RUKS ENGINEERING LTD

ENGINEERED OZONE SYSTEMS

Air Quality &Energy Management Systems

Air Quality &Energy Management Systems

UL Classified & CE Certified Fire & Smoke Test to UL 2043UL Recognized Transformer

Page 2: RUKS ENGINEERING LTD ENGINEERED OZONE SYSTEMS … Product Engineered-Ozone... · industrial effluents and odor, ... Conditions prevalent in air handling units and air ducts such as

18 Automatic Road, Unit 18, Brampton, Ontario, L6S 5N5, Canada. Toll Free: 1877 RUKSENG (1 877 785 7364), Tel: (905) 789 9652, Fax: (905) 789 0381, [email protected] www.rukseng.com2

Ruks Engineering Ltd is a Canadian EnvironmentEngineering Corporation, specialized in Indoor AirQuality Management and Energy ReductionSystems. Backed by professional engineers, highquality products manufactured to exactingstandards in their factory in Canada, close toleranceautomatic control systems, reliable monitoringstations, and above all, existing proven track historyof experience in wide variety of IAQ Applicationsand Energy Reduction Systems spread over 20countries, Ruks Engineered System is the preferredchoice for improved IAQ, with reduction in HVACCapital and Operating Costs. Ruks Engineering is thepioneering leader in this technology.

As an alternative to chemical filtration and costintensive method of using high intake of outdoorair, Ruks Engineered Ozone System presents cost

effective and environmentally friendly solution.Carbon and Chemical Filters are arrestant devicesand capture only contaminants which pass throughthem. Ruks Engineered Ozone System eliminatesthese, right at source of generation. RuksEngineered Ozone Systems are currently integratedin Indoor Air Quality and Energy Saving Systems inwide range of commercial applications, andcorporate offices. High quality and reliableequipment, coupled with vast proven experienceand extensive process knowledge, make RuksEngineering the ideal partner for ensuring yourIndoor Air is healthy, clean and cost effective.

With vast network of Distributors and Agents, RuksEngineering is well positioned to providecomprehensive design, installation and servicepackages.

Indoor Air Quality Testing and AnalysisOn site pilot plants

Detailed Feasibility Study and Return on Investment AnalysisCustom designed and engineered systems to meet individual needs

Manufacture, project management, Installation and commissioning assistanceFull maintenance and service contracts

• Reduction of VOC and gaseous Organic pollutants• Near total elimination of organic odor• Near total elimination of smoke due to cooking and cigarettes• Dramatic reduction of fungi in HVAC coil, duct and drain pan• Clean Ducts and AHU sections by eliminating bio adhesive force needed for particulate adherence to surface• Near Total elimination of Air Borne Bacteria in AC ducts, Cooling Coils and drain pan• Residual ozone level in Indoor space well below ASHRAE, OSHA, ACGIH, EPA and WHO permissible level• Regulation of outdoor air damper to maintain CO2

level to ASHRAE and OSHA standards• Reduction in HVAC plant capacity. Saves on capital cost of HVAC Systems, often sufficient to offset

investment on ozone systems and associated controls and monitors• Reduction in operating cost of HVAC system by reducing energy and water. In most applications, savings in operating cost over 1 to 2 years offset total investment on ozone system and associated controls and monitors. Life cycle cost savings is enormous• System is fully automatic, with VOC Sensor, Ozone Sensor, CO2 Sensor, and Controller• Provides 4 to 20 mA or 0 to 10 VDC for total integration to computerized Building Management and Automation Systems• Provides output to computer. May be used to provide time history records, records of residual VOC, Ozone, and CO2, retain hard copy records and management information reports• Modern, state of the art IAQ Monitors

RUKS ENGINEERED SYSTEMS ACHIEVE

Ruks Engineering is committedto keep your indoor space a clean environment

Page 3: RUKS ENGINEERING LTD ENGINEERED OZONE SYSTEMS … Product Engineered-Ozone... · industrial effluents and odor, ... Conditions prevalent in air handling units and air ducts such as

18 Automatic Road, Unit 18, Brampton, Ontario, L6S 5N5, Canada. Toll Free: 1877 RUKSENG (1 877 785 7364), Tel: (905) 789 9652, Fax: (905) 789 0381, [email protected] www.rukseng.com 3

WHAT IS VOC?VOC is Volatile Organic Compound. Interior of modern buildings is infestedwith wide range of Organic and Hydrocarbon gases, released fromsynthetically produced interior furnishings such as carpets, curtains, ceilingtiles, paint, fabric protective coatings and cleaning aids. Occupantscontributed VOC include cigarette smoke, body odor, deodorant, food odor.Outdoor air intake to HVAC System may introduce automotive andindustrial effluents and odor, common in Downtown and Industriallocations. Continuous presence of VOC, even in low concentrations,adversely affect Indoor Air Quality, as occupants breathe them continuously.Many Indoor VOC are classified toxic, carcinogenic or carcinogen promoters.Some are odorous. Some irritate mucous embranes. VOC should be reducedsignificantly for safety, health and long term care of occupants.Ruks Engineered Ozone System eliminates or reduces VOC dramatically .

WHAT IS ODOR?Odor is detection and interpretation of a specific organic gas, by human olfactory senses. All odor is caused by chemicals. Someodorous gases are toxic and or carcinogenic, example benzene (gasoline), toluene, and methane. Not all odor are harmful, nor allharmful gases odorous. Yet, all odor are classified as VOC within the realm of IAQ. Odor may exist as transient odor – odor thatlasts just as long as the activity causing it lasts, or resident odor – odor causing chemicals retained in cellulose substances such ascarpets, ceiling tiles, and furniture fabric, and released at all times. No system eliminates resident odor except Engineered OzoneSystem. There are no known units to quantify odor, except human judgment.Ruks Engineered Ozone System eliminates or reduces Transient and Resident Odor.

WHAT IS CO2?CO2 is Carbon Dioxide. Common sources of CO2 in indoor space areexhalation by occupants, migration from outdoor air, and coal or woodburning heaters. CO2 is not a VOC, not a carcinogen, not a carcinogenpromoter, nor is it toxic. However, it is important to ensure CO2

concentration is not high. At elevated levels, CO2 causes reducedconcentration, fatigue, loss of productivity and lethargy. Permissiblelevel of CO2 for most applications is 1000 PPM by ASHRAE and OSHA.

WHY DO HVAC SYSTEMS PROMOTE GROWTH OF FUNGI?Conditions prevalent in air handling units and air ducts such as temperature, humidity,moisture on cooling coil and drain pan, and porous surface of duct lining are congenial forgrowth and propagation of mold and fungi. Through air vents, they enter indoor space. Fungicause allergies, breathing disorders, irritation and loss of concentration.Ruks Engineered Ozone System eliminates or reduces Mold & Fungi dramatically .

WHY DO HVAC SYSTEMS PROMOTEGROWTH OF AIR BORNE BACTERIA?Mold and Fungi are living organisms and form source of food andnutrients upon which air borne bacteria grow and propagate. Legionellabacteria is one example. Through air vents, they enter indoor space andexpose occupants to these. Elimination of mold and fungi in AC ducts andcooling coil eliminates or reduces air borne bacteria.Ruks Engineered Ozone System eliminates or reduces air borne bacteriain AC ducts and Cooling Coil.

QUALITY COMFORT AND ECONOMYFUNDAMENTALS OF INDOOR AIR QUALITY (IAQ)

Page 4: RUKS ENGINEERING LTD ENGINEERED OZONE SYSTEMS … Product Engineered-Ozone... · industrial effluents and odor, ... Conditions prevalent in air handling units and air ducts such as

18 Automatic Road, Unit 18, Brampton, Ontario, L6S 5N5, Canada. Toll Free: 1877 RUKSENG (1 877 785 7364), Tel: (905) 789 9652, Fax: (905) 789 0381, [email protected] www.rukseng.com4

WHY DOES DUST ACCUMULATE IN AC DUCTS?Force of adhesion is necessary for any particulate to adhere to any surface. In AC ducts, this is provided by bio adhesive forcecontributed by mold and fungi. If these are eliminated or reduced, dust particulates do not have the force to stick to duct surface.Ducts remain clean at all times.Ruks Engineered Ozone System keeps AC ducts and Cooling Coil free of dust and particulate Contaminant.

WHAT IS OZONE? Ozone is 3 atom molecule of oxygen with weak bonds. It is a powerful oxidizingagent. It is an unstable gas and reverts quickly to diatomic oxygen molecule or O2.When present with VOC, it oxidizes them. In the presence of ozone, VOC is subjectto continuous oxidation, transforming it into several transient gases. Resultantgases are totally harmless or less harmful. Total VOC is dramatically reduced. Odoris result of VOC. As VOC are removed, odor is almost completely eliminated. Netresult is indoor space with significantly reduced VOC, odor and smoke.

Fungi propagate by absorbing ambient oxygen, by process ofosmosis. Ozone, with oxygen, enters through outermembranes of cells of fungi. Ozone oxidizes the organicmatter in fungi. This retards cell multiplication andpropagation of fungi. Gradually, their colonies diminish. In thepresence of Ozone, fungi will not recultivate. Low residual

ozone concentration generated in Ruks Engineered OzoneSystem does not function as fungicide. It eliminates fungi bygradually decolonizing them. Elimination of mold and fungideprives food and nutrients for air borne bacteria to grow andpropagate in duct and coil. Without adequate supply of food,bacteria do not grow in ducts and coil.

OZONE AND FUNGI

WHAT ARE THE PRECAUTIONS?Ozone is beneficial in reducing VOC, Odor and depleting fungi. It is very important to ensure residual level of ozone does notexceed regulatory maximum permissible level.

WHAT ARE PERMISIBLE CONCENTRATION OF OZONE BY REGULATORY BODIES?OSHA & ACGIH (USA): 0.1 PPM (100 PPB)FDA: 0.05 PPM (50 PPB)WHO: 0.05 PPM (50 PPB)ASHRAE: 0.05 PPM (50 PPB)

CAN OZONE REDUCE CO2?Ozone cannot remove or reduce CO2, as CO2 is not oxidizable.Conventional method of limiting CO2 buildup in indoorenvironment is by diluting with outdoor air with low CO2

content.

• Ruks Ozone Generators produce ozone at low production density per unit surface area of the corona plates. This is essential in ensuring rate of production of ozone is in relation to rate of increase of VOC• Ruks Total Air Quality Monitor CZ8 – Automatic monitoring system with high quality Sensors for monitoring residual VOC, Ozone and CO2. VOC is oxidized by ozone, thus conserving available oxygen in fresh air to dilute CO2.

CO2 Sensor modulates outdoor air damper to alter outdoor air intake to limit CO2• Results in reduced demand for outdoor air yet improved IAQ• Reduction of outdoor air results in reduced HVAC Plant Capacity and hence reduced Capital Cost of the HVAC System• Reduced outdoor air also results in savings in Energy Cost

HOW DOES RUKS ENGINEERED SYSTEM IMPROVE IAQ AND YET REDUCE HVAC CAPITAL AND OPERATING COSTS?

*System operates in conformity to ASHRAE standards and regulations of OSHA, FDA, ACGIH and WHO

Page 5: RUKS ENGINEERING LTD ENGINEERED OZONE SYSTEMS … Product Engineered-Ozone... · industrial effluents and odor, ... Conditions prevalent in air handling units and air ducts such as

18 Automatic Road, Unit 18, Brampton, Ontario, L6S 5N5, Canada. Toll Free: 1877 RUKSENG (1 877 785 7364), Tel: (905) 789 9652, Fax: (905) 789 0381, [email protected] www.rukseng.com 5

HOW TO ENSURE OZONE LEVEL IS BELOW PERMISSIBLE CONCENTRATION?• Use Ruks unique design Inline Duct Mounted, Low Production Density, Multi Plate Corona Ozone Generators• Operate corona on line frequency• Use automatic controllers to regulate ozone generation adequate to remove VOC• In occupied space, do not rely on manual controls, sense of smell or personal judgment• Use Fail Safe, Self Diagnosis with Fault Codes, Residual Ozone Monitor to ensure Ozone Generator is deactivated in the event Ozone Concentration exceeds Regulatory Permissible Levels - use Ruks Ozone Monitor CZ12• Where possible, interface control system to Building Management System

• Retain records and time history of levels of residual VOC and ozone• Do not use annular Corona tubes• Do not use portable ozone generators and generators without adequate controls• Do not use generators outside air stream that tube ozone into air ducts. Use generators in the air stream• Do not use corona that operates on higher than line frequency (60 or 50 Hz)• Use Ruks Total Air Quality Monitor CZ8 – Provides all of these features• Use Ruks Engineered Ozone System

WHY USE PLATE CORONA IN AIR STREAM, AND AVOID ANNULAR SPACE CORONA, FOR IAQ APPLICATIONS?

Assume a space where VOC is neutralized by ozone, where anarbitrary unit V represents the extent of VOC, and an arbitraryunit Oz represents ozone concentration. In a well balancedsystem, they both are very low. In this scenario, V and Oz arelow.

If pollution is now generated in this space, increase in VOC (δV)in relation to room volume is extremely low, in the order ofparts per million. Yet the adverse effect on IAQ of the space isvery high. To neutralize this small increase in VOC (δV), we needa small increase in ozone (δOz), and the generators shouldrespond to provide this as rapidly as δV changes. δOz/δT mustbe proportional to δV/δT. To achieve this, it is necessary to haveozone generator where production density of ozone (ozoneproduction per unit area of corona surface) is very low and

provide rapid response. That is, change of production of ozoneper unit time δOz/δT follows the same rate as δV/δT.

This is the key to achieving effective Indoor Air Quality, whereVOC is reduced to as low level as possible, and yet keep residualconcentration of ozone as low as possible. This is achieved onlyby the unique design of multi plate type of corona used in RuksOzone Generators, designed to produce minute density ofozone per unit area of corona surface, and yet have adequatecapacity to handle the load. Such system delineatesconcentration and quantity vectors, allowing concentrationvector to be held constant at low level, while allowing quantityvector to be altered, within reasonable limits. These aremounted inside the duct, thus providing the same media tosense VOC and Ozone.

V = Residual VOC, Oz = Residual Ozone, T = Time

*The health aspects associated with the use of this product and its ability to aid in disinfection of environment air have not been investigated by UL.

Use only UL Classified Products

Page 6: RUKS ENGINEERING LTD ENGINEERED OZONE SYSTEMS … Product Engineered-Ozone... · industrial effluents and odor, ... Conditions prevalent in air handling units and air ducts such as

18 Automatic Road, Unit 18, Brampton, Ontario, L6S 5N5, Canada. Toll Free: 1877 RUKSENG (1 877 785 7364), Tel: (905) 789 9652, Fax: (905) 789 0381, [email protected] www.rukseng.com6

FEATURES (With CZ8 Monitor & CZ6 Controller)• Digital read out of VOC, CO2, O3, Temperature and RH, in user selectable units at all times • Automatic continuous modulation of; ✔ Ozone Generators and Demand Load Ventilation, based on residual VOC level ✔ Automatic cut out of Ozone Generators, with or without alarm, if residual ozone concentration exceeds set value ✔ Outdoor air damper or Exhaust Air Fan, based on CO2 level ✔ Two or three way mixing or diverting valve for cooling or heating coil, based on Temperature ✔ Two way valve to control humidifier• NO (Normally Open) Dry Contact to activate total 5# User Selectable On Off devices to control VOC, CO2, O3, Temperature and RH.• User selectable alarm for VOC, CO2, O3, Temperature and RH• Real Time and Time History records of VOC, CO2, O3, Temperature, and RH, exceedance and alarm reports, options to record variation of outdoor air flow, at all times• 0-10 VDC interface to BAS (BMS) for VOC, O3, CO2, T and RH• Management Reports• No chemicals used. Environmentally friendly• Supports LAN

BENEFITS• Clean Indoor Environment with significantly reduced VOC, toxic gases, smoke, and odor• Near total elimination of Mold and Fungi• Near total elimination of dust and particulates in AC ducts and Cooling Coil• Near total elimination of Air Borne Bacteria in AC ducts• Clean HVAC ducts, air coil, and AHU sections• Residual CO2 within ASHRAE and OSHA standards• Reduction in Capital Cost of HVAC System• Significant reduction in energy and water cost to operate HVAC System

QUALITY, COMFORT AND ECONOMY

OZONE GENERATOR, IAQ MONITOR & VOC CONTROLLER - AIR FLOW SCHEMATIC DIAGRAM

Page 7: RUKS ENGINEERING LTD ENGINEERED OZONE SYSTEMS … Product Engineered-Ozone... · industrial effluents and odor, ... Conditions prevalent in air handling units and air ducts such as

18 Automatic Road, Unit 18, Brampton, Ontario, L6S 5N5, Canada. Toll Free: 1877 RUKSENG (1 877 785 7364), Tel: (905) 789 9652, Fax: (905) 789 0381, [email protected] www.rukseng.com 7

Ruks RobuTran TransformerMounted in AC ventilation ducts, high voltage secondary windings pose threatof fire, smoke, and electric short circuit. Water impregnation from cooling coilon transformer windings is invitation to fire, smoke and short circuit.

Ruks RobuTran Transformer will not fail, burn, smoke, elevate in temperature,even if short circuited at full load for indefinite period of time. When short circuitis removed, reverts to operation without damage. No dependence on fuse orcircuit breaker. An unique safety feature seldom seen on an electrical device.

Moisture carryover from cooling coil is no threat to unfailing Ruks RobuTranfailsafe Transformer. Operates even if fully immersed in water.

The only UL Recognized Transformer with UL Test for Safety against Fire andSmoke, in the industry.

Penetration of high voltage cable from Transformer Enclosureto Corona Plate Enclosure is with high quality PorcelainEmbedded Stainless Steel Solid Transmitter. Eliminates contactof high voltage conductor to generator housing, under allcircumstances. No dependence on cable insulation or rubberbushing with potential for insulation failures. Assures totalsafety against electrical hazards.

High Voltage Cable

High Voltage Cable in Ruks Ozone System are Silicone insulated,rated for high temperature and high voltage to 20KV, ozoneand corona resistant listed to UL 3239 and VW-1 Flame Test.Every part, component, fixture, corona plate bondingcompound, insulation, ceramic bushing, standoff, down to inkin the label, are individually listed to highest UL standards.

PORCELAIN EMBEDDED STAINLESS STEEL HIGH VOLTAGE TRANSMITTER

RUKS ROBUTRAN TRANSFORMERFire Tested to UL 2043

• Ruks RobuTran Transformer tested to UL 2043 and Recognized to UL 506.

• Ruks Procelain Embedded High Voltage Transmitter is UL Recognized.

• High Voltage Silicone Cable, ozone resistant, Recognized to UL 3239 and VW-1 Flame Test.

• All parts, components, bonding compound, bushing, stand off, paint, screen printing ink, individually recognized to highest UL standards

• All parts and components of the Generator are Fire Rated.

Ruks K series Generators are:• Classified to UL 1995 ABQK:

Air Conditioning Equipment Accessories, Air Duct Mounted.

• Tested to UL 2043: Fire Test for Heat and visible smoke release for Discreet Products and Accessories installed in Air Handling Spaces.

• CE Certified.

Ruks devotes utmost attention to details to highest standards of safety to humans and property against fire, smoke and electrical hazard.

Ruks RobuTran Transformer is:• Tested to UL 2043: Fire Test for Heat and Visible Smoke Release for

Discreet Products and Accessories installed in Air Handling Spaces• Recognized to UL 506: Standard for Safety and Specialty Transformer.

UNIQUE BUILT-IN SAFETY FEATURES

HIGH VOLTAGE TRANSMITTER

Safety of Humans and Property

is of highest priority.

Make NO COMPROMISE in your Project.

Take NO CHANCES.

Specify Ruks Systems

with incredible safety features.

Peace of Mind

with

Fail Safe, Fire Safe,

and

Smoke Safe System.

Peace of Mind

with

Fail Safe, Fire Safe,

and

Smoke Safe System.

UL Classified & CE CertifiedFire & Smoke Test to UL 2043

Page 8: RUKS ENGINEERING LTD ENGINEERED OZONE SYSTEMS … Product Engineered-Ozone... · industrial effluents and odor, ... Conditions prevalent in air handling units and air ducts such as

18 Automatic Road, Unit 18, Brampton, Ontario, L6S 5N5, Canada. Toll Free: 1877 RUKSENG (1 877 785 7364), Tel: (905) 789 9652, Fax: (905) 789 0381, [email protected] www.rukseng.com8

RUKS K SERIES™

RUKS K SERIES™ generators offer wide selection range,to suit every need and budget, providing highestflexibility and cost effective solution. Heavy dutygenerators to meet the most robust needs in theindustry. Large surface area of multiple plate type doublescreen corona, mounted on heavy duty generator head,fully enclosed in stainless steel body.

Factory assembled and wired. Ready for field installationwith minimum installation time. Complete with stainlesssteel mounting bracket. Operates on 110 to 120 volts, 60Hz or 220 to 240 volts, 50/60 Hz electrical supply. Lowpower consumption.

RUKS K2 TO K10 SERIESDimensions: Inches (mm)Operating Weight: 17 lbs. (7.7 kg.)Power Consumption: 100 Watts Max.Air velocity across generator preferably : 800 FPM (4.1 M/S)

All dimensions are subject to tolerance of +/- 1/8” (3mm)

Classified to

UL 1995 ABQK.

Tested to UL 2043.

CE Certified.

UL Classified & CE CertifiedFire & Smoke Test to UL 2043

RUKS K2 TO K10 SERIES

Page 9: RUKS ENGINEERING LTD ENGINEERED OZONE SYSTEMS … Product Engineered-Ozone... · industrial effluents and odor, ... Conditions prevalent in air handling units and air ducts such as

18 Automatic Road, Unit 18, Brampton, Ontario, L6S 5N5, Canada. Toll Free: 1877 RUKSENG (1 877 785 7364), Tel: (905) 789 9652, Fax: (905) 789 0381, [email protected] www.rukseng.com 9

RUKS K12 TO K20 SERIESDimensions: Inches (mm)Operating Weight: 20.1 lbs. (9 kg.)Power Consumption: 100 Watts Max.Air velocity across generator preferably : 800 FPM (4.1 M/S)

RUKS K24 TO K40 SERIESDimensions: Inches (mm)Operating Weight: 23.4 lbs. (10.6 kg.) Power Consumption: 100 Watts Max. Air velocity across generator preferably : 800 FPM (4.1 M/S)

All dimensions are subject to tolerance of +/- 1/8” (3mm)

RUKS K12 TO K20 SERIES RUKS K24 TO K40 SERIES

Classified to

UL 1995 ABQK.

Tested to UL 2043.

CE Certified.

UL Classified & CE CertifiedFire & Smoke Test to UL 2043

Page 10: RUKS ENGINEERING LTD ENGINEERED OZONE SYSTEMS … Product Engineered-Ozone... · industrial effluents and odor, ... Conditions prevalent in air handling units and air ducts such as

18 Automatic Road, Unit 18, Brampton, Ontario, L6S 5N5, Canada. Toll Free: 1877 RUKSENG (1 877 785 7364), Tel: (905) 789 9652, Fax: (905) 789 0381, [email protected] www.rukseng.com10

HEIGHT LINESLine 1: Height ≤ 15 Ft (4.6 M)

Line 2: Height > 15 Ft (4.6 M)

≤ 20 Ft (6.1 M)

Line 3: Height > 20 Ft (6.1 M)

≤ 25 Ft (7.6 M)

Line 4: Height > 25 Ft (7.6 M)

≤ 30 Ft (9.1 M)

APPLICATION LINESLine 1: Bar, Pub, Casino

Line 2: Food Court, Shopping Malls

Line 3: Banquet Hall, Ball Room

Line 4: Call Centre, Technology Park

Line 5: Corporate Office

SELECTION PROCEDURE

Required information:

• Area to be treated.

• Height (floor to suspended ceiling) of treated space.

• Intended use of the space; Eg. Restaurant, Bar, Lobby etc.

• Number of AHU serving the space.

1. Calculate area served by each AHU.

2. Enter chart A. Plot area served by AHU 1 on the

horizontal Axis.

3. Identify the Height Line in chart A.

4. Draw vertical line from point located in step 1, to

intersect with height line.

5. Identify the closest match to Application Line in chart B.

6. From the point located in step 4, draw horizontal line to

enter chart B and intersect with the Applications Line.

7. From the point of intersection, draw a vertical line down

to horizontal Axis. Read the machine size.

8. If it is between two sizes, choose the generator closest

9. If no Application Line is intersected, divide the area into

multiple number of smaller areas, repeat the Selection

Procedure, and choose multiple number of generators.

10. Repeat the same for other AHU.

EXAMPLE 1

Select Ozone Generator for Call Center (Business Process

Application).

Number of AHU is 1. Area is 1,200 Sq Ft (113 Sq M).

Height to ceiling is 14 Ft (4.30 M).

1. Identify Height Line in chart A. It is Line 1.

2. Identify Applications Line in chart B. It is Line 4.

3. Enter area 1,200 Sq Ft (113 Sq M) on Horizontal Axis of

chart A.

4. Draw vertical line to intersect with the identified Height

Line (Line 1).

5. From point of intersection, draw horizontal line to enter

chart B and intersect with the identified Applications

Line (Line 4).

6. From point of intersection, draw vertical line down to

Horizontal Axis.

7. Point of intersection on Horizontal Axis is K3. If multiple

AHU’s serve one common area, one set of IAQ Monitor

and Controller is adequate.

OZONE GENERATOR SELECTION CHART

Page 11: RUKS ENGINEERING LTD ENGINEERED OZONE SYSTEMS … Product Engineered-Ozone... · industrial effluents and odor, ... Conditions prevalent in air handling units and air ducts such as

18 Automatic Road, Unit 18, Brampton, Ontario, L6S 5N5, Canada. Toll Free: 1877 RUKSENG (1 877 785 7364), Tel: (905) 789 9652, Fax: (905) 789 0381, [email protected] www.rukseng.com 11

OZONE GENERATOR SELECTION CHART

K2 TO K5

K6 TO K10

CHART A CHART B

CHART A CHART B

Page 12: RUKS ENGINEERING LTD ENGINEERED OZONE SYSTEMS … Product Engineered-Ozone... · industrial effluents and odor, ... Conditions prevalent in air handling units and air ducts such as

18 Automatic Road, Unit 18, Brampton, Ontario, L6S 5N5, Canada. Toll Free: 1877 RUKSENG (1 877 785 7364), Tel: (905) 789 9652, Fax: (905) 789 0381, [email protected] www.rukseng.com12

OZONE GENERATOR SELECTION CHART

K12 TO K20

K24 TO K40

CHART A CHART B

CHART A CHART B

Page 13: RUKS ENGINEERING LTD ENGINEERED OZONE SYSTEMS … Product Engineered-Ozone... · industrial effluents and odor, ... Conditions prevalent in air handling units and air ducts such as

18 Automatic Road, Unit 18, Brampton, Ontario, L6S 5N5, Canada. Toll Free: 1877 RUKSENG (1 877 785 7364), Tel: (905) 789 9652, Fax: (905) 789 0381, [email protected] www.rukseng.com 13

CZ8

IAQ

MO

NIT

OR

- C

Z6C

CO

NTR

OLL

ER &

ELE

CTR

ICA

L SC

HEM

ATI

C C

ON

TRO

L D

IAGR

AM

0-10

VD

C A

NA

LOG

SIG

NA

LS F

OR

V0C,

O3,

CO

2, T

AN

D R

H5#

NO

(NO

RMA

LLY

OPE

N) D

RY C

ON

TACT

S,

FIEL

D A

SSIG

NA

BLE

TO A

NY

5 IA

Q P

ARA

MET

ERS,

VO

C, O

3, C

O2,

T A

ND

RH

MO

RE T

HA

N O

NE

NO

DRY

CO

NTA

CT M

AY B

E A

SSIG

NED

TO

AN

Y O

NE

PARA

MET

ERN

OT

ALL

SEN

SORS

MAY

BE

CON

NEC

TED

ON

ALL

PRO

JECT

S

Page 14: RUKS ENGINEERING LTD ENGINEERED OZONE SYSTEMS … Product Engineered-Ozone... · industrial effluents and odor, ... Conditions prevalent in air handling units and air ducts such as

18 Automatic Road, Unit 18, Brampton, Ontario, L6S 5N5, Canada. Toll Free: 1877 RUKSENG (1 877 785 7364), Tel: (905) 789 9652, Fax: (905) 789 0381, [email protected] www.rukseng.com14

• Designed and manufactured in Canada, to highest Safety Standards

• Transformer Fire, Smoke, and Short Circuit safe. UL 506 Recognized and Tested to

UL 2043

• All parts and components are individually UL Listed or UL Recognized

• Generator is UL Classified to UL 1995 and Tested for Safety against Fire & Smoke

to UL 2043

• Industrial, heavy duty ozone generators for 120 or 220 Volts, 60 or 50 Hz frequency,

adaptable to all operating conditions, altitudes, ambient air temperatures and

relative humidity

• High efficiency, Low Production Density double screen multiple corona discharge plates

• High voltage dielectric ceramic plates manufactured to strict geometric tolerances

• 60 Hz or 50 Hz power supply by dry transformers with Cross Ferro Magnetic Core

• Power regulation by auto or manual controller

• Advanced instrumentation and control

• Production regulation between 100% and 10% automatically or manually

• Total automation capability

• Computer interface capability

• Robust stainless steel enclosure

• External control and monitoring capability

• Flexible to locate in new, existing or OEM equipment

• Low maintenance with high reliability

• Fire and Smoke Safety

QUALITY + ECONOMY + SAFETY

Page 15: RUKS ENGINEERING LTD ENGINEERED OZONE SYSTEMS … Product Engineered-Ozone... · industrial effluents and odor, ... Conditions prevalent in air handling units and air ducts such as

18 Automatic Road, Unit 18, Brampton, Ontario, L6S 5N5, Canada. Toll Free: 1877 RUKSENG (1 877 785 7364), Tel: (905) 789 9652, Fax: (905) 789 0381, [email protected] www.rukseng.com 15

OTHER PRODUCTS BY RUKS

Total IAQ Monitor

• CZ8-PD Touch Screen Color Display

• CZ8-AD Monochrome Display

• CZ8-LAN LAN, BacNet, ModBus, EtherNet

• CZ12 Supervisory Ozone Monitor

• CZ6-SC Auto VOC Sensor Controller

• CZ6-C Controller

CZ8-PDCZ8-AD

CZ8-LAN CZ12

CZ6-SC CZ6-C

GERMITRON - UVGI

ODONASH

COILOTRON

ODOTRON

GERMITRON - UVGI for IAQ• Eliminates air borne Bacteria and

Virus in Ventilation Ducts• 0 - 10 V output• RS 232• BMS Interface

ODONASH• Eliminates H2S & Odor from STP & Sewage Lift Stations• Performance proven with H2S & Ozone Monitor• Cost effective• Quick ROI

ODOTRONMinimizes or eliminates odor/VOC from:• Kitchen Exhaust Air• Exhaust Air from Food Processing & Dairy Plants• Laundry Exhaust Air• Exhaust Air from Solid Waste & Garbage Compacting Rooms• Exhaust Air from Building Service

COILOTRON - UVGI Cooling Coil• Keeps cooling and heating coils free of Bacteria, Mold and

Pathogens

Page 16: RUKS ENGINEERING LTD ENGINEERED OZONE SYSTEMS … Product Engineered-Ozone... · industrial effluents and odor, ... Conditions prevalent in air handling units and air ducts such as

INTERNATIONAL SALES AND DISTRIBUTION:

RUKS ENGINEERING LTD18 AUTOMATIC ROAD, UNIT 18 BRAMPTON, ONTARIO, L6S 5N5, CANADA Toll Free: 1 877 RUKSENG (1 877 785 7364)TEL: (905) 789 9652. FAX: (905) 789 0381 [email protected] www.rukseng.com

FACTORY:

RUKS CANADA LTD.ONTARIO, CANADA

Specifications and other details subject to change without notice Cat #: RE A02 008 Rev 5-01/12

YOUR DISTRIBUTOR:

OZONE GENERATOR PRODUCT SPECIFICATIONS1. Ozone Generator shall be self contained unit, with all components

factory assembled in one neat, compact package, suitable for duct mounting.

2. Components in contact with air shall be enclosed in stainless steel casing 18 G thick with sufficient stamped integral openings to allowadequate flow of air over the corona discharge plates.

3. Method of ozone production shall be by principle of corona discharge, with multiple numbers of double sided corona plates. Production density of ozone per unit surface area of corona surfaceshall be very low. Ozone shall be produced from the supply air of AHU/Fan. Air pressure over the corona surface shall not exceed air pressure in the duct. Electrical frequency applied on corona plates shall be the same as line frequency (60 Hz or 50 Hz). All corona plates shall be housed in a common stainless steel enclosure.

4. Detection/Sensing of VOC and production of ozone shall be in the same gaseous medium.

5. Corona plates shall be mounted on generator head, specially manufactured to close tolerance, of material that repels accumulation of sediments from tar, nicotine and grease.

6. The Transformer shall be electrical induction type. Solid state voltage converter shall not be acceptable. The Transformer shall be Cross Ferro Magnetic Type. Secondary windings shall not burn, generate smoke, or elevate greater than 90ºF (32ºC), even if the high voltage secondary output is short circuited for extended period of time, in full load conditions. Upon removal of the short circuit, the transformer shall revert to normal operation without any damage or loss of efficiency, or reduced insulation capacity, or blow out of fuse, or trip of circuit breaker.

7. The transformer shall be fully encapsulated. The encapsulation is to ensure the transformer windings and core are fully impregnated with epoxy rated for use in electrical equipment. The epoxy shall penetrate into various layers of primary and secondary windings, and into the various sections of the core. This is to ensure electrical spark, if any, shall be contained and isolated within the specific spotof occurrence in the windings, and temperature elevation if any shall be contained and isolated within the specific spot of occurrence of the winding or in the layers of the core. The epoxy for encapsulation shall be fire rated to UL94V0. The electrical properties of the epoxy for this encapsulation shall be ;a. Dielectric strength at 23ºC not less than 425 volt/milb. Voltage resistivity at 23ºC not less than 2 x 1015 Ohm Cm

8. The encapsulation of the transformer shall be done in a one piece die cast metallic enclosure 18 G CRS. The top cover shall be riveted with a fire rated epoxy to UL 94V0. This shall ensure the transformer is completely fire rated and non flammable.

9. The metallic enclosure and encapsulation shall also render the transformer totally safe to operate even if there is settlement and deposition of moisture or water on the transformer due to carry over moisture from Cooling Coil. The transformer shall not burn, short circuit or be damaged, even if fully immersed in water.These are essential safety prerequisites as the Transformer/Generator is installed in the Air Conditioning Duct, andthe facility houses human occupants.

10. Entire Transformer shall be Tested to UL2043: Fire Test for Fire & Visible Smoke Release for Discreet Products & Accessories Installed in Air Handling Space and Recognized to UL506: Safety Specialty Transformer.

11. Penetration of high voltage conductor from Transformer Enclosure to Corona Enclosure shall be through Embedded Porcelain SS Solid Transmitter. Cable insulation, rubber, synthetic or ceramic bushing

shall not be used as reliable insulation for enclosure penetration of high voltage.

12. Primary of Transformer shall be rated for input voltage varying from 0 to 110V (0 to 220V)

13. High voltage electrical wire from the transformer secondary terminal to Porcelain Embedded Transmitter, and further from Transmitter to Corona contact plates shall be rated for 20KV, 150ºC, certified to be ozone and corona resistant, have high flexibility, andshall be silicone insulated. Wire diameter shall not be less than 18 AWG. The wire shall be rated to UL3239 and VW-1 Flame Test. These shall be stamped on the wire. This is essential and cannot be waived from safety standpoint, as this wire carries high voltage.

14. At client’s request, pre shipment inspection and testing of the equipment shall be provided to the user or to the consultant, and or his authorized representative at the manufacturer’s facility. Besides the normal tests, following tests are mandatory;a. Transformer secondary output, under full voltage and load will

be subject to short circuit continuously for minimum of 24 hours. The primary and secondary windings shall not burn nor elevate intemperature greater than 90ºF (32ºC).

b. Upon release of the short circuit, the transformer shall revert to normal operation without any change or modification or repair, or fuse blow out, or trip of circuit breaker.

c. Demonstrate safe and undamaged operation of the transformer at full secondary voltage and load, with transformer fully immersed in a tank of water.

d. At inspectors instructions, cut open a transformer through the windings and core to demonstrate the penetration of the encapsulation epoxy into various layers of primary and secondarywindings, and into the core.

e. Demonstrate that high voltage wire is stamped with ratings of voltage to 20KV, temperature to 150ºC, and UL rating 3239 and UL VW-1.

15. The generator shall be suitable for mounting in duct with airflow inhorizontal or vertical or angular direction, and for air flow in eitherdirection, right to left, or top to bottom, or vice versa.

16. The generator shall have the feature for interlock to motor of the AHU, to prevent start of the generator unless the fan is energized.

17. Each and every part and component of the generator including bushing, grommet, corona plate, standoff, paint, and ink in printing labels, shall be fire resistant, and individually listed to UL standards.

18. All parts and components, bonding compound, bushing, standoff, paint, and screen printing ink shall be individually listed to highest UL standards.

19. The generator shall be provided with stainless steel flange in either side to enable mounting to metal frame, to be installed inside the duct.

20. Ozone Generator shall be manufactured to permit easy withdrawals and refitting in duct with minimum use of tools or hardware to refit the generator to duct.

21. Generator output shall be suitable for modulation by automatic or manual controls.

22. The generator shall be rated for operation on 0 to 100 % RH. 23. The generator shall be suitable for operation on electrical supply

220 to 240 (110 – 220) Volts, Single Phase, 50/60 Hz 3 wire system.24. The Generator shall be Classified to UL 1995 ABQK and Tested and

Certified for Safety against Fire and Smoke to UL 2043. It shall be CE Certified.

UL Classified & CE CertifiedFire & Smoke Test to UL 2043