8 9 10 11 6 7 1 2 4 5 3 Table de nomenclature REP. DESIGNATION (FR) DESIGNATION (ENGLISH) QTE 1 CORPS VIDE SAC SACKTIP BODY 1 2 SAUTERELLE A CROCHET CLAMP LEVER 2 3 CONVOYEUR A ROULEAU ROLLER CONVEYOR 1 4 FILTRE REGULATEUR PNEUMATIQUE PNEUMATIC REGULATOR FILTER 1 5 SONDE DE NIVEAU LEVEL PROBE 1 6 COMPACTEUR DE SAC SACK COMPACTOR 1 7 PORTE VITREE GLASS DOOR 1 8 GANT DE PROTECTION PROTECTIVE GLOVE 2 9 TRAPPE D'ACCES SAC SACK ACCESS TRAP 1 10 VIBREUR PNEUMATIQUE PNEUMATIC VIBRATOR 2 11 VANNE DE VIDANGE PRODUIT OUTLET PRODUCT VALVE 1 CE PLAN EST LA PROPRIETE DE LA SOCIETE PALAMATIC - IL NE PEUT ÊTRE COPIE OU UTILISE SANS AUTORISATION 1:15 4 1 A 2 8 6 7 5 4 3 1 F D E C B A B C E F 1 7 8 Rue de l'Ecotais Z.A. de la Croix Rouge 35530 BRECE Echelle / Scale : REV : Dessiné par / Drawn by : 4 1 REV OBSERVATION A 2 8 6 7 5 4 3 1 D E C B A B C D E 1 7 8 Réf. Dossier / Project reference: PICHARD A 6 5 4 3 2 Description Désignation / Name : A3 Format : 6 5 4 3 2 DATE VIDE SAC CONFINEE PALAMATIC N'AYANT PAS EN CHARGE LE GENIE CIVIL, IL EST DE VOTRE RESPONSABILITE DE VOUS ASSURER DE LA RESISTANCE, DE LA STABILITE ET DE LA PLANEITE DE VOS SUPPORT OU SOLS RECEVANTS NOS EQUIPEMENTS, AUX DIFFERENTS EFFORTS ET CONTRAINTES AUQUELS ILS POURAIENT ETRE SOUMIS. CIVIL ENGINEERING WORKS ARE NOT INCLUDED IN PALAMATIC'S SCOPE OF SUPPLY.IT IS THE CLIENT'S RESPONSABILITY TO ENSURE THE STABILITY, RESISTANCE AND FLATNESS OF THE STRUCTURES AND TERRAIN ON WHICH, PALAMATIC'S EQUIPMENT WILL BE MOUNTED.THESE STRUCTURES AND TERRAIN MUST BE ABLE TO WITHSTAND THE DIFFERENT LOADS AND CONSTRAINTS BROUGHT ON BY THESE EQUIPMENTS A DIFFUSION 21-03-19 REVISEUR / REVISER 02 90 56 20 61 [email protected] CYP SECOMP800 N° Plan / Drawing number: PLAN D'INFORMATION / INFORMATION DRAWING [inch] mm DIMENSION : THIS DRAWING IS THE PROPERTY OF THE COMPANY PALAMATIC - IT CANNOT BE COPIED OR USED WITHOUT AUTHORIZATION

Transcript of SACKTIPSECOMP800-VIDE SAC CONFINE 800 - Palamatic Process · 2020. 12. 7. · 6'2,17" 1884 2'1,59"...

Page 1: SACKTIPSECOMP800-VIDE SAC CONFINE 800 - Palamatic Process · 2020. 12. 7. · 6'2,17" 1884 2'1,59" 650 longueur sac maximum / maximum sack length chargement sac/ sack loading decoupe

8

9

10

11

6

7

1

2

4

5

3

Table de nomenclatureREP. DESIGNATION (FR) DESIGNATION (ENGLISH) QTE

1 CORPS VIDE SAC SACKTIP BODY 1

2 SAUTERELLE A CROCHET CLAMP LEVER 2

3 CONVOYEUR A ROULEAU ROLLER CONVEYOR 1

4 FILTRE REGULATEUR PNEUMATIQUE PNEUMATIC REGULATOR FILTER 1

5 SONDE DE NIVEAU LEVEL PROBE 1

6 COMPACTEUR DE SAC SACK COMPACTOR 1

7 PORTE VITREE GLASS DOOR 1

8 GANT DE PROTECTION PROTECTIVE GLOVE 2

9 TRAPPE D'ACCES SAC SACK ACCESS TRAP 1

10 VIBREUR PNEUMATIQUE PNEUMATIC VIBRATOR 2

11 VANNE DE VIDANGE PRODUIT OUTLET PRODUCT VALVE 1

CE PLAN EST LA PROPRIETE DE LA SOCIETE PALAMATIC - IL NE PEUT ÊTRE COPIE OU UTILISE SANS AUTORISATION

1:15 41

A

2 86 75431

F

D

E

C

B

A

B

C

E

F

1 7 8

Rue de l'EcotaisZ.A. de la Croix Rouge35530 BRECE

Echelle / Scale : REV :

Dessiné par / Drawn by :

41

REV OBSERVATION

A

2 86 75431

D

E

C

B

A

B

C

D

E

1 7 8

Réf. Dossier / Project reference:PICHARD

A65432

Description

Désignation / Name :

A3Format :

65432DATE

VIDE SAC CONFINEE

PALAMATIC N'AYANT PAS EN CHARGE LE GENIE CIVIL, IL EST DE VOTRE RESPONSABILITE DE VOUS ASSURER DE LA RESISTANCE, DE LA STABILITE ET DE LA PLANEITE DE VOS SUPPORT OU SOLS RECEVANTS NOS EQUIPEMENTS, AUX DIFFERENTS EFFORTS ET CONTRAINTES AUQUELS ILS POURAIENT ETRE SOUMIS.

CIVIL ENGINEERING WORKS ARE NOT INCLUDED IN PALAMATIC'S SCOPE OF SUPPLY.IT IS THE CLIENT'S RESPONSABILITY TO ENSURE THE STABILITY, RESISTANCE AND FLATNESS OF THE STRUCTURES AND TERRAIN ON WHICH, PALAMATIC'S EQUIPMENT WILL BE MOUNTED.THESE STRUCTURES AND TERRAIN MUST BE ABLE TO WITHSTAND THE DIFFERENT LOADS AND CONSTRAINTS BROUGHT ON BY THESE EQUIPMENTS

A DIFFUSION21-03-19

REVISEUR / REVISER

02 90 56 20 61

[email protected]

CYP

SECOMP800N° Plan / Drawing number:

PLAN D'INFORMATION / INFORMATION DRAWING[inch]mmDIMENSION :

THIS DRAWING IS THE PROPERTY OF THE COMPANY PALAMATIC - IT CANNOT BE COPIED OR USED WITHOUT AUTHORIZATION

Page 2: SACKTIPSECOMP800-VIDE SAC CONFINE 800 - Palamatic Process · 2020. 12. 7. · 6'2,17" 1884 2'1,59" 650 longueur sac maximum / maximum sack length chargement sac/ sack loading decoupe

6'6,66"1998 HORS TOUT / OVERALL

0

1'

11,5

0"59

7

1'

4,65

"42

3

0

3'6,66"1084

1'

4,65

"42

3

4'1,78"1264

3'3,96"1015

5'6,

75"

1696

HO

RS T

OUT

/ O

VER

ALL

8'2,87"2511 HORS TOUT / OVERALL

2'10,96"

888

0

3'

7,03

"10

93

3'

9,77

"11

63

1'3,75"

400

3'

11,8

8"12

16

SACKTIP FERME / CLOSED

CE PLAN EST LA PROPRIETE DE LA SOCIETE PALAMATIC - IL NE PEUT ÊTRE COPIE OU UTILISE SANS AUTORISATION

1:15 42

A

2 86 75431

F

D

E

C

B

A

B

C

E

F

1 7 8

Rue de l'EcotaisZ.A. de la Croix Rouge35530 BRECE

Echelle / Scale : REV :

Dessiné par / Drawn by :

42

REV OBSERVATION

A

2 86 75431

D

E

C

B

A

B

C

D

E

1 7 8

Réf. Dossier / Project reference:PICHARD

A65432

Description

Désignation / Name :

A3Format :

65432DATE

VIDE SAC CONFINEE

PALAMATIC N'AYANT PAS EN CHARGE LE GENIE CIVIL, IL EST DE VOTRE RESPONSABILITE DE VOUS ASSURER DE LA RESISTANCE, DE LA STABILITE ET DE LA PLANEITE DE VOS SUPPORT OU SOLS RECEVANTS NOS EQUIPEMENTS, AUX DIFFERENTS EFFORTS ET CONTRAINTES AUQUELS ILS POURAIENT ETRE SOUMIS.

CIVIL ENGINEERING WORKS ARE NOT INCLUDED IN PALAMATIC'S SCOPE OF SUPPLY.IT IS THE CLIENT'S RESPONSABILITY TO ENSURE THE STABILITY, RESISTANCE AND FLATNESS OF THE STRUCTURES AND TERRAIN ON WHICH, PALAMATIC'S EQUIPMENT WILL BE MOUNTED.THESE STRUCTURES AND TERRAIN MUST BE ABLE TO WITHSTAND THE DIFFERENT LOADS AND CONSTRAINTS BROUGHT ON BY THESE EQUIPMENTS

A DIFFUSION21-03-19

REVISEUR / REVISER

02 90 56 20 61

[email protected]

CYP

SECOMP800N° Plan / Drawing number:

PLAN D'INFORMATION / INFORMATION DRAWING[inch]mmDIMENSION :

THIS DRAWING IS THE PROPERTY OF THE COMPANY PALAMATIC - IT CANNOT BE COPIED OR USED WITHOUT AUTHORIZATION

Page 3: SACKTIPSECOMP800-VIDE SAC CONFINE 800 - Palamatic Process · 2020. 12. 7. · 6'2,17" 1884 2'1,59" 650 longueur sac maximum / maximum sack length chargement sac/ sack loading decoupe

123°

7'2,

80"

2205

HO

RS T

OUT

/ O

VER

ALL

2'7,30"795

OUVERTURE / OPENING

1'10

,06"

560

OUV

ERTU

RE /

OPE

NIN

G

SACKTIP OUVERTE / OPEN

CE PLAN EST LA PROPRIETE DE LA SOCIETE PALAMATIC - IL NE PEUT ÊTRE COPIE OU UTILISE SANS AUTORISATION

1:15 43

A

2 86 75431

F

D

E

C

B

A

B

C

E

F

1 7 8

Rue de l'EcotaisZ.A. de la Croix Rouge35530 BRECE

Echelle / Scale : REV :

Dessiné par / Drawn by :

43

REV OBSERVATION

A

2 86 75431

D

E

C

B

A

B

C

D

E

1 7 8

Réf. Dossier / Project reference:PICHARD

A65432

Description

Désignation / Name :

A3Format :

65432DATE

VIDE SAC CONFINEE

PALAMATIC N'AYANT PAS EN CHARGE LE GENIE CIVIL, IL EST DE VOTRE RESPONSABILITE DE VOUS ASSURER DE LA RESISTANCE, DE LA STABILITE ET DE LA PLANEITE DE VOS SUPPORT OU SOLS RECEVANTS NOS EQUIPEMENTS, AUX DIFFERENTS EFFORTS ET CONTRAINTES AUQUELS ILS POURAIENT ETRE SOUMIS.

CIVIL ENGINEERING WORKS ARE NOT INCLUDED IN PALAMATIC'S SCOPE OF SUPPLY.IT IS THE CLIENT'S RESPONSABILITY TO ENSURE THE STABILITY, RESISTANCE AND FLATNESS OF THE STRUCTURES AND TERRAIN ON WHICH, PALAMATIC'S EQUIPMENT WILL BE MOUNTED.THESE STRUCTURES AND TERRAIN MUST BE ABLE TO WITHSTAND THE DIFFERENT LOADS AND CONSTRAINTS BROUGHT ON BY THESE EQUIPMENTS

A DIFFUSION21-03-19

REVISEUR / REVISER

02 90 56 20 61

[email protected]

CYP

SECOMP800N° Plan / Drawing number:

PLAN D'INFORMATION / INFORMATION DRAWING[inch]mmDIMENSION :

THIS DRAWING IS THE PROPERTY OF THE COMPANY PALAMATIC - IT CANNOT BE COPIED OR USED WITHOUT AUTHORIZATION

Page 4: SACKTIPSECOMP800-VIDE SAC CONFINE 800 - Palamatic Process · 2020. 12. 7. · 6'2,17" 1884 2'1,59" 650 longueur sac maximum / maximum sack length chargement sac/ sack loading decoupe

6'

2,17

"18

84

2'1,59"650

LONGUEUR SAC MAXIMUM / MAXIMUM SACK LENGTH

CHARGEMENT SAC/SACK LOADING

DECOUPE ET DECHARGEMENT DU SAC/SACK CUTTING AND UNLOADING

CE PLAN EST LA PROPRIETE DE LA SOCIETE PALAMATIC - IL NE PEUT ÊTRE COPIE OU UTILISE SANS AUTORISATION

1:15 44

A

2 86 75431

F

D

E

C

B

A

B

C

E

F

1 7 8

Rue de l'EcotaisZ.A. de la Croix Rouge35530 BRECE

Echelle / Scale : REV :

Dessiné par / Drawn by :

44

REV OBSERVATION

A

2 86 75431

D

E

C

B

A

B

C

D

E

1 7 8

Réf. Dossier / Project reference:PICHARD

A65432

Description

Désignation / Name :

A3Format :

65432DATE

VIDE SAC CONFINEE

PALAMATIC N'AYANT PAS EN CHARGE LE GENIE CIVIL, IL EST DE VOTRE RESPONSABILITE DE VOUS ASSURER DE LA RESISTANCE, DE LA STABILITE ET DE LA PLANEITE DE VOS SUPPORT OU SOLS RECEVANTS NOS EQUIPEMENTS, AUX DIFFERENTS EFFORTS ET CONTRAINTES AUQUELS ILS POURAIENT ETRE SOUMIS.

CIVIL ENGINEERING WORKS ARE NOT INCLUDED IN PALAMATIC'S SCOPE OF SUPPLY.IT IS THE CLIENT'S RESPONSABILITY TO ENSURE THE STABILITY, RESISTANCE AND FLATNESS OF THE STRUCTURES AND TERRAIN ON WHICH, PALAMATIC'S EQUIPMENT WILL BE MOUNTED.THESE STRUCTURES AND TERRAIN MUST BE ABLE TO WITHSTAND THE DIFFERENT LOADS AND CONSTRAINTS BROUGHT ON BY THESE EQUIPMENTS

A DIFFUSION21-03-19

REVISEUR / REVISER

02 90 56 20 61

[email protected]

CYP

SECOMP800N° Plan / Drawing number:

PLAN D'INFORMATION / INFORMATION DRAWING[inch]mmDIMENSION :

THIS DRAWING IS THE PROPERTY OF THE COMPANY PALAMATIC - IT CANNOT BE COPIED OR USED WITHOUT AUTHORIZATION