Safe Drinking Water Act Phase II & V Sampling Procedures: Diquat - Method 549.1.

42
Safe Drinking Water Act Safe Drinking Water Act Phase II & V Sampling Phase II & V Sampling Procedures: Procedures: Diquat - Method 549.1 Diquat - Method 549.1

Transcript of Safe Drinking Water Act Phase II & V Sampling Procedures: Diquat - Method 549.1.

Page 1: Safe Drinking Water Act Phase II & V Sampling Procedures: Diquat - Method 549.1.

Safe Drinking Water Act Safe Drinking Water Act Phase II & V Sampling Phase II & V Sampling

Procedures:Procedures:Diquat - Method 549.1Diquat - Method 549.1

Page 2: Safe Drinking Water Act Phase II & V Sampling Procedures: Diquat - Method 549.1.

The purpose of these slides is to demonstrate The purpose of these slides is to demonstrate recommended sampling techniques. This recommended sampling techniques. This presentation includes:presentation includes: supplies neededsupplies needed sample tap selectionsample tap selection collection; and collection; and shipping. shipping.

SOC – Diquat Sampling ProceduresSOC – Diquat Sampling Procedures

Page 3: Safe Drinking Water Act Phase II & V Sampling Procedures: Diquat - Method 549.1.

We know and recognize that there are numerous We know and recognize that there are numerous techniques and methods for collecting drinking techniques and methods for collecting drinking water samples. The idea of this presentation is to water samples. The idea of this presentation is to demonstrate the general method used while demonstrate the general method used while providing some helpful suggestions for sample providing some helpful suggestions for sample collection, whether you are an owner, operator, or collection, whether you are an owner, operator, or trainee. This presentation is in no way to be trainee. This presentation is in no way to be considered a substitute for the federal Safe considered a substitute for the federal Safe Drinking Water Act and amendments.Drinking Water Act and amendments.

SOC – Diquat Sampling ProceduresSOC – Diquat Sampling Procedures

Page 4: Safe Drinking Water Act Phase II & V Sampling Procedures: Diquat - Method 549.1.

What are SOCs and why do we sample What are SOCs and why do we sample

for them?for them?

Since the Safe Drinking Water Act Amendments of 1986, The US Environmental Protection

Agency has established Maximum Contaminant Levels (MCL) for polychlorinated biphenyls

(PCBs), 23 pesticides, and six other synthetic organic chemicals.

Page 5: Safe Drinking Water Act Phase II & V Sampling Procedures: Diquat - Method 549.1.

What are SOCs and why do we sample for them?What are SOCs and why do we sample for them?

Residues of these chemical contaminants are Residues of these chemical contaminants are carried to surface water andcarried to surface water and

groundwater systems groundwater systems

Page 6: Safe Drinking Water Act Phase II & V Sampling Procedures: Diquat - Method 549.1.

Stormwater discharges

And even direct discharge And even direct discharge due to aerial spraying. due to aerial spraying.

Through farmland runoff

What are SOCs and why do we sample for them?What are SOCs and why do we sample for them?

Page 7: Safe Drinking Water Act Phase II & V Sampling Procedures: Diquat - Method 549.1.

What are SOCs and why do we sample for them?What are SOCs and why do we sample for them?

These chemicals have been shown to cause cancer These chemicals have been shown to cause cancer

in laboratory animals.in laboratory animals.

Page 8: Safe Drinking Water Act Phase II & V Sampling Procedures: Diquat - Method 549.1.

However, many of these contaminants can However, many of these contaminants can usually be removed by granular activated usually be removed by granular activated carbons (GAC), and several other types of carbons (GAC), and several other types of

treatment processes. treatment processes.

What are SOCs and why do we sample for them?What are SOCs and why do we sample for them?

Page 9: Safe Drinking Water Act Phase II & V Sampling Procedures: Diquat - Method 549.1.

There are 6 different methods for testing Phase II & V There are 6 different methods for testing Phase II & V Synthetic Organic Chemicals that are found on this CD-Synthetic Organic Chemicals that are found on this CD-Rom. They are: Rom. They are:

Semi Volatile Organic (SVOC) Chemicals Method 525.2Semi Volatile Organic (SVOC) Chemicals Method 525.2 Fumigants Method 551Fumigants Method 551 Herbicides Method 515.3Herbicides Method 515.3 Carbamates Method 531.1Carbamates Method 531.1 Diquat Method 549.1; andDiquat Method 549.1; and Cyanide Method 335.2Cyanide Method 335.2

This presentation will address Diquat Method 549.1This presentation will address Diquat Method 549.1

What are SOCs and why do we sample for What are SOCs and why do we sample for them?them?

Page 10: Safe Drinking Water Act Phase II & V Sampling Procedures: Diquat - Method 549.1.

State Guidelines – Rules – Sample State Guidelines – Rules – Sample

RequirementsRequirements

Be sure to check with Be sure to check with your state or tribal your state or tribal drinking water program drinking water program office for additional office for additional guidelines, rules and/or guidelines, rules and/or sample requirements sample requirements since they may be more since they may be more stringent than those stringent than those required by the federal required by the federal Safe Drinking Water Act. Safe Drinking Water Act.

Page 11: Safe Drinking Water Act Phase II & V Sampling Procedures: Diquat - Method 549.1.

SOC Sampling SuppliesSOC Sampling Supplies

Before beginning, it is important to have all of your Before beginning, it is important to have all of your supplies on hand. Here is a list of the suggested supplies on hand. Here is a list of the suggested

supplies you may need for SOC sampling:supplies you may need for SOC sampling:

Page 12: Safe Drinking Water Act Phase II & V Sampling Procedures: Diquat - Method 549.1.

Cooler for shipping and storage of your sampleCooler for shipping and storage of your samplewhile in transit between collection point and lab.while in transit between collection point and lab.

SOC Sampling SuppliesSOC Sampling Supplies

Page 13: Safe Drinking Water Act Phase II & V Sampling Procedures: Diquat - Method 549.1.

Bagged Ice for your shipping cooler. Bagged Ice for your shipping cooler.

SOC Sampling SuppliesSOC Sampling Supplies

Page 14: Safe Drinking Water Act Phase II & V Sampling Procedures: Diquat - Method 549.1.

PVC or unsupported Neoprene gloves which are PVC or unsupported Neoprene gloves which are necessary to keep your hands safe from sample necessary to keep your hands safe from sample

container preservative chemicals.container preservative chemicals.

SOC Sampling SuppliesSOC Sampling Supplies

Page 15: Safe Drinking Water Act Phase II & V Sampling Procedures: Diquat - Method 549.1.

Safety Goggles which are necessary to keep Safety Goggles which are necessary to keep your hands and eyes safe from sample your hands and eyes safe from sample

container preservative chemicals.container preservative chemicals.

SOC Sampling SuppliesSOC Sampling Supplies

Page 16: Safe Drinking Water Act Phase II & V Sampling Procedures: Diquat - Method 549.1.

Sample ContainersSample Containers

SOC Sampling SuppliesSOC Sampling Supplies

Page 17: Safe Drinking Water Act Phase II & V Sampling Procedures: Diquat - Method 549.1.

Lab slips, labels, and markers for sample containerLab slips, labels, and markers for sample containeridentificationidentification

SOC Sampling SuppliesSOC Sampling Supplies

Page 18: Safe Drinking Water Act Phase II & V Sampling Procedures: Diquat - Method 549.1.

Additional Recommended Items are:Additional Recommended Items are:

Paper towels for drying off the outside of your sample Paper towels for drying off the outside of your sample container after sampling.container after sampling.

SOC Sampling SuppliesSOC Sampling Supplies

Page 19: Safe Drinking Water Act Phase II & V Sampling Procedures: Diquat - Method 549.1.

Plastic storage baggies for ice andPlastic storage baggies for ice and

sample container sample container

SOC Sampling SuppliesSOC Sampling Supplies

Page 20: Safe Drinking Water Act Phase II & V Sampling Procedures: Diquat - Method 549.1.

Sample preparation instructionsSample preparation instructions

For this sampling For this sampling Method, The Method, The laboratory will laboratory will normally send you normally send you two- 250mL glass two- 250mL glass or plastic bottles or plastic bottles with an acid with an acid preservative added preservative added in the bottle.in the bottle.

Page 21: Safe Drinking Water Act Phase II & V Sampling Procedures: Diquat - Method 549.1.

Sample preparation instructionsSample preparation instructions

IMPORTANT:IMPORTANT: The laboratory supplying the The laboratory supplying the sample containers may send trip blanks, sample containers may send trip blanks, sometimes called field reagent blanks, along with sometimes called field reagent blanks, along with the sample containers. Trip blanks consist of the sample containers. Trip blanks consist of sample containers filled at the laboratory, that sample containers filled at the laboratory, that must remain sealed and must be shipped back to must remain sealed and must be shipped back to the lab . This is done to check if samples were the lab . This is done to check if samples were contaminated during shipment. contaminated during shipment.

Page 22: Safe Drinking Water Act Phase II & V Sampling Procedures: Diquat - Method 549.1.

As a general rule, As a general rule, proper washing of proper washing of hands is highly hands is highly recommended for recommended for the sample the sample collector.collector.

Sample preparation instructionsSample preparation instructions

Page 23: Safe Drinking Water Act Phase II & V Sampling Procedures: Diquat - Method 549.1.

Also, food, drink, and even 2nd hand cigarette Also, food, drink, and even 2nd hand cigarette smoke should never come into contact with the smoke should never come into contact with the sample or its containers. These foreign objects sample or its containers. These foreign objects have been suspected of causing false results in have been suspected of causing false results in

samples, so be sure to practice good clean sample samples, so be sure to practice good clean sample collection procedures.collection procedures.

Sample preparation instructionsSample preparation instructions

Page 24: Safe Drinking Water Act Phase II & V Sampling Procedures: Diquat - Method 549.1.

Do not sample with Do not sample with any containers that any containers that appear to have been appear to have been tampered with since tampered with since this may cause an this may cause an undesirable sample undesirable sample result.result.

Sample preparation instructionsSample preparation instructions

Page 25: Safe Drinking Water Act Phase II & V Sampling Procedures: Diquat - Method 549.1.

Sampling InstructionsSampling Instructions

The laboratory that supplies the sampling containers The laboratory that supplies the sampling containers may provide instruction with the kit for the type of may provide instruction with the kit for the type of

monitoring being performed. Be sure to refer to those monitoring being performed. Be sure to refer to those instructions when provided.instructions when provided.

Page 26: Safe Drinking Water Act Phase II & V Sampling Procedures: Diquat - Method 549.1.

Important Safety PrecautionsImportant Safety Precautions

Safety goggles and Safety goggles and

gloves gloves mustmust be worn. be worn.

Page 27: Safe Drinking Water Act Phase II & V Sampling Procedures: Diquat - Method 549.1.

Wash hands before and after sampling. Wash hands before and after sampling.

Important Safety PrecautionsImportant Safety Precautions

Page 28: Safe Drinking Water Act Phase II & V Sampling Procedures: Diquat - Method 549.1.

Important Safety PrecautionsImportant Safety Precautions

Caution-Hazard Caution-Hazard

Sample containers may contain liquid Sample containers may contain liquid preservatives. Liquid preservatives will cause preservatives. Liquid preservatives will cause burns. If it comes into contact with the skin or burns. If it comes into contact with the skin or eyes, flush with liberal amounts of water and seek eyes, flush with liberal amounts of water and seek immediate medical attention.immediate medical attention.

Page 29: Safe Drinking Water Act Phase II & V Sampling Procedures: Diquat - Method 549.1.

Select a state approved sampling location if Select a state approved sampling location if any have been designated. If not, select a any have been designated. If not, select a representative sampling location. For a surface representative sampling location. For a surface water system, the plant effluent tap might be an water system, the plant effluent tap might be an appropriate sampling location. For a well appropriate sampling location. For a well discharging directly into a distribution system discharging directly into a distribution system (entry point to the distribution system or (entry point to the distribution system or EPTDS), a tap on the well’s discharge piping EPTDS), a tap on the well’s discharge piping after any treatment would be appropriate. after any treatment would be appropriate.

Sampling ProceduresSampling Procedures

Page 30: Safe Drinking Water Act Phase II & V Sampling Procedures: Diquat - Method 549.1.

If possible, use a non-swivel faucet and remove all If possible, use a non-swivel faucet and remove all attachments, including any aerators, strainers and hoses. attachments, including any aerators, strainers and hoses. It is normally recommended not to take a sample at that It is normally recommended not to take a sample at that location if all attachments cannot be removed because location if all attachments cannot be removed because

they may alter the sample results.they may alter the sample results.

Sampling ProceduresSampling Procedures

Page 31: Safe Drinking Water Act Phase II & V Sampling Procedures: Diquat - Method 549.1.

Turn on the water tap Turn on the water tap and run the water for 2-and run the water for 2-3 minutes then reduce 3 minutes then reduce the flow so that the the flow so that the stream is stream is approximately ¼ inch approximately ¼ inch in diameter.in diameter. Do not Do not change the flow rate until change the flow rate until after sampling is after sampling is completed.completed.

Sampling ProceduresSampling Procedures

Page 32: Safe Drinking Water Act Phase II & V Sampling Procedures: Diquat - Method 549.1.

While the water is running for thoseWhile the water is running for those

2-3 minutes, completely fill out the 2-3 minutes, completely fill out the

labels and lab slip. Be sure to clearly labels and lab slip. Be sure to clearly

identify the system information, like identify the system information, like

the public water system identification the public water system identification

number, number, exact exact sample location, date and time of collection, and the sampler’s name. sample location, date and time of collection, and the sampler’s name.

If the sample collection point has a specific coded identification, include it on the label and If the sample collection point has a specific coded identification, include it on the label and sample submission form. Be sure to attach the label prior to sampling. A wet sample sample submission form. Be sure to attach the label prior to sampling. A wet sample container may not allow the label to properly adhere. container may not allow the label to properly adhere.

Sampling ProceduresSampling Procedures

Page 33: Safe Drinking Water Act Phase II & V Sampling Procedures: Diquat - Method 549.1.

Sampling ProceduresSampling Procedures

Caution-Hazard Caution-Hazard - Sample containers - Sample containers may contain acid or other liquid may contain acid or other liquid preservatives. These may cause burns. preservatives. These may cause burns. If they come into contact with your skin If they come into contact with your skin or eyes, flush with liberal amounts of or eyes, flush with liberal amounts of water and seek immediate medical water and seek immediate medical attention.attention.

Page 34: Safe Drinking Water Act Phase II & V Sampling Procedures: Diquat - Method 549.1.

Remove the cap from the container, keeping the Remove the cap from the container, keeping the container upright to prevent spilling any preservatives. container upright to prevent spilling any preservatives. Do no put the cap face down or put it in your pocket. Do Do no put the cap face down or put it in your pocket. Do not allow the inside of the cap, the inside of the not allow the inside of the cap, the inside of the container, or the container threads to be touched by any container, or the container threads to be touched by any object. DO NOT rinse out the container prior to object. DO NOT rinse out the container prior to sampling. sampling.

Sampling ProceduresSampling Procedures

Page 35: Safe Drinking Water Act Phase II & V Sampling Procedures: Diquat - Method 549.1.

Hold container at an angle pointing away form your Hold container at an angle pointing away form your face and carefully fill it to its shoulder. If acid is in face and carefully fill it to its shoulder. If acid is in the container, it will mix rapidly with the water and the container, it will mix rapidly with the water and may splatter a bit. Leave enough room in the bottle may splatter a bit. Leave enough room in the bottle so that the sample can be shaken to mix the so that the sample can be shaken to mix the preservative. Put the cap on the container, tighten it, preservative. Put the cap on the container, tighten it, and shake the bottle vigorously for one minute.and shake the bottle vigorously for one minute.

Sampling ProceduresSampling Procedures

Page 36: Safe Drinking Water Act Phase II & V Sampling Procedures: Diquat - Method 549.1.

Sampling ProceduresSampling Procedures

Remember that each “sample” consists of 2 to 3 Remember that each “sample” consists of 2 to 3 filled containers. Repeat the mentioned sampling filled containers. Repeat the mentioned sampling procedures and continue to fill additional procedures and continue to fill additional containers for each sample.containers for each sample.

Page 37: Safe Drinking Water Act Phase II & V Sampling Procedures: Diquat - Method 549.1.

Sampling ProceduresSampling Procedures

Complete the forms supplied by the Complete the forms supplied by the laboratory with the appropriate laboratory with the appropriate information such as public water information such as public water systems (PWS) identification number, systems (PWS) identification number, exact sample collection location, date exact sample collection location, date and time, type of sample collection (raw, and time, type of sample collection (raw, plant tap, entry point, or distribution), plant tap, entry point, or distribution), and type of analysis to be run. In many and type of analysis to be run. In many states, the same form that is filled out states, the same form that is filled out here will be used to report the analytical here will be used to report the analytical results. Also, complete a chain of results. Also, complete a chain of custody form if required. custody form if required.

Page 38: Safe Drinking Water Act Phase II & V Sampling Procedures: Diquat - Method 549.1.

Place the samples in a cooler. The trip blanks should Place the samples in a cooler. The trip blanks should still be in the cooler. Keep the samples at 2 degrees to 6 still be in the cooler. Keep the samples at 2 degrees to 6 degrees Celsius ( 36 degrees to 43 degrees Fahrenheit) degrees Celsius ( 36 degrees to 43 degrees Fahrenheit) and keep them away form direct light or gasoline and and keep them away form direct light or gasoline and solvent vapors. solvent vapors.

Pack the samples in a cooler with Ice. As a tip, it might Pack the samples in a cooler with Ice. As a tip, it might be a good idea to bag up the sample and the ice be a good idea to bag up the sample and the ice separately in the cooler. This will help prevent leakage separately in the cooler. This will help prevent leakage or contamination of the sample from the ice.or contamination of the sample from the ice.

Sampling ProceduresSampling Procedures

Page 39: Safe Drinking Water Act Phase II & V Sampling Procedures: Diquat - Method 549.1.

Deliver the samples to the laboratory or ship Deliver the samples to the laboratory or ship the samples by an overnight courier. This will the samples by an overnight courier. This will ensure prompt testing for the most accurate ensure prompt testing for the most accurate results. All samples must be received by the results. All samples must be received by the

laboratory within laboratory within 48 hours48 hours..

Sampling ProceduresSampling Procedures

Page 40: Safe Drinking Water Act Phase II & V Sampling Procedures: Diquat - Method 549.1.

If the laboratory has any additional If the laboratory has any additional recommendations or requirements, recommendations or requirements, they should be read and followed they should be read and followed

closely.closely.

Sampling ProceduresSampling Procedures

Page 41: Safe Drinking Water Act Phase II & V Sampling Procedures: Diquat - Method 549.1.

If you have any additional questions, please If you have any additional questions, please contact your state or tribal drinking water contact your state or tribal drinking water program office for assistance. program office for assistance.

Following the proper drinking water sample Following the proper drinking water sample collection procedures can lead to peace of mind, collection procedures can lead to peace of mind, knowing that the test results truly represent the knowing that the test results truly represent the quality of water your customers are drinking. After quality of water your customers are drinking. After all, isn’t our goal to ensure . . .all, isn’t our goal to ensure . . .

Sampling ProceduresSampling Procedures

Page 42: Safe Drinking Water Act Phase II & V Sampling Procedures: Diquat - Method 549.1.

SOC DiquatSOC DiquatMethod 549-1Method 549-1

Sampling Procedures Sampling Procedures

““Water Safe to Drink”Water Safe to Drink”