceby indicating whether it's occurrence upstream ordownstream of the meter
> Direction information and a statistical condencelevel are added to the event log and displayedas an alarm in PowerLogic power monitoringsoftware
Improved Reliability or Critical Power Applications
-
7/29/2019 Schneider Datacenter
11/16
11
1-800-GrAYbAr | gaya.com
Make the Most of Your Energy!
Sequence o Events Recording (SER)When equipped with sequence
of event recording, PowerLogicsystems also aid in precisemillisecond time stamped event
identication that gives a rootcause analysis necessary to takecorrective action to avoid future
incidents. By seeing what wentrst, and when, the amount oftime to diagnose electrical system
maladies can be cut to minutes,potentially saving millions ofdollars in downtime, and help
quantify the issue to avoid italtogether.
Square D PowerLogic Systems> Reduce downtime by detecting voltage
disturbances before or while theyoccur
> Reduce energy costs by managingpeak usage, improving power factorsand automatic load-shedding tooptimize utility contracts
> Improve reliability with transparencyof root causes or interruption andsequence of events
Electrical Equipmentn High Voltage
n XMFR alarms
n Switch position, blown fuseindication
n Protective Relays
n Relays (under frequency, overfrequency, current unbalance,voltage unbalance, undervoltage and over voltage)
n Low voltage distribution
n TVSS, blown fuse indication
n Breaker status (open, closed,tripped and breaker cradleposition)
ATS and STSn Status (aux. contact)
n Phase synch alarm
n Summary alarm
UPS and PDUn Status (trip or switch to
bypass)
n Summary alarm (aux.contact)
Generation Busn Generator differential Relay
87
n Breaker status
n Lockout relay
n Voltage phase balancen Ground fault
n Reverse power
n DC bus voltage relay
n Battery charger alarms
PowerLogic MetersLocated at main incoming power, UPS output, generator,
paralleling switchgear and throughout the data center,PowerLogic meters provide:
nDisturbance direction detection Indicates upstream ordownstream occurrence to locate the source of a disturbance inrelation to the meter and provides a level of condence
nHarmonic power fows Meters at the point of common couplingmeasure harmonic power ow to help determine whether harmoniccurrents originated inside the facility or on the utility grid
nImpulsive transient detection (CM4000T) Captures extremelyshort duration (200 nanosecond) voltage events to determine thesource and veries the adequacy of transient mitigation equipment
nWaveform capture Allows you to nd the toughest powerproblems to the 255th harmonic
nFlexible I/O for pulse counting Shift energy logging, energytrending, forecasting and more
-
7/29/2019 Schneider Datacenter
12/16
12
Schneider Electric Solutions | Deliveing the Gaya Advantage
Integrated Solutions Move You Into the FutureTechnology continues to evolve faster than your
physical environment can. Server rooms were neverdesigned to handle the high-density power, coolingand management challenges of todays trends such
as consolidation, virtualization and blade technology.The higher the memory and processing speedsthat come with high-density computing require a
reliable, redundant, power back-up system as well asproper cooling, while monitoring key environmentsis essential to managing increasing densities.And virtualization means that power and cooling
availability becomes even more critical.
On top of that, your server room becomes more
crucial to your business goals every day. But doesthat mean you have to re-engineer your old serverroom or spend a fortune building a dedicated data
center? No.
Introducing the Total Server Room Solution
Easily deployed, rack-based and reliable, the APC
by Schneider Electric Total Server Room Solutionincludes power, cooling, monitoring and managementcomponents all the elements you need, bundled
together.
Everything has been pre-engineered to worktogether and integrate seamlessly with your existing
equipment. Its plug-and-play approach ts intomost any space: no need for additional coolingcongurations; expensive, mechanical re-engineering;
or total build-outs. The modular, pay-as-you-growdesign lets your server rooms keep pace with ever-changing demands.
Data Center Solutions
Cooling & Efciency
Schneider Electrics APC InraStruxure ully integrates power, cooling, rack,management, security and services. This on-demand architecture allowsthe selection o standardized components to create a solution throughmodular and mobile congurations. InraStruxure is available or any ITenvironment, rom wiring closets to large data centers.
Schneider Electrics
APC InraStruxure
ully integrates
power, cooling, rack,
management, security
and services.
-
7/29/2019 Schneider Datacenter
13/16
13
1-800-GrAYbAr | gaya.com
Make the Most of Your Energy!
A Single Solution Solves a Multitude o ChallengesThe total server room solution is built on the exible
InfraStruxure architecture for a holistic approach,in an optimized rack-design for the reliability andhigh availability todays computing craves.
Cooling - for every scenario. Effective and energy-efcient InRow cooling units handle high-densityheat at its source, and unique, variable-speed fans
automatically adjust to meeting changing heat loads.
Power - to perform. Energy-efcient, ultra-reliable
Smart-UPS and Symmetra UPSs offer customersscalable runtime. And rack-mount power distributionunits (PDU) ensure that a wide variety of devise get
plugged in and powered.
Environmental monitoring and management -provides total remote control for your data center.
PoE-enabled temperature sensors let you keep an eyeon conditions.
Enclosures - with superior door ventilation. Vendor-neutral NetShelter SX racks handle high-densityairow and power needs and neat cable management
capabilities.
Easy to Manage
Because APCs total server room solutions are pre-engineered, the complexity and hassle of conguringserver room needs are eliminated. So youll have
more time to run your business and still keeppace with the ever-changing demands of the ITenvironment. APCs total server room solutions are:
Easy to congure: Web-based tools enable easyproduct selection and solution conguration;
multiple channel partners offer a wide range ofservice options.
Easy to install: Drop in anywhere-raised or non-
raised oor, IT space or non-IT space. Installationservices are available too.
Easy to operate: APC solutions include simple,easy-to-use software to aid in all power and cooling
decisions.Future-Proo ,Too
APCs total server room solution offers a quiet,secure, cooled enclosure for environments without
dedicated space, creating a proper IT ecosystem withunprecedented visibility and power protection fortoday, tomorrow and beyond. Weve eliminated the
building and facility management challenges so youcan have a closet anywhere!
-
7/29/2019 Schneider Datacenter
14/16
14
Schneider Electric Solutions | Deliveing the Gaya Advantage
The 4Cs o Energy ManagementSimple changes to the way your organization approaches energy use can help recoup your losses - and put
those wasted dollars back into your budget.
Data Center Solutions
Cooling & Efciency
Data centers are more efcient by design, eliminating the outdated circle
the wagons approach to room design by closely connecting the heat
generation to the cooling2CloseCoupledCooling:
Containment o the hot air created by high density applications such
as blade servers leads to a predictable, repeatable power and cooling
architecture
3Containment:
Management sotware to ensure quick and efcient technology rollouts
without surprises and downtime. Go rom design to management using
one powerul platorm across all your power and cooling architecture.4CapacityManagement:
Award-winning solutions rom the industrys number one brands, APC an
MGE UPS Systems by Schneider Electric, backed by the industrys broades
service ootprint to ensure your best choice in power, racks and cooling1Best-in-ClassComponents:
-
7/29/2019 Schneider Datacenter
15/16
15
1-800-GrAYbAr | gaya.com
Make the Most of Your Energy!
The APC Trade-O Tools by Schneider ElectricAPCs Trade-off tools help you to make informed decisions BEFORE you design your data center. Quickly
determine costs, efciency and carbon footprint by:
Data Center Capital CostsPower Cooling and Efciency
Carbon Footprint
W Size W Density
W Redundancy W Architecture
Thought Leadership
-
7/29/2019 Schneider Datacenter
16/16
Gaya Woks to You Advantage. Built on a oundationo quality and reliability, Graybars customized data center
solutions bring you a high level o perormance and a low
total cost o ownership. As a valuable and trusted supply
chain expert, we are dedicated to bringing you technology-
driven solutions and unrivaled customer service. Our
ultimate goal is to help you overcome operationalchallenges and support your needs in an ever-changing
business environment.
To learn more, visit our website at graybar.com/datacenteror call us at 1-800-GRAYBAR (472-9227).
Thank you to: Schneider Electric, Square D, APC and Pelco #802330 10-173 (07/10)