SCAP ENERGY
MANAGEMENT COMMITTEE
Renewable Energy Sources: Wind Power
PRESENTED BY:
ADHAM ALMASRI, P.E., M.S.
SENIOR ENGINEER-INLAND EMPIRE
UTILITIES AGENCY
![Page 2: SCAP ENERGY MANAGEMENT COMMITTEEscap1.org/POTW Reference Library/110428 IEUA wind power ppt.pdf · scap energy management committee renewable energy sources: wind power presented](https://reader034.fdocuments.in/reader034/viewer/2022042521/5f6beae798a06723ff59f10b/html5/thumbnails/2.jpg)
BACKGROUND
• IEUA has been considering the benefits of providing clean and renewable energy with potentially more valuable green attributes which IEUA can use to offset other high-Carbon emitting operation.
• IEUA analyzed the technical feasibility of utilizing on site power generation systems for the following reasons:
1) Low cost per kilowatt hour
2) Environmentally friendly
3) Reliability with minimal maintenance.
![Page 3: SCAP ENERGY MANAGEMENT COMMITTEEscap1.org/POTW Reference Library/110428 IEUA wind power ppt.pdf · scap energy management committee renewable energy sources: wind power presented](https://reader034.fdocuments.in/reader034/viewer/2022042521/5f6beae798a06723ff59f10b/html5/thumbnails/3.jpg)
Agency-Wide Energy
Portfolio
56%
7%
24%
10%
3%
2013
Imported
Fuel Cell (Natural Gas)
Fuel Cell (Biogas)
Solar
Wind
74% 1%
15%
10%
Current
Imported
ICE (Natural Gas)
ICE(Biogas)
Solar
![Page 4: SCAP ENERGY MANAGEMENT COMMITTEEscap1.org/POTW Reference Library/110428 IEUA wind power ppt.pdf · scap energy management committee renewable energy sources: wind power presented](https://reader034.fdocuments.in/reader034/viewer/2022042521/5f6beae798a06723ff59f10b/html5/thumbnails/4.jpg)
Goals & Objectives
• IEUA’s goal is to maximize renewable energy, optimize
energy usage and become gridless by 2020
• Electric demand is approximately 8 MW avg.(12 MW
peak)
• Renewable Energy includes:
• Solar Power (completed)
• Wind Power
• Fuel cells
• IEUA executed Power Purchase Agreements (PPA) for
receiving three renewable energy sources.
![Page 5: SCAP ENERGY MANAGEMENT COMMITTEEscap1.org/POTW Reference Library/110428 IEUA wind power ppt.pdf · scap energy management committee renewable energy sources: wind power presented](https://reader034.fdocuments.in/reader034/viewer/2022042521/5f6beae798a06723ff59f10b/html5/thumbnails/5.jpg)
Wind Environment
Minimum 8 mph (4 m/s) wind speed for turbine power
generation cut-in
Local area wind speed averages 13 mph
IEUA/IERCA in Class 3 Area
(Avg. speed 13 mph)
Wind Speed Class
National Renewable Energy Laboratory Map
![Page 6: SCAP ENERGY MANAGEMENT COMMITTEEscap1.org/POTW Reference Library/110428 IEUA wind power ppt.pdf · scap energy management committee renewable energy sources: wind power presented](https://reader034.fdocuments.in/reader034/viewer/2022042521/5f6beae798a06723ff59f10b/html5/thumbnails/6.jpg)
Proposed 900 kW Wind Turbine
Location
Regional WWTP-
4/IERCF Complex
![Page 7: SCAP ENERGY MANAGEMENT COMMITTEEscap1.org/POTW Reference Library/110428 IEUA wind power ppt.pdf · scap energy management committee renewable energy sources: wind power presented](https://reader034.fdocuments.in/reader034/viewer/2022042521/5f6beae798a06723ff59f10b/html5/thumbnails/7.jpg)
RP4 Wind Turbine PPA
Deal Points
• Provider: Foundation Windpower
• PPA term:20 years
• PPA price: $0.085 per kWh, fixed 2.0% escalation for 2 years, and
3.0% thereafter
• Estimated Annual Power Production: 2190 MW-Hr
• Benefit of low O&M Costs
• Lowest unit cost among all on-site power generation systems
![Page 8: SCAP ENERGY MANAGEMENT COMMITTEEscap1.org/POTW Reference Library/110428 IEUA wind power ppt.pdf · scap energy management committee renewable energy sources: wind power presented](https://reader034.fdocuments.in/reader034/viewer/2022042521/5f6beae798a06723ff59f10b/html5/thumbnails/8.jpg)
No development cost
No capital investment
No maintenance cost
Stable and predictable power cost
Over 1. 5 million kWh generated annually with zero air emissions
Will displace 6,125,000 lbs of carbon = to planting 8,624 trees or removing 528 cars from the road
Wind turbine is a visible symbol of environmental stewardship
Power generated will be supplied to RP-4 and IERCF with the ability to control the amount of power to be provided to each facility (SEPARATE METERS)
Small footprint compared to solar
Minimal IEUA / IERCA
Expense
PPA BENEFITS
![Page 9: SCAP ENERGY MANAGEMENT COMMITTEEscap1.org/POTW Reference Library/110428 IEUA wind power ppt.pdf · scap energy management committee renewable energy sources: wind power presented](https://reader034.fdocuments.in/reader034/viewer/2022042521/5f6beae798a06723ff59f10b/html5/thumbnails/9.jpg)
9
Wind Equipment – Efficient Use of Real Estate
Solar PV – 1.0 MW Wind – 1.0 MW
= 6 to 8 acres = ~.06 acres (50`x50`)
Wind turbine
could almost fit in
½ of an end zone
PV solar requires
about
9 football
fields
![Page 10: SCAP ENERGY MANAGEMENT COMMITTEEscap1.org/POTW Reference Library/110428 IEUA wind power ppt.pdf · scap energy management committee renewable energy sources: wind power presented](https://reader034.fdocuments.in/reader034/viewer/2022042521/5f6beae798a06723ff59f10b/html5/thumbnails/10.jpg)
$120,000.00
$140,000.00
$160,000.00
$180,000.00
$200,000.00
$220,000.00
$240,000.00
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
YEARS
CO
ST
/YE
AR
$0.085/kWh
$0.15/kWh
COST OF POWER – 20 Year Example
Current Power Rate at $0.13/kWh
![Page 11: SCAP ENERGY MANAGEMENT COMMITTEEscap1.org/POTW Reference Library/110428 IEUA wind power ppt.pdf · scap energy management committee renewable energy sources: wind power presented](https://reader034.fdocuments.in/reader034/viewer/2022042521/5f6beae798a06723ff59f10b/html5/thumbnails/11.jpg)
11
PPA Base Model – Reduces Costs Zero Payback Period
• All upfront and ongoing expenses paid by Provider • Minimal costs incurred by the customers during permitting, design and construction. • Project returns positive cumulative cash flow on Day One
Significant Cumulative Savings
• SCE prices increases historically, escalate at 5%-6% annually • Customers may save millions of dollars in energy costs
![Page 12: SCAP ENERGY MANAGEMENT COMMITTEEscap1.org/POTW Reference Library/110428 IEUA wind power ppt.pdf · scap energy management committee renewable energy sources: wind power presented](https://reader034.fdocuments.in/reader034/viewer/2022042521/5f6beae798a06723ff59f10b/html5/thumbnails/12.jpg)
Q: What expenses will the customer incur?
A: Minimal expenses to coordinate the planning, design and construction. May
have some internal legal or closing costs. Customer leases ~ 50 sq. ft. parcel
for $1 per year over the 20 year project life. Turbines are delivered, installed,
and commissioned at Provider’s expense.
Q: Who pays repair, maintenance, and operational costs?
A: Provider pays all costs associated with operating and maintaining the
turbines for the full project lifetime.
Q: How does IEUA (customer)save money?
A: All the wind power is sold to the customer at a discount to their utility rates.
This results in an energy charge savings, and in some cases demand charge
savings too.
Q: What happens at the end of the 20 year project life?
A: Provider will extend the power purchase arrangement or “re-power” with the
best available technology. The customer may also purchase the facility at the
then fair market value.
Frequently Asked Questions
![Page 13: SCAP ENERGY MANAGEMENT COMMITTEEscap1.org/POTW Reference Library/110428 IEUA wind power ppt.pdf · scap energy management committee renewable energy sources: wind power presented](https://reader034.fdocuments.in/reader034/viewer/2022042521/5f6beae798a06723ff59f10b/html5/thumbnails/13.jpg)
Suitability of site
Environmental Aesthetics – height
Permitting - compliance with CEQA Process and FAA
Real Estate: Site Lease within the PPA.
PROJECT CONSIDERATIONS
![Page 14: SCAP ENERGY MANAGEMENT COMMITTEEscap1.org/POTW Reference Library/110428 IEUA wind power ppt.pdf · scap energy management committee renewable energy sources: wind power presented](https://reader034.fdocuments.in/reader034/viewer/2022042521/5f6beae798a06723ff59f10b/html5/thumbnails/14.jpg)
FAA: Determination of No Hazard
CEQA: Negative Declaration
-Advertisement in newspaper for two Sundays, Cities within 5-mile radius of the site
for 30 days
PROJECT PERMITS
![Page 15: SCAP ENERGY MANAGEMENT COMMITTEEscap1.org/POTW Reference Library/110428 IEUA wind power ppt.pdf · scap energy management committee renewable energy sources: wind power presented](https://reader034.fdocuments.in/reader034/viewer/2022042521/5f6beae798a06723ff59f10b/html5/thumbnails/15.jpg)
1 2
3
4
5
6
7
PROPOSED
WIND
TURBINE
LOCATION
1 mile
1 mile 1 mile RENDERINGS OF THE WIND TURBINE at RP-4
1 mile
1 mile
1 mile
1 mile
1 mile
1 mile
1 mile
1 mile
1 mile 1 mile 1 mile 1 mile
![Page 16: SCAP ENERGY MANAGEMENT COMMITTEEscap1.org/POTW Reference Library/110428 IEUA wind power ppt.pdf · scap energy management committee renewable energy sources: wind power presented](https://reader034.fdocuments.in/reader034/viewer/2022042521/5f6beae798a06723ff59f10b/html5/thumbnails/16.jpg)
Rendering: South of Arrow Rt. on 15 Freeway (north); View:
Southeast
![Page 17: SCAP ENERGY MANAGEMENT COMMITTEEscap1.org/POTW Reference Library/110428 IEUA wind power ppt.pdf · scap energy management committee renewable energy sources: wind power presented](https://reader034.fdocuments.in/reader034/viewer/2022042521/5f6beae798a06723ff59f10b/html5/thumbnails/17.jpg)
Wind Turbine Height Comparison
Relian
t
Power
Stack
Propos
ed Wind
Turbine
Perso
n
SCE
Tower in
Reliant
SCE
Tower
on
Etiwand
a
Larger
Availabl
e Wind
Turbine
![Page 18: SCAP ENERGY MANAGEMENT COMMITTEEscap1.org/POTW Reference Library/110428 IEUA wind power ppt.pdf · scap energy management committee renewable energy sources: wind power presented](https://reader034.fdocuments.in/reader034/viewer/2022042521/5f6beae798a06723ff59f10b/html5/thumbnails/18.jpg)
1.0-MW Wind Turbine at RP-4
May-June 2011 -- Foundation work June 2011 -- Construction & Erection July.-Sep. 2011 -- Electrical & Interconnection October 2011 – Commissioning
![Page 19: SCAP ENERGY MANAGEMENT COMMITTEEscap1.org/POTW Reference Library/110428 IEUA wind power ppt.pdf · scap energy management committee renewable energy sources: wind power presented](https://reader034.fdocuments.in/reader034/viewer/2022042521/5f6beae798a06723ff59f10b/html5/thumbnails/19.jpg)
QUESTIONS?