RPM750 AC Drive - nebula.wsimg.com
Transcript of RPM750 AC Drive - nebula.wsimg.com
Service Address:
RPM750 AC Drive
E492603
RPM Controls11225 Valencia Blvd.Santa Clarita, CA 91381
(661) [email protected]
Performance Features
n
n
n
n
n
n
n
Advanced motor control algorithm
High performance vector control
Optimal V/F mode
Excellent ramp slope control
Fast auto-tune (less than 60 seconds)
Overload:150% rated output current, 1 minute
Low frequency torque:
0.5Hz: 100% rated torque
1Hz: 150% rated torque
Hardware Features
n
n
n
n
n
n
n
n
n
n
n
n
Dual CPU processing for precise controlStandard 5-digit LED keypad, standard RJ45
Keypad connector
5.5 kW and above have standard DC choke
22kW and below have standard internal brake IGBT
Above 22kW brake IGBT is optional
Internal EMC filter with breakpoint design, easy access and disconnection to meet different application requirements
PCBA conformal coating process, increasing environmental tolerance
Unique control terminals: simple switch between source and sink I/O terminals
Reference signal (current) loss detection
Latest generation IGBT's with efficient thermal design
Wireless fan block design for easy replacement
Optional auxiliary fan makes the drive suitable for extended temperature operation
RPM750 Series Profile
1
RPM750 AC Drive
2
0.1s Accel & Decel step response
Excellent voltage and current control
Fast torque response down to 0.5Hz in V/Hz mode
Product Overview
Mission: We will consistantly make great efforts to listen to the needs of our customers, deliver competitive solutions and services, and provide maximum
benefit and value through all products we deliver.
Excellent speed regulation
n
High temperature bus capacitors
RPM Series AC drives combine innovation and ease of use to provide motor control solutions designed to maximize your system performance and reduce your time to design and deliver better machines, Their robust design yields dependable performance in the most demanding situations. Each member of this family of drives offers a unique set of features to distinctively match the needs of your application.
RPM750 AC drives are cost-effective and easy to use for most general purpose applications. They come standard with LED Keypad, built-in I/O, the flexiility of programmable onboard logic, Modbus RTU communications, and robust power circuitry. Designed to meet your application requirements for speed or torque control up to 700 HP (550 kW).
Power and Packaging – Complete power range plus 600/690 volt availability for global applications. Packaging options range from flexible enclosure ratings(Nema 3R, 12, 4X, etc.) to complete power and control options such as:
Circuit breaker, disconnect, and fuse protectionForced air or Air Conditioner coolingLine Reactors and EMI FiltersWide variety of operator devicesCommunications optionsTurnkey Pump Panel SolutionsVFD Bypass (auto or manual)Harmonic mitigation and verification testingComplete custom control systems combining VFD's with PLC's and HMI's
Powerful performance. Application Flexible. Exceptional Value.
Demanding Applications Pump Control Integrated Systems
Performance Features
n
n
n
n
n
n
n
Advanced motor control algorithm
High performance vector control
Optimal V/F mode
Excellent ramp control
Fast auto-tune (less than 60 seconds)
Overload:150% rated output current, 1 minute
Low frequency torque:
0.5Hz: 100% rated torque
1Hz: 150% rated torque
Hardware Features
n
n
n
n
n
n
n
n
n
n
n
n
Dual CPU processing for precise controlStandard 5-digit LED keypad, standard RJ45
Keypad connector
5.5 kW and above have standard DC choke
22kW and below have standard internal brake IGBT
Above 22kW brake IGBT is optional
Internal EMC filter with breakpoint design, easy access and disconnection to meet different application requirements
PCBA conformal coating process, increasing environmental tolerance
Unique control terminals: simple switch between source and sink I/O terminals
Reference signal (current) loss detection
Latest generation IGBT's with efficient thermal design
Wireless fan block design for easy replacement
Optional auxiliary fan makes the drive suitable for extended temperature operation
RPM Series Profile
1
RPM750 AC Drive
2
0.1s Accel & Decel step response
Excellent voltage and current control
Fast torque response down to 0.5Hz in V/Hz mode
Product Overview
Mission: We will consistantly make great efforts to listen to the needs of our customers, deliver competitive solutions and services, and provide maximum
benefit and value through all products we deliver.
Excellent speed regulation
n
High temperature bus capacitors
RPM Series AC drives combine innovation and ease of use to provide motor control solutions designed to maximize your system performance and reduce your time to design and deliver better machines, Their robust design yields dependable performance in the most demanding situations. Each member of this family of drives offers a unique set of features to distinctively match the needs of your application.
RPM750 AC drives are cost-effective and easy to use for most general purpose applications. They come standard with LED Keypad, built-in I/O, the flexiility of programmable onboard logic, Modbus RTU communications, and robust power circuitry. Designed to meet your application requirements for speed or torque control up to 550 kW/700 Hp.
Power and Packaging – Complete power range plus 600/690 volt availability for global applications. Packaging options range from flexible enclosure ratings(Nema 3R, 12, 4X, etc.) to complete power and control options such as:
Circuit breaker, disconnect, and fuse protectionForced air or Air Conditioner coolingLine Reactors and EMI FiltersWide variety of operator devicesCommunications optionsTurnkey Pump Panel SolutionsVFD Bypass (auto or manual)Harmonic mitigation and verification testingComplete custom controlv systems combining VFD's with PLC's and HMI's
Powerful performance. Application Flexible. Exceptional Value.
Logic Diagram
3 4
Functions and Featuresn
n
l
l
l
l
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
l
l
l
l
n
n
n
n
Balance of powerful functionality and ease of use.
Powerful platform makes user programming easierBuilt-in advanced function blocks:
2 threshold control blocks
2 logic control blocks
3 variable selectors
brake logic control block
Programmable I/O terminals
Internal energy meter for calculating energy savings
Low DC voltage operation mode (380-480V products
can function on 220V incoming power supply )
Stop mode can be controlled when power is off
AVR
Switching frequency auto adjustment to prevent overtemp Catch spinning motor function
Injection braking
Skip frequency function
Configurable keypad disconnect faultPowerful electronic potentiometer function to adjust
reference digitallyStandard serial comms. and optional fieldbus Comprehensive protection functions:
Fast output short detection and protection Overcurrent & Overload protectionOvervoltage & Undervoltage protectionPhase loss detection and protection
Overtemp (heatsink and IGBT junction) detection Auxilliary external tripMotor thermal protection
Selectable warning display16 preset speeds (selected via control terminals) PID control
User defined V/F curves:
3 point line setting
1.2 law curve
1.7 law curve
2.0 law curve
Automatic sleep mode
Textile function
Pulse counting
Length control
Frequency (f)
Time (t)
Preset textile frequency
P14.03
Low limit of textile frequency
Centre of textile frequency
P14.02
High limit Of textile frequency
Jump frequencyAw*P14.06
Run time of preset textile frequency
P14.04
Ⅰ
Triangle rise timeP14.07*P14.08
Textile periodP14.07
+Aw
-AwⅠ
Ⅱ
Ⅱ
Run
Pause textileP14.09
Stop
Textile profile running curve
V/F curve multi section setting
F1 F2 F3 Fb Frequency Hz
V1
V2
V3
Voltage %
V1~V3: Multi section VF the 1~3 section voltage percentage
F1~F3: Multi section VF the 1~3 section frequency points
100%
Product OverviewControl logic diagram helps user understand and set parameters.
f1
f2
f3
f4
f14
f15
f16
Run
Frequency(f)
Time(t)
f1
f2
f3
f4
f14
f15f16
f1
f2
f3
f4
f14
f5~f13 f5~f13 f5~f13
Stop
The second cycleThe first cycle
16 speed profile running
Output voltage
Output frequency
Vmax
fb
0
3
2
1
Motor V/F curve
PID controller overview diagram
Analog inputs and outputs overview diagram
RPM750 AC Drive
Preset speed
0mA-20mA
P08.02 (AI1 Mode)
20mA-0mA
4mA-20mA (With trip)
20mA-4mA (With trip)
Preset speed4mA-20mA
20mA-4mA
0-10V (6)
(5)
(4)
(3)
(2)
(1)
(0)
P08.17 (AI1 level)Shows the level of AI1
P08.05 (AI1 scaling)
Used to scale AI1
P08.06 (AI1 invert)
AI1 signal invert
P08.03 (AI1 function select)
This parameter is used to decide the function of AI1
P08.01 (AI function level control)
Basic range
Can be set to extended
group parameters
(1)
(0)
Preset speed
Speed control
Torque control
Torque offset (2)
(1)
(0)
Preset speedP1.01 - P15.22
P08.18(AI2 level)Shows the level of AI2
P08.10(AI2 scaling)
Used to scale AI2
P08.11 (AI2 invert)
AI2 signal invert
P08.08 (AI2 function select)
Used to decide the function of AI2
P08.01 (AI function level control)
Basic range
Can be set to extended
group parameters
(1)
(0)
Preset speed
Speed control
Torque control
Torque offset (2)
(1)
(0)
Preset speedP1.01 - P15.22
P08.09(AI2 offset)
Offset applied to AI2 signal
P08.04(AI1 offset)
Offset applied to AI1 signal
P08.19(AO1 level)Shows the
level of AO1
P08.15(AO1 scaling)
Used to scale AO1
Preset speed
Output freq
P08.14 (AO1 function select)
Ref freq
Tor prod I
Output current
Preset speedMotor speed
DC bus voltage
Output voltage(6)
(5)
(4)
(3)
(2)
(1)
(0)
AI1 level
Preset speedAI2 level
Lengh
Counting (10)
(9)
(8)
(7)
P1.01 - P15.22
P08.13(AO function level control)
Basic range
Can be set to extended
group parameters
(1)
(0)
AO1
AI1
AI2
P08.20(AI1 Upper limit)
P08.21 (AI1 Lower limit)
Error
P15.07 (PID enable)
OFF
On (1)
(0)
P12.01 (Drive healthy)
Not healthy
Healthy (1)
(0)
P1.01 - P15.22
P15.02 (PID feedback) P15.20
(PID feedback level)
Displayed in %
P15.05 (PID feedback invert)
Not inverted
Inverted (1)
(0)
P1.01 - P15.22
P15.01 (PID reference)
P15.19 (PID ref level)Displayed in %
P15.04 (PID reference invert)
Not inverted
Invert (1)
(0) P15.21 (PID error level)Displayed in %
roportional
ntegral
erivative
P
I
DP15.11
P15.10
P15.09
+
+
+ P15.22 (PID
output level)Displayed in %
P15.14 (PID output
scaling) P1.01 - P15.22
P15.15(PID output function)
P1.01 - P15.22
P15.03 (PID feed forward reference)
+
++
-
P15.12(Max Output)
P15.13(Min Output)
P15.18(PID feed forward
ref level)Displayed in %
P15.16 (PID integrator hold)
OFF
On (1)
(0)
P10.21 (PID output freeze)
OFFOn
(1)
(0)
Logic Diagram
3 4
Functions and Featuresn
n
l
l
l
l
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
l
l
l
l
n
n
n
n
Balance of powerful functionality and ease of use. Powerful platform makes user programming easierBuilt-in advanced function blocks:
2 threshold control blocks
2 logic control blocks
3 variable selectors
brake logic control block
Programmable I/O terminals
Internal energy meter for calculating energy savings
Low DC voltage operation mode (380-480V products can
funtion on 220V incoming power supply )
Stop mode can be controlled when power is off
AVR
Switching frequency auto adjustment to prevent overtempCatch spinning motor function
Injection braking
Skip frequency function
Configurable keypad disconnect faultPowerful electronic potentiometer function to adjust
reference digitallyStandard serial comms. and optional fieldbus Comprehensive protection functions:
Fast output short detection and protection Overcurrent & Overload protectionOvervoltage & Undervoltage protectionPhase loss detection and protection
Overtemp (heatsink and IGBT junction) detection Auxilliary external tripMotor thermal protection
Selectable warning display16 preset speeds (selected via control terminals) PID control
User defined V/F curves:
3 point line setting
1.2 law curve
1.7 law curve
2.0 law curve
Automatic sleep mode
Textile function
Pulse counting
Length control
Frequency (f)
Time (t)
Preset textile frequency
P14.03
Low limit of textile frequency
Centre of textile frequency
P14.02
High limit Of textile frequency
Jump frequencyAw*P14.06
Run time of preset textile frequency
P14.04
Ⅰ
Triangle rise timeP14.07*P14.08
Textile periodP14.07
+Aw
-AwⅠ
Ⅱ
Ⅱ
Run
Pause textileP14.09
Stop
Textile profile running curve
V/F curve multi section setting
F1 F2 F3 Fb Frequency Hz
V1
V2
V3
Voltage %
V1~V3: Multi section VF the 1~3 section voltage percentage
F1~F3: Multi section VF the 1~3 section frequency points
100%
Product OverviewControl logic diagram helps user understand and set parameters.
f1
f2
f3
f4
f14
f15
f16
Run
Frequency(f)
Time(t)
f1
f2
f3
f4
f14
f15f16
f1
f2
f3
f4
f14
f5~f13 f5~f13 f5~f13
Stop
The second cycleThe first cycle
16 speed profile running
Output voltage
Output frequency
Vmax
fb
0
3
2
1
Motor V/F curve
PID controller overview diagram
Analog inputs and outputs overview diagram
RPM750 AC Drive
Preset speed
0mA-20mA
P08.02 (AI1 Mode)
20mA-0mA
4mA-20mA (With trip)
20mA-4mA (With trip)
Preset speed4mA-20mA
20mA-4mA
0-10V (6)
(5)
(4)
(3)
(2)
(1)
(0)
P08.17 (AI1 level)Shows the level of AI1
P08.05 (AI1 scaling)
Used to scale AI1
P08.06 (AI1 invert)
AI1 signal invert
P08.03 (AI1 function select)
This parameter is used to decide the function of AI1
P08.01 (AI function level control)
Basic range
Can be set to extended
group parameters
(1)
(0)
Preset speed
Speed control
Torque control
Torque offset (2)
(1)
(0)
Preset speedP1.01 - P15.22
P08.18(AI2 level)Shows the level of AI2
P08.10(AI2 scaling)
Used to scale AI2
P08.11 (AI2 invert)
AI2 signal invert
P08.08 (AI2 function select)
Used to decide the function of AI2
P08.01 (AI function level control)
Basic range
Can be set to extended
group parameters
(1)
(0)
Preset speed
Speed control
Torque control
Torque offset (2)
(1)
(0)
Preset speedP1.01 - P15.22
P08.09(AI2 offset)
Offset applied to AI2 signal
P08.04(AI1 offset)
Offset applied to AI1 signal
P08.19(AO1 level)Shows the
level of AO1
P08.15(AO1 scaling)
Used to scale AO1
Preset speed
Output freq
P08.14 (AO1 function select)
Ref freq
Tor prod I
Output current
Preset speedMotor speed
DC bus voltage
Output voltage(6)
(5)
(4)
(3)
(2)
(1)
(0)
AI1 level
Preset speedAI2 level
Lengh
Counting (10)
(9)
(8)
(7)
P1.01 - P15.22
P08.13(AO function level control)
Basic range
Can be set to extended
group parameters
(1)
(0)
AO1
AI1
AI2
P08.20(AI1 Upper limit)
P08.21 (AI1 Lower limit)
Error
P15.07 (PID enable)
OFF
On (1)
(0)
P12.01 (Drive healthy)
Not healthy
Healthy (1)
(0)
P1.01 - P15.22
P15.02 (PID feedback) P15.20
(PID feedback level)
Displayed in %
P15.05 (PID feedback invert)
Not inverted
Inverted (1)
(0)
P1.01 - P15.22
P15.01 (PID reference)
P15.19 (PID ref level)Displayed in %
P15.04 (PID reference invert)
Not inverted
Invert (1)
(0) P15.21 (PID error level)Displayed in %
roportional
ntegral
erivative
P
I
DP15.11
P15.10
P15.09
+
+
+ P15.22 (PID
output level)Displayed in %
P15.14 (PID output
scaling) P1.01 - P15.22
P15.15(PID output function)
P1.01 - P15.22
P15.03 (PID feed forward reference)
+
++
-
P15.12(Max Output)
P15.13(Min Output)
P15.18(PID feed forward
ref level)Displayed in %
P15.16 (PID integrator hold)
OFF
On (1)
(0)
P10.21 (PID output freeze)
OFFOn
(1)
(0)
General Technical Data
Input power
Input voltage Vin
200V (– ) 240V (+ ) 1/3 PH
380V (–10%)~480V (+10%) 3PH
500V (–10%)~690V (+10%) 3PH
10% ~ 10%
Input frequency 50Hz/60Hz(±2Hz)
Maximum supply imbalance
≤3%
Power outputOutput voltage 0V~Vin
Output frequency 0Hz~300Hz
Performance specifications
Voltage control V/F, Sensorless Vector Control
Switching frequency 1kHz~15kHz
Speed range Sensorless vector control -1:100, V/F mode -1:50
Starting torque 0.5Hz: 100% rated torque
1Hz: 150% rated torque
Torque accuracy 5%
Reference resolution Digital- 0.01Hz, Analog- 0.1%×Maximum frequency
Accel. & Decel. rate 0.1s~3600min
Voltage boost 0.1 30.0%~ %
OverloadE & G type: 150% rated output current for 1 minute P type: 110% rated output current for 1 minute
V/F 4 types: V/F (user programmable) and ramp (2.0 power, 1.7 power, 1.2 power)
DC injectionInjection frequency: 0.0% 0.0% maximum frequency
Injection current: 0.0%~300.0% rated current
Injection time: 0.00s~60.00s
~10
Dynamic braking Dynamic braking utilization rate: 0.0%~100.0%
JogJog frequency: 0.00Hz maximum frequency
Jog acceleration rate: 0.1s~600.0s
Jog interval time: 0.1s~600.0s
~
Preset 16 preset speeds (determined via control terminals)
AVR Maintains rated output voltage when the input power supply voltage changes
Special function
Textile Textile machine control
Simple PLC Onboard PLC and speed profile
Length control Winding control
PID control Process control (reference closed loop control)
Advanced function blocks
2 logic control blocks
1 binary selector
2 threshold control blocks
3 variable selectors
5 6
Control terminal
Reference sourceDigit: Keypad, motorized pot (E-Pot), pulse, comms.
Analog: AI1: 0V 10V, 0(4) mA~20mA;
AI2: 0V~10V
~
Operating mode Keypad, Control terminal, Serial comms.
Digital input terminals
DI1 DI7: Programmable terminals use DI6 as pulse input, 0Hz~60Hz; Use DI7 forhigh frequency pulse input (1Hz~50.0kHz) or PTC thermistor input
~
Digital output terminals
DO1 DO2: Programmable terminals, Max. output current: 50mA, Use DO2 for providing
output pulse ( 0.1kHz~50.0kHz ), and output PWM
~
Analog output Terminals
A 1: programmable terminal, 0V 10VO ~
Status relay
2 programmable relays, contactor data: AC250V/2A (resistive load)
AC250V/1A (inductive load)
DC30V/1A
Comms.Connector 2 terminals (A&B) and RJ45 port
Protocol Modbus RTU
Environment
Altitude1000m rated
1000m~3000m, derate current 1% per 100m
Operating temperature
−10℃~+40℃
Maximum humidity < 90% relative humidity, non-condensing
Vibration 2 ≤5.9m/s (0.6g)
Storage temperature
− +40℃~ 70℃
Running environment
Indoor, non-flammable, non corrosive, free from electrically conductive material,
keep fan unrestricted
Optional modulesLCD Keypad, HDOM-232, HDOM-USB, Profibus module, Keypad pallet, HDSOFT (PCTools),
etc.
ProtectionOutput short, overcurrent, overload, overvoltage, undervoltage, phase loss, overtemp
(heatsink and junction), external trip, etc.
Efficiency1.5kW and below: 89%
2.2kW~22kW: ≥93%
30kW and above: ≥95%
≥
Mounting method Surface mounting, through hole, cubicle standing
Enclosure IP 20, IP21 (by adding optional device)
Cooling method 220V/ 0.4kW model is convection cooled, all others are forced air cooled
General Technical Data
RPM750 AC Drive
FLASH test platformDT test platform PCBA ATE test platform
General Technical Data
Input power
Input voltage Vin
200V (– ) 240V (+ ) 1/3 PH
380V (–10%)~480V (+10%) 3PH
500V (–10%)~690V (+10%) 3PH
10% ~ 10%
Input frequency 50Hz/60Hz(±2Hz)
Maximum supply imbalance
≤3%
Power outputOutput voltage 0V~Vin
Output frequency 0Hz~300Hz
Main performance function
Voltage control V/F, Open loop Vector Control
Switching frequency 1kHz~15kHz
Speed range Open loop vector control -1:100, V/F mode -1:50
Starting torque 0.5Hz: 100% rated torque
1Hz: 150% rated torque
Torque accuracy 5%
Reference resolution Digital- 0.01Hz, Analog- 0.1%×Maximum frequency
Accel. & Decel. rate 0.1s~3600min
Voltage boost 0.1 30.0%~ %
OverloadE & G type: 150% rated output current for 1 minute P type: 110% rated output current for 1 minute
V/F 4 types: V/F (user programmable) and ramp (2.0 power, 1.7 power, 1.2 power)
DC injectionInjection frequency: 0.0% 0.0% maximum frequency
Injection current: 0.0%~300.0% rated current
Injection time: 0.00s~60.00s
~10
Dynamic braking Dynamic braking utilization rate: 0.0%~100.0%
JogJog frequency: 0.00Hz maximum frequency
Jog acceleration rate: 0.1s~600.0s
Jog interval time: 0.1s~600.0s
~
Preset 16 preset speeds (determined via control terminals)
AVR Maintains rated output voltage when the input power supply voltage changes
Special function
Textile Textile machine control
Simple PLC Onboard PLC and speed profile
Length control Winding control
PID control Process control (reference closed loop control)
Advanced function blocks
2 logic control blocks
1 binary selector
2 threshold control blocks
3 variable selectors
5 6
Control terminal
Reference sourceDigit: Keypad, motorized pot (E-Pot), pulse, comms.
Analog: AI1: 0V 10V, 0(4) mA~20mA;
AI2: 0V~10V
~
Operating mode Keypad, Control terminal, Serial comms.
Digital input terminals
DI1 DI7: Programmable terminals use DI6 as pulse input, 0Hz~60Hz; Use DI7 forhigh frequency pulse input (1Hz~50.0kHz) or PTC thermistor input
~
Digital output terminals
DO1 DO2: Programmable terminals, Max. output current: 50mA, Use DO2 for providing
output pulse ( 0.1kHz~50.0kHz ), and output PWM
~
Analog output Terminals
A 1: programmable terminal, 0V 10VO ~
Status relay
2 programmable relays, contactor data: AC250V/2A (resistive load)
AC250V/1A (inductive load)
DC30V/1A
Comms.Connector 2 terminals (A&B) and RJ45 port
Protocol Modbus RTU
Environment
Altitude1000m rated
1000m~3000m, derate current 1% per 100m
Operating temperature
−10℃~+40℃
Maximum humidity < 90% relative humidity, non-condensing
Vibration 2 ≤5.9m/s (0.6g)
Storage temperature
− +40℃~ 70℃
Running environment
Indoor, non-flammable, non corrosive, free from electrically conductive material,
keep fan unrestricted
Optional modulesLCD Keypad, RPM-232, RPM-USB, Profibus module, Keypad adapter, RPMSoft (PCTools),
etc.
ProtectionOutput short, overcurrent, overload, overvoltage, undervoltage, phase loss, overtemp
(heatsink and junction), external trip, etc.
Efficiency1.5kW and below: 89%
2.2kW~22kW: ≥93%
30kW and above: ≥95%
≥
Mounting method Surface mounting, through hole, cubicle standing
Enclosure IP 20, IP21 (by adding optional device)
Cooling method 220V/ 0.4kW model is convection cooled, all others are forced air cooled
General Technical Data
RPM750 AC Drive
220V Rating Data Power supply: 200Vac~240Vac +/-10%, 50Hz/60Hz, single/three phase
Model Name Default Carrier Frequency (kHz)
Drive Power Size kVA)(
Rated Input Current A( ) Rated Output Current A( )
Motor Power (HP) Size
1/3PHRPM750-20D00028 6 1.1 7.1/ 4 2.8 0.5 ARPM750-20D00050 6 1.9 12.8/ 7.1 5 1.0 ARPM750-20D00080 6 3.0 20.5/ 11.3 8 2.0 ARPM750-20D00110 6 4.2 24/ 14.5 11 3.0 BRPM750-20T00176 6 6.7 16.5 17.6 5 C
7 8
480V Rating Data690V Rating Data
Model Reference 480V Rating Data RPM750 - 4 0 T 0095
Heavy Duty Rated Amps
0095: 9.5 Amps
Input phaseD: 1/3PHT: 3PH
Family
Supply voltage2: 220V4: 380V-480V6: 690V
Brake IGBT0: Internally fitted1: None
Blank: standard G type E: reduced frame size G type P: reduced frame size P type
RPM750 AC Drive
Power supply: 380Vac~480Vac +/-10%, 50Hz/60Hz, three phase
Model NameDefault Carrier
Frequency (KHz)
G P
SizeDrive Power Size(kVA)
Rated Input
Current(A)
Rated Output Current
(A)
Motor Power(HP)
Drive Power Size(kVA)
Rated Input
Current(A)
Rated Output Current
(A)
Motor Power(HP)
RPM750-40T00025 6 1.7 3.6 2.5 1.0 − − − − ARPM750-40T00042 6 2.8 5.7 4.2 2.0 − − − − ARPM750-40T00052E 6 3.4 6.1 5.2 3.0 − − − − ARPM750-40T00058 6 3.8 8.3 5.8 3.0 − − − − BRPM750-40T00095 6 6.3 13.2 9.5 5.0 − − − − BRPM750-40T00130E 6 8.6 14.3 13 7.5 − − − − BRPM750-40T00130P 6 − − − − 8.6 14.3 13 7.5 BRPM750-40T00130 6 8.6 12.4 13 7.5 − − − − CRPM750-40T00170 6 11 16.1 17 10 − − − − CRPM750-40T00230P 6 − − − − 15.2 21 23 15 CRPM750-40T00250 6 16.5 24 25 15 21 31 32 20 DRPM750-40T00320 6 21 31 32 20 25 36 38 25 DRPM750-40T00380 6 25 36 38 25 30 44 46 30 ERPM750-40T00460 6 30 44 46 30 40 58 60 40 ERPM750-40T00600E 3 40 58 60 40 50 72 75 50 E1RPM750-40T00750E 3 50 72 75 50 − − − − E1RPM750-40T00600 3 40 58 60 40 50 72 75 50 FRPM750-40T00750 3 50 72 75 50 63 93 96 60 F
Power supply: 380Vac~480Vac +/-10%, 50Hz/60Hz, three phase
Model NameDefault Carrier
Frequency (KHz)
G P
SizeDrive Power Size(kVA)
Rated Input
Current(A)
Rated Output Current
(A)
Motor Power(HP)
Drive Power Size(kVA)
Rated Input
Current(A)
Rated Output Current
(A)
Motor Power(HP)
RPM750-40T00960 3 63 93 96 60 83 121 125 75 FRPM750-40T01250 3 83 121 125 75 103 151 156 100 FRPM750-40T01560 3 103 151 156 100 119 175 180 125 FRPM750-40T01800 3 119 175 180 125 139 204 210 150 GRPM750-40T02100 3 139 204 210 150 169 248 256 200 GRPM750-40T02560 3 169 248 256 200 205 301 310 250 GRPM750-40T03100E 3 205 301 310 250 231 340 350 250 JRPM750-40T03500E 3 231 340 350 250 255 375 387 300 JRPM750-40T03870E 3 255 375 387 300 280 415 427 350 JRPM750-40T03100 3 205 301 310 250 231 340 350 250 KRPM750-40T03500 3 231 340 350 250 255 375 387 300 KRPM750-40T03870 3 255 375 387 300 310 4 75 4 17 350 KRPM750-40T04710 3 310 4 75 4 17 350 343 505 5 02 400 KRPM750-40T05200 3 343 505 5 02 400 403 592 610 500 KRPM750-40T06100 2 403 592 610 500 444 653 673 550 LRPM750-40T06730 2 444 653 673 550 495 728 750 600 LRPM750-40T07500 2 495 728 750 600 551 810 835 700 LRPM750-40T08350 2 551 810 835 700 622 915 943 800 L
Power supply: 500Vac 690Vac, 50Hz/60Hz, three phase~
Model NameDefault Carrier
Frequency (KHz)
G P
SizeDrive Power Size(kVA)
Rated Input
Current(A)
Rated Output Current
(A)
Motor Power(HP)
Drive Power Size(kVA)
Drive Power Size(kVA)
Rated Output Current
(A)
Motor Power(HP)
RPM750-60T00360 3 43 36 36 30 51 49 51 37 FRPM750-60T00510 3 61 49 51 37 65 52 54 45 FRPM750-60T00540 3 65 52 54 45 75 61 63 55 FRPM750-60T00630 3 75 61 63 55 103 83 86 75 FRPM750-60T00860 3 103 83 86 75 120 97 100 90 FRPM750-60T01000 3 120 97 100 90 157 127 131 110 GRPM750-60T01310 3 157 127 131 110 179 145 150 132 GRPM750-60T01500 3 179 145 150 132 209 170 175 160 GRPM750-60T01750E 3 209 170 175 160 237 192 198 185 JRPM750-60T01980E 3 237 192 198 185 276 224 231 200 JRPM750-60T02310EE
3 276 224 231 200 296 235 248 220 JRPPM750-60T01750 3 209 170 175 160 237 192 198 185 KRPM750-60T01980 3 237 192 198 185 276 224 231 200 KRPM750-60T02310 3 276 224 231 200 327 266 274 250 KRPM750-60T02740 3 327 266 274 250 350 285 293 280 KRPM750-60T02930 3 350 285 293 280 392 318 328 315 KRPM750-60T03280 2 392 318 328 315 462 375 387 355 LRPM750-60T03870 2 462 375 387 355 509 413 426 400 LRPM750-60T04260 2 509 413 426 400 576 468 482 450 LRPM750-60T04820 2 576 468 482 450 651 529 545 500 L
Power size of RPM750 refers to a standard 4 pole induction motor at rated voltage. E & G: Heavy duty P: Normal duty Overload of E & G type: 150% rated output current, 1 minute Overload of P type: 110% rated output current, 1 minute
220V Rating Data Power supply: 200Vac~240Vac +/-10%, 50Hz/60Hz, single/three phase
Model Name Default Carrier Frequency (kHz)
Drive Power Size kVA)(
Rated Input Current A( ) Rated Output Current A( )
Motor Power (HP) Size
1/3PHRPM750-20D00028 6 1.1 7.1/ 4 2.8 0.5 ARPM750-20D00050 6 1.9 12.8/ 7.1 5 1.0 ARPM750-20D00080 6 3.0 20.5/ 11.3 8 2.0 ARPM750-20D00110 6 4.2 24/ 14.5 11 3.0 BRPM750-20T00176 6 6.7 16.5 17.6 5 C
7 8
480V Rating Data 690V Rating Data
Model Reference 480V Rating DataRPM750 - 4 0 T 0095
Heavy Duty Rated Amps
0095: 9.5 Amps
Input phaseD: 1/3PHT: 3PH
Family
Supply voltage2: 220V4: 380V-480V6: 690V
Brake IGBT0: Internal fitted1: None
Blank: standard G typeE: reduced frame size G type P: reduced frame size P type
RPM750 AC Drive
Power supply: 380Vac~480Vac +/-10%, 50Hz/60Hz, three phase
Model NameDefault Carrier
Frequency (KHz)
G P
SizeDrive Power Size(kVA)
Rated Input
Current(A)
Rated Output Current
(A)
Motor Power(HP)
Drive Power Size(kVA)
Rated Input
Current(A)
Rated Output Current
(A)
Motor Power(HP)
RPM750-40T00025 6 1.7 3.6 2.5 1.0 − − − − ARPM750-40T00042 6 2.8 5.7 4.2 2.0 − − − − ARPM750-40T00052E 6 3.4 6.1 5.2 3.0 − − − − ARPM750-40T00058 6 3.8 8.3 5.8 3.0 − − − − BRPM750-40T00095 6 6.3 13.2 9.5 5.0 − − − − BRPM750-40T00130E 6 8.6 14.3 13 7.5 − − − − BRPM750-40T00130P 6 − − − − 8.6 14.3 13 7.5 BRPM750-40T00130 6 8.6 12.4 13 7.5 − − − − CRPM750-40T00170 6 11 16.1 17 10 − − − − CRPM750-40T00230P 6 − − − − 15.2 21 23 15 CRPM750-40T00250 6 16.5 24 25 15 21 31 32 20 DRPM750-40T00320 6 21 31 32 20 25 36 38 25 DRPM750-40T00380 6 25 36 38 25 30 44 46 30 ERPM750-40T00460 6 30 44 46 30 40 58 60 40 ERPM750-40T00600E 3 40 58 60 40 50 72 75 50 E1RPM750-40T00750E 3 50 72 75 50 − − − − E1RPM750-40T00600 3 40 58 60 40 50 72 75 50 FRPM750-40T00750 3 50 72 75 50 63 93 96 60 F
Power supply: 380Vac~480Vac +/-10%, 50Hz/60Hz, three phase
Model NameDefault Carrier
Frequency (KHz)
G P
SizeDrive Power Size(kVA)
Rated Input
Current(A)
Rated Output Current
(A)
Motor Power(HP)
Drive Power Size(kVA)
Rated Input
Current(A)
Rated Output Current
(A)
Motor Power(HP)
RPM750-40T00960 3 63 93 96 60 83 121 125 75 FRPM750-40T01250 3 83 121 125 75 103 151 156 100 FRPM750-40T01560 3 103 151 156 100 119 175 180 125 FRPM750-40T01800 3 119 175 180 125 139 204 210 150 GRPM750-40T02100 3 139 204 210 150 169 248 256 200 GRPM750-40T02560 3 169 248 256 200 205 301 310 250 GRPM750-40T03100E 3 205 301 310 250 231 340 350 250 JRPM750-40T03500E 3 231 340 350 250 255 375 387 300 JRPM750-40T03870E 3 255 375 387 300 280 415 427 350 JRPM750-40T03100 3 205 301 310 250 231 340 350 250 KRPM750-40T03500 3 231 340 350 250 255 375 387 300 KRPM750-40T03870 3 255 375 387 300 310 4 75 4 17 350 KRPM750-40T04710 3 310 4 75 4 17 350 343 505 5 02 400 KRPM750-40T05200 3 343 505 5 02 400 403 592 610 500 KRPM750-40T06100 2 403 592 610 500 444 653 673 550 LRPM750-40T06730 2 444 653 673 550 495 728 750 600 LRPM750-40T07500 2 495 728 750 600 551 810 835 700 LRPM750-40T08350 2 551 810 835 700 622 915 943 800 L
Power supply: 500Vac 690Vac, 50Hz/60Hz, three phase~
Model NameDefault Carrier
Frequency (KHz)
G P
SizeDrive Power Size(kVA)
Rated Input
Current(A)
Rated Output Current
(A)
Motor Power(kW)
Drive Power Size(kVA)
Drive Power Size(kVA)
Rated Output Current
(A)
Motor Power(kW)
RPM750-60T00360 3 43 36 36 30 51 49 51 37 FRPM750-60T00510 3 61 49 51 37 65 52 54 45 FRPM750-60T00540 3 65 52 54 45 75 61 63 55 FRPM750-60T00630 3 75 61 63 55 103 83 86 75 FRPM750-60T00860 3 103 83 86 75 120 97 100 90 FRPM750-60T01000 3 120 97 100 90 157 127 131 110 GRPM750-60T01310 3 157 127 131 110 179 145 150 132 GRPM750-60T01500 3 179 145 150 132 209 170 175 160 GRPM750-60T01750E 3 209 170 175 160 237 192 198 185 JRPM750-60T01980E 3 237 192 198 185 276 224 231 200 JRPM750-60T02310EE
3 276 224 231 200 296 235 248 220 JRPPM750-60T01750 3 209 170 175 160 237 192 198 185 KRPM750-60T01980 3 237 192 198 185 276 224 231 200 KRPM750-60T02310 3 276 224 231 200 327 266 274 250 KRPM750-60T02740 3 327 266 274 250 350 285 293 280 KRPM750-60T02930 3 350 285 293 280 392 318 328 315 KRPM750-60T03280 2 392 318 328 315 462 375 387 355 LRPM750-60T03870 2 462 375 387 355 509 413 426 400 LRPM750-60T04260 2 509 413 426 400 576 468 482 450 LRPM750-60T04820 2 576 468 482 450 651 529 545 500 L
Power size of RPM750 refers to a standard 4 pole induction motor at rated voltage. E & G: Heavy duty P: Normal duty Overload of E & G type: 150% rated output current, 1 minute Overload of P type: 110% rated output current, 1 minute
109
Mounting Dimensions Mechanical Dimensions
RPM750 AC Drive
Keypad Control
PROG. MODE
W
W1 DØ
Ø
HH1
Size A, B, C
ØW
W1D
D1
H H1
Ø
Size E1, F
WW1
W2
Ø
H H1
D
D1
Ø
Size G
D
WW1
W2
Ø
Ø
H1
H
Size D, E
Size J Size K Size L
WW1
W2
H H1
D
D1
Ø
Ø
Size Model Name W(mm)
W1(mm)
W2(mm)
H(mm)
H1(mm)
D(mm)
D1(mm)
MountingHole
Ø(mm)Weight
(kg) Comments
A
RPM750-20D00028
97.4 80 – 202.4 190 148.8 – 5 1.4 –
RPM750-20D00050RPM750-20D00080
RPM750-40T00025RPM750-40T00042RPM750-40T00052E
B
RPM750-20D00110
142.4 123.5 – 220.4 208 155.5 – 5 2.2 –
RPM750-40T00058RPM750-40T00095RPM750-40T00130E
RPM750-40T00130P
C
RPM750-20D00176
163.1 142 – 300 280 176.8 – 6 4.5 Internal DC chokeRPM750-40T00130
RPM750-40T00170
RPM750-40T00230P
DRPM750-40T00250
238.5 184 92 370 356.5 189 – 7 8.8 Internal DC chokeRPM750-40T00320
ERPM750-40T00380
238.5 184 92 435.5 422 200.3 – 7 12.1 Internal DC chokeRPM750-40T00460
E1RPM750-40T00600E
320 210 – 510 490 226 222.5 8 20 –RPM750-40T00750E
F
RPM750-40T00600
355.5 221 – 573 552.5 315.5 310 10 40
Internal DC choke
RPM750-40T00750 Internal DC choke
RPM750-40T00960 Internal DC choke
RPM750-40T01250 External DC choke
RPM750-40T01560 External DC choke
RPM750-60T00360 Internal DC choke
RPM750-60T00510 Internal DC choke
RPM750-60T00540 Internal DC choke
RPM750-60T00630 External DC choke
RPM750-60T00860 External DC choke
G
RPM750-40T01800
445.6 340 170 725 701.5 355 349.5 10 63 External DC choke
RPM750-40T02100
RPM750-40T02560
RPM750-60T01000
RPM750-60T01310
RPM750-60T01500
J
RPM750-40T03100E
575.5 440 220 937 889 379.3 373.8 13 104 External DC choke
RPM750-40T03500E
RPM750-40T03870E
RPM750-60T01750ERPM750-60T01980ERPM750-60T02310E
K
RPM750-40T03100
640 520 175 1246.5 1207.5 405.5 400 13 150 External DC choke
RPM750-40T03500
RPM750-40T03870
RPM750-40T04710RPM750-40T05200
RPM750-60T01750
RPM750-60T01980
RPM750-60T02310
RPM750-60T02740
RPM750-60T02930
H
W D
WW1
W2
D
D1
H H1
Ø
Ø
109
Mounting Dimensions Mechanical Dimensions
RPM750 AC Drive
Keypad Control
PROG. MODE
W
W1 DØ
Ø
HH1
Size A, B, C
ØW
W1D
D1
H H1
Ø
Size E1, F
WW1
W2
Ø
H H1
D
D1
Ø
Size G
D
WW1
W2
Ø
Ø
H1
H
Size D, E
Size J Size K Size L
WW1
W2
H H1
D
D1
Ø
Ø
Size Model Name W(mm)
W1(mm)
W2(mm)
H(mm)
H1(mm)
D(mm)
D1(mm)
MountingHole
Ø(mm)Weight
(kg) Comments
A
RPM750-20D00028
97.4 80 – 202.4 190 148.8 – 5 1.4 –
RPM750-20D00050RPM750-20D00080
RPM750-40T00025RPM750-40T00042RPM750-40T00052E
B
RPM750-20D00110
142.4 123.5 – 220.4 208 155.5 – 5 2.2 –
RPM750-40T00058RPM750-40T00095RPM750-40T00130E
RPM750-40T00130P
C
RPM750-20D00176
163.1 142 – 300 280 176.8 – 6 4.5 Internal DC chokeRPM750-40T00130
RPM750-40T00170
RPM750-40T00230P
DRPM750-40T00250
238.5 184 92 370 356.5 189 – 7 8.8 Internal DC chokeRPM750-40T00320
ERPM750-40T00380
238.5 184 92 435.5 422 200.3 – 7 12.1 Internal DC chokeRPM750-40T00460
E1RPM750-40T00600E
320 210 – 510 490 226 222.5 8 20 –RPM750-40T00750E
F
RPM750-40T00600
355.5 221 – 573 552.5 315.5 310 10 40
Internal DC choke
RPM750-40T00750 Internal DC choke
RPM750-40T00960 Internal DC choke
RPM750-40T01250 External DC choke
RPM750-40T01560 External DC choke
RPM750-60T00360 Internal DC choke
RPM750-60T00510 Internal DC choke
RPM750-60T00540 Internal DC choke
RPM750-60T00630 External DC choke
RPM750-60T00860 External DC choke
G
RPM750-40T01800
445.6 340 170 725 701.5 355 349.5 10 63 External DC choke
RPM750-40T02100
RPM750-40T02560
RPM750-60T01000
RPM750-60T01310
RPM750-60T01500
J
RPM750-40T03100E
575.5 440 220 937 889 379.3 373.8 13 104 External DC choke
RPM750-40T03500E
RPM750-40T03870E
RPM750-60T01750ERPM750-60T01980ERPM750-60T02310E
K
RPM750-40T03100
640 520 175 1246.5 1207.5 405.5 400 13 150 External DC choke
RPM750-40T03500
RPM750-40T03870
RPM750-40T04710RPM750-40T05200
RPM750-60T01750
RPM750-60T01980
RPM750-60T02310
RPM750-60T02740
RPM750-60T02930
H
W D
WW1
W2
D
D1
H H1
Ø
Ø
Typical Wiring
PE
Drive fault +24V
L3
FWD
REV
Jog WD
Preset select bit0
Preset select bit1
DI1
DI2
DI3
DI4
DI5
DI6
DI7
0V
+10V
AI2
AI1
0V
0V~10V
M
AO1
0V
Output frequency Analog output 0V~10V
DO1
DO2
0V
Zero apeed +24V
RL1
RL2
RL3
RL4
L1
L2
L3/N
U
V
W
24V User +24V
+DC +DC1 - DCBR
DC choke
Motor
CN3
CN2
Keypad connector
Option connector
Coast Stop
Reset
Common
PEPE
RPM750
Supply1/3 PH
AB
485 terminals
RJ45 port
Healthy= closed
Drive active= closed
Brake resistor
Pro
gra
mm
able
L1
L2
0V~10V/0(4)mA~20mA
Note:
n All the programmable control terminal functions are factory default set;
n For analog control wire use shielded cable or shielded twisted pair;
n 5.5kW~ 280kW models (including 220V/4kW, except size E1 models), internal DC choke is fitted. 315kW~ 450kW
models with AC reactor fitted.
11 12
RPM750 AC Drive
Control Terminals
RL3 RL4 DO224VAI20V DI4 DI5 BADI7DI6
RL1 RL2 AO110VAI10V DO1 24V DI3DI2DI10V
RS485
Control Terminal Diagram
Control TerminalsAnd Communication PortType Terminal Name Function Technical Specification
Serial comms.
RS485 RJ45 port Two lines, Modbus RTU protocol
A 485 plus signalSame function with RJ45 port, mainly for multi network
B 485 minus signal
Digit input
DI1 DI5~Programmable digital input terminals
Active can be 0V or 24V by setting the P09.21 (default is 0V) Input resistance: 10kΩHigh logic threshold: 10V±1VSample time: 1ms
DI6Dedicated digital input Length counting Number counting
l Same as DI1 DI5l Length counting by input pulse Sample time: 5msl Number counting by input pulse Sample time: 5msNote: pulse frequency range is 0Hz~60Hz
~
DI7Dedicated digital inputHigh frequency pulse input Motor thermister input
l Same as DI1~DI5 Except Input resistance is 5k l High frequency pulse input Frequency range: 1kHz~50kHz l Program P09.21=1 for thermister input
Trip resistance: 3kΩ Reset resistance: 1.8kΩ Sample time: 5ms
Ω
Digital output
DO1Programmable digital output terminal 1
Output: 24V/0VMaximum output current: 50mA Update rate: 20ms
DO2Programmable digital output terminal 2
l Same as DO1l High frequency pulse output (0.1kHz~50kHz) l PWM output (10kHz)
Analog input & output
AI1Programmable analog input1
0V 10V, Input resistance: 100k , 0 (4) mA 20mALoad resistance:188Ω, Minimum potentiometer resistance: 0.5kΩResolution: 0.1%, Accuracy: 2%, Sampling period: 5ms
~ Ω ~
AI2Programmable analog input1
0V 10V, Input resistance: 30kMinimum potentiometer resistance: 0.5kΩResolution: 0.1%, Accuracy: 2%Sampling period: 5ms
~ Ω
AO1Programmable analog output
0V 10V, Maximum output current: 5mA, Resolution: 0.4%Accuracy: ±5%, Update rate: 5ms
~
Power supply & Relay
10V Analog reference +10V Accuracy: 2%, Maximum output current: 20mA
24V User supply (2) Accuracy: ±15%, Maximum output current: 100mA
0V Common (3) Common reference point for control signals
RL1 RL2,Programmable Relay1 output contact
Type: normally open Update rate: 5msContact rating:250VAC/2A(resistive); 250VAC/1A(inductive); 30VDC/1A Default:Relay1: closed when powered and healthyRelay2: closed when drive is active
RL3 RL4,Programmable Relay2 output contact
Size Model Name W(mm)
W1(mm)
W2(mm)
H(mm)
H1(mm)
D(mm)
D1(mm)
MountingHole
Ø(mm)Weight
(kg) Comments
L
RPM750-40T06100
804 – – 2200 – 804 – – 350 Internal AC choke
RPM750-40T06730
RPM750-40T07500
RPM750-40T08350
RPM750-60T03280
RPM750-60T03870RPM750-60T04260
RPM750-60T04820
Mechanical Dimensions
Typical Wiring
PE
Drive fault +24V
L3
FWD
REV
Jog WD
Preset select bit0
Preset select bit1
DI1
DI2
DI3
DI4
DI5
DI6
DI7
0V
+10V
AI2
AI1
0V
0V~10V
M
AO1
0V
Output frequency Analog output 0V~10V
DO1
DO2
0V
Zero apeed +24V
RL1
RL2
RL3
RL4
L1
L2
L3/N
U
V
W
24V User +24V
+DC +DC1 - DCBR
DC choke
Motor
CN3
CN2
Keypad connector
Option connector
Coast Stop
Reset
Common
PEPE
RPM750
Supply1/3 PH
AB
485 terminals
RJ45 port
Healthy= closed
Drive active= closed
Brake resistor
Pro
gra
mm
able
L1
L2
0V~10V/0(4)mA~20mA
Note:
n All the programmable control terminal functions are factory default set;
n For analog control wire use shielded cable or shielded twisted pair;
n 5.5kW~ 280kW models (including 220V/4kW, except size E1 models), internal DC choke is fitted. 315kW~ 450kW
models with AC reactor fitted.
11 12
RPM750 AC Drive
Control Terminals
RL3 RL4 DO224VAI20V DI4 DI5 BADI7DI6
RL1 RL2 AO110VAI10V DO1 24V DI3DI2DI10V
RS485
Control Terminal Diagram
Control Terminals And Communication PortType Terminal Name Function Technical Specification
Serial comms.
RS485 RJ45 port Two lines, Modbus RTU protocol
A 485 plus signalSame function with RJ45 port, mainly for multi network
B 485 minus signal
Digit inputs
DI1 DI5~Programmable digital input terminals
Active logic level can be 0V or 24V by setting the P09.21 (default is 0V) Input resistance: 10kΩHigh logic threshold: 10V±1VSample time: 1ms
DI6Dedicated digital input Length counting Number counting
l Same as DI1 DI5l Length counting by input pulse Sample time: 5msl Number counting by input pulse Sample time: 5msNote: pulse frequency range is 0Hz~60Hz
~
DI7Dedicated digital inputHigh frequency pulse input Motor thermister input
l Same as DI1~DI5 Except Input resistance is 5k l High frequency pulse input Frequency range: 1kHz~50kHz l Program P09.21=1 for thermister input Trip resistance: 3kΩ Reset resistance: 1.8kΩ Sample time: 5ms
Ω
Digital output
DO1Programmable digital output terminal 1
Output: 24V/0VMaximum output current: 50mA Update rate: 20ms
DO2Programmable digital output terminal 2
l Same as DO1l High frequency pulse output (0.1kHz~50kHz) l PWM output (10kHz)
Analog input & output
AI1Programmable analog input1
0V 10V, Input resistance: 100k , 0 (4) mA 20mALoad resistance:188Ω, Minimum potentiometer resistance: 0.5kΩResolution: 0.1%, Accuracy: 2%, Sampling period: 5ms
~ Ω ~
AI2Programmable analog input1
0V 10V, Input resistance: 30kMinimum potentiometer resistance: 0.5kΩResolution: 0.1%, Accuracy: 2%Sampling period: 5ms
~ Ω
AO1Programmable analog output
0V 10V, Maximum output current: 5mA, Resolution: 0.4%Accuracy: ±5%, Update rate: 5ms
~
Power supply & Relay
10V Analog reference +10V Accuracy: 2%, Maximum output current: 20mA
24V User supply (2) Accuracy: ±15%, Maximum output current: 100mA
0V Common (3) Common reference point for control signals
RL1 RL2,Programmable Relay1 output contact
Type: normally open Update rate: 5msContact rating:250VAC/2A(resistive); 250VAC/1A(inductive); 30VDC/1A Default:Relay1: closed when powered and healthyRelay2: closed when drive is active
RL3 RL4,Programmable Relay2 output contact
Size Model Name W(mm)
W1(mm)
W2(mm)
H(mm)
H1(mm)
D(mm)
D1(mm)
MountingHole
Ø(mm)Weight
(kg) Comments
L
RPM750-40T06100
804 – – 2200 – 804 – – 350 Internal AC choke
RPM750-40T06730
RPM750-40T07500
RPM750-40T08350
RPM750-60T03280
RPM750-60T03870RPM750-60T04260
RPM750-60T04820
Mechanical Dimensions
13 14
Service Items1. Warranty exchange service
2. Field maintenance or Repair/Return3. Spare parts supply services4. Technical support via phone or email5. Expert on site technical support service
6. Industry system solutions support
7. Professional technical training
Options
RPM750 AC Drive
Quality Assurance & Reliability (CE/UL Certification)
E348255
LCD keypad Remote keypad Profibus module Keypad adapter
RPM-232 RPM-USB RPMSOFT (PCTools) RPM-IO-Logic
Note: If there is a conflict with parameter content, pressing the key will not allow advancing to the next parameter.
Keys Function Description
In any display level, pressing the ESC key will return to the previous level. Holding the key will display the value
odisplay parameter determined by P05.01. When the Keypad is locked, holding the ESC key for 5 seconds will unlock.
Programmable key, it can function as Jog, Fwd./Rev., or coast stop by setting P05.07. Default function is jog.
Enter next level of the keypad display.
When in keypad control mode (P00.03 or P10.07=0), pressing this key will initiate drive run.
This key will stop the drive unless the keypad is locked. Resets drive faults unless locked.
INC/DEC: Used to select parameters and edit their values. In keypad run mode, they are used to
increase and decrease the speed of the motor.
l Pressing this key in run/stop mode wil cycle display through output frequency, reference frequency, output current,
output voltage, DC bus voltage in order.l In parameter edit mode, pressing this key will change the selected digit of the parameter value.
KeypadLCD Keypad
Keypad Function
Meets C3 without external EMC filter.
Meets the following standards:EC/EN
13 14
Service Items1. Warranty exchange service
2. Field maintenance or Repair/Return3. Spare parts supply services4. Technical support via phone or email5. Expert on site technical support service
6. Industry system solutions support
7. Professional technical training
Options
RPM750 AC Drive
Quality Assurance & Reliability (CE/UL Certification)
E492603
LCD keypad Remote keypad Profibus module Keypad adapter
RPM-232 RPM-USB RPMSOFT (PCTools) RPM-IO-Logic
Note: If there is a conflict with parameter content, pressing the key will not allow advancing to the next parameter.
Keys Function Description
In any display level, pressing the ESC key will return to the previous level. Holding the key will display the value
odisplay parameter determined by P05.01. When the Keypad is locked, holding the ESC key for 5 seconds will unlock.
Programmable key, it can function as Jog, Fwd./Rev., or coast stop by setting P05.07. Default function is jog.
Enter next level of the keypad display.
When in keypad control mode (P00.03 or P10.07=0), pressing this key will initiate drive run.
This key will stop the drive unless the keypad is locked. Resets drive faults unless locked.
INC/DEC: Used to select parameters and edit their values. In keypad run mode, they are used to
increase and decrease the speed of the motor.
l Pressing this key in run/stop mode wil cycle display through output frequency, reference frequency, output current,
output voltage, DC bus voltage in order.l In parameter edit mode, pressing this key will change the selected digit of the parameter value.
KeypadLCD Keypad
Keypad Function
Meets C3 without external EMC filter.
Meets the following standards:EC/EN
Service Address:
RPM750 AC Drive
E348255
RPM Controls25876 The Old RoadSuite 503 Stevenson Ranch, CA 91381
(800) [email protected]
RPM CONTROLS