RPS TL-UL SystemSolutions for theNorth American Solar Market

Page 2: RPS TL-UL System - Bonfiglioli · Testing-IEEE 1547.1/ IEEE C62.41.2/ IEEE C62.45/ IEEE C37.90.1/ IEEE C37.90.2 ... RPS TL-UL System DC DC DC. The RPS TL-UL inverter includes a comprehensive

Power, controland green solutions

Page 3: RPS TL-UL System - Bonfiglioli · Testing-IEEE 1547.1/ IEEE C62.41.2/ IEEE C62.45/ IEEE C37.90.1/ IEEE C37.90.2 ... RPS TL-UL System DC DC DC. The RPS TL-UL inverter includes a comprehensive

3

RPS TL-UL System

The newest product in Bonfiglioli Photovoltaics is the UL-approved RPS-TL. Leveraging the same reliable technology as its European version, the RPS TL-UL system offers a solution for the North American market that is unsurpassed in terms of proven, trusted technology.

Over 1.4 GW are currently installed globally with Bonfiglioli PV inverter technologies in large, utility-scale installations. With the addition of UL-approved inverters for the North American market, Bonfiglioli continues its commitment to solar and green technologies and strives to brighten the North American market as it has done in Europe

ReliabilityThe RPS TL-UL by Bonfiglioli is a uniquely-designed, high-powered photovoltaic inverter system that provides maximum energy harvest. With multiple, independent MPPT chanels, the RPS TL-UL ensures maximum system reliability: a single fault will affect only one subfield, while the balance of the system continues to operate, which minimizes loss of energy production.

Flexibility and ScalabilityThe RPS TL-UL boasts one of the widest ranges of inverter ratings on the market today (from 367 kWac to 1.40 MWac), ensuring an optimal matching with any size array.The fully scalable, modular architecture also offers greater design flexibility and more options for managing workload.

Quality and PerformanceBonfiglioli RPS TL-UL inverters offer the following:• A versatile design that performs well even in the

event of unexpected system failures• Lower maintenance costs and longer expected

lifetime• Top-quality electro-mechanical components reduce

the incidence of failures, which in turn reduces repair costs and increases production time.

Proven Technology and LongevitySupported by more than 40 R&D engineers and over 25 years of engineering excellence in power conversion technology, Bonfiglioli has the required footprint, experience and infrastructure to develop and deliver complete cost-effective solutions, from MPPT tracking to utility interconnection.

In addition, the overall business composition of Bonfiglioli ensures financial stability to support installations long-term, and to provide and support an uptime guarantee and wide range of extended warranty options.

Visit BonfiglioliUSA.com/PV to learn more.

RPS TL-UL from 367 kWac to 1.40 MWac

Page 4: RPS TL-UL System - Bonfiglioli · Testing-IEEE 1547.1/ IEEE C62.41.2/ IEEE C62.45/ IEEE C37.90.1/ IEEE C37.90.2 ... RPS TL-UL System DC DC DC. The RPS TL-UL inverter includes a comprehensive
Page 5: RPS TL-UL System - Bonfiglioli · Testing-IEEE 1547.1/ IEEE C62.41.2/ IEEE C62.45/ IEEE C37.90.1/ IEEE C37.90.2 ... RPS TL-UL System DC DC DC. The RPS TL-UL inverter includes a comprehensive

5

The scalable, modular architecture of the RPS TL-UL offers greater system flexibility and more options for managing working load, making Bonfiglioli an ideal partner for commercial and utility-scale installations.

Available in Master-Slave or Multi-MPPT configurations, the RPS TL-UL system includes floating or grounded arrays up to 1000Vdc.

Master-Slave ConfigurationThe Master-Slave configuration intelligently manages the working load of each module in order to maximize conversion efficiency and provide an extended working life.The automatic disconnection of individual modules during fault conditions ensures the effect on system energy production is minimized by allowing the balance of the system to operate.The Master-Slave system is ideally suited to provide the most benefit in efficiency under partial load conditions and will allow the system to start earlier in the morning and stop later in the evening.

Multi-MPPT ConfigurationThe Multi-MPPT configuration provides independent control for multiple sub-arrays, making this configuration ideally suited for solar applications with different irradiance profiles, unmatched solar panels or multiple surface slopes. In this configuration, the system is able to minimize the solar array mismatch losses by searching for the best voltage operating value that can maximize power production. This system also enables applications with different electrical characteristics to be used together, which maximizes efficiency and increases productivity.

Comprehensive Grid Management• Anti-islanding with grid voltage and frequency

protection according to UL1741 & IEEE 1547• Fault ride-through including high voltage, low

voltage and zero voltage capability.

(for more details on grid management, see page 13).

Technical Overview• Wide range of inverter power ratings from 367

kWac to 1.40 MWac• Modular inverter system with up to 7 independent

MPPT inputs• Designed to UL1741 and CSA 107.01-01 standards

(NRTL testing and certification pending)• Compliant with IEEE1547 standards• Full suite for power management functions

including Fault Ride Through• Maximum efficiency up to 98.6%• DC Load Break disconnect for each module to

provide isolation from the solar array• Includes main AC breaker to provide overall

protection for inverter lineup• Suitable for floating or grounded (positive or

negative) array configurations.

Bonfiglioli has established the assets, competence, and technical prowess to successfully deliver and install commercial and utility-scale power systems anywhere in the world.

Worldwide references70 MW - Rovigo, Italy50 MW - Puertollano, Spain60 MW - Karadzhalovo, Bulgaria200 MW - Golmud, China90 MW - Gujarat, India

RPS TL-UL System

Page 6: RPS TL-UL System - Bonfiglioli · Testing-IEEE 1547.1/ IEEE C62.41.2/ IEEE C62.45/ IEEE C37.90.1/ IEEE C37.90.2 ... RPS TL-UL System DC DC DC. The RPS TL-UL inverter includes a comprehensive

6

Master-Slave - 330V

RPS TL-UL 0367 0501 0550 0733

Input ratings

Maximum input current A 700 950 1050 1400

Maximum input voltage V 1000

MPPT range V 500 ... 875

Number of MPPT trackers - 1

# of DC collector cabinets required 1

# of fused combiner inputs 8 12 12 16

Output ratings

AC voltage V 330

AC voltage range V (%) 290 - 363 (-12% to +10%)

Frequency Hz 60

Rated power kW 367 500 550 733

Rated current A 640 875 960 1280

Power factor - nominal - >0.99 at rated power

Power factor - range - 0.9 lead to 0.9 lag

Maximum harmonic distortion (THD) % < 3 at rated power

Auxiliary power

External power (single phase) - 230V/10A 230V/10A 230V/10A 230V/10A

Losses - standby W 40 60 60 80

Efficiency

Maximum efficiency % 98.6

European weighted efficiency % 98.4

CEC weighted efficiency % 98.0 (Estimated)

Mechanical details

Dimensions (WxHxD)mm 2400x2100x800 3000x2100x800 3000x2100x800 3800x2100x800

in 94x83x31 118x83x31 118x83x31 150x83x31

Weight (approx.)kg 1550 2150 2150 2700

Ibs 3425 4750 4750 5960

Protection class - NEMA1 / IP20

Temperature

Operating ambient temperature range** °C 14°F … 122°F (-10°C ... +50°C)

Protection and monitoring

Array grounding configuration - Negative grounded / Positive grounded / Floating

Array ground fault protection - 5Amp GFDI fuse/ Impedance monitoring

Grid protection - Anti-Islanding / Adjustable voltage and frequency settings according to IEEE1547

Surge protection - UL1449, Class II on DC Input and AC Output

Interfaces

Communication interface - RS-485 (ModBus® or proprietary), Options: CAN, Profibus®

Standards & certifications

Standards - UL1741/ CSA 107.1 / IEEE 1547 (Certification Pending)

Testing - IEEE 1547.1/ IEEE C62.41.2/ IEEE C62.45/ IEEE C37.90.1/ IEEE C37.90.2

Environmental conditions - EN 60721-3-3 (3K3, 3B1, 3C2, 3S2 , 3M2)

Power management functions (optional) - LVRT, Power Factor Control, Grid Fault Support, Power / Frequency Control and Ramp Rate

**Full power rating for UDC <= 700V

Page 7: RPS TL-UL System - Bonfiglioli · Testing-IEEE 1547.1/ IEEE C62.41.2/ IEEE C62.45/ IEEE C37.90.1/ IEEE C37.90.2 ... RPS TL-UL System DC DC DC. The RPS TL-UL inverter includes a comprehensive

7

Master-Slave - 360V

RPS TL-UL 0400 0500 0600 0750 0800

Input ratings

Maximum input current A 700 950 1050 1300 1400

Maximum input voltage V 1000

MPPT range V 550 ... 875

Number of MPPT trackers - 1

# of DC collector cabinets required 1

# of fused combiner inputs 8 12 12 16 16

Output ratings

AC voltage V 360

AC voltage range V (%) 317 - 396 (-12% to +10%)

Frequency Hz 60

Rated power kW 400 500 600 750 800

Rated current A 640 800 960 1200 1280

Power factor - nominal - >0.99 at rated power

Power factor - range - 0.9 lead to 0.9 lag

Maximum harmonic distortion (THD) % < 3 at rated power

Auxiliary power

External power (single phase) - 230V/10A 230V/10A 230V/10A 230V/10A 230V/10A

Losses - standby W 40 60 60 80 80

Efficiency

Maximum efficiency % 98.6

European weighted efficiency % 98.4

CEC weighted efficiency % 98.0 (Estimated)

Mechanical details

Dimensions (WxHxD)mm 2400x2100x800 3000x2100x800 3000x2100x800 3800x2100x800 3800x2100x800

in 94x83x31 118x83x31 118x83x31 150x83x31 150x83x31

Weight (approx.)kg 1550 2150 2150 2700 2700

Ibs 3425 4750 4750 5960 5960

Protection class - NEMA1 / IP20

Temperature

Operating ambient temperature range** °C 14°F … 122°F (-10°C ... +50°C)

Protection and monitoring

Array grounding configuration - Negative grounded / Positive grounded / Floating

Array ground fault protection - 5Amp GFDI fuse/ Impedance monitoring

Grid protection - Anti-Islanding / Adjustable voltage and frequency settings according to IEEE1547

Surge protection - UL1449, Class II on DC Input and AC Output

Interfaces

Communication interface - RS-485 (ModBus® or proprietary), Options: CAN, Profibus®

Standards & certifications

Standards - UL1741/ CSA 107.1 / IEEE 1547 (Certification Pending)

Testing - IEEE 1547.1/ IEEE C62.41.2/ IEEE C62.45/ IEEE C37.90.1/ IEEE C37.90.2

Environmental conditions - EN 60721-3-3 (3K3, 3B1, 3C2, 3S2 , 3M2)

Power management functions (optional) - LVRT, Power Factor Control, Grid Fault Support, Power / Frequency Control and Ramp Rate

**Full power rating for UDC <= 700V

Page 8: RPS TL-UL System - Bonfiglioli · Testing-IEEE 1547.1/ IEEE C62.41.2/ IEEE C62.45/ IEEE C37.90.1/ IEEE C37.90.2 ... RPS TL-UL System DC DC DC. The RPS TL-UL inverter includes a comprehensive

8

Multi-MPPT - 330V

RPS TL-UL 0367 0501 0550 0733

Input ratings

Maximum input current A 700 950 1050 1400

Maximum input voltage V 1000

MPPT range V 500 ... 875

Number of MPPT trackers - 2 3 3 4

Output ratings

AC voltage V 330

AC voltage range V (%) 290 - 363 (-12% to +10%)

Frequency Hz 60

Rated power kW 367 500 550 733

Rated current A 640 875 960 1280

Power factor - nominal - >0.99 at rated power

Power factor - range - 0.9 lead to 0.9 lag

Maximum harmonic distortion (THD) % < 3 at rated power

Auxiliary power

External power (single phase) - 230V/10A 230V/10A 230V/10A 230V/10A

Losses - standby W 40 60 60 80

Efficiency

Maximum efficiency % 98.6

European weighted efficiency % 98.4

CEC weighted efficiency % 98.0 (Estimated)

Mechanical details

Dimensions (WxHxD)mm 1800x2100x800 2400x2100x800 2400x2100x800 3000x2100x800

in 71x83x31.5 95x83x31.5 95x83x31.5 118x83x31.5

Weight (approx.)kg 1300 1850 1850 2450

Ibs 2860 4070 4070 5390

Protection class - NEMA1 / IP20

Temperature

Operating ambient temperature range** °C 14°F … 122°F (-10°C ... +50°C)

Protection and monitoring

Array grounding configuration - Floating

Array ground fault protection - Impedance monitoring

Grid protection - Anti-Islanding/ Adjustable voltage and frequency settings according to IEEE1547

Surge protection - UL1449, Class II on DC Input and AC Output

Interfaces

Communication interface - RS-485 (ModBus® or proprietary), Options: CAN, Profibus®

Standards & certifications

Standards - UL1741/ CSA 107.1 / IEEE 1547 (Certification Pending)

Testing - IEEE 1547.1/ IEEE C62.41.2/ IEEE C62.45/ IEEE C37.90.1/ IEEE C37.90.2

Environmental conditions - EN 60721-3-3 (3K3, 3B1, 3C2, 3S2 , 3M2)

Supported Power Management Functions

- LVRT, Power Factor Control, Grid Fault Support, Power / Frequency Control and Ramp Rate

**Full power rating for UDC <= 700V

Page 9: RPS TL-UL System - Bonfiglioli · Testing-IEEE 1547.1/ IEEE C62.41.2/ IEEE C62.45/ IEEE C37.90.1/ IEEE C37.90.2 ... RPS TL-UL System DC DC DC. The RPS TL-UL inverter includes a comprehensive

9

Multi-MPPT - 330V

RPS TL-UL 0917 1001 1100 1283

Input ratings

Maximum input current A 1750 1900 2100 2450

Maximum input voltage V 1000

MPPT range V 500 ... 875

Number of MPPT trackers - 5 6 6 7

Output ratings

AC voltage V 330

AC voltage range V (%) 290 - 363 (-12% to +10%)

Frequency Hz 60

Rated power kW 917 1000 1100 1283

Rated current A 1600 1750 1920 2240

Power factor - nominal - >0.99 at rated power

Power factor - range - 0.9 lead to 0.9 lag

Maximum harmonic distortion (THD) % < 3 at rated power

Auxiliary power

External power (single phase) - 230V/10A 230V/10A 230V/10A 230V/10A

Losses - standby W 100 120 120 140

Efficiency

Maximum efficiency % 98.6

European weighted efficiency % 98.4

CEC weighted efficiency % 98.0 (Estimated)

Mechanical details

Dimensions (WxHxD)mm 3800x2100x800 4400x2100x800 4400x2100x800 5000x2100x800

in 150x83x31.5 173x83x31.5 173x83x31.5 197x83x31.5

Weight (approx.)kg 3000 3550 3550 4100

Ibs 6600 7810 7810 9020

Protection class - NEMA1 / IP20

Temperature

Operating ambient temperature range** °C 14°F … 122°F (-10°C ... +50°C)

Protection and monitoring

Array grounding configuration - Floating

Array ground fault protection - Impedance monitoring

Grid protection - Anti-Islanding/ Adjustable voltage and frequency settings according to IEEE1547

Surge protection - UL1449, Class II on DC Input and AC Output

Interfaces

Communication interface - RS-485 (ModBus® or proprietary), Options: CAN, Profibus®

Standards & certifications

Standards - UL1741/ CSA 107.1 / IEEE 1547 (Certification Pending)

Testing - IEEE 1547.1/ IEEE C62.41.2/ IEEE C62.45/ IEEE C37.90.1/ IEEE C37.90.2

Environmental conditions - EN 60721-3-3 (3K3, 3B1, 3C2, 3S2 , 3M2)

Supported Power Management Functions

- LVRT, Power Factor Control, Grid Fault Support, Power / Frequency Control and Ramp Rate

**Full power rating for UDC <= 700V

Page 10: RPS TL-UL System - Bonfiglioli · Testing-IEEE 1547.1/ IEEE C62.41.2/ IEEE C62.45/ IEEE C37.90.1/ IEEE C37.90.2 ... RPS TL-UL System DC DC DC. The RPS TL-UL inverter includes a comprehensive

10

Multi-MPPT - 360V

RPS TL-UL 0400 0500 0600 0750

Input ratings

Maximum input current A 700 950 1050 1300

Maximum input voltage V 1000

MPPT range V 550 ... 875

Number of MPPT trackers - 2 3 3 4

Output ratings

AC voltage V 360

AC voltage range V (%) 317 - 396 (-12% to +10%)

Frequency Hz 60

Rated power kW 400 500 600 750

Rated current A 640 800 960 1200

Power factor - nominal - >0.99 at rated power

Power factor - range - 0.9 lead to 0.9 lag

Maximum harmonic distortion (THD) % < 3 at rated power

Auxiliary power

External power (single phase) - 230V/10A 230V/10A 230V/10A 230V/10A

Losses - standby W 40 60 60 80

Efficiency

Maximum efficiency % 98.6

European weighted efficiency % 98.4

CEC weighted efficiency % 98.0 (Estimated)

Mechanical details

Dimensions (WxHxD)mm 1800x2100x800 2400x2100x800 2400x2100x800 3000x2100x800

in 71x83x31.5 95x83x31.5 95x83x31.5 118x83x31.5

Weight (approx.)kg 1300 1850 1850 2450

Ibs 2860 4070 4070 5390

Protection class - NEMA1 / IP20

Temperature

Operating ambient temperature range** °C 14°F … 122°F (-10°C ... +50°C)

Protection and monitoring

Array grounding configuration - Floating

Array ground fault protection - Impedance monitoring

Grid protection - Anti-Islanding/ Adjustable voltage and frequency settings according to IEEE1547

Surge protection - UL1449, Class II on DC Input and AC Output

Interfaces

Communication interface - RS-485 (ModBus® or proprietary), Options: CAN, Profibus®

Standards & certifications

Standards - UL1741/ CSA 107.1 / IEEE 1547 (Certification Pending)

Testing - IEEE 1547.1/ IEEE C62.41.2/ IEEE C62.45/ IEEE C37.90.1/ IEEE C37.90.2

Environmental conditions - EN 60721-3-3 (3K3, 3B1, 3C2, 3S2 , 3M2)

Supported Power Management Functions

- LVRT, Power Factor Control, Grid Fault Support, Power / Frequency Control and Ramp Rate

**Full power rating for UDC <= 700V

Page 11: RPS TL-UL System - Bonfiglioli · Testing-IEEE 1547.1/ IEEE C62.41.2/ IEEE C62.45/ IEEE C37.90.1/ IEEE C37.90.2 ... RPS TL-UL System DC DC DC. The RPS TL-UL inverter includes a comprehensive

11

Multi-MPPT - 360V

RPS TL-UL 0800 1000 1200 1400

Input ratings

Maximum input current A 1400 1750 2100 2450

Maximum input voltage V 1000

MPPT range V 550 ... 875

Number of MPPT trackers - 4 5 6 7

Output ratings

AC voltage V 360

AC voltage range V (%) 317 - 396 (-12% to +10%)

Frequency Hz 60

Rated power kW 800 1000 1200 1400

Rated current A 1280 1600 1920 2240

Power factor - nominal - >0.99 at rated power

Power factor - range - 0.9 lead to 0.9 lag

Maximum harmonic distortion (THD) % < 3 at rated power

Auxiliary power

External power (single phase) - 230V/10A 230V/10A 230V/10A 230V/10A

Losses - standby W 80 100 120 120

Efficiency

Maximum efficiency % 98.6

European weighted efficiency % 98.4

CEC weighted efficiency % 98.0 (Estimated)

Mechanical details

Dimensions (WxHxD)mm 3000x2100x800 3800x2100x800 4400x2100x800 5000x2100x800

in 118x83x31.5 150x83x31.5 173x83x31.5 197x83x31.5

Weight (approx.)kg 2450 3000 3550 4100

Ibs 5390 6600 7810 9020

Protection class - NEMA1 / IP20

Temperature

Operating ambient temperature range** °C 14°F … 122°F (-10°C ... +50°C)

Protection and monitoring

Array grounding configuration - Floating

Array ground fault protection - Impedance monitoring

Grid protection - Anti-Islanding/ Adjustable voltage and frequency settings according to IEEE1547

Surge protection - UL1449, Class II on DC Input and AC Output

Interfaces

Communication interface - RS-485 (ModBus® or proprietary), Options: CAN, Profibus®

Standards & certifications

Standards - UL1741/ CSA 107.1 / IEEE 1547 (Certification Pending)

Testing - IEEE 1547.1/ IEEE C62.41.2/ IEEE C62.45/ IEEE C37.90.1/ IEEE C37.90.2

Environmental conditions - EN 60721-3-3 (3K3, 3B1, 3C2, 3S2 , 3M2)

Supported Power Management Functions

- LVRT, Power Factor Control, Grid Fault Support, Power / Frequency Control and Ramp Rate

**Full power rating for UDC <= 700V

Page 12: RPS TL-UL System - Bonfiglioli · Testing-IEEE 1547.1/ IEEE C62.41.2/ IEEE C62.45/ IEEE C37.90.1/ IEEE C37.90.2 ... RPS TL-UL System DC DC DC. The RPS TL-UL inverter includes a comprehensive

12

0 20 40 60 80 100

99

98.5

98

97.5

97

96.5

96

95.5

95

Power (% P/Prated)

0 20 40 60 80 100

99

98.5

98

97.5

97

96.5

96

95.5

95

Power (% P/Prated)

0 20 40 60 80 100

99

98.5

98

97.5

97

96.5

96

95.5

95

Power (% P/Prated)

0 20 40 60 80 100

99

98.5

98

97.5

97

96.5

96

95.5

95

Power (% P/Prated)

Master-Slave efficiency (%) RPS TL-UL* Multi-MPPT efficiency (%) RPS TL-UL*

*Estimated

RPS TL-UL System

The modular architecture of Bonfiglioli products enables selection of the best configuration based on the characteristics of the photovoltaic plant and the site where the inverter is located.

CAAC

CCDC

CAAC

CCDC

CAAC

CCDC

CAAC

CAAC

CAAC

Master-Slave Multi-MPPT

Benefits • The earliest morning start• The later evening stop• High energy conversion efficiency• Longer expected lifetime• The lowest failure effect

Benefits• The highest energy extraction level in presence of: - Non-homogeneous light exposure - Different PV modules characteristics - Other plant conditions (dirt, cable length, etc.)• Low failure effect

86%Operational

Faulty module Faulty inverter

Modular inverter Centralized inverter

100%Power loss

Advantages of the modular configuration.

Page 13: RPS TL-UL System - Bonfiglioli · Testing-IEEE 1547.1/ IEEE C62.41.2/ IEEE C62.45/ IEEE C37.90.1/ IEEE C37.90.2 ... RPS TL-UL System DC DC DC. The RPS TL-UL inverter includes a comprehensive

13

The RPS TL-UL inverter includes a comprehensive set of grid management and protection functions with the flexibility to meet all relevant grid management codes and practices in North America. In the most standard configuration, the RPS TL-UL system includes anti-islanding with grid voltage and frequency protection according to UL1741 & IEEE 1547 to ensure that the inverter quickly and safely disconnects from the local utility.

The RPS TL-UL is also designed with a comprehensive suite of power management and grid support functions for advanced utility power plants.This capability was first developed in response to the German BDEW standards and is now offered by Bonfiglioli to meet electrical grid standards in North America.

The functions of the advanced configuration include:• Active power curtailment via SCADA interface.• Reactive power control locally or via SCADA

interface.• Fault ride-through including high voltage, low

voltage and zero voltage capability.• Dynamic grid support and voltage control

capability.• Controlled power ramps to minimize disturbances

on grid.• Compatible with FERC 661A, NERC PRC 024, WECC

ONF Plan and CAISO IRRP.

Grid Management

Vo

ltag

e

High Voltage Ridethrough

Time

Low Voltage Ridethrough

Reactive

PF

P

Q Q

Real

Available Reactive Power Control

Page 14: RPS TL-UL System - Bonfiglioli · Testing-IEEE 1547.1/ IEEE C62.41.2/ IEEE C62.45/ IEEE C37.90.1/ IEEE C37.90.2 ... RPS TL-UL System DC DC DC. The RPS TL-UL inverter includes a comprehensive

Branches and facilitiesOur branches

ITA1Bonfiglioli Riduttori S.p.A.Gearmotor assembly plantPrecison gearbox manufacturing & assembly plantVignola, Modena

BMRBonfiglioli Mechatronics ResearchBrushless motor productionRovereto, Trento

BU Industrial Headquarter BU Wind & MobileBU Regenerative & Photovoltaic

ITA2Bonfiglioli Riduttori S.p.A.Casting and gearcutting plantCalderara di Reno, Bologna

B2Bonfiglioli Riduttori S.p.A.Assembly HDP, HDO, 300 seriesCalderara di Reno, Bologna

HQBonfiglioli Riduttori S.p.A.Lippo di Calderara, Bologna

B6Bonfiglioli Riduttori S.p.A.Planetary gearboxes manufacturing & assembly plantForlì

BTPLBonfiglioli Transmission PvtGearmotors and planetary gearbox manufacturing and assembly plantChennai, India

BVNBonfiglioli VietnamElectric motor plantHo Chi Min, Vietnam

BSKBonfiglioli Slovakia SroLarge gearboxes manufacturing plantPovazska BystricaSlovakia Republic

BVBonfiglioli Vectron GmbHInverter plantKrefeld, Germany

Our production facilities

BonfiglioliCanada

BonfiglioliUSA

BonfiglioliFrance

BonfiglioliBrasil

Bonfiglioli United Kingdom

BonfiglioliSouth Africa

BonfiglioliDeutschland

BonfiglioliIndia

BonfiglioliÖsterreich

BonfiglioliSouth East Asia

BonfiglioliItalia

BonfiglioliVietnam

BonfiglioliAustralia

BonfiglioliTürkiye

BonfiglioliNew Zealand

BonfiglioliChina

Tecnotrans Bonfiglioli

Page 15: RPS TL-UL System - Bonfiglioli · Testing-IEEE 1547.1/ IEEE C62.41.2/ IEEE C62.45/ IEEE C37.90.1/ IEEE C37.90.2 ... RPS TL-UL System DC DC DC. The RPS TL-UL inverter includes a comprehensive

15

wind

photovoltaicmobile

industrial

As one of the world’s leading providers of clean energy solutions, with utility-scale PV installations currently in place around the world, Bonfiglioli has the innovative know-how and technical capacity to bring commercial and utility-scale PV power plants to life.For the PV sector, Bonfiglioli designs and manufactures highly efficient and innovative electronic control systems for photovoltaic fields and has the expertise to manage every aspect of photovoltaic energy generation from MPPT tracking to utility interconnection.

Bonfiglioli also designs and manufactures a complete range of gearmotors, drive systems and planetary gearboxes for industrial processes, automation, mobile machinery and wind energy applications.

Over 50 years of engineering excellence makes Bonfiglioli a preferred supplier and partner for market leaders around the world.For more information, visit Bonfiglioliusa.com

Bonfiglioli Solutions

Page 16: RPS TL-UL System - Bonfiglioli · Testing-IEEE 1547.1/ IEEE C62.41.2/ IEEE C62.45/ IEEE C37.90.1/ IEEE C37.90.2 ... RPS TL-UL System DC DC DC. The RPS TL-UL inverter includes a comprehensive

Bonfiglioli has been designing and developing innovative and reliable power transmission and control solutionsfor industrial, mobile machinery and renewable energyapplications since 1956.

VEC 866 R2Bonfiglioli USA3541 Hargrave Drive, Hebron, Kentucky 41048tel. (+1) 859 334 3333 - fax (+1) 859 334 8888www.bonfiglioliusa.com