Specifications (Wall-mounted Model)
Type
Model NameIndoor Unit Outdoor Unit Power Supply [V, Phase, Hz]
MSZ-GE25VAD
MSZ-GE25VADMUZ-GE25VAD
1.1 - 2.5 - 3.50.205 - 0.560 - 1.145
4.21 / 4.464.02.9
19 - 21 - 29 - 36 - 4246 (58)
68 - 1881.3 - 3.2 - 4.1
0.255 - 0.730 - 1.2004.19 / 4.38
4.03.8
19 - 21 - 29 - 36 - 4248 (59)
68 - 1923.87.4
22 / 23295 x 798 x 232
10550 x 800 x 285
3010
9.52 / 6.3520 /12
MSZ-GE35VAD
MSZ-GE35VADMUZ-GE35VAD
1.1 - 3.5 - 4.00.205 - 0.920 - 1.430
3.67 / 3.803.04.4
19 - 22 - 30 - 36 - 4347 (61)
68 - 2121.6 - 4.0 - 5.3
0.340 - 0.990 - 1.6803.91 / 4.04
3.54.6
19 - 22 - 30 - 36 - 4348 (62)
68 - 1924.68.6
29 / 23 295 x 798 x 232
10550 x 800 x 285
3310
9.52 / 6.3520 /12
MSZ-GE50VAD
MSZ-GE50VADMUZ-GE50VAD
1.4 - 4.8 - 5.40.320 - 1.480 - 2.060
3.17 / 3.242.06.8
28 - 33 - 38 - 44 - 4954 (69)
108 - 2521.4 - 5.8 - 7.2
0.320 - 1.650 - 2.4903.44 / 3.52
2.57.4
28 - 33 - 37 - 43 - 4856 (69)
108 - 2427.4
13.043 / 39
295 x 798 x 23210
850 x 840 x 3305416
12.7 / 6.3530 / 15
MSZ-GE42VAD
MSZ-GE42VADMUZ-GE42VAD
0.9 - 4.2 - 4.80.160 - 1.260 - 1.940
3.25 / 3.332.05.8
26 - 30 - 35 - 40 - 4650 (62)
97 - 2131.4 - 5.4 - 6.0
0.270 - 1.540 - 2.0403.43 / 3.51
2.57.0
26 - 30 - 35 - 40 - 4651 (64)
97 - 2187.0
10.029 / 30
295 x 798 x 23210
550 x 800 x 2853610
9.52 / 6.3520 / 12
Inverter Heat Pump (R410A)
Capacity [Min-Rated-Max]
Total Input [Min-Rated-Max]
AEER/EER
Running Current [Rated]
Sound Pressure
Level
Air Volume (IN) [Quiet-SHi*]Capacity [Min-Rated-Max]
Total Input [Min-Rated-Max]
ACOP/COP
Running Current [Rated]
Sound Pressure
Level
Air Volume (IN) [Quiet-SHi*]
Input [Rated] (Cooling/Heating)
Dimensions [HxWxD]
Weight
Dimensions [HxWxD]
Weight
Breaker Size
Diameter (Gas/Liquid)
Max. Length/Height
Star Rating
IN [Quiet-Lo-Mid-Hi-SHi*]OUT (PWL)
Star Rating
IN [Quiet-Lo-Mid-Hi-SHi*]OUT (PWL)
CoolingHeating
kWkW
AdB(A)dB(A)
L/SkWkW
AdB(A)dB(A)
L/SAAW
mmkg
mmkgA
mmmoCoC
230V, Single, 50Hz, Outdoor unit power supply
MUZ-GE25/35/42VAD MUZ-GE50VAD
-10 ~ 46-15 ~ 24
Cooling
Heating
Starting Current
Max. Running Current
Indoor
Unit
Outdoor
Unit
Ext. Piping
Guaranteed Operating Range
[Outdoor]*SHi = Super HighNote : •MUZ-GE]]VAD is potentially demand response capable unit. DRC-101A is required.
•MSZ-GE22VA(D) is for MXZ connection only. (The indicated capacity is rated capacity if one unit is connected to MXZ.)•MSZ-GE50 meets MEPS criteria at partial load.
MXZconnection
DCInverter
PAMControl Econo Cool
AUTOVANE Flat Panel
Auto Restart
Cooling at
46 C̊/-10 C̊ Quick Clean
SelfDiagnosis
FailureRecall
Flareconnection30m
15m20m
12m
PureWhite
24-hour timer
ACO
SWING
Horizontal
WeeklyTimerOptional
M-NETconnection
Optional
Only
19dBGE22/25/35
Heating at
-15̊COptional
GE25/35/42 GE50
CatechinStandard filter Standard filter
Anti-allergyEnzyme
Compact
DemandResponseCapabilityGE25/35/42/50
Optional
Wi-FiInterface
-
Specifications (Wall-mounted Model)
Type
Model NameIndoor Unit Outdoor Unit Power Supply [V, Phase, Hz]
MSZ-GE60VAD
MSZ-GE60VADMUZ-GE60VAD
1.5 - 6.0 - 7.50.280 - 1.760 - 2.380
3.37 / 3.412.57.8
29 - 37 - 41 - 45 - 4955 (69)
163 - 3052.0 - 6.8 - 9.3
0.460 - 1.770 - 2.9403.80 / 3.84
3.07.8
29 - 37 - 41 - 45 - 4955 (69)
163 - 3057.8
14.548 / 62
325 x 1,100 x 23816
880 x 840 x 3305020
15.88 / 6.3530 / 15
MSZ-GE80VAD
MSZ-GE80VADMUZ-GE80VAD
2.4 - 7.8 - 9.20.570 - 2.460 - 3.580
3.14 / 3.172.0
10.830 - 37 - 41 - 45 - 49
55 (69)162 - 297
2.2 - 9.0 - 11.10.520 - 2.550 - 3.650
3.50 / 3.53 2.5
11.230 - 37 - 41 - 45 - 49
55 (69)170 - 297
11.216.6
58 / 58325 x 1,100 x 238
16880 x 840 x 330
5320
15.88 / 9.5230 / 15
MSZ-GE71VAD
MSZ-GE71VADMUZ-GE71VAD
2.4 - 7.1 - 8.70.570 - 2.130 - 3.370
3.30 / 3.332.09.4
30 - 37 - 41 - 45 - 4955 (69)
162 - 2972.2 - 8.1 - 9.9
0.520 - 2.110 - 3.2503.80 / 3.84
3.09.5
30 - 37 - 41 - 45 - 4955 (69)
170 - 2979.5
16.658 / 58
325 x 1,100 x 23816
880 x 840 x 3305320
15.88 / 9.5230 / 15
-10 ~ 46-15 ~ 24
Inverter Heat Pump (R410A)
Cooling
Heating
Starting Current
Max. Running Current
Indoor
Unit
Outdoor
Unit
Ext. Piping
Guaranteed Operating Range
[Outdoor]*SHi = Super HighNote : •MUZ-GE]]VAD is potentially demand response capable unit. DRC-101A is required. •MSZ-GE80 meets MEPS criteria at partial load.
Capacity [Min-Rated-Max]
Total Input [Min-Rated-Max]
AEER/EER
Running Current [Rated]
Sound Pressure
Level
Air Volume (IN) [Quiet-SHi*]Capacity [Min-Rated-Max]
Total Input [Min-Rated-Max]
ACOP/COP
Running Current [Rated]
Sound Pressure
Level
Air Volume (IN) [Quiet-SHi*]
Input [Rated] (Cooling/Heating)
Dimensions [HxWxD]
Weight
Dimensions [HxWxD]
Weight
Breaker Size
Diameter (Gas/Liquid)
Max. Length/Height
Star Rating
IN [Quiet-Lo-Mid-Hi-SHi*]OUT (PWL)
Star Rating
IN [Quiet-Lo-Mid-Hi-SHi*]OUT (PWL)
CoolingHeating
kWkW
AdB(A)dB(A)
L/SkWkW
AdB(A)dB(A)
L/SAAW
mmkg
mmkgA
mmmoCoC
230V, Single, 50Hz, Outdoor unit power supply
FailureRecall
Flareconnection30m
15m
SWING
Vertical
DCInverter
PAMControl Econo Cool
AUTOVANE
NanoPlatinum
Flat Panel
SWING
Horizontal
Wide Long
Auto Restart
SelfDiagnosis
24-hour timer
ACOWeekly
TimerOptional
M-NETconnection
Optional
Optional
Cooling at
-10̊CHeating at
-15̊CPure
WhiteWeekly
Timer
Built-in
MXZconnection
Powerful
DemandResponseCapability
GE60/71/80
Optional
Wi-FiInterface
Outdoor Unit
Indoor Unit
RemoteController
MSZ-GE SERIESHEAT PUMP
MUZ-GE60/71/80VAD
-
MITSUBISHI ELECTRIC CORPORATIONAAHEAD OFFICE: TOKYO BLDG., 2-YY 7-3, MA77 RUNOUCHI, CHIYOYY DA-KU, TOKYOYY 100-8310, JAPANPP
MITSUBISHI ELECTRIC AUSTRALIA PTY. LTD. (Incorporated in New South Wales) ABN 58 001 215 792
http://www.mitsubishielectric.com.au/New South Wales:348 Victoria Road, Rydalmere NSW 2116Ph: (02) 9684 7555 Fax: (02) 9898 1043
Newcastle:271 Brunker Road, Adamstown NSW 2289Ph: (02) 4978 7813 Fax: (02) 4978 7899
Canberra:Suit 3, Serron Cyber Centre 1st Floor, 12 Albany Street Fyshwick ACT 2609Mobile: 0408 650 822 Fax: (02) 6297 9067
Victoria/T// asmania:TTSuite 2,10 Compark Circuit Mulgrave VIC 3170Ph: (03) 9535 7800 Fax: (03) 9535 7801
Queensland/Northern TeTT rritory:Da Vinci Business ParkBuilding 101, 2A Boronia Rd Brisbane AirportPh: (07) 3623 2000 Fax: (07) 3630 6761
North QLD - ToTT wnsville:Level 1, 112 Denham St, ToTT wnsville QLD 4810Ph: (07) 4728 5223 Fax: (07) 3860 6761
South Australia:Suite 1, 224 Glen Osmond Rd, Fullarton SA 5063Ph: (08) 8338 1001 Fax: (08) 8340 0501
Western Australia:Unit 5, 329 Collier Road, Bassendean WA 6054WWPh: (08) 9377 3400 Fax: (08) 9377 3499
60 71 80Cooling Cooling CoolingHeating Heating Heating
29
3dBLess
32
29
3dBLess
32
30
3dBLess
33
30
3dBLess
33
30
3dBLess
33
30
3dBLess
33
High Energy Savings Achievedfor Entire Range of SeriesAll models in the series, from the low-capacity 25 to the high-capacity 80, have achieved the top energy efficiency in the industry. For home use, such as in bedrooms and living rooms, to light commercial use, such as in offices, our air conditioners are contributing to reduced energy consumption across a wide range.
*Comparison with MSZ-GA(B)25/35/50/60/71/80VA.
Cooling Heating
COP4.38
EER3.80
COP4.04
EER3.24
COP3.52
MSZ-GE25VAD MSZ-GE35VAD MSZ-GE50VAD
EER4.46
Based on connection of a demand response enabling device (DRED) via DRED interface DRC-101A, Demand Response Mode is activated in response to signals sent from the electric power company at times when it is necessary to reduce peak demand. (2.5kW–8.0kW)
Potentially Demand Response Capable
A “Quiet Mode” setting has been added to the fan speed settings, ensuring super-quiet operation below 20dB for model sizes 35 and under. Perfect for the bedroom; it’s so quiet you’ll check to see if it’s on.
Quiet OperationOnly
19dB
Size 25 35 50Cooling Cooling CoolingHeating Heating Heating
( Low )
(Quiet )
Series( Fan speed )
MSZ-GE19
2dBLess
21
19
2dBLess
21
19
3dBLess
22
28
4dBLess
32
28
2dBLess
30
19
3dBLess
22MSZ-GA/GB
Comparison of minimum indoor SPL (dB)
EER3.41
COP3.84
COP3.84
EER3.17
COP3.53
MSZ-GE60VAD MSZ-GE71VAD MSZ-GE80VAD
EER3.33
8%UP
7%UP
10%UP
12%UP 14%
UP 25%UP
22%UP
14%UP 4%
UP 17%UP
7%UP
16%UP
* Temperature can be preset to 10ºC when heating in the “i save” mode (except when connected to MXZ-8).
i save
"i save" is a simplified setting function that recalls the preferred (preset) temperature by pressing a single button on the remote controller. Press the same button twice to immediately return to the previous temperature setting. Using this function contributes to energy savings when, for example, leaving the room or going to bed.
“i save” Mode i save
22oc 18ocHeating Heating
i save
(60/71/80) (25/35/42/50)
DemandResponseCapability
This filter incorporates nanometre-sized platinum-ceramic particles that generate stable antibacterial and deodorising effects. The size of the three-dimensional surface has been increased as well, enlarging the filter capture area. These features give the nano platinum filter of the MSZ-GE60/71/80 models better dust collection performance than conventional filters. The superior air-cleaning effectiveness increases room comfort yet another level.
Nano Platinum Filter (60/71/80) NanoPlatinum
*Filter can be washed with water (air-cleaning effect is maintained)
3D surface (waved surface)
* Only MSZ-G Series with model name MUZ-GE]]VAD/MSZ-GE]]VAD are potentially demand response capable units.
MSZ-GE SERIESThe standard model MSZ-G units provide excellent energy-savings and operationis impressively silent. A vast series line-up is ready to ensure comfortable room environments in response to your air conditioning needs.