A B C D 2 5 5 6 6 SUMP 1 SUMP 2 A B 275 275 275 600 3293 2088 600 275 2 675 600 275 275 100 600 275 SSL 70775 1... All dimensions in millimetres unless otherwise. 2... All levels in metres above Ordnance Datum 3... For Location of sections Refer to Drg.37661/001 & 002 4... For reinforcement details refer to Drg.37661/ NOTE ALL CONCRETE IN BASEMENT RAFT SLAB, SUMP PIT AND BASEMENT RETAINING WALLS TO BE PUDLO WATER-TIGHT CONCRETE CONSTRUCTED STRICTLY IN ACCORDANCE WITH CURRENT PUDLO SYSTEM SPECIFICATION USING DETAILS CONFORMING TO CURRENT RECOMMENDATIONS AND REQUIREMENTS OF PUDLO CONCRETE KEY SYMBOL DESCRIPTION PUDLO CONCRETE NORMAL CONCRETE www.eastwoodandpartners.com [email protected] St. Andrew's House 23 Kingfield Road Sheffield S11 9AS 0114 255 4330 0114 255 4554 Fax Tel Information within this drawing is not necessarily produced to scale. Always use figured dimensions and co-ordinates - if in doubt ask. NOTES A First Issue. REV DESCRIPTION SIG CHK DATE SCALE WHEN PLOTTED AT A1 DRAWING STATUS DRAWN CHECKED DATE E & P DRAWING NUMBER REV / BIM PROJECT DRAWING NUMBER Author Checker 06/18/15 BEWLEY HOMES HARTLEY WINTNEY PLOTS 1 & 2 SUMP PIT PLAN & DETAILS Project Status 37661 005 ENLARGED PLAN ON SUMP PITS SECTION 5 - 5 SECTION 6 - 6 Note: SUMP PIT SIZED FOR NEWTON TPW TITAN PRO WHITE PACKAGE PUMP SYSTEM. IF A DIFFERENT PACKAGED PUMP SYSTEM IS TO BE USED, CONTRACTOR SHOULD VERIFY SUMP PIT SIZE. 3D VIEW SECTION THROUGH SUMPS

Transcript of SAMPLE REVIT DRAWINGS-SUNIT K DHINGRA-COMPLETE - EASTWOODS

Page 1: SAMPLE REVIT DRAWINGS-SUNIT K DHINGRA-COMPLETE - EASTWOODS

A B C D

2

55

6

6

SUMP 1 SUMP 2

A B

275

275 275600

3293

2088

600

275

2

675 600

275 275

100

600

275

SSL 70775

1... All dimensions in millimetres unless otherwise.

2... All levels in metres above Ordnance Datum

3... For Location of sections Refer to Drg.37661/001 & 002

4... For reinforcement details refer to Drg.37661/

NOTE

ALL CONCRETE IN BASEMENT RAFT SLAB, SUMP PIT AND BASEMENTRETAINING WALLS TO BE PUDLO WATER-TIGHT CONCRETE

CONSTRUCTED STRICTLY IN ACCORDANCE WITH CURRENT PUDLOSYSTEM SPECIFICATION USING DETAILS CONFORMING TO CURRENT

RECOMMENDATIONS AND REQUIREMENTS OF PUDLO

CONCRETE KEY SYMBOL DESCRIPTION

PUDLO CONCRETE

NORMAL CONCRETE

[email protected]

St. Andrew's House23 Kingfield RoadSheffieldS11 9AS

0114 255 43300114 255 4554

FaxTel

Information within this drawing is not necessarily produced to scale. Always use figureddimensions and co-ordinates - if in doubt ask.

NOTES

A First Issue.

REV DESCRIPTION SIG CHK DATE

SCALE WHEN PLOTTED AT A1 DRAWING STATUS

DRAWN CHECKED DATE E & P DRAWING NUMBER REV

/BIM PROJECT DRAWING NUMBER

Author Checker 06/18/15

BEWLEY HOMES

HARTLEY WINTNEY

PLOTS 1 & 2 SUMP PIT PLAN & DETAILS

Project Status

37661 005

ENLARGED PLAN ON SUMP PITS

SECTION 5 - 5

SECTION 6 - 6

Note:SUMP PIT SIZED FOR NEWTONTPW TITAN PRO WHITEPACKAGE PUMP SYSTEM.IF A DIFFERENT PACKAGEDPUMP SYSTEM IS TO BE USED,CONTRACTOR SHOULD VERIFYSUMP PIT SIZE.

3D VIEW SECTION THROUGHSUMPS

Page 2: SAMPLE REVIT DRAWINGS-SUNIT K DHINGRA-COMPLETE - EASTWOODS

SSL 70.400

SSL 70.775

TOC 73.550

A

275

275

276 100

ENGINEERED TIMBER FLOOR JOISTS TOMANUFACTURERS DESIGN

JOIST FIXED TO TIMBER PLATE USINGJOIST HANGERS

250x50 TIMBER PLATE FIXED TO RC WALLUSING HILTI M12 HAS-TZ RODS AT 400 c/cAND HILTI HVUADHESIVE

DRAINED CAVITY SYSTEM BY OTHERS

INSULATION TO ARCHITECTS DETAILS TOINSIDE FACE OF BASEMENT

RC CONCRETE SLAB IN PUDLOWATER RETRAINT CONCRETE

CAVITY TRAY

CELLCORE HX S 160mm 9/13 ONON 50mm CONCRETE BLINDINGUSING FN027 CONCRETE.

75mm THICK CLAYMASTER BY CORDEKOR EQUAL APPROVED COMPRESSIBLEMATERIAL

PUDLO WATERRESISTING CONCRETE

ANCON BRICK TIESANCHORED INTO CAST-INOMEGA CHANNEL

MASS CONCRETE PADSOR TRENCHFILLFOUNDATIONS

5004

1

138

JOIST FIXED TO TIMBER PLATE USINGJOIST HANGERS

250x50 TIMBER PLATE FIXED TO RC WALLUSING HILTI M12 HAS-TZ RODS AT 400 c/cAND HILTI HVUADHESIVE

INSULATION TO ARCHITECTS DETAILS TOINSIDE FACE OF BASEMENT

DRAINED CAVITY SYSTEM BY OTHERS

FINISHES AND INSULATIONTO ARCHITETCS DETAILS

SSL 70400

275

A

B

275

275

275

275 275

600

BITUTHENE LM TO CAVITYFACE OF INNER LEAF, TOBE LAPPED INTO PUDLORC BASEMENT WALL LINKEDTO CAVITY TRAY.

ENGINEERED TIMBER FLOORJOISTS TO MANUFACTURERS DESIGN

SSL 73650 GROUND FLOOR

JOISTS FIXED TOTIMBER PLATE USINGJOIST HANGERS

INSULATION TO ARCHITECTS DETAILSTO INSIDE FACE OF BASEMENT WALLS

DRAINED CAVITYSYSTEM BY OTHERS

SSL 70775 BASEMENT FLOOR

FINISHES AND INSULATION TOARCHITECTS DETAILS

RC CONCRETE SLABIN PUDLO WATER RESISTANTCONCRETE

FFL 71000

150

KICKER

6

6

C

300

PLOT 1PLOT 2

SSL 70775 BASEMENT

RC CONCRETE SLABIN PUDLO WATER RESISTANTCONCRETE

275

CELLCORE HX S 160mm9/13 ON 50mm CONCRETEBLINDING

FINISHES AND INSULATIONTO ARCHITECTS DETAILS

TOC 73.550

A

275

ENGINEERED TIMBER FLOOR JOISTS TOMANUFACTURERS DESIGN

JOIST FIXED TO TIMBER PLATE USINGJOIST HANGERS

250x50 TIMBER PLATE FIXED TO RC WALLUSING HILTI M12 HAS-TZ RODS AT 400 c/cAND HILTI HVUADHESIVE

1... All dimensions in millimetres unless otherwise.

2... All levels in metres above Ordnance Datum

3... For Location of sections Refer to Drg.37661/001 & 002

NOTE

ALL CONCRETE IN BASEMENT RAFT SLAB, SUMP PIT AND BASEMENTRETAINING WALLS TO BE PUDLO WATER-TIGHT CONCRETE

CONSTRUCTED STRICTLY IN ACCORDANCE WITH CURRENT PUDLOSYSTEM SPECIFICATION USING DETAILS CONFORMING TO CURRENT

RECOMMENDATIONS AND REQUIREMENTS OF PUDLO

CONCRETE KEY SYMBOL DESCRIPTION

PUDLO CONCRETE

NORMAL CONCRETE

[email protected]

St. Andrew's House23 Kingfield RoadSheffieldS11 9AS

0114 255 43300114 255 4554

FaxTel

Information within this drawing is not necessarily produced to scale. Always use figureddimensions and co-ordinates - if in doubt ask.

NOTES

A First Issue.

REV DESCRIPTION SIG CHK DATE

SCALE WHEN PLOTTED AT A1 DRAWING STATUS

DRAWN CHECKED DATE E & P DRAWING NUMBER REV

/BIM PROJECT DRAWING NUMBER

Author Checker 06/17/15

BEWLEY HOMES

HARTLEY WINTNEY

SECTIONS

Project Status

37661 004

SECTION 1 - 1

SECTION 2 - 2 SECTION 3-3

SECTION 4 - 4

JOIST BEARING DETAIL

Page 3: SAMPLE REVIT DRAWINGS-SUNIT K DHINGRA-COMPLETE - EASTWOODS

A B C D

1

2

3

E

3293 2655 2655

3767

6969

3293

33

11

2

2

44

275mm THICK PUDLO CONCRETE RC SUSPENDEDBASEMENT SLAB

SSL 70.775

275mm THICK PUDLO CONCRETE RC SUSPENDEDBASEMENT SLAB

SSL 70.775

275mm THICK RC WALL-2

275m

m TH

ICK

RC W

ALL-

1

275m

m TH

ICK

RC W

ALL-

3

SUMP FOR DRAINAGE CAVITYREFER TO DRG. 37661/004

SUMP FOR DRAINAGE CAVITYREFER TO DRG. 37661/004

55

240

399

[email protected]

St. Andrew's House23 Kingfield RoadSheffieldS11 9AS

0114 255 43300114 255 4554

FaxTel

Information within this drawing is not necessarily produced to scale. Always use figureddimensions and co-ordinates - if in doubt ask.

NOTES

A First Issue.

REV DESCRIPTION SIG CHK DATE

SCALE WHEN PLOTTED AT A1 DRAWING STATUS

DRAWN CHECKED DATE E & P DRAWING NUMBER REV

/BIM PROJECT DRAWING NUMBER

Author Checker 06/19/14

BEWLEY HOMES

HARTLEY WINTNEY

BASEMENT PLAN

Project Status

37661 003

Page 4: SAMPLE REVIT DRAWINGS-SUNIT K DHINGRA-COMPLETE - EASTWOODS

A B C D

1

2

3

E

800

900

800RC BASE TYPE 2

RC BASE TYPE 1 RC BASE TYPE 2

RC BASE TYPE 3 RC BASE TYPE 3

800 900 800

1400

ZONE FOR SERVICES ACCESS

ZON

E FO

R S

ERVI

CES

AC

CES

S

3767

6969

700

ZON

E FO

R S

ERVI

CES

AC

CES

S

600 600 600 750825

3293 2655 2655 3293

PLOT 1 PLOT 2 466

LATERAL HEAVE PROTECTION

2813

4156

33

11

2

2

44

750m

m W

IDE

MASS

CON

CRET

E TR

ENCH

FILL

825m

m W

IDE

MASS

CON

CRET

E TR

ENCH

FILL

MASS CONCRETE TRENCH FILLMASS CONCRETE TRENCH FILL

55

600

600

275

275

675

275275

55

600

600

275

275

675

275 275

IFL 70.00OGL 74.50FGL 73.65 IFL 70.20

OGL 74.00FGL 73.65

IFL 70.00OGL 73.50FGL 73.65

IFL 69.70OGL 73.00FGL 73.65

IFL 69.40OGL 72.35FGL 73.65

IFL 69.50OGL 73.00FGL 73.65

IFL 68.60OGL 70.70FGL 71.00

IFL 68.85OGL 70.95FGL 71.00

1... All dimensions in millimetres unless otherwise.

2... All levels in metres above Ordnance Datum

3... This drawing is based on K.L. Skalka Architects DrawingBH338-S3-01 Rev D date 06/03/15.

4... Substructure design based on Geotechnical Report by Ground Investigation Services (Southern) Ltd, reference S. 4303 dated October 2013.

5... The following designated concrete mixes to be used: Mass Concrete Trenchfill - FND 2z Pad Bases Reinforced concrete Trenchfill - FND 2z

6... The polystyrene used as a precaution against soil heave must have a density no greater than 11kg/m³ and must be designated as highly compressible and suitable for this usage eg. Claymaster by Cordek Ltd (tel: 01403 799601)

7... Backfill to substructure walls should be left uncompacted

8... Footings for houses to extend to the deepest of the following:

a) To the intended founding level (IFL) shown on plan

b) To undisturbed natural ground with an allowablebearing capacity of 125kN/m²

c) To a depth which will not surcharge adjacent drainsor footings.

9... All substructure blockwork and mortar to be suitable for Design Sulphate Class DS2z and Aggressive Chemical Environment for Concrete AC-2z.

10...For Sections refer to drawing 37661/040

SETTING OUT

ALL TRENCHFILL FOUNDATIONS TO BE 600mm WIDE AND CENTRED ONGRID LINES UNLESS NOTED OTHERWISE

ALL CONCRETE PAD BASES REINFORCED & CENTRED ON GRID LINES UNLESSNOTED OTHERWISE

FOUNDATION SCHEDULE

MEMBER NAME MEMBER SIZE T.O.C LEVEL No.OFFBASE TYPE 1 1800x1800x400 THICK 70.4 1

BASE TYPE 2 1600x1600x400 THICK 70.4 2

BASE TYPE 3 1400x1400x400 THICK 70.4 4

[email protected]

St. Andrew's House23 Kingfield RoadSheffieldS11 9AS

0114 255 43300114 255 4554

FaxTel

Information within this drawing is not necessarily produced to scale. Always use figureddimensions and co-ordinates - if in doubt ask.

NOTES

A First Issue.

REV DESCRIPTION SIG CHK DATE

SCALE WHEN PLOTTED AT A1 DRAWING STATUS

DRAWN CHECKED DATE E & P DRAWING NUMBER REV

/BIM PROJECT DRAWING NUMBER

Author Checker 06/10/14

BEWLEY HOMES

HARTLEY WINTNEY

FOUNDATION

Project Status

37661 002

BASE TYPE 2

BASE TYPE 1

BASE TYPE 2

FOUNDATION PLAN

3D VIEW SHOWING FOUNDATIONS