RS3-FIM series Migration
description
Transcript of RS3-FIM series Migration
![Page 1: RS3-FIM series Migration](https://reader035.fdocuments.in/reader035/viewer/2022081501/568143f6550346895db08298/html5/thumbnails/1.jpg)
RS3-FIM series Migration
Don't let wiring costs prevent you from upgrading an RS3 FIM series system to a DeltaV system
This document is the property of Firelec. No copy, even partial, allowed without prior writen authorization.
![Page 2: RS3-FIM series Migration](https://reader035.fdocuments.in/reader035/viewer/2022081501/568143f6550346895db08298/html5/thumbnails/2.jpg)
RS3-FIM series Migration
Using RIAs (RS3 Interface Adapters) : • Keeping existing I/O panels• Keeping I/O termination panels and associated process I/Os• Installing RIAs (RS3 Interface Adapters) on existing FIM series termination panels
This document is the property of Firelec. No copy, even partial, allowed without prior writen authorization.
![Page 3: RS3-FIM series Migration](https://reader035.fdocuments.in/reader035/viewer/2022081501/568143f6550346895db08298/html5/thumbnails/3.jpg)
This document is the property of Firelec. No copy, even partial, allowed without prior writen
authorization.
RS3-FIM series Migration
FIM electronic module to be removed RIA to be plugged in place of existing FIM module
Using RIAs
![Page 4: RS3-FIM series Migration](https://reader035.fdocuments.in/reader035/viewer/2022081501/568143f6550346895db08298/html5/thumbnails/4.jpg)
This document is the property of Firelec. No copy, even partial, allowed without prior writen
authorization.
RS3-FIM series Migration
RS3 ControlFile
Primary PeerWay
Secondary PeerWay
Using RIAs
Communication Termination Panel
Process I/OsFIM
Process I/OsFIM
Existing RS3 architecture
![Page 5: RS3-FIM series Migration](https://reader035.fdocuments.in/reader035/viewer/2022081501/568143f6550346895db08298/html5/thumbnails/5.jpg)
This document is the property of Firelec. No copy, even partial, allowed without prior writen
authorization.
RS3-FIM series Migration
RS3 ControlFile
Primary PeerWay
Secondary PeerWay
PeerWay to be removed
Using RIAs
Communication Termination Panel
To be removed
To be removed
Process I/OsFIM
FIM to be replaced by the RIA
Process I/OsFIM
FIM to be replaced by the RIA
Devices to be removed
![Page 6: RS3-FIM series Migration](https://reader035.fdocuments.in/reader035/viewer/2022081501/568143f6550346895db08298/html5/thumbnails/6.jpg)
This document is the property of Firelec. No copy, even partial, allowed without prior writen
authorization.
RS3-FIM series Migration
Using RIAs
I/O termination panels and associated I/Os are kept in place in the existing cabinets
Process I/Os
Process I/Os
Devices to be kept
![Page 7: RS3-FIM series Migration](https://reader035.fdocuments.in/reader035/viewer/2022081501/568143f6550346895db08298/html5/thumbnails/7.jpg)
This document is the property of Firelec. No copy, even partial, allowed without prior writen
authorization.
RS3-FIM series Migration
Using RIAs
Process I/Os
Process I/Os
New DeltaV architecture
Secondary DeltaV Highway
Cnt
rl
PS
I/O
1
I/O
2
I/O
3
I/O
4
I/O
5
I/O
6I/
O7
I/O
8
Primary DeltaV Highway
![Page 8: RS3-FIM series Migration](https://reader035.fdocuments.in/reader035/viewer/2022081501/568143f6550346895db08298/html5/thumbnails/8.jpg)
RS3-FIM series Migration
The End