Safety Data Sheet Regia Reagent Page 5 Explosion: Above flash point, vapor-air mixtures are...
Transcript of Safety Data Sheet Regia Reagent Page 5 Explosion: Above flash point, vapor-air mixtures are...
Copyright 2015-2018 © · All rights reserved PACE Technologies · 3601 E. 34th St · Tucson, AZ 85713 USA
Telephone +1 520-882-6598 · FAX +1 520-882-6599 · [email protected]
Emergency phone number (CHEMTREC 800-424-9300)
Safety Data Sheet Aqua Regia Reagent
Page 1
Section 1: Identification
MANUFACTURER: PACE Technologies
3601 E. 34th St.
Tucson, AZ 85713
INFORMATION PHONE: 520-882-6598
EMERGENCY PHONE: CHEMTREC 800-424-9300 (US) Day or night
Customer No. 16568
TRADE NAME: Aqua Regia Reagent
CHEMICAL FAMILY: Corrosive Liquids, Acidic, Inorganic n.o.s. (Hydrochloric, Nitric Acid)
HMIS RATING: HEALTH: 3 FLAMMABILITY: 1 REACTIVITY: 1
HAZARD RATING:
LEAST: 0 SLIGHT: 1 MODERATE: 2 HIGH: 3 EXTREME: 4
Section 2: Hazard(s) Identification
GHS Classification
in accordance with
29 CFR 1910
(OSHA HCS)
Acute toxicity, Oral (Category 4), H302
Acute toxicity, Dermal (Category 4), H312
Skin irritation (Category 2), H315
Serious eye damage (Category 1), H318
Specific target organ toxicity - single exposure (Category 1), H370
Acute aquatic toxicity (Category 1), H400
Acute aquatic toxicity (Category 2), H401
Chronic aquatic toxicity (Category 2), H411
PICTOGRAM(s):
SIGNAL WORD: Danger
HAZARD
STATEMENTS: Hazard Statement(s):
H302- Harmful if swallowed
H312- Harmful in contact with skin
H315- Causes skin irritation
H318 - Causes serious eye damage
H370- Causes damage to organs
Copyright 2015-2018 © · All rights reserved PACE Technologies · 3601 E. 34th St · Tucson, AZ 85713 USA
Telephone +1 520-882-6598 · FAX +1 520-882-6599 · [email protected]
Emergency phone number (CHEMTREC 800-424-9300)
Safety Data Sheet Aqua Regia Reagent
Page 2
H401- Toxic to aquatic life
H411- Toxic to aquatic life with long lasting effects
PRECAUTIONARY
STATEMENTS: Precautionary Statement(s):
Preventions:
P210-Keep away from heat/sparks/open flames/hot surfaces. — No smoking.
P233- Keep container tightly closed.
P240- Ground/bond container and receiving equipment.
P241- Use explosion-proof electrical/ventilating/lighting/equipment.
P242- Use only non-sparking tools.
P243- Take precautionary measures against static discharge.
P260- Do not breathe dust/fume/gas/mist/vapors/spray.
P264- Wash skin thoroughly after handling.
P270- Do not eat, drink or smoke when using this product.
P273- Avoid release to the environment.
P280- Wear protective gloves/protective clothing/eye protection/face protection.
Response:
P301+312- IF SWALLOWED: call a POISON CENTER or doctor/physician IF you feel
unwell.
P302+352- IF ON SKIN: wash with plenty of soap and water.
P303+ P361+P353- IF ON SKIN (or hair): Remove/Take off Immediately all contaminated
clothing. Rinse SKIN with water/shower.
P305+P351+P338- IF IN EYES: Rinse cautiously with water for several minutes. Remove
contact lenses, if present and easy to do. Continue rinsing.
P307+P311- IF exposed: call a POISON CENTER or doctor/physician.
P310- Immediately call a POISON CENTER or doctor/physician.
P312- Call a POISON CENTER or doctor/physician if you feel unwell.
P321- Specific treatment (see Section 4 SDS).
P322- Specific measures (see Section 4 SDS).
P330- Rinse mouth.
P363- Wash contaminated clothing before reuse.
P370+P378- In case of fire: Use dry chemical, CO2 or appropriate foam for extinction.
P391- Collect spillage. Hazardous to the aquatic environment
Storage: P403+P235- Store in a well-ventilated place. Keep cool.
P405- Store locked up.
Disposal: P501- Dispose of contents/container to Federal, State and Local Regulations.
Emergency Overview --------------------------
POISON! DANGER! MAY BE FATAL IF SWALLOWED. HARMFUL IF INHALED OR
ABSORBED THROUGH SKIN. VAPOR HARMFUL. FLAMMABLE! AFFECTS
CENTRAL NERVOUS SYSTEM. MAY CAUSE BLINDNESS. CANNOT BE MADE
NONPOISONOUS. CAUSES IRRITATION TO SKIN, EYES AND RESPIRATORY
TRACT. MAY AFFECT LIVER, BLOOD, REPRODUCTIVE SYSTEM.
SAF-T-DATA(tm) Ratings (Provided here for your convenience)
Copyright 2015-2018 © · All rights reserved PACE Technologies · 3601 E. 34th St · Tucson, AZ 85713 USA
Telephone +1 520-882-6598 · FAX +1 520-882-6599 · [email protected]
Emergency phone number (CHEMTREC 800-424-9300)
Safety Data Sheet Aqua Regia Reagent
Page 3
-----------------------------------------------------------------------------------------------------------
Health Rating: 3 - Severe (Poison)
Flammability Rating: 1 - Slight
Reactivity Rating: 1 - Slight
Contact Rating: 3 - Severe (Life and Corrosive)
Lab Protective Equip: GOGGLES & SHIELD; LAB COAT & APRON; VENT HOOD;
PROPER GLOVES; CLASS B EXTINGUISHER
Storage Color Code: White (Corrosive)
-----------------------------------------------------------------------------------------------------------
Potential Health Effects ----------------------------------
Inhalation: Copper Chloride - Causes irritation to respiratory tract, symptoms may include coughing, sore
throat, and shortness of breath. May result in ulceration and perforation of respiratory tract.
When heated, this compound may give off copper fume, which can cause symptoms similar to
the common cold, including chills and stuffiness of the head.
Ingestion: Copper Chloride - May cause burning pain in the mouth, esophagus, and stomach. Hemorrhagic
gastritis, nausea, vomiting, abdominal pain, metallic taste, and diarrhea may occur. If vomiting
does not occur immediately systemic copper poisoning may occur. Symptoms may include
capillary damage, headache, cold sweat, weak pulse, kidney and liver damage, central nervous
excitation followed by depression, jaundice, convulsions, blood effects, paralysis and coma.
Death may occur from shock or renal failure.
Copper Chloride - Causes irritation, redness, and pain. Some individuals may develop copper
allergies.
IF SWALLOWED: rinse mouth. Do NOT induce vomiting. Dilute with water or milk. Vomiting
may occur spontaneously but do not induce. Call a physician immediately.
Eye Contact: Copper Chloride - Causes severe irritation with symptoms of redness, pain, blurred vision,
discoloration, and possible eye damage.
Chronic Exposure: Copper Chloride - Prolonged or repeated skin exposure may cause dermatitis. Prolonged or
repeated exposure to dusts of copper salts may cause discoloration of the skin or hair, blood and
liver damage, ulceration and perforation of the nasal septum, runny nose, metallic taste, and
atrophic changes and irritation of the mucous membranes.
CONTACT: Skin contact causes burns, blistering, local necrosis, and membrane ulceration.
Burns may be 2nd or 3rd degree
Copyright 2015-2018 © · All rights reserved PACE Technologies · 3601 E. 34th St · Tucson, AZ 85713 USA
Telephone +1 520-882-6598 · FAX +1 520-882-6599 · [email protected]
Emergency phone number (CHEMTREC 800-424-9300)
Safety Data Sheet Aqua Regia Reagent
Page 4
Aggravation of Pre-existing Conditions: Copper Chloride - Persons with pre-existing skin disorders, impaired liver, kidney, or pulmonary
function, glucose 6-phosphate-dehydrogenase deficiency, or pre-existing Wilson's disease may
be more susceptible to the effects of this material.
Section 3: Composition/Information on Ingredients
HAZARD INGREDIENTS
CHEMICAL CAS NUMBER % PRESENT Hazardous
Water 7732-18-5 40-60% No
Copper (II) chloride 7447-39-4 10-20% Yes
Hydrogen Chloride 7647-01-0 5-15% Yes
Nitric Acid 7697-37-2 10 - 15% Yes
Section 4: First-Aid Measures
Inhalation: Remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give
oxygen. Call a physician.
Ingestion: Induce vomiting immediately as directed by medical personnel. Never give anything by mouth to
an unconscious person.
Skin Contact: In case of contact, wipe off excess material from skin then immediately flush skin with plenty of
water for at least 15 minutes. Remove contaminated clothing and shoes. Wash clothing before
reuse. Call a physician.
Eye Contact: Immediately flush eyes with plenty of water for at least 15 minutes, lifting lower and upper
eyelids occasionally. Get medical attention immediately.
Section 5: Fire-Fighting Measures
Fire: Autoignition temperature: 422C (792F)
Copyright 2015-2018 © · All rights reserved PACE Technologies · 3601 E. 34th St · Tucson, AZ 85713 USA
Telephone +1 520-882-6598 · FAX +1 520-882-6599 · [email protected]
Emergency phone number (CHEMTREC 800-424-9300)
Safety Data Sheet Aqua Regia Reagent
Page 5
Explosion: Above flash point, vapor-air mixtures are explosive within flammable limits noted above. Vapors
can flow along surfaces to distant ignition source and flash back. Sealed containers may rupture
when heated. Sensitive to static discharge.
Fire Extinguishing Media: Water spray, dry chemical, alcohol foam, or carbon dioxide. Water may be ineffective.
Special Information: In the event of a fire, wear full protective clothing and NIOSH-approved self-contained breathing
apparatus with full facepiece operated in the pressure demand or other positive pressure mode.
Water spray can be used to extinguish fires and cool fire-exposed containers. Water may be used
to flush spills away from exposures and to dilute spills to non-flammable mixtures.
Section 6: Accidental Release Measures
Ventilate area of leak or spill. Remove all sources of ignition. Wear appropriate personal
protective equipment as specified in Section 8. Isolate hazard area. Keep unnecessary and
unprotected personnel from entering. Contain and recover liquid when possible. Use non-
sparking tools and equipment. Collect liquid in an appropriate container or absorb with an inert
material (e. g., vermiculite, dry sand, earth), and place in a chemical waste container. Do not use
combustible materials, such as saw dust. Do not flush to sewer! US Regulations (CERCLA)
require reporting spills and releases to soil, water and air in excess of reportable quantities. The
toll free number for the US Coast Guard National Response Center is (800) 424-8802.
Section 7: Handling and Storage
Protect against physical damage. Store in a cool, dry well-ventilated location, away from any
area where the fire hazard may be acute. Outside or detached storage is preferred. Separate from
incompatibles. Containers should be bonded and grounded for transfers to avoid static sparks.
Storage and use areas should be No Smoking areas. Use non-sparking type tools and equipment,
including explosion proof ventilation. Containers of this material may be hazardous when empty
since they retain product residues (vapors, liquid); observe all warnings and precautions listed for
the product.
Copyright 2015-2018 © · All rights reserved PACE Technologies · 3601 E. 34th St · Tucson, AZ 85713 USA
Telephone +1 520-882-6598 · FAX +1 520-882-6599 · [email protected]
Emergency phone number (CHEMTREC 800-424-9300)
Safety Data Sheet Aqua Regia Reagent
Page 6
Section 8: Exposure Controls/ Personal Protection
Chemical Name Limit Type Country Exposure Limit Information Source
Cupric Chloride
Dihydrate (10125-
13-0)
TLV-TWA USA 1 mg/m³ TWA (dust
and mist, as Cu)
ACGIH - Threshold
Limit Values - Time
Weighted Averages
(TLV-TWA)
Hydrochloric Acid
(7647-01-0)
TLV-Ceiling USA 2 ppm Ceiling ACGIH - Threshold
Limit Values -
Ceilings (TLV-C)
Hydrochloric Acid
(7647-01-0)
PEL-Ceiling USA 5 ppm Ceiling
7 mg/m³ Ceiling
U.S. - OSHA - Final
PELs - Ceiling
Limits
Nitric Acid (7697-
37-2)
TWA USA 2 ppm TWA
5 mg/m³ TWA
U.S. - OSHA - Final
PELs - Time
Weighted Averages
(TWAs)
Nitric Acid (7697-
37-2)
TLV-STEL USA 4 ppm STEL ACGIH - Threshold
Limit Values - Short
Term Exposure
Limits (TLV-STEL)
Nitric Acid (7697-
37-2)
TLV-TWA USA 2 ppm TWA ACGIH - Threshold
Limit Values - Time
Weighted Averages
(TLV-TWA
Ventilation System: A system of local and/or general exhaust is recommended to keep employee exposures below the
Airborne Exposure Limits. Local exhaust ventilation is generally preferred because it can control
the emissions of the contaminant at its source, preventing dispersion of it into the general work
area. Please refer to the ACGIH document, Industrial Ventilation, A Manual of Recommended
Practices, most recent edition, for details.
Personal Respirators (NIOSH Approved): If the exposure limit is exceeded and engineering controls are not feasible, a half facepiece
particulate respirator (NIOSH type N95 or better filters) may be worn for up to ten times the
exposure limit or the maximum use concentration specified by the appropriate regulatory agency
or respirator supplier, whichever is lowest.. A full-face piece particulate respirator (NIOSH type
N100 filters) may be worn up to 50 times the exposure limit, or the maximum use concentration
specified by the appropriate regulatory agency, or respirator supplier, whichever is lowest. If oil
particles (e.g. lubricants, cutting fluids, glycerine, etc.) are present, use a NIOSH type R or P
Copyright 2015-2018 © · All rights reserved PACE Technologies · 3601 E. 34th St · Tucson, AZ 85713 USA
Telephone +1 520-882-6598 · FAX +1 520-882-6599 · [email protected]
Emergency phone number (CHEMTREC 800-424-9300)
Safety Data Sheet Aqua Regia Reagent
Page 7
filter. For emergencies or instances where the exposure levels are not known, use a full-facepiece
positive-pressure, air-supplied respirator. WARNING: Air-purifying respirators do not protect
workers in oxygen-deficient atmospheres.
Skin Protection: Wear impervious protective clothing, including boots, gloves, lab coat, apron or coveralls, as
appropriate, to prevent skin contact.
Eye Protection: Use chemical safety goggles and/or full face shield where dusting or splashing of solutions is
possible. Maintain eye wash fountain and quick-drench facilities in work area.
Section 9: Physical and Chemical Properties
Appearance: Light blue-green clear color.
Odor: Mild pleasant whiskey-like odor with slight odor of hydrochloric acid.
Solubility: Miscible in water.
Specific Gravity: 0.8-0.9
pH: No information found.
% Volatiles by volume @ 21C (70F): >90%
Boiling Point: Data Not Available
Melting Point: -114C (-173F)
Vapor Density (Air=1): Data Not Available
Vapor Pressure (mm Hg): Data Not Available
Evaporation Rate (BuAc=1): ca. 1.4 (CCl4=1) (ethanol)
Section 10: Stability and Reactivity
Stability: Stable under ordinary conditions of use and storage.
Hazardous Decomposition Products: Oxides of the contained metal and halogen, possibly also free, or ionic halogen.
Copyright 2015-2018 © · All rights reserved PACE Technologies · 3601 E. 34th St · Tucson, AZ 85713 USA
Telephone +1 520-882-6598 · FAX +1 520-882-6599 · [email protected]
Emergency phone number (CHEMTREC 800-424-9300)
Safety Data Sheet Aqua Regia Reagent
Page 8
Hazardous Polymerization: Will not occur.
Incompatibilities: Copper Chloride-Potassium, sodium, hydrazine, nitromethane, aluminum, strong oxidizers,
acetylene, and sodium hypobromite. Corrosive to aluminum; on contact with acids it may release
toxic chloride fumes.
Conditions to Avoid: Product is used for etching metals, take precaution when using in conjunction with
incompatibles.
Avoid heat, flames, ignition sources.
Section 11: Toxicological Information
Acute Toxicity - Oral Exposure:
Fatal if swallowed. Wash arms, hands and face thoroughly after handling. Do not eat, drink or
smoke when using this product. IF SWALLOWED: Immediately call a POISON CENTER or
physician. Specific treatment (Wash areas of contact with water immediately). Rinse mouth.
Store locked up. Dispose of contents in accordance with local, state, federal and international
regulations.
Acute Toxicity - Dermal Exposure:
Harmful in contact with skin. Wear protective gloves and eye protection. IF ON SKIN: Wash
with plenty of soap and water. Call a POISON CENTER or physician if you feel unwell. Specific
treatment (Wash areas of contact with water immediately). Take off contaminated clothing and
wash it before reuse. Dispose of contents in accordance with local, state, federal and
international regulations.
Acute Toxicity - Inhalation Exposure:
Fatal if inhaled. Do not breathe fumes, mist, vapors, or spray. Use only outdoors or in a well-
ventilated area. In case of inadequate ventilation wear respiratory protection. IF INHALED:
Remove person to fresh air and keep comfortable for breathing. Immediately call a POISON
CENTER or physician. Specific treatment is urgent (Wash areas of contact with water
immediately). Store in a well-ventilated place. Keep container tightly closed. Store locked up.
Dispose of contents in accordance with local, state, federal and international regulations.
Acute Toxicity - Other Information:
LD50, Oral, Rabbit (Hydrochloric Acid) 900 mg/kg; Details of toxic effects not reported other
than lethal dose value. LCLo, inhalation, human: 3000 ppm/5 minutes: No toxic effects noted.
LDLo, Oral, Human: 430 mg/kg (Nitric Acid), details of toxic effects not reported other than
lethal dose value.
Copyright 2015-2018 © · All rights reserved PACE Technologies · 3601 E. 34th St · Tucson, AZ 85713 USA
Telephone +1 520-882-6598 · FAX +1 520-882-6599 · [email protected]
Emergency phone number (CHEMTREC 800-424-9300)
Safety Data Sheet Aqua Regia Reagent
Page 9
Skin Corrosion and Irritation:
Causes severe skin burns and eye damage. Do not breathe fumes, mist, vapors, or spray. Wash
arms, hands and face thoroughly after handling. Wear protective gloves and eye protection. IF
SWALLOWED: rinse mouth. Do NOT induce vomiting. IF ON SKIN (or hair): Take off
immediately all contaminated clothing. Rinse skin with water. Wash contaminated clothing
before reuse. IF INHALED: Remove person to fresh air and keep comfortable for breathing.
Immediately call a POISON CENTER or physician. Specific treatment (Wash areas of contact
with water immediately). IF IN EYES: Rinse cautiously with water for several minutes. Remove
contact lenses, if present and easy to do. Continue rinsing. Store locked up. Dispose of contents
in accordance with local, state, federal and international regulations.
Serious Eye Damage and Irritation:
Causes serious eye damage. Wear protective gloves and eye protection. IF IN EYES: Rinse
cautiously with water for several minutes. Remove contact lenses, if present and easy to do.
Continue rinsing. Immediately call a POISON CENTER or physician.
Respiratory Sensitization:
May cause allergy or asthma symptoms or breathing difficulties if inhaled. Avoid breathing
fumes, mist, vapors, or spray. In case of inadequate ventilation wear respiratory protection. IF
INHALED: If breathing is difficult, remove person to fresh air and keep comfortable for
breathing. If experiencing respiratory symptoms: Call a POISON CENTER or physician.
Dispose of contents in accordance with local, state, federal and international regulations.
Skin Sensitization:
May cause an allergic skin reaction. Avoid breathing fumes, mist, vapors, or spray.
Contaminated work clothing must not be allowed out of the workplace. Wear protective gloves
and eye protection. IF ON SKIN: Wash with plenty of soap and water. If skin irritation occurs:
Get medical attention. Specific treatment (Wash areas of contact with water immediately). Wash
contaminated clothing before reuse. Dispose of contents in accordance with local, state, federal
and international regulations.
Germ Cell Mutagenicity:
Not applicable.
Carcinogenicity:
Not applicable.
Reproductive Toxicity:
Suspected of damaging fertility or the unborn child. Obtain special instructions before use. Do
not handle until all safety precautions have been read and understood. Wear protective gloves
and eye protection. IF exposed or concerned: Get medical attention. Store locked up. Dispose of
contents in accordance with local, state, federal and international regulations.
Copyright 2015-2018 © · All rights reserved PACE Technologies · 3601 E. 34th St · Tucson, AZ 85713 USA
Telephone +1 520-882-6598 · FAX +1 520-882-6599 · [email protected]
Emergency phone number (CHEMTREC 800-424-9300)
Safety Data Sheet Aqua Regia Reagent
Page 10
Specific Target Organ Toxicity from Single Exposure:
Causes damage to organs. Do not breathe fumes, mist, vapors, or spray. Wash arms, hands and
face thoroughly after handling. Do not eat, drink or smoke when using this product. IF exposed:
Call a POISON CENTER or physician. Specific treatment (Wash areas of contact with water
immediately). Store locked up. Dispose of contents in accordance with local, state, federal and
international regulations.
Specific Target Organ Toxicity from Repeated Exposure:
Causes damage to organs through prolonged or repeated exposure. Do not breathe fumes, mist,
vapors, or spray. Wash arms, hands and face thoroughly after handling. Do not eat, drink or
smoke when using this product. Get medical attention if you feel unwell. Dispose of contents in
accordance with local, state, federal and international regulations.
Aspiration Hazard:
May be fatal if swallowed and enters airways. IF SWALLOWED: Immediately call a POISON
CENTER or physician. Do NOT induce vomiting. Store locked up. Dispose of contents in
accordance with local, state, federal and international regulations.
Additional Toxicology Information:
Data not available
Section 12: Ecological Information
Environmental Fate: Very toxic to aquatic life. Avoid release to the environment. Dispose of contents in accordance
with local, state, federal and international regulations.Toxic to aquatic life. Avoid release to the
environment. Dispose of contents in accordance with local, state, federal and international
regulations.
Following data for copper chloride: When released into the soil, this material is not expected to
biodegrade. When released into the soil, this material may leach into groundwater. When
released into water, this material is not expected to biodegrade. When released into water, this
material is not expected to evaporate significantly. This material is expected to significantly
bioaccumulate. This material has an experimentally-determined bioconcentration factor (BCF) of
greater than 100. Bioaccumulation data for copper.
Environmental Toxicity: Following data for copper chloride: This material is not expected to be toxic to aquatic life. The
LC50/96-hour values for fish are over 100 mg/l.
Copyright 2015-2018 © · All rights reserved PACE Technologies · 3601 E. 34th St · Tucson, AZ 85713 USA
Telephone +1 520-882-6598 · FAX +1 520-882-6599 · [email protected]
Emergency phone number (CHEMTREC 800-424-9300)
Safety Data Sheet Aqua Regia Reagent
Page 11
Section 13: Disposal Considerations
Whatever cannot be saved for recovery or recycling should be handled as hazardous waste and
sent to a RCRA approved incinerator or disposed in a RCRA approved waste facility.
Processing, use or contamination of this product may change the waste management options.
State and local disposal regulations may differ from federal disposal regulations. Dispose of
container and unused contents in accordance with federal, state and local requirements.
Section 14: Transportation Information
Domestic (Land, D.O.T.) -----------------------
Proper Shipping Name: Corrosive Liquids, Acidic, Inorganic n.o.s. (Hydrochloric, Nitric Acid)
Hazard Class: 8
UN/NA: UN 3264
Packing Group: II
Label Codes: 8
NMFC: 45615-11
Shipping Class CL125
International (Air, I.C.A.O.) -----------------------------
Proper Shipping Name: Corrosive Liquid, Acidic, Inorganic n.o.s. (Hydrochloric, Nitric Acid)
Hazard Class: 8
UN/NA: UN 3264
Packing Group: II
Label Codes: 8
Section 15: Regulatory Information
--------\Chemical Inventory Status - Part 1\-------------------------------
Ingredient TSCA EC Japan Australia
----------------------------------------------- ---- --- ----- -------
Copper Chloride (7447-39-4) Yes Yes Yes Yes
Hydrogen Chloride (7647-01-0) Yes Yes Yes Yes
Water (7732-18-5) Yes Yes Yes Yes
Nitric Acid (7697-37-2) Yes Yes Yes Yes
--------\Chemical Inventory Status - Part 2\------------------------------
Copyright 2015-2018 © · All rights reserved PACE Technologies · 3601 E. 34th St · Tucson, AZ 85713 USA
Telephone +1 520-882-6598 · FAX +1 520-882-6599 · [email protected]
Emergency phone number (CHEMTREC 800-424-9300)
Safety Data Sheet Aqua Regia Reagent
Page 12
--Canada--
Ingredient Korea DSL NDSL Phil.
----------------------------------------------- ----- --- ---- -----
Copper Chloride (7447-39-4) Yes Yes No Yes
Hydrogen Chloride (7647-01-0) Yes Yes No Yes
Water (7732-18-5) Yes Yes No Yes
Nitric Acid (7697-37-2) Yes Yes No Yes
--------\Federal, State & International Regulations - Part 1\-------------
-SARA 302- ------SARA 313------
Ingredient RQ TPQ List Chemical Catg.
-------------------------------------- --- ----- ---- --------------
Copper Chloride (7447-39-4) No No No Copper compo
Hydrogen Chloride (7647-01-0) 5000 500* Yes No
Water (7732-18-5) No No No No
Nitric Acid (7697-37-2) 500 500 Yes No
-----\Federal, State & International Regulations - Part 2\----------------
-RCRA- -TSCA-
Ingredient CERCLA 261.33 8(d)
----------------------------------------- ------ ------ ------
Copper Chloride (7447-39-4) 10 No No
Hydrogen Chloride (7647-01-0) 5000 No No
Water (7732-18-5) No No No
Nitric Acid (7697-37-2) 500 No No
Chemical Weapons Convention: No TSCA 12(b): No CDTA: Yes
SARA 311/312: Acute: Yes Chronic: Yes Fire: Yes Pressure: No
Reactivity: No (Mixture / Liquid)
Australian Hazchem Code: 2[S]E ,. 2Z
Poison Schedule: S5
WHMIS: This MSDS has been prepared according to the hazard criteria of the Controlled Products
Regulations (CPR) and the MSDS contains all of the information required by the CPR.
Copyright 2015-2018 © · All rights reserved PACE Technologies · 3601 E. 34th St · Tucson, AZ 85713 USA
Telephone +1 520-882-6598 · FAX +1 520-882-6599 · [email protected]
Emergency phone number (CHEMTREC 800-424-9300)
Safety Data Sheet Aqua Regia Reagent
Page 13
Section 16: Other Information
16.1 NFPA 704
Top, Flammability: 0 – Minimal Hazard
Left, Health Hazard: 3 – Severe Hazard
Right, Reactivity: 1 – Slight Hazard
Bottom, Special Notice: COR – Corrosive
Product Use: Laboratory Reagent.
Disclaimer:
PACE Technologies, Inc. provides the information contained herein in good faith but
makes no representation as to its comprehensiveness or accuracy. This document is
intended only as a guide to the appropriate precautionary handling of the material by a
properly trained person using this product. Individuals receiving the information must
exercise their independent judgment in determining its appropriateness for a particular
purpose. PACE TECHNOLOGIES, INC. MAKES NO REPRESENTATIONS OR
WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING WITHOUT
LIMITATION ANY WARRANTIES OF MERCHANTABILITY, FITNESS FOR A
PARTICULAR PURPOSE WITH RESPECT TO THE INFORMATION SET FORTH
HEREIN OR THE PRODUCT TO WHICH THE INFORMATION REFERS.
ACCORDINGLY, PACE TECHNOLOGIES, INC. WILL NOT BE RESPONSIBLE FOR
DAMAGES RESULTING FROM USE OF OR RELIANCE UPON THIS
INFORMATION. DATE PREPARED: 3/20/2018 AG
DATE REVISED: 6/7/2018 AG
0
3 1
COR