S-2Y2YBY-0.75_1.5_2.5mm
-
Upload
riski-suhardinata -
Category
Documents
-
view
4 -
download
0
description
Transcript of S-2Y2YBY-0.75_1.5_2.5mm
-
Standard
Properties
Signal cable for the signal installations along the railway tracks. Can be laid in ground, cable ducts and tubes.
Application
Signal Cable
S-2Y2YBY 0.75 mm, 1.5 mm and 2.5 mm
VE-K10/10
Construction
Solid copper conductor, soft annealed
Naturally coloured with a blue marking core in each layer
PE insulation LLPE-sheath black
1 layer steel tape with a thickness of 0.3 mm
PVC, UV resistant
All rights reserved. Any unauthorized usage, redistribution or reproduction of part or all of the content in any form will constitute an infringement of copyright. The data are only indicative and should not be considered a binding representation or warranty from nkt cables concerning a products properties or usability. The data page is not exhaustive and should be read in conjunction with nkt cables other product data sheets, whether published or not. nkt cables reserves the right to change the data page without prior notice.
Rated voltage
Max. storage temperature
Test voltage
Packaging
Color of sheath
Temperature range for handling RoHS
REACH
0.75 mm 400 Veff> 1.5 mm 800 Veff
40 C
0.75 mm 2500 Veff, 50 Hz - 2 min> 1.5 mm 3500 Veff, 50 Hz - 2 min
Wooden drums
Grey
-20C - +50C Comply with RoHS Directive
Comply with REACH Directive
6 5 4 3 2 1
1 2 3 4
5 6
Service temperature -30C - +60 C Approved by ETS/BB
-
Technical details
All rights reserved. Any unauthorized usage, redistribution or reproduction of part or all of the content in any form will constitute an infringement of copyright. The data are only indicative and should not be considered a binding representation or warranty from nkt cables concerning a products properties or usability. The data page is not exhaustive and should be read in conjunction with nkt cables other product data sheets, whether published or not. nkt cables reserves the right to change the data page without prior notice.
S-2Y2YBY 0.75 mm, 1.5 mm and 2.5 mm
No. of cores x cross section mm
mm2
5x0,75
10x0,75
15x0,75
20x0,75
30x0,75
40x0,75
60x0,75
80x0,75
100x0,75
5x1,5
10x1,5
15x1,5
20x1,5
30x1,5
40x1,5
60x1,5
80x1,5
Cable diameter nom.
mm
12.8
15.4
16.7
17.3
20.1
21.9
26.0
29.2
32.4
14.0
17.4
19.2
20.8
24.5
26.0
31.6
36.1
Weight of cable
kg/km
195
280
350
410
540
665
905
1175
1405
260
395
520
640
890
1105
1540
2000
Copper weight
kg/km
38
75
113
150
225
300
450
600
750
75
150
225
300
450
600
900
1200
Conductor DC resistance at 20 dg. C
/km
24.5
24.5
24.5
24.5
24.5
24.5
24.5
24.5
24.5
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
Insulation resistance
Gxkm
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
Mutual capacitance at 800 Hz
nF/km
100
100
100
100
100
100
100
100
100
120
120
120
120
120
120
120
120
-
Technical details
All rights reserved. Any unauthorized usage, redistribution or reproduction of part or all of the content in any form will constitute an infringement of copyright. The data are only indicative and should not be considered a binding representation or warranty from nkt cables concerning a products properties or usability. The data page is not exhaustive and should be read in conjunction with nkt cables other product data sheets, whether published or not. nkt cables reserves the right to change the data page without prior notice.
S-2Y2YBY 0.75 mm, 1.5 mm and 2.5 mm
No. of cores x cross section mm
mm2
100x1,5
5x2,5
10x2,5
15x2,5
20x2,5
30x2,5
40x2,5
60x2,5
80x2,5
100x2,5
Cable diameter nom.
mm
40.2
15.6
19.7
22.0
24.7
28.6
31.5
37.6
42.5
48.3
Weight of cable
kg/km
2445
330
525
710
915
1254
1590
2275
2930
3625
Copper weight
kg/km
1500
125
250
375
500
750
1000
1500
2000
2500
Conductor DC resistance at 20 dg. C
/km
12.1
7.28
7.28
7.28
7.28
7.28
7.28
7.28
7.28
7.28
Insulation resistance
Gxkm
10
10
10
10
10
10
10
10
10
10
Mutual capacitance at 800 Hz
nF/km
120
120
120
120
120
120
120
120
120
120