RULER Oil Analysis Biokem

18
RULER Oil Analysis Biokem

description

Every lubricant application can benefit from RULER testing / RULER Oil Analysis. By proactively measuring the oil’s remaining antioxidants (oxidation fighters) oil degradation can be predicted before risking equipment reliability and increased wear.

Transcript of RULER Oil Analysis Biokem

  • RULER Oil

    Analysis Biokem

  • Remaining Useful Life Evaluation Routine (RULER)

    Every lubricant application can benefit from

    RULER testing / RULER Oil Analysis. By

    proactively measuring the oils remaining antioxidants (oxidation fighters) oil

    degradation can be predicted before

    risking equipment reliability and increased

    wear.

  • RULER determines the remaining useful life of

    oils and is ASTM listed test method ASTM D6810 and ASTM D6971.

  • RULER

    predicts oil oxidation before it occurs

    customers no longer have to wait for

    oxidation to measure current levels

    Customers do not need to risk equipment

    reliability by running oxidised oils in their

    system before oxidation is detected

  • Oxidation of lubricating oil can reduce

    equipment reliability, equipment protection

    and can cause

    Increases in viscosity

    acid formation (increasing TAN)

  • lubricant degradation

    formation of varnish

    waste lubricant that must be replaced

  • The advantages of RULER over

    Viscosity, TAN, FTIR and wear metal analysis

    Many conventional testing techniques

    (kinematic viscosity, total acid number

    (TAN), infrared (IR) data, and wear metal

    analysis) are used to measure the extent of

    oil degradation and

  • only begin to show significant changes in

    the physical and chemical oil properties

    when the majority of the antioxidants have

    been depleted. By this stage the oil has

    already begun to substantially degrade.

  • RULER in comparison detects the remaining

    antioxidants and can be used to predict

    when oxidation will occur, allowing action to

    be taken before oil degradation risks

    equipment reliability and increases wear.

  • With RULER test, customers are able to proactively:

    Monitor the depletion rates of the

    antioxidant protection package in new

    and used oils.

    Quantify antioxidant levels of incoming

    and stored oil supplies.

  • Identify abnormal operating conditions

    prior to equipment failure following the

    detection of abrupt antioxidant depletion

    rates.

    Determine proper oil change intervals

    and extend oil change intervals through

    timely antioxidant additive replenishment.

  • Information based oil drains Vs Time based oil drains

    To ensure that a lubricant is not used past

    the end of its useful life, time based oil

    changes are inherently conservative, which

    often results in the discarding of lubricants

    that are still suitable for use.

  • Understanding and forecasting the

    oxidation process of oils (using RULER) will

    enable information based oil drains and

    add value to your Oil Analysis or Condition

    Monitoring Program.

  • For more details, visit us

    http://www.biokem.com.au/

    http://www.biokem.com.au/