Report: 2650044-11 Project: 2650044 Client: Cree Inc. 6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134 Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948 www.csagroup.com Page 1 of 15 PHOTOMETRIC TESTING & EVALUATION TO IES LM-79-08 Sample Tested ARE-EDG-4M-XX-06-E-UL-XX-700-40K-XXXX (BXAL*406E-UD7) Prepared for: Jon Vollers Cree Inc. 4600 Silicon Drive Durham, NC 27703 USA Phone: 919-407-4077 Technical Report Number 2650044-11 July 31, 2013 Prepared by: Approved by: James E. Berkeley, Program Manager Wensheng Xu, Technical Advisor

Transcript of Sample Tested ARE-EDG-4M-XX-06-E-UL-XX-700-40K-XXXX …...IES Classification Semi-Cutoff, Type III...

Page 1: Sample Tested ARE-EDG-4M-XX-06-E-UL-XX-700-40K-XXXX …...IES Classification Semi-Cutoff, Type III –Short ‡Based upon IES file generated output –Total Lumens may differ from

Report: 2650044-11

Project: 2650044

Client: Cree Inc.

6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134

Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948

www.csagroup.com Page 1 of 15

PHOTOMETRIC TESTING & EVALUATION TO IES LM-79-08

Sample Tested

ARE-EDG-4M-XX-06-E-UL-XX-700-40K-XXXX (BXAL*406E-UD7)

Prepared for:

Jon Vollers

Cree Inc.

4600 Silicon Drive

Durham, NC 27703

USA

Phone: 919-407-4077

Technical Report Number

2650044-11

July 31, 2013

Prepared by: Approved by:

James E. Berkeley, Program Manager Wensheng Xu, Technical Advisor

Page 2: Sample Tested ARE-EDG-4M-XX-06-E-UL-XX-700-40K-XXXX …...IES Classification Semi-Cutoff, Type III –Short ‡Based upon IES file generated output –Total Lumens may differ from

Report: 2650044-11

Project: 2650044

Client: Cree Inc.

6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134

Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948

www.csagroup.com Page 2 of 15

Program Description

Photometric and electrical testing of a “ARE-EDG-4M-XX-06-E-UL-XX-700-40K-XXXX (BXAL*406E-

UD7) ” Roadway Style Luminaire to IES LM-79-08.

Executive Summary

Sample Tested = Edge Area Square Luminaire – Type IV Medium Optics

SKU: ARE-EDG-4M-XX-06-E-UL-XX-700-40K-XXXX (BXAL*406E-UD7)

Serial Number: 6922040213041043

LED Driver: Philips LED-INTA-0700C-210D0

Original Goniophotometer Data taken April 2013

Luminous Efficacy*

(Lumens/Watt)

Luminous Flux*

(Lumens)

Input Power*

(Watts) Power Factor*

85.07 11180 131.42 0.995

CCT (K)* CRI* Stabilization Time

(Light & Power)

3914.0 71.9 45 minutes

* The above results are recorded / derived from measurements made using an Integrating Sphere

Roadway Summary‡ - Utilization

Downward Utilization Percentage of Luminaire

Street Side Lumens 7,443.60 65.50%

House Side Lumens 3,921.80 34.50%

Total 11,365.40 100%

Upward Utilization 0 Lumens / 0.0% (no up-light)

IES Classification Semi-Cutoff, Type III –Short ‡ Based upon IES file generated output – Total Lumens may differ from Integrating Sphere results.

Gonio-Photometric calculations based upon a mount height of 30ft.

Page 3: Sample Tested ARE-EDG-4M-XX-06-E-UL-XX-700-40K-XXXX …...IES Classification Semi-Cutoff, Type III –Short ‡Based upon IES file generated output –Total Lumens may differ from

Report: 2650044-11

Project: 2650044

Client: Cree Inc.

6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134

Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948

www.csagroup.com Page 3 of 15

TABLE OF CONTENTS

Test Results ............................................................................................................................................................. 5

Spectral Flux ........................................................................................................................................................... 6

Chromaticity Diagram ............................................................................................................................................ 7

Flux Distribution – Zonal Lumen Summary ........................................................................................................... 8

Illuminance Plots .................................................................................................................................................... 9

Candela Plots ........................................................................................................................................................ 10

Candela Tabulation ............................................................................................................................................... 11

BUG Rating Analysis ........................................................................................................................................... 12

Photometric Testing Information .......................................................................................................................... 13

Equipment List: ..................................................................................................................................................... 15

Page 4: Sample Tested ARE-EDG-4M-XX-06-E-UL-XX-700-40K-XXXX …...IES Classification Semi-Cutoff, Type III –Short ‡Based upon IES file generated output –Total Lumens may differ from

Report: 2650044-11

Project: 2650044

Client: Cree Inc.

6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134

Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948

www.csagroup.com Page 4 of 15

Sample

The following sample was submitted for evaluation:

Cree Inc.: ARE-EDG-4M-XX-06-E-UL-XX-700-40K-XXXX (BXAL*406E-UD7)

ARE-EDG-4M-XX-06-E-UL-XX-700-40K-XXXX (BXAL*406E-UD7)

Page 5: Sample Tested ARE-EDG-4M-XX-06-E-UL-XX-700-40K-XXXX …...IES Classification Semi-Cutoff, Type III –Short ‡Based upon IES file generated output –Total Lumens may differ from

Report: 2650044-11

Project: 2650044

Client: Cree Inc.

6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134

Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948

www.csagroup.com Page 5 of 15

Test Results –

The following results were measured after stabilization of the sample in the Integrating Sphere (unless

otherwise stated). Stability is reached when the variation of 3 readings of light output and electrical power,

taken 15 minutes apart, is less than 0.50% (in accordance with IES LM-79-08).

Key Photometric Results Sample Reference

ARE-EDG-4M-XX-06-E-UL-XX-700-40K-XXXX (BXAL*406E-UD7)

Integrating Sphere Goniophotometer

Luminous Efficacy (Lumens/Watt) 85.07 86.29

Total Luminous Flux (Lumens) 11180 11366.7

Total Radiant Flux (Watts) 33.91

Correlated Color Temperature (CCT) 3914.0

Color Rendering Index (CRI) (Ra) 71.9

R1 thru R7 Value 69.9 76.1 81.4 73.3 69.3 67.2 80.6

R8 thru R14 Value 57 -20.3 43.6 70.2 43.7 70 89.1

Chromaticity (Chroma x / Chroma y) 0.3860 / 0.3854

Chromaticity (Chroma u / Chroma v) 0.2253 / 0.3374

Chromaticity (Chroma u’ / Chroma v’) 0.2253 / 0.5061

Duv Value 0.00239

Stabilization Time (Light and Power) Approx. 45 minutes

Total Run Time – Integrating Sphere 49 minutes

Total Run Time – Goniophotometer 118 minutes

IES Classification Semi-Cutoff, Type III – Short

Scotopic/Photopic ratio Φ(v')/Φ(v) 1.456

Electrical Input Results: Sample Reference

ARE-EDG-4M-XX-06-E-UL-XX-700-40K-XXXX (BXAL*406E-UD7)

Integrating Sphere Goniophotometer

Input Power (Watts) 131.42 (129.15) 131.73

Input Voltage (Volts AC) 120.0 (277.0) 120.0

Input Current (Amps) 1.10 (0.49) 1.10

Input Frequency (Hertz) 60.0 60.0

Power Factor 0.995 (0.954) 0.995

Total Harmonic Distortion (%THD V/A) 0.12 / 3.83 (0.10 / 8.76)

Additional Information Sample Reference

ARE-EDG-4M-XX-06-E-UL-XX-700-40K-XXXX (BXAL*406E-UD7)

Ambient Temperature 24.9 °C

Integrating Sphere Detector CDS 600 Spectroradiometer

Absorption Correction used? Yes

Page 6: Sample Tested ARE-EDG-4M-XX-06-E-UL-XX-700-40K-XXXX …...IES Classification Semi-Cutoff, Type III –Short ‡Based upon IES file generated output –Total Lumens may differ from

Report: 2650044-11

Project: 2650044

Client: Cree Inc.

6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134

Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948

www.csagroup.com Page 6 of 15

Spectral Flux

The following graph shows the spectral response curve of the radiant flux for the sample:

Spectral response of the Radiant Flux

(350nm to 850nm – calibrated range of the Spectroradiometer).

Page 7: Sample Tested ARE-EDG-4M-XX-06-E-UL-XX-700-40K-XXXX …...IES Classification Semi-Cutoff, Type III –Short ‡Based upon IES file generated output –Total Lumens may differ from

Report: 2650044-11

Project: 2650044

Client: Cree Inc.

6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134

Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948

www.csagroup.com Page 7 of 15

Chromaticity Diagram

The following image shows the chromaticity diagram for the sample:

Tristimulus values (from page 5):

x / y = 0.3860 / 0.3854

The locations on the diagram of the tristimulus coordinates are indicated by the blue diamond.

Page 8: Sample Tested ARE-EDG-4M-XX-06-E-UL-XX-700-40K-XXXX …...IES Classification Semi-Cutoff, Type III –Short ‡Based upon IES file generated output –Total Lumens may differ from

Report: 2650044-11

Project: 2650044

Client: Cree Inc.

6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134

Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948

www.csagroup.com Page 8 of 15

Test Results – Flux Distribution – Zonal Lumen Summary

The following table depicts the zonal lumen distribution for the sample:

Zone Lumens % Total 0 - 10 101.4 0.90%

10 - 20 361.1 3.20%

20 - 30 784.8 6.90%

30 - 40 1,324.60 11.70%

40 - 50 1,969.90 17.30%

50 - 60 2,973.60 26.20%

60 - 70 2,571.00 22.60%

70 - 80 1,113.40 9.80%

80 - 90 166.8 1.50%

90-100 0 0%

100-110 0 0%

110-120 0 0%

120-130 0 0%

130-140 0 0%

140-150 0 0%

150-160 0 0%

160-170 0 0%

170-180 0 0%

Total 11366.7 Lumens 100%

Zonal Lumen Summary

Zone Lumens % Lamp / Luminaire 0-60 7,515.50 66.10%

60-90 3,851.20 33.90%

0-90 11,366.70 100%

90-180 0 0%

0-180 11,366.70 100%

Page 9: Sample Tested ARE-EDG-4M-XX-06-E-UL-XX-700-40K-XXXX …...IES Classification Semi-Cutoff, Type III –Short ‡Based upon IES file generated output –Total Lumens may differ from

Report: 2650044-11

Project: 2650044

Client: Cree Inc.

6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134

Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948

www.csagroup.com Page 9 of 15

Test Results – Illuminance Plots

The following images depict the illuminance characteristics of the luminaire.

Beam Angle Field Angle

Illuminance Plot (Footcandles) Roadway Utilization Curve

Page 10: Sample Tested ARE-EDG-4M-XX-06-E-UL-XX-700-40K-XXXX …...IES Classification Semi-Cutoff, Type III –Short ‡Based upon IES file generated output –Total Lumens may differ from

Report: 2650044-11

Project: 2650044

Client: Cree Inc.

6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134

Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948

www.csagroup.com Page 10 of 15

Test Results – Candela Plots

The following images depict the luminous intensity distribution characteristics of the luminaire.

Isocandela Plot Polar Candela Distribution

Page 11: Sample Tested ARE-EDG-4M-XX-06-E-UL-XX-700-40K-XXXX …...IES Classification Semi-Cutoff, Type III –Short ‡Based upon IES file generated output –Total Lumens may differ from

Report: 2650044-11

Project: 2650044

Client: Cree Inc.

6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134

Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948

www.csagroup.com Page 11 of 15

Test Results – Candela Tabulation

The following table provides the tabulated Candela measurements: Candela Table - Type C

0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 360

0 1017 1017 1017 1017 1017 1017 1017 1017 1017 1017 1017 1017 1017 1017 1017 1017 1017 1017 1017 1017 1017 1017 1017 1017 1017 1017 1017 1017 1017 1017 1017 1017 1017 1017 1017 1017 1017

2.5 1055 1057 1059 1055 1052 1045 1038 1030 1024 1011 1010 1003 998 996 993 989 988 983 988 983 988 989 993 996 998 1003 1010 1011 1024 1030 1038 1045 1052 1055 1059 1057 1055

5 1094 1093 1094 1089 1090 1074 1063 1050 1039 1019 1013 1002 994 991 989 987 990 986 986 986 990 987 989 991 994 1002 1013 1019 1039 1050 1063 1074 1090 1089 1094 1093 1094

7.5 1133 1137 1140 1138 1139 1118 1100 1082 1065 1041 1031 1019 1012 1010 1011 1012 1018 1018 1015 1018 1018 1012 1011 1010 1012 1019 1031 1041 1065 1082 1100 1118 1139 1138 1140 1137 1133

10 1196 1197 1210 1213 1204 1182 1155 1130 1105 1076 1062 1051 1044 1047 1052 1061 1074 1078 1070 1078 1074 1061 1052 1047 1044 1051 1062 1076 1105 1130 1155 1182 1204 1213 1210 1197 1196

12.5 1258 1262 1284 1293 1287 1254 1225 1191 1161 1120 1100 1084 1079 1088 1104 1125 1149 1160 1153 1160 1149 1125 1104 1088 1079 1084 1100 1120 1161 1191 1225 1254 1287 1293 1284 1262 1258

15 1330 1336 1367 1383 1379 1349 1314 1274 1235 1176 1140 1115 1107 1125 1157 1196 1231 1250 1243 1250 1231 1196 1157 1125 1107 1115 1140 1176 1235 1274 1314 1349 1379 1383 1367 1336 1330

17.5 1412 1421 1461 1488 1490 1467 1449 1409 1350 1265 1201 1150 1133 1164 1215 1264 1309 1334 1332 1334 1309 1264 1215 1164 1133 1150 1201 1265 1350 1409 1449 1467 1490 1488 1461 1421 1412

20 1520 1534 1581 1607 1624 1638 1654 1587 1485 1360 1268 1200 1192 1222 1272 1322 1372 1408 1407 1408 1372 1322 1272 1222 1192 1200 1268 1360 1485 1587 1654 1638 1624 1607 1581 1534 1520

22.5 1721 1710 1736 1749 1786 1867 1888 1748 1594 1438 1318 1271 1272 1286 1319 1379 1448 1498 1501 1498 1448 1379 1319 1286 1272 1271 1318 1438 1594 1748 1888 1867 1786 1749 1736 1710 1721

25 1945 1935 1935 1914 1984 2123 2112 1873 1675 1491 1371 1342 1336 1343 1379 1456 1533 1591 1597 1591 1533 1456 1379 1343 1336 1342 1371 1491 1675 1873 2112 2123 1984 1914 1935 1935 1945

27.5 2262 2198 2134 2104 2216 2378 2301 1971 1738 1531 1430 1392 1387 1420 1465 1542 1617 1674 1685 1674 1617 1542 1465 1420 1387 1392 1430 1531 1738 1971 2301 2378 2216 2104 2134 2198 2262

30 2767 2589 2337 2289 2463 2627 2459 2054 1785 1565 1467 1438 1454 1507 1555 1620 1691 1753 1767 1753 1691 1620 1555 1507 1454 1438 1467 1565 1785 2054 2459 2627 2463 2289 2337 2589 2767

32.5 2969 2780 2474 2441 2688 2863 2598 2125 1817 1591 1507 1511 1536 1589 1632 1682 1752 1818 1832 1818 1752 1682 1632 1589 1536 1511 1507 1591 1817 2125 2598 2863 2688 2441 2474 2780 2969

35 2859 2750 2533 2557 2873 3055 2723 2180 1839 1623 1574 1588 1621 1660 1688 1727 1790 1856 1872 1856 1790 1727 1688 1660 1621 1588 1574 1623 1839 2180 2723 3055 2873 2557 2533 2750 2859

37.5 2652 2628 2554 2623 3031 3234 2850 2239 1875 1706 1671 1686 1713 1723 1726 1750 1806 1876 1896 1876 1806 1750 1726 1723 1713 1686 1671 1706 1875 2239 2850 3234 3031 2623 2554 2628 2652

40 2589 2596 2550 2654 3163 3412 3018 2366 1992 1855 1821 1816 1815 1782 1746 1757 1814 1896 1917 1896 1814 1757 1746 1782 1815 1816 1821 1855 1992 2366 3018 3412 3163 2654 2550 2596 2589

42.5 2500 2558 2550 2693 3329 3636 3238 2491 2174 2036 1973 1923 1876 1808 1748 1761 1840 1947 1975 1947 1840 1761 1748 1808 1876 1923 1973 2036 2174 2491 3238 3636 3329 2693 2550 2558 2500

45 2380 2453 2507 2876 3768 4012 3497 2695 2435 2300 2190 2073 1923 1814 1742 1774 1899 2040 2073 2040 1899 1774 1742 1814 1923 2073 2190 2300 2435 2695 3497 4012 3768 2876 2507 2453 2380

47.5 2725 2567 2636 3152 4242 4378 3825 3142 2954 2792 2605 2343 2061 1824 1735 1811 1967 2088 2138 2088 1967 1811 1735 1824 2061 2343 2605 2792 2954 3142 3825 4378 4242 3152 2636 2567 2725

50 2879 2896 2871 3529 4787 4910 4415 3878 3773 3556 3243 2818 2344 1932 1760 1852 1958 2048 2103 2048 1958 1852 1760 1932 2344 2818 3243 3556 3773 3878 4415 4910 4787 3529 2871 2896 2879

52.5 2838 2827 2755 3675 5175 5382 5028 4585 4398 4139 3768 3309 2754 2136 1850 1821 1870 1956 2022 1956 1870 1821 1850 2136 2754 3309 3768 4139 4398 4585 5028 5382 5175 3675 2755 2827 2838

55 2791 2780 2696 3659 5379 5785 5431 4926 4695 4307 3944 3519 3041 2326 1839 1695 1741 1828 1903 1828 1741 1695 1839 2326 3041 3519 3944 4307 4695 4926 5431 5785 5379 3659 2696 2780 2791

57.5 2722 2696 2654 3531 5611 6070 5394 4835 4469 3995 3656 3369 3095 2340 1700 1533 1579 1655 1727 1655 1579 1533 1700 2340 3095 3369 3656 3995 4469 4835 5394 6070 5611 3531 2654 2696 2722

60 2997 2910 2945 3728 6090 6037 4992 4385 3899 3454 3199 3052 2845 2141 1532 1350 1381 1415 1482 1415 1381 1350 1532 2141 2845 3052 3199 3454 3899 4385 4992 6037 6090 3728 2945 2910 2997

62.5 3395 3385 3479 4251 6507 5781 4446 3768 3244 2830 2599 2613 2403 1785 1328 1154 1135 1113 1152 1113 1135 1154 1328 1785 2403 2613 2599 2830 3244 3768 4446 5781 6507 4251 3479 3385 3395

65 3376 3497 3615 4471 6380 5492 3813 3070 2544 2199 1962 1878 1796 1405 1092 938 879 856 892 856 879 938 1092 1405 1796 1878 1962 2199 2544 3070 3813 5492 6380 4471 3615 3497 3376

67.5 3027 3214 3362 4230 5743 4955 3038 2325 1870 1615 1474 1330 1205 979 837 727 703 737 771 737 703 727 837 979 1205 1330 1474 1615 1870 2325 3038 4955 5743 4230 3362 3214 3027

70 2624 2762 2887 3628 4905 4075 2266 1665 1305 1123 1065 956 806 593 566 552 611 673 709 673 611 552 566 593 806 956 1065 1123 1305 1665 2266 4075 4905 3628 2887 2762 2624

72.5 2218 2281 2325 2821 3992 3068 1614 1131 836 718 719 679 544 379 410 468 561 627 663 627 561 468 410 379 544 679 719 718 836 1131 1614 3068 3992 2821 2325 2281 2218

75 1755 1763 1696 1993 3168 2222 1103 712 485 422 439 452 387 304 383 456 529 585 615 585 529 456 383 304 387 452 439 422 485 712 1103 2222 3168 1993 1696 1763 1755

77.5 1255 1234 1110 1305 2419 1535 709 413 252 214 250 276 266 273 381 447 497 534 559 534 497 447 381 273 266 276 250 214 252 413 709 1535 2419 1305 1110 1234 1255

80 827 792 711 817 1770 1007 400 187 113 92 118 136 151 181 245 322 350 366 409 366 350 322 245 181 151 136 118 92 113 187 400 1007 1770 817 711 792 827

82.5 507 492 456 512 1123 518 192 85 54 41 54 72 67 62 71 121 96 82 109 82 96 121 71 62 67 72 54 41 54 85 192 518 1123 512 456 492 507

85 274 275 268 265 462 220 63 24 18 12 17 29 26 19 20 24 24 26 29 26 24 24 20 19 26 29 17 12 18 24 63 220 462 265 268 275 274

87.5 79 116 81 66 74 35 10 6 5 4 5 10 9 8 8 9 10 11 14 11 10 9 8 8 9 10 5 4 5 6 10 35 74 66 81 116 79

90 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

92.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

95 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

97.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

100 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

102.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

105 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

107.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

110 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

112.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

115 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

117.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

120 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

122.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

125 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

127.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

130 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

132.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

135 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

137.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

140 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

142.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

145 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

147.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

150 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

152.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

155 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

157.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

160 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

162.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

165 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

167.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

170 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

172.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

175 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

177.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

180 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

Page 12: Sample Tested ARE-EDG-4M-XX-06-E-UL-XX-700-40K-XXXX …...IES Classification Semi-Cutoff, Type III –Short ‡Based upon IES file generated output –Total Lumens may differ from

Report: 2650044-11

Project: 2650044

Client: Cree Inc.

6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134

Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948

www.csagroup.com Page 12 of 15

BUG Rating Analysis

The following table shows the BUG rating classification:

Luminaire Classification System (LCS)

LCS Zone Lumens % of Luminaire FL 0 - 30 696.1 6.1

FM 30 - 60 3867.1 34

FH 60 - 80 2744.1 24.1

FVH 80 - 90 136 1.2

BL 0 - 30 550 4.8

BM 30 - 60 2399.3 21.1

BH 60 - 80 941.5 8.3

BVH 80 - 90 30.8 0.3

UL 90 - 100 0 0

UH 100 - 180 0 0

Total 11364.9 100

BUG RATING = B2-U0-G2

Page 13: Sample Tested ARE-EDG-4M-XX-06-E-UL-XX-700-40K-XXXX …...IES Classification Semi-Cutoff, Type III –Short ‡Based upon IES file generated output –Total Lumens may differ from

Report: 2650044-11

Project: 2650044

Client: Cree Inc.

6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134

Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948

www.csagroup.com Page 13 of 15

Continued…..

Photometric Testing Information

The sample was evaluated for photometric and electrical characteristics using an integrating sphere and a

goniophotometer, each located in purpose-built, temperature and humidity-controlled, draft free environments.

The integrating sphere is by Labsphere which exhibits a “4π geometry” configuration according to IES LM-79-

08 and is applicable for all types of LED products (directional and non-directional light projections). Its

spectroradiometer is an array-type detector manufactured and calibrated by Labsphere.

The integrating sphere uses self-absorption correction to eliminate errors due to mismatches between the

standard reference lamp and the test samples being measured. The auxiliary lamp used to perform this task is a

halogen type lamp powered by a calibrated Lamp Power Supply manufactured and calibrated by Labsphere.

Ambient temperature (for photometric analysis) is measured using a “J-Type” thermocouple located inside the

integrating sphere at the same height as the sample under test and not more than 1 meter in horizontal distance

away from the sample. The thermocouple is located behind the baffle of the photo detector in order to eliminate

any direct optical radiation from the sample under test.

Luminaire Stabilization.

The sample was placed inside the integrating sphere and powered by a regulated and conditioned Voltage

alternating current supply. The correlated color temperature, color rendering index, chromaticity coordinates

and electrical power measurements contained in this report are the numeric averages of the three readings upon

which stabilization is verified. The stabilization times shown on the results pages of this report denote the time

of the 1st measurement (of the 3 consecutive readings) since this is the minimum time that the sample is

assumed to have taken to reach stabilization.

The integrating sphere is calibrated using a quartzline halogen lamp with the following specifications:

Manufacturer: Sylvania

Model# 75Q/CL-28V

Voltage = 28.0 Volt

Wattage = 75.0 Watts

Calibration Current = 2.679 Amperes

Luminous Flux = 1538.8 Lumens

Calibration Date = 8-18-2005 (calibrated by Labsphere – NIST traceable).

Page 14: Sample Tested ARE-EDG-4M-XX-06-E-UL-XX-700-40K-XXXX …...IES Classification Semi-Cutoff, Type III –Short ‡Based upon IES file generated output –Total Lumens may differ from

Report: 2650044-11

Project: 2650044

Client: Cree Inc.

6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134

Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948

www.csagroup.com Page 14 of 15

Photometric Testing Information (continued)

The goniophotometer Mayer Engineering Type C is calibrated using a frosted tungsten filament FDS/DZE lamp

with the following specifications:

Manufacturer: GE

Part Number: DZE 88

Bulb Number: 114-A

Voltage: 16.59 Volts DC reference

Calibration Current: 4.810 Amperes

Luminous Intensity: 154.7 Candelas

Calibration Date: 7/12/12 (NIST traceable)

Manufacturer: GE

Part Number: DZE 88

Bulb Number: 114-B

Voltage: 16.61 Volts DC reference

Calibration Current: 4.819 Amperes

Luminous Intensity: 150.6 Candelas

Calibration Date: 7/12/12(NIST traceable)

Manufacturer: GE

Part Number: DZE 88

Bulb Number: 114-C

Voltage: 16.66 Volts DC reference

Calibration Current: 4.815 Amperes

Luminous Intensity: 155.4 Candelas

Calibration Date: 7/12/12 (NIST traceable)

A Yokogawa WT210 Power Analyzer was used to measure all electrical characteristics of the sample.

CSA is an accredited Test Laboratory (TL-430)

to IESNA LM79-08 by IAS (International Accreditation

Service)

National Voluntary Laboratory Accreditation Program

(NVLAP)200732-0

Page 15: Sample Tested ARE-EDG-4M-XX-06-E-UL-XX-700-40K-XXXX …...IES Classification Semi-Cutoff, Type III –Short ‡Based upon IES file generated output –Total Lumens may differ from

Report: 2650044-11

Project: 2650044

Client: Cree Inc.

6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134

Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948

www.csagroup.com Page 15 of 15

All equipment is calibrated to ISO / IEC 17025-2005 guidelines.

Equipment List: Sphere C Equipment

Description Manufacturer and

Model Number

CSA Instrument

Reference Number

Calibration Due

Date

Integrating Sphere 76” Labsphere LMS760 SPH300 N/A

Spectroradiometer Labsphere CDS1100 CDS600C N/A

Auxiliary Lamp PSU Labsphere LPS100 LPS100 N/A

Power Analyzer Yokogawa WT210 PA112 1/2014

Regulated Power Supply Chroma Instruments 61603 AC302 N/A

Equipment List: Goniophotometer Type C (Mirror 1)

Description Manufacturer and

Model Number

CSA Instrument

Reference Number

Calibration Due

Date

Optometer Gigahertz Optik P9801 N/A N/A

Regulated Power Supply Chroma Instruments 61602P-

80-60 N/A N/A

Regulated Power Supply Chroma Instruments 61602 N/A N/A

Power Analyzer Yokogawa WT210 POA400 11/2013