Safety Light Grid SLG 422/425I-P
Operating Manual
Reflection mirror ULS-P-0501
1 Introduction 011.1 EU regulations 01
2 Safety Functions 012.1 General conventions for safe use 01
3 Description 023.1 Basic information 023.2 Features 023.3 Safety functions 023.3.1 Start interlock 023.3.1.1 Automatic mode 023.3.2 Restart interlock 023.3.3 Testing 033.4 Diagnosis window 033.4.1 LED status information 03
4 Mounting 044.1 Installation requirements 044.1.1 Detection zone and approach 044.1.2 Alignment of transmitter and receiver 044.1.3 Safety distance determination 044.1.4 Minimum distance to reflective surfaces 05
5 Operating mode Muting 075.1 Intended use 075.2 Content and scope of the document 075.3 Definition 075.4 Safety instructions 075.5 External components 085.5.1 Muting sensors MS 085.5.2 Muting lamp 095.5.3 Illuminants 095.6 Muting operation signal sequence 095.7 Basic setting of the muting function with BUS Converter NSR-0801 095.8 Setting for muting operation 105.9 Operating mode and transport direction 105.9.1 Muting cycle duration 105.9.2 Simultaneousness of the sensors 105.9.3 Restart interlock 115.9.4 Conveyor stop 115.9.5 Muting cycle shortened 115.9.6 Override 115.9.7 Multiple break of protective field during muting cycle 125.10 Storage of information 125.11 Muting applications 12
6 Connections 156.1 Wiring diagram SLG 422P 156.2 Wiring diagram muting SLG 425IP 166.3 Connection of Muting function cables 176.4 Sensor connection 176.5 Power supply 17
7 Testing and initiation 187.1 Check list 187.2 Troubleshooting 187.3 Diagnostic operation 18
8 Technical characteristics 198.1 Technical characteristics 198.2 Dimensioned drawings 208.2.1 Dimensioned drawings standard 208.2.2 Dimensioned drawings muting 218.2.3 Dimensioned drawings ULS-P-0501 228.3 Mounting accessories 228.3.1 Mounting set MS-1030 228.3.2 Middle mounting bracket MS-1051 238.4 Response time 238.5 List of Type 238.5.1 Order numbers 23
Table of contents
9 Accessories 249.1 Accessories included in the delivery package 249.2 Optional accessories 24
10 Safety Instructions 2510.1 Inspection according to machine maintenance 2510.2 Inspection every six months 2510.3 Cleaning 25
11 Contact 26
12 Annex 27
Inhalt
The aim of this document is to provide instructions to the skilled operator to properly install, configure, initiate, test and maintain the safety light grid SLG422/425I-P.
When using the safety light grid please be sure to heed the following recommendations:- Make sure that the people operating the machine have been informed of the installation of SLG422/425I-P.- Read the entire installation manual before initiating SLG 422/ 425I-P .- Keep the manual in a suitable location so that it is available at all times.
1.1 EU Regulations
(1) SLG 422/ 425I-P is an opto-electronic self testing protective device in accordance with the regulations of the European Union (EU), Machinery directive, Annex 4, B Safety Components, Item 1.
(2) It complies with the following regulations and standards:
- EN 61496-1:2004 - CLC/TS 61496-2:2006 - EN 62061:2005, SIL 3 - EN ISO 13849-1:2006, Category 4, Performance level "e"
2.1 General conventions for safe use
The following conventions are preventive warning instructions in order to ensure safe and proper handling of SLG 422/ 425I-P.They form an integral part of the safety instructions and thus have to be followed at all times.
! Attention A potentially hazardous situation which might result in death or serious injury.
The safety light grid SLG 422/ 425I-P can be used to safeguard danger spots on machines or applications which in a risk analysis have category 4 according to EN 954-1.
- Never use SLG 422/ 425I-P on machines that cannot be stopped by electrical emergency shut down.
- The safety distance between SLG 422/ 425I-P and hazardous machine movements must be maintained at all times. (s. chapter 4.1 Installation requirements)
- Additional mechanical safety precautions are to be installed in a way that dangerous machine parts can not be reached without passing through the detection zone. (s. chapter 4.1 Installation requirements)
- Install SLG 422/ 425I-P in a way that the operator's body is always within the detection zone when operating the machine. Failure to do so may result in serious injury.
- Do not short the output lines to the +24V/DC line. Doing so will cause the outputs to be ON, i.e. they cannot stop a dangerous situation in the application/on the machine.
- Safety inspections must be carried out at regular intervals (s. chapter 10.1, 10.2).
- Do not expose SLG 422/ 425I-P to flammable or explosive gases.
- Do not disassemble, repair or modify SLG 422/ 425I-P.
- The extension cables must be connected according to the installation instructions. The fastening screws of the end caps and the brackets must be secured tightly.
Subject to technical changes Page 1
Inadmissible action.
! Warning
1 Introduction
The multi-beam-light-grid SLG422/425I-P is an opto-electronical safety-device for safeguarding dangerspots against accidental access.
- EU-Machinery directive no. 98/37
2 Safety Functions
Safety light grid SLG 422/ 425I-P
(3) The safety light grid was tested and approved by the EU notified corporation of TÜV Nord. The compliance with the European Union regulations was confirmed (see EC-Declaration of conformity).
3.1 Basic Information
The Safety light grid SLG 422/ 425I-P is a self-checking electro-sensitive protective system based on infrared light.The system is offered in two variants:
SLG 422PSLG 425IP
The system can be used for
- Safeguarding of danger zones - Safeguarding of access areas- Automatic material transport
3.2 Features
The system is composed of a transmitting-/receiving-unit and a reflection-mirror. No additional switching elements are required for the functions described. A comfortable software program for diagnosis and function selection is available. For this purpose a BUS-Converter NSR-0801 is available (see Accessories).
The SLG 422/425IP grids provides following properties:
- start interlock- restart interlock- relay monitoring EDM (only 422P)- muting (only 425IP)
3.3 Safety Functions
The SLG 422/ 425I-P System without accessories offers a great variety of functions. The following table shows the possible functions and the system configuration of the factory settings.
3.3.1 Start interlock
The start interlock prevents an automatic machine start after power ON.After release of the start interlock by a single interrupt of the detection zone this protection function will beinactive until the next voltage reset.When delivered the start interlock is not active. This function can be activated using the BUS-Converter NSR-0801 and a PC / Laptop (see manual NSR-0801).
3.3.1.1 Automatic mode (Automatic start after release of detection zone)
The Automatic mode function switches the OSSD outputs ON (detection zone not interrupted) without external release of a switching device. This mode of operation must be selected in combination with the restartinterlock of the machine. This degree of protection initiates an automatic restart of the machine while the protective zone is not interrupted. Do not select this operation mode when operators can pass through the protective zone.
This operation mode can be selected via cable link between the connections DIAG OUT and Release.
DIAG OUT
Release/Override
serious injury or death.
3.3.2 Restart Interlock
The Restart Interlock prevents an automatic release of the outputs (OSSDs ON) after feeding in the linevoltage or after an interruption of the protective zone.The system switches the output back to ON, if an external device (restart button) creates a release signal on theinput Restart (receiver).
Page 2 Subject to technical changes
! WarningWhen this mode is selected, operators or maintenance workers may enter the danger area without detection. Take care by the control system of the machine that restart interlock is always active. Failure to do so may result in
BUS-Converter NSR-0801Relay monitoring EDM/muting (see 3.2)
Safety light grid SLG 422/ 425I-P
-
not active BUS-Converter NSR-0801Start interlock not activeRestart Interlock activeFunction Factory settings Configuration
3 Description
Note:In the delivery package the restart interlock is not active. You must select this degree of protection (Wiring see chapter 4.3), or else the OSSD outputs will not be released. If no degree of protection has been selected, the status indication of the LEDs in the receiver will produce the following signal:
Activating the Restart Interlock
This operating mode can be selected via a cable wiring between the connections DIAG OUT and DIAG in.
DIAG OUT
DIAG IN
The electrical connection is described in the chapter Wiring diagram.
3.3.4 Relay monitoring (EDM)
This function monitors the triggered switch elements (auxiliary relay contacts) of the two outputs after each interruption of the detection zone and before the restart (release) of the outputs. This helps to recognize defective functions of the relays, e.g. smoldering of the contacts, rupture of the relay spring.
If the light curtain detects a defective function of the switch elements the outputs will be locked, i.e. a powerreset must be carried out after the correction.
When delivered, the relay monitoring function is not activated. This function can be activated using aBUS converter NSR-0801, software >4.0 and a PC/Laptop. How to connect the cables is described in chapter wiring diagram.
3.3.3 Testing
Test after Power ON
After switching Power ON, the system carries out a complete self and safety test within 2 seconds.If the detection zone is uninterrupted, the system switches to ON.If an error occurs, the outputs at the receiver will not switch ON. The OSSD OFF LED will flash to signal an error message. For further information please refer to chapter 7.2 Error diagnosis.
Permanent self test
In the background, the system checks all safety functions within the cycle time. This time includes a check of all functional components and a complete memory test.
3.4 Diagnosis Window
Function LED colourMulti function greenBlanking blueSignal receipt orangeRestart yellowOSSD OFF redOSSD ON green
3.4.1 LED status information
SLG 422/ 425I-P
LED Status LED DescriptionOSSD ON ON Detection zone uninterrupted
flash Diagnostic mode activatedOSSD OFF ON
flashRestart ONSignal receipt ON/flash
ON/flashOFF
Multi function 1 x blinken Muting (entire protective field)2 x blinken Muting (only protective field acc. Teach)3 x blinken Muting via BUS control4 x blinken5 x blinken
Subject to technical changes Page 3
LED OSSD OFF (red) + LED restart (yellow) flash
Safety light grid SLG 422/ 425I-P
function indication
Alignment between SLG* and ULS* is OK
res.Beam coding A is active
detection zone area(s) are inactive (blanking)
input for control switch
Detection zone interrupted, system or configuration error
processing of the received signal
safety outputs signal status OFFsafety outputs signal status ON
Description
Start/Restart interlock active, signal expected at input RestartDiagnostic mode activated, error message refer to Troubleshooting
Signal reception too weak; check alignment and installation height betweentransmitter and receiver.clean the black profile cover
SLG422/425I-P
Multi function
Blanking
Signal receipt
OSSD OFF
OSSD ON
Restart
protective area
4.1 Installation requirements
4.1.1 Detection zone and approach
The protective field of the SLG 422/ 425I-P is 500 mm. The output and input of the beam is shown in the dimensioned drawing. Install additional protective structures to make sure that the detection zone must be passed in order to reach dangerous machine parts.
Install SLG 422/ 425I-P in a way that users operating dangerous machine parts will always remain within the detection zone of the safety device.
4.1.2 Alignment of transmitter and receiver
Procedure:
1. The transreceiver must be arranged parallel to the reflection mirror and on the same height.
2. Turn the transreceiver, watching the diagnosis window of the transreceiver and fix the point, when the OSSD ON LED (green) flashes up and the LED Signal reception (orange) goes out.
3. Determine the max. left and right torsion angle and fix the fastening screws in center position. Check that the Signal reception LED does not flash.
4.1.3 Safety distance determination
Safeguarding of access areas with SLG 422/ 425I-P
S = Safety distance
mechanical protection
The safety distance is the minimum distance between SLG 422/ 425I-P and dangerous machine parts that has tobe kept to prevent access to the danger spot before the dangerous movement has stopped. The following equations and calculation examples refer to vertical adjustment of the safety light-curtainto the danger spot.
Calculation of the safety distance according to EN 999 and EN 294
The following factors are decisive when determining the safety distance:
- Machine after-running time (determined by measuring the after-running time)- Response time of machine and safety light grid (entire protective gear)- Approach speed- Resolution of the safety light grid
Page 4 Subject to technical changes
can be within the danger area before a dangerous movement is starting.
The respective beam position is marked by a countersink (D = 2 mm), directly at beam withdrawal, laterally on the profile.
4 Mounting
For the operation the legal and official regulations have to be considered.These can be different according to region and country.
! Attention
dangerous area is not possible. The dangerous area must be freely observable for the user when the control unitThe control unit (release button) has to be mounted outside the dangerous area that an operation from within the
(release button) is operated.
The safety distance from the danger place to the protection device SLG 422/ 425I-P has to be kept absolutely. The safety distance allows persons to stay within the dangerous area. It must be guaranteed that no person
Safety light grid SLG 422/ 425I-P
danger spotDirection of access to the danger zone
Command buttonRelease
S
Mirror
SLG
The safety distance for SLG 422/ 425I-P is calculated as follows:
S = ( 1600 mm/s * T ) + 850 mm
S = safety distance [mm]T = after-running time of the machine + reaction time of the safety light gridK = Approach speed 1600 mm/sC = Safety addition 850 mm
Example:Reaction time of SLG 422/ 425I-P = 10 msAfter-running time of the machine T = 170 ms
S = 1600 mm/s * (170 ms + 10 ms) + 850 mmS = 1138 mm
The following assembly heights have to be considered:
Number of beams
2
4.1.4 Minimum distance to reflective surfaces
Subject to technical changes Page 5
When installing SLG 422/ 425I-P the effects of reflection from specular surfaces must be considered. Improper
Assembly height overreference level (floor) in mm
400, 900
! Attention
Safety light grid SLG 422/ 425I-P
danger spot before the dangerous movement has stopped might get seriously injured.Always keep the safety distance between the SLG 422/ 425I-P and the danger spot. Any person that can reach the
installation might result in improper detection of detection zone interruptions and thus lead to serious injuries. When installing SLG 422/ 425I-P in close proximity to highly reflective surfaces (e.g.. metal walls, floors, ceilings or workpieces) strictly keep the following minimum distance a .
! Attention
Acces s d irection
Obs tacle
Optica l axis
Reflective s urface(e .g . con ta ine r)
Border of adangerous s pot
a = 105 m m
E/R un it A E/R unit B
4 4
Access direction
a = 130 mm
MirrorSLG 422/ 425I-P
Optical axis
Reflective surface(e.g. container)
Border of a dangerous spot
5° 5°
Obstacel
Table: Safety distance a
1000900800700600500400300200100
The effective aperture angle for the SLG 422/ 425I-P is +/- 4,0° (when L > 3,0 m) as provided by the IEC 61496-2.Install the SLG 422/ 425I-P away from reflective surfaces at an effective aperture angle of +/- 5,0° to take misalignment during installation into account. See following table:
Distance [m] between Minimum distance aSLG and ULS [mm]
0,2 bis 3,0 2624 3505 4376 525
Formula: a = tan 2,5° x L [mm]
a = Minimum distance to reflective surfacesL = distance between SLG 422/ 425I-P and mirror ULS
Page 6 Subject to technical changes
Safety light grid SLG 422/ 425I-P
a [mm]
D [m] 3 5 10 15 200
The Muting function is an integrated operating mode of the safety light grid SLG 425I-P.
The Muting function is only applicable for automatic material transport to secure access points of a danger zone. The material passes the access area across the protective field of the light grid without turning the outputs off.
Do not use this function for other purposes. We accept no liability for any application other than the intended use. We accept no liability due to non-observance of the subsequently described assembly and safetyinstructions and parameter adjustments.
This document contains information about the inteded bridging of the protective field of an AOPD and is reserved for people with the necessary specialised knowlege. Users of this document must be able to judge the hazards in connection with this mode of operation. The document does, however, not communicate the entire range of specialised knowledge required for the use of this operating mode. It is essential that all pertinent orders of authorities and legal regulations are complied with.
Some examples:EU-Machinery directive 98/37Guideline of the Employers' Liability Insurance Association (ZH 1/597)
Muting: transport
Muting sensor: Sensor for unambiguous material identificationMuting lamp: The muting lamp signals the muting statusOverride: The function enables a material transport after an unplanned stop of the muting
cylceConveyor stop: The muting runtime is interrupted while the signal Conveyor stop is activated.
- The bridging function aims at clearly differentiating between material and people in front of the danger zone. For this purpose 2 or 4 additional sensors must be connected depending on the intended use.
- The connection and the assembly of all components must be realised by specialists who are trained inelectronics and who know the appropriate safety regulations.
- Testing and initiation by competent experienced people who have the required specialised knowledge, especially of all pertinent legal and official regulations.
- Introduction and training by a specialist for the operators of the application.
After connection and assembly by a specialist please make sure that the following instructions are being observed:
- Arrangement of the sensors according to the instructions. It must be prevented that the muting function is started by unintentional interruption of the danger zone by any person stepping into the danger zone. The sensors mustbe arranged in a way that normal approach, eg. the movement of a foot, leg, hand or arm will not trigger the muting function.- The selection of the operating parameters, e.g. simultaneousness, muting duration, operating mode, special functions, etc. must be adjusted to the application, for example termination of the muting cycle after passing through the protective field.- The muting cycle must start automatically upon release by the control switch and be controlled by atleast 2 independent signals (sensors).- The control switch for the release and the override fuction must be arranged in a way that the entiredanger zone can be monitored. Be sure they are mounted in a way that they cannot be activated from within the danger zone.- The status of the muting function must be signalled by a muting light (see chapt. 5.5.2).
Subject to technical changes Page 7
5 Operating mode Muting
5.2 Content and scope of this document
5.3 Definition
Safety light grid SLG 422/ 425I-P
! Attention
5.4 Safety instructions
Intended short-term bridging of the outputs of an AOPD with automatic material
5.1 Intended use
5.5.1 Muting sensors MS
The muting sensor MS can be a mechanic, capacative, inductive or opto-electronic sensor. There is no specific requirement concerning error protection. The arrangement must be secured against manipulation. If reflexion light barriers are used we recommend to install sensors and reflectors in
to use a dark-switched type. (sensor dimmed = output 24 V/DC)
entire length without interruptions. The sensors must detect the material, not the means of transportation.
Make sure that the sensor distance is not too large, so that all activated muting sensors are dimmed by the passing material during a cycle. Simultaneousness (max. 3 sec) of the switch outputs must be taken into consideration.A new muting procedure can start as soon as the previous process is finished (sensors not dimmed).A safety distance of at least 50 mm (conveyor speed V < 2.0 m/s) to the protective field is required to ensure proper signal evaluation by the control unit.
Pin assignment of the sensors
PIN assignment in the sensor connector boxPIN Nr Signal Description
1 + 24V/DC3 OV4 + 24V/DC
Installation of the muting sensors
If 4 muting sensors are used the outputs of the sensors MS1 and MS3 and MS2 and MS4 must be connected in parallel. MS1 and MS3 are connected to the sensor connector plate at input MS1. Connect MS4 and MS2 to input MS2.
Connection of the sensors - 2 muting sensors
- 4 muting sensors
When arranging the muting sensors make sure that unintentional intrusion of a person into the danger zone is not possible. The distance and the height of the muting sensors must be appropriate for clear differentiation between material and person.
The wiring layout of the muting sensors to the AOPD must exclude cross circuiting due to defect cables.
Page 8 Subject to technical changes
Voltage supplyVoltage supply
Safety light grid SLG 422/ 425I-P
alternating order to avoid mutual interference. If you use opto-electronic sensors please make sure
The sensors must be arranged in a way that the transported piece of material is detected over the
Switch output of sensor
Attention!
5.5 External components
4
13
4
13
MS 2
ALFA 4sensor connection
MS 1
+ 24V / DC
MS 1 MS 2
MS 2
ALFA 4sensor connection
MS 1
+ 24V / DC
MS 1 MS 3 MS 2 MS 4
SLG 425IPSensor connection
SLG 425IPSensor connection
5.5.2 Muting lamp
The Muting mode must be indicated by an external lamp. Connect this lamp to the sensor connector plate (ML) using a 3 pin cable connector. The muting lamp is not monitored, i.e. the control unit of the SLG 422/425I-P does neither check the electric connection nor the illuminant.
5.5.3 Illuminants
The muting lamp requires an LED block with a lifecycle of 50,000 operating hours. We recommend to usethe muting lamp type MK2.
The light signals the following operating states:
Muting lamp SignalON continuous lightOFF
Blinking 2 Hz
Blinking of the muting light may indicate the following errors:Muting cycle duration exceeded.Conveyor stoppage time exceeded.Non-observance of sequence or simultaneouness of signal states of MS.
Wiring of the muting lamp:Pin assignment
PIN assignment in the sensor connector boxPIN Nr Signal Description
1 + 24V/DC3 OV4 + 24V/DC
The muting cycle is started upon activation of the switch outputs of two muting sensors. The signal sequence and the muting state are shown in the following graph.
Parameter setting: Muting operation with 2 sensors, directional detection 1, premature termination not active
The muting function is activated after MS 1 and subsequently MS 2 have been dimmed by the material. (directional detection 1). Next, the material dims the protective field of SLG 420, MS 1 and subsequently MS 2 . The muting cycle is terminated as soon as MS 1 is no longer dimmed.
The parameters for the muting operation are set with the PC Software release SLC4Kunde.exe.Connect the BUS Converter NSR-0801 to the SLG 425IP and a PC/laptop. For wiring instructions please refer to the manual of the BUS Converter NSR-0801.
Subject to technical changes Page 9
Voltage supplyVoltage supplySwitch output ML
Muting cycle error or override operation
Safety light grid SLG 422/ 425I-P
5.6 Muting operation signal sequence
5.7 Basic setting of the muting function with BUS Converter NSR-0801
CommentMuting cycle activeMuting cycle not active
t<3s
MS 2
Muting
ML
MS 1 *1
*2
*2
*2
*2
*1
*1
*1
*1: aktiv*2: inaktiv
t<3s
4
13
4
13
When you have properly connected the muting application and the NSR-0801, select the following parameter settings according to your intended application in the menu option Muting Function of your PC software.
First please select the operating mode and the transport direction with the mouse pointer (arrangement and number of muting sensors).
- Muting with 2 sensors, diagonal arrangementMuting mit 2 diagonally mounted muting sensorsTransport direction: Material transport in two directions (default) Selectable options: Conveyor stop, muting cycle shortened, override, protective field range
- Muting with 2 sensors, parallel arrangementMuting with 2 muting sensors; Attention! Do not mount the muting sensors outside of the danger zone!Transport direction: out of the danger zone, muting cycle shortened (default). Selectable options: Conveyor stop, override, protective field range
- Muting with 4 sensors, parallel arrangementMuting with 2 muting sensors each, symmetrical arrangement in front of and after the protective field of the SLG 420. Transport direction: Material transport selectable in both directionsSelectable options: Conveyor stop, muting cycle shortened, override, protective field range
5.9.1 Muting cycle duration
The muting cycle duration is the time between activation and termination of the material tansport into or out of the danger zone.The muting cycle duration depends on the length of the material, the conveyor speed and the arrangement of the sensors. The duration setting must comprise one complete muting cycle (release of all sensors). A newmuting cycle can only be started when all sensors are released (no dimming).
The muting cycle duration can be set between a few second and many hours. Longer muting cycle durations can be generate a dangerous operating situation.Consider variations of conveyor speed, position and length of the material when setting the muting cycle duration.
5.9.2 Simultaneouness of the sensors
The time range between the 1st and the 2nd muting sensor is monitored. Thus a symmetrically shaped body can be differentiated clearly from other time ranges (intrusion of a person) by an appropriate arrangement of the muting sensors.The simultaneouness setting should take variations of the conveyor speed, position and length of the material into consideration.
Simultaneouness of the sensors can be set between 1 and 3 seconds.
Page 10 Subject to technical changes
5.9 Operating mode and transport direction
5.8 Setting for muting operation
Safety light grid SLG 422/ 425I-P
We recommend the setting of the following special functions. Thus you will increase the protective function and the availability of the muting application.
5.9.3 Restart Interlock
The restart interlock prevents automatic conveyor start after voltage interruption or material jam. The restart interlock must be wired according to the wiring diagram on page 17. When delivered the function is activated.The control switch must be installed outside of the danger zone so that the zone can be monitored from all sides. The control switch must be activated after each voltage or protective field interruption or when an error in the muting cycle occurs. Release is only possible when none of the sensors is dimmed. A status LED on the receiver indicates when the control switch must be activated.
The function can be deactivated with the mouse pointer. In this case the user must ensure this function with his application.
Attention !Deactivating the restart interlock may start an automatic muting cycle. People can now step into the danger zone and people in the danger zone may be severely injured!
5.9.4 Conveyor stop
The function can extend the muting cycle duration in case of an unintentional conveyor stop or material jam and thus prevent overflow. The muting function can be prolonged unit the interruption has been removed. Afterwards the normal muting cycle can continue as specified.
The Conveyor stop input is provided as signal from the machine control. If the function is activated, a signal of+ 24 V/DC must be connected in non-operative state. A change of state of the muting sensors (switchoutput) while the function is active switches the muting function off.
When delivered the function is not activated. The conveyor stop time can be set between 1 and 30 minutes.For applications with very long muting cycle duration the conveyor stop time can be prolonged by max. 18 hours.
5.9.5 Muting cycle shortened
A normal muting cycle is terminated by a muting sensor as follows:
- Muting with 2 sensors, diagonal arrangement, after release of sensor MS 2 - Muting with 4 sensors, parallel arrangement, after release of sensor MS 3
A very long muting cycle duration produces a time window with bridged protective field, during which the object is between the protective field and the muting sensor MS2/MS 3.
Activating the function means shortening the muting cycle. The bridging is terminated as soon as the material has passed the protective field of SLG 425IP (protective field free).
The function is always active in an application with 2 muting sensors in parallel arrangement. In an application with 2 diagonal sensors or 4 parallel sensors the function can be activated using the mouse pointer.
A new muting cycle can only be started when none of the muting sensors are dimmed.
5.9.6 Override
Use this function to bridge the outputs of the SLG 422/425I-P in case of an interrupt (voltage interrupt, material jam). The function has a time restriction and is expressly intended for the removal of the material jam (muting sensor or protective field dimmed).
When this function is activated the control switch can be used (release restart interlock) to start a material transport.The control switch can be activated switching ON-OFF-ON. The time sequence for the start (ON-OFF-ON) with a minimum duration of 100 ms up to a maximum duration of 1.5 sec must be taken into consideration. The Conveyor stops as soon as the material jam has been removed (protective field and muting sensors no longer dimmed. To start a new muting cycle you must release the restart interlock by activating the same control switch once (ON-OFF).The muting light blinks (2 Hz) to signal the interruption of the muting cycle. When delivered the function is not activated.
Subject to technical changes Page 11
Safety light grid SLG 422/ 425I-P
5.9.7 Multiple break of protective field during muting cycle
This function increases the systems' availability for variable goods on a pallet. During the active muting cycle theprotective field is guarded and leads to an immediate stop of the muting cycle when no beam is interrupted.This malfunction is triggered, i.e. when the means of conveyance with an irregular load of material does not dampall active beams of the protective field for a time longer than 20 ms.
If this function is activated, no break of the muting cycle will occur due to non-damping the beams. The functionallybreak is being realised by the respective configuration and as the case may be by the muting sensors.Combining the parameters with ' shortened muting cycle' is not possible.Those kind of restrictions will be indicated by the software's pop-up-windows.
After a new configuration the information are prepared for storage by activating the button
To prevent unintentional storage of the information, every intended storage processs must be confirmed byclicking an additional button
within 10 seconds. If you click this button within the given period, the new configuration will be transmitted tothe safety light grid SLG 425I-P. If you fail to press the button within the requested time, the information will be cancelled and the settings ofbefore your change will be stored.
After the data transmission the following confirmation appears. At the same time you will be asked to save the configuration data as text file.
We urgently recommend to do so. At a later time you will thus be able to trace the configuration changes. Click on the button (Ja / Yes) with the mouse pointer.Now you can save the configuration settings on your PC/laptop.
Assembly of muting sensors
Page 12 Subject to technical changes
Save setttings
Confirm storage within 10 seconds
5.11 Muting applications
5.10 Storage of information
Safety light grid SLG 422/ 425I-P
Muting-Sensor
R e f l e c t o r
SLG 425 IP
S1 = Distance of inner MS to PFS2 = Distance between 2 MSS3 = Length of the material
MS 1 = Muting sensor 1MS 2 = Muting sensor 2MS 3 = Muting sensor 3MS 4 = Muting sensor 4AOPD = Active opto-electronic
ULS = MirrorTRU = emitting-/receiving-unit SLG 425IPVB = Conveyor speed (m/s)
Minimum distances of muting sensors
A mimimum distance for the muting sensors is required that the control unit of the AOPD can evaluate the signals.
The signal length between the sensors closest to the AOPD must not be at less than 50 ms. This corresponds to a minimum distance of 100 mm at a conveyor speed of 2.0 m/s.
The minimum signal length of the outer sensors must be greater than 50 ms. The signal run time between the muting sensors must not exceed 3 seconds.
The assembly distance of the inner sensors to the protective field of the SLG 425IP should be as low as possible.
The sensors (emitter/receiver) of the SLG 425IP must be fixed as close as possible to the transported material to prevent gaps. Otherwise there is a risk of people getting between material and arrangement of the MSduring the muting cycle.
If you work with different material dimensions (width) make sure to protect the gap between the sensors (emitter/receiver) with an additional cover.
- Muting with 2 sensors, parallel arrangement
The arrangement shows the muting application with two parallel sensors. This arrangement allows for material transport out of the danger zone in only one direction.
S1 = Distance MS 1 to PFS2 = Distance MS 1 to MS 2S3 = Length of the material
MS 1 = Muting sensor 1MS 2 = Muting sensor 2ULS = MirrorTRU = emitting-/receiving-unit SLG 425IPVB = Conveyor speed (m/s)PF = protective field
S3 > S2 ; S1 = S2S1 = Conveyor speed VB (m/s) * 0,05 s
The muting cycle as follows: MS2- MS1- PF- End
Selectable options: Conveyor stop, override, protective field range
Default setting: Muting cycle shortened, i.e. muting cycle is terminated by release of protective field.
This arrangement is only admissible when the muting sensors are mounted within the danger zone.
Subject to technical changes Page 13
protective device
Safety light grid SLG 422/ 425I-P
- Muting with 2 sensors, diagonal arrangement
The arrangement shows the muting application with two sensors crosswise arranged. This arrangement enables material transport in two directions.
S1 = Distance MS 1 to PFS2 = Distance MS 2 to PFS3 = Length of material
MS 1 = Muting sensor 1MS 2 = Muting sensor 2ULS = MirrorTRU = emitting-/receiving-unit SLG 425IPVB = Conveyor speed (m/s)PF = protective field
The schematic diagram shows the arrangement of the muting sensors for unambiguous detection of the sensor sequence with greater distance. Please consider the smallest possible distance of the MS to the material to be transported. The distance between MS1 and MS2 to the protective field of the SLG 422/425I-Pmust be kept as low as possible.
S3 > S1 + S2 S1 = Conveyor distance VB (m/s) * 0,05 s
The muting cycle as follows: MS1- MS2- SF- MS 2 End
Selectable options: Conveyor stop, Override, muting cycle shortened, protective field range
Default setting: Material transport in both directions
Arrange the muting sensors in a way that a unique sequencing of the sensors is ensured.The intersection of the two muting sensors should always be within the danger zone.
- Muting with 4 sensors, parallel arrangement
The arrangement shows the muting application with four sensors in parallel. This arrangement enables the Material transport in both directions.
S1 = Distance of inner MS to PF S2 = Distance between two MSS3 = Length of material
MS 1 = muting sensor 1MS 2 = muting sensor 2MS 3 = muting sensor 3MS 4 = muting sensor 4ULS = MirrorTRU = emitting-/receiving-unit SLG 425IPVB = Conveyor speed (m/s)
S3 > 2(S1 + S2) ; S1 = S2S1 = Conveyor speed VB (m/s) * 0,05 s
The muting cycle as follows: MS1- MS2- SF- MS 3 EndMS4- MS3- SF- MS 2 End
Selectable options: Conveyor stop, Override, muting cycle shortened, protective field range
Default setting: Material transport in both directions
The arrangement with 2 muting sensors each has a symmetrical arrangement in front of and after the protective field of the SLG 425I-P.
Page 14 Subject to technical changes
Safety light grid SLG 422/ 425I-P
Bridge 1: Restart interlock active (bridge between DIAG OUT and DIAG IN)
K1, K2: Relay for further processing of outputs OSSD 1, OSSD 2Kn1, Kn2: Auxiliary contacts of the final relay (optional)S1: Control switch Release Restart (optional)E1: Power supply unit 24 V/DC +/- 10%
Subject to technical changes Page 15
Safety light grid SLG 422/ 425I-P
6 Connections
6.1 Wiring diagram SLG 422P
Mirror:ULS-P-5002 x 45° deflection
transmitter- receiver- unitSLG 422P
Erdung
E1
2 4 1 3 1 8 2 7 3 465
DIA
G IN
DIA
G O
UT
+24V
0V
Nur
für D
iagn
ose
DIA
G IN
DIA
G O
UT
Frei
gabe
WA
Sch
ützk
ontro
lle/E
DM
+24V
0V OS
SD
1
OS
SD
2
K1 K2
Brü
cke
2
Brü
cke
1
Kn1
Kn2
Erdung
E1
2 4 1 3 1 8 2 7 3 465
DIA
G IN
DIA
G O
UT
+24
V D
C
0 V
DC
Nur
für D
iagn
ose
DIA
G IN
DIA
G O
UT
Frei
gabe
WA
Sch
ützk
ontro
lle/E
DM
+24
V D
C
0 V
DC
OS
SD
1
OS
SD
2
K1 K2
Brü
cke
2
Brü
cke
1
Kn1
Kn2
S 1
Erdung
E1
2 4 1 3 1 8 2 7 3 465
DIA
G IN
DIA
G O
UT
+24V
0V
Nur
für D
iagn
ose
DIA
G IN
DIA
G O
UT
Frei
gabe
WA
Sch
ützk
ontro
lle/E
DM
+24V
0V OS
SD
1
OS
SD
2
K1 K2
Brü
cke
2
Brü
cke
1
Kn1
Kn2
Erdung
E1
2 4 1 3 1 8 2 7 3 465
DIA
G IN
DIA
G O
UT
+24
V D
C
0 V
DC
Nur
für D
iagn
ose
DIA
G IN
DIA
G O
UT
Frei
gabe
WA
Sch
ützk
ontro
lle/E
DM
+24
V D
C
0 V
DC
OS
SD
1
OS
SD
2
K1 K2
Brü
cke
2
Brü
cke
1
Kn1
Kn2
S 1
Erdung
E1
2 4 1 3 1 8 2 7 3 465
DIA
G IN
DIA
G O
UT
+24V
0V
Nur
für D
iagn
ose
DIA
G IN
DIA
G O
UT
Frei
gabe
WA
Sch
ützk
ontro
lle/E
DM
+24V
0V OS
SD
1
OS
SD
2
K1 K2
Brü
cke
2
Brü
cke
1
Kn1
Kn2
1 8 2 7 3 465
DIA
G IN
(gr
ey)
DIA
G O
UT
(pin
k)
Rel
ease
/Ove
rrid
e (w
hite
)
Con
tact
or c
ontro
l/E
DM
(red
)
+24
V D
C (b
row
n)
0 V
DC
(blu
e)
OS
SD
1 (g
reen
)
OS
SD
2 (y
ello
w)
K1 K2
Bridge 1 Kn1
Kn2
S 1
Earth
E1
Bridge 1: Restart interlock active (bridge between DIAG OUT and DIAG IN)
K1, K2: Relay for further processing of outputs OSSD 1, OSSD 2MK Machine contact conveyor stopS1: Control switch Release Restart (optional)E1: Power supply unit 24 V/DC +/- 10%
Page 16 Subject to technical changes
Safety light grid SLG 422/ 425I-P
6.2 Wiring diagram muting SLG 425IP
Erdung
E1
2 4 1 3 1 8 2 7 3 465
DIA
G IN
DIA
G O
UT
+24V
0V
Nur
für D
iagn
ose
DIA
G IN
DIA
G O
UT
Frei
gabe
WA
Sch
ützk
ontro
lle/E
DM
+24V
0V OS
SD
1
OS
SD
2
K1 K2
Brü
cke
2
Brü
cke
1
Kn1
Kn2
Erdung
E1
2 4 1 3 1 8 2 7 3 465
DIA
G IN
DIA
G O
UT
+24
V D
C
0 V
DC
Nur
für D
iagn
ose
DIA
G IN
DIA
G O
UT
Frei
gabe
WA
Sch
ützk
ontro
lle/E
DM
+24
V D
C
0 V
DC
OS
SD
1
OS
SD
2
K1 K2
Brü
cke
2
Brü
cke
1
Kn1
Kn2
S 1
Erdung
E1
2 4 1 3 1 8 2 7 3 465
DIA
G IN
DIA
G O
UT
+24V
0V
Nur
für D
iagn
ose
DIA
G IN
DIA
G O
UT
Frei
gabe
WA
Sch
ützk
ontro
lle/E
DM
+24V
0V OS
SD
1
OS
SD
2
K1 K2
Brü
cke
2
Brü
cke
1
Kn1
Kn2
Erdung
E1
2 4 1 3 1 8 2 7 3 465
DIA
G IN
DIA
G O
UT
+24
V D
C
0 V
DC
Nur
für D
iagn
ose
DIA
G IN
DIA
G O
UT
Frei
gabe
WA
Sch
ützk
ontro
lle/E
DM
+24
V D
C
0 V
DC
OS
SD
1
OS
SD
2
K1 K2
Brü
cke
2
Brü
cke
1
Kn1
Kn2
S 1
Erdung
E1
2 4 1 3 1 8 2 7 3 465
DIA
G IN
DIA
G O
UT
+24V
0V
Nur
für D
iagn
ose
DIA
G IN
DIA
G O
UT
Frei
gabe
WA
Sch
ützk
ontro
lle/E
DM
+24V
0V OS
SD
1
OS
SD
2
K1 K2
Brü
cke
2
Brü
cke
1
Kn1
Kn2
Earth
E1
1 8 2 7 3 465D
IAG
IN (
grey
)
DIA
G O
UT
(pin
k)
Rel
ease
/Ove
rrid
e (w
hite
)
Con
veyo
r sto
p (r
ed)
+24
V D
C (b
row
n)
0 V
DC
(blu
e)
OS
SD
1 (g
reen
)
OS
SD
2 (y
ello
w)
K1 K2MKS1
Mirror:ULS-P-5002 x 45° deflection
Bridge 1
transmitter- receiver- unitSLG 425IP
1 White
2 Brown
3 Green
4 Yellow
5 Grey
6 Pink
7 Blue
8 Red
The following arrangement shows the sensor connection with the individual connectors:
Muting sensor 1/ machine contact MC, muting sensor 2, muting lamp
6.5 Power supply
The external power supply (+24V/DC) must comply with EN 60204. Furthermore the following requirementsmust be fulfilled:
- A short-term power outage of 20 ms must be bridged by the power supply. - The power supply unit has double insulation between the primary and the secondary side.- The power supply is protected against overload.- The power supply fulfills the regulations of the EEC (industrial environment).- The power supply fulfills the low voltage directive.- The grounded conductor of the power supply unit should be connected to a grounding point PE. - The voltage levels must be within the limits (24VDC +/- 10%).
Subject to technical changes Page 17
Safety light grid SLG 422/ 425I-P
Diagnosis OUT
Power supply
6.3 Connection of cables
InputFreigabe/Override
Designation
SLG 422/425 IPTop view of plug Pin Nr. / Color
Description
Signal
InputEDM/Conveyor stop
24 V DC
Input Diagnostic data
Safety Output 1OSSD 1
Safety Output 2
Power supply
Output Diagnostic data
0 V DC
OSSD 2
Diagnosis IN
6.4 Sensor connection
MS1 / MC MS2 M L
1
258
3 4
67
1
258
3 4
67
7 Testing and Initiation
7.1 Check list
Prior to initiation of SLG 422/425I-P all of the following check list items have to be verified by the responsible person.
Check the wiring before the initiation:
1. The power supply is only connected to SLG 422/ 425 IP .
2. The power supply unit is a 24V/DC power supply unit fulfilling the regulations of the EEC, the Low Voltage Directive and the product standard (IEC 61496).
3. The polarity of the power supply is not reversed.
4. The connection cable is properly connected to the transreceiver.
5. The double insulation is provided between the light grid output and a hazard potential.
6. The outputs OSSD1 and OSSD2 are not shorted to +24 V/DC.
7. The connected switch elements (load) are not shorted to 24V/DC.
Switch the SLG 422/ 425 IP on and test its functionality as follows:
2 seconds after power ON (when the detection zone is unobstructed) the system starts to operateproperly. The outputs are released.
7.2 Troubleshooting
After power ON and release of the detection zone the light grid runs an internal self test. If an erroroccurs, the OSSD OUT (red) LED of the receiver flashes in a special flicker pattern. Every error message is followed by a interval of one second.
LED OSSD OFF Continual flash OSSD OFF and LED Restart 1 x flash2 x flash
3 x flash
4 x flash
5 x flash
6 x flash
7.3 Diagnostic operation
This mode of operation is automatically activated after Power Reset, if the BUS Converter NSR-0801 is connected to the receiver or transmitter. How to connect the BUS converter is described in the NSR-0801 operating manual.When diagnostic operation is active, the OSSD ON and OSSD OFF LEDs of the receiver flash. In diagnostic operation Normal Mode function is not possible. Therefore the output OSSDs are interlocked.The system will automatically switch from diagnostic operation to normal mode function as soon as the BUS converteris no longer integrated and the extension cord of the sensor is connected again.
Page 18 Subject to technical changes
Error
Error configuration data
interruption, i.e. interlock.
Error on the output OSSDs After correction do a power reset
short circuit against +UB and mass.Check output connections; check OSSD for
(Restart interlock, automatic operation)
Error Relay control ONCheck wiring of auxiliary contacts
Error on the sensor of the receiver
ConnectionsError on Relay control OFF
Exchange receiverCheck connection on input Relay control, see
NSR 801
Check configuration defaults with the BUS converter
Check connection of receiver, wiring 1 or Improper wiring
NSR 801
Remedy
wiring 2 must be wired up properly (s. Connections).
Check short circuit against +UB and massCheck connection on input Relay control for
Check configuration defaults with the BUS converter
Safety light grid SLG 422/ 425I-P
Error blanking Receiver detects blanked beams as beams without
8 Technical Characteristics
8.1 Technical Characteristics
IR beamBeam distanceOperating DistanceReaction timePower SupplyPower consumptionIR transmitter
min. specific max.15 V 22,5 V 28,8 V0 V 0 V 2,0 V
0 mA 500 mA1 mA2 μF2 H
min. specific max.2,5 Ω1,0 Ω
Input 17 V 24 V 29 Vrelay monitoring (EMD) 3 mA 5 mA 10 mA
0 V 0 V 2,5 V0 mA 0 mA 2 mA
Input release 17 V 24 V 29 Vrestart interlock 3 mA 5 mA 10 mA
0 V 0 V 2,5 V0 mA 0mA 3 mA50 ms 1000 ms
SLG 422P-E/R0500-02-RFSLG 425IP-E/R0500-02-RFSignal input
Relay monitoring (EMD)Restart interlockStart interlock
OSSD ON after interruption
LEDs
InterfaceDegree of protectionMountingVibration resistanceShock resistanceHousing cross-sectionApproval
Subject to technical changes Page 19
High level input current
muting sensors: 2 pieces M8 3 pin connector
Operation time
High level input voltage (active)High level input current
Safety outputs (OSSD1, OSSD2) ¹) According to IEC 61131-2 ²) In case of error there is a stray current in the OSSD circuit. The subsequent control unit must realise the situation as LOW. A secure SPS must identify the situation.
2 x PNP Semiconductor , short-circuit-proof 0 V to 30 V
Turn on voltage High¹Turn on voltage Low²Switching current Stray current²Load capacityLoad inductive reactance
Start-, restart-interlock + relay monitoring (EMD)
Permittable output resistancebetween OSSD and loadFeed line
Low level input voltage (inactive)Low level input current
High level input voltage (inactive)
Low level input voltage (active)Low level input current
Safety light grid SLG 422/ 425I-P
Type SLG 422-P-02-500-1
IP 67 (IEC 60529)
500 mm
24 V/DC ±10% power supply unit acc. to EN 60204 (power outage > 20 ms)400 mA max. without load + 500 mA (OSSD + signal receipt)
muting lamp: M8 3 pin connector, power consumption max. 500 mA 24V/DC
EN/IEC 61496 –1/-2 Category 4*1 Resolution = Beam distance + beam-diameter 10 mm
50 ms - 1,0 s, monitored50 ms - 500 ms adjustable
10 g, 16 ms, acc. to IEC 60028-2-29Round, diameter 49 mm
OSSD ON, OSSD OFF, restart, signal receipt, blanking, multi-function
Ambient temperature Operation: - 10 to + 50° CStorage: - 25 to + 70° C
10 -55 Hz acc. to IEC 60068-2-6End cap angle bracket, lateral - 2 profile grooves
Diagnosis and function setting
Connection
Start-, restart-interlock + muting
pick time, see chapt. Reaction Time
M12 plug with metal thread, 8-pin
200 ms - Release of the OSSD's after protection field interruption
SLG 425I-P-02-500-1
Wave length 860 nm
10 ms (SLG 422P), 15 ms (SLG 425IP)0,3 - 7,0 m
1 beam (deflection over mirror surface), resolution 500 mm *1
Time min - time max
250 ms - 1500 ms, adjustable
8.2 Dimensioned drawings
8.2.1 Dimensioned drawings standard
SLG422P-E/R0500-02-RF
Type A beam distance ± 1
B Mounting dimens. ± 1
L1± 1
L2± 1
SLG 422P-E/R0500-02-RF 500 681 316 303
Page 20 Subject to technical changes
L2 = Mounting distance (mm) between floor and centre long hole (diagnosis window)
C Total length ± 1
L1 = Mounting distance (mm) between floor and centre long hole (short end cap)
Safety light grid SLG 422/ 425I-P
717
86
L1
L2
AC B
80
97
6,05
48,749,6
8431,5
42
8.2.2 Dimensioned drawings muting
SLG 425IP-E/R0500-02-RF
Type A beam distance ± 1
B Mounting dimens. ± 1
L1± 1
L2± 1
SLG 425IP-E/R0500-02-RF 500 745 316 239
Subject to technical changes Page 21
L1 = Mounting distance (mm) between floor and centre long hole (short end cap)L2 = Mounting distance (mm) between floor and centre long hole (diagnosis window)
C Total length ± 1
Safety light grid SLG 422/ 425I-P
781
150
L1
L2
AC B
80
161
6,05
48,749,6
8431,5
42
8.2.3 Drawing ULS-P-0501
Art.-No.: Type A Mirror height
B Mounting
CTotal length
1207548 ULS-P-0501 606 648 690All data in mm, tolerance +/- 1,0 mm
8.3 Mounting accessories
8.3.1 Mounting set MS-1030
The mounting bracket is composed of 4 steel angles and 16 fastening screws.
Page 22 Subject to technical changes
Safety light grid SLG 422/ 425I-P
40
52
32
20
6,5
42
14,5
18,9
40
52
32
20
6,5
42
14,5
18,9
8.3.2 Middle mounting bracket MS-1051
Assembly kit consisting of 2 steel angles, 4 screws and 4 sliding blocks for centered mounting.
8.4 Response time (reaction time)
Type Beams [number]
Beam distance[mm]
SLG 422P-E/R0500-02-RF 2 500SLG 425IP-E/R0500-02-RF 2 500
8.5 Type
Type Beams [number]
Beam distance[mm]
Distance [m]
Weight[kg]
SLG 422P-E/R0500-02-RF 2 500 0,3 - 7,0 1,3SLG 425IP-E/R0500-02-RF 2 500 0,3 - 7,0 1,4
8.5.1 Order numbers
R = RestartF = Feedback
number of beams
protective height in mm
E = Emitter-R = Receiver- unit
SLG 422/425IP = Safety Light Grid
Subject to technical changes Page 23
Safety light grid SLG 422/ 425I-P
1015
Following table shows the response time of the safety light grid SLG 422/ 425I-P.
Middle mounting is an alternative fastening method at the side of the profile. A combination of the middle mounting brackets is recommendable for higher mechanical loads (e.g. vibration).
Reaction time [ms]
40
20
20
42
14,5
18,9
38 32
4,5
R2
40
20
42
14,5
18,9
38 32
4,5
R2
40
20
42
14,5
18,9
38 32
4,5
R2
40
20
20
42
14,5
18,9
38 32
4,5
R2
40
20
42
14,5
18,9
38 32
4,5
R2
SLG 425I XX XXE/R XXXXSLG 425I XX XXE/R XXXX
9.1 Accessories included in the delivery package
Mounting set MS-1030Consisting of 2 steel angles and 8screws (size 10) for fastening on the 2 end caps.
Documentation Operating manual, format A4
9.2 Optional accessories
Middle mounting bracket MS-1051 Consisting of 2 steel angles,
4 screws (size 3) and 4 sliding blocks
Extension cord for SLG 422/ 425I-P
Art. Number Designation Length1207728 KA-0904 5 m1207729 KA-0905 10 m1207730 KA-0908 20 m
(special length upon request)
Reflection mirror Art.-No.ULS-P-0501 1207548
The compact design of the ULS-P-0501 mounted on an assembly stand MST offers stability for industrial applications.A mounting set includes to the delivery.
BUS-Converter NSR-0801 Converter for parametrization and diagnosis.
For detailed information please refer to the operatingmanual of NSR-0801.Delivery package: Extension cable integrated, PC
(LxWxH 122 x 60 x 35mm) measured without cables.
Page 24 Subject to technical changes
Software and USB 2.0 connection
DescriptionM12 x 1, 8 pin straight
SLG 422/ 425I-P.
Safety light grid SLG 422/ 425I-P
9 Accessories
The reflection mirror ULS-P-0501 is ideal to divert the infrared light of a
M12 x 1, 8 pin straightM12 x 1, 8 pin straight
Type Height of mirror in mmULS-P-0501
The light is diverted twice over a reflection surface in an angle of 45 degrees.When light is reflected over a mirror surface it loses strength.
606
Note:
1. For safety reasons we recommend to store all inspection results.2. The person conducting an inspection must be familiar with the functions of ALFA 4 and the machine.3. If installer, design technician and user are different people make sure to provide sufficient information to enable the user to carry out the maintenance.
10.1 Inspection according to machine maintenance
3. The safety distance of the application is bigger than the calculated distance.4. The optical cover is neither scratched nor dirty.Turn the machine on and check whether the hazardous movement stops under the following conditions:5. Dangerous machine parts move while the protective zone is uninterrupted.
7. Hazardous machine movement continues after switching off the power supply of SLG 422/ 425 IP.
10.2 Inspection every 6 months
Check the following items in intervals of 6 months or as soon as machine settings have been changed:
2. The machine or connection modification has no effect on the control system. 3. The outputs of SLG 422/ 425 IP are properly wired to the machine.4. The total response time of the machine is lower than the calculated response time.5. Cables and plugs of SLG 422/ 425 IP are in flawless condition.6. The brackets, end caps and cables are secured tightly.
10.3 Cleaning
If the optical cover of the sensors is extremely dirty the outputs OSSD of SLG 422/ 425 IP may be switched off. Clean it with a clean soft cloth without applying pressure. Do not use aggressive, scouring or scratching detergents which might attack the surface.
11 Contact
Support / Sales: Please contact your countries local Schmersal agency.Agencies worldwide are listed at www.schmersal.com website.
Service Repairs: Safety Control GmbHAm Industriepark 1184453 Mühldorf
Tel.: +49 (0) 8631-18796-0Fax: +49 (0) 8631-18796-1
Please see www.schmersal.com for more detailed information about our products.
Subject to technical changes Page 25
1. Approaching the protective zone is only possible across the protection zone of the SLG 422/ 425 IP.
1. Protective zone can only be reached by interrupting a light beam (machine stops).
Never use ALFA 4 before the inspection have been completed as described in the paragraphs below. Improper inspection may lead to serious injuries or death.
10 Safety instructions - Maintenance
! Attention
2. No operators are within the protective zone while dangerous machine parts are in action.
6. Dangerous machine movement stops immediately if one or more beams are interrupted.
Safety light grid SLG 422/ 425I-P
12 Annex
We
declare that the safety components of
Model Safety-Light-Grid Category 4
Type SLG 422P / 425 IP
EN 61496-1:2004 Electro-sensitive protective equipment - General requirements and tests (IEC 44/303)
CLC/TS 61496-2:2006 Electro-sensitive protective equipment - Special requirements and test equipment (IEC 44/316)
EN ISO 13849-1:2006; PL e Safety related parts of control systems - Part 1: General principles for designEN 62061:2005, SIL 3 Safety of machinery – Functional safety of safety-related electrical, electronic
and programmable electronic control systems
For the safety components, listed in Appendix IV B1 of the EU Directive 98/37/EC, the following test center issued an EU examination certificate.
Mühldorf, 19.12.2008Christian Spranger Klaus Schuster Geschäftsführer Manager
In agreement with the EEC guideline 89/336/EWG the CE marking will be attached. This explanation certifies the agreement with the guidelines mentioned, but contains no warranty of characteristicsThe provided product documentation (safety references) has to be considered absolutely.
Page 26 Subject to technical changes
Version 1.4
Am TÜV 1D - 30519 Hannover
Zertifizierungsstelle für Produktsicherheit
These safety components refer to an examination certificate no. 44 205 09 555018 001
TÜV NORD CERT GmbH & Co. KG
as described in the attached documentation, is according to EU-Machinery directive 98/37,
D - 84453 Mühldorf
Safety Control GmbHAm Industriepark 33
CE Declaration of Conformity
Safety light grid SLG 422/ 425I-P
and the technical rules