Saturn Cutoff LED [SACL] selux Cutoff LED-- - - - ... driver for DMY option is Philips Xitanium...

12
Page 1 of 12 (Rev. 12/2017) SACL_SSv3.9 In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions. Selux Corporation © 2017, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us Approvals Product Modifications Please list modification requirements for review by factory: LED WARRANTY 5 YEAR IP65 Saturn Cutoff LED - - - - - - - Pole Order Code: - - - Series Height Finish Options - Project: Type: Qty: Date: Customer: Date: Series SACL Saturn Cutoff LED Light Engine LG4500 500 mA/51W LG4700 700 mA/65W LG4105 1050 mA/101W CCT Optics R1 Type I Distribution R2 Type II Distribution R3 Type III Distribution R5 Type V Distribution Mounting 1 Single 1A Single Arm Mount 2 Double W Wall Mount Power Cord Length Finish WH White BK Black BZ Bronze SP Specify Premium Color Voltage 120 208 240 277 347 * 480 * * Equipped with step-down transformer Options SACL For other CCT please consult factory SV Silver Order Code: 30 1 3000K 35 3500K 40 4000K 50 5000K 8 2,3 10 2,3 12 2,3 14 2,3 16 2,3 18 2,3 XX 2,3 8’ 10’ 12’ 14’ 16’ 18’ XX’ 2 For 1 mounting use the pole height 3 For 1A or 2 mounting use the pole height +2 DS 9 No Uplight Finish HS House Side Shield (180°) FS 4 Single Fusing PCT Photocell Tenon See p. 7 for details DMY 5 Dimming (Dynadim) See p. 7 for details DM 7,8 Dimming (0-10V) 4 Not available with 347 or 480 5 LG4700 only 6 120, 240, 277 only 7 LG4700, LG4105 only 8 HL or DM 9 IDA Approved with 3000K CCT 1 IDA Approved HLxx 6,7,8 Hi-Lo Switching See p. 6 for details Motion Sensor w/ Optional Photocell (Meets Title 24 Requirements) See Pole Spec Sheet for Order Code

Transcript of Saturn Cutoff LED [SACL] selux Cutoff LED-- - - - ... driver for DMY option is Philips Xitanium...

Page 1: Saturn Cutoff LED [SACL] selux Cutoff LED-- - - - ... driver for DMY option is Philips Xitanium Driver. 6. ... POLES AND COLUMNS FOR SENSOR MOUNTING ORIENTATION

Page 1 of 12(Rev. 12/2017)SACL_SSv3.9

In a continuing eff ort to off er the best product possible, we reserve the right to change, without notice, specifi cations or materials that in our opinion will not alter the function of the product. Specifi cation sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.

Selux Corporation © 2017, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us

ApprovalsProduct Modifi cationsPlease list modifi cation requirements for review by factory:

LED WARRANTY

5YEAR IP65

Saturn Cutoff LED

- - - - - - -

Pole Order Code: - - -

Series Height Finish Options

-

Project:

Type: Qty:

Date: Customer:

Date:

Series SACL Saturn Cutoff LED

Light Engine LG4500500 mA/51W

LG4700700 mA/65W

LG41051050 mA/101W

CCT

Optics R1Type IDistribution

R2Type IIDistribution

R3Type IIIDistribution

R5Type VDistribution

Mounting 1Single

1ASingle ArmMount

2Double

WWall Mount

Power CordLength

Finish WHWhite

BKBlack

BZBronze

SPSpecify Premium Color

Voltage 120 208 240 277 347* 480* *Equipped with step-down transformer

Options

SACL

For other CCT please consult factory

SV Silver

Order Code:

301

3000K353500K

404000K

505000K

82,3 102,3 122,3 142,3 162,3 182,3 XX2,3

8’ 10’ 12’ 14’ 16’ 18’ XX’

2For 1 mounting use the pole height3For 1A or 2 mounting use the pole height +2

DS9

No UplightFinish

HSHouse SideShield (180°)

FS4

Single FusingPCTPhotocellTenonSee p. 7 for details

DMY5

Dimming(Dynadim)See p. 7 for details

DM7,8

Dimming(0-10V)

4Not available with 347 or 4805LG4700 only6120, 240, 277 only7LG4700, LG4105 only8HL or DM9IDA Approved with 3000K CCT

1IDA Approved

HLxx6,7,8

Hi-Lo SwitchingSee p. 6 for details

Motion Sensor w/ Optional Photocell (Meets Title 24 Requirements) See Pole Spec Sheet for Order Code

Page 2: Saturn Cutoff LED [SACL] selux Cutoff LED-- - - - ... driver for DMY option is Philips Xitanium Driver. 6. ... POLES AND COLUMNS FOR SENSOR MOUNTING ORIENTATION

Page 2 of 12 (Rev. 12/2017) SACL_SSv3.9

In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.

Selux Corporation © 2017, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us

28 3/8” (720mm)

25” (636mm)

Saturn Cutoff LED

1. Luminaire Cover - Die cast aluminum cover made from low copper alloy, designed to ensure optimal thermal management for extra long life time of LED light engine.

2. Gasketing - (not shown) Continuous gasket provides weatherproofing, dust and insect con-trol at all fixture connections.

3. Luminaire Hood - Aluminum shade with white painted interior.

4. LED Array - (not shown) High flux LEDs mounted to PC boards and attached to alumi-num heat sink for maximum LED performance and life. CCT tolerance 1/4 step binning for 3000K, 3500K and 4000K and ANSI standard for 5000K. CRI minimum 80 for 3000K, 3500K and 4000K and typical 80 for 5000K. Complete light engine can be removed easily for future upgrade. LED light engine provides a reported lumen maintenance of 91% at 60,000 hours. L70 calculated greater than 73,000 hours.

5. LED Driver - LEDs are driven by RoHS com-pliant high-efficiency driver. Excellent for cold temperature starting and instant on. Standard driver for DMY option is Philips Xitanium Driver.

6. Hood Supports - Two aluminum arms support shade and optic assembly and attach to the die cast aluminum pole fitter (shown painted matte black for DS option).

7. Pole Fitter - Self-leveling, die-cast low-cop-per aluminum alloy, fitter base secured to pole with three, stainless steel, Allen head set screws. Fitter for 3 1/2” (90mm) O.D. poles.

8. Driver cover - Die cast aluminum cover made from low copper alloy, removes for tool-less ac-cess to driver. Driver secured to removable tray for ease of maintenance (shown painted matte black for DS option).

9. Surge Protector - (not shown) Designed to protect luminaire from electrical surge (10kA).

10. Hi-Lo Switching Option - (not shown) Please see p. 5 for details.

11. Power Cord - (not shown) Pre-installed at factory. Please specify power cord length in accordance to height of the pole. Add 2 feet to power cord length if double mounting (2) is specified.

Exterior Luminaire Finish - Selux utilizes a high quality Polyester Powder Coating. All Selux luminaires and poles are finished in our Tiger Drylac certified facility and undergo a five stage intensive pretreatment process where product is thoroughly cleaned, phosphated and sealed. Selux powder coated products provide excellent salt and humidity resistance as well as ultravio-let resistance for color retention. All products are tested in accordance with test specifications for coatings from ASTM and PCI.

Standard exterior colors are White (WH), Black (BK), Bronze (BZ), and Silver (SV). Selux premium colors (SP) are available, please specify from your Selux color selection guide.

5 Year Limited LED Luminaire Warranty - Selux offers a 5 Year Limited Warranty to the original purchaser that the Saturn Cutoff LED luminaire shall be free from defects in material and workmanship for up to five (5) years from date of shipment. This limited warranty covers the LED driver and LED array when installed and operated according to Selux instructions. For details, see “Selux Terms and Condition of Sale.”

Listings and Ratings: Luminaire and LED tested to IP65 and IESNA LM-79-08 standards. LED tested to LM-80 standards. Luminaire and LED tested at 25°C ambient temperature.

For LG4500 and LG4700, luminaire suitable for ambient temperatures of 55°C (130°F). For LG4105, luminaire suitable for ambient temperature of 45°C (113°F). Minimum op-erating temperature of luminaire at -35°C (-31°F).

NRTL Listed (i.e. UL, CSA)

Visit selux.us for our LED End of Life recycling policy.

Specifications

11” (279mm)7”

(178mm)

For further details, please see installation instructions.

SACL-1-XX-DS

1

7

3

8

6

5

Page 3: Saturn Cutoff LED [SACL] selux Cutoff LED-- - - - ... driver for DMY option is Philips Xitanium Driver. 6. ... POLES AND COLUMNS FOR SENSOR MOUNTING ORIENTATION

Page 3 of 12 (Rev. 12/2017) SACL_SSv3.9

In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.

Selux Corporation © 2017, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us

Saturn Cutoff LED

Motion Sensor Features

The Selux outdoor rated sensor incorporates Passive Infrared (PIR) technology for motion sensing and also includes a built in photocell. Designed to mount directly through a 1/2” KO in a single gang faceplate on pole/column, the SBO utilizes 100% Digital Passive Infrared (PIR) technology that is tuned for walking size while preventing false tripping from the environment.

Series Optics Hand Hole Orientation Program Color Photocell

Feature Voltage

MS

Motion Sensor

1 270° coverage - Single Sensor

00D0 (0V=0%)

WH WhiteY Yes UNV

09 D1 (1V=10%) BK Black N No 347

18 D3 (3V=30%)BZ Bronze

480

27 D5 (5V=50%)

DREV.

DWG SIZE

TYPE 27 (270Ā)

TYPE 18 (180Ā)

TYPE 09 (90Ā)

HAND HOLDLOCATION

TYPE 00 (0Ā)

TOP VIEW

SENSOR ANGULAR ORIENTATION FROM HAND HOLE 0ĀIN 90Ā INCREMENTS CLOCKWISE AROUND POLE (TYPE 00,09,18,27)

POLE DEPICTED IS GENERIC PLEASEREFERENCE CUSTOMER ORDER

FOR SPECIFIC POLE MODEL NUMBERTYPE 18 SHOWN

SCALE: 1:16

ADRAWN BY: FAH

DRW

JLJ

REVISIONSREV. ECN DESCRIPTION DATE BY APPR BY

01 XXXX CREATED FOR MARKETING 09/21/2016 FAH DRW

A 0017.17TO DETAIL MODIFICATION TOPOLES AND COLUMNS FOR

SENSOR MOUNTING ORIENTATIONLOGIC

07/12/2017 FAH DRW

12"305.00

NOMINALPOLE

HEIGHTMINUS 12"

NOMINALPOLE HEIGHT

HAND HOLELOCATIONA

4 X Ă .136 3.45 THRU8-32 UNC THRU

2 X Ă .188 4.76 THRU

2.00050.80

3.00076.20

1.00025.40

.50012.70

3.50088.90

3.25082.55

1.62541.28

1.75044.45

1.00025.40

DETAIL ASCALE 1 : 1

MATERIAL: SEE BOM

PRODUCT SERIES:

R

THIS DRAWING IS THE PROPERTY OF SELUX CORPORATION AND ISPROTECTED BY COPYRIGHT LAW. IT MAY ONLY BE COPIED ORREPRODUCED WITH PRIOR, WRITTEN AUTHORIZATION FOR THEPURPOSE OF MANUFACTURING AND/OR SUBMISSION FOR SELUXCORPORATION.

DWG. #: 6-48B323-00FINISH: PER SO

EXTERIOR SENSOR POLE MOD REFERENCE

T (845) 691-7723F (845) 691-6749

DATE: 9/21/2016

SHEET:1 OF 2

TOLERANCES UNLESS OTHERWISE NOTED:DECIMAL INCH:

.XX ā .02"

.XXX ā .010"

DECIMAL METRIC:

X.X ā .5X.XX ā .25

FRACTIONS: ā 1/32 [.79mm] ANGULAR: ā 1 1/2 Ā

5 LUMEN LANEP.O. BOX 1060HIGHLAND, NY 12528

CHECKED BY:

APPROVED BY:

ES01

A

DREV.

DWG SIZE

TYPE 27 (270Ā)

TYPE 18 (180Ā)

TYPE 09 (90Ā)

HAND HOLDLOCATION

TYPE 00 (0Ā)

TOP VIEW

SENSOR ANGULAR ORIENTATION FROM HAND HOLE 0ĀIN 90Ā INCREMENTS CLOCKWISE AROUND POLE (TYPE 00,09,18,27)

POLE DEPICTED IS GENERIC PLEASEREFERENCE CUSTOMER ORDER

FOR SPECIFIC POLE MODEL NUMBERTYPE 18 SHOWN

SCALE: 1:16

ADRAWN BY: FAH

DRW

JLJ

REVISIONSREV. ECN DESCRIPTION DATE BY APPR BY

01 XXXX CREATED FOR MARKETING 09/21/2016 FAH DRW

A 0017.17TO DETAIL MODIFICATION TOPOLES AND COLUMNS FOR

SENSOR MOUNTING ORIENTATIONLOGIC

07/12/2017 FAH DRW

12"305.00

NOMINALPOLE

HEIGHTMINUS 12"

NOMINALPOLE HEIGHT

HAND HOLELOCATIONA

4 X Ă .136 3.45 THRU8-32 UNC THRU

2 X Ă .188 4.76 THRU

2.00050.80

3.00076.20

1.00025.40

.50012.70

3.50088.90

3.25082.55

1.62541.28

1.75044.45

1.00025.40

DETAIL ASCALE 1 : 1

MATERIAL: SEE BOM

PRODUCT SERIES:

R

THIS DRAWING IS THE PROPERTY OF SELUX CORPORATION AND ISPROTECTED BY COPYRIGHT LAW. IT MAY ONLY BE COPIED ORREPRODUCED WITH PRIOR, WRITTEN AUTHORIZATION FOR THEPURPOSE OF MANUFACTURING AND/OR SUBMISSION FOR SELUXCORPORATION.

DWG. #: 6-48B323-00FINISH: PER SO

EXTERIOR SENSOR POLE MOD REFERENCE

T (845) 691-7723F (845) 691-6749

DATE: 9/21/2016

SHEET:1 OF 2

TOLERANCES UNLESS OTHERWISE NOTED:DECIMAL INCH:

.XX ā .02"

.XXX ā .010"

DECIMAL METRIC:

X.X ā .5X.XX ā .25

FRACTIONS: ā 1/32 [.79mm] ANGULAR: ā 1 1/2 Ā

5 LUMEN LANEP.O. BOX 1060HIGHLAND, NY 12528

CHECKED BY:

APPROVED BY:

ES01

A

General Pole Drawing For Example Only

NominalPoleHeight

12”(305mm)

HAND HOLDLOCATION 0 Ø (00)

90 Ø (09)

180 Ø (18)

270 Ø (27)

SENSOR ANGULAR ORIENTATION FROM HAND HOLE 0ØIN 90Ø INCREMENTS CLOCKWISE AROUND POLE (TYPE 00, 09,18, 27)

Sensor Angular Orientation from hand hole 0° in 90° increments clockwise around pole (Type 00, 09, 18, 27)

90° (09)

Hand Hole Location0° (00) 180° (18)

270° (27)

Page 4: Saturn Cutoff LED [SACL] selux Cutoff LED-- - - - ... driver for DMY option is Philips Xitanium Driver. 6. ... POLES AND COLUMNS FOR SENSOR MOUNTING ORIENTATION

Page 4 of 12 (Rev. 12/2017) SACL_SSv3.9

In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.

Selux Corporation © 2017, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us

DREV.

DWG SIZE

TYPE 27 (270Ā)

TYPE 18 (180Ā)

TYPE 09 (90Ā)

HAND HOLDLOCATION

TYPE 00 (0Ā)

TOP VIEW

SENSOR ANGULAR ORIENTATION FROM HAND HOLE 0ĀIN 90Ā INCREMENTS CLOCKWISE AROUND POLE (TYPE 00,09,18,27)

POLE DEPICTED IS GENERIC PLEASEREFERENCE CUSTOMER ORDER

FOR SPECIFIC POLE MODEL NUMBERTYPE 18 SHOWN

SCALE: 1:16

ADRAWN BY: FAH

DRW

JLJ

REVISIONSREV. ECN DESCRIPTION DATE BY APPR BY

01 XXXX CREATED FOR MARKETING 09/21/2016 FAH DRW

A 0017.17TO DETAIL MODIFICATION TOPOLES AND COLUMNS FOR

SENSOR MOUNTING ORIENTATIONLOGIC

07/12/2017 FAH DRW

12"305.00

NOMINALPOLE

HEIGHTMINUS 12"

NOMINALPOLE HEIGHT

HAND HOLELOCATIONA

4 X Ă .136 3.45 THRU8-32 UNC THRU

2 X Ă .188 4.76 THRU

2.00050.80

3.00076.20

1.00025.40

.50012.70

3.50088.90

3.25082.55

1.62541.28

1.75044.45

1.00025.40

DETAIL ASCALE 1 : 1

MATERIAL: SEE BOM

PRODUCT SERIES:

R

THIS DRAWING IS THE PROPERTY OF SELUX CORPORATION AND ISPROTECTED BY COPYRIGHT LAW. IT MAY ONLY BE COPIED ORREPRODUCED WITH PRIOR, WRITTEN AUTHORIZATION FOR THEPURPOSE OF MANUFACTURING AND/OR SUBMISSION FOR SELUXCORPORATION.

DWG. #: 6-48B323-00FINISH: PER SO

EXTERIOR SENSOR POLE MOD REFERENCE

T (845) 691-7723F (845) 691-6749

DATE: 9/21/2016

SHEET:1 OF 2

TOLERANCES UNLESS OTHERWISE NOTED:DECIMAL INCH:

.XX ā .02"

.XXX ā .010"

DECIMAL METRIC:

X.X ā .5X.XX ā .25

FRACTIONS: ā 1/32 [.79mm] ANGULAR: ā 1 1/2 Ā

5 LUMEN LANEP.O. BOX 1060HIGHLAND, NY 12528

CHECKED BY:

APPROVED BY:

ES01

A

General Pole Drawing For Example Only

• 100% Digital PIR Detection, excellent RF Immunity• 270° coverage pattern• Up to 30ft mounting• IP66 Rated for outdoor applications• Built-in 1kV surge protection• No minimum load requirements• Made for LED light source• Interchangeable hot and load wires - impossible to wire backwards• Adjustable time delays, max/min dim levels and ramp rates• Programming button accessible without opening sensor or removing gaskets• No field calibration or sensitivity adjustments required• Non-volatile setting memory• Convenient test mode• Suitable for Title 24 applications

LINECORD

BLKWHTBLKVIO

SBO SENSORGRY

GRN

WH

T

BLK

BLK

WH

TG

RN RED

ORG

BLK

WH

TG

RN

ORGRE

D

FIXT

URE

FEED

CO

RD

WEATHERPROOF WIRE CONNECTOR,600V 18-8GA

(SUPPLIED)

ATTACH CORD TO BACK OF SENSOR MOUNTING PLATEWITH 2 ZIP TIES (NOT SUPPLIED)

Motion Sensor Wiring

Motion Sensor Features

Saturn Cutoff LED

Page 5: Saturn Cutoff LED [SACL] selux Cutoff LED-- - - - ... driver for DMY option is Philips Xitanium Driver. 6. ... POLES AND COLUMNS FOR SENSOR MOUNTING ORIENTATION

Page 5 of 12 (Rev. 12/2017) SACL_SSv3.9

In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.

Selux Corporation © 2017, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us

Saturn Cutoff LED

Mounting

Single (1) Die-cast aluminum fitter base secured to pole with three stainless steel, Allen head set screws.

Single Arm Mount (1A) Die-cast aluminum single luminaire mounting arm secured to pole with four stainless steel, Allen head set screws. Outer slip fitter for 31/2” O.D. tenon.

Double (2) Die-cast aluminum double luminaire mounting arm secured to pole with four stainless steel, Allen head set screws. Outer slip fitter for 31/2” O.D. tenon.

Wall (W) Die-cast aluminum double round wall mount arm. Se-cured to wall with 1/4” diameter threaded fasteners (by others).

28 3/8” (720mm)

25” (635mm)

Pole Height (12’ shown)

3 1/2” (90mm)

36” (915mm)

21 7/8” (555mm)

72” (1830mm)

43 3/4” (1110mm)

36” (915mm)

32” (813mm)

21 7/8” (555mm)

Wall Arm Mounting Detail (Conduit and mounting hardware by others).

4 15/16” (121mm)

5 15/16” (151mm)

2 9/16” (65mm)

9 1/4” (235mm)

EPA = 1.3ft2 (0.12m2)

Weight = 39lbs. (17.7kg)

EPA = 2.3ft2 (0.21m2)

Weight = 53lbs. (24.0kg)

EPA = 4.2ft2 (0.39m2)

Weight = 176lbs. (79.8kg)

EPA = 2.1ft2 (0.20m2)

Weight = 50lbs. (22.7kg)

Page 6: Saturn Cutoff LED [SACL] selux Cutoff LED-- - - - ... driver for DMY option is Philips Xitanium Driver. 6. ... POLES AND COLUMNS FOR SENSOR MOUNTING ORIENTATION

Page 6 of 12 (Rev. 12/2017) SACL_SSv3.9

In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.

Selux Corporation © 2017, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us

Saturn Cutoff LED

Base Cover InformationRefer to pole specification sheets for construction details, anchorage information and additional options.

Standard Base Cover (BC5) Supplied with A35 and S35 Two-piece cast aluminum

Standard Base Cover (BC6) Supplied with S635 One-piece cast aluminum

Optional Base Cover (BC1) For A35 and S35 only One-piece cast aluminum

3 1/2” (89mm)

Ø12 7/16” (316mm)

5 1/4” (134mm)

65/8” (168mm)

Ø153/4” (400mm)

45/8” (118mm)

21 5/8” (550mm)

31/2” (89mm)

Ø12 5/8” (320mm)

Pole Series Bolt Circle

EPA InformationHeight Finish Options

70mph 80mph 90mph 100mph 110mph

S635 3 1/2” Diameter Stepped Steel Pole Ø9” 57.6 44.3 34.6 27.5 22.8

8 8ft.

WH White

BK Black

BZ Bronze

SV Silver

SP Specify Premium Color

BC1 Decorative Cast Aluminum Base Cover (for A35 & S35 poles only)

REC GFCI Receptacle with weatherproof cover1

(120V only)

REC2 GFCI Receptacle with weatherproof lockable cover1

(120V only)

MS Motion Sensor w/ Optional Photocell

(Meets Title 24 Requirements)

A35 3 1/2” Diameter Straight Aluminum Pole Ø7 3/4” 16.1 12.2 9.4 7.3 5.9

S35 3 1/2” Diameter Straight Steel Pole Ø7 3/4” 14.8 11.3 8.6 6.7 5.4

S635 3 1/2” Diameter Stepped Steel Pole Ø9” 45.6 35.0 27.3 21.6 17.8

10 10 ft.A35 3 1/2” Diameter Straight Aluminum Pole Ø7 3/4” 12.4 9.3 7.1 5.4 4.3

S35 3 1/2” Diameter Straight Steel Pole Ø7 3/4” 11.4 8.6 6.5 4.9 3.9

S635 3 1/2” Diameter Stepped Steel Pole Ø9” 37.6 28.7 22.3 17.5 14.4

12 12 ft.A35 3 1/2” Diameter Straight Aluminum Pole Ø7 3/4” 9.9 7.3 5.4 4.0 3.1

S35 3 1/2” Diameter Straight Steel Pole Ø7 3/4” 9.1 6.7 4.9 3.6 2.8

S635 3 1/2” Diameter Stepped Steel Pole Ø9” 31.7 24.2 18.6 14.6 11.9

14 14 ft.A35 3 1/2” Diameter Straight Aluminum Pole Ø7 3/4” 8.0 5.8 4.2 3.0 2.2

S35 3 1/2” Diameter Straight Steel Pole Ø7 3/4” 7.3 5.3 3.8 2.7 1.9

S635 3 1/2” Diameter Stepped Steel Pole Ø9” 21.7 15.8 12.3 9.6 7.6

16 16 ft.A35 3 1/2” Diameter Straight Aluminum Pole Ø7 3/4” 4.9 3.2 2.2 1.4 N/A

S35 3 1/2” Diameter Straight Steel Pole Ø7 3/4” 4.4 2.8 1.9 N/A N/A

Pole Data Chart

Pole InformationRefer to pole specification sheets for construction details, anchor-age information and additional options.

Pole Height (8’ shown)

A35 & S35 Round Straight Aluminum

& Round Straight Steel Poles

S635 Round Stepped Steel Poles

24” (610mm)

24” (610mm)

44” (1118mm)

Shown with standard base covers.

Page 7: Saturn Cutoff LED [SACL] selux Cutoff LED-- - - - ... driver for DMY option is Philips Xitanium Driver. 6. ... POLES AND COLUMNS FOR SENSOR MOUNTING ORIENTATION

Page 7 of 12 (Rev. 12/2017) SACL_SSv3.9

In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.

Selux Corporation © 2017, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us

Saturn Cutoff LEDSaturn Cutoff LED

Bolt Circle for A35 & S35 Use caution when setting anchor bolts. Bolts must be vertically straight and centered on dimensions shown

A35/S35 POLE ONLY

Hand Hold Location

7 3/4” (197mm)

07 3/4” (197mm) Bolt Circle

03” (76mm) Conduit Opening

Note: Adequate drainage must be provided in concrete foundation.

Anchor Bolt Detail for A35 & S35

3 1/4” (83mm)

3/4 x 17” Galvanized Anchor Bolts

3/4 -10 Galvanized Heavy Hex Nut

3/4” (19mm) ID Galvanized Flat Washers

Concrete footing designed and supplied by others

1/2” (13mm) for leveling

3/4 - 10 Galvanized Heavy Hex Leveling Nut

Bolt Circle for S635Use caution when setting anchor bolts. Bolts must be vertically straight and centered on dimensions shown.

S635 POLE ONLY

Hand Hold Location

8 1/2” (216mm)

09” (229mm) Bolt Circle

06 3/8” (162mm) Conduit Opening

Note: Adequate drainage must be provided in concrete foundation.

Anchor Bolt Detail for S635

Base Cover

3/4 x 17” Galvanized Anchor Bolts

2 3/4” (70mm)

1/4” (6mm) for leveling

3/4 - 10 Galvanized Heavy Hex Leveling Nut

3/4 -10 Galvanized Heavy Hex Nut

3/4” (19mm) ID Galvanized Flat Washers

Concrete footing designed and supplied by others

Page 8: Saturn Cutoff LED [SACL] selux Cutoff LED-- - - - ... driver for DMY option is Philips Xitanium Driver. 6. ... POLES AND COLUMNS FOR SENSOR MOUNTING ORIENTATION

Page 8 of 12 (Rev. 12/2017) SACL_SSv3.9

In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.

Selux Corporation © 2017, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us

Saturn Cutoff LED

Standard Single Wiring & Dynadim (DMY)

Wiring

0-10V Dimming Option (DM) Wiring LG4700 and LG4105, 120-277V. (347V and 480V available with step-down transformer.)

347/480 V

L1

N

BLACK

WHITE

GREEN

FROMLINECORD

SURGEPROTECTOR

LIGHTENGINE

L1

N

BLACK

WHITE

GREEN

RED

FROMLINECORD

SURGEPROTECTOR

LIGHTENGINE

L2RELAY

120/240/277V. WHEN RED IS ENERGIZED, LIGHT OUTPUT WILL BE AT "LO" LEVEL.SPECIFY THE "LO" OUTPUT LEVEL BY SELECTING FROM THE TABLE BELOW.

FOR OTHER PERCENTAGE OUTPUT LEVELS, CONSULT FACTORY.

HI-LO SWITCHING OPTION (HLxx) WIRING

Hi-Lo Switching Option (HL) Wiring LG4700 and LG4105, 120V, 240V, 277V. When red is energized, light output will be at “Lo” level. Specify low level by using one of the 3 levels listed below (i.e. HL70, HL50 and HL33). For other combinations, consult factory.

Standard HL levels LG4105 LG4700HL70 = low output 70% X XHL50 = low output 50% X XHL33 = low output 33% X X

L1

N

BLACK

WHITE

GREEN

Dim(+)

RED

ORANGEDim(-)

FROMLINECORD

SURGEPROTECTOR

LIGHTENGINE

100% LIGHT OUTPUT AT 10V, DOWN TO 10% LIGHT OUTPUT AT 0V.

0-10V DIMMING WIRING FOR 120-270V

L1

N

BLACK

WHITE

GREEN

FROMLINECORD

SURGEPROTECTOR

AUTOTRANSFORMER

LIGHTENGINE

STANDARD WIRING FOR 347/4800V WITH NO ADDITIONAL OPTIONS

STANDARD WIRING FOR 347/480V

Page 9: Saturn Cutoff LED [SACL] selux Cutoff LED-- - - - ... driver for DMY option is Philips Xitanium Driver. 6. ... POLES AND COLUMNS FOR SENSOR MOUNTING ORIENTATION

Page 9 of 12 (Rev. 12/2017) SACL_SSv3.9

In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.

Selux Corporation © 2017, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us

Saturn Cutoff LED

Optional Accessories

Photo Cell Tenon (PCT) - Button type photocell mounted in cast aluminum pole top tenon. Tenon has integral cast visor to prevent false start/stop cycle and can be oriented for optimum performance. Refer to luminaire spec sheet to determine if this option is applicable.

8 5/8” (219mm)

15 5/8” (397mm)

9/16” (14mm)

Dynadim (DMY) - Please refer to the Dynadim Option Form (includes a link to the Philips® Design-In Guide) on the Selux Saturn Cutoff LED webpage under Additional Downloads.

GFCI Receptacle (REC) - 120V 15A GFCI duplex receptacle with cast base bolted to pole and gasketed, provided with weather-proof, self-closing cover; located 36” (915mm) from base of pole, inline with handhole. Receptacle is intended only for portable tools or other portable equipment to be connected to outlet only when at-tended by operating personnel (120V only).

AREV.

DWG SIZE

SCALE: 1:1

DRAWN BY:

REVISIONSREV. ECN DESCRIPTION DATE BY APPR BY

2 ¾”[70mm]

4 ½"[114mm]

COVER SHOWNIN THE

CLOSED POSITION

(REC) GFCI RECEPTACLE DETAIL (120V)

5/8"15mm

POLE (GENERIC VIEW)

5/8"15mm

REF.

3 9/16"91mm

6 11/16"170mm

COVER SHOWNIN THE

CLOSED POSITION

(REC2) PADLOCKABLE IN-USE GFCI RECEPTACLE DETAIL (120V)

POLE (GENERIC VIEW)

2 1/4"58mm

REF.

MATERIAL:

PRODUCT SERIES:

R

THIS DRAWING IS THE PROPERTY OF SELUX CORPORATION AND ISPROTECTED BY COPYRIGHT LAW. IT MAY ONLY BE COPIED ORREPRODUCED WITH PRIOR, WRITTEN AUTHORIZATION FOR THEPURPOSE OF MANUFACTURING AND/OR SUBMISSION FOR SELUXCORPORATION.

DWG. #: A35-xx-REC2FINISH:

T (845) 691-7723F (845) 691-6749

TOLERANCES UNLESS OTHERWISE NOTED:DECIMAL INCH:

.XX ā .02"

.XXX ā .010"FRACTIONS: ā 1/32 [.79mm] ANGULAR: ā 1 1/2 Ā

DATE: 10/4/2017

SHEET:1 OF 1

DECIMAL METRIC:

X.X ā .5X.XX ā .25

5 LUMEN LANEP.O. BOX 1060HIGHLAND, NY 12528

CHECKED BY:

APPROVED BY:

5/8” (15mm)

2 3/4” (70mm)

4 1/2” (114mm)

Pole (Generic View)

No Uplight Finish (DS) - In order to achieve BUG U0 rating, the hood support and the driver cover are painted matte black to avoid uplight.

Single Fusing (FS) - Single inline fuse holder, shipped sepa-rately for infield installation behind hand hole (by others). Available up to 277V.

GFCI Receptacle (REC2) - 120V 15A GFCI duplex receptacle with cast base bolted to pole and gasketed, provided with weather-proof, self-closing, lockable cover; located 36” (915mm) from base of pole, inline with handhole. Receptacle is intended only for portable tools or other portable equipment to be connected to outlet only when attended by operating personnel (120V only).

AREV.

DWG SIZE

SCALE: 1:1

DRAWN BY:

REVISIONSREV. ECN DESCRIPTION DATE BY APPR BY

2 ¾”[70mm]

4 ½"[114mm]

COVER SHOWNIN THE

CLOSED POSITION

(REC) GFCI RECEPTACLE DETAIL (120V)

5/8"15mm

POLE (GENERIC VIEW)

5/8"15mm

REF.

3 9/16"91mm

6 11/16"170mm

COVER SHOWNIN THE

CLOSED POSITION

(REC2) PADLOCKABLE IN-USE GFCI RECEPTACLE DETAIL (120V)

POLE (GENERIC VIEW)

2 1/4"58mm

REF.

MATERIAL:

PRODUCT SERIES:

R

THIS DRAWING IS THE PROPERTY OF SELUX CORPORATION AND ISPROTECTED BY COPYRIGHT LAW. IT MAY ONLY BE COPIED ORREPRODUCED WITH PRIOR, WRITTEN AUTHORIZATION FOR THEPURPOSE OF MANUFACTURING AND/OR SUBMISSION FOR SELUXCORPORATION.

DWG. #: A35-xx-REC2FINISH:

T (845) 691-7723F (845) 691-6749

TOLERANCES UNLESS OTHERWISE NOTED:DECIMAL INCH:

.XX ā .02"

.XXX ā .010"FRACTIONS: ā 1/32 [.79mm] ANGULAR: ā 1 1/2 Ā

DATE: 10/4/2017

SHEET:1 OF 1

DECIMAL METRIC:

X.X ā .5X.XX ā .25

5 LUMEN LANEP.O. BOX 1060HIGHLAND, NY 12528

CHECKED BY:

APPROVED BY:

3 9/16” (91mm)

6 11/16” (170mm)

2 1/4” (58mm)

Pole (Generic View)

Cover shown in the closed position

Cover shown in the closed position

Page 10: Saturn Cutoff LED [SACL] selux Cutoff LED-- - - - ... driver for DMY option is Philips Xitanium Driver. 6. ... POLES AND COLUMNS FOR SENSOR MOUNTING ORIENTATION

Page 10 of 12 (Rev. 12/2017) SACL_SSv3.9

In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.

Selux Corporation © 2017, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us

Saturn Cutoff LED

Optional Accessories

House Side Shield

Side ViewFront View

6” (152mm)

6” (152mm)

Street Side

House Side

Page 11: Saturn Cutoff LED [SACL] selux Cutoff LED-- - - - ... driver for DMY option is Philips Xitanium Driver. 6. ... POLES AND COLUMNS FOR SENSOR MOUNTING ORIENTATION

Page 11 of 12 (Rev. 12/2017) SACL_SSv3.9

In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.

Selux Corporation © 2017, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us

Saturn Cutoff LED

R2 Optics / 103W LED / 5000K CCT

Saturn Cutoff LED

Photometry

Catalog #: SACL-R1-X-LG4105-50-120 Delivered Lumens: 7116Input Watts: 102.5W Efficacy: 69 lm/WCRI: >81Maximum candela of 5587 at 62.5° from vertical.IES classification - Type I Full-CutoffMounting Height = 16’ (4.9 m)B2-U0-G1Power Factor: 0.998Total Harmonic Distortion: 2.84%

Link to photometry (PDF) Link to photometry (IES)

R1 Optics / 102W LED / 5000K CCT

Conversion ChartValues based on 16’ (4.9 m) mounting height

Mounting Height 10’ (3.0 m)12’ (3.7 m)14’ (4.3 m)16’ (4.9 m)18’ (5.5 m)

Multiply1.271.161.071.000.84

1397

2794

4190

5587

1

Maximum Candela = 5587.226 Located At Horizontal Angle = 62.5, Vertical Angle = 35# 1 - Vertical Plane Through Horizontal Angles (62.5 - 242.5) (Through Max. Cd.)

1200

2400

3600

4799

1

Maximum Candela = 4799.417 Located At Horizontal Angle = 45, Vertical Angle = 47.5# 1 - Vertical Plane Through Horizontal Angles (45 - 225) (Through Max. Cd.)

012 2.253 3.75 45 675

4

32.75

21.75

1

0

1

2

3

House Side Street Side

Distance In Units Of Mounting Heigh tValues Based On 16 Foot Mounting Heigh t

.1

.2

.5

1

2

012 2.253 3.75 45 675

4

32.75

21.75

1

0

1

2

3

House Side Street Side

Distance In Units Of Mounting Heigh tValues Based On 16 Foot Mounting Heigh t

.1

.2

.5

1

2

Catalog #: SACL-R2-X-LG4105-50-120 Delivered Lumens: 7422 Input Watts: 103W Efficacy: 72 lm/WCRI: >81Maximum candela of 4799 at 47.5° from vertical.IES classification - Type II Full-Cutoff.Mounting Height = 16’ (4.9 m)B2-U0-G1Power Factor: 0.998Total Harmonic Distortion: 2.84%

Link to photometry (PDF) Link to photometry (IES)

LED Information Standard Power Electrical Specification (Type V Shown)

Color Temerature 5000K 4000K 3500K 3000K

Drive Current 1050 700 500 1050 700 500 1050 700 500 1050 700 500

Performance

Delivered Lumens (lm) 8053 5805 4318 7753 5589 4153 6946 5007 3724 7223 5207 3873

Wattage (W) 102 68 50 102 68 50 102 68 50 102 68 50

Efficacy (lm/W) 79 85 86 76 82 84 68 73 74 71 76 78

LED CCT Prorate TableValues based on Flux Binning

CCT 3000K3500K4000K5000K

Theoretical Multiplier1.000.9611.0731.115

Page 12: Saturn Cutoff LED [SACL] selux Cutoff LED-- - - - ... driver for DMY option is Philips Xitanium Driver. 6. ... POLES AND COLUMNS FOR SENSOR MOUNTING ORIENTATION

Page 12 of 12 (Rev. 12/2017) SACL_SSv3.9

In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.

Selux Corporation © 2017, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us

R3 Optics / 65W LED / 5000K CCT

R5 Optics / 65W LED / 5000K CCT

927

1855

2782

3710

1

Maximum Candela = 3709.501 Located At Horizontal Angle = 60, Vertical Angle = 60# 1 - Vertical Plane Through Horizontal Angles (60 - 240) (Through Max. Cd.)

012 2.253 3.75 45 675

4

32.75

21.75

1

0

1

2

3

House Side Street Side

Distance In Units Of Mounting Heigh tValues Based On 16 Foot Mounting Heigh t

.1

.2

.5

1

2

751

1502

2253

3004

1

Maximum Candela = 3004.444 Located At Horizontal Angle = 135, Vertical Angle = 60# 1 - Vertical Plane Through Horizontal Angles (135 - 315) (Through Max. Cd.)

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINANCE

012 2.253 3.75 45 675

4

32.75

21.75

1

0

1

2

3

House Side Street Side

Distance In Units Of Mounting Heigh tValues Based On 16 Foot Mounting Heigh t

.1

.2

.5

1

2

Catalog #:SACL-R3-X-LG4105-50-120 Delivered Lumens: 7599 Input Watts: 102W Efficacy: 74 lm/WCRI: >81Maximum candela of 3709 at 60° from vertical.IES classification - Type III Full-Cutoff.Mounting Height = 16’ (4.9 m)B2-U0-G1Power Factor: 0.998Total Harmonic Distortion: 2.84%

Link to photometry (PDF) Link to photometry (IES)

Catalog #: SACL-R5-X-LG4105-50-120 Delivered Lumens: 103Input Watts: 67W Efficacy: 79 lm/WCRI: >81Maximum candela of 3004 at 60° from vertical.IES classification - Type VMounting Height = 16’ (4.9 m)B3-U0-G1Power Factor: 0.998Total Harmonic Distortion: 2.84%

Link to photometry (PDF) Link to photometry (IES)

Saturn Cutoff LEDSaturn Cutoff LED

Photometry