RRH-C2 Installation Manual
-
Upload
forwireless -
Category
Documents
-
view
275 -
download
0
Transcript of RRH-C2 Installation Manual
-
7/26/2019 RRH-C2 Installation Manual
1/31
EPNA
Ed. 01
Smart MBS RRH-C2
Installation Manual
-
7/26/2019 RRH-C2 Installation Manual
2/31
.
.
.
.
, .
.
: 3 105 3 Document Center 442-600
:http://www.samsungdocs.co.kr
Call Center .
:1588-4141
2011 SAMSUNG Electronics Co., Ltd. All rights reserved.
-
7/26/2019 RRH-C2 Installation Manual
3/31
Smart MBS RRH-P4
SAMSUNG Electronics Co., Ltd. I
Revision History
Edition Date Desciption
00 2011. 05. Initial Draft
01 2011. 09. 04 Update
Warning
Changes or modifications not expressly approved by Samsung could void the user's authority to
operate the equipment
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at his own expense.
-
7/26/2019 RRH-C2 Installation Manual
4/31
Smart MBS RRH-P4
SAMSUNG Electronics Co., Ltd. II
Table of contents
Revision History ___________________________________________________________________ I
1 .
Before Installation ________________________________________________1
1.1 System Outlook ________________________________________________________1
1.2 Cable Connection_______________________________________________________7
2 .
Installation_____________________________________________________A 1
2.1
System Installation Process ____________________________________________ A-1
2.2
RRH Installation ______________________________________________________A-3
2.2.1 Installation Diagram ______________________________________________________A-3
2.4 Mounting ____________________________________________________________A-5
2.4.1 Wall Mount Type_________________________________________________________A-5
2.4.2 Pole Mount Type_________________________________________________________A-7
2.5 RRH ~ Antenna Cable Connection ______________________________________ A-9
2.5.1 Feeder Line Connection __________________________________________________A-9
2.5.2 RET Cable Connection _________________________________________________ A-15
2.6 Frame Ground Cable Connection_______________________________________A-18
2.6.1 RRH-C2 Grounding ____________________________________________________ A-18
2.7 Connecting DC and CPRI Cable _________________________________________A-20
2.7.1 RRH-C2 Power Cable Connection________________________________________ A-20
2.7.4 RRH-C2 CPRI Cable Connection ________________________________________ A-27
F.1
Standard Torque for Bolt______________________________________________A-32
-
7/26/2019 RRH-C2 Installation Manual
5/31
Smart MBS RRH-P4
SAMSUNG Electronics Co., Ltd. 1
1. Before Installation
1.1 System OutlookRRH-C2
Fig1.1RRH-C2 Outlook
-
7/26/2019 RRH-C2 Installation Manual
6/31
1 . Error! Style not defined.
2 SAMSUNG Electronics Co., Ltd.
RRH-C2 External Interface
Fig1.2RRH-C2 External Interface
-
7/26/2019 RRH-C2 Installation Manual
7/31
Smart MBS RRH-P4 /Ed.00
SAMSUNG Electronics Co., Ltd. 3
Capacity
This is the specification of RRH-C2.
Items Specification
Air specification FDD CDMA
Operating Frequency DL: 862~ 869 MHz
UL: 817 ~ 824 MHz
Channel Bandwidth 1.25MHz/5MHz
Capacity 1.25 MHz CDMA 5Carriers
RF Power per Sector 50 W 2 T
DU~RRH-C2 Interface CPRI 4.0(Optic)
Holdover 24 hr
Input Voltage
This is the input voltage specification of RRH-C2. RRH-C2comply with UL60950 safety
regulations.
Items Specification
Input Power -48VDC
Power consumption(MAX) 10.4A (at -48V with 47dBm output power on each ANT)
19.0 A (at -38V with 48.5dBm output power on each ANT)
Size and Weight
Specification
Size(mm) RRH-C2 471(W) 269(D) 457(H)
Weight(kg) RRH-C2 Max 31 kg
-
7/26/2019 RRH-C2 Installation Manual
8/31
1 . Error! Style not defined.
4 SAMSUNG Electronics Co., Ltd.
Environment condition
Items Criteria Specification
Temperature -40~55C(without solar load) GR-487-CORE Sec. 3.26
Humidity 10~95% GR-487-CORE Sec.3.34.2
(Issue 2, April, 2002) R3-204
Altitude -60~1,800 m(-197~6,000 ft) GR-63-CORE Sec.4.1.3
Earthquake Zone 4 GR-63-CORE Sec.4.4.1
GR-487-CORE Sec.3.35.6
Vibration Office Vibration
Transportation Vibration
GR-63-CORE Sec.4.4.4
GR-487-CORE Sec.3.35.5
GR-63-CORE Sec.4.4.5
GR-487-CORE Sec.3.35.3
Noise (sound
pressure level)
With 1.5 m(5 ft) distance, 1.0 m(3 ft) Height
-
7/26/2019 RRH-C2 Installation Manual
9/31
Smart MBS RRH-P4 /Ed.00
SAMSUNG Electronics Co., Ltd. 5
1.2 Cable Connection
Fig1.3Cabling Diagram
3)RRH-C
2Groun
dCa
ble
[RF Antenna]
[MGB]
2) TGB Ground Cable
[TGB]
Fee
der
Line
Groun
dCa
ble
(Groun
dKit/w
ithover
7/8in
.Fee
der
Line
)
TGB and Ground Kit is required when over 7/8 in. Feeder
Line is used.
[Rectifier] [UADU]
4)Power
Ca
ble
1) MGB Ground Cable
5)CPRICa
ble
6) RET Cable
7) RF Cable
-
7/26/2019 RRH-C2 Installation Manual
10/31
1 . Error! Style not defined.
6 SAMSUNG Electronics Co., Ltd.
1.1RRH-C2Connecting Cable
From To Cable
MGB
(Main Ground Bar)
2) MGB Ground Cable
: AWG4/0, GV 95 mm21CFrame
Grounding TGB
(Tower Ground Bar)
2) TGB Ground Cable
: AWG4/0, GV 95 mm21C
MGB3) RRH-C2 Ground Cable
: AWG8, GV 6 mm21C
Rectifier4) Power Cable
: AWG10, 4 mm22C-1
UADU5) CPRI Cable
: Optic Cable(Single Mode)
RET 6) RET Cable Assy
,./RRH-C2
Antenna 7) RF Cable (1/2 in. or 7/8 in. Feeder Line)
-
7/26/2019 RRH-C2 Installation Manual
11/31
Smart MBS RRH-P4
SAMSUNG Electronics Co., Ltd. A-1
2. Installation
2.1 System Installation Process
Fig2.1RRH and Cabling process
Note
1.Equipment intended for installation in Restricted Access Location
2. Installation shall be in accordance with the applicable parts of Chapter 8 of ANSI/NFPA 70
RRU Grounding
Cabling in the Cabinet
Cabling the Hybri d Cable
Check
Cabling in the RRU
-
7/26/2019 RRH-C2 Installation Manual
12/31
F. Error! Style not defined.
A-2 SAMSUNG Electronics Co., Ltd.
2.2 RRH Installation
2.2.1 Installation Diagram
Fig2.2RRH-C2Installed Diagram(Pole type)
Fig2.2 RRH-C2Installed Diagram (Wall Mount type)
-
7/26/2019 RRH-C2 Installation Manual
13/31
Smart MBS RRH-P4 /Ed.00
SAMSUNG Electronics Co., Ltd. A-3
2.4 Mounting
2.4.1 Wall Mount Type
This explains how to install RRH-C2 to the wall.
1) Assemble bracket to RRH-C2(A)2) Assemble the wall mount assy to the wall. (B)
3) Install RRH-C2 to Wall mount assy(C)
Fig2.3Wall Mounting (1)
Fig2.4WallMounting (2)Wall mount Assy
`
-
7/26/2019 RRH-C2 Installation Manual
14/31
F. Error! Style not defined.
A-4 SAMSUNG Electronics Co., Ltd.
2.4.2 PoleMount Type
This explains how to install RRH-C2 to the pole
1) Assemble bracket to RRH-C2 (A)
2) Assemble the pole mount assy to the pole. (B)
3) Install RRH-C2 to the pole mount assy(C)
Fig2.6Pole Mounting (1)
Fig2.7PoleMounting (2)pole mount assy
-
7/26/2019 RRH-C2 Installation Manual
15/31
Smart MBS RRH-P4 /Ed.00
SAMSUNG Electronics Co., Ltd. A-5
2.5 RRH ~ Antenna Cable Connection
2.5.1 Feeder Line Connection
This explains how to connect cable between RRH-C2 and Antenna.
Fig2.9RRH-C2Feeder Line
RRH-
RF Antenna
A
B
-
7/26/2019 RRH-C2 Installation Manual
16/31
F. Error! Style not defined.
A-6 SAMSUNG Electronics Co., Ltd.
1) RRH-C2 RF port RF antenna 1/2 in. feeder line .
2) 1/2 in. feeder line het shrink tube(jelly type)
Din-male RRH-C2 RF port RF antenna port .
3) , heat shrink tube(jelly type) .
Fig2.10RRH-C2Feeder Line Connection 1)
-
7/26/2019 RRH-C2 Installation Manual
17/31
Smart MBS RRH-P4 /Ed.00
SAMSUNG Electronics Co., Ltd. A-7
Fig2.11RRH-C2Feeder Line Connection 2)
Antenna Connector(Din-Female)
1/2in. Feeder Line
Heat Shrink Tube(Jelly Type)
RF Antenna
Detail B
Din-Type Male Connector
for 1/2 In. Feeder Line
-
7/26/2019 RRH-C2 Installation Manual
18/31
F. Error! Style not defined.
A-8 SAMSUNG Electronics Co., Ltd.
RF
, pole
down Fig .
- : / 45
45 45
RF Antenna
-
7/26/2019 RRH-C2 Installation Manual
19/31
Smart MBS RRH-P4 /Ed.00
SAMSUNG Electronics Co., Ltd. A-9
2.5.2 RET Cable Connection tilting RET(Remote Electrical Tilting)
.
Fig2.12RETCable Connection
RETConnector(SAMWOO, SU-20SP-8P)
RET Cable
Heat Shrink Tube(Jelly Type, Black)
-
7/26/2019 RRH-C2 Installation Manual
20/31
F. Error! Style not defined.
A-10 SAMSUNG Electronics Co., Ltd.
Fig2.13RETCable Connector
2.3RETCable Connector Pin Map
Samwoo SU-20SP-8P
Pin Function
1 +12V (max 10W power consumption)3 RS485B
5 RS485A
6 +24 V (max 10W power consumption)
7 +24 V RTN
RET
1, 2, 8 NC
2.5.2 Optic Switch ConnectionThis port will not be used for this project.
-
7/26/2019 RRH-C2 Installation Manual
21/31
Smart MBS RRH-P4 /Ed.00
SAMSUNG Electronics Co., Ltd. A-11
2.6 Frame Ground Cable Connection
2.6.1 RRH-C2Grounding
RRH-C2 .
1) (AWG8, GV 6 1 C) 1 MGB RRH-C2 .
2) 6 heat shrink tube .
3) RRH-C2 ,
M6 SEMS .
Fig2.14RRH-C2Frame Ground Cable Connection
M6 x 12L SEMS
Ground Cable(AWG8, GV 6 mm21C)
From MGB(Main Ground Bar)
Detail A
Heat Shrink Tube(Green)
6 Pressure Terminal
(d2: 16 mm, 90, 2 Hole)
-
7/26/2019 RRH-C2 Installation Manual
22/31
F. Error! Style not defined.
A-12 SAMSUNG Electronics Co., Ltd.
UL ,
.
Ex) Manufacture-PanduitRRH-C2 : 6 mm2Type Name(LCD8-14AF-L)
.
Inspection Window
.
-
7/26/2019 RRH-C2 Installation Manual
23/31
Smart MBS RRH-P4 /Ed.00
SAMSUNG Electronics Co., Ltd. A-13
2.7 Connecting DC and CPRI Cable
2.7.1 RRH-C2Power Cable Connection
RRH-C2 .
1) RRH-C2 power window cover screw Torx(T15)
open .
(Cover screw cover .)
Fig2.23RRH-C2Power Cable Connection (1)
Optic0
-
7/26/2019 RRH-C2 Installation Manual
24/31
F. Error! Style not defined.
A-14 SAMSUNG Electronics Co., Ltd.
3) BasebandRack DC SPD Terminal (Hybrid cable, AWG8 or
AWG10,2C)1 RRH-C2 .
4) 70 mm
10mm .
5) .
Fig2.25RRH-C2Power Cable Connection (2)
70 mm
10 mm
DC Power Cable(AWG8 or AWG10,
11.5~15.5mm)
70 mm
DC Power Cable(AWG8 or AWG10,
11.5~15.5mm)
DC Power Cable(AWG8 or AWG10,
11.5~15.5mm)
11.5 ~
15.5mm
60 mm
-
7/26/2019 RRH-C2 Installation Manual
25/31
Smart MBS RRH-P4 /Ed.00
SAMSUNG Electronics Co., Ltd. A-15
6) cable gland nut .
7) (Hybrid cable, AWG8 or AWG10, 2C) 1
cable gland nut .
8) power window
. power cable
.
9) Power terminal block screw
, screw .
10) Cable gland nut .
Fig2.27RRH-C2Power Cable Connection (3)
11) , power window cover open
.
DC Power Cable (AWG8 or AWG10, 11.5~15.5mm)
Cable Gland Nut
-
7/26/2019 RRH-C2 Installation Manual
26/31
F. Error! Style not defined.
A-16 SAMSUNG Electronics Co., Ltd.
Circuit Breaker Installation
Required to connect to the circuit breaker for DC cable between BTS and RRH to support
stable DC supply to RRH. -48VDC circuit breaker capacity is 32A for each connection.
-
7/26/2019 RRH-C2 Installation Manual
27/31
Smart MBS RRH-P4 /Ed.00
SAMSUNG Electronics Co., Ltd. A-17
2.7.4 RRH-C2 CPRI Cable Connection
RRH-C2 UADU interface CPRI .
1) RRH-C2 optic window screw Torx(T15)
open .(Cover screw cover .)
2) optic cable gland nut .
3) Optic cable gland nut, .
4)Optic (5core, 1 ) optic optic
window optic connector SFP module .
(optic bending radius R=20mm
, .)
5) Optic connector optic cable 10mm
gland cablegland nut .
6) CPRI , window cover screw .
2.28RRH-C2CPRI Cable Connection (1)
Optic0
-
7/26/2019 RRH-C2 Installation Manual
28/31
F. Error! Style not defined.
A-18 SAMSUNG Electronics Co., Ltd.
2.5CPRI Cable
Cable Color Blue Orange Green Brown Gray
Port
Optic 0 Optic 1
(CDMA 0)
Spare Spare Spare
-
7/26/2019 RRH-C2 Installation Manual
29/31
Smart MBS RRH-P4 /Ed.00
SAMSUNG Electronics Co., Ltd. A-19
A. Standard Torque
F.1 Standard Torque for Bolt ,
.
(, , .)
F.1
Torque[kgf.cm] Torque[N.m]
M3 4.59~5.61 0.45~0.55
M4 10.98~13.42 1.08~1.32
M5 21.15~15.85 2.07~2.54
M6 38.16~46.64 3.74~4.58
M8 91.8~112.2 9.01~11.01
M10 180~220 17.66~21.58
M12 307.8~376.2 30.20~36.91
-
7/26/2019 RRH-C2 Installation Manual
30/31
F. Error! Style not defined.
B-20 SAMSUNG Electronics Co., Ltd.
B. Product Label\
-
7/26/2019 RRH-C2 Installation Manual
31/31
RRH-C2
2011 Samsung Electronics Co., Ltd.
All rights reserved.
.
.