RSL Energy Efficiency and STC Ratings Energy efficiency and beauty at your doorway! July 2017

Transcript of RSL Energy Efficiency and STC Ratings - RSL …rslinc.com/pdf/Energy-STC-Ratings.pdf · RSL Energy...

Page 1: RSL Energy Efficiency and STC Ratings - RSL …rslinc.com/pdf/Energy-STC-Ratings.pdf · RSL Energy Efficiency and STC Ratings Energy efficiency and beauty at your doorway! July 2017

RSL Energy Efficiencyand STC Ratings

Energy efficiency and beauty at your doorway!

July 2017

Page 2: RSL Energy Efficiency and STC Ratings - RSL …rslinc.com/pdf/Energy-STC-Ratings.pdf · RSL Energy Efficiency and STC Ratings Energy efficiency and beauty at your doorway! July 2017

U.S. ENERGY STAR® Criteria for Doors

Climate Zone Map

Northern

North-Central

South-Central

Southern

The U.S. standards include criteria for air leakage. Swinging doors cannot exceed 0.5 cfm/ft.

Glazing Level U-Factor SHGC

Opaque < or = 0.17 No criteria

< or = 1/2 Doorlight < or = 0.25 < or = 0.25

> or = 1/2 Doorlight < or = 0.30 < or 0.40 for Northern and North-Central Zones

....< or = 0.25 for Southern and South-Central Zones

Page 3: RSL Energy Efficiency and STC Ratings - RSL …rslinc.com/pdf/Energy-STC-Ratings.pdf · RSL Energy Efficiency and STC Ratings Energy efficiency and beauty at your doorway! July 2017

Energy Efficiency Ratings in Steel Doors

U-Factor: Defines the amount of heat loss. The lower the value, the less heat is transmitted through the entry door.

Solar Heat Gain Coefficient (SHGC): The portion of directly transmitted and absorbed solar energy that enters the interior. The lower the value, the less heat is transmitted through the entry.

Daylight Transmission/Visible Transmission (DT/VT): Measures how much light comes through the entry. The higher the value, from 0 to 1, the more daylight is let in over the unit area of the entry.

The performance ratings above were developed by Architectural Testing using applicable NFRC procedures for determining whole product performance. The ratings are determined for a fixed set of conditions and specs.

When installed in the proper door, select RSL doorglass products meet regional ENERGY STAR® thermal performance standards as defined by the U.S. Department of Energy (DOE) and Natural Resources-Canada (NR-Can). Energy efficiency ratings for RSL doorglass products vary by door construction, and the size and materials of doorglass assembly.

All Zones North & North-Central Zones

Meets Energy Star Criteria

1/2”Clear

1/2”Std

Low-E

1/2” ClearGBG

1/2” StdLow-EGBG

1”Clear

1” StdLow-E

1” StdLow-EGBG

BBGClear

(Raised)

BBGLow-E

(Raised)

BBGClear

(Lowered)

1” Decorative

ImpactClear

Impact Std

Low-E

Impact GBG

Std Low-E

Impact Decorative

1” Protector

Clear

1” ProtectorCL-GBG

1” Protector

Std Low-E

1” Protector

Low-E-GBG

Half Light U-Factor 0.25 0.23 0.25 0.23 0.24 0.21 0.21 0.26 0.23 0.22 0.22 0.23 0.21 0.21 0.21 0.24 0.24 0.22 0.22

SHGC 0.17 0.14 0.16 0.13 0.17 0.14 0.13 0.17 0.14 0.06 0.12 0.14 0.13 0.11 0.11 0.15 0.14 0.14 0.13

DT/VT 0.17 0.15 0.16 0.14 0.17 0.15 0.14 0.17 0.16 - 0.13 0.16 0.15 0.13 0.12 0.17 0.15 0.15 0.14

3/4 Light U-Factor 0.29 0.26 0.29 0.26 0.27 0.24 0.24 0.30 0.26 0.25 0.25 0.26 0.23 0.23 0.23 0.28 0.28 0.24 0.24

SHGC 0.23 0.19 0.21 0.17 0.23 0.19 0.17 0.23 0.19 0.07 0.17 0.19 0.18 0.15 0.14 0.20 0.18 0.19 0.17

DT/VT 0.23 0.21 0.21 0.19 0.23 0.21 0.19 0.23 0.21 - 0.18 0.22 0.20 0.17 0.17 0.22 0.20 0.20 0.18

Full Light U-Factor 0.34 0.30 0.34 0.29 0.32 0.27 0.27 0.35 0.30 0.29 0.28 0.30 0.26 0.26 0.26 0.32 0.32 0.27 0.27

SHGC 0.30 0.25 0.28 0.23 0.30 0.25 0.23 0.30 0.26 0.09 0.22 0.25 0.24 0.21 0.19 0.27 0.25 0.25 0.23

DT/VT 0.31 0.28 0.28 0.25 0.31 0.28 0.25 0.31 0.29 - 0.24 0.30 0.27 0.23 0.23 0.30 0.27 0.28 0.25

36” & 3/4 Oval

48” & Large Oval

64” & 80”

Page 4: RSL Energy Efficiency and STC Ratings - RSL …rslinc.com/pdf/Energy-STC-Ratings.pdf · RSL Energy Efficiency and STC Ratings Energy efficiency and beauty at your doorway! July 2017

Energy Efficiency Ratings in Fiberglass Doors

1/2”Clear

1/2”Std

Low-E

1/2” ClearGBG

1/2” StdLow-EGBG

1”Clear

1” StdLow-E

1” StdLow-EGBG

BBGClear

(Raised)

BBGLow-E

(Raised)

BBGClear

(Lowered)

1” Decorative

ImpactClear

Impact Std

Low-E

Impact GBG

Std Low-E

Impact Decorative

1” Protector

Clear

1” ProtectorCL-GBG

1” Protector

Std Low-E

1” Protector

Low-E-GBG

Half Light U-Factor 0.25 0.23 0.25 0.22 0.24 0.21 0.21 0.26 0.23 0.22 0.22 0.23 0.21 0.21 0.21 0.24 0.24 0.22 0.22

SHGC 0.17 0.14 0.16 0.13 0.17 0.14 0.13 0.17 0.14 0.06 0.12 0.14 0.13 0.11 0.11 0.15 0.14 0.14 0.13

DT/VT 0.17 0.15 0.16 0.14 0.17 0.15 0.14 0.17 0.16 - 0.13 0.16 0.15 0.13 0.12 0.17 0.15 0.15 0.14

3/4 Light U-Factor 0.29 0.26 0.28 0.25 0.27 0.23 0.23 0.30 0.26 0.25 0.24 0.26 0.23 0.23 0.24 0.27 0.27 0.24 0.24

SHGC 0.23 0.19 0.21 0.17 0.23 0.19 0.17 0.23 0.19 0.07 0.17 0.19 0.18 0.15 0.17 0.20 0.18 0.19 0.17

DT/VT 0.23 0.21 0.21 0.19 0.23 0.21 0.19 0.23 0.21 - 0.18 0.22 0.20 0.17 0.18 0.22 0.20 0.20 0.18

Full Light U-Factor 0.34 0.30 0.33 0.29 0.31 0.26 0.26 0.34 0.30 0.29 0.28 0.30 0.26 0.26 0.26 0.32 0.32 0.27 0.27

SHGC 0.30 0.25 0.28 0.23 0.30 0.25 0.23 0.30 0.26 0.09 0.22 0.25 0.23 0.21 0.19 0.27 0.25 0.25 0.23

DT/VT 0.31 0.28 0.28 0.25 0.31 0.28 0.25 0.31 0.29 - 0.24 0.30 0.27 0.23 0.23 0.30 0.27 0.28 0.25

36” & 3/4 Oval

48” & Large Oval

64” & 80”

U-Factor: Defines the amount of heat loss. The lower the value, the less heat is transmitted through the entry door.

Solar Heat Gain Coefficient (SHGC): The portion of directly transmitted and absorbed solar energy that enters the interior. The lower the value, the less heat is transmitted through the entry.

Daylight Transmission/Visible Transmission (DT/VT): Measures how much light comes through the entry. The higher the value, from 0 to 1, the more daylight is let in over the unit area of the entry.

The performance ratings above were developed by Architectural Testing using applicable NFRC procedures for determining whole product performance. The ratings are determined for a fixed set of conditions and specs.

When installed in the proper door, select RSL doorglass products meet regional ENERGY STAR® thermal performance standards as defined by the U.S. Department of Energy (DOE) and Natural Resources-Canada (NR-Can). Energy efficiency ratings for RSL doorglass products vary by door construction, and the size and materials of doorglass assembly.

All Zones North & North-Central Zones

Meets Energy Star Criteria

Page 5: RSL Energy Efficiency and STC Ratings - RSL …rslinc.com/pdf/Energy-STC-Ratings.pdf · RSL Energy Efficiency and STC Ratings Energy efficiency and beauty at your doorway! July 2017

Sound Transmission Class (STC) Ratings

Sound Transmission Class (STC) RatingsIn Steel and Fiberglass Doors

1/2”Clear

1/2”Std

Low-E

1/2” ClearGBG

1/2” StdLow-EGBG

1”Clear

1” StdLow-E

1” StdLow-EGBG

BBGClear

(Raised)

BBGLow-E

(Raised)

BBGClear

(Lowered)

ImpactClear

Impact Std

Low-E

Impact Std Low-E

GBG

1” Protector

Clear

1” ProtectorCL-GBG

1” Protector

Std Low-E

1” Protector

Low-E-GBG

Full Lite22” x 64”

29 29 30 30 28 28 29 32 32 32 38 38 39 37 37 37 37

Full Lite22” x 80”

26 26 30 30 27 27 31 31 31 31 38 38 37 36 37 36 37

Sound Transmission (STC): Measures how much sound comes through the entry. The higher the value, the more sound transmission is reduced.

The performance ratings above were developed by Architectural Testing using applicable NFRC procedures for determining whole product performance.

The ratings are determined for a fixed set of conditions and specs.