IDES CANADA INC. 431 Alden Road. #3 Markham, ON, L3R 3L4 CONTACT US Local: 416.479.0078 Toll-Free 1.888.988.IDES (4337) WEB AND EMAIL Email: [email protected] www.scentroid.com FOLLOW US RECYCLED PAPER SM100i Scentroid SM100i Intelligent Personal Olfactometer The SM100i can conduct odour measurements from: - Ambient air without any additional sampling equipment - Directly from smoke stacks or lter inlets - Directly from ux chambers or wind tunnels - Air samples stored in sampling bags - Screen Panellist using N-butanol and YES/NO method in full accordance to EN13725. ACCURACY The SM100i is an olfactometer with an unprecedented accuracy : - Micro-computer controlled dilution range from 2 to 30,000 OU - Meets EN13725 and ASTM E679 for olfactometer design - Keep noses sensitive even in the harshest ambient odours - Constant presentation air ow (not dependant on SniRate) - Odourless diluting air from compressed air tanks COMPLETE AUTOMATION entroid SM100i represents the next evolution in personal olfactometry. This intelligent instrument can conduct full odour analysis includingYES/No test mode in full accordance to the international EN13725 standard.The SM100i can analyze from a sample bag or be deployed in the eld for direct olfactometry and ambient odour measurement. In addition to odour concentration (in OU) the SM100i S HOW IT WORKS The SM100i draws a sample of ambient air via venturi pump and dilutes it using fresh odour less air from a compressed air tank. A micro-controller adjusts the dilution ratio and interacts with the panellist though a touch screen tablet to conduct YES/No test mode and automatically calculate the odour concentration. MEETING THE EN13725 STANDARD The SM100i meets all criteria for the EN13725 odour standard including: - YES/NO Test method - N-butanol Screening - 20 Litters/min presentation - All stainless steel or PTFE wetted materials. CAPABILITIES The SM100i takes out the guess work from personal olfactometry. The instrument will automatically screen panellists and conduct Yes/No test mode to determine accurate odour concentration and hedonic tone. USE THE SM100i TO: - Conduct daily odour emission assessment - Determine odour mitigation eectiveness over time - Monitor emission compliance and conduct N-butanol screening with the use of the wearable OdoTracker can also automatically record Ammonia (NHx) and Hydrogen Sulphide (H2S) in real-time.

Transcript of Scentroid SM100 -...

IDES CANADA INC.431 Alden Road. #3Markham, ON, L3R 3L4

CONTACT US Local: 416.479.0078 Toll-Free 1.888.988.IDES (4337)

WEB AND EMAIL Email: [email protected] www.scentroid.com

FOLLOW US

RECY

CLED

PAP

ER

SM100i

Scentroid SM100iIntelligent Personal Olfactometer

The SM100i can conduct odour measurements from: - Ambient air without any additional sampling equipment - Directly from smoke stacks or filter inlets - Directly from flux chambers or wind tunnels - Air samples stored in sampling bags - Screen Panellist using N-butanol and YES/NO method in full accordance to EN13725.

ACCURACYThe SM100i is an olfactometer with an unprecedented accuracy : - Micro-computer controlled dilution range from 2 to 30,000 OU - Meets EN13725 and ASTM E679 for olfactometer design - Keep noses sensitive even in the harshest ambient odours - Constant presentation air flow (not dependant on Sniff Rate) - Odourless diluting air from compressed air tanks

COMPLETE AUTOMATION

entroid SM100i represents the next evolution in personal olfactometry. This intelligent instrument can conduct full odour analysis including YES/No test mode in full accordance to the international EN13725 standard. The SM100i can analyze from a sample bag or be deployed in the field for direct olfactometry and ambient odour measurement. In addition to odour concentration (in OU) the SM100i

S

HOW IT WORKSThe SM100i draws a sample of ambient air via venturi pump and dilutes it using fresh odour less air from a compressed air tank. A micro-controller adjusts the dilution ratio and interacts with the panellist though a touch screen tablet to conduct YES/No test mode and automatically calculate the odour concentration.

MEETING THE EN13725 STANDARD The SM100i meets all criteria for the EN13725 odour standard including: - YES/NO Test method - N-butanol Screening - 20 Litters/min presentation - All stainless steel or PTFE wetted materials.

CAPABILITIES

The SM100i takes out the guess work from personal olfactometry. The instrument will automatically screen panellists and conduct Yes/No test mode to determine accurate odour concentration and hedonic tone.

USE THE SM100i TO: - Conduct daily odour emission assessment- Determine odour mitigation effectiveness over time- Monitor emission compliance and conduct N-butanol screening

with the use of the wearable OdoTracker can also automatically record Ammonia (NHx) and Hydrogen Sulphide (H2S) in real-time.

SPECIFICATIONS Manufacturer IDES CANADA INCModel SM100iAir Supply Capacity 20 Min base / 40 Min with dual air tank option Number of samples per tank refill 10-15 Dilution range 2 – 30,000 (2^15)Dilution principle Stainless Steel EductorNumber of dilution steps 15 (adjustable range)Selectable ranges 2-101; 4-678; 44-656; 2-3600; 2000-30,000Interface with mobile device Bluetooth Battery Rechargeable Lithium-ion with 36 hour capacity per chargePresentation device for direct olfactometry (In-Field) Half-face PTFE maskPresentation device for delayed olfactometry (Laboratory ) PTFE coated sniffing portWetted Material Stainless steel and PTFEWeight Kg/(lb) 3.5 (8)

IDES CANADA INC.431 Alden Road. #3Markham, ON, L3R 3L4

CONTACT US Local: 416.479.0078 Toll-Free 1.888.988.IDES (4337)

WEB AND EMAIL Email: [email protected] www.scentroid.com

FOLLOW US

RECY

CLED

PAP

ER

SM100i

N-BUTANOL SENSITIVITY KIT IN LAB ANALYSIS KIT

Sample

Lab

Results

(OU)

SM110C

Results

(OU)

1 116 94

2 108 164

3 139 131

4 201 219

5 1846 1441

DIRECT OLFACTOMETRY A part of EN13725, Direct Olfactometry refers to the measure-ment of odours directly from the source to eliminate odour degradation caused by sample storage and transportation. Direct olfactometry provides immediate results making it ideal for testing and maintaining any odour abatement system.SM100i provides an ideal instrument for conducting direct olfac-tometry. The sample input port can be connected to: a stack, flux chamber, wind tunnel, static hood, or any other source sampler.

AMBIENT ODOUR MONITORINGAmbient odour monitoring using the SM100i provides many benefits such as -Verifying dispersion modeling -Conducting odour assessment for Total Odour Management System -Odour complaint follow up -Measuring fugitive sources - Indoor air quality

ODOTRACKER

COMPARISON TO FULL SCALE LABORATORY

The SM100i along with the OdoTracker can not only provide ac-curate odour concentration but can also provide ppb level reading of H2S and Ammonia, the most common odour causing chemicals. This information is automatically collected by the SM100i from the wearable sensor OdoTracker.

*Comparative study between SM100 and EN13725 odour laboratory