Replacement Parts List No. 700013700 Revision AQ 02/2018 Daikin McQuay Roofpak™ Applied Rooftop Units Standard & Digital Scroll Compressor Models RPS, RDT, RFS, RCS 045 - 079 Tons Vintage D Unit Model Code 44= R, D To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.DaikinApplied.com

Transcript of RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D,...

Page 1: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Replacement Parts List No. 700013700 Revision AQ 02/2018

DaikinMcQuay

Roofpak™Applied Rooftop Units

Standard & Digital Scroll Compressor Models

RPS, RDT, RFS, RCS045 - 079 Tons

Vintage D Unit Model Code 44= R, D

To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.DaikinApplied.com

Page 2: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 2

ContentsParts List Revision History ...................................................................................................................................................... 5Nomenclature ...................................................................................................................................................................... 6- 14Electrical Legend .............................................................................................................................................................. 15- 18Section A1- Outdoor/Return Air Section Notes ................................................................................................................................................................................ 19 100% Outside Air Damper with Hood- No Return Air Plenum .......................................................................................... 20 100% Outside Air Damper Detail w/ ACT3 ................................................................................................................ 21, 22 0- 30% Outside Air Section w/ ACT3 ........................................................................................................................... 23, 24 0- 100% Economizer Section with Exhaust Damper- Units w/o Return Air Fans ............................................................. 25 0- 100% Economizer Section with Exhaust Damper- Units w/ 40” Return Air Fans......................................................... 26 0- 100% Economizer Section with Prop Exhaust Fan & Damper .................................................................................... 27 0- 100% Economizer Damper w/ ACT3- Diagrams ......................................................................................................... 28 0- 100% Economizer Damper w/ ACT3- Components ..................................................................................................... 29 California Title 24 Assembly: Code 33 (Mid 2012 & Later) = *F*** ................................................................................... 30 Return Air Plenum Isolation Damper w/ Actuator ACT6 .................................................................................................. 31 Prop Exhaust Fan & Damper Detail .......................................................................................................................... 32- 34 Design Flow Detail ........................................................................................................................................................... 35 40” Return Air Fan: Code 21= 40B* ................................................................................................................................. 36 Return Air Fan Mounts: Code 21= 40B* ........................................................................................................................... 37 Return Air Fan Motors ................................................................................................................................................ 38, 39 Section Mounted Controls- OAE, RAE, LT11, S11, REC11 .............................................................................................. 40Section A2- Outdoor/Return Air w/ Heat Recovery Section Notes ............................................................................................................................................................................... 41 Cabinet Gaskets, Doors, Hardware, Exhaust Hoods ....................................................................................................... 42 Base Components, Hood, Dampers................................................................................................................................. 43 40” Return Air Fan Detail ............................................................................................................................................ 44- 47 Low Leak Damper Detail ................................................................................................................................................. 48 Bypass “L” Type Damper Detail ....................................................................................................................................... 49 Heat Recovery/Enthalpy Wheel, Motor, Drive Components, Seals.................................................................................. 50 AFD60 Frost Protection Inverter: Code 24= F ................................................................................................................. 51 Section Mounted Controls- OAE, RAE, RAT, EAT, LAT .................................................................................................... 52 Section Mounted Controls- SD2, HUM1, LT11, S11, REC11 ........................................................................................... 53Section B- DrawThru Filter/Blank Section Notes ............................................................................................................................................................................... 54 Section Mounted Controls- PC5, LT13, S13, REC13 ...................................................................................................... 54 Filters ............................................................................................................................................................................... 55 Air Blender Section Components .................................................................................................................................... 56 Magnehelic/Differential Pressure Gauges ....................................................................................................................... 56Section C- DrawThru Blank Access Section OR Separate Inverter Section Notes ............................................................................................................................................................................... 57 Section Mounted Controls- LT21, S21, REC21 ............................................................................................................... 57Section D- DrawThru Cooling Section Notes ............................................................................................................................................................................... 58 24” Section, Small Face Coils .......................................................................................................................................... 59 48” Section, Large Face Coils .......................................................................................................................................... 59Section E- Spacer Section & Section E- DrawThru Heat Section Notes ............................................................................................................................................................................... 60 Section Mounted Controls- LT18, REC18, S18- Section Mounted Light ......................................................................... 60 Hot Water OR Steam Coil Heat, Mixing Valves & Actuator VM1 ...................................................................................... 61Section F- Supply Air Section Notes ............................................................................................................................................................................... 62 Forward Curved Fans- Low Pressure- FCLP .................................................................................................................. 63 Forward Curved Fans- High Pressure- FCMP ................................................................................................................. 64 Air Foil Fan- Double Width ............................................................................................................................................... 65 Air Foil Fan- Single Width- RDT Units ............................................................................................................................. 66 Fan Mounts- 27” Forward Curved Fan ............................................................................................................................ 67 Fan Mounts- 27” Airfoil Double Width Fan ..................................................................................................................... 68 Fan Mounts- 30” Airfoil Double Width Fan ...................................................................................................................... 69 Fan Mounts- 33” Airfoil Double Width Fan ....................................................................................................................... 70 Fan Mounts- 40” AFSW- RDT Units ................................................................................................................................ 71 Fan Mounts- 44” AFSW- RDT Units ................................................................................................................................ 72

Page 3: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 3

ContentsContinued

Section F- Supply Air Section, Continued Supply Air Fan Motors ............................................................................................................................................... 73, 74 Belt Guards ...................................................................................................................................................................... 75 Inverters & Inverter Bypass Control Box Motor HP 2- 5 ........................................................................................................................................................ 76, 77 Motor HP 7.5- 25 ................................................................................................................................................... 78- 81 Motor HP 30- 50 ..................................................................................................................................................... 82- 85 Inverters ................................................................................................................................................................ 86- 90 Line Reactors ............................................................................................................................................................... 91 Section Mounted Controls- PC7, HL22, LT10, S10, REC10, UV Lights ........................................................................... 92 Section Mounted Controls- MAT, EFT, SAT, DAT, OAT, SD1 ............................................................................................. 93 Section Mounted Controls- SCB- Split Junction Box- TB25, TB27, TB28, PB10, PB9, PB20, PB19 .............................. 94Section G- BlowThru Heat Section Notes ............................................................................................................................................................................... 95 Option 1: Blank/Empty Section Diffuser ........................................................................................................................................................................ 95 Option 2: Hot Water OR Steam Coil Heat Mixing Valves and Actuator VM1 ................................................................................................................................. 96 Option 3: Electric Heat Heaters, Diffusers, Hi Limit Cutouts HL1- 20, 31- 50 ............................................................................................ 97, 98 Electric Heat Control Box- 03/13 & Earlier .......................................................................................................... 99- 103 Electric Heat Control Box- 04/13 & Later .......................................................................................................... 104- 108 Option 4- Gas Heat Heat Exchangers & Vestibules- 200, 250 MBH Furnaces ........................................................................................ 109 Heat Exchangers & Vestibules- 320, 400, 500, 640, 650, 790, 800, 1000 MBH Furnaces ....................................... 110 Modulating Burner .............................................................................................................................................. 111- 113 Hi Turn Down Burner ..........................................................................................................................................114- 117 Modulating Burner Controls No Controls- Diagram ........................................................................................................................................... 118 No Controls- Components .................................................................................................................................... 119 MicroTech III Controls .......................................................................................................................................... 120 Hi Turn Down Burner Controls No Controls- Diagram .......................................................................................................................................... 121 No Controls- Components ................................................................................................................................... 122 MicroTech III Controls .......................................................................................................................................... 123 Gas Train- Inlet ................................................................................................................................................. 124- 126 Gas Train- Controls: GV1,GV2, GV3, GV4, GV5, GV6, VM1 ........................................................................... 127- 129 Gas Train- Outlet ...................................................................................................................................................... 130 Gas Train- Damper Linkage ...................................................................................................................................... 131 Cabinet Doors, Gasketing, Hardware, and Flue Box Mounting ........................................................................ 132, 133Section H- BlowThru Heat Blank Access Section Notes ............................................................................................................................................................................. 134 Access Door Latching Assemblies, Key, & Lock (All Sections) ..................................................................................... 134Section I- BlowThru Cooling Section Notes ............................................................................................................................................................................. 135 Section Mounted Controls- LT16, S16, REC16 ............................................................................................................. 135Section J- Final Filter Section Notes ............................................................................................................................................................................. 136 Section Mounted Controls- HL23, PC6 ......................................................................................................................... 136 Filters ..................................................................................................................................................................... 137, 138Section K- Discharge Plenum Section- RPS OR RFS Notes ............................................................................................................................................................................. 139 Section Mounted Controls- OAT, DAT, SD1 ................................................................................................................... 139 Discharge Damper Assembly w/ Actuator ACT5 ........................................................................................................... 140Section L- Out-of-Airstream Blank Access Section Notes ............................................................................................................................................................................. 141 Section Mounted Controls- LT20, REC20, S20 ............................................................................................................. 141Section M- Condenser Section Notes ..................................................................................................................................................................... 142, 143 Condenser Fan Deck Assembly- 045- 068D: Code 47= 1, 2 ................................................................................ 144, 145 Condenser Fan Deck Assembly- 070- 079D: Code 47= 1, 2 ................................................................................. 146, 147 Quiet Fan Assembly: Code 47= 3, 4 ............................................................................................................................. 148

Page 4: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 4

ContentsContinued

Section M- Condenser Section, Continued Standard Compressors & Compressor Components: Code 44=R OR D Unit Size 045D .......................................................................................................................................................... 149 Unit Size 050, 051D .................................................................................................................................................. 150 Unit Size 060- 063D .................................................................................................................................................. 151 Unit Size 068D .......................................................................................................................................................... 152 Unit Size 070- 079D .................................................................................................................................................. 153 Digital Compressors & Components: Code 44= R AND Code 60= XX OR Code 44= D ....................................... 154, 155 RCS Pressure Manifolds- PC13, PC23, HP1, HP2, LP1, LP2, SPTRL ................................................................. 156, 157 RPS/RDT Pressure Controls Box- AFD11, AFD21, LR11, LR21, LP1, LP2, HP1, HP2 ......................................... 158- 161 RCS Condenser Control Box ................................................................................................................................ 162- 165 Factory Supplied Line Voltage Box- T6, DS6, FU6A, FU6B, FU6C ............................................................................... 166Section N- Main Control Box Notes ............................................................................................................................................................................. 167 Control Box Component Label Diagram......................................................................................................................... 168 Control Panel Units with No Controller: Code 12= Y* ............................................................................................................. 169, 170 Control Panel: (03/13 & Earlier) MicroTech III Units with Controller: Code 12= *E, *F, *W ................................................................................. 171- 173 Control Panel: (04/2013 & Later) MicroTech III Units with Controller: Code 12= *E, *F, *W ................................................................................. 174- 176 Power Panel: (03/13 & Earlier) Power Panel Diagram ............................................................................................................................................... 177 Terminal Blocks, T1 Transformer & Fusing ............................................................................................................... 178 Fusing, Phase Protection, Ground Fault, Power Blocks ........................................................................................... 179 Power Blocks continued, Receptacle, Disconnect Switch DS1 ........................................................................ 180, 181 Disconnect Switch DS2, Circuit Breakers CB10, 20 ................................................................................................. 182 Circuit Breakers CB10, 20 continued, Plugs ............................................................................................................ 183 Supply MMP10 & M10 Fan Contactor and Return MMP20 & M20 Fan Contactor ........................................... 184- 188 Compressor MMP1- 4 and Contactor M1- 4 Unit Size 045D .................................................................................................................................................... 189 Unit Sizes 050D, 051 ........................................................................................................................................... 190 Unit Sizes 060D- 063D ........................................................................................................................................ 191 Unit Size 068D .................................................................................................................................................... 192 Unit Sizes 070, 071D ........................................................................................................................................... 193 Unit Size 075D .................................................................................................................................................... 194 Unit Size 079D .................................................................................................................................................... 195 Condenser Fan Contactors, MMPs, & Fusing .................................................................................................. 196, 197 Heat Recovery Wheel MMP60 and Contactor M60 .................................................................................................. 198 Power Panel: (04/2013 & Later) Power Panel Diagram ............................................................................................................................................... 199 Terminal Blocks, T1 Transformer & Fusing ............................................................................................................... 200 Fusing, Phase Protection, Ground Fault, Power Blocks ............................................................................................ 201 Power Blocks, continued, Receptacle, Plugs ........................................................................................................... 202 Disconnect Switch DS1, 2 ........................................................................................................................................ 203 Supply MMP10 & M10 Fan Contactor, Return MMP20 & M20 Fan Contactor Diagrams ........................................ 204 Supply and Return Fan Contactors, Circuit Breakers, & Fusing Components .................................................. 205- 211 Compressor Motor Protector MMP1- 4, & Contactor M1- 4 Unit Size 045D ..................................................................................................................................................... 212 Unit Size 050, 051D ............................................................................................................................................. 213 Unit Size 060- 063D ............................................................................................................................................. 214 Unit Size 068D ..................................................................................................................................................... 215 Unit Size 070, 071D ........................................................................................................................................... 216 Unit Size 075D .................................................................................................................................................... 217 Unit Size 079D ............................................................................................................................................. 218, 219 Condenser Fan Contactors, MMPs, & Fusing .................................................................................................. 220, 221 Energy Recovery Wheel Contactors, MMPs, & Fusing ............................................................................................ 222 Intelligent Equipment ...................................................................................................................................................... 223 Section O- Refrigeration Tubing Notes ............................................................................................................................................................................ 224 Refrigeration Tubing Diagram ....................................................................................................................................... 224 Valves, Filter Driers, Sight Glasses, & Hot Gas Bypass/Liquid Line Kits .............................................................. 225, 226 Hot Gas Reheat.............................................................................................................................................................. 227

Page 5: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 5

Parts List Revision History Rev. Date Description A- AM 04/16 Archived Revisions A thru AG. AN 06/17 Page 7- 13: Misc. updates/corrections/additions. Page 15- 18: Added misc. descriptions to Legend. Page 19, 41, 52, 57, 58, 60, 135, 136, 142, 223 (OLD) 19, 41, 54, 59, 60, 62, 135, 136, 142, 222 (NEW): Rewrote Notes. Page 26: Updated dwg. Changed Bub # “11” to “160”. Rewrote pg. header. Corrected dmpr. coding. Updated the TOC. Page 27: Updated dwgs. Changed bub. for Ref # “6” Fan Assy. to Ref # “420” per BOM. Added Grd. Fan Assys. Page 32: Updated Fan/hood dwg. Changed Bub # “6” to “420” & “6A” to “420A”. Added Grd. Fan Assys. Page 34: Rewrote footnote & Updated footnote notation. Page 35: Added “JE, JY” to pg. header. Added Note. Page 36, 37: Swapped pg. positions. Rewrote pg. headers. Updated the TOC. Page 37: Updated dwg. Removed unused VIV Fan info & updated p/n table & coding. Page 38, 73: Corrected coding. Page 40, 50 (OLD) 40, 52 (NEW): Rewrote footnote # 2. Page 43: Corrected Ref. #230 description. Page 46, 47 (NEW): Added pgs. for 1/12 & Later 40” SAF. Repaginated form & updated the TOC. Page 46 (OLD) 48 (NEW): Deleted out-effected actuator p/n. Rewrote footnotes. Page 49 (OLD) 51 (NEW): Updated dwg. Rewrote footnote # 2. Page 51 (OLD) 53 (NEW): Updated HUM1 p/ns. Page 54 (OLD) 56 (NEW): Updated dwgs., table headers, & p/ns. Page 55 (OLD) 57 (NEW): Updated VFD dwg. Page 57 (OLD) 59 (NEW): Changed Aux Drain Pan p/n “055926503” to “057356802” & updated coding, rewrote footnotes. Page 59 (OLD) 61 (NEW): Updated Ref #2, 3 HW Coil p/ns. Added footnote #2 & footnote notation. Page 61- 63 (OLD) 63- 65 (NEW): Misc. p/n updates/corrections. Page 66, 67 (OLD) 68, 69 (NEW): Deleted pgs. Repaginated form & updated the TOC. Page 67- 72: Misc. p/n updates/corrections. Page 86- 88, 90: Rewrote table headers. Page 89: Rewrote table header & footnote # 1. Page 92: Changed “Lamp” to “Bulb” or “Fixture”. Page 96: Added Freezestat FS1 p/n “072502001”. Page 109, 110: Updated/added dwgs. & p/ns. Rewrote footnotes & footnote notation. Page 112, 113: Misc. updates. Page 119, 120, 122, 123: Updated Ref. #34 TB11 p/ns & qtys. Added footnote. Page 124- 126, 128, 130: Updated misc. pns. Page 131: Updated/corrected Ref. #295 VM1 p/ns. Rewrote footnotes. Page 132, 133: Misc. p/n & Bub. updates. Page 134: Updated Latching Assy. descriptions. Rewrote footnote # 2. Page 136: Corrected Section Mounted Controls coding in section header. Page 143: (NEW): Added pg. for additional Notes. Repaginated form & updated the TOC. Page 143- 147 (OLD) 144- 148 ( (NEW): Updated dwgs, headers, footnotes, & misc. p/ns. Page 153: Added footnote #3. Page 154, 155 (NEW): Added pgs. for Digital Cmprs. & Components. Repaginated form & updated the TOC. Page 159 (OLD) 162 (NEW): Rewrote dwg. headers. Page 161 OLD) 164 New: Added TD1, 2; DCC; TB35, 36 description & p/ns. rewrote footnotes, deleted CS1, 2 p/ns. Page 162 (OLD): Deleted pg. (T1 Trans. only used on RCS units when Code 12= *A.) Repaginated form & updated the TOC. Page 168 (OLD) 170 (NEW): Deleted TD1, 2 info. Moved to pg. 162. Page 170 (OLD) 172 (NEW): Added MTIII Remote Keypad & Remote Interface p/ns. Page 171, 174 (OLD) 173, 176 (NEW): Added SHS1 p/ns. Updated/corrected R63 p/ns. Page 173 (OLD) 175 (NEW): Corrected SPS1, 2 p/n from “910177462” to “ 910117462”. Added RHB1, 2 from (OLD) pg. 226. Added MTIII Remote Keypad & Remote Interface p/ns. Added Transducer Snubber p/n. Page 176, 199 (OLD): Deleted pg. Repaginated the form & updated the TOC. Page 195, 196 (OLD) 196, 197 (NEW): Updated/corrected Cond. Fan component p/ns. Page 200: Updated T1 trans. & components p/ns. Page 223 (NEW): Added pg. for IE. Repaginated form & updated the TOC. Page 224, 225 (OLD) 225, 226 (NEW): Added 061D components. Updated HGBP/Liquid Line p/ns & rewrote footnotes. Page 226 (OLD) 227 (NEW): Rewrote pg. header coding. Deleted Interface Board p/n.; moved p/n to Controls section. AO 08/17 Page 225, 226: Added Liquid Line Check Vlv. p/n. Page 227: Added additional Ref # 200 p/n, updated the Sensor p/n, corrected Check Vlv. p/ns & deleted footnote # 2. AP 09/17 Page 7: Misc. code updates. Page 143, 167: Rewrote Notes. Page 164: Added 1/17 & Later PVM components. Page 179: Corrected PVM qty. Page 189- 197: Rewrote pg. header. Page 201: Added 2/17 & Later PVM components. Added footnote # 3. AQ 02/18 Page 149: Updated CC Heater Ref # 145. Updated Cmpr. dwg. Page 150- 152. Updated Cmpr. dwg. Page 172, 175: Deleted OBS 193408001 Display. Combined with Remote Keypad 193408003.

Daikin Applied, 13600 Industrial Park Blvd., P.O. Box 1551, Minneapolis, MN 55440 (763) 553-5330

Page 6: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 6

NomenclatureUnit Model and Serial Number

R P S 050 D AUnit Model Number

Roofpak: R= Roofpak Applied Rooftop

Unit Configuration P= Heating, mechanical cooling D= Heating, mechanical cooling, DrawThru F= Heating, future mechanical cooling C= Condensing section only

Zone S, T= Singlezone Unit

Nominal Capacity (Tons) Ex. 050= 50 Tons

Design Vintage

Heating Medium A= Natural Gas E= Electric S= Steam W= Hot Water Y= None (cooling only)

FBO U 09 10 048120Plant Identification AbbreviationFBO= Faribault, MN

Serial Number (build sequence)

U= UnitYear of Manufacture09= 2009, 10= 2010, 11= 2011, 12= 2012, etc.

Month of Manufacture01= Jan.02= Feb.03= Mar.

04= Apr.05= May06= Jun.

07= July08= Aug.09= Sept.

10= Oct.11= Nov.12= Dec.

Serial Number

Page 7: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 7

NomenclatureUnit Code Index 1

General OptionsUnit Model Codes that Pertain: 19, 20, 21, 22, 23 (Mid 2012 & Earlier), 58 (Mid 2012 & Later)

Auxiliary Controls/Remote SensorsUnit Model Codes that Pertain: 12, 13, 16, 17, 18

Sections A1, A2Return/Outside Air/Heat Recovery OptionsUnit Model Codes that Pertain: 19, 20, 21, 22, 23 (Mid 2012 & Earlier); 24, 58 (Mid 2012 & Later)

Sections B, C, D, EDrawThru Cooling SectionsSection B- Filter SectionUnit Model Codes that Pertain: 25, 33 (Mid 2012 & Later), 50 (Mid 2012 & Later)

Section C- DrawThru Blank AccessUnit Model Codes that Pertain: 14, 15, 26

Section D- DrawThru Cooling Section Unit Model Codes that Pertain: 03, 27, 28

Section E- Spacer Section (RPS, RFS)Unit Model Codes that Pertain: 04, 30

Section E- DrawThru Heating Section (RDT)Unit Model Codes that Pertain: 30

Section F- Supply Fan OptionsUnit Model Codes that Pertain: 31, 32, 59 (Mid 2012 & Later), 08, 14, 15, 40, 49

Sections G, H, IBlowThru OptionsSection G= BlowThru Heat/BlankUnit Model Codes that Pertain: 04, 34

Section H= BlowThru Blank AccessUnit Model Codes that Pertain: 34

Section I- BlowThru Cooling SectionsUnit Model Codes that Pertain: 03, 35, 36

Section J- Final Filter SectionUnit Model Codes that Pertain: 39

Section K- Discharge Plenum SectionUnit Model Codes that Pertain: 40

Section L- Out-of-Airstream Blank Access SectionUnit Model Codes that Pertain: 41

Section M- Condenser SectionUnit Model Codes that Pertain: 09, 12, 43, 44, 47, 54, 68

Section N- Main Control PanelUnit Model Codes that Pertain: 04, 08, 09, 11, 12, 14, 15, 17, 18,23 (Mid 2012 & Later), 68

Section O- Refrigeration TubingUnit Model Codes that Pertain: 03, 45, 46, 48, 54 (Mid 2012 & Later), 68

RPS 050D S W Y 1 EY D 27 AL P1 LE 1 1 S 3 CD S120 BY AE 40B2 JEY Code 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22

1250C Y AB Y CYYS 4Z083D YYYYYY YYYYYY 30A2 LEY 1250A W11E3E 23 24 25 26 27 28 29 30 31 32 33 34

CYYS 4Z083D YYYYYY Y Y BY Y 4 MS R 1 1 1 Y D YY1AA 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50-54

1 An "X" located in ANY position in a code string (ESPECIALLY Code 50 for units built mid 2012 & earlier OR Code 60 for units built 2012 & Later) indicates the presence of special feature(s). It is important to note that special features may change unit components in unexpected areas so it is recommended to contact Daikin Applied with model and serial number information in order to correctly identify the required part(s). In mid 2012 the code structure was changed from a 54 code index to a longer more detailed format. A sample 54 Code version is shown above.

Page 8: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 8

Code 03= Cooling Coil S= Small L= Large Y= None

Code 04= Heat Type A= Natural Gas S= Steam B= Propane W= Hot Water E= Electric Y= None

Code 05= Unit Split F= Fan/Heat Y= None

Code 06= Insulation and Liners 1= 1”, 3/4# with liners on doors 2= 1½”, 1½# with solid liners on doors & ceilings 3= 1½”, 1½# with perforated liners in plenums, solid elsewhere 4= 1½”, 1½# with solid liners on doors, ceilings and floors 5= 1½”, 1½# with perforated liners in plenums, solid elsewhere (including floors) 6= 1½”, 1½# with SS Solid Liners on doors, ceilings and floors

Code 07= Approval Agency Listing CC, CD, CY= ETL Canada EM, EU, EY, YU= ETL/MEA- USA YY= None

Code 08= Main Control Box Location D= Discharge Plenum (RPS, RFS) OR Standard (RCS) F= Supply Fan Section (RDT)

Code 09= Unit Voltage 12= 208/60/3 29= 230/60/3 27= 460/60/3 37= 575/60/3

Code 10= Starting Option AL= Across- The- Line

Code 11= Field Power Connection and Disconnect P1= Single Power Block: Complete Unit Q1= Two Power Blocks: EH/Balance of Unit R1= Two Power Blocks: Fans & Controls/Balance of Unit A2= One, thru-the-door Disconnect: Complete Unit C2= Two, thru-the-door Disconnects: SAF&RAF&CB/Balance of Unit B2= Two, thru-the-door Disconnects: EHB/Balance of Unit D2= Three thru-the-door Disc.: EH/SAF&RAF&CB/Balance of Unit

Code 12= Temperature ControlsMicroTech III Digit 1: Communication Type L= LonWorks B= BACNet w/MSTP E= BACNet w/Ethernet S= Standalone (no communication) C= BACNet/MSTP (VAV Contactor configurable) A= Daikin D3 Gateway (VRV communication) Digit 2: Control Type E= Discharge Air w/ Static Pressure Control F= Space OR Zone Ctl. W= Discharge Air w/ Space ControlNo Controls YM= No Temperature Controls w/floating point control YC= No Temp. Ctls. w/6-9 volt DC modulating gas heat Actuator YA, 1A, 2A= RCS Standalone unit codes (see RPL form 7000136)

NomenclatureUnit Code Index, Continued

Code 18= Misc. Controls/ Unit Length A, S, Y___= None (___= Air Handler Length [in.]) K, R___= Remote Keypad (___= Air Handler Length [in.]) U___= Unit Powered Receptacle (___= Air Handler Length [in.]) V___= K + U (___= Air Handler Length [in.])

Code 19= Return Air Plenum YY= No section BY= Bottom Return BB= Bottom Return w/Burglar Bars BE= Bottom Return w/Isolation Damper HY= Back Return LY= Left Return SY= Side Return

Code 13= Air Flow Controls Y= None 1= 1 Duct Sensor 2= 2 Duct Sensors 3= 1 Duct and 1 Space Sensor 4= 1 Space Sensor Code 14= Inverters Y= None Separate Section 1= SA Fan only w/ Bypass 2= SA & RA Fans w/ Bypass 4= RA only w/ BypassNo Separate Section 3= SA Fan only w/ Bypass 5= SA & RA Fans w/ Bypass 6= SA Fan only no Bypass 7= SA & RA Fans no Bypass 8= RA Fan only w/ Bypass 9= RA Fan only no Bypass

Code 15= Inverter Brand Y= None A= ABB Inverter G= Graham Inverter Q= Schneider Inverter R= Reliance Inverter S, B= Daikin Applied Inverter F= Field Installed Inverter controlled by MicroTech

Code 16= Smoke Detectors Y= None 1= Return Air Fan Section 2= Supply Air Fan Section 3= (RAF) + (SAF)

Code 17= Misc. Aux. ControlsC G

Y= NoneF= Freezestat (Steam OR HW Heat only)P= Phase FailureG= Ground Fault ProtectionL= Line Reactors (Inverter w/ separate section only)A= Freezestat & Phase Failure (Steam OR HW Heat only)B= Freezestat & Ground Fault (Steam OR HW Heat only)C= Phase Failure & Ground FaultD= Freezestat, Phase Failure & Ground Fault (Steam OR HW Heat only)E= Freezestat & Line Reactors (ST/HW Heat & Inverter w/separate section only)H= Phase Failure & Line Reactors (Inverter w/ separate section only)J= Freezestat, P.F. & Line Reactors (ST/HW Heat & Inverter w/separate section only)K= Ground Fault, Phase Failure & Line Reactors (Inverter w/ separate section only)1= UV Lights2= UV Lights + F3= UV Lights + P4= UV Lights + L5= UV Lights + A6= UV Lights + E7= UV Lights + H8= UV Lights + J

C= Differential EnthalpyY= None (includes mechanical enthalpy)

Page 9: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 9

NomenclatureUnit Code Index, Continued

Code 20= Outdoor Air Options YY= None AE= 100% Outside air Damper w/ Hood & Actuator AY= 100% Outside air damper w/ Hood w/o Actuator BE= 0- 30% Outdoor air section w/ Actuator BY= 0- 30% Outdoor air section w/o Actuator DE= 0- 100% Econ. w/ barometric exhaust Damper w/ Act. DY= 0- 100% Econ. w/ barometric exhaust Damper w/o Act. EE= 0- 100% Econ. w/ power closure exhaust Damper w/ Act. EY= 0- 100% Econ. w/ power closure exhaust Damper w/o Act. HE= 0- 100% Econ. w/ prop exhaust Damper w/ Act. HY= 0- 100% Econ. w/ prop exhaust Damper w/o Act. FE= same as DE + Design Flow FY= same as DY + Design Flow GE= same as EE + Design Flow GY= same as EY + Design Flow JE= same as HE + Design Flow JY= same as HY + Design Flow KE= same as DE + Ebtron Sensor KY= same as DY + Ebtron Sensor LE= same as EE + Ebtron Sensor LY= same as EY + Ebtron Sensor ME= same as HE + Ebtron Sensor MY= same as HY + Ebtron Sensor 3E= Energy Recovery Economizer, Low CFM- 6” wheel 4E= Energy Recovery Economizer, Low CFM- 12” wheel 5E= Energy Recovery Economizer, High CFM- 6” wheel 6E= Energy Recovery Economizer, High CFM- 12” wheel

Code 21= Return Air Fan YYYY= No Return Air Fan 40B()= 40” Airfoil Single Width ()= Isolator type: 1= Rubber-in-Shear (RIS) 2= Spring 3= Spring w/ seismic restraints

Code 22= Return Air Fan Motor YYY= No Return Fan J E Y

Code 23= Return Air Fan Drive Selection (Mid 2012 & Earlier RPS, RFS, RDT ALL) YYYY= No Return Air Fan _ _ _ _ A

Y= NoneS= Shaft Ground Kit

E= High Eff. ODP motorH= High Eff. Totally-EnclosedJ= Premium Eff. ODPK= Premium Eff. Totally-Enclosed

G= 2.0 HPH= 3.0 HPJ= 5.0 HPK= 7.5 HP

L= 10.0 HP Q= 30.0 HPM= 15.0 HP N= 20.0 HP P= 25.0 HP(prop exhaust option is always J [5.0 HP])

Service Factor/Pitch TypeA= Std. SF/Fixed PitchB= 150% SF/Fixed PitchC= Std. SF/Variable PitchD= 150% SF/Variable Pitch

RequiredRPM

Code 23= Miscellaneous Electrical Options (Mid 2012 & Later RPS, RFS, RCS ALL)Digit 1: UV Lights Y= NoneDigit 2: Plenum/Vestibule Lights Y= NoneDigit 3: SpeedTrol, Energy Recovery, HGRH Inverter Y= None A= ABB B= Daikin Applied Q= SchneiderDigit 4: 115V Service Outlet Y= Field Supplied 115V Power, Outlet by Factory F= Factory supplied Line Voltage & OutletDigit 5: Intelligent Equipment (IE) Y= None A= Intelligent Equipment

Code 24= Exhaust Fans OR Frost Protection Y= None 1= 1 Prop Exhaust Fan w/ Hood 2= 2 Prop Exhaust Fans w/ Hood F= Heat Recovery Frost Protection Inverter

Code 25= DrawThru Filter SectionDigit 1: Section Type Y= No section A= 2” Angular (24” Section) D= Angular with low CFM Blender- 48/24” section E= Angular with high CFM Blender- 48/24” section F= Flat (24” Section) G= Flat with low CFM Blender- 48/24” section (RPS, RFS Mid 2012 & Earlier, RDT ALL) G= 4” Angular- 24” section (RPS, RFS Mid 2012 & Later) H= Flat with high CFM Blender- 48/24” section L= Large Staggered- 48/24” section S= Staggered- 48” section T= Staggered with low CFM Blender- 48/48” section V= Staggered with high CFM Blender- 48/48” section B, D= Blank 24” section C, E= Blank 48” sectionDigit 2: Filter Type Y= No Filter media supplied B= Throwaway 30% Efficient C= Throwaway 30% Efficient w/Intersept H= Cartridge 85% Efficient w/ Intersept (RPS, RFS Mid 2012 & Earlier, RDT ALL) H= Throwaway 85% Efficient (RPS, RFS Mid 2012 & Later) D= Cartridge 65% Efficient E= Cartridge 95% Efficient G= Cartridge 95% Efficient w/Intersept

Code 26= Blank DrawThru Section Y= No section E= Blank 24” Section F, S= Blank 48” Section

Code 27= DrawThru Drain Pan/Cooling Coil SectionDigits 1- 3: Cooling Type CYY= Cooling unit DYY= Drain Pan only (48” section) GYY= Cooling w/ Hot Gas Reheat Digit 4: Options S= Std. stainless steel Drain Pan P, Y= Std. painted galvanized steel Drain Pan L= Wide stainless steel Drain Pan (Digits 1- 3= DYY only) T= Wide painted galvanized steel Drain Pan (Digits 1- 3= DYY only)

Page 10: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 10

NomenclatureUnit Code Index, Continued

Code 29= DrawThru Heating CoilYYYYYY= No Heating Coil

Code 30= DrawThru Heating Section (RDT only)OR Blank Spacer Section (RPS only)YYYYYY= No Heating SectionEEEEEE= Blank 24” SectionBBBBBB, FFFFFF= Blank 48” Section

W22 J 3 E

2= 2 Way Steam Valve Y= No Valve3= 3 Way HW Valve

E= 1¼” Valve Pkg. H= 2½” Valve Pkg.F= 1½” Valve Pkg. J= 3.0” Valve Pkg.G= 2.0” Valve Pkg. Y= No Valve Pkg.

S11= 5JA0601H (6FPI, 1 Row 5J Steam Coil)S12= 5JA1201H (12FPI, 1 Row 5J Steam Coil)S13= 5JA0602C (6FPI, 2 Row 5J Steam Coil)S14= 5JA1202C (12FPI, 2 Row 5J Steam Coil)W11= 5WH0901H (9FPI, 1 Row 5WH HW Coil)W22= 5WS0902C (9FPI, 2 Row 5WS HW Coil)

E= Electric ActuatorY= Less Actuator

Always ‘Y’

1= 1 Stage 2= 2 Stages 4= 4 Stages 6= 6 Stages

E020= 20 KW Heater E200= 200 KW HeaterE040= 40 KW Heater E240= 240 KW HeaterE060= 60 KW HeaterE080= 80 KW HeaterE100= 100 KW HeaterE120= 120 KW HeaterE160= 160 KW Heater

E020 1 Y

Code 31= Supply Air Fan 27A()= 27” Airfoil Double Width 27F()= 27” Forward Curved, LP 27M()= 27”Forward Curved, MP 30A()= 30” Airfoil Double Width 30M()= 30”Forward Curved, MP 33A()= 33” Airfoil Double Width 33F()= 33” Forward Curved, LP 33M()= 33”Forward Curved, MP 40B()= 40” Airfoil Single Width (RDT only) 44B()= 44” Airfoil Single Width (RDT only) ()= Fan Isolators 1= Rubber-in-Shear (RIS) 2= Spring 3= Spring w/Seismic Snubbers

E= High Eff. ODP motor H= High Eff. Totally-EnclosedJ= Premium Eff. ODP MotorK= Premium Eff. Totally-Enclosed

H= 3.0 HP M= 15.0 HP R= 40.0 HPJ= 5.0 HP N= 20.0 HP S= 50.0 HPK= 7.5 HP P= 25.0 HP L= 10.0 HP Q= 30.0 HP

Code 32= Supply Air Fan MotorK E Y

Code 33= Supply Air Fan Drive Selection (Mid 2012 & Earlier RPS, RFS, RCS, RDT ALL) YYYY= None (RCS) _ _ _ _ A

RequiredRPM

Service Factor/Pitch TypeA= Std. SF/Fixed PitchB= 150% SF/Fixed PitchC= Std. SF/Variable PitchD= 150% SF/Variable Pitch

Code 34= BlowThru Heat Section (RPS, RFS only)YYYYYY= No section, cooling onlyBBBBBB= Blank 48” section, no heat, cooling only

E= Modulating BurnerR= Modulating Burner/with H.P. Regulator Range= 2-3 psiS= Modulating Burner/with H.P. Regulator Range= 5-10 psiH= Hi Turn Down Burner 20:1T= Hi Turn Down Burner 20:1/with H.P. Regulator Range= 2-3 psiU= Hi Turn Down Burner 20:1/with H.P. Regulator Range= 5-10 psi

S= Stainless Steel Heat Exchanger

MBH (in 10’s)ex. 020= 200 MBH [020,025,032,040,050,064,065,079,080,100]

Gas Heat Breakdown:020 S S C

A= Low CFM Baffle Position B= Medium CFM Baffle Position C= High CFM Baffle Position

2= 2 Way Steam Valve Y= No Valve3= 3 Way HW Valve

E= 1¼” Valve Pkg. H= 2½” Valve Pkg.F= 1½” Valve Pkg. J= 3.0” Valve Pkg.G= 2.0” Valve Pkg. Y= No Valve Pkg.

S11= 5JA0601H (6FPI, 1 Row 5J Steam Coil)S12= 5JA1201H (12FPI, 1 Row 5J Steam Coil)S13= 5JA0602C (6FPI, 2 Row 5J Steam Coil)S14= 5JA1202C (12FPI, 2 Row 5J Steam Coil)W11= 5WH0901H (9FPI, 1 Row 5WH HW Coil)W22= 5WS0902C (9FPI, 2 Row 5WS HW Coil)

E= Electric ActuatorY= Less Actuator

Hydronic Heat Breakdown:W22 J 3 E

3= 3 Row 5= 5 Row4= 4 Row 6= 6 Row

08= 8 Fins-per-inch10= 10 Fins-per-inch12= 12 Fins-per-inch14= 14 Fins-per-inch

4Z= Type 4EZ

D= Lanced AluminumC= Hi-F Copper w/ SS casingJ= Hi-F Aluminum

Code 28= DrawThru Cooling Coil YYYYYY= No Cooling Coil4Z 08 3 D

Code 33= Miscellaneous Mechanical Options (Mid 2012 & Later)Digit 1: Gauges Y= None A= Magnehelic/Differential Filter Gauge in DrawThru section B= Magnehelic/Differential Filter Gauge in BlowThru section C= Magnehelic/Differential Filter Gauge in DT & BT sectionsDigit 2: California Title 24 Y= None F= Economizer w/ Fault Detection/Diagnosis (FDD) Digit 3: Ebtron Air Flow Y= None S= Ebtron Air Flow (Hybrid) G= Ebtron Air Flow (Gold)Digit 4: Heating Coil Options Y= None E= Electrofin CoatingDigit 5: Cooling Coil Options Y= None E= Electrofin Coating

Y= NoneS= Shaft Ground Kit

Page 11: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 11

NomenclatureUnit Code Index, Continued

Code 37= N/A to RPS/RDT/RFS/RCS- Always YYYYYY

Code 38= BlowThru Blank Access Section (Mid 2012 & Earlier) Y= No section B= Blank Section after Heat Section- 48” section

Code 38= Attenuator Section (Mid 2012 & Later) Y= No section G= With 36” Std. Straight Attenuator K= With 36” Std. Straight Attenuator w/ Tedlar Coating H= With 60” Std. Straight Attenuator L= With 60” Std. Straight Attenuator w/ Tedlar Coating J= Std. Elbow Attenuator M= Std. Elbow Attenuator w/ Tedlar Coating F= Blank 48” Section E= Blank 24” Section

Code 39= Final Filter Section Y= No section A= Flat filter section, 95% cartridge, 24/24” section J= Flat filter section, 95% cartridge, 24” section B= Staggered filter section, 95% cartridge, 24/48” section K= Staggered filter section, 95% cartridge, 48” section E= Flat filter section, 95% cartridge w/ Intersept, 24/24” section L= Flat filter section, 95% cartridge w/ Intersept, 24” section F= Staggered filter section, 95% cartridge w/ Intersept, 24/48” section M= Staggered filter section, 95% cartridge w/ Intersept, 48” section G= Flat filter section, 95% HEPA cartridge, 24/48” section N= Flat filter section, 95% HEPA cartridge, 48” section H= Flat filter section, 95% cartridge, 48/48” section C, Q= Blank- 24/24” section D, R= Blank- 24/48” section S= Blank- 24” section T= Blank- 48” section

Code 40= Discharge Plenum BY= Bottom Discharge BB= Bottom Discharge w/ Burglar Bars BE= Bottom Discharge w/ Discharge Damper FY= Front Discharge (RFS) LY= Left Side Opposite Side RY= Right Side Drive Side SY= LH Side Discharge HY= LH Side Discharge (RDT) GY= Bottom Discharge (RDT) GB= Bottom Discharge w/ Burglar Bars (RDT)

Code 41= Out-of-Airstream Blank Access Section Y= None 1= 48/24” Blank Section only- out of airstream with light 2= 48” Blank Section only- out of airstream with light

Code 42= Compressor Capacity Control 4= 4 steps (045- 068) 6= 6 steps (070- 079)

Code 43= Condenser Options YY= None (RFS)Digit 1: Air Coil M= 25mm Micro Channel Coil P= 25mm Electrofin Coated Micro Channel Coil T= 32mm Micro Channel Coil U= 22mm Electrofin Coated Micro Channel Coil Y= NoneDigit 2: Condenser Options G= Coil Guards, Steel S= Seal Tite Conduits B= G + S Y= None

Code 44= Compressor TypeR= Standard Scroll, R410A 1

D= Digital Scroll, R410A 1

Code 45= Compressor Isolation 1= Resilient Rubber-in-Shear Y= None (RFS) Code 46= Piping Options 1= Hot Gas Bypass, circuit #1 only 2= Hot Gas Bypass, cir. # 1 & 2 3= Replaceable Filter Drier Core 4= 1 + 3 5= 2 + 3 Y= None Code 47= Low Ambient Operation 1= FanTrol Standard Fans 2= SpeedTrol Standard Fans 3= Quiet Fan + FanTrol 4= Quiet Fan + SpeedTrol Code 48= IBC Seismic Construction / Hot Gas Reheat Y= None A= ASCE 7- 10 Wind Certification H= Modulating Hot Gas Reheat I= Seismic Construction K= Modulating Hot Gas Reheat and Seismic Construction J= IBC Seismic Construction- Category E/F

Code 49= Fan Section Options A= SA Fan Belt Guard E= SA & RA Fan Section Light B= SA Fan Section Light F= D + E C= A + B Y= None D= SA & RA Fan Belt Guard

Code 50= Miscellaneous (Mid 2012 & Earlier) YY= None XX= Special

Code 34= BlowThru Heat Section, Continued

Always ‘Y’

1= 1 Stage 2= 2 Stages 4= 4 Stages 6= 6 Stages

E020= 20 KW Heater E120= 120 KW HeaterE040= 40 KW Heater E160= 160 KW HeaterE060= 60 KW Heater E200= 200 KW HeaterE080= 80 KW Heater E240= 240 KW Heater E100= 100 KW Heater

Electric Heat Breakdown:E020 1 Y

Code 35= BlowThru Coil Section/Drain Pan (RPS, RFS only) YYYY= No sectionDigits 1- 3: Cooling Type CYY= Cooling unit DYY= Drain Pan only- 48” section GYY= Cooling w/ Hot Gas ReheatDigit 4: Options S= Std. stainless steel Drain Pan P, Y= Std. painted galvanized steel Drain Pan L= Wide stainless steel Drain Pan (Digits 1- 3= DYY) T= Wide painted galvanized steel Drain Pan (Digits 1- 3= DYY)

3= 3 Row 5= 5 Row4= 4 Row 6= 6 Row

08= 8 Fins-per-inch 12= 12 Fins-per-inch10= 10 Fins-per-inch 14= 14 Fins-per-inch

4Z= Type 4EZ

D= Lanced AluminumC= Copper Fin

Code 36= BlowThru Cooling Coil (RPS, RFS only)YYYYYY= No Cooling Coil4Z 08 3 D

1 Note that there are some Digital Scroll Compressor units built as SPECIALS (Code 44= R AND Code 60= XX with Digital Scroll compressors listed as a special feature). Refer to the Condenser Section Notes for more information on Digital Scroll Compressor units.

Page 12: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 12

Code 55= Ultra High Efficiency Units YY= None HE= Ultra High Efficiency Unit (051D, 063D, 079D)

Code 56= Chicago Code/Refrigeration Service Valves YY= None CC= Chicago Code YV= Refrigeration Service Valves CV= Chicago Code w/ Refrigeration Service Valves Code 57= N/A to RPS/RDT/RFS/RCS- Always YY

Code 58= Return Air Fan Drive Selection_ _ _ _ A

Service Factor/Pitch TypeA= Std. SF/Fixed PitchB= 150% SF/Fixed PitchC= Std. SF/Variable PitchD= 150% SF/Variable Pitch

Code 59= Supply Air Fan Drive Selection_ _ _ _ A

Service Factor/Pitch TypeA= Std. SF/Fixed PitchB= 150% SF/Fixed PitchC= Std. SF/Variable PitchD= 150% SF/Variable Pitch

Code 60= Misc. Specials YY= None XX= Special

Code 61= Packaging/ASHRAE Certification 1= Steel Skid 2= Consolidated Ship 3= Steel Skid w/ ASHRAE Certification 4= Consolidated Ship w/ ASHRAE Certification

Code 62= Parts Warranty A= Standard One Year Parts C= Extended One Year Parts, Two Year Total D= Extended Two Year Parts, Three Year Total E= Extended Three Year Parts, Four Year Total F= Extended Four Year Parts, Five Year Total Z= Special

Code 63= Compressor Warranty Y= None (RFS units only) A= Standard One Year Parts Q= Extended Four Year Compressor, Five Year Total Z= Special

Code 64= Heat Exchanger Warranty Y= None (Code 04 CANNOT= A) A= Standard One Year Heat Exchanger R= Extended Nine Year Heat Exchanger, Ten Year Total Z= Special

Code 65= Unit Family 047C= 045D- 075D 077C= 079D

Code 66= Drain Connection Y= None L= Left Side R= Right Side (drive side)

Code 67= ASHRAE Certification Y= None B= AHRI Certified-90.1 2010 C= AHRI Certified-90.1 2013

Code 68= Short Circuit Current Rating YY= None 10= 10 SCCR 22= 22 SCCR 65= 65 SCCR

Code 69- 72 N/A to RPS/RDT/RFS/RCS- Always YYYYYYYY

Code 50= Blender Section (Mid 2012 & Later) Y= None L= Low CFM Blender, 48” Section H= High CFM Blender, 48” Section E= Blank 24” Section F= Blank 48” Section

Code 51= Packaging (Mid 2012 & Earlier) 1= Steel Skid 2= Consolidated Ship

Code 51= Draw=Thru Pre-Heat Section (Mid 2012 & Later) YYYYY= None EEEEEE= Blank 24” Section FFFFFF= Blank 48” Section W 11 E 3 E

Y= No ActuatorE= Electric Actuator

Y= No Valve2= 2- Way Valve (ST)3= 3- Way Valve (HW)

Y= No ValveE= 1.25” Valve J= 3.00” ValveF= 1.50” ValveG= 2.00” ValveH= 2.50” Valve

11= 9 FPI 1 Row (HW) OR 6 FPI 1 Row (ST)12= 12 FPI 1 Row (ST)13= 06 FPI 2 Row (ST)14= 12 FPI 2 Row (ST)22= 9 FPI 2 Row (HW)

W= Hot Water Heat (HW)S= Steam Heat (ST)

Code 52= Parts Warranty (Mid 2012 & Earlier) A= Standard One Year Parts C= Extended One Year Parts, Two Year Total D= Extended Two Year Parts, Three Year Total E= Extended Three Year Parts, Four Year Total F= Extended Four Year Parts, Five Year Total Z= Special

Code 52= Drain Pan/Humidifier Section (Mid 2012 & Later) YY= None DH= Humidifier w/ stainless steel Drain Pan 48” section DY= Stainless steel Drain Pan only, 48” section EE= Blank 24” Section FF= Blank 48” Section

Code 53= Compressor Warranty (Mid 2012 & Earlier) Y= None (RFS) A= Standard One Year Parts Q= Extended Four Year Compressor, Five Year Total Z= Special

Code 53= Custom Specifications (Mid 2012 & Later) YY= None RR= “B” vintage replacement unit Code 54= Heat Exchanger Warranty (Mid 2012 & Earlier) Y= None (Code 04 CANNOT= A) A= Standard One Year Heat Exchanger R= Extended Nine Year Heat Exchanger, Ten Year Total Z= Special

Code 54= Hot Gas/Liquid Subcool Reheat (Mid 2012 & Later) YY= None BM= BlowThru Modulating Hot Gas Cir. #2 (includes SpeedTrol) ML= Modulating Liquid Subcool Reheat Circuits #1 & 2 BL= BlowThru Modulating, Hot Gas Circuit #2, AND Modulating Liquid Subcool Reheat Circuits #1 & 2

NomenclatureUnit Code Index, Continued

RequiredRPM

RequiredRPM

Page 13: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 13

NomenclatureUnit Section Layout Examples 1

A B C F G H J K MDRPS

A= Return Air/Outside Air/

Heat Recovery/Prop Exhaust Section

A B C F G H J K MD

A B C F G H J K MD A B C F G H J K MI

RDTA B C FE MD A B C FE MD

A B C F G H J KDRFS RCS

M

Prop Exhaust DrawThru Return Air Fan DrawThru

Heat Recovery DrawThru Heat Recovery BlowThru

Return Air Fan DrawThru

With Prop Exhaust With Return Air Fan

B, C, D, E=DrawThru Section

F=Supply Fan

Section

G, H, I=BlowThru Section

J=FinalFilter

K=Discharge Plenum

L=Out-of Air- Stream

Blank Access

M=Condenser Section

1 The Unit Section Layout Diagrams shown above are to be used for reference only. Unit sections and component locations may vary depending on unit size, configuration, and options selected.

Page 14: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 14

NomenclatureControl Locations 1

RDT

Electric Heat Control

Panel NMain Control

PanelCondenser Control Panel

(RCS Only)

Inverters, Line Reactors & Manual Bypass

Prop Exhaust(not shown)

Supply Air Section

Condenser Section

Condenser Control Panel(RCS Only)FanTrol/

SpeedTrol Box

Controls Locations

1 The Unit Section Layout Diagrams shown above are to be used only for reference. Sections and component locations may vary depending on unit size, configuration, and options selected.

RPS, RFS, RCS

Page 15: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 15

Schematic Sym. Description Location ACT3, 4 Actuator Motors, Economizer Economizer Section ACT5 Actuator Motor, Discharge Isolation Damper Discharge Section ACT6 Actuator Motor, Return Air Isolation Damper Return Air Section ACT7 Actuator Motor, Heat Face/Bypass Coil Section, Heat ACT8 Actuator Motor, Cool Face/Bypass Coil Section, Cool ACT10, 11 Actuator Motors, Exhaust Dampers Return Air Section ACT12, 13 Actuator Motors, Enthalpy Wheel Bypass Damper Energy Recovery Section AS Airflow Switch, Burner Blower Gas Heat Box BM Burner Blower Motor Furnace Section C1- C4 Power Factor Capacitors, Compressors Condenser Section C10 Power Factor Capacitor, Supply Fan Supply Air Section C20 Power Factor Capacitor, Return Fan Return Air Section CB10 Circuit Breaker, Supply Fan Main Control Box CB20 Circuit Breaker, Return/Exhaust Fan Main Control Box CB60 Circuit Breaker, Energy Recovery Wheel Main Control Box CDT Thermister, Discharge Digital Compressor Condenser Section COMPR.1- 4 Compressors Condenser Section DAT Discharge Air Temperature Sensor Discharge section DCC Digital Compressor Controller Main Control Box DFLH Design Flow Sensor, Left Hand Return Section DFRH Design Flow Sensor, Right Hand Return Section DHL Duct High Limit Main Control Box DS1 Disconnect, Total Unit OR Condenser/Heat Main Control Box DS2 Disconnect, SAF/RAF/Controls Main Control Box DS3 Disconnect, Electric Heat Electric Heat Section DS4 Disconnect, Condenser (RCS only) RCS Control Box DS6 Disconnect, Factory Powered Outlet Condenser Section EAT Exhaust Air Temperature Sensor Energy Recovery Section EFT Entering Fan Air Temperature Sensor Supply Fan Section ERM1, 2 Energy Recovery Wheel Motors Energy Recovery Section EXPA, B, C Expansion Boards Main Control Box F1A, B Fuses, Control Circuit Transformer, (T1) Primary Main Control Box F1C Fuse, Control Circuit Transformer, (T1) Secondary Main Control Box F2 Fuse, Control Circuit Transformer, (T2) Primary Main Control Box F3 Fuse, Burner Blower Motor Main Control Box F6A, B Fuses, Transformer, (T6) Primary Condenser Section F6C Fuse, Transformer, (T6) Secondary Condenser Section F12A, B Fuses, Digital Compressor Transformers Main Control Box FB10 Fuseblock, Supply Air Fan Main/Cond. Control Box FB11, 12, 21, 22 Fuseblocks, SpeedTrol Main/Cond. Control Box FB20 Fuseblock, Return Air Fan Main/Cond. Control Box FB31- 40 Fuseblocks, Electric Heat (Top Bank) Electric Heat Box FB41- 50 Fuseblocks, Electric Heat (Bottom Bank) Electric Heat Box FB60 Fuseblock, Energy Recovery Wheel Main/Cond. Control Box FD Flame Detector Furnace Section FLC Fan Limit Control Furnace Section FP1, 2 Frost Protection, Refrigeration Circuits Coil Section, Cool FS1, 2 Freezestat Controls Coil Section, Heat/Cool FSG Flame Safeguard Gas Heat Box GFR1, 2 Ground Fault Relays Main Control Box GFS1, 2 Ground Fault Sensors Main Control Box GFR4 Ground Fault Relay, Condenser Condenser Control Box GFS4 Ground Fault Sensor, Condenser Condenser Control Box

Electrical Legend

Page 16: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 16

Electrical LegendContinued

GRD Ground All Control Boxes GV1 Gas Valve, Pilot Furnace Section GV2 Gas Valve, Main/Safety Furnace Section GV3 Gas Valve, Redundant/Safety Furnace Section GV4- 8 Gas Valves, Main, Hi-Turn Down Furnace Section HL1- 10 High Limits, Power, Electric Heaters (Top Bank) Electric Heat Section HL11- 20 High Limits, Power, Electric Heaters (Bottom Bank) Electric Heat Section HL22 High Limit, Gas Heat (Prefilters) Supply Air Section HL23 High Limit, Gas Heat (Final Filters) Final Filter Section HL31- 40 High Limits, Control, Electric Heaters (Top Bank) Electric Heat Section HL41- 50 High Limits, Control, Electric Heaters (Bottom Bank) Electric Heat Section HP1- 6 High Pressure Controls, Refrigerant Compr./Press./Cond. Box HP5 High Pressure Control, Gas Furnace Section HS1 Heat Switch, Electric Shutdown Main Control Box HS3 Heat Switch, Electric Heat Deadfront Interlock Electric Heat Box HTR1- 6 Crankcase Heaters On Compressors HUM1 Humidistat Sensor Energy Recovery Section IT Ignition Transformer Furnace Section LAT Temperature Sensor, Leaving Air Energy Recovery Section LP1- 6 Low Pressure Controls, Refrigerant On Compr./Cond. Box LP5 Low Pressure Control, Gas Furnace Section LR10 Line Reactor, Supply Fan Inverter Bypass Box LR20 Line Reactor, Return/Exhaust Fan Inverter Bypass Box LR11, 21 Line Reactors, Condenser Fan SpeedTrol Pressure/Cond. Box LS1, 2 Limit Switches, Low/High Fire Furnace Section LT10 Light, Supply Fan Supply Air Section LT11 Light, Return Fan Return Air Section LT12 Light, Heat Section Heat Section LT13 Light, Filter Section Filter Section LT14 Light, Final Filter Section Final Filter Section LT15 Light, Discharge Section Discharge Section LT16 Light, Blow-through Coil Section BlowThru Coil Section LT17 Light, Evaporator Coil Section Evaporator Coil Section LT18 Light, Preheat Section Preheat Section LT19 Light, Blank Section Blank Section LT20 Light, Blank/Empty Section Blank/Empty Section LT21 Light, DrawThru Coil Section DrawThru Coil Section LT22 Light, Condenser Section Condenser Section M1- 6 Contactors, Compressors Main/Cond. Control Box M10 Contactor, Supply Fan Main Control Box M11- 18 Contactors, Condenser Fans, Circuit #1 Main/Cond. Control Box M20 Contactor, Return Fan Main Control Box M21- 28 Contactors, Condenser Fans, Circuit #2 Main/Cond. Control Box M29 Contactor, Burner Motor Furnace Section M30 Contactor Reversing, Inverter Bypass, Supply Fan Inverter Bypass Box M31- 39 Contactors, Elec. Heaters (Top Bank) Electric Heat Section M40 Contactor, Reversing, Inverter Bypass, Return Fan Inverter Bypass Box M41- 50 Contactors, Elec. Heaters (Bottom Bank) Electric Heat Section M60, 61 Contactors, Energy Recovery Wheel Motor Main Control Box MCB Microtech III Control Board Main Control Box MJ Mechanical Jumpers All Control Boxes

Schematic Sym. Description Location

Page 17: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 17

Electrical LegendContinued

Schematic Sym. Description Location MMP1- 6 Manual Motor Protectors, Compressors Main/Cond. Control Box MMP10 Manual Motor Protector, Supply Fan Main Control Box MMP11- 18 Manual Motor Protectors, Condenser Fans Ckt. 1 Main/Cond. Control Box MMP20 Manual Motor Protector, Return fan Main Control Box MMP21- 28 Manual Motor Protectors, Condenser Fans Ckt. 2 Main/Cond. Control Box MMP30 Manual Motor Protector, Inverter Bypass Supply Fan Inverter Bypass Box MMP40 Manual Motor Protector, Inverter Bypass Return Fan Inverter Bypass Box MMP51- 53 Manual Motor Protectors, Exhaust Fan(s) Prop Exhaust Box MMP60, 61 Manual Motor Protectors, Energy Recovery Wheel Main Control Box MP1- 6 Motor Protectors, Compressors On Compressors OAE Enthalpy Control, Outside Air Economizer Section OAT Temperature Sensor, Outside Air Economizer Section OL61 Overload- Energy Recovery Wheel (575V) Main/Cond. Control Box PB1, 2 Power Blocks, Power Distribution Main Control Box PB3 Power Block, Power Distribution, Electric Heat Electric Heat Section PB4 Power Block, Power Distribution, Condenser Cond. Control Box PB9, 10 Power Blocks, Supply Fan Junction Box, Split Unit PB11, 12 Power Blocks, Power Distribution Main Control Box PB19, 20 Power Blocks, Return/Exhaust Fan Junction Box, Split Unit PC5 Pressure Control, Clogged Filter Pre Filter Section PC6 Pressure Control, Clogged Final Filter Final Filter Section PC7 Pressure Control, Proof of Airflow Supply Air Section PC13, 23 Pressure Controls, FanTrol Pressure/Cond. Box PC29 Pressure Control, Coil Splitter Pressure/Cond. Box PT11, 21 Pressure Transducers, SpeedTrol Pressure/Cond. Box PVM1, 2 Phase Voltage Monitors Main Control Box PVM4 Phase Voltage Monitor, Condenser Condenser Control Box R1- 2 Relays, High Pressure Reset (RCS only) RCS Control Box R5- 8 Relays, Safety (RCS only) RCS Control Box R31- 36 Relays, Compressor Staging (RCS only) RCS Control Box R11 Relay, Cond. Fan 11 SpeedTrol Inverter Enable Pressure/Cond. Box R12- 14 Relays, FanTrol Condenser Fan Cycling Main/Cond. Control Box R17 Relay, Cond. Fan 21 SpeedTrol Inverter Enable Pressure/Cond. Ctrl. Box R20 Relay, Gas/Steam/Hot Water Furn./Main Ctrl. Box R21, 22 Relays, Gas Heat, 20:1 High Turndown Furn./Main Ctrl. Box R23 Relay, Gas Heat Furnace Section R24 Relay, Gas Heat Alarm Main Control Box R25 Relay, Gas Heat, Start Supply Fan Inverter Main Control Box R26 Relay, Isolation/Exhaust Dampers Main Control Box R28 Relay, Isolation Damper Safety Main Control Box R45 Relay, UV Lights Main Control Box R70- 90 Relays, Specials/Digital Compressor Main Control Box RAE Enthalpy Sensor, Return Air Return Air Section RAT Temperature Sensor, Return Air Return Air Section REC1 Receptacle, Main Box Main Control Box REC2 Receptacle, Condenser Box Cond. Control Box REC3 Receptacle, Field Power, 115VAC Discharge Bulkhead REC10- 23 Receptacles, Cabinet Sections Cabinet Sections S1 Switch, System On/Off Main Control Box S2 Switch, System On/Off, RCS Unit Cond. Control Box S3 Switch, Furnace On/Off Furnace Section

Page 18: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 18

Electrical LegendContinued

S4 Switch, Inverter Bypass On/Off Main Control Box S40- 45 Switches, Door Interlock, UV Lights Cabinet Sections SC11 Speed Control, Circuit #1 Cond. Bulkhead SC21 Speed Control, Circuit #2 Cond. Bulkhead SD1 Smoke Detector, Supply Air Discharge Section SD2 Smoke Detector, Return Air Return Air Section SHS1 Sensor, Space Humidity Return Section (Field inst.) SPS1, 2 Sensors, Static Pressure, Duct or Building Main Control Box SV1, 2 Solenoid Valves, Liquid/Drop Condenser Section SV7 Solenoid Valve, Digital Compressor Condenser Section T1 Transformer, Main Control, Line/115VAC Main Control Box T2 Transformer, Control Input, 115/24VAC Main Control Box T3 Transformer, Control Output, 115/24VAC Main Control Box T6 Transformer, Factory Powered outlet, Line/115VAC Condenser Section T11 Transformer, SpeedTrol, Line/240VAC Condenser Section T12, 13 Transformers, Digital Compressors Main Control Box TB1 Terminal Block, Internal for Transformers Main Control Box TB2 Terminal Block, Field Main Control Box TB3 Terminal Block, Factory, 115/24VAC Main Control Box TB4 Terminal Block, Field, 115VAC Main Control Box TB5 Terminal Block, RCS Field, 115V Condenser Control Box TB6 Terminal Block, RCS Field Condenser Control Box TB7 Terminal Block, 115VAC Convenience Outlet Main Control Box TB8 Terminal Block, RCS, 115VAC Convenience Outlet Condenser Control Box TB11 Terminal Block, Heating Furn./Elect. Heat Ctrl. Box TB25- 28 Terminal Blocks, Split Unit Junction Box Split Unit Junction Box TB35, 36 Terminal Blocks, Digital Compressor Main Control Box TC12- 14 Temperature Controls, FanTrol Condenser Section TD1, 2 Time Delays, Compressor Lockout (RCS only) Condenser Control Box TD20 Time Delay, Return Air Fan Main Control Box TD29 Time Delay, Coil Splitter Main Control Box TR1, 2 Transducers, Pressure, SpeedTrol Main Control Box UV Ultra-Violet Light(s) Coil/Discharge Section VFD10 Adjustable Frequency Drive, Supply Fan DrawThru/Supply Section VFD11, 21 Adjustable Frequency Drives, Cond. Fan SpeedTrol Pressure/Cond. Ctrl. Box VFD20 Adjustable Frequency Drive, Return/Exhaust Fan Dr. Thru/Ret./Exh. Section VFD60 Adjustable Frequency Drive, Energy Recovery Wheel Energy Recovery Section VM1 Valve Motor #1, Heating Furnace/Heating Section VM5 Valve Motor #5, Cooling Coil Section, Cooling VV1 Vent Valve, Gas Heat Furnace Section ZNT1 Sensor, Zone Temperature, Setback Field Installed

Schematic Sym. Description Location

Page 19: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 19

Section A1- Outdoor/Return Air SectionNotes

Primary Codes that pertain: 19, 20, 21, 22, 23 (Mid 2012 & Earlier), 58 (Mid 2012 & Later)Additional Codes that pertain: 06, 09, 12, 14, 15, 16, 17, 23 (Mid 2012 & Later), 24, 33, 48, 49

Codes 19 and 20 determine the base section. Code 19 is the Return Air Plenum, and determines if the unit has back/horizontal return air, bottom return air, left side return air, OR side return air. A Return Air Plenum is required for any outdoor air application with an Economizer (Code 20= B*, D*, E*, F*, G*, H*, J*) OR Mixing Box (Code 20= C*). The only case in which a Plenum is not required is when a 100% Outdoor Air Damper and Hood are ordered (Code 20= A*). For units with Heat/Energy Recovery (Code 20= 3*, 4*, 5*, 6*) see Section A2.

Codes 21, 22, 23 (Mid 2012 & Earlier) AND/OR 58 (Mid 2012 & Later) determine the Return Air Fan, Motor and drive. These codes only pertain to units with a 0-100% Economizer (Code 20= D*, E*, F*, G* H*, J*). The Return Air Fan section parts, the fans, and the motors are listed in this section. Drive components (Fan Sheave, Motor Sheave, V-belt[s], and Sheave Bushing[s]- if required) are NOT listed as they are unique to the unit. If a drive component is required you may use the number from the part and cross reference it in the Daikin Applied Parts catalog, The Daikin Parts E-Commerce site, or contact Daikin Applied with model and serial number information. Return Fan motors range from 2- 30 horsepower, and the Fan is a 40” single width Airfoil Wheel.

Code 06, insulation and liners, influences the final cabinet assembly panel part numbers. For sheet metal components that make up the Outdoor/Return Air Section, contact Daikin Applied with model and serial number information to ensure that the correct liners, insulation and hardware are ordered. For standard Access Door Latching Assemblies, see Section H.

Code 09, unit voltage, is part of the Return Fan Motor part number identification.

Code 12, the control system, comes into play when an Economizer is present. The Economizer is supplied with an Actuator on MicroTech equipped units, but MAY OR MAY NOT come with a factory supplied Actuator if the unit has controls by others (Code 12= YM, YC).

Codes 14 & 15 determine if the unit has a Return Air Fan Inverter/AFD/VFD and if so where it is installed. If Code 14= 5, 7, 8, 9, the inverter is installed in the Supply Air Section. If Code 14= 2, 4 there is a separate Inverter Section. If Code 14= Y, there are no inverters. Code 15 specifies the inverter vendor, or if the inverter was field supplied and controlled by the Microtech III Controller.

Code 16 determines if a Smoke Detector is located in the Return Air Cabinet. If Code 16= 1, 3, a Smoke Detector (SD2) is present.

Code 17 determines the type of Enthalpy and Miscellaneous Auxiliary Controls included. The second digit of Code 17 lists the inclusion of Freezstats, Phase Failure, Line Reactors, and Ground Fault protection.

Code 23 (Mid 2012 & Later) indicates the presence of UV/Plenum/Vestibule Lights, the SpeedTrol/Heat Wheel/HGRH inverter brand specified, and/or the presence of Intelligent Equipment.

Code 24 determines if there are Prop Exhaust Fans present and if so, whether it is a 1-fan or 2-fan arrangement.

Code 33 (Mid 2012 & Later) indicates the presence of a Magnehelic/Differential Filter Gauge in a DrawThru or BlowThru section. Refer to Section B (DrawThru Filter Section) for the Gauge part number and description. Code 33 also indicates if the unit is California Title 24 compliant and/or equipped with Ebtron Air Flow Monitors. When Code 33= **S**, **G** an Ebtron Airflow Monitoring Air Monitoring system has been installed. For Ebtron p/ns, contact Daikin Applied with model and serial number information so that the correct part(s) can be identified.

Code 48 determines if the unit is equipped with IBC seismic construction.

Code 49 determines if the Return Air Cabinet has a Light, Switch and Receptacle (Code 49= B, E), Fan Belt Guards (Code 49= D) OR both (Code 49= F).

Page 20: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 20

Ref. Part Actuator Qty. No. Description C20= AE C20= AY 4 Damper Assy- Complete 1 2 1 Damper only 098313701 039813701 1 9 Liner 056132601 056132601 2 10 Panel- Hood Side 056131903 056131903 1 11 Panel- Hood Side 056131904 056131904 1 12 Panel- Hood Top 056131802 056131802 1 13 Louver 056132002 056132002 3 14 Channel- Support 056132303 056132303 2 15 Channel- Support 056132102 056132102 2

Section A1- Outdoor/Return Air Section100% Outside Air Damper with HoodCode 20= AE, AY AND Code 19= YY

No Return Air Plenum

1 This Damper Assy. includes the Damper, Damper Linkage, and Actuator. For Damper Assy. components see the following two pages. For complete Damper Assembly p/ns contact Daikin Applied with model and serial number information so that the correct assembly can be identified.

2 This Damper Assy. includes the Damper and Damper Linkage, but NO Actuator. For Damper Assy. components see the following two pages. For complete Damper Assembly p/ns contact Daikin Applied with model and serial number information so that the correct assembly can be identified.

11

AirFlow

9

15

15

14

12 4

13

9

10

Section B

Page 21: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 21

Section A1- Outdoor/Return Air Section100% Outside Air Damper Detail w/ Act3

Code 20= AE, AY AND Code 19= YYDiagrams

25

27

23

29

26

16

28

24

23

5

7

40

1710

40

20

21421

46

19

22

21

Manual Linkage Detail:Code 20= AY

Motorized Linkage Detail:

Code 20= AE

14

13

17

20

39

1922

Page 22: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 22

Section A1- Outdoor/Return Air Section100% Outside Air Damper Detail w/ ACT3

Code 20= AE, AY AND Code 19= YYComponents

Ref. Part Actuator Qty. No. Description C20= AE C20= AY 4 Shaft- Linkage 055979701 Not Used 2 5 Shaft Assy Not Used 056081001 1 6 Adapter Plate- Crank Arm 403642801 Not Used 1 7 Shaft- Linkage Not Used 055536609 2 10 Channel- Support Not Used 056080601 1 13 Blade- Damper 044195102 044195102 12 14 Grille 055616801 055616801 2 16 Stop-Anti Rotate, Damper 065779801 065779801 2 17 Support- Damper Motor 403642001 Not Used 1 Support- Damper Not Used 056080701 1 19 Linkage Bar Drive Tab 044194900 Not Used 2 20 Crank Arm- Damper 403641901 Not Used 1 Crank Arm- Adjustable Not Used 025072600 1 21 Ball Joint- Damper 000887000 000887000 4 22 Actuator- Motorized, 24V ACT3 113139501 1 Not Used 1 23 Bushing- Linkage Bar, Nylon 046098300 046098300 12 24 Bushing- Damper Blade, Nylon 043730400 043730400 24 25 Gasket- Vinyl 044193115 044193115 12 26 Gasket- Vinyl 045655715 045655715 1 27 Plug- Damper End 041003501 041003501 12 28 Plug- Damper End 041003502 041003502 6 29 Plug- Damper End 041003503 041003503 6 39 Bearing- Flange Sleeve 047138504 Not Used 2 40 Bearing- Sleeve Not Used 047138504 21 Units built early in production used a different Actuator. This is the recommended replacement. When replacing an original

actuator minor field modifications may be required for proper installation and operation.

Page 23: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 23

Section A1- Outdoor/Return Air Section0 - 30% Outside Air Section w/ ACT3

Code 20= BE, BYDiagrams

Linkage Detail:

Without Actuator

Code 20= BY

30

9

3331

32

26

12

8

10

1411

13

15

34

35

15

4813

Linkage Detail:w/ Actuator

Code 20= BE5/12 & Later

Linkage Detail:w/ Actuator

Code 20= BE4/12 & Earlier

47

15

3634

34

35

15

36

48

13

47

15

3634

36

Page 24: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 24

Section A1- Outdoor/Return Air Section0 - 30% Outside Air Section w/ ACT3

Code 20= BE, BYComponents

Ref. Part Actuator Qty. No. Description C20= BE C20= BY Damper Assembly- Complete 1 055600802 2 1 Damper only 098313901 3 098313901 3 1 8 Blade- Damper 044193212 044193212 3 9 Gasket- Vinyl 055940203 055940203 1 10 Gasket- Vinyl 044193124 044193124 3 11 Seal- End 055941901 055941901 2 12 Grille 055593601 055593601 1 13 Support- Motor 4/12 & Earlier 403672201 Not Used 1 Support- Motor 5/12 & Later 403672202 Not Used 1 Rod- Support Angle Not Used 055608601 1 14 Bar- Linkage 055593701 055593701 2 15 Shaft- Linkage 055536608 055536608 1 26 Louver 055593202 055593202 4 30 Plug- End 041003505 041003505 3 31 Plug- End 041003506 041003506 3 32 Bushing- Damper Blade 043730400 043730400 6 33 Bushing- Linkage Bar, Nylon 046098300 046098300 6 34 Ball Joint- Damper 000887000 Not Used 2 35 Actuator- Motorized, 24V ACT3 113139501 4 Not Used 1 36 Crank Arm- Damper 403666401 Not Used 1 47 Bushing- Actuator 047138504 Not Used 1 48 Channel Retainer 4/12 & Earlier 403633801 Not Used 1 Channel Retainer 5/12 & Later 910106063 Not Used 11 Damper assy includes the Damper, Damper Linkage, and Actuator. For the complete Damper Assembly p/n contact Daikin

Applied with model and serial number information so that the correct assembly can be identified.2 Damper assy includes the Damper, Damper Linkage, but NO Actuator.3 Damper only, NO Actuator Linkage OR Actuator.4 Units built early in production used a different Actuator. This is the recommended replacement. When replacing an original

actuator minor field modifications may be required for proper installation and operation.

Page 25: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 25

Section A1- Outdoor/Return Air Section0- 100% Economizer Section with Exhaust Damper

Units w/o Return Air FansCode 20= DE, DY, EE, EY, FE, FY, KE, KY AND Code 21= YYYY

Ref. Part Part Qty. No. Description Number 11 Economizer Damper 1 w/ Act.(Code 20= DE, EE, FE, GE, KE) 2 1 w/o Act. (Code 20= DY, EY, FY, GY, KY) 2 1 12 Exhaust Damper Assembly Powered (Code 20= EE, EY, GE, GY) 112040447 1 Barometric (Code 20= DE, DY, FE, FY, KE, KY) 112039647 11 Economizer detail two pages after next. 2 For the complete Damper Assembly p/n contact Daikin Applied with model and serial number information so that

the correct assembly can be identified.

12

11

Back Return (Code 19= HY) shown.

Air Flow

Page 26: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 26

Section A1- Outdoor/Return Air Section0- 100% Economizer Section with Exhaust Damper

Units with 40” Return Air FansCode 20= DE, DY, EE, EY, FE, FY, GE, GY

Code 21= 40B1, 40B2, 40B3

Ref. Part Part Qty. No. Description Number 11 Economizer Damper 1 w/ Actuator Code 20= DE, EE, FE, GE 2 1 w/o Actuator Code 20= DY, EY, FY, GY 2 1

160 Exhaust Damper Assy. Powered Code 20= EE, EY, GE, GY 055552820 1 Barometric Code 20= DE, DY, FE, FY 055552810 1

50 Belt Guard Code 49= D, F 055962201 1 51 Belt Guard Code 49= D, F 055962202 1 55 Gasket 055921413 2 56 Gasket 055921414 21 Economizer detail on page after next.2 For the complete Damper Assembly p/n contact Daikin Applied with model and serial number information so that

the correct assembly can be identified.

11

Bottom Return (Code 19= BY) shown

5150

55 56

55 56

(See Return Fan Detail)

(See Return Fan Detail)

Air Flow

160

Page 27: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 27

Section A1- Outdoor/Return Air Section0- 100% Economizer Section with Prop Exhaust Fan & Damper

Code 20= HE, HY, JE, JY AND Code 24= 1, 2

20

420

41

15

Section Assembly Detail2 fan arrangement shown

(Code 24= 2)

Fan Guard

Ref. Part Part Qty. No. Description Number 420 Fan Assembly, Std. Motor, 208/230/460V Code 22, 32= **Y 111056601 1, 2

Fan Assembly, Std. Motor, 575V Code 22, 32= **Y 111056602 1, 2

Fan Assembly, Grounded Motor, 208/230/460V Code 22, 32= **S 111056604 1, 2

Fan Assembly, Grounded Motor, 575V Code 22, 32= **S 111056605 1, 2

15 Fan Guard 111181901 1 3

20 Panel- Weather Hood 111173101 1 3

41 Hood- Prop Exhaust 111182301 1 3

N/S Grille Only- Prop Exhaust Hood 111182101 1 3

N/S= Not Shown on diagram.1 See detail following Isolation Damper Detail. 2 Quantity may be one (Code 24= 1) OR two (Code 24= 2).3 Quantity is PER fan.

420

Page 28: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 28

Section A1- Outdoor/Return Air Section0 - 100% Economizer Damper Detail

Code 20= D*, E*, F*, G* H*, J*Diagrams

LinkageDetail:With

Actuator(Code 20= *E)

Linkage Detail:

Without Actuator

(Code 20= *Y)

16 24

13

27

25

28

29

19

23

17

5

1120

22

721

621

4 21

721

6

26

18

24

11

31

123

19

1922

Page 29: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 29

Section A1- Outdoor/Return Air Section0 - 100% Economizer Damper w/ ACT3

Code 20= D*, E*, F*, G* H*, J*Components

Ref. Part Actuator Qty. No. Description C20= *E C20= *Y Damper Assy- Complete 1 055552902 2 1 Damper Assembly 098313201 3 098313201 3 1 4 Shaft Assembly 058390001 Not Used 1 5 Shaft Assembly Not Used 056081001 1 6 Plate- Crank Arm 066302059 Not Used 1 Shaft Assembly Not Used 058390001 1 7 Shaft- Linkage 058389901 058389901 1 11 Channel- Support 403630501 111087501 1 13 Blade- Damper 044195102 044195102 12 16 Stop/Anti-Rotate- Damper 065779801 065779801 4 17 Channel- Support Not Used 111087502 1 18 Bar- Linkage 044194800 044194800 2 19 Drive Tab- Linkage Bar 044194900 044194900 2 20 Crank Arm- Adjustable Not Used 025072600 1 21 Ball Joint- Damper 000887000 000887000 4 22 Actuator- 24V ACT3 113139501 5 Not Used 1 23 Bushing- Linkage Bar 046098300 046098300 12 24 Bushing- Damper Blade 043730400 043730400 24 25 Gasket- Vinyl 044193115 044193115 12 26 Gasket- Vinyl 045655715 045655715 2 27 End Plug- Damper 041003501 041003501 12 28 End Plug- Damper 041003502 041003502 6 29 End Plug- Damper 041003503 041003503 6 31 Bushing- Actuator 047138504 Not Used 1 123 Channel- Actuator 403659701 Not Used 1 N/S Gasket- Neoprene 4 056003501 056003501 4N/S= Not Shown on Diagram.1 Damper Assy. includes the Damper, Damper Linkage, and Actuator. For the complete Damper Assembly p/n contact Daikin

Applied with model and serial number information so that the correct assembly can be identified.2 Damper Assy. includes the Damper and Damper Linkage, but NO Actuator.3 Damper only, NO Actuator Linkage OR Actuator.4 Applied from outer edge of assembly to inside edge of center support and flush with edge of the bottom channel.5 Units built early in production used a different Actuator. This is the recommended replacement. When replacing an original

actuator minor field modifications may be required for proper installation and operation.

Page 30: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 30

Section A1- Outdoor/Return Air SectionCalifornia Title 24 Assembly

Code 33 (Mid 2012 & Later) = *F***

Ref. Part Part Qty. No. Description Number 3533 Cover, Mounting Switch 404159561 1 3534 Bracket, Mounting Switch 404159562 1 3535 Switch, Push Button SPDT 033696300 2 3536 Bushing, Conduit 113116301 1

3533

3536

3534

3535

Page 31: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 31

Section A1- Outdoor/Return Air SectionReturn Air Plenum Isolation Damper w/ Actuator ACT6

Code 19= BE

15

23

3

16

424

20

211822

22

17

19

15

20

ACT6 Actuator Detail

Ref. Part Part Qty. No. Description Number Isolation Damper Assy- Motorized 403718123 1 3 Motor Mount Assembly 055921201 1 4 Blade Assembly- Return, 4” 055921301 9 15 Angle- Linkage 055916702 1 16 Angle- Blade 055638102 1 17 Shaft- Damper Blade 055637801 12 18 Shaft- Linkage 055536601 1 19 Bearing- Flange, Nylon 001113500 12 20 Actuator- Motorized, 24V ACT6 113144901 1 21 Crank Arm- Damper 403717101 1 22 Ball Joint 000887000 2 23 Bearing- Sleeve 047138507 18 24 Gasket- Vinyl 030051979 7 25 Bracket- Support 403716801 1 26 Retainer- Actuator 403717301 1 27 Bearing- Sleeve 047138504 1

21

26

27

25

Page 32: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 32

Section A1- Outdoor/Return Air SectionProp Exhaust Fan & Damper Detail

Code 20= HE, HY, JE, JY AND Code 24= 1, 2

6B

6E

6G6H

6I

Fan Assembly Components2 Fan Arrangement Shown

(Code 24= 2)

Voltage Ref. Sch. Part Part No. Sym. Description Number 1 AFD20 Inverter see charts on following pages 1A Resistor- Inverter 044690105 1 1 1 1 1B Jumper- Inverter 1 055719731 3 3 3 3 6B Fan Prop- 36” 300044027 14 14 14 14

6C Fan Shaft 300044028 14 14 14 14

6D Bearing 300044029 24 24 24 24

6E Fan Sheave 019291400 14 14 14 14

6F Bushing- Fan Sheave 000804000 14 14 14 14

6G Belt 049260805 24 24 24 24

6H Motor Sheave 000607600 14 14 14 14

6I Motor 300046887 14 14 14

Motor 300046251 14

51 Tube- Plastic 2 020954800 8’ 8’ 8’ 8’ 53 Coupling- Tube 2 .25 x .125 FPT 021213800 2 2 2 2 54 Fitting- Grease 2 000109800 2 2 2 2 1B Jumper- Inverter 1 055719731 3 3 3 3 420 Fan Assembly, Std. Mtr. Code 22, 32= **Y 111056601 4 4 4

Fan Assembly, Std. Mtr. Code 22, 32= **Y 111056602 4

Fan Assembly, Grd. Mtr. Code 22, 32= **S 111056604 4 4 4

Fan Assembly, Grd. Mtr. Code 22, 32= **S 111056605 4

420A Damper- Backdraft 3

208V

230V

460V

575V

54

53

51

Lube Line Detail

11A

1B

Control Box(see following page

6C 6D

6F

1 Quantity= 2 when Inverter model 3500 (Code 15= G) is used.2 Quantity shown is for 1 fan (Code 24=1). Quantities for 2 fan units (Code 24= 2): Ref. 51= 25’; Ref. 53= 4; Ref. 54= 4.3 Contact Daikin Applied.4 Quantity is PER fan.

420420A

Page 33: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 33

Section A1- Outdoor/Return Air SectionProp Exhaust Fan & Damper Detail

Code 20= HE, HY, JE, JY AND Code 24= 1, 2Continued

220

230

2 Fan Unitshown.

Voltage Ref. Sch. Part Part No. Sym. Description Number 220 OL51, 52 Overload 349934663 2 Overload 349934662 2 Overload 349934660 2 Overload 349934659 2 230 M51, 52 Contactor 349932123 2 2 Contactor 349932121 2 2

208V

230V

460V

575V

OL51 OL52

M51 M52

NOTE: Quantities listed are for a 2 Fan unit (Code 24= 2).

Contactors &Overloads

Detail

Voltage Code Inverter Model Part 15= Number A 550 112046015 1 1 550 112046002 1 G 3500 098656916 1 3500 098656926 1 3500 098656903 1 3500 098656943 1 R VTAC9 111046868 1 1 VTAC9 111046854 1 S MD2 349956609 1 1 MD2 349956625 1

208V

230V

460V

575V

Inverter- 1 Fan Units (Code 24= 1) Voltage Code Inverter Model Part 15= Number A 550 112046017 1 1 550 112046004 1 G 3500 098656918 1 3500 098656928 1 3500 098656905 1 R VTAC9 111046870 1 1 VTAC9 111046856 1 S MD2 349956611 1 1 MD2 349956627 1

208V

230V

460V

575V

Inverter- 2 Fan Units (Code 24= 2)

Prop Exhaust Fan Control Box

03/13 & Earlier

Page 34: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 34

Section A1- Outdoor/Return Air SectionProp Exhaust Fan & Damper Detail

Code 20= HE, HY, JE, JY AND Code 24= 1, 2Continued

04/13 & Later

Voltage Code Inverter Model Part 15= Number A 550 112046015 1 1 550 112046002 1 B MD4 193552215 1 1 MD4 193552202 1 G 3500 205858812 1 1 3500 205858822 1 3500 205858843 1 Q MD2 193552215 1 1 MD2 193552202 1 R VTAC9 111046868 1 1 VTAC9 111046854 1 S MD2 193475809 1 1 MD2 193475825 1

208V

230V

460V

575V

Inverter- 1 Fan Units (Code 24= 1) Voltage Code Inverter Model Part 15= Number A 550 112046017 1 1 550 112046004 1 B MD4 193552217 1 1 MD4 193552204 1 G 3500 098656918 1 3500 098656928 1 3500 098656905 1 Q MD2 193552215 1 1 MD2 193552202 1 R VTAC9 111046870 1 1 VTAC9 111046856 1 S MD2 193475811 1 1 MD2 193475827 1

208V

230V

460V

575V

Inverter- 2 Fan Units (Code 24= 2)

220

230

2 Fan Unit shown

Voltage Ref. Sch. Part Part No. Sym. Description Number 220 OL51, 52 Overload 193548010 2 Overload 193548009 2 Overload 193547910 2 Overload 193547909 2 230 M51, 52 Contactor 25A 193537304 2 Contactor 16A 193592006 2 Contactor 9A 193534106 2 Contactor 7A 193534105 2

208V

230V

460V

575V

OL51 OL52

M51 M52

220

230

Prop Exhaust Fan Control Box

NOTE: Quantities listed are for a 2 Fan unit (Code 24= 2).

Page 35: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 35

Section A1- Outdoor/Return Air SectionDesign Flow

Code 20= FE, FY, GE, GY, JE, JY

Ref. Part Part Qty.1

No. Description Number 1 Louver Panel Left Hand Door 059595204 10 Louver Panel Right Hand Door 059595203 10 2 Grille 055541401 1 3 Gasket 055921402 2 4 Gasket 055921401 1 9 Potentiometer 098663701 1 12 O-Ring, Potentiometer 098663801 1 104 Panel- Vane 098661802 1 105 Shaft- Upper 098662601 1 106 Bearing- Lower 091634501 1 109 Crank Arm Assy Left Hand Door 091658802 1 Crank Arm Assy Right Hand Door 091658801 1 110 Link Arm 2 1 120 Bearing 060014201 1 127 Bearing 047138535 1 130 Spring- Main .75” x 2” 098664801 1 131 Spring- Secondary .30” x 1.5” 098664901 1 N/S Leveling Kit- Design Flow 091659301 1

2

9 127

12

110120 109 104

105

106

131

130104

1

Section Final Assembly

Design Flow Vane and Vane Bearings Detail

Adjuster Control AssyDetail

SpringDetail

LH Louvered Door Assy

RH Louvered Door Assy

Louvered DoorAssembly Detail

3➤

4

1 Quantity is PER door.2 P/N is unit specific. Contact Daikin Applied with overall length and bolt hole spacing so that the correct part can be

identified.

Page 36: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 36

Section A1- Outdoor/Return Air Section40” Return Air Fan (Code 21= 40B*) 1

Ref. Part Part Qty. No. Description Number 1 Motor see tables one & two pages after next Fan Housing Assy- Inlet Funnel 031940905 1 2 Inlet Funnel 031940905 1 6 Wheel- Air Foil Fan, SI/SW 40” 066543242 1 7 Mount- Motor 055552401 1 13 Shaft 1.937” Diameter 055541902 1 15 Coupling 1/8” MPT 027674000 2 16 Coupling- Reducer 1/4” X 1/8” FPT 021213800 2 17 Tubing- Plastic 021136745 2 19 Grease Fitting 1/8” MPS 000109800 2 20 Bearing- Ball 1.937” bore 020648603 2 26 Key- Wheel 1/2” X 5 1/2” 023221513 1 27 Key- Fan Sheave 1/2” X 4 1/2” 023221507 1

1

7

272613

6

15 1716 20

1520 161719

1 Mounting type, fourth digit: 1= RIS, 2= Spring, 3= Spring w/ Seismic Snubbers.

2

Page 37: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 37

Section A1- Outdoor/Return Air SectionReturn Air Fan Mounts (Code 21= 40B*)

Ref. Fan Motor Part Part Qty. No. HP Description Number 121 All Mount Spring Code 21= 40B2 251783201 4 Seismic Code 21= 40B3 251783301 4 161 2 Spring Mount- Yellow 251784501 1 3, 5 Spring Mount- Yellow 251784601 1 7.5- 15 Spring Mount- Green 251784701 1 20- 30 Spring Mount- Dark Brown 251784801 1 162 2, 15, 20, 25 Spring Mount- Dark Brown 251784801 1 3- 10 Spring Mount- Green 251784701 1 30 Spring Mount- Red 251784901 1 163 2- 5 Spring Mount- Yellow 251784501 1 7.5- 30 Spring Mount- Blue 251784401 1 164 2 Spring Mount- Dark Brown 251784801 1 3- 7.5 Spring Mount- Yellow 251784601 1 10- 20 Spring Mount- Yellow 251784501 1 25, 30 Spring Mount- Blue 251784401 1 181 All Nut Spring Code 21= 40B2 059992201 12 Seismic Code 21= 40B3 111056301 20 188 All Nut 040500002 4 189 All Screw Spring Code 21= 40B2 112047201 12 Seismic Code 21= 40B3 112047201 20

Spring Mounts (Code 21= 40B2) & Seismic Spring (40B3)

Ref. Fan Motor Part Part Qty. No. HP Description Number 21 All Channel- Mount Support 055512101 4 61 2 - 20 Rubber Mount- Black 021639704 1 25, 30 Rubber Mount- Red 021639701 1 62 2 - 10 Rubber Mount- Black 021639704 1 15 - 30 Rubber Mount- Red 021639701 1 63 2 - 30 Rubber Mount- Black 021639704 1 64 2 - 30 Rubber Mount- Black 021639704 1 81 All Nut 059992201 8 89 All Screw 112047201 8 91 All Nut- 1/2-13 032333305 12 92 All Screw- Cap, 1/2-13 X 1” 040499501 8 93 All Washer- Plain, 1/2” 040500310 8

Rubber Mounts (Code 21= 40B1)

Rubber Mounts

64

61

62

Mounting Diagram

Spring Mounts

161 or

163 or 63

164 or

162or

92

93

89

81 91

21

61 62

63 64

91

161 162

163 164

188

189

181

121

Seismic strap used only when Code 21= 40B3.

Page 38: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 38

H.P. Motor H.P. Unit ODP HiEff ODP PrEff. TEFC HiEff TEFC PrEff Motor Code 22= Voltage C22= *EY C22= *JY C22= *HY C22= *KY Mount 1

C09= 12 2 G*Y 208/60/3 039895700 046515500 049100300 073321000 073316604 3 H*Y 208/60/3 039447500 065817100 047358100 065819400 073316605 5 J*Y 208/60/3 039447600 065817200 049186800 065819500 073316606 7.5 K*Y 208/60/3 037530300 065817300 047665900 065819600 073316607 10 L*Y 208/60/3 038999000 065817400 047666100 065819700 073316608 15 M*Y 208/60/3 039896200 065817500 049186900 065819800 073316609 20 N*Y 208/60/3 039895800 065817600 049187000 065819900 073316610 25 P*Y 208/60/3 039448900 065817700 049187100 065820000 073316611 30 Q*Y 208/60/3 041775200 205066500 049187200 205066800 073316612 C09= 29 2 G*Y 230/60/3 039446300 205163500 047446000 073321000 073316604 3 H*Y 230/60/3 039442400 065818100 049262300 065820100 073316605 5 J*Y 230/60/3 039442500 065818200 040161200 065820200 073316606 7.5 K*Y 230/60/3 039448700 065818300 049100500 065820300 073316607 10 L*Y 230/60/3 039446500 065818400 044691100 065820400 073316608 15 M*Y 230/60/3 039446600 065818500 038689700 065820500 073316609 20 N*Y 230/60/3 039448800 065818600 040161300 065820600 073316610 25 P*Y 230/60/3 039896100 065818700 040161400 065820700 073316611 30 Q*Y 230/60/3 040626800 205066600 049025300 205066900 073316612 C09= 27 2 G*Y 460/60/3 039446300 205163500 047446000 073321000 073316604 3 H*Y 460/60/3 039442400 065818100 049262300 065820100 073316605 5 J*Y 460/60/3 039442500 065818200 040161200 065820200 073316606 7.5 K*Y 460/60/3 039448700 065818300 049100500 065820300 073316607 10 L*Y 460/60/3 039446500 065818400 044691100 065820400 073316608 15 M*Y 460/60/3 039446600 065818500 038689700 065820500 073316609 20 N*Y 460/60/3 039448800 065818600 040161300 065820600 073316610 25 P*Y 460/60/3 039896100 065818700 040161400 065820700 073316611 30 Q*Y 460/60/3 040626800 205066600 049025300 205066900 073316611 C09= 37 2 G*Y 575/60/3 049181000 205168300 049188200 046514400 073316604 3 H*Y 575/60/3 046741600 046511700 049188300 046514500 073316605 5 J*Y 575/60/3 046741900 205168900 049188400 046514600 073316606 7.5 K*Y 575/60/3 047443300 205168800 049188500 046514700 073316607 10 L*Y 575/60/3 047443400 205168600 049188600 065821400 073316608 15 M*Y 575/60/3 047443500 205166600 049185200 065821500 073316609 20 N*Y 575/60/3 049181100 205166800 049188700 065821600 073316610 25 P*Y 575/60/3 049181200 205166900 049188800 065821700 073316611 30 Q*Y 575/60/3 049181300 205066700 049188900 205067000 0733166121 Note that the Return Fan Motor Mounts listed are used ONLY in Heat Recovery units when Code 21= 40B* AND Code 20=

3*, 4*, 5*, 6*. See the 40” Return Fan Detail in Section A2- Outdoor/Return Air w/ Heat Recovery Section.

Section A- Outdoor/Return Air SectionReturn Air Fan Motors

Standard Motors: Code 22= **Y

Page 39: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 39

Section A- Outdoor/Return Air SectionReturn Air Fan Motors

Shaft Grounded Motors: Code 22= **S 1

H.P. Motor HP Unit ODP PrEff. TEFC PrEff C22= **S Voltage C22= *JS C22= *KS C09= 12 2 G*S 208/60/3 046515599 N/A 3 H*S 208/60/3 300052109 065819499 5 J*S 208/60/3 300052118 065819599 7.5 K*S 208/60/3 065817399 065819699 10 L*S 208/60/3 065817499 065819799 15 M*S 208/60/3 065817599 065819899 20 N*S 208/60/3 065817699 065819999 25 P*S 208/60/3 065817799 065820099 30 Q*S 208/60/3 205066599 205066899 C09= 29 2 G*S 230/60/3 300049697 300049687 3 H*S 230/60/3 300049698 300049688 5 J*S 230/60/3 300049699 300049689 7.5 K*S 230/60/3 300049700 300049690 10 L*S 230/60/3 300049701 065820499 15 M*S 230/60/3 065818599 300049198 20 N*S 230/60/3 065818699 300049691 25 P*S 230/60/3 300049702 300049692 30 Q*S 230/60/3 300049703 205066999 C09= 27 2 G*S 460/60/3 300049697 300049687 3 H*S 460/60/3 300049698 300049688 5 J*S 460/60/3 300049699 300049689 7.5 K*S 460/60/3 300049700 300049690 10 L*S 460/60/3 300049701 065820499 15 M*S 460/60/3 065818599 300049198 20 N*S 460/60/3 065818699 300049691 25 P*S 460/60/3 300049702 300049692 30 Q*S 460/60/3 300049703 205066999 C09= 37 2 G*S 575/60/3 205168399 046514499 3 H*S 575/60/3 046511799 205168499 5 J*S 575/60/3 205168999 046514699 7.5 K*S 575/60/3 205168899 046514799 10 L*S 575/60/3 205168699 065821499 15 M*S 575/60/3 205166699 065821599 20 N*S 575/60/3 205166899 065821699 25 P*S 575/60/3 205166999 065821799 30 Q*S 575/60/3 098865399 205067099N/A= Not Available.1 For Return Fan Motor Mounts used in Heat Recovery units (when Code

21= 40B* AND Code 20= 3*, 4*, 5*, 6*) refer to the previous page.

Page 40: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 40

Section A1- Outdoor/Return Air SectionSection Mounted Controls

OAE, RAE, LT11, S11, REC11

Ref. Part Part Qty. No. Description Number 84 Light Fixture 042229500 1 85 Bulb- LT11 065492402 1 88 Light Switch- S11 065492201 1 89 Receptacle- REC11 030187000 1

LT11- Return Fan Light/S11- Return Fan Light Switch/REC11- Return Fan ReceptacleCode 49= E, F

Return Air Opening

30

Return Air

Opening

30

Ref. Part Part Qty. No. Description Number 30 Smoke Detector- SD2 098873101 1

SD2- Return Air Smoke DetectorCode 16= 1, 3

Back ReturnCode 19= HY

Bottom ReturnCode 19= BY, BE

7

Ref. Part Part Qty. No. Description Number 7 Sensor- RAT 193414602 1

RAT- Outdoor Air Temperature Sensor

84 85

88 89

Ref. Part Part Qty. No. Description Number 40 Mount- OAE Enthalpy 1 1 41 Control- OAE 1 1

40OAE- Mechanical Enthalpy (Code 17= Y*)

41

Ref. Part Part Qty. No. Description Number 40 Mount- OAE Enthalpy 2 1 41 Control- OAE 2 1 42 Mount- RAE Enthalpy 2 1 48 Control- RAE 2 1

OAE & RAE Differential Enthalpy (Code 17= C*)

48

42

Economizer Damper

Bottom ReturnShown

Code 19= BY, BE

Bottom ReturnShown

Code 19= BY, BE

1 The original control is obsolete & no longer available. For the OAE Control use p/n 113103601 & Mount 910146257. Minor field modifications are required for proper installation & operation when changing to the newer design.

2 BOTH original controls are obsolete & no longer available. For the OAE Control use 113103601 & Mount 910146257. For the RAE Control use 113103701 & Mount 055732301. Note that when changing out EITHER ONE of the older style controls BOTH CONTROLS MUST BE CHANGED TO THE NEWER VERSION. When upgrading to the new style controls, field modifications, including the installation of Relay 349934722 (OAER), are required for proper installation & operation.

Economizer Damper

40

41

Page 41: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 41

Section A2- Outdoor/Return Air w/ Heat Recovery SectionNotes

Primary Codes that pertain: 19, 20, 21, 22, 23 (Mid 2012 & Earlier); 24, 58 (Mid 2012 & Later)Additional Codes that pertain: 06, 09, 14, 15, 16, 17, 48, 49; 23, 33 (Mid 2012 & Later)

Codes 19 and 20 determine the base section. Code 19 is the Return Air Plenum; Code 20 determines the type of Outdoor Air/Heat Recovery control used. When Code 20= 3E, 5E the unit has a 6” Heat Recovery Wheel. If Code 20= 4E, 6E the unit has a 12” Heat Recovery Wheel.

Codes 21, 22, 23 (Mid 2012 & Earlier), and 58 (Mid 2012 & Later) determine the Return Air Fan, Fan Motor and drive selection. The fan section parts, the Fans, and the Motors are listed in this section. Drive components (Fan Sheave, Motor Sheave, V-belt(s), and Sheave Bushing(s) [if required]) are NOT listed as they are unique to the unit. If a drive component is required you may use the number from the part and cross reference it in the Daikin Applied Parts catalog, The Daikin Parts E-Commerce site, or contact Daikin Applied with model and serial number information. The motors range from 2- 30 horsepower, and the Fan is a 40” Single width Airfoil Wheel.

Code 24 determines if the Heat/Energy Recovery Wheel has a Frost Protection Inverter.

Code 06, insulation and liners, influences the final cabinet assembly panel part numbers. For sheet metal components that make up the Outdoor/Return Air Section, contact Daikin Applied with model and serial number information to ensure that the correct liners, insulation and hardware are ordered. For standard Access Door Latching Assemblies, see Section H.

Code 09, the voltage, is part of the Return Fan Motor part number identification.

Codes 14 & 15 determine if the unit has inverter(s) and if so where they are installed. If Code 14= 3, 5, 6, 7, 8, 9 the inverter(s) are installed in the Supply Air Section. If Code 14= 1, 2, 4 AND Code 26= S, there is a separate Inverter Section. If Code 14= Y, there are no inverters. Code 15 determines the Inverter Vendor. For inverter part numbers, refer to the Supply Air Section (Section F).

Code 16 determines if a Smoke Detector is located in the Return Air Cabinet. If Code 16= 1, 3, a Smoke Detector (SD2) is present.

Code 17 determines the type of Enthalpy and Miscellaneous Auxiliary Controls included. If Code 17= C*, the unit is equipped with Differential Enthalpy Control. The second digit of Code 17 lists the inclusion of Freezstats, Phase Failure, Line Reactors, and Ground Fault protection.

Code 23 (Mid 2012 & Later) indicates the presence of UV/Plenum/Vestibule Lights, the SpeedTrol/Heat Wheel/HGRH inverter brand specified, and/or the presence of Intelligent Equipment.

Code 33 (Mid 2012 & Later) indicates the presence of a Magnehelic/Differential Filter Gauge in a DrawThru or BlowThru section. Refer to Section B (DrawThru Filter Section) for part numbers and descriptions. When Code 33= **S**, **G** an Ebtron Airflow Monitoring Air Monitoring system has been installed. For Ebtron p/ns, contact Daikin Applied with model and serial number information so that the correct part(s) can be identified.

Code 48 determines if the unit is equipped with IBC seismic construction.

Code 49 determines if the Return Air Cabinet has a Belt Guard (Code 49= D), OR a Belt Guard and a Fan Section Light (Code 49= F).

Page 42: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 42

Cabinet Gaskets, Doors and Exhaust Hoods

(LH components shown)439

440

437437

Exhaust Hood- See Detail to Left

420

421 437 414

418

502

503

505

504

Section A2- Outdoor/Return Air w/ Heat Recovery SectionCabinet Gaskets, Doors, Hardware, Exhaust Hoods

Code 20= 3E, 4E, 5E, 6E

Ref. Part Part Qty. No. Description Number 414 Hinge 032457700 2 415 Door 24” 111208802 4 418 Door- Exhaust 48” 111209601 1 419 Door- Exhaust 48” 111209602 1 420 Door 24” 111208801 4 421 Door 48” 111209202 1 423 Door 48” 111209201 1 437 Gasket- Vinyl 055921411 24 439 Gasket- Vinyl 055921409 12 440 Gasket- Vinyl 055921408 24 502 Damper- Back Draft 39.38 x 31.25 111209301 2 503 Panel- Hood 111209802 2 504 Panel- Hood RH 111074702 2 505 Panel- Hood LH 111074602 2

437418

437

414

423

415Hoo

d419

Page 43: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 43

Section A2- Outdoor/Return Air w/ Heat Recovery SectionBase Components, Hood, Dampers

Code 20= 3E, 4E, 5E, 6E

144

142

145 146 141

148140

See Hood Detail to Left

Outdoor Air Intake Hood Detail

230

160

230

2011

31

30

202

211

205

211

204

12A210215

210215

12

Base Assembly

Ref. Part Part Qty. No. Description Number 1 Fan Assembly 1

12 Damper- OA Low Leak w/ Actuator ACT3 2 1 12A Damper- RA Low Leak w/ Actuator ACT4 2 1 30 Channel- Fan 251849801 1 31 Channel- Fan 251849901 1 140 Panel- Outdoor Intake Hood, Top 251840701 1 141 Panel- Outdoor Intake Hood, Side 251841101 1 142 Panel- Outdoor Intake Hood, Side 251841201 1 144 Louver- Outdoor Intake Hood 251840801 1 145 Louver- Outdoor Intake Hood 251840901 1 146 Louver- Outdoor Intake Hood 251841001 1 148 Screen- Outdoor Intake Hood 251841801 2 160 Wheel, Enthalpy- Heat Recovery 3

201 Filter Rack- Upper LH 251846701 1 202 Filter Rack- Upper RH 251846702 1 204 Filter Rack- Lower LH 251846602 1 205 Filter Rack- Lower RH 251846601 1 210 Filter- 30% 16 x 20 x 2 031298001 14 211 Filter- 30% 16 x 25 x 2 031298002 42 215 Stop- Filter 011484101 14 230 Damper- “L” Bypass w/ Actuator ACT12, 13 4 21 See detail on following page.2 See detail following Fan Mount detail.3 See detail following “L” Bypass Damper detail.4 See detail following Low Leak Damper detail.

Page 44: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 44

Section A2- Outdoor/Return Air w/ Heat Recovery Section40” Return Air Fan (1/12 & Earlier)

10A

10B

7

10

11

1

10C

Ref. Part Part Qty. No. Description Number 1 Motor 1

7 Gasket 251851101 1 10 Fan Assembly 209994902 1 10A Fan Wheel 010255226 1 10B Bearing- Inlet Side 020648654 1 N/S Bearing- Drive Side 300043930 1 10C Shaft 010288112 1 11 Motor Mount 1 1 40 Angle- Thrust Restraint 110916701 1 41 Spring Mount, Floor- Thrust Restraint Red 059397901 1N/S= Not Shown on diagram.1 See Return Air Fan Motor Tables.

40

41

Thrust Restraint Detail

Page 45: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 45

Section A2- Outdoor/Return Air w/ Heat Recovery Section40” Return Air Fan Mounts (1/12 & Earlier)

35B

35C 35D

35A

81

84

84

76235A

Fan Channel

87

8681

84

35B 35C

35D

Fan Mounting Locations

Spring (Code 21= 40B2) ORSpring w/ Seismic Snubber (Code 21= 40B3)

Mounting Detail

37

Top View

Rubber-In-Shear (Code 21= 40B1) Mounting Detail

504226 441 227

510

35A 35B35C 35D

Fan Channel

Ref. Motor Part Part Qty. No. HP Description Number 35A 2- 5 Vibration Mount Green 073310901 1 7.5- 25 Vibration Mount Gray 073311001 1 35B All Vibration Mount Green 073310901 1 35C 2- 10 Vibration Mount Red 073310801 1 15- 25 Vibration Mount Green 073310901 1 35D 2- 10 Vibration Mount Green 073310901 1 15- 25 Vibration Mount Gray 073311001 1 81 Nut- Hex 032333305 4 84 Nut- Hex 032333304 8 226 Screw 046093820 8 227 Screw 040501412 8 441 Nut- Hex 032333304 4 504 Washer 040500310 8 510 Washer 040500307 8 762 Support 057862601 1/mt

Ref. Part Part Qty. No. Description Number 35A All Vibration Mount Yellow 059398201 1 35B 2, 3 Vibration Mount Green 059398001 1 5- 25 Vibration Mount Gray 059398101 1 35C 2- 15 Vibration Mount Green 059398001 1 20, 25 Vibration Mount Gray 059398101 1 35D 2- 5 Vibration Mount Gray 059398101 1 7.5- 25 Vibration Mount Yellow 059398201 1 37 Mount- Seismic 1 059478401 4 81 Nut- Hex 032333305 8 84 Nut- Hex, Spring Code 21= 40B2 032333304 8 Nut- Hex, Seismic Code 21= 40B3 032333304 16 86 Screw- Cap 1 048878118 8 87 Washer 1 040500308 81 Seismic snubber parts only (Code 21= 40B3).

Page 46: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 46

Section A2- Outdoor/Return Air w/ Heat Recovery Section40” Return Air Fan (2/12 & Later)

432411

072

452

490

434

Ref. Part Part Qty. No. Description Number 072 Inlet Funnel 251851101 1 411 Bearing, Roller- Drive Side 2 3/16” 300042661 1 412 Bearing, Ball- Inlet Side 2 3/16” 020648654 1 432 Shaft, 2 3/16” 113174340 1 434 Key 023221518 1 452 Fan Wheel 206007740 1 490 Motor Mount 1 11 See Return Air Fan Motor Section.

Motor 1

412

Page 47: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 47

Section A2- Outdoor/Return Air w/ Heat Recovery Section40” Return Air Fan Mounts (2/12 & Later)

Ref. Fan Motor Part Part Qty. No. HP Description Number 34 2- 5 Spring Mount- Green 251784701 1 7.5- 30 Spring Mount- Dark Brown 251784801 1 35 2- 10 Spring Mount- Dark Brown 251784801 1 15, 20 Spring Mount- Red 251784901 1 30 Spring Mount- Tan 251785001 1 36 2- 7.5 Spring Mount- Dark Brown 251784801 1 10- 30 Spring Mount- Red 251784901 1 37 2- 30 Spring Mount- Dark Brown 251784801 1 38 All Mount Spring Code 21= 40B2 251783201 4 Seismic Code 21= 40B3 251783301 4 40 All Nut, Clinch 059992201 24 41 All Screw, 3/8-16 x 1.5” 112047201 8

Spring Mounts (Code 21= 40B2) & Seismic Spring (40B3)

Ref. Fan Motor Part Part Qty. No. HP Description Number 34- 36 All Rubber Mount- Red 021639701 4 38 All Channel- Mount Support 404079350 4 40 All Nut, Clinch 059992201 24 41 All Screw, 3/8-16 x 1.5” 112047201 8 42 All Screw, 5/16-18 040501412 8 44 All Nut- 1/2-13 032333305 8 49 All Washer- Plain, 1/2” 040500310 4 50 All Screw, Cap 040499501 12

Rubber Mounts (Code 21= 40B1)

Rubber Mounts

34

Mounting Diagram

Spring Mounts

3635

37

44

42

40

41

49

38

34 35

36 37

50

41

40

38

Seismic strap used only when Code 21= 40B3.

34 35

36 37

Page 48: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 48

Section A2- Outdoor/Return Air w/ Heat Recovery SectionLow Leak Damper Detail (Ref. #12, 12A)

with ACT3 (Outside Air) OR ACT4 (Return Air)MicroTech III Controls (Code 12= *E, *F, *W)

122

119

127

116

114

126

127

125

128

129

120

116

128

ACT3 OR ACT4

Ref. Part Part Qty. No. Description Number Complete Assy w/ Actuator 111206409 Complete Assy- Less Actuator 251868501 114 Seal- End 043734314 2 116 Stop- Damper 047110101 2 119 End Plug 057783404 1 120 Blade- Damper 047793308 4 122 Actuator, 24V ACT3, 4 113139501 1 1 125 End Plug 041003508 4 126 End Plug 041003509 3 127 Bushing- Linkage 046098300 6 128 Bushing- Damper Blade 043730400 5 129 Shaft- Drive 043734000 2 N/S Gasket- Vinyl 044193135 4 N/S Gasket- Vinyl 055940221 1N/S= Not Shown on diagram.NOTE- The drawing is a generic illustration of this damper type, and shows part

location, but does not show the actual part quantities listed in the table.1 Units built early in production used a different Actuator. This is the

recommended replacement. When replacing an original actuator minor field modifications may be required for proper installation and operation.

Page 49: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 49

22

23

Ref. Part Part Qty. No. Description Number Complete Assembly w/ Actuator 251849329 Complete Assembly w/o Actuator 251847129 12 Blade- Damper 251853801 5 13 Blade- Damper 251848801 1 16 Linkage- Channel 251848901 1 17 Gasket- Vinyl 055940222 1 18 Gasket- Vinyl 044193136 5 19 Gasket- Vinyl 044193137 1 20 Plug, End- Damper 041003503 6 21 Plug, End- Damper 041003501 5 22 Stop- Damper 047110101 1 23 Bushing- Damper Blade 043730400 11 24 Bushing- Linkage Bar 046098300 6 25 End Plug- Damper 251854301 1 26 Lock Collar 049115902 1 27 Bushing- Drive Shaft 043734000 1 122 Actuator, 24V ACT12, 13 113145001 1

Section A2- Outdoor/Return Air w/ Heat Recovery SectionBypass “L” Type Damper Detail

w/ ACT12 (Outside Air) OR ACT13 (Return Air) (Ref. # 230)MicroTech III Controls (Code 12= *E, *F, *W)

21

25

20

16

23

12 18

26

27

21

17

13

24

19

Actuator Detail

122ACT12 OR ACT13

Page 50: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 50

Section A2- Outdoor/Return Air w/ Heat Recovery SectionHeat Recovery/Enthalpy Wheel

Wheel, Motor, Drive Components, Seals

Outdoor Air Out (Supply)

Exhaust Air In (Return) 163161

164

162

165

Ref. Part Part Qty. No. Description Number Wheel Assy- Complete 1 208/230/460V 113073801 1 575V 113087901 1 Segmented Wheel 2 300043261 1 161 Motor 208/230/460V 300043699 1 575V 300043263 1 162 Sheave 111048001 1 163 Bearing 300043258 2 164 Shaft 300043265 1 165 Belt 300043249 1 N/S Inner Seal 300043252 2 N/S Outer Seal 300043252 3N/S= Not Shown on diagram.1 Includes motor, shaft, belt etc.2 If a replacement wheel is required, it is suggested that this part number be used. The segmented wheel ships disassembled which allows for

easier shipping and installation.

Low Air Flow ERW (Code 20= 3E, 5E)- 6” Wheel

Ref. Part Part Qty. No. Description Number Wheel Assy- Complete 1 208/230/460V 113073901 1 575V 113088001 1 Segmented Wheel 2 300043262 1 161 Motor 208/230/460V 300043699 1 575V 300043263 1 162 Sheave 300043260 1 163 Bearing 300043258 2 164 Shaft 300043266 1 165 Belt 300043249 1 N/S Inner Seal 300043252 2 N/S Outer Seal 300043252 3

High Air Flow ERW (Code 20= 4E, 6E)- 12” Wheel

Page 51: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 51

Section A2- Outdoor/Return Air w/ Heat Recovery SectionAFD60 Frost Protection Inverter (Code 24= F)

3

Voltage Ref. Sch. Part Part No. Sym. Description Number 3 VFD60 Inverter 193475806 2 1 1 VFD60 Inverter 193475822 2 1 VFD60 Inverter 349956738 2 1

208V

230V

460V

575V

208V

230V

460V

575V

Mid 2012 & Later

Mid 2012 & Earlier 1

1 In Mid 2012 the Unit Model Nomenclature was changed to code the different Inverter brands offered. Before this date ATV21 OR ATV212 drives (see note below) were standard.

2 In 2010 the original ATV21 Inverters were replaced with ATV212 Inverters as listed above. These Inverters are drop in replacements with the exception of the Remote Keypad and Communication Cards. If a Communication card OR Remote Keypad is required, contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. Note that since the original ATV21 drives are obsolete and unavailable, when at zero stock, repair parts are also not available. If an obsolete ATV21 part fails, the entire drive must be replaced.

Voltage Ref. Sch. Part Part No. Sym. Description Number 3 Code 23= **A** 3

VFD60 Inverter 4 099488103 1 1 Inverter 4 099488004 1 Inverter 4 112046026 1 Code 23= **B** 3

VFD60 Inverter 4 193552245 1 1 Inverter 4 193552295 1 Inverter 4 193552326 1 Code 23= **Q** 3

VFD60 Inverter 193475806 1 1 Inverter 193475822 1 Inverter 193456302 13 For the fusing for VFD60, refer to the "Heat/Energy Recovery Wheel Contactors, MMPs & Fusing 04/13 & Later"

page in Section N. 4 The replacement VFD Keypad is p/n 300040924.

Heat Wheel

Page 52: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 52

Section A2- Outdoor/Return Air w/ Heat Recovery SectionSection Mounted ControlsOAE, RAE, RAT, EAT, LAT

184

Ref. Part Part Qty. No. Description Number 184 Support- RAT 111077601 1 200 RA Sensor- RAT 193414602 1

RAT- Outdoor Air Temperature Sensor

RA Open-

ing

200

Deck Panel

Return Fan

500 422

600 582

Ref. Part Part Qty. No. Description Number 422 Support- EAT 111077601 1 500 RA Sensor- EAT 193414602 1

EAT- Outdoor Air Temperature Sensor

Ref. Part Part Qty. No. Description Number 582 Support- LAT 111078001 1 600 Sensor- LAT 193414602 1

LAT- Leaving Air Temperature Sensor

40

41

48

42

Economizer Damper

Bottom ReturnShown

Code 19= BY, BE

Bottom ReturnShown

Code 19= BY, BE

Economizer Damper

40

41

Ref. Part Part Qty. No. Description Number 40 Mount- OAE Enthalpy 1 1 41 Control- OAE 1 1

OAE- Mechanical Enthalpy (Code 17= Y*)

Ref. Part Part Qty. No. Description Number 40 Mount- OAE Enthalpy 2 1 41 Control- OAE 2 1 42 Mount- RAE Enthalpy 2 1 48 Control- RAE 2 1

OAE & RAE Differential Enthalpy (Code 17= C*)

1 The original control is obsolete & no longer available. For the OAE Control use p/n 113103601 & Mount 910146257. Minor field modifications are required for proper installation & operation when changing to the newer design.

2 BOTH original controls are obsolete & no longer available. For the OAE Control use 113103601 & Mount 910146257. For the RAE Control use 113103701 & Mount 055732301. Note that when changing out EITHER ONE of the older style controls BOTH CONTROLS MUST BE CHANGED TO THE NEWER VERSION. When upgrading to the new style controls, field modifications, including the installation of Relay 349934722 (OAER), are required for proper installation & operation.

Page 53: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 53

Ref. Part Part Qty. No. Description Number 84 Light Fixture 042229500 1 85 Bulb- LT11 065492402 1 88 Light Switch- S11 065492201 1 89 Receptacle- REC11 030187000 1

LT11- Return Fan Light/S11- Return Fan Light Switch/REC11- Return Fan ReceptacleCode 49= E, F

230

227

Ref. Part Part Qty. No. Description Number 227 Support- SD2 111079701 1 230 Smoke Detector- SD2 098873101 1

SD2- Return Air Smoke DetectorCode 16= 1, 3

Section A2- Outdoor/Return Air w/ Heat Recovery SectionSection Mounted Controls

SD2, HUM1, LT11, S11, REC11

Heat Wheel

RA Opening

RA Opening HUM1- Humidistat (units with frost protection)Code 24= F

596597 Deck

PanelRAT

84

85

88 89

Ref. Part Part Qty. No. Description Number 596 Support- HUM1 12/16 & Earlier 111078101 1 1/17 & Later 910194091 1 597 Humidistat- HUM1 12/16 & Earlier 067295001 1 1 1/17 & Later 910190890 1 11 This is the duct mounted Humidistat. If a unit has a wall

mounted Humidistat use p/n 067294901.

Page 54: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 54

Section B- DrawThru Filter/Blank SectionNotes

Primary Codes that pertain: 25, 33 (Mid 2012 & Later), 50 (Mid 2012 & Later)Additional Codes that pertain: 06, 19, 20

Code 25 determines the section’s characteristics. If the first digit of Code 25= A, G the Filters are in an angular rack, if the first digit = F the Filters are in a flat rack, or if the first digit = L, S the filters are in a staggered rack. If the second digit = B there are 30% eff. throwaway filters; if C there are 30% eff. throwaway filters with Antimicrobial Intersept; if H there are 85% throwaway filters. If the second digit = D there are 65% eff. filters, if E there are 95% eff. filters, and if G there are 95% eff. filters with Antimicrobial Intersept. If the second digit = Y there is no filter media specified. If Code 25 = BY, EY there is a Blank/Empty section. Code 25= D*, E*, G*, H*, T*, V* OR Code 50 [Mid 2012 & Later]= L, H indicates the presence of an Air Blender.

Code 33 (Mid 2012 & Later) indicates the presence of a Magnehelic/Differential Filter gauge. Even though the gauge may be located in several different places in the unit, the p/n is listed in this section for convenience.

Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the DrawThru Filter/Blank Access Section, contact Daikin Applied with model and serial number information to ensure that the correct liners, insulation and hardware are ordered. For standard Access Door Latching Assemblies, see Section H.

Codes 19 and 20 determine Return Air section characteristics which has an effect on the final assembly panels.

Ref. Part Part Qty. No. Description Number 65 Pressure Control- PC5 065493801 1

Controls PC5

Section Mounted ControlsPC5, LT13, S13, REC13

Ref. Part Part Qty. No. Description Number 84 Light Fixture 055737501 1 85 Bulb- LT13 065492402 1 88 Light Switch- S13 065492201 1 89 Receptacle- REC13 030187000 1

LT13- Filter Section Light/S13- Filter Section Light Switch/REC13- Filter Section ReceptacleCode 49= E, F84 85

88 89

65

Page 55: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 55

Section B- DrawThru Filter/Blank SectionFilters 1

Ref. Part Code Part Qty. No. Description 25= Number Angular Filter Section (Code 25= A*, D*, E*) N/S Filter 30% Pleated, 16 x 25 x 2" MERV 8 *B 111046306 21 30% Pleated, 16 x 25 x 2" w/ Intersept MERV 8 *C 031298002 21 85% Disposable, 16 x 25 x 2” MERV 13 *H 910102150 21 N/S Filter 30% Pleated, 16 x 20 x 2 MERV 8 *B 111046305 7 30% Disposable, 16 x 20 x 2” w/ Intersept MERV 8 *C 111046505 7 85% Disposable, 16 x 20 x 2” MERV 13 *H 910102152 7 N/S Media Filler Piece ALL 011484101 7 N/S Angle Assembly 2 ALL 056077301 28 Flat Filter Section (Code 25= F*, G*, H*) N/S Filter, Cartridge 65% Cartridge, 24 x 24 x 12" MERV 11 *D 065810704 8 95% Cartridge, 24 x 24 x 12" MERV 14 *E 065810702 8 95% Cartridge, 24 x 24 x 12" w/ Intersept MERV 14 *G 066302252 8 85% Disposable, 24 x 24 x 2” MERV 13 *H 910110394 8 Gasket, Cartridge 5/8 x 1/16 x 24” ALL 021768924 8 N/S Filter, Cartridge 65% Cartridge, 12 x 24 x 12" MERV 11 *D 065810703 4 95% Cartridge, 12 x 24 x 12" MERV 14 *E 065810701 4 95% Cartridge, 12 x 24 x 12" w/ Intersept MERV 14 *G 066302253 4 85% Disposable, 12 x 24 x 2” MERV 13 *H 910110399 4 Gasket, Cartridge 5/8 x 1/16 x 12” ALL 021768912 8 N/S Pre Filter, 24 x 24 x 2” ALL 111046101 8 N/S Pre Filter, 12 x 24 x 2” ALL 111046103 8 Staggered Filter Section (Code 25= L*, S*, T*, V*) 65% Cartridge, 24 x 24 x 12” MERV 11 *D 065810704 8 95% Cartridge, 24 x 24 x 12” MERV 14 *E 065810702 8 95% Cartridge, 24 x 24 x 12” w/ Intersept MERV 14 *G 066302252 8 85% Disposable, 24 x 24 x 2” MERV 13 *H 910110394 8 Gasket, Cartridge 5/8 x 1/16 x 12” ALL 021768912 8 N/S Filter, Cartridge 65% Cartridge, 12 x 24 x 12” MERV 11 *D 065810703 4 95% Cartridge, 12 x 24 x 12” MERV 14 *E 065810701 4 95% Cartridge, 12 x 24 x 12” w/ Intersept MERV 14 *G 066302253 4 85% Disposable, 12 x 24 x 2” MERV 13 *H 910110399 4 Gasket, Cartridge 5/8 x 1/16 x 12” ALL 021768912 8 N/S Pre Filter, 24 x 24 x 2” ALL 111046101 8 N/S Pre Filter, 12 x 24 x 2” ALL 111046103 8

Typical Angular Filter Section Shown

Code 25= A*

1 Note that MERV ratings have changed during the production run, so some lower rated filters may no longer be available. Higher MERV filters can be used as a substitute for lower rated filters.

2 Optional. Angle is mounted on leaving air side.

Page 56: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 56

Section B- DrawThru Filter/Blank SectionAir Blender Section Components, &

Magnehelic/Differential Pressure Gauge

Air Blender Section Components (Code 25= D*, E*, G*, H*, T*, V*) OR (Code 50 [Mid 2012 & Later]= L, H)

Ref. Part Code 50= Part Qty. No. Description Number 65 Panel- Access All 059385501 1 68 Air Blender Low CFM L 205139534 2 High CFM H 205139538 2 75 Plate- Econo. Linkage Access All 113047801 2

6875

65

Magnehelic/Differential Pressure Gauge(Code 33= A****, B****, C**** [Mid 2012 & Later])

75

3396 Ref. Part Part No. Description Number 3396 Differential Press. Gauge, 0- 3” WC 098873203

Page 57: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 57

Section C- DrawThru Blank Access SectionOR Separate Inverter Section

Notes

Primary Codes that pertain: 26, 14, 15Additional Codes that pertain: 06

Code 26 determines if a section is installed and if so, the size of the section. If Code 26= E there is a 24” Blank/Empty section; if Code 26= F, S there is a blank 48” section; if Code 26= Y, there is no section.

Codes 14 & 15 determine if the unit has inverter(s) and if so where they are installed. If Code 14= 1, 2, 4 AND Code 26= S, there is a separate Inverter Section. If Code 14= 3, 5, 6, 7, 8, 9, the inverter(s) are installed in the Supply Air Section. If Code 14= Y, there are no inverters. Code 15 identifies the inverter brand supplied. If Code 15= F, the unit is set up for a field supplied Inverter. If Code 15= F, contact Daikin Applied with the Inverter Vendor and vendor part number to see if a replacement can be supplied. All components pertaining to the inverters are listed in the Supply Air Section (Section F).

Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the Blank/Empty Section, contact Daikin Applied to ensure correct liners, insulation and hardware are ordered. For standard Access Door Latching Assemblies, see Section H.

Ref. Part Part Qty. No. Description Number 84 Light Fixture 042229500 1 85 Bulb- LT21 065492402 1 88 Light Switch- S21 065492201 1 89 Receptacle- REC21 030187000 1

LT21- DT Access Section Light/S21- DT Access Section Light Switch/REC21- DT Access Section Receptacle84 85

88 89

Section Mounted ControlsLT21, S21, REC21

Return Air Inverter (AFD20)

Supply Air Inverter (AFD10)

Page 58: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 58

Section D- DrawThru Cooling SectionNotes

Primary Codes that pertain: 03, 27, 28Additional Codes that pertain: 06

Code 03 determines the DX cooling coil size. If Code 03= S there is a small face area coil (24” section), and if Code 03= L it is a large face area coil (48” section).

Code 27 determines if there is a Section D. If Code 27= YYYY, then there is no section (for RPS OR RFS units this indicates that the cooling coil is in the BlowThru position. RDT units always have a section D). If the first three digits of Code 27= DYY then the section contains only a drain pan in a 48” section. If the first three digits of Code 27= GYY then the unit is cooling only with Hot Gas Reheat. If the fourth digit of Code 27= S, the Drain Pan is stainless steel, P, Y in the fourth position indicates that the Drain Pan is galvanized steel. If the fourth digit is L, the Drain Pan is wider than standard and made from stainless steel. If the fourth digit of Code 27= T, then the Drain Pan is wider than standard and made from painted galvanized steel. If the fourth digit of Code 27= L, T, then the first three digits of Code 27 must equal DYY.

Code 28 will apply only if Code 27= CYYY OR CYYS, and determines the DrawThru Coil characteristics.

Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the DrawThru Cooling Section, contact Daikin Applied to ensure correct liners, insulation and hardware are ordered. For standard Access Door Latching Assemblies, see Section H.

NOTE: The drawings and components listed in this section also apply to Section I— BlowThru Cooling Section for RPS OR RFS units.

Page 59: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 59

Small Face Area Coil24” SectionCode 03= S

10

13

43

393

Section D- DrawThru Cooling SectionEvaporator Coils, Drain Pans, Gasketing 1, 2

3

4

43

11

1239

13

39

1037

Ref. Part Part Qty. No. Description Number 3 Coil- Lower 1 4 Coil- Upper 1 10 Drain Pan 2, 3 Galv. C27= CYYY, CYYP 2 056267755 1 Stainless C27= CYYS 2 056267756 1 11 Drain Pan 2, 3 Galv. C27= CYYY, CYYP 2 096235001 1 Stainless C27= CYYS 2 055531354 1 12 Pan- Liner 3 055531202 1 13 Pan- Auxiliary 3 056271401 1 37 Gasket 3 056003501 120’ 39 Gasket 3 049263200 7’ 43 Gasket 3 021911422 4

48” Section, Large Face Coils- Code 03= L— Unit Sizes 050- 075 only

Large Face Area Coil48” SectionCode 03= L

24” Section, Small Face Coils- Code 03= S

Ref. Part Part Qty. No. Description Number 3 Coil 1

10 Drain Pan 2, 3 Galv. C27= CYYY, CYYP 2 056267751 1 Stainless C27= CYYS 2 056267752 1 13 Pan- Auxiliary 2, 3 057356802 1 39 Gasket 3 049263200 6’ 43 Gasket 3 021911422 2

1 Contact Daikin Applied with unit GO and/or serial number so that the correct coil(s) can be identified.2 For Drain Pans and components when Code 27= GYY* AND/OR Code 27= ***L, ***T contact Daikin Applied with model and

serial number information so that the required part(s) can be identified.3 For BlowThru units (Code 35 AND Code 36 CANNOT be all Ys) substitute Code 35 for Code 27. BlowThru and DrawThru

Cooling sections use the SAME parts, just the coding is different.

Page 60: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 60

Section E- Spacer Section (RPS, RFS)Notes

Primary Codes that pertain: 30Additional Codes that pertain: 06

For RPS, RFS units Code 30 is normally YYYYYY. If Code 26= EEEEEE there is a 24” Blank/Empty section; if Code 26= BBBBBB, FFFFFF then there is a 48” Blank/Empty section.

Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the 48” Spacer Section, contact Daikin Applied to ensure correct liners, insulation and hardware are ordered. For standard Access Door Latching Assemblies, see Section H.

Ref. Part Part Qty. No. Description Number 284 Light Fixture 042229500 1 285 Bulb- LT18 065492402 1 288 Light Switch- S18 065492201 1 289 Receptacle- REC18 030187000 1

LT18- Spacer Section Light/S18- Spacer Section Light Switch/REC18- Spacer Section Receptacle284 285

288 289

Section Mounted ControlsLT18, REC18, S18- Section Mounted Light

Primary Codes that pertain: 04, 30Additional Codes that pertain: 06

Code 04 determines what type of heat has been specified. DrawThru Heat units normally are hydronically heated with Steam (Code 04= S) OR Hot Water (Code 04= W). NOTE: There are some DrawThru Electric Heat RDT units. See Section G [BlowThru Heat] for all Electric Heat components.

Code 30 determines the Hydronic Heating Coil and associated characteristics.

Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the DrawThru Heat Section, contact Daikin Applied to ensure correct liners, insulation and hardware are ordered. For standard Access Door Latching Assemblies, see Section H.

Section E- DrawThru Heat Section (RDT)Notes

Page 61: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 61

3

2

Section E- DrawThru Heat SectionRDT Units

Hot Water OR Steam Coil Heat, Mixing Valves and Actuator (VM1)Code 30 first 3 digits = S11, S12, S13, S14, W11, W22

Coil Location Mixing Valve Detail(HW shown)

163

263

Ref. Sch. Part Code Coil Coil Part Qty. No. Sym. Description 30= Type Height Number 2 Steam Coil- Bottom S11*** 5JA0601H 30” 056053021 1 Steam Coil- Bottom S12*** 5JA1201H 30” 056053022 1 Steam Coil- Bottom S13*** 5JA0602C 30” 056053023 1 Steam Coil- Bottom S14*** 5JA1202C 30” 056053024 1 HW Coil- Bottom 7/12 & Earlier W11*** 5WH0901H 30” 056053025 1 HW Coil- Bottom 8/12 & Later W11*** 5WH0901H 30” 404088903 1 HW Coil- Bottom 7/12 & Earlier W22*** 5WS0902C 30” 056053026 1 HW Coil- Bottom 8/12 & Later W22*** 5WS0902C 30” 404088904 1 3 Steam Coil- Top S11*** 5JA0601H 27” 056053031 1 Steam Coil- Top S12*** 5JA1201H 27” 056053032 1 Steam Coil- Top S13*** 5JA0602C 27” 056053013 1 Steam Coil- Top S14*** 5JA1202C 27” 056053014 1 HW Coil- Top 7/12 & Earlier W11*** 5WH0901H 27” 056053035 1 HW Coil- Top 8/12 & Later W11*** 5WH0901H 27” 404088703 1 HW Coil- Top 7/12 & Earlier W22*** 5WS0902C 27” 056053016 1 HW Coil- Top 8/12 & Later W22*** 5WS0902C 27” 404088704 1 N/S Valve, 2 Way Steam w/ Act.2

1.25” S**E2E 5JA All 113147501 1 1.50” S**F2E 5JA All 113147701 1 2.00” S**G2E 5JA All 113147901 1 2.50” S**H2E 5JA All 113148101 1 163 VM1 Actuator- 24V, 1.25”- 2.00” Valve 1 W****E All All 300046566 1 Actuator- 24V, 2.50”- 3.00” Valve 1 W****E All All 113149601 1 263 Valve, 3 Way HW w/ Actuator 1.25” W**E3E 5WH, 5WS All 113166703 1 1.50” W**F3E 5WH, 5WS All 113166704 1 2.00” W**G3E 5WH, 5WS All 113166705 1 2.50” W**H3E 5WH, 5WS All 113166706 1 3.00” W**J3E 5WH, 5WS All 113166707 1 N/S= Not shown on diagram.1 Note that the HW Valve is factory supplied WITH the Actuator. Use this p/n when replacing the HW Actuator ONLY.2 Note that the Steam Valve is factory supplied WITH the Actuator. For Actuator ONLY p/ns contact Daikin Applied with model and

serial number information so that the correct Actuator can be identified.

Page 62: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 62

Section F- Supply Air SectionNotes

Primary Codes that pertain: 31, 32, 59 (Mid 2012 & Later), 08, 14, 15, 40, 49Additional Codes that pertain: 04, 06, 16, 17, 23 (Mid 2012 & Later), Code 33 (Mid 2012 & Later), 34

Code 31 determines the Supply Fan size and type, Code 32 determines the Motor horsepower and type, and Code 33 (Mid 2012 & Earlier) OR Code 59 (Mid 2012 & Later) determine the drive selection. Supply Air Fan Section parts, Fans, and Motors are listed in this section. Drive components (Fan Sheave, Motor Sheave, V-belt(s), and Sheave Bushing(s) [if required]) are NOT listed as they are unique to the unit. If a drive component is required you may use the number from the part and cross reference it in the Daikin Applied Parts catalog, The Daikin Parts E-Commerce site, or contact Daikin Applied with model and serial number information.

Code 08 determines the location of the unit’s Main Control Box. Note that RDT units normally have Main Control Boxes located in the Supply Air Section.

Codes 14 & 15 determine if the unit has inverter(s), and if so where they are installed. If Code 14= Y, there are no inverters. If Code 14= 3, 5, 6, 7, 8, 9, the inverter(s) are installed in the Supply Air Section. If Code 14= 1, 2, 4, there is a separate Inverter Section. Code 15 specifies the inverter brand. If Code 15= F, the unit is set up for a field supplied Inverter. If Code 15= F, contact Daikin Applied with the Inverter Vendor and vendor part number to see if a replacement can be supplied.

Code 40 determines the Discharge Plenum configuration. The Discharge Plenum is located in Section F when the section is bolted directly to the condenser (Section M). RDT units always have the Discharge Plenum located in Section F. If Code 40= BE, there is an Isolation Damper with actuator ACT5. This damper is detailed in Section K.

Code 49 determines if the Supply Air cabinet has a Belt Guard (Code 49= A, D), a Fan Section Light (Code 49= B, E), OR both (Code 49= C, F).

Code 04 and Code 34 determine the heat type, which can affect the final assembly part numbers, the location of the Discharge Plenum, as well as the section installed controls.

Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the Supply Air Section, contact Daikin Applied to ensure correct liners, insulation and hardware are ordered. For standard Access Door Latching Assemblies, see Section H.

Code 16 determines if a Smoke Detector is located in the Supply Air Cabinet. If Code 16= 2, 3, a Smoke Detector (SD1) is present.

Code 17 determines the type of Enthalpy and Miscellaneous Auxiliary Controls included. If Code 17= C*, the unit is equipped with Differential Enthalpy Control. The second digit of Code 17 lists the inclusion of Freezstats, Line Reactors, Phase Failure, and Ground Fault protection.

Code 23 (Mid 2012 & Later) indicates the presence of Plenum/Vestibule Lights, UV lights, misc. inverters, a 115V Service Outlet, and/or Intelligent Equipment.

Code 33 (Mid 2012 & Later) indicates the presence of a Magnehelic/Differential Filter Gauge and/or Ebtron Flow Controls, Refer to Section B (DrawThru Filter Section) for the Gauge part number and description. Note if Ebtron Flow Controls are present (Code 23= ****S, ****G) contact Daikin Applied with model and serial number information so that the correct control can be identified.

Page 63: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 63

Section F- Supply Air SectionForward Curved Fans

Low Pressure- FCLP- Code 31= 27F*, 30F*, 33F*

1

1715

1817

16

5

11

2

3

12

21

22

2023

or

Ref. Part Part Fan Size No. Description Number 27” 30” 33” 1 Motor- see Supply Air Fan Motor Section 2 Housing- Blower Assy 055527713 1 Housing- Blower Assy 055527714 1 Housing- Blower Assy 055527715 1 3 Wheel Assembly 024061101 1 Wheel Assembly 024061103 1 Wheel Assembly 012725735 1 5 Screw Adjust Assy 055528202 1 1 1 11 Shaft 1.688” Dia. 055599602 1 Shaft 1.937” Dia. 055582801 1 Shaft 2.188” Dia. 055582701 1 12 Plate, Cutoff 030030102 1 Plate, Cutoff 030030103 1 Plate, Cutoff 029309800 1 15 Mount Assy- Motor 056104501 1 1 1 16 Angle- Motor Mount 055514201 1 1 1 17 Hold Down 041272900 1 1 Hold Down 041272900 1 18 Angle- Clamping 055576601 1 1 1 20 Plate- Shim 055599701 4 Plate- Shim 055599801 4 Plate- Shim 032422700 2 21 Key- Fan 4.75” Long 023221409 1 Key- Fan 4.75” Long 023221508 1 Key- Fan 4.75” Long 023221508 1 22 Key- Sheave 6.00” Long 023221416 1 Key- Sheave 8.50” Long 023221516 1 Key- Sheave 6.50” Long 023221515 1 23 Bearing- Ball 1.687” 020648652 2 Bearing- Ball 1.937” 020648653 2 Bearing- Ball 2.187” 020648654 2

Page 64: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 64

Section F- Supply Air SectionForward Curved Fans

High Pressure- FCMP- Code 31= 27M*, 30M*, 33M*

1

1715

1817

16

5

11

2

3

12

21

22

2023

or

Ref. Part Part Fan Size No. Description Number 27” 30” 33” 1 Motor- see Supply Air Fan Motor Section 2 Housing- Blower Assy 055527713 1 Housing- Blower Assy 055527714 1 Housing- Blower Assy 055527715 1 3 Wheel Assembly 024061102 1 Wheel Assembly 012727435 1 Wheel Assembly 012727939 1 5 Screw Adjust Assy 055528202 1 1 1 11 Shaft 1.688” Dia. 055599602 1 Shaft 2.176” Dia. 055683402 1 Shaft 2.438” Dia. 055515701 1 12 Plate, Cutoff 030030102 1 Plate, Cutoff 030030103 1 Plate, Cutoff 029309800 1 15 Mount Assy- Motor 056104501 1 1 1 16 Angle- Motor Mount 055514201 1 1 1 17 Hold Down 041272900 1 1 Hold Down 041272900 1 18 Angle- Clamping 055576601 1 1 20 Plate- Shim 055599701 4 Plate- Shim 055683501 2 Plate- Shim 032422700 2 21 Key- Fan 4.75” Long 023221409 1 Key- Fan 4.75” Long 023221508 1 Key- Fan 9.25” Long 023221614 1 22 Key- Sheave 6.00” Long 023221416 1 Key- Sheave 8.50” Long 023221516 1 Key- Sheave 6.50” Long 023221610 1 23 Bearing- Ball 1.687” 020648652 2 Bearing- Ball 2.187” 020648654 2 Bearing- Ball 2.437” 020648655 2

Page 65: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 65

Section F- Supply Air SectionAir Foil Fan- Double Width- RPS Units (Code 31= 27A*, 30A*, 33A*)

Ref. Part Part Fan Size No Description Number 27” 30” 33” 1 Motor- see Supply Air Fan Motor Section 2 Housing Assy. 055527701 1 2A Inlet Funnel Only 031940901 2 2B Cut Off Plate Only 031635800 2 2 Housing Assy. 055527702 1 2A Inlet Funnel Only 031940902 2 2B Cut Off Plate Only 031635900 2 Housing Assy. 055527703 1 2A Inlet Funnel Only 031940903 2 2B Cut Off Plate Only 031636000 2 3 Wheel, Fan- Single Inlet Single Width CW 066543201 1 Wheel, Fan- Single Inlet Single Width CW 066543203 1 Wheel, Fan- Single Inlet Single Width CW 066543205 1 4 Wheel, Fan- Single Inlet Single Width CCW 066543202 1 Wheel, Fan- Single Inlet Single Width CCW 066543204 1 Wheel, Fan- Single Inlet Single Width CCW 066543206 1 5 Screw Adjust Assembly 055528202 2 2 2 11 Shaft- 2.188” Diameter 205982906 1 Shaft- 2.438” Diameter 055582902 1 Shaft- 2.438” Diameter 055515702 1 15 Motor Mount Assembly 056104501 1 1 1 16 Angle- Motor Mount 055514201 1 1 1 17 Holddown 041272900 1 1 2 18 Angle, Clamping 055576601 1 1 21 Key- Fan 9.25” Long X 1/2” Diameter 023221517 1 Key- Fan 9.25” Long X 5/8” Diameter 023221614 1 Key- Fan 4.75” Long X 5/8” Diameter 023221617 2 22 Key- Sheave 6.50” Long X 1/2” Diameter 023221515 1 Key- Sheave 6.50” Long X 5/8” Diameter 023221610 1 1 25 Bearing- Ball 2.187” 020648654 2 Bearing- Ball 2.437” 020648655 2 2

21

42

18

1

17

17

2B

3

2A

16

11

2522

15

5

Page 66: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 66

Section F- Supply Air SectionAir Foil Fan- Single Width- RDT Units

Code 31= 40B1, 40B2, 40B3, 44B1, 44B2, 44B3

Ref. Part Part Fan Size No. Description Number 40” 44” 1 Motor- see Supply Air Fan Motor Section 3 Wheel, Fan- Single Inlet/Single Width 066543243 1 Wheel, Fan- Single Inlet/Single Width 110942010 1 5 Screw Adjust Assembly 055528203 2 2 11 Shaft 2.188” 055615902 1 Shaft 2.438” 055534702 1 15 Mount Assembly-Motor 056104501 1 1 16 Angle -Motor Mount 055514201 1 1 17 Angle, Clamping 055512701 2 2 20 Bearing- Ball 2.187” 020648656 2 Bearing- Ball 2.437” 020648655 2 21 Key- Fan 4.25” Long X 1/2” Diameter 023221519 1 Key- Fan 6.50” Long X 5/8” Diameter 023221610 1 22 Key- Fan 5.50” Long X 1/2” Diameter 023221513 1 Key- Fan 5.50” Long X 5/8” Diameter 023221607 1 24 Tubing- Plastic 021136790 1 Tubing- Plastic 021136795 1 25 Inlet Funnel Assembly 031940905 1 Inlet Funnel Assembly 110941810 1 26 Fitting- 1/8” MPT 027674000 1 1 27 Fitting, Reducer- 1/4” OD X 1/8” FPT 027674100 1 1 28 Fitting 000109800 1 1

243

5

1

11

1622 15

20

25

21

2026

17

2827

Page 67: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 67

Section F- Supply Air SectionFan Mounts- 27” Forward Curved Fan

Code 31= 27F1, 27F2, 27F3, 27M1, 27M2, 27M3

161 162

163 164

188

189

181

121

Ref. Fan Motor Part Part Qty. No. HP Description Number 121 All Mount Spring Code 31= 27*2 251783201 4 Seismic Code 31= 27*3 251783301 4 161 5- 10 Spring Mount- Green 251784701 1 15- 30 Spring Mount- Dark Brown 251784801 1 40, 50 Spring Mount- Red 251784901 1 162 All Spring Mount- Green 251784701 1 163 5 Spring Mount- Green 251784701 1 7.5, 10 Spring Mount- Dark Brown 251784801 1 15- 30 Spring Mount- Red 251784901 1 40, 50 Spring Mount- Tan 251785001 1 164 All Spring Mount- Dark Brown 251784801 1 181 All Nut Spring Code 31= 27*2 059992201 12 Seismic Code 31= 27*3 111056301 20 188 All Nut 040500002 4 189 All Screw Spring Code 31= 27*2 112047201 12 Seismic Code 31= 27*3 112047201 20

Spring Mounts (Code 31= 27F2, 27M2) AND 1

Seismic Spring (Code 31= 27F3, 27M3) 1

Ref. Fan Motor Part Part Qty. No. HP Description Number 21 All Channel- Mount Support 098316001 4 61 3- 10 Rubber Mount- Black 021639704 1 15- 30 Rubber Mount- Red 021639701 1 62 All Rubber Mount- Black 021639704 1 63 3, 5 Rubber Mount- Black 021639704 1 7.5- 30 Rubber Mount- Red 021639701 1 64 3- 7.5, 20- 30 Rubber Mount- Red 021639701 1 10, 15 Rubber Mount- Black 021639704 1 81 All Nut 059992201 8 89 All Screw 112047201 8 91 All Nut- 1/2-13 032333305 12 92 All Screw- Cap, 1/2-13 X 1” 040499501 8 93 All Washer- Plain, 1/2” 048164812 8

Rubber Mounts (Code 31= 27F1, 27M1)

Rubber Mounts

Spring Mounts

Mount Locations61161 or

63163 or

16262 or

16464 or

21

92

91

91

89

81

Seismic strap used only when Code 31= 27*3.

9361 62

63 64

1 Note that some spring colors have changed during production. The preferred spring combinations are shown above.

Page 68: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 68

Section F- Supply Air SectionFan Mounts- 27” Airfoil Double Width Fan

Code 31= 27A1, 27A2, 27A3

Ref. Fan Motor Part Part Qty. No. HP Description Number 21 All Channel- Mount Support 098316001 4 61 3- 10 Rubber Mount- Black 021639704 1 15- 50 Rubber Mount- Red 021639701 1 62 All Rubber Mount- Black 021639704 1 63 3, 5, 10 Rubber Mount- Black 021639704 1 7.5, 15- 50 Rubber Mount- Red 021639701 1 64 3- 7.5, 15- 30 Rubber Mount- Black 021639704 1 10, 40, 50 Rubber Mount- Red 021639701 1 81 All Nut 059992201 8 89 All Screw 112047201 8 91 All Nut- 1/2-13 032333305 12 92 All Screw- Cap, 1/2-13 X 1” 040499501 8 93 All Washer- Plain, 1/2” 048164812 8

Rubber Mounts (Code 31= 27A1)

Mount Locations61

161or

63

163or

16262 or

16464 or

Rubber Mounts

21

92

91

91

89

81

9361 62

63 64

161 162

163 164

188

189

181

121

Spring Mounts

Seismic strap used only when Code 31= 27A3.

Ref. Fan Motor Part Part Qty. No. HP Description Number 121 All Mount Spring Code 31= 27A2 251783201 4 Seismic Code 31= 27A3 251783301 4 161 5- 10 Spring Mount- Green 251784701 1 15- 30 Spring Mount- Dark Brown 251784801 1 40, 50 Spring Mount- Red 251784901 1 162 All Spring Mount- Green 251784701 1 163 5 Spring Mount- Green 251784701 1 7.5, 10 Spring Mount- Dark Brown 251784801 1 15- 30 Spring Mount- Red 251784901 1 40, 50 Spring Mount- Tan 251785001 1 164 All Spring Mount- Dark Brown 251784801 1 181 All Nut Spring Code 31= 27A2 059992201 12 Seismic Code 31= 27A3 111056301 20 188 All Nut 040500002 4 189 All Screw Spring Code 31= 27A2 112047201 12 Seismic Code 31= 27A3 112047201 20 N/S All Shim Code 31= 27A3 910138495 4

Spring Mounts (Code 31= 27A2) AND 1

Seismic Spring (Code 31= 27A3) 1

N/S= Not shown on diagram. 1 Note that some spring colors have changed during production. The preferred spring

combinations are shown above.

Page 69: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 69

Section F- Supply Air SectionFan Mounts- 30” Airfoil Double Width Fan

Code 31= 30A1, 30A2, 30A3

Ref. Fan Motor Part Part Qty. No. HP Description Number 21 All Channel- Mount Support 098316001 4 61 3, 5 Rubber Mount- Black 021639704 1 7.5- 50 Rubber Mount- Red 021639701 1 62 All Rubber Mount- Black 021639704 1 63 3- 30 Rubber Mount- Red 021639701 1 40, 50 Rubber Mount- Green 021639703 1 64 3- 15 Rubber Mount- Black 021639704 1 20- 50 Rubber Mount- Red 021639701 1 81 All Nut 059992201 8 89 All Screw 112047201 8 91 All Nut- 1/2-13 032333305 12 92 All Screw- Cap, 1/2-13 X 1” 040499501 8 93 All Washer- Plain, 1/2” 048164812 8

Rubber Mounts (Code 31= 30A1)

Mount Locations61161 or

63163 or

16262 or

16464 or

161 162

163 164

188

189

181

121

Rubber Mounts

Spring Mounts

21

92

91

91

89

81

Seismic strap used only when Code 31= 30A3.

9361 62

63 64

Ref. Fan Motor Part Part Qty. No. HP Description Number 121 All Mount Spring Code 31= 30A2 251783201 4 Seismic Code 31= 30A3 251783301 4 161 5 Spring Mount- Green 251784701 1 7.5- 20 Spring Mount- Dark Brown 251784801 1 25- 50 Spring Mount- Red 251784901 1 162 All Spring Mount- Green 251784701 1 163 5, 7.5 Spring Mount- Dark Brown 251784801 1 10- 20 Spring Mount- Red 251784901 1 25- 50 Spring Mount- Tan 251785001 1 164 All Spring Mount- Dark Brown 251784801 1 181 All Nut Spring Code 31= 30A2 059992201 12 Seismic Code 31= 30A3 111056301 20 188 All Nut 040500002 4 189 All Screw Spring Code 31= 30A2 112047201 12 Seismic Code 31= 30A3 112047201 20

Spring Mounts (Code 31= 30A2) AND 1

Seismic Spring (Code 31= 30A3) 1

1 Note that some spring colors have changed during production. The preferred spring combinations are shown above.

Page 70: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 70

Section F- Supply Air SectionFan Mounts- 33” Airfoil Double Width Fan

Code 31= 33A1, 33A2, 33A3

Ref. Fan Motor Part Part Qty. No. HP Description Number 21 All Channel- Mount Support 098316001 4 61 3- 10 Rubber Mount- Black 021639704 1 15- 50 Rubber Mount- Red 021639701 1 62 3, 5 Rubber Mount- Red 021639701 1 7.5- 50 Rubber Mount- Black 021639704 1 63 3- 40 Rubber Mount- Red 021639701 1 50 Rubber Mount- Green 021639703 1 64 All Rubber Mount- Red 021639701 1 81 All Nut 059992201 8 89 All Screw 112047201 8 91 All Nut- 1/2-13 032333305 12 92 All Screw- Cap, 1/2-13 X 1” 040499501 8 93 All Washer- Plain, 1/2” 048164812 8

Rubber Mounts (Code 31= 33A1)

Mount Locations61

161or

63

163or

16262 or

16464 or

Rubber Mounts

21

92

91

91

89

81

9361 62

63 64

161 162

163 164

188

189

181

121

Spring Mounts

Seismic strap used only when Code 31= 33A3.

Ref. Fan Motor Part Part Qty. No. HP Description Number 121 All Mount Spring Code 31= 33A2 251783201 4 Seismic Code 31= 33A3 251783301 4 161 5 Spring Mount- Green 251784701 1 7.5- 15 Spring Mount- Dark Brown 251784801 1 20- 40 Spring Mount- Red 251784901 1 50 Spring Mount- Tan 251785001 1 162 All Spring Mount- Green 251784701 1 163 5, 7.5 Spring Mount- Dark Brown 251784801 1 10- 20 Spring Mount- Red 251784901 1 25- 50 Spring Mount- Tan 251785001 1 164 All Spring Mount- Dark Brown 251784801 1 181 All Nut Spring Code 31= 33A2 059992201 12 Seismic Code 31= 33A3 111056301 20 188 All Nut 040500002 4 189 All Screw Spring Code 31= 33A2 112047201 12 Seismic Code 31= 33A3 112047201 20

Spring Mounts (Code 31= 33A2) AND 1

Seismic Spring (Code 31= 33A3) 1

1 Note that some spring colors have changed during production. The preferred spring combinations are shown above.

Page 71: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 71

Section F- Supply Air SectionFan Mounts- 40” AFSW- RDT Units

Code 31= 40B1, 40B2, 40B3

Ref. Fan Motor Part Part Qty. No. HP Description Number 121 All Mount Spring Code 31= 40B2 251783201 4 Seismic Code 31= 40B3 251783301 4 161 3- 20 Spring Mount- Green 251784701 1 25- 50 Spring Mount- Dark Brown 251784801 1 162 3- 10, 25, 40, 50 Spring Mount- Yellow 251784601 1 15- 20, 30 Spring Mount- Dark Brown 251784801 1 163 3- 7.5 Spring Mount- Green 251784701 1 10- 20 Spring Mount- Dark Brown 251784801 1 25- 50 Spring Mount- Red 251784901 1 164 3- 25 Spring Mount- Green 251784701 1 25 Spring Mount- Red 251784901 1 40, 50 Spring Mount- Dark Brown 251784801 1 181 All Nut Spring Code 31= 40B2 059992201 12 Seismic Code 31= 40B3 111056301 20 188 All Nut 040500002 4 189 All Screw Spring Code 31= 40B2 112047201 12 Seismic Code 31= 40B3 112047201 20

Spring Mounts (Code 31= 40B2) AND 1

Seismic Spring (Code 31= 40B3) 1

Ref. Fan Motor Part Part Qty. No. HP Description Number 21 All Channel- Mount Support 098316001 4 61 3- 30 Rubber Mount- Black 021639704 1 40 Rubber Mount- Red 021639701 1 62 All Rubber Mount- Black 021639704 1 63 3- 10 Rubber Mount- Black 021639704 1 15- 40 Rubber Mount- Red 021639701 1 64 All Rubber Mount- Black 021639704 1 81 All Nut 059992201 8 89 All Screw 112047201 8 91 All Nut- 1/2-13 032333305 12 92 All Screw- Cap, 1/2-13 X 1” 040499501 8 93 All Washer- Plain, 1/2” 048164812 8

Rubber Mounts (Code 31= 40B1)

Mount Locations

61161 or

63163 or

16262 or

16464 or

161 162

163 164

188

189

181

121

Rubber Mounts

Spring Mounts

21

92

91

91

89

81

Seismic strap used only when Code 31= 40B3.

9361 62

63 64

1 Note that some spring colors have changed during production. The preferred spring combinations are shown above.

Page 72: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 72

Section F- Supply Air SectionFan Mounts- 44” AFSW- RDT Units

Code 31= 44B1, 44B2, 44B3

Ref. Fan Motor Part Part Qty. No. HP Description Number 121 All Mount Spring Code 31= 44B2 251783201 4 Seismic Code 31= 44B3 251783301 4 161 3- 20 Spring Mount- Green 251784701 1 25- 50 Spring Mount- Dark Brown 251784801 1 162 All Spring Mount- Dark Brown 251784801 1 163 3- 7.5 Spring Mount- Green 251784701 1 10- 25 Spring Mount- Dark Brown 251784801 1 30- 50 Spring Mount- Red 251784901 1 164 All Spring Mount- Red 251784901 1 181 All Nut Spring Code 31= 44B2 059992201 12 Seismic Code 31= 44B3 111056301 20 188 All Nut 040500002 4 189 All Screw Spring Code 31= 44B2 112047201 12 Seismic Code 31= 44B3 112047201 20

Spring Mounts (Code 31= 44B2) AND 1

Seismic Spring (Code 31= 44B3) 1

Ref. Fan Motor Part Part Qty. No. HP Description Number 21 All Channel- Mount Support 098316001 4 61 3- 25 Rubber Mount- Black 021639704 1 30- 50 Rubber Mount- Red 021639701 1 62 All Rubber Mount- Red 021639701 1 63 3- 10 Rubber Mount- Black 021639704 1 15- 50 Rubber Mount- Red 021639701 1 64 All Rubber Mount- Red 021639701 1 81 All Nut 059992201 8 89 All Screw 112047201 8 91 All Nut- 1/2-13 032333305 12 92 All Screw- Cap, 1/2-13 X 1” 040499501 8 93 All Washer- Plain, 1/2” 048164812 8

Rubber Mounts (Code 31= 44B1)

Mount Locations

61161 or

63163 or

16262 or

16464 or

161 162

163 164

188

189

181

121

Rubber Mounts

Spring Mounts

21

92

91

91

89

81

Seismic strap used only when Code 31= 44B3.

9361 62

63 64

1 Note that some spring colors have changed during production. The preferred spring combinations are shown above.

Page 73: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 73

H.P. Motor H.P. Unit ODP HiEff ODP PrEff. TEFC HiEff TEFC PrEff Code 32= Voltage C32= *EY C32= *JY C32= *HY C32= *KY C09= 12 3 H*Y 208/60/3 039447500 065817100 047358100 065819400 5 J*Y 208/60/3 039447600 065817200 049186800 065819500 7.5 K*Y 208/60/3 037530300 065817300 047665900 065819600 10 L*Y 208/60/3 038999000 065817400 047666100 065819700 15 M*Y 208/60/3 039896200 065817500 049186900 065819800 20 N*Y 208/60/3 039895800 065817600 049187000 065819900 25 P*Y 208/60/3 039448900 065817700 049187100 065820000 30 Q*Y 208/60/3 041775200 205066500 049187200 205066800 40 R*Y 208/60/3 041775300 205067100 049187300 205070700 50 S*Y 208/60/3 041775400 205067500 049187400 205091600 C09= 29 3 H*Y 230/60/3 039442400 065818100 049262300 065820100 5 J*Y 230/60/3 039442500 065818200 040161200 065820200 7.5 K*Y 230/60/3 039448700 065818300 049100500 065820300 10 L*Y 230/60/3 039446500 065818400 044691100 065820400 15 M*Y 230/60/3 039446600 065818500 038689700 065820500 20 N*Y 230/60/3 039448800 065818600 040161300 065820600 25 P*Y 230/60/3 039896100 065818700 040161400 065820700 30 Q*Y 230/60/3 040626800 205066600 049025300 205066900 40 R*Y 230/60/3 041770000 205067200 048448000 205069200 50 S*Y 230/60/3 039899200 205067600 040161600 205069400 C09= 27 3 H*Y 460/60/3 039442400 065818100 049262300 065820100 5 J*Y 460/60/3 039442500 065818200 040161200 065820200 7.5 K*Y 460/60/3 039448700 065818300 049100500 065820300 10 L*Y 460/60/3 039446500 065818400 044691100 065820400 15 M*Y 460/60/3 039446600 065818500 038689700 065820500 20 N*Y 460/60/3 039448800 065818600 040161300 065820600 25 P*Y 460/60/3 039896100 065818700 040161400 065820700 30 Q*Y 460/60/3 040626800 205066600 049025300 205066900 40 R*Y 460/60/3 041770000 205067200 048448000 205069200 50 S*Y 460/60/3 039899200 205067600 040161600 205069400 C09= 37 3 H*Y 575/60/3 046741600 046511700 049188300 046514500 5 J*Y 575/60/3 046741900 205168900 049188400 046514600 7.5 K*Y 575/60/3 047443300 205168800 049188500 046514700 10 L*Y 575/60/3 047443400 205168600 049188600 065821400 15 M*Y 575/60/3 047443500 205166600 049185200 065821500 20 N*Y 575/60/3 049181100 205166800 049188700 065821600 25 P*Y 575/60/3 049181200 205166900 049188800 065821700 30 Q*Y 575/60/3 049181300 205066700 049188900 205067000 40 R*Y 575/60/3 049181400 205067300 049189000 205069300 50 S*Y 575/60/3 049181500 205091800 049189100 205069500

Section F- Supply Air SectionSupply Air Fan Motors

Standard Motors: Code 32= **Y

Page 74: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 74

Section F- Supply Air SectionSupply Air Fan Motors, Continued

Shaft Grounded Motors: Code 32= **S

H.P. Motor HP Unit ODP PrEff. TEFC PrEff C32= **S Voltage C32= *JS C32= *KS C09= 12 3 H*S 208/60/3 300052109 065819499 5 J*S 208/60/3 300052118 065819599 7.5 K*S 208/60/3 065817399 065819699 10 L*S 208/60/3 065817499 065819799 15 M*S 208/60/3 065817599 065819899 20 N*S 208/60/3 065817699 065819999 25 P*S 208/60/3 065817799 065820099 30 Q*S 208/60/3 205066599 205066899 40 R*S 208/60/3 205067199 205070799 50 S*S 208/60/3 205067599 205091699 C09= 29 3 H*S 230/60/3 300049698 300049688 5 J*S 230/60/3 300049699 300049689 7.5 K*S 230/60/3 300049700 300049690 10 L*S 230/60/3 300049701 065820499 15 M*S 230/60/3 065818599 300049198 20 N*S 230/60/3 065818699 300049691 25 P*S 230/60/3 300049702 300049692 30 Q*S 230/60/3 300049703 205066999 40 R*S 230/60/3 300049704 300049693 50 S*S 230/60/3 300049705 300049694 C09= 27 3 H*S 460/60/3 300049698 300049688 5 J*S 460/60/3 300049699 300049689 7.5 K*S 460/60/3 300049700 300049690 10 L*S 460/60/3 300049701 065820499 15 M*S 460/60/3 065818599 300049198 20 N*S 460/60/3 065818699 300049691 25 P*S 460/60/3 300049702 300049692 30 Q*S 460/60/3 300049703 205066999 40 R*S 460/60/3 300049704 300049693 50 S*S 460/60/3 300049705 300049694 C09= 37 3 H*S 575/60/3 046511799 205168499 5 J*S 575/60/3 205168999 046514699 7.5 K*S 575/60/3 205168899 046514799 10 L*S 575/60/3 205168699 065821499 15 M*S 575/60/3 205166699 065821599 20 N*S 575/60/3 205166899 065821699 25 P*S 575/60/3 205166999 065821799 30 Q*S 575/60/3 098865399 205067099 30 Q*S 575/60/3 098865399 205067099 40 R*S 575/60/3 205067399 205069399 50 S*S 575/60/3 205091899 205069599

Page 75: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 75

Section F- Supply Air SectionBelt Guards

Code 49= A, C, D, F

Ref. Part Part Fan Size No. Description Number 27” 30” 33” 40 Grille Assembly 055606001 1 Grille Assembly 055606002 1 Grille Assembly 055606003 1 41 Belt Guard Assembly 055606011 1 Belt Guard Assembly 055606012 1 Belt Guard Assembly 055606013 1

Air Foil Double Width (AFDW) OR Forward Curved Fans (FCLP, FCMP)

41

40

Air Foil Single Width (AFSW) with Side Discharge (Code 40= H),

Main Control Box (Code 08= S, F)

81

80

Air Foil Single Width (AFSW) with Side Discharge (Code 40= S),

No Control Box (Code 08= P, D)

81

80

82

Air Foil Single Width (AFSW) with Bottom Discharge (Code 40= G),Main Control Box (Code 08= S, F)

81

80

The Main Control Box is mounted in this section on RDT units.

83

Air Foil Single Width (AFSW) with Bottom Discharge (Code 40= B),

No Control Box (Code 08= P, D, Y)

81

80

Ref. Part Part Fan Size No. Description Number 40” 44” 80 Grille Assy 056259201 1 1 81 Grille Assy 056259202 1 1 82 Grille Assy 056259203 1 1 83 Grille Assy 056259204 1 1

RPS units (Main Control Box is mounted in the Discharge Plenum Section K).

82

RPS units (Main Control Box is mounted in the Discharge Plenum Section K).

The Main Control Box is mounted in this section on RDT units.

83

Page 76: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 76

50

4070

71

72

Supply Air OR Return Air Fan Inverter w/ Bypass Control Box.

(Code 14= 3, 5, 8)Two boxes installed if Code 14= 5

Bypass Controls Detail

Section F- Supply Air SectionInverters & Inverter Bypass Control Box: (03/2013 & Earlier)Motor HP 2- 5 (Code 22= G**, H** , J**; OR Code 32= H**, J**)

MMP30 (Supply)MMP40 (Return)

LR10 (Supply)LR20 (Return)

M30B/M30I (Supply)M40B/M40I (Return)

MMP & Contactor Link Detail

40 40

Supply Air and Return Air Fan

Inverter without Bypass.

(Code 14= 7)

Supply Air OR Return Air Fan

Inverter without Bypass.

(Code 14= 6, 7, 9)

208V

230V

460V

575V

20

8V

230V

460V

575V

20

8V

230V

460V

575V

74

73

72

70

Motor Horsepower 2 3 5

Ref. Sch. Part Part No. Sym. Description Number 40 AFD10, 20 Inverter- see Inverter section 50 Gasket 055940207 1 1 1 1 1 1 1 1 1 1 1 1 70 MMP30, 40 Motor Control 349934047 1 349934048 1 1 349934049 1 1 1 349934050 1 1 1 349934051 1 349934052 1 1 71 LR10, 20 Line Reactor- see page following inverters 72 M30B,I Contactor 349933121 1 1 1 1 1 1 1 1 M40B,I 349933122 1 1 349933123 1 1 73 Contact- Auxiliary 349933821 1 1 1 1 1 1 1 1 1 1 1 1 74 Link 349932922 1 1 1 1 1 1 1 1 1 1 1 1

Page 77: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 77

Section F- Supply Air SectionInverters & Inverter Bypass Control Box: (04/2013 & Later)Motor HP 2- 5 (Code 22= G**, H** , J**; OR Code 32= H**, J**)

208V

230V

460V

575V

20

8V

230V

460V

575V

20

8V

230V

460V

575V

MMP

70

Link 70C

Contactor

72

Front Mtd.Aux. Contact

70B

MMP30/40 & M30/40 Link Detail2 HP Motor- All Voltages3, 5 HP Motors- 460/575V

MMP30/40 & M30/40 Link Detail3, 5 HP Motors- 208/230V

MMP

70B

Contactor72

7070APhase Barrier

Spacer72A

70APhase Barrier

Front Mtd.Aux. Contact

Link 70C

Motor Horsepower 2 3 5

Ref. Sch. Part Part No. Sym. Description Number 40 VFD10, 20 Inverter- see Inverter section

50 Gasket 055940207 1 1 1 1 1 1 1 1 1 1 1 1

70 MMP30, 40 Motor Protector 193542907 1 193542908 1 193542910 1 1 193542911 1 193542912 1 1 1 193543007 1 1 193543009 1 1 70A Phase Barrier 193545501 1 1 1 1 1 1 1 1 1 1 1 1 70B Aux. Contact 193543801 1 1 1 1 1 1 1 1 1 1 1 70C Link 193545901 1 1 1 1 193546001 1 1 1 1 71 LR10, 20 Line Reactor- see page after Inverters

72 M30B, I Contactor 193592105 1 1 M40B, I 193592106 1 193539105 1 1 1 1 1 1 193539106 1 1 193539304 1 72A Spacer 193545801 2 2 2 2

50

40

Supply Air OR Return Air Fan Inverter w/ Bypass Control Box shown.

(Code 14= 3, 5, 8)Two boxes installed if Code 14= 5

MMP30 (Supply)MMP40 (Return)

7071

72

Bypass Controls Detail

LR10 (Supply)LR20 (Return)

M30B/M30I (Supply)M40B/M40I (Return)

40 40

Supply Air and Return Air Fan

Inverter without Bypass.

(Code 14= 7)

Supply Air OR Return Air Fan

Inverter without Bypass.

(Code 14= 6, 7, 9)

Page 78: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 78

50

40

70

71

72Supply Air OR Return Air Fan

Inverter w/Bypass Control Box.(Code 14= 3, 5, 8)

Two boxes installed if C14= 5Bypass Controls Detail

Section F- Supply Air SectionInverters & Inverter Bypass Control Box: (03/2013 & Earlier)

Motor HP 7.5- 25 (Code 22 OR Code 32= K**, L**, M**, N**, P**)Diagrams

MMP30 (Supply)MMP40 (Return)

LR10 (Supply)LR20 (Return)

M30B/M30I (Supply)M40B/M40I (Return)

MMP & Contactor Link DetailMMP p/n 349934147, 48, 49

MMP & Contactor Link DetailMMP p/n 3499340xx

MMP & Contactor Link DetailMMP p/n 349938606

40

Supply Air and Return Air Fan Inverter with-

out Bypass.(Code 14= 7)

72

7073

40

Supply Air OR Return Air Fan

Inverter without Bypass.

(Code 14= 6, 7, 9)

72

72

70

77

76

74

73

72

70

Page 79: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 79

208V

230V

460V

575V

20

8V

230V

460V

575V

20

8V

230V

460V

575V

20

8V

230V

460V

575V

20

8V

230V

460V

575V

Section F- Supply Air SectionInverters & Inverter Bypass Control Box: (03/2013 & Earlier)

Motor HP 7.5- 25 (Code 22 OR Code 32= K**, L**, M**, N**, P**)Components

Motor Horsepower 7.5 10 15 20 25

Ref. Sch. Part Part No. Sym. Description Number 40 AFD10, 20 Inverter- see page after Inverters

50 Gasket 055940207 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

70 MMP30, 40 Motor Control 349934050 1 349934051 1 1 349934052 1 1 349934053 1 1 1 349934054 1 1 349934055 1 1 349934147 1 1 349934148 1 1 349934149 1 1 1 349938606 1 71 LR10, 20 Line Reactor- see page after Inverters

72 M30B,I Contactor 349933121 1 M40B,I 349933122 1 1 349933123 1 1 349933321 1 1 1 1 349933322 1 1 1 349933521 1 1 349933522 1 1 349933523 1 1 349933621 1 1

73 Contact- Auxiliary 349933821 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

74 Link 349932922 1 1 1 1 1 1 1 1 1 1 1 1 1

76 Interlock- Trip 349938701 1

77 Lug Kit (3 per kit) 349938801 2

Page 80: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 80

50

40

Supply Air OR Return Air Fan Inverter w/Bypass Control

Box.(Code 14= 5, 8)

Two boxes installed if C14= 5

Section F- Supply Air SectionInverters & Inverter Bypass Control Box: (04/2013 & Later)

Motor HP 7.5- 25 (Code 22 OR Code 32= K**, L**, M**, N**, P**)Diagrams

40

Supply Air and Return Air Fan

Inverter without Bypass.

(Code 14= 7)

40

Supply Air OR Return Air Fan

Inverter without Bypass.

(Code 14= 7, 9)

70

71

72

Bypass Controls Detail

MMP40 (Return)

LR10 (Supply)

M30B/M30I (Supply)

LR20 (Return)

71

MMP30 (Supply)

70

72M40B/M40I (Return)

MMP30/40 & M30/40 Link Detail7.5 HP Motors- 208/230/460V

10, 15 HP Motors- 460V

MMP

70B

Contactor72

70

Spacer72A

70APhase Barrier

Front Mtd.Aux. Contact

Link 70C

MMP

70

Link 70C

Contactor

72

Front Mtd.Aux. Contact

70B

MMP30/40 & M30/40 Link Detail7.5 HP Motors- 575V

70APhase Barrier

MMP30/40 & M30/40 Link Detail10, 15 HP Motors- 208/230V

15, 20 HP Motors- 575V 20 HP Motors- 460V

25 HP Motors- 460/575V

MMP30/40 & M30/40 Link Detail20, 25 HP Motors- 208/230V

MMP

70

Link 70C

Contactor

72

Front Mtd.Aux. Contact

70B

MMP

70

Link 70C

Contactor

72

Front Mtd.Aux. Contact

70B70APhase Barrier

Page 81: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 81

Section F- Supply Air SectionInverters & Inverter Bypass Control Box: (04/2013 & Later)

Motor HP 7.5- 25 (Code 22 OR Code 32= K**, L**, M**, N**, P**)Components

208V

230V

460V

575V

20

8V

230V

460V

575V

20

8V

230V

460V

575V

20

8V

230V

460V

575V

20

8V

230V

460V

575V

Motor Horsepower 7.5 10 15 20 25

Ref. Sch. Part Part No. Sym. Description Number 40 AFD10, 20 Inverter- see Inverter section

50 Gasket 055940207 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

70 MMP30 ,40 Motor Protector 193542913 1 193543008 1 1 193543009 1 193543010 1 193543011 1 193543012 1 193543301 1 193543303 1 193543304 1 1 1 1 1 193543305 1 193543306 1 193543403 1 1 1 193543404 1

70A Phase Barrier 193545501 1 1 1 1 1 1 1 193547301 1 1 1 1

70B Contact- Auxiliary 193543801 1 1 1 1 1 1 1 193546201 1 1 1 1 1 1 1 1 1 1 1 1 1

70C Link 193545901 1 193546001 1 1 1 1 1 1 193547401 1 1 1 1 1 1 1 1 1 193547501 1 1 1 1 71 LR10, 20 Line Reactor- see page after Inverters 72 M30B, I M40B, I Contactor 9A 193539106 1 12A 193592105 1 1 16A 193592106 1 25A 193539304 1 1 1 1 1 32A 193539501 1 1 1 1 1 50A 193539502 1 1 65A 193539601 1 1 80A 193539602 1 1

72A Spacer 193545801 2 2 2 2 2 2

Page 82: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 82

50

40

70

71

72

Supply Air OR Return Air Fan Inverter w/ Bypass Control Box.

(Code 14= 3, 5, 8)Two boxes installed if Code 14= 5

Bypass Controls Detail

Section F- Supply Air SectionInverters & Inverter Bypass Control Box: (03/2013 & Earlier)Motor HP 30- 50 (Code 22= Q** OR Code 32= Q**, R**, S**)

Diagrams

MMP30 (Supply)MMP40 (Return)

LR10 (Supply)LR20 (Return)

M30B/M30I (Supply)M40B/M40I (Return)

MMP & Contactor Link DetailMMP p/n 349934147, 48, 49

MMP & Contactor Link DetailMMP p/n 349934055

MMP & Contactor Link DetailMMP p/n 349938606

72

7073

72

72

70

77

76

MMP & Contactor Link DetailMMP p/n 349938607

72

7077

76

74

73

72

70

Page 83: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 83

Section F- Supply Air SectionInverters & Inverter Bypass Control Box: (03/2013 & Earlier)Motor HP 30- 50 (Code 22= Q** OR Code 32= Q**, R**, S**)

Components

208V

230V

460V

575V

208

V

230V

460V

575V

208

V

230V

460V

575V

1 Also requires 3 ring terminals.

Motor Horsepower 30 40 50 Ref. Sch. Part Part No. Sym. Description Number 40 AFD10, 20 Inverter- see Inverter section

50 Gasket 055940207 1 1 1 1 1 1 1 1 1 1

70 MMP30 Motor Control 349934055 1 MMP40 349934147 1 349934148 1 349934149 1 1 1 349938606 1 1 349938607 1 1

71 LR10, 20 Line Reactor- see page after Inverters

72 M30B,I Contactor 349933322 1 M40B,I 349933521 1 349933522 1 1 349933523 1 1 349933621 1 349933721 1 1 349933722 1

73 Contact- Auxiliary 349933821 1 1 1 1 1 1 74 Link 349932922 1

76 Interlock- Trip 349938701 1 1 1 1

77 Lug Kit (3 per kit) 349938801 2 2 11 11

Page 84: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 84

Section F- Supply Air SectionInverters & Inverter Bypass Control Box: (04/2013 & Later)Motor HP 30- 50 (Code 22= Q** OR Code 32= Q**, R**, S**)

Diagrams

50

40

Supply Air OR Return Air Fan Inverter w/Bypass Control Box.

(Code 14= 5, 8)Two boxes installed if Code14= 5

40

Supply Air and Return Air Fan

Inverter without Bypass.

(Code 14= 7)

40

Supply Air OR Return Air Fan

Inverter without Bypass.

(Code 14= 7, 9)

70

71

72

Bypass Controls Detail

MMP40 (Return)

LR10 (Supply)

M30B/M30I (Supply)

LR20 (Return)

71

MMP30 (Supply)

70

72M40B/M40I (Return)

MMP30/40 & M30/40 Link Detail30 HP Motors- 460/575V

40 HP Motors- 575V

MMP30/40 & M30/40 Link Detail30 HP Motors- 208/230V

40 HP Motors- 460V50 HP Motors- 460/575V

MMP

70

Link 70C

Contactor

72

Front Mtd.Aux. Contact

70B

MMP

70

Link 70C

Contactor

72

Front Mtd.Aux. Contact

70B

70APhase Barrier

79

78

Contactors

Overload

Interlock

MMP30/40 & M30/40 Link Detail40, 50 HP Motors- 208/230V

72

Page 85: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 85

Section F- Supply Air SectionInverters & Inverter Bypass Control Box: (04/2013 & Later)Motor HP 30- 50 (Code 22= Q** OR Code 32= Q**, R**, S**)

Components

208V

230V

460V

575V

20

8V

230V

460V

575V

20

8V

230V

460V

575V

Motor Horsepower 30 40 50

Ref. Sch. Part Part No. Sym. Description Number 40 AFD10, 20 Inverter- see next page

50 Gasket 055940207 1 1 1 1 1 1 1 1 1 1 1 1

70 MMP30 Motor Protector MMP40 70- 90A 193543405 1 1 45- 63A 193543403 1 36- 50A 193543402 1 1 28- 40A 193543305 1 1 22- 32A 193543304 1

70A Phase Barrier 193547301 1 1 1 1 1

70B Contact- Auxiliary 193546201 1 1 1 1 1 1 1 1

70C Link 193547501 1 1 1 1 1 193547401 1 1 1

71 LR10, 20 Line Reactor- see page after Inverters

72 M30B,I Contactor 150A 193591802 2 2 M40B,I 115A 193591801 2 2 95A 193539603 1 80A 193539602 1 65A 193539601 1 1 1 50A 193539502 1 40A 193539501 1 1

78 OL30 Overload 50- 200A 193549702 1 1 1 OL40 80- 100A 193548608 1

79 Mechanical Interlink 193582601 1 1 1 1

N/S CB30, 40 Circuit Breaker 150A 193550302 1 1 1 1 N/S= Not Shown on Diagram.

Page 86: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 86

Section F- Supply Air SectionInverters

Motor Horsepower 2 3 5 7.5 10 15 20 25 30 40 50

Part Number 098861454 1 098861455 1 098861456 1 098861457 1 098861458 1 098861459 1 098861460 1 098861461 1 098861462 1 098861467 1 1 098861468 1 098861469 1 098861470 1

208/

230V

460V

208/

230V

460V

208

/230

V

460V

208

/230

V

460V

208

/230

V

460V

208

/230

V

460V

208

/230

V

460V

208

/230

V

460V

208

/230

V

460V

208

/230

V

460V

208

/230

V

460V

Code 15= R

Page 87: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 87

Motor Horsepower 2, 3 5 7.5 10 15 20 25 30 40 50

Part Number 112046001 1 112046002 1 112046003 1 112046004 1 112046005 1 112046006 1 112046007 1 112046008 1 112046009 1 112046010 1 112046014 1 112046015 1 112046016 1 112046017 1 112046018 1 112046019 1 112046020 1 112046021 1 112046022 1 112046023 1 112046026 1 112046027 1 112046028 1 112046029 1 112046030 1 112046031 1 112046032 1 112046033 1 112046034 1 112046035 1

208/

230V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

Section F- Supply Air SectionInverters, Continued

1 The replacement VFD Keypad Display is p/n 300040924.

Code 15= A AND/OR Code 23 (Mid 2012 & Later)= **A** 1

Page 88: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 88

Section F- Supply Air SectionInverters, Continued

Motor Horsepower 2 3 5 7.5 10 15 20 25

Part Number 098656901 1 098656902 1 098656903 1 098656904 1 098656905 1 098656906 1 098656907 1 098656908 1 098656914 1 098656915 1 098656916 1 098656917 1 098656918 1 098656919 1 098656920 1 098656921 1 098656924 1 098656925 1 098656926 1 098656927 1 098656928 1 098656929 1 098656930 1 098656931 1 098656943 1 1 1 098656944 1 098656945 1 098656946 1 098656947 1 098656948 1

208V

230V

460V

575V

20

8V

230V

460V

575V

20

8V

230V

460V

575V

20

8V

230V

460V

575V

20

8V

230V

460V

575V

20

8V

230V

460V

575V

20

8V

230V

460V

575V

208V

230V

460V

575V

Code 15= G

Motor Horsepower 30 40 50 Part Number 098656909 1 098656910 1 098656911 1 098656922 1 098656923 1 098656940 1 098656932 1 098656933 1 098656953 1 098656951 1

208V

230V

460V

575V

20

8V

230V

460V

575V

20

8V

230V

460V

575V

Page 89: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 89

Section F- Supply Air SectionInverters, Continued

Motor Horsepower 2 3 5 7.5 10 15 20 25 30 40 50

Part Number 193475806 1 1 193475807 1 1 193475809 1 1 193475810 1 1 193475811 1 1 193475812 1 1 193475813 1 1 193475814 1 1 193475815 1 1 193475816 1 1 349956617 3 1 193475822 1 1 193475823 1 1 193475825 1 1 193475826 1 1 193475827 1 1 193475828 1 1 193475829 1 1 193475830 1 1 193475831 1 1 193475832 1 1 193475883 1 1 193456302 2,4 1 193456303 2,4 1 193456304 2,4 1 193456305 2,4 1 193456306 2,4 1 193456307 2,4 1 193456308 2,4 1 349956647 3 1 349956648 3 1 349956649 3 1 349956650 3 1

208/

230V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

1 Early production units (late 2010 & earlier) shipped with ATV21 VFDs. All ATV21 drives have been replaced with ATV212 drives as listed above. These new drives are drop in replacements with the exception of the Remote Keypad and Communication Cards. The ATV21 Remote Keypad is p/n 349958801. The ATV21 Lonworks communication card is p/n 349927103. The ATV212 Remote Keypad is p/n 349958805 and the Remote Keypad Mounting kit is p/n 349958803. The ATV212 Lonworks communication card is p/n 193482601. All other ATV212 communication cards are integral to the VFD and are not available separately. Note that since the original ATV21 drives are obsolete and unavailable, when at zero stock, repair parts are also not available. If an obsolete ATV21 part fails, the entire drive must be replaced.

2 MD3 Remote Keypad p/n is 349958802.3 MD6 Remote Keypad p/n is 349958805 plus Mount p/n 349958803.4 For 575V units with an MD3 Inverter and Motor under 25 HP a Line Reactor will be installed regardless of whether one is specified in Code

17 (see nomenclature page). See one page after next for Line Reactor part numbers.

Code 15= S, Q AND/OR Code 23 (Mid 2012 & Later)= **Q**

Page 90: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 90

Section F- Supply Air SectionInverters, Continued

Motor Horsepower 2 3 5 7.5 10 15 20 25 30 40 50

Part Number 193552245 1 193552295 1 193552326 1 1 193552246 1 193552296 1 193552215 1 193552202 1 193552327 1 193552216 1 193552203 1 193552328 1 193552217 1 193552204 1 193552329 1 193552218 1 193552205 1 193552330 1 193552319 1 193552206 1 193552331 1 193552320 1 193552207 1 193552332 1 193552321 1 193552208 1 193552333 1 193552322 1 193552309 1 193552334 1 193552323 1 193552310 1 193552335 11 The replacement VFD Keypad Display is p/n 300040924.

208/

230V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208/

230V

460V

575V

Code 15= B OR Code 23 (Mid 2012 & Later)= **B** 1

Page 91: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 91

Section F- Supply Air SectionLine Reactors 1

Motor Horsepower 2 3 5 7.5 10 15 20 25 30 40 50 Part Number 073323502 1 073323503 1 073323504 1 073323505 1 073323506 1 073323507 1 073323508 1 073323509 1 073323511 1 073323512 1 073323517 1 073323518 1 073323519 1 073323520 1 073323521 1 073323522 1 073323523 1 073323533 1 073323534 1 073323535 1 073323541 1 3499649262 1 3499649272 1 3499649292 1 3499649302 1 3499649312 1 3499649322 1 3499649532 1 1 3499649542 1 3499649552 1 3499649562 1

208V

/230

V

460V

575V

208V

/230

V

460V

575V

208V

/230

V

460V

575V

208V

/230

V

460V

575V

208V

/230

V

460V

575V

208V

/230

V

460V

575V

208V

/230

V

460V

575V

208V

/230

V

460V

575V

208V

/230

V

460V

575V

208V

/230

V

460V

575V

208V

/230

V

460V

575V

1 Line Reactors are used when Code 17= CL, CE, CH, CJ, CK, C4, C6, C7, C8, YL, YE, YH, YJ, YK, Y4, Y6, Y7,, Y8; except for MD3 575V Inverters (Code 15= S, Q ) 2- 20 HP. These will always have a Line Reactor installed regardless of Code 17.

2 These are 5% impedance Line Reactors. Some units may have 3% impedance Line Reactors, the 5% may be used in their place. Due to dimensional differences, minor field modifications may be required for proper installation.

Page 92: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 92

Section F- Supply Air SectionSection Mounted Controls

PC7, HL22, LT10, S10, REC10, UV Lights

67 Ref. Part Part Qty. No. Description Number 67 T-stat- HL22 Hi Limit 047938801 1

HL22- Gas Heat Hi Limit SwitchCode 04= A

Ref. Part Part Qty. No. Description Number 84 Light Fixture 042229500 1 85 Bulb- LT10 065492402 1 86 Junction Box 065491901 1 87 Junction Box Cover 065492001 1 88 Light Switch- S10 065492201 1 89 Receptacle- REC10 030187000 1

LT10- Supply Fan Light/S10- Supply FanLight Switch/REC10- Supply Fan ReceptacleCode 49= B, E

98

99

Ref. Part Part Qty. No. Description Number 98 Light Fixture- 18” Bulb 205484001 1 Light Fixture- 24” Bulb 205484101 1 Light Fixture- 36” Bulb 205484201 1 99 Bulb/Lamp, UV- 18” 205484501 1 Bulb/Lamp, UV- 24” 205484601 1 Bulb/Lamp, UV- 36” 205484701 1

UV LightsCode 17= C1 thru C8 AND Y1 thru Y8

Ref. Part Part Qty. No. Description Number 15 Bracket 1 1 19 Pressure Control- PC7 1 1 20 Pneumatic Fitting 1 1

PC7- Proof of Airflow Pressure Control

1 In mid 2012 the design of PC7 was changed. Units equipped with the old style PC7 require Retrofit Kit 910122413 for proper installation as old and new parts are NOT interchangeable. The Switch only is p/n 910115489, the Pneumatic Fitting is p/n 910122414, and the Support Bracket is p/n 910122290.

19

15

20

84 85

86 87

88 89

Page 93: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 93

Section F- Supply Air SectionSection Mounted Controls

MAT, EFT, SAT, DAT, OAT, SD1

50

51

Ref. Part Part Qty. No. Description Number 50 Smoke Detector- SD1 098873101 1 51 Sensing Tube 049025002 1

Smoke Detector- SD1Code 16= 2, 3

Ref. Part Part Qty. No. Description Number 7 OAT Temp. Sensor 193414602 1

Outdoor Air Temperature Sensor- OAT7

8

OAT

SAT/DAT

Smoke Detector

Detail

Ref. Part Part Qty. No. Description Number 8 SAT/DAT Temp. Sensor 193414602 1

Supply Air Temperature Sensor- SAT ORDischarge Air Temperature Sensor- DAT

5

MAT/EFT

Ref. Part Part Qty. No. Description Number 5 EFT/MAT Temp. Sensor 193414602 1

Mixed Air Temperature Sensor- MAT OREntering Fan Temperature Sensor- EFT

Page 94: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 94

Section F- Supply Air SectionSection Mounted Controls

SCB- Split Junction Box (Code 05= F) TB25, TB27, TB28, PB10, PB9, PB20, PB19

TB28 TB27 TB25

PB 19 PB 20 PB 9 PB 10

Motor HP 2- 25 30 40, 50 Sch. Part Part Sym. Description Number Terminal Blocks TB25 Terminal Block- SCB 015998124 1 1 1 1 1 1 1 1 1 1 1 1 TB27 Terminal Block- SCB 015998130 1 1 1 1 1 1 1 1 1 1 1 1 TB28 1 Terminal Block- SCB 015998124 1 1 1 1 1 1 1 1 1 1 1 1 PB10 Power Block- Supply Fan 95A, 600V, 3P 030372707 1 1 1 1 1 1 1 1 1 1 1 1 PB9 Power Block- Supply Fan 95A, 600V, 3P 030372707 1 PB20 Power Block- Return Fan 95A, 600V, 3P 030372707 1 1 1 1 1 1 1 1 PB19 Power Block- Return Fan 95A, 600V, 3P 030372707 1

208V

230V

460V

575V

208V

230V

460V

575V

208V

230V

460V

575V

1 Only used when the unit has a supply fan inverter OR an Economizer with a Power Closure Exhaust Damper.

Page 95: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 95

Section G- BlowThru Heat SectionNotes

Primary Codes that pertain: 04, 34Additional Codes that pertain: 06, 07, 09, 12, 31

This section is divided into four subsections: 1. Blank/Empty Section; 2. HW/Steam Heat; 3. Electric Heat; and 4. Natural Gas Heat.

Code 04 determines what type of heat, if any, the unit employs, and Code 34 defines the specific heat section’s characteristics. If Code 04= Y, and Code 34= YYYYYY there is no section. If Code 04= Y and Code 34= BBBBBB, then there is a 48” Blank Access Section installed.

Code 06 determines the insulation and liners and will affect the Top Panel, Uprights, and Door Assembly part numbers. For sheet metal components that make up the BlowThru Heat Section, contact Daikin Applied to ensure correct liners, insulation and hardware are ordered. For standard Access Door Latching Assemblies, see Section H.

Code 07 is the Gas Heat Burner Approval Code and affects many of the parts in the gas heat section depending on whether the unit is ETA/MEA approved (USA) OR ETL approved (Canada).

Code 09 determines the Unit Voltage, which will have an effect on the Electric Heaters and their controls.

Code 12 determines the Control type and will affect the Gas Heat Actuator.

Code 31 is the Supply Fan size, and affects the heat section’s Diffusers.

Option 1: Blank/Empty SectionCode 34= BBBBBB AND Code 04= Y

Diffuser

12

Ref. Part Part Qty. No. Description Number 12 Diffuser 27” Supply Fan Code 31= 27** 055988001 1 30” Supply Fan Code 31= 30** 055988002 1 33” Supply Fan Code 31= 33** 055988003 1

Page 96: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 96

3

2

Section G- BlowThru Heat SectionOption 2: Hot Water OR Steam Coil Heat, Mixing Valves and Actuator (VM1)

Code 34 first 3 digits = S11, S12, S13, S14, W11, W22

Ref. Sch. Part Code Coil Coil Part Qty. No. Sym. Description 34= Type Height Number 2 Steam Heat Coil- Bottom S11*** 5JA0601H 30” 056053021 1 Steam Heat Coil- Bottom S12*** 5JA1201H 30” 056053022 1 Steam Heat Coil- Bottom S13*** 5JA0602C 30” 056053023 1 Steam Heat Coil- Bottom S14*** 5JA1202C 30” 056053024 1 Hot Water Heat Coil- Bottom W11*** 5WH0901H 30” 056053025 1 Hot Water Heat Coil- Bottom W22*** 5WS0902C 30” 056053026 1 3 Steam Heat Coil- Top S11*** 5JA0601H 27” 056053031 1 Steam Heat Coil- Top S12*** 5JA1201H 27” 056053032 1 Steam Heat Coil- Top S13*** 5JA0602C 27” 056053013 1 Steam Heat Coil- Top S14*** 5JA1202C 27” 056053014 1 Hot Water Heat Coil- Top W11*** 5WH0901H 27” 056053035 1 Hot Water Heat Coil- Top W22*** 5WS0902C 27” 056053016 1 N/S FS1 Freezestat ALL ALL ALL 072502001 1 12 Diffuser- 27” Supply Fan 055988001 1 Diffuser- 30” Supply Fan 055988002 1 Diffuser- 33” Supply Fan 055988003 1 N/S Valve, 2 Way Steam Heat w/ Act.2

1.25” S**E2E 5JA All 113147501 1 1.50” S**F2E 5JA All 113147701 1 2.00” S**G2E 5JA All 113147901 1 2.50” S**H2E 5JA All 113148101 1 163 VM1 Actuator- 24V, 1.25”- 2.00” Valve 1 W****E All All 300046566 1 Actuator- 24V, 2.50”- 3.00” Valve 1 W****E All All 113149601 1 263 Valve, 3 Way HW w/ Actuator 1.25” W**E3E 5WH, 5WS All 113166703 1 1.50” W**F3E 5WH, 5WS All 113166704 1 2.00” W**G3E 5WH, 5WS All 113166705 1 2.50” W**H3E 5WH, 5WS All 113166706 1 3.00” W**J3E 5WH, 5WS All 113166707 1

Coil Location Mixing Valve Detail(HW shown)

12

Diffuser

163

263

N/S= Not shown on diagram.1 Note that the HW Valve is factory supplied WITH the Actuator. Use this p/n when replacing the HW Actuator ONLY.2 Note that the Steam Valve is factory supplied WITH the Actuator. For Actuator ONLY p/ns contact Daikin Applied with model and

serial number information so that the correct Actuator can be identified.

Page 97: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 97

Section G- BlowThru Heat SectionOption 3: Electric Heat: Code 34 first digit= E

Heaters, Diffusers, Hi Limit Cutouts HL1- 20, 31- 50Diagram & Components

6

5

12

7

Hi Limit Cutout Unit with with Voltage Auto and Auto Ref. Sch. Part Total Code Heater Manual Cutout No. Sym. Description KW 34= KW Cutout 1 Only 2

5 Heater Assy- Top 40 E040 40 049269208 049269217 1 Heater Assy- Top 40 E040 40 049269226 049269235 1 Heater Assy- Top 40 E040 40 N/A 049269244 1 Heater Assy- Top 60 E060 60 049269207 049269216 1 Heater Assy- Top 60 E060 60 049269225 049269234 1 Heater Assy- Top 60 E060 60 N/A 049269243 1 Heater Assy- Top 80 E080 80 049269206 049269215 1 Heater Assy- Top 80 E080 80 049269224 049269233 1 Heater Assy- Top 80 E080 80 N/A 049269242 1 Heater Assy- Top 100 E100 100 049269205 049269214 1 Heater Assy- Top 100 E100 100 049269223 049269232 1 Heater Assy- Top 100 E100 100 N/A 049269241 1 Heater Assy- Top 120 E120 120 049269204 049269213 1 Heater Assy- Top 120 E120 120 049269222 049269231 1 Heater Assy- Top 120 E120 120 N/A 049269240 1 Heater Assy- Top 160 E160 160 049269203 049269212 1 Heater Assy- Top 160 E160 160 049269221 049269230 1 Heater Assy- Top 160 E160 160 N/A 049269239 1 Heater Assy- Top 200 E200 120 049269201 049269210 1 Heater Assy- Top 200 E200 120 049269219 049269228 1 Heater Assy- Top 200 E200 120 N/A 049269237 1 Heater Assy- Top 240 E240 120 049269201 049269210 1 Heater Assy- Top 240 E240 120 049269219 049269228 1 Heater Assy- Top 240 E240 120 N/A 049269237 1

208/

230V

460V

575V

7A

N/A= Not Applicable.1 Units ETL/MEA approval (Code 07= EY) OR no approval (Code 07= YY). Heater assy includes Hi Limit auto and manual reset switches.2 Units Canada approval (Code 07= CY). Heater assy includes Hi Limit auto reset switches.

Air

Flow

Page 98: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 98

Section G- BlowThru Heat SectionOption 3: Electric Heat: Code 34 first digit= E

Heaters, Diffusers, Hi Limit Cutouts HL1- 20, 31- 50Components, Continued

Hi Limit Cutout Unit with with Voltage Auto and Auto Ref. Sch. Part Total Code Heater Manual Cutout No. Sym. Description KW 34= KW Cutout 1 Only 2

6 Blank Assy- Bottom 40- 160 E/040- 160 055923601 055923601 1 1 1 Heater Assy- Bottom 200 E200 80 049269202 049269211 1 Heater Assy- Bottom 200 E200 80 049269220 049269229 1 Heater Assy- Bottom 200 E200 80 N/A 049269238 1 Heater Assy- Bottom 240 E240 120 049269201 049269210 1 Heater Assy- Bottom 240 E240 120 049269219 049269228 1 Heater Assy- Bottom 240 E240 120 N/A 049269237 1 7 HL1-20 Hi Limit- Manual Cutout All All All 065496201 N/A var var var 7A HL31-50 Hi Limit- Auto Cutout All All All 065824501 065824201 var var var 12 Diffuser All All All 055645701 055645201 1 1 1

208/

230V

460V

575V

N/A= Not Applicable.1 Units ETL/MEA approval (Code 07= EY) OR no approval (Code 07= YY). Heater assy includes Hi Limit auto and manual reset switches.2 Units Canada approval (Code 07= CY). Heater assy includes Hi Limit auto reset switches.

Page 99: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 99

Section G- BlowThru Heat SectionOption 3: Electric Heat: Code 34 first digit= EElectric Heat Control Box: (03/2013 & Earlier)

208/230V20KW- 160KW

460/575V20KW- 160KW

460/575V200KW- 240KW

FB33 FB37 FB32 FB36 FB31 FB35

M33 M37 M32 M36 M31 M35

M34 M38

FB34 FB38

HS3

DS3or

PB3

FB33 FB32 FB31

FB34

M33

M34

M32 M31

HS3

DS3or

PB3

TB11

FB33 FB32 FB31

FB41

M33

M41

M32 M31

HS3

DS3or

PB3

FB42FB43

M42M43

TB11

TB11

PB31 PB31 PB31

DS3- Disconnect Switch 1

Sch. Part Disconnect Switch Component Sym. Description Amps Switch Handle 2 Shaft Ground Lug DS3 Disconnect Switch 100 Amp 349935125 349935523 349962211 349938001 Disconnect Switch 150 Amp 349935126 349935533 349962212 349938001 Disconnect Switch 250 Amp 349935226 349935533 349962212 349938001 Disconnect Switch 400 Amp 349935325 349935622 349962213 349938002 Disconnect Switch 600 Amp 193438206 3 4 349962243 3499380021 Disconnects are sized according to various unit specifications. Check installed switch to verify the correct DS3 size.2 Includes mechanism (except 600A switch, see footnote 4).3 The original “M” frame Disconnect is obsolete and has been replaced with a “P” frame switch. Due to dimensional differences

minor field modifications may be required for proper installation. 4 Handle only p/n 349961102; Mechanism only p/n 193455001; Shaft p/n 349961403.

Page 100: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 100

Heater KW 20 40 60 80 100 120 Sch. Part Part Sym. Description Number PB3 Power Block 030372777 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Power Block 030372785 1 1 1 1 1 1 1 1

PB31 Power Block 3 used w/100A, 150A DS3 030372777 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 used w/250A DS3 030372783 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 used w/400A DS3 030372785 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 used w/600A DS3 030372721 4 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

DS3 Disconnect Switch 2

HS3 Switch 033696300 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

TB11 Terminal Block 349930641 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

M31 Contactor 349932321 1 1 1 1 1 1 Contactor 349932322 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 M32 Contactor 349932322 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Contactor 349932321 1 1 1 1 1 1 M33 Contactor 349932322 1 1 1 1 1 1 1 1 Contactor 349932321 1 1 1 1 1 1 M34 Contactor 349932322 1 1 1 1 1 1 1 1 Contactor 349932321 1 1 1 1 1 1 M35 Contactor 349932322 1 1 1 1 M36 Contactor 349932322 1 1

208V

230V

460V

575V

208

V23

0V46

0V57

5V 2

08V

230V

460V

575V

208

V23

0V46

0V57

5V 2

08V

230V

460V

575V

208

V23

0V46

0V57

5V

1 Part number is for one section. The number of sections used is determined by the options installed.2 See chart on previous page.3 Not Used when PB3 Power Block connection is present.4 Cover- PB31 for 600A DS3= p/n 349938345.

Section G- BlowThru Heat SectionOption 3: Electric Heat: Code 34 first digit= EElectric Heat Control Box: (03/2013 & Earlier)

20- 120KW Components

Page 101: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 101

Heater KW 20 40 60 80 100 120 Sch. Part Part Sym. Description Number FB31 Fuse Block 023780229 1 1 1 1 1 1 1 1 1 1 1 1 Fuse Block 023780225 1 1 1 1 1 1 Fuse Block 023780230 1 1 1 1 1 1 FB32 Fuse Block 023780229 1 1 1 1 1 1 1 1 1 1 Fuse Block 023780225 1 1 1 1 1 1 Fuse Block 023780230 1 1 1 1 FB33 Fuse Block 023780229 1 1 1 1 1 1 1 1 Fuse Block 023780225 1 1 1 1 1 1 FB34 Fuse Block 023780229 1 1 1 1 1 1 1 1 Fuse Block 023780225 1 1 1 1 1 1 FB35 Fuse Block 023780229 1 1 1 1 FB36 Fuse Block 023780229 1 1

F31 Fuse- FB31 025860514 3 3 3 3 3 3 3 3 3 3 Fuse- FB31 025860511 3 Fuse- FB31 025860512 3 Fuse- FB31 025860409 3 3 3 Fuse- FB31 025860408 3 3 3 Fuse- FB31 025860412 3 Fuse- FB31 025860411 3 Fuse- FB31 025860414 3 3 Fuse- FB31 025860413 3 3 F32 Fuse- FB32 025860514 3 3 3 3 3 3 3 3 Fuse- FB32 025860511 3 Fuse- FB32 025860512 3 Fuse- FB32 025860409 3 3 3 Fuse- FB32 025860408 3 3 3 Fuse- FB32 025860412 3 Fuse- FB32 025860411 3 Fuse- FB32 025860414 3 Fuse- FB32 025860413 3 F33 Fuse- FB33 025860511 3 Fuse- FB33 025860512 3 Fuse- FB33 025860514 3 3 3 3 3 3 Fuse- FB33 025860409 3 3 3 Fuse- FB33 025860408 3 3 3 F34 Fuse- FB34 025860511 3 Fuse- FB34 025860512 3 Fuse- FB34 025860514 3 3 3 3 3 3 Fuse- FB34 025860409 3 3 3 Fuse- FB34 025860408 3 3 3 F35 Fuse- FB35 025860514 3 3 3 3 F36 Fuse- FB36 025860514 3 3

208V

230V

460V

575V

208

V23

0V46

0V57

5V 2

08V

230V

460V

575V

208

V23

0V46

0V57

5V 2

08V

230V

460V

575V

208

V23

0V46

0V57

5V

Section G- BlowThru Heat SectionOption 3: Electric Heat: Code 34 first digit = EElectric Heat Control Box: (03/2013 & Earlier)

20- 120KW Components, Continued

Page 102: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 102

Heater KW 160 200 240 Sch. Part Part Sym. Description Number PB3 Power Block 030372785 1 1 1 1 Power Block 030372786 1 1 1 1 PB31 Power Block 3 used w/100A/150A DS3 030372777 1 1 1 1 1 1 1 1 used w/250A DS3 030372783 1 1 1 1 1 1 1 1 used w/400A DS3 030372785 1 1 1 1 1 1 1 1 used w/600A DS3 030372721 4 1 1 1 1 1 1 1 1 DS3 Disconnect Switch 2

HS3 Switch 033696300 1 1 1 1 1 1 1 1 TB11 Terminal Block 349930641 1 1 1 1 1 1 1 1

M31 Contactor 349932322 1 1 1 1 1 1 1 1 M32 Contactor 349932322 1 1 1 1 1 1 1 1 M33 Contactor 349932322 1 1 1 1 1 1 1 1 M34 Contactor 349932322 1 1 1 1 M35 Contactor 349932322 1 1 M36 Contactor 349932322 1 1 M37 Contactor 349932322 1 1 M38 Contactor 349932322 1 1 M41 Contactor 349932322 1 1 1 1 M42 Contactor 349932322 1 1 1 1 M43 Contactor 349932322 1 1

208V

230V

460V

575V

460

V57

5V 4

60V

575V

1 Part number is for one section. The number of sections used is determined by the options installed.

2 See chart 3 pages prior.3 Not Used when PB3 Power Block connection is present.4 Cover- PB31 for 600A DS3= p/n 349938345.

Section G- BlowThru Heat SectionOption 3: Electric Heat: Code 34 first digit = EElectric Heat Control Box: (03/2013 & Earlier)

160- 240KW Components

Page 103: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 103

Heater KW= 160 200 240 Sch. Part Part Sym. Description Number FB31 Fuse Block 023780229 1 1 Fuse Block 023780230 1 1 1 1 1 1 FB32 Fuse Block 023780229 1 1 Fuse Block 023780225 Fuse Block 023780230 1 1 1 1 1 1 FB33 Fuse Block 023780229 1 1 Fuse Block 023780230 1 1 1 1 1 1 FB34 Fuse Block 023780229 1 1 Fuse Block 023780230 1 1 FB35 Fuse Block 023780229 1 1 FB36 Fuse Block 023780229 1 1 FB37 Fuse Block 023780229 1 1 FB38 Fuse Block 023780229 1 1 FB41 Fuse Block 023780230 1 1 1 1 FB42 Fuse Block 023780230 1 1 1 1 FB43 Fuse Block 023780230 1 1

F31 Fuse- FB31 025860514 3 3 Fuse- FB31 025860414 3 3 3 Fuse- FB31 025860413 3 3 3 F32 Fuse- FB32 025860514 3 3 Fuse- FB32 025860414 3 3 3 Fuse- FB32 025860413 3 3 3 F33 Fuse- FB33 025860514 3 3 Fuse- FB33 025860414 3 3 3 Fuse- FB33 025860413 3 3 3 F34 Fuse- FB34 025860514 3 3 Fuse- FB34 025860414 3 Fuse- FB34 025860413 3 F35 Fuse- FB35 025860514 3 3 F36 Fuse- FB36 025860514 3 3 F37 Fuse- FB37 025860514 3 3 F38 Fuse- FB38 025860514 3 3 F41 Fuse- FB41 025860414 3 3 Fuse- FB41 025860413 3 3 F42 Fuse- FB42 025860414 3 3 Fuse- FB42 025860413 3 3 F43 Fuse- FB43 025860414 3 Fuse- FB43 025860413 3

208V

230V

460V

575V

460

V57

5V 4

60V

575V

Section G- BlowThru Heat SectionOption 3: Electric Heat: Code 34 first digit = EElectric Heat Control Box: (03/2013 & Earlier)

160- 240KW Components, Continued

Page 104: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 104

Section G- BlowThru Heat SectionOption 3: Electric Heat: Code 34 first digit = EElectric Heat Control Box: (04/2013 & Later)

Diagrams & Components

208/230V20KW- 160KW

460/575V20KW- 160KW

460/575V200KW- 240KW

FB33 FB37 FB32 FB36 FB31 FB35

M33 M37 M32 M36 M31 M35

M34 M38

FB34 FB38

HS3

DS3or

PB3

FB33 FB32 FB31

FB34

M33

M34

M32 M31

HS3

DS3or

PB3

TB11

FB33 FB32 FB31

FB41

M33

M41

M32 M31

HS3

DS3or

PB3

FB42FB43

M42M43

TB11

TB11

PB31 PB31 PB31

Sch. Part Disconnect Switch Component Sym. Description Switch Mechanism Handle Shaft Lugs DS3 Disconnect Switch- 100A 193444703 Not Used 193422102 193596420 2 Not Used Disconnect Switch- 150A 193585101 193550801 193422102 193596420 2 193553301 4

Disconnect Switch- 250A 193551601 193551001 193595701 300049193 3 193553801 4

Disconnect Switch- 400A 193551701 193551001 193595701 300049193 3 193554001 4

Disconnect Switch- 600A 193551801 193551001 193595701 300049193 3 193554101 4

DS3- Disconnect Switch 1

1 Disconnects are sized according to various unit specifications. Check installed Switch to verify the correct DS3 size, or contact Daikin Applied with model and serial number information so that the required part(s) can be identified.

2 This Shaft is 14.25” OAL and is designed to be cut to length in the field.3 This Shaft is 7.21” (183mm) OAL and is designed to be cut to length in the field. For a 19.69” (500mm) OAL use p/n 300040299.4 Three Lugs are included with each p/n.

Page 105: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 105

Heater KW= 20 40 60 80 100 120 Sch. Part Part Sym. Description Number PB3 Power Block 175A 030372777 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Power Block 420A 030372785 1 1 1 1 1 1 1 1

PB31 Power Block 3 used w/100A, 150A DS3 030372777 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 used w/250A DS3 030372783 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 used w/400A DS3 030372785 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 used w/600A DS3 030372721 4 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

DS3 Disconnect Switch 2

HS3 Switch 033696300 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

TB11 Terminal Block 349930641 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

M31 Contactor 40A 193591601 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Contactor 12A 193592005 1 1 1 1 1 1 M32 Contactor 40A 193591601 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Contactor 12A 193592005 1 1 1 1 1 1 M33 Contactor 40A 193591601 1 1 1 1 1 1 1 1 Contactor 12A 193592005 1 1 1 1 1 1 M34 Contactor 40A 193591601 1 1 1 1 1 1 1 1 Contactor 12A 193592005 1 1 1 1 1 1 M35 Contactor 40A 193591601 1 1 1 1 M36 Contactor 40A 193591601 1 1 1 1

208V

230V

460V

575V

208

V23

0V46

0V57

5V 2

08V

230V

460V

575V

208

V23

0V46

0V57

5V 2

08V

230V

460V

575V

208

V23

0V46

0V57

5V

Section G- BlowThru Heat SectionOption 3: Electric Heat: Code 34 first digit = EElectric Heat Control Box: (04/2013 & Later)

20- 120KW Components

1 Part number is for one section. The number of sections used is determined by the options installed.2 See the chart on the previous page.3 Not Used when PB3 Power Block connection is present.4 Cover- PB31 used with 600A DS3 is p/n 349938345.

Page 106: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 106

Heater KW= 20 40 60 80 100 120 Sch. Part Part Sym. Description Number FB31 Fuse Block 023780229 1 1 1 1 1 1 1 1 1 1 1 1 Fuse Block 023780225 1 1 1 1 1 1 Fuse Block 023780230 1 1 1 1 1 1 FB32 Fuse Block 023780229 1 1 1 1 1 1 1 1 1 1 Fuse Block 023780225 1 1 1 1 1 1 Fuse Block 023780230 1 1 1 1 FB33 Fuse Block 023780229 1 1 1 1 1 1 1 1 Fuse Block 023780225 1 1 1 1 1 1 FB34 Fuse Block 023780229 1 1 1 1 1 1 1 1 Fuse Block 023780225 1 1 1 1 1 1 FB35 Fuse Block 023780229 1 1 1 1 FB36 Fuse Block 023780229 1 1

F31 Fuse- FB31 025860514 3 3 3 3 3 3 3 3 3 3 Fuse- FB31 025860511 3 Fuse- FB31 025860512 3 Fuse- FB31 025860409 3 3 3 Fuse- FB31 025860408 3 3 3 Fuse- FB31 025860412 3 Fuse- FB31 025860411 3 Fuse- FB31 025860414 3 3 Fuse- FB31 025860413 3 3 F32 Fuse- FB32 025860514 3 3 3 3 3 3 3 3 Fuse- FB32 025860511 3 Fuse- FB32 025860512 3 Fuse- FB32 025860409 3 3 3 Fuse- FB32 025860408 3 3 3 Fuse- FB32 025860412 3 Fuse- FB32 025860411 3 Fuse- FB32 025860414 3 Fuse- FB32 025860413 3 F33 Fuse- FB33 025860511 3 Fuse- FB33 025860512 3 Fuse- FB33 025860514 3 3 3 3 3 3 Fuse- FB33 025860409 3 3 3 Fuse- FB33 025860408 3 3 3 F34 Fuse- FB34 025860511 3 Fuse- FB34 025860512 3 Fuse- FB34 025860514 3 3 3 3 3 3 Fuse- FB34 025860409 3 3 3 Fuse- FB34 025860408 3 3 3 F35 Fuse- FB35 025860514 3 3 3 3 F36 Fuse- FB36 025860514 3 3

208V

230V

460V

575V

208

V23

0V46

0V57

5V 2

08V

230V

460V

575V

208

V23

0V46

0V57

5V 2

08V

230V

460V

575V

208

V23

0V46

0V57

5V

Section G- BlowThru Heat SectionOption 3: Electric Heat: Code 34 first digit = EElectric Heat Control Box: (04/2013 & Later)

20- 120KW Components, Continued

Page 107: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 107

Heater KW= 160 200 240 Sch. Part Part Sym. Description Number PB3 Power Block 030372785 1 1 1 1 Power Block 030372786 1 1 1 1 PB31 Power Block 3 used w/100A/150A DS3 030372777 1 1 1 1 1 1 1 1 used w/250A DS3 030372783 1 1 1 1 1 1 1 1 used w/400A DS3 030372785 1 1 1 1 1 1 1 1 used w/600A DS3 030372721 4 1 1 1 1 1 1 1 1 DS3 Disconnect Switch 2

HS3 Switch 033696300 1 1 1 1 1 1 1 1 TB11 Terminal Block 349930641 1 1 1 1 1 1 1 1

M31 Contactor 40A 193591601 1 1 1 1 1 1 1 1 M32 Contactor 40A 193591601 1 1 1 1 1 1 1 1 M33 Contactor 40A 193591601 1 1 1 1 1 1 1 1 M34 Contactor 40A 193591601 1 1 1 1 M35 Contactor 40A 193591601 1 1 M36 Contactor 40A 193591601 1 1 M37 Contactor 40A 193591601 1 1 M38 Contactor 40A 193591601 1 1 M41 Contactor 40A 193591601 1 1 M42 Contactor 40A 193591601 1 1 M43 Contactor 40A 193591601 1 1

208V

230V

460V

575V

460

V57

5V 4

60V

575V

1 Part number is for one section. The number of sections used is determined by the options installed.

2 See chart 3 pages prior.3 Not Used when PB3 Power Block connection is present.4 Cover- PB31 for 600A DS3= p/n 349938345.

Section G- BlowThru Heat SectionOption 3: Electric Heat: Code 34 first digit = EElectric Heat Control Box: (04/2013 & Later)

160- 240KW Components

Page 108: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 108

Heater KW= 160 200 240 Sch. Part Part Sym. Description Number FB31 Fuse Block 023780229 1 1 Fuse Block 023780230 1 1 1 1 1 1 FB32 Fuse Block 023780229 1 1 Fuse Block 023780225 Fuse Block 023780230 1 1 1 1 1 1 FB33 Fuse Block 023780229 1 1 Fuse Block 023780230 1 1 1 1 1 1 FB34 Fuse Block 023780229 1 1 Fuse Block 023780230 1 1 FB35 Fuse Block 023780229 1 1 FB36 Fuse Block 023780229 1 1 FB37 Fuse Block 023780229 1 1 FB38 Fuse Block 023780229 1 1 FB41 Fuse Block 023780230 1 1 1 1 FB42 Fuse Block 023780230 1 1 1 1 FB43 Fuse Block 023780230 1 1

F31 Fuse- FB31 025860514 3 3 Fuse- FB31 025860414 3 3 3 Fuse- FB31 025860413 3 3 3 F32 Fuse- FB32 025860514 3 3 Fuse- FB32 025860414 3 3 3 Fuse- FB32 025860413 3 3 3 F33 Fuse- FB33 025860514 3 3 Fuse- FB33 025860414 3 3 3 Fuse- FB33 025860413 3 3 3 F34 Fuse- FB34 025860514 3 3 Fuse- FB34 025860414 3 Fuse- FB34 025860413 3 F35 Fuse- FB35 025860514 3 3 F36 Fuse- FB36 025860514 3 3 F37 Fuse- FB37 025860514 3 3 F38 Fuse- FB38 025860514 3 3 F41 Fuse- FB41 025860414 3 3 Fuse- FB41 025860413 3 3 F42 Fuse- FB42 025860414 3 3 Fuse- FB42 025860413 3 3 F43 Fuse- FB43 025860414 3 Fuse- FB43 025860413 3

208V

230V

460V

575V

460

V57

5V 4

60V

575V

Section G- BlowThru Heat SectionOption 3: Electric Heat: Code 34 first digit = EElectric Heat Control Box: (04/2013 & Later)

160- 240KW Components, Continued

Page 109: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 109

Section G- BlowThru Heat SectionOption 4- Gas Heat Code 04= AHeat Exchangers & Vestibules

200, 250 MBH Furnaces Code 34= 020**, 025**

Ref. Part 200, 250 Qty. No. Description MBH 1 Heat Exchanger Kit 098322511 1 1 21 Vestibule 055636308 1 22 Vestibule 055636303 1 38 Capillary Plate 059360301 1 N/S Turbulator Assy. 034150401 2 8N/S= Not shown on diagram.1 Kit includes the Heat Exchanger, Flue Front Cover, Flue Back Cover, Inspection Door, and Inspection Door Gasket.2 Note that Turbulators are NOT furnished with the Heat Exchanger. Turbulator Assemblies must be ordered separately. 3 Parts detail follows this section.4 Parts detail follows Burner section.5 Parts detail follows Burner Control Box section.

38

21

22

HeatExchanger

Burner 3

BurnerControlBox 4

Gas Train 5

1

Page 110: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 110

Section G- BlowThru Heat SectionOption 4- Gas Heat Code 04= AHeat Exchangers & Vestibules

320, 400, 500, 640, 650, 790, 800, 1000 MBH FurnacesCode 34= 032**, 040**, 050**, 064**, 065**, 079**, 080**, 100**

Ref. Part 320, 400 500, 640 650, 790 800, 1000 Qty. No. Description MBH MBH MBH MBH 300 Heat Exchanger Kit 098322512 1 098322513 1 098322514 1 098322515 1 1 21 Vestibule 055636309 055636309 055636309 055636309 1 22 Vestibule 055636304 055636305 055636306 055636307 1 N/S Turbulator 058387201 058387201 058387201 058387201 2

21

22

HeatExchanger

Burner 3

BurnerControl

Box 4

Gas Train 5

300

N/S= Not shown on diagram.1 Kit includes the Heat Exchanger, Flue Front Cover, Flue Back Cover, Inspection Door, and Inspection Door Gasket.2 Quantity varies depending upon the size of the Heat Exchanger. For 320/400 MBH order 6 pc.; for 500/640 MBH order 9 pc.; for

650/790 MBH order 12 pc.; for 800/1000 MBH order 15 pc. Note that Turbulators are NOT furnished with the Heat Exchanger Kit. 3 Parts detail follows this section.4 Parts detail follows Burner section.5 Parts detail follows Burner Control Box section.

Page 111: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 111

Section G- BlowThru Heat SectionOption 4- Gas Heat: Code 04= A

Modulating Burner:Code 34= ****E*, ****R*, ****S*

Diagrams

109

113

149102115

147119

125

Burner Control Box

114 112124

116

117

105

145

110

142

143 130144

122

111

106

126120

127118

121

103104

107 108

123

160

161

Pilot Valve/ Pressure Regulator Assy Detail

200, 250, 320 MBH Burners

400- 1000 MBH Burners

160

162

Burner Control

Box

Page 112: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 112

Section G- BlowThru Heat SectionOption 4- Gas Heat: Code 04= A

Modulating Burner:Code 34= ****E*, ****R*, ****S*

Components

Burner Approval Code Qty. Ref. Part C07= EU, EF, EI C07= CC, CD No. Description USA Canada 102 Burner Housing 059362302 059362302 1 103 Scroll 035740701 035740701 1 104 Wheel- .5” bore 034861102 034861102 1 105 Motor- .25 HP, 115/60/1 034249200 034249200 1 106 Gun Assembly 200 MBH Furnace 034879901 034879901 1 250 MBH Furnace 034879902 034879902 1 320 MBH Furnace 034879903 034879903 1 400 MBH Furnace 034879904 034879904 1 500 MBH Furnace 034880001 034880001 1 640 MBH Furnace 034880002 034880002 1 650 MBH Furnace 034880002 034880002 1 790 MBH Furnace 034880003 034880003 1 800 MBH Furnace 034880003 034880003 1 1000 MBH Furnace 034880004 034880004 1 107 Inlet Funnel 034743101 034743101 1 108 Fan Guard 034742800 034742800 1 109 Blast Tube 200- 400 MBH Furnace 037378802 037378802 1 500- 650 MBH Furnace 034101703 034101703 1 790- 1000 MBH Furnace 034101707 034101707 1 110 Pilot Mixer 036516401 036516401 1 111 Pilot Assembly 035019600 035019600 1 112 Damper Assembly 035721501 048791401 1 113 Blast Tube Gasket 034102000 034102000 1 114 Right Side Damper 200- 500 MBH Furnace 058594301 058594301 1 640 MBH Furnace 058595201 058595201 1 650- 1000 MBH Furnace 058594501 058594501 1 115 Left Side Damper 200- 640 MBH Furnace 058595001 058595001 1 650- 1000 MBH Furnace 058594401 058594401 1 116 Slide Damper 200 MBH Furnace 058594801 058594811 1 250 MBH Furnace 058594802 058594812 1 320 MBH Furnace 058594803 058594813 1 400 MBH Furnace 058594804 058594814 1 500 MBH Furnace 058594805 058594815 1 640 MBH Furnace 058594806 058594816 1 650 MBH Furnace 058594807 058594817 1 790 MBH Furnace 058594808 058594818 1 800 MBH Furnace 058594809 058594819 1 1000 MBH Furnace 058594810 058594820 1

Page 113: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 113

Section G- BlowThru Heat SectionOption 4- Gas Heat: Code 04= A

Modulating Burner:Code 34= ****E*, ****R*, ****S*

Components, Continued Burner Approval Code Qty. Ref. Part C07= EU, EF, EI C07= CC, CD No. Description USA Canada 117 Blower Gasket 035019500 035019500 1 118 Burner Cover 033972100 033972100 1 119 Ignition Assembly 1 1 1 120 Glass Cover 036557000 036557000 1 121 Glass Cover Support 036009600 036009600 1 122 Orifice 200 MBH Furnace 058599301 058599301 1 250 MBH Furnace 058599302 058599302 1 320 MBH Furnace 058599303 058599303 1 400 MBH Furnace 059861501 059861501 1 500 MBH Furnace 058599101 058599101 1 640 MBH Furnace 058599102 058599102 1 650 MBH Furnace 058599103 058599103 1 790 MBH Furnace 058599104 058599104 1 800 MBH Furnace 058599104 058599104 1 1000 MBH Furnace 058599201 058599201 1 123 Clip 034919400 034919400 1 124 Flange Bearing 034252000 034252000 2 125 Air Switch Tube 034102801 034102801 1 126 Pilot Burner Tube 200- 400 MBH Furnace 036236000 036236000 1 500- 1000 MBH Furnace 036236100 036236100 1 127 Compression Fitting 034097500 034097500 1 130 Pilot Tube 034102601 034102601 1 142 Manual Cock Valve- 200- 320 MBH only Not Used 034077300 1 143 Press. Reg. Valve- 200- 320 MBH only Not Used 034077600 1 144 90º Comp. Elbow- 200- 320 MBH only Not Used 034097200 1 145 Motor Conduit Box- 200- 320 MBH only 036558800 036558800 1 147 Torsion Spring Not Used 037528600 1 149 Burner Box Baffle 200- 400 MBH Furnace 058597901 058597901 1 500- 1000 MBH Furnace 058597902 058597902 1 160 Valve- Pressure Regulator 034077600 034077600 1 161 Valve- Manual: 200- 320 MBH 034077300 034077300 1 162 Valve- Solenoid: 400- 1000 MBH 034488400 034488400 1 N/S Flame Rod 036557700 036557700 1 N/S Ignition Electrode Assy. 300032902 300032902 1N/S= Not shown on diagram.1 Contact Daikin Applied with model and serial number information so that the correct part can be identified.

Page 114: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 114

Section G- BlowThru Heat SectionOption 4- Gas Heat: Code 04= A

Hi Turn Down Burner:Code 34= ****H*, ****T*, ****U*

Diagrams

119

328102

109

113

295

300

310318

358

110

106

121120

118

105

117

103

104 107108

358

114

297

322

321

323320

299

144

110

325

324

116

Detail: Orifice, Control Rod, Control Arm, Linkage, Plate Detail

200- 400 MBH

324

500- 1000 MBH

375

145

Page 115: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 115

Burner Approval Code Qty. Ref. Part C07= EU, EF, EI C07= CC, CD No. Description USA Canada 102 Burner Housing 059862103 059862103 1 103 Scroll 200- 800 MBH Furnace 096434806 096434806 1 1000 MBH Furnace 059862136 059862136 1 104 Wheel- .5” bore 200- 800 MBH Furnace 034861102 034861102 1 1000 MBH Furnace 034249005 034249005 1 105 Motor- .25 HP, 115/60/1 200- 800 MBH Furnace 034249200 034249200 1 1000 MBH Furnace 032248600 032248600 1 106 Gun Assembly 200 MBH Furnace 096414801 N/A 1 250 MBH Furnace 096414802 N/A 1 320 MBH Furnace 096414803 N/A 1 400 MBH Furnace 096414804 096414804 1 500 MBH Furnace 096414805 096414805 1 640 MBH Furnace 096414806 096414806 1 650 MBH Furnace 096414806 096414806 1 790 MBH Furnace 096414808 096414808 1 800 MBH Furnace 096414808 096414808 1 1000 MBH Furnace 096414810 096414810 1 107 Inlet Funnel 200- 800 MBH Furnace 034743101 034743101 1 1000 MBH Furnace 034743102 034743102 1 108 Fan Guard 034742800 034742800 1 109 Blast Tube 200- 400 MBH Furnace 037378802 037378802 1 500 MBH Furnace 034101703 034101703 1 640 MBH Furnace 034101703 034101707 1 650- 1000 MBH Furnace 034101707 034101707 1

Section G- BlowThru Heat SectionOption 4- Gas Heat: Code 04= A

Hi Turn Down BurnerCode 34= ****H*, ****T*, ****U*

Components

N/A= Not available.

Page 116: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 116

Burner Approval Code Qty. Ref. Part C07= EU, EF, EI C07= CC, CD No. Description USA Canada 110 Orifice Assembly 200 MBH Furnace 096414701 N/A 1 250 MBH Furnace 096414702 N/A 1 320 MBH Furnace 096414703 N/A 1 400 MBH Furnace 096414704 096414724 1 500 MBH Furnace 096414705 096414725 1 640 MBH Furnace 096414706 096414726 1 650 MBH Furnace 096414707 096414727 1 790 & 800 MBH Furnace 096414708 096414728 1 1000 MBH Furnace 096414710 096414730 1 113 Gasket- Blast Tube 034102000 034102000 1 114 Air Box Assy 059862112 059862112 1 116 Plate- Actuator Scale 059645001 059645001 1 117 Gasket- Blower 035019500 035019500 1 118 Panel- Burner Box Cover 059388501 059388501 1 119 Ignition Wire Assy 2 2 1 120 Glass Cover- Burner 036557000 036557000 1 121 Support- Glass Cover 036009600 036009600 1 144 Grommet- Flat 060017701 060017701 1 145 Box- Conduit 036558800 036558800 1 295 Motor- Actuator 120V 111047701 1 111047701 1 1 Motor- Actuator 24V 113157801 1 113157801 1 1 297 Control Arm 059862114 059862114 1 299 Control Rod 059861101 059861101 1 300 Crank Arm 059645101 059645101 1 310 Extension- Crank Arm 059862110 059862110 1 318 Bushing- Control Rod 059861301 059861301 1 320 Linkage 096414901 096414901 1 321 Plate- Adjustable 200 MBH Furnace 096422001 N/A 1 250 MBH Furnace 096421601 N/A 1 320 MBH Furnace 059389601 N/A 1 400 MBH Furnace 096423001 096423101 1 500 MBH Furnace 060086401 096422901 1 640 MBH Furnace 096417701 096417801 1 650 MBH Furnace 096416301 096416301 1 790 MBH Furnace 060097101 060097101 1 800 MBH Furnace 060097101 096422701 1 1000 MBH Furnace 060092401 060097301 1

Section G- BlowThru Heat SectionOption 4- Gas Heat: Code 04= A

Hi Turn Down BurnerCode 34= ****H*, ****T*, ****U*

Components, Continued

N/A= Not available.1 Normally units without controls (Code 12= YM, YC) use a 120V Actuator and units with controls (Code 12= *D, *S, *E,

*F, *W) use a 24V Actuator. Confirm voltage required BEFORE ordering.2 Contact Daikin Applied with model and serial number information so that the correct part can be identified.

Page 117: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 117

Burner Approval Code Qty. Ref. Part C07= EU, EF, EI C07= CC, CD No. Description USA Canada 322 Plate- Profile 200, 250 MBH Furnaces 096421501 N/A 1 320 MBH Furnace 059389001 N/A 1 400 MBH Furnace 060097601 060097601 1 500 MBH Furnace 060086101 060086101 1 640 MBH Furnace 096417901 096417901 1 650 MBH Furnace 096415301 096418001 1 790 MBH Furnace 096416501 096416501 1 800 MBH Furnace 060096901 060097001 1 1000 MBH 060092601 060097201 1 323 Plate- Slide Damper 200, 250, 320, 400 MBH Furnaces 059388801 059388801 1 500 MBH Furnace 060086301 060086301 1 640, 650 MBH Furnaces 096417601 096417601 1 790, 800, 1000 MBH Furnaces 060092501 060092501 1 324 Box- Air 200- 400 MBH Furnaces 059869101 059869101 1 500- 1000 MBH Furnaces 060092201 060092201 1 325 Gasket- Air Box 060092301 060092301 1 328 Grommet 000498100 000498100 1 358 Bearing- Sleeve 046761000 046761000 2 375 Grommet 500- 1000 MBH only 059988700 059988700 1

Section G- BlowThru Heat SectionOption 4- Gas Heat: Code 04= A

Hi Turn Down BurnerCode 34= ****H*, ****T*, ****U*

Components, Continued

Page 118: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 118

FSG Detail

24

34

26

25

39

3130

32

29

GasControl

Box

63

2227

4125

61

11

Section G- BlowThru Heat SectionOption 4- Gas Heat: Code 04= A

Modulating Burner Controls: Code 34= ****E*, ****R*, ****S*

No Controls (Code 12= YM, YC)Diagram

Page 119: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 119

Section G- BlowThru Heat SectionOption 4- Gas Heat: Code 04= A

Modulating Burner Controls: Code 34= ****E*, ****R*, ****S*

No Controls (Code 12= YM, YC)Components

Ref. Sch. Part Furnace MBH Qty. No. Sym. Description 200, 250 320 400- 1000 11 GV1 Pressure Reg. Assy 061530300 061530300 039742000 1 Valve Only 034077600 034077600 034077600 1 Manual Cock Valve 034077300 034077300 Not Used 1 Solenoid Valve Not Used Not Used 034488400 1 22 Support 059388701 059388701 Not Used 1 24 Flame Safeguard Subbase 073300702 073300702 073300702 1 25 FSG Flame Safeguard 073300801 073300801 073300801 1 26 Amplifier 073300901 073300901 073300901 1 27 Flame Safeguard T.D. 90 Sec. Modulating Burner/UL Units 073301002 073301002 073301002 1 Flame Safeguard T.D. 30 Sec. Modulating Burner/Canada 073301001 073301001 073301001 1 29 S3 Toggle Switch- 4PST: S3 033536700 033536700 033536700 1 30 IT Ignition Transformer 034482600 034482600 034482600 1 31 Air Switch- Gas Burner 033003800 033003800 033003800 1 32 FLC Fan Limit Control 193423703 1 193423703 1 193423703 1 1 34 TB11 Terminal 349930641 349930641 349930641 20 Terminal Block End Stop 349930841 349930841 349930841 2 Terminal Block End Plate 349930741 349930741 349930741 1 Terminal Block Jumper, 2 Row 349930647 349930647 349930647 1 Terminal Block Jumper, 3P 349930943 349930943 349930943 1 39 Fitting 067297701 067297701 067297701 1 41 Bushing 001242600 001242600 001242600 1 61 R20 Relay (Before 1/10) 061019403 061019403 061019403 1 N/S R20A Relay (After 1/10) 349934764 349934764 349934764 1 N/S Relay Socket 349964702 349964702 349964702 1 63 R23 Pilot Relay (Before 1/10) 019643000 019643000 019643000 1 N/S R23A Pilot Relay (After 1/10, ETL only) 349934764 349934764 349934764 1 N/S Mounting Adapter 349964702 349964702 349964702 1 N/S R23B Pilot Relay (After 1/10) 193454702 193454702 193454702 1 N/S Relay Socket 193454801 193454801 193454801 1N/S= Not Shown on diagram.1 Note that the sensor is NOT sold separately from the controller.

Page 120: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 120

Section G- BlowThru Heat SectionOption 4- Gas Heat: Code 04= A

Modulating Burner Controls (Code 34= ****E*, ****R*, ****S*)MicroTech III Controls (Code 12= *E, *F, *W)

FSG Detail

24

34

2631

30

32

29Gas

ControlBox

61

63

27

25 62

11

GV1 Detail

Panel Detail

FLC

S3

25FSG

IT

TB11

AS

R23B

R23A

R20A

Ref. Sch. Part Furnace MBH: Qty. No. Sym. Description 200, 250 320 400- 1000 11 GV1 Pressure Reg. Assy 061530300 061530300 039742000 1 Valve Only 034077600 034077600 034077600 1 Manual Cock Valve 034077300 034077300 Not Used 1 Solenoid Valve Not Used Not Used 034488400 1 24 Flame Safeguard Subbase 073300702 073300702 073300702 1 25 FSG Flame Safeguard 073300803 073300803 073300803 1 26 Amplifier 073300901 073300901 073300901 1 27 Flame Safeguard T.D. 90 Sec. Modulating Burner/UL Units 073301002 073301002 073301002 1 Flame Safeguard T.D. 30 Sec. Modulating Burner/Canada 073301001 073301001 073301001 1 29 S3 Toggle Switch- 4PST 033536700 033536700 033536700 1 30 IT Ignition Transformer 034482600 034482600 034482600 1 31 AS Air Switch- Gas Burner 033003800 033003800 033003800 1 32 FLC Fan Limit Control 193423703 1 193423703 1 193423703 1 1 34 TB11 Terminal Block 349930641 349930641 349930641 18 Terminal Block End Stop 349930841 349930841 349930841 2 Terminal Block End Plate 349930741 349930741 349930741 1 Jumper Terminal 349930942 349930942 349930942 1 61 R20A Relay- High Amp DPDT/120V 349934764 349934764 349934764 1 62 R23A Relay- High Amp DPDT/120V 349934764 349934764 349934764 1 63 R23B Relay- Low Amp DPDT/120V 193424341 193424341 193424341 11 Note that the sensor is NOT sold separately from the controller.

Page 121: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 121

FSG Detail

33 42

25

26

23

61

32

29

22

64

See Detail

24

63

34 66 65 41 30

39 31

27

R23

R21

R20

TB11TD11

R22

Section G- BlowThru Heat SectionOption 4- Gas Heat: Code 04= A

Hi Turn Down Burner Controls: Code 34= ****H*, ****T*, ****U*No Controls (Code 12= YM, YC)

Diagram

Page 122: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 122

Section G- BlowThru Heat SectionOption 4- Gas Heat: Code 04= A

Hi Turn Down Burner Controls: Code 34= ****H*, ****T*, ****U*No Controls (Code 12= YM, YC)

Components

Ref. Sch. Part Part Qty. No. Sym. Description Number 22 Support 059388701 1 23 Support 059388601 1 24 Subbase- Flame Safeguard 073300702 1 25 FSG Control- Flame Safeguard 073300803 1 26 Amplifier 073300901 1 27 Time Delay- Flame Safeguard 073301003 1 29 S3 Switch- Toggle 033536700 1 30 IT Transformer- Ignition 034482600 1 31 AS Switch- Air 033003800 1 32 FLC Control- Fan Limit 193423703 1 1 33 LS1/LS2 Switch- Limit 059975301 2 34 TB11 Terminal 349930641 22 Terminal Block End Stop 349930841 2 Terminal Block End Plate 349930741 1 Terminal Block Jumper, 2 Row 349930647 1 Terminal Block Jumper, 3P 349930943 1 39 Fitting 067297701 1 41 Bushing 001242600 1 42 Bushing 049751901 1 61 R20 Relay 120V (Before 1/10) 019643000 1 N/S R20A Relay 120V (After 1/10) 349934764 1 N/S Mounting Adapter 349964702 1 N/S R20B Relay 120V (After 1/10) 193454703 1 Relay Socket 193454801 1 63 R23 Relay- 120V/DPDT (Before 3/10) 019643000 1 N/S R23A Relay 120V (After 1/10) 349934764 1 N/S Mounting Adapter 349964702 1 N/S R23B Relay- 120VSPST (After 3/10) 193454703 1 Relay Socket 193454801 1 64 R21 Relay- 120V/DPDT (Before 3/10) 019643000 1 64 R21 Relay- 120V/DPDT (After 3/10) 193454703 1 Relay Socket 193454801 1 65 R22 Relay- 120VSPST (Before 3/10) 027400700 1 65 R22 Relay- 120VSPST (After 3/10) 349964764 1 N/S Mounting Adapter 349964702 1 66 TD10 Relay- Time Delay 20.0 Sec. 028210106 1 N/S= Not Shown on diagram.1 Note that the sensor is NOT sold separately from the controller.

Page 123: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 123

Section G- BlowThru Heat SectionOption 4- Gas Heat: Code 04= AHi Turn Down Burner Controls: Code 34= ****H*, ****T*, ****U*

MicroTech III Controls (Code 12= *E, *F, *W)

FSG Detail

33

25

26

61

32

29

63

Ref. Sch. Part Part Qty. No. Sym. Description Number 24 Subbase- Flame Safeguard 073300702 1 25 FSG Control- Flame Safeguard 073300803 1 26 Amplifier 073300901 1 27 Time Delay- Flame Safeguard 073301002 1 29 S3 Switch- Toggle 033536700 1 30 IT Transformer- Ignition 034482600 1 31 AS Switch- Air 033003800 1 32 FLC Control- Fan Limit 193423703 1 1 33 LS1/LS2 Switch- Limit 059975301 2 34 TB11 Terminal 349930641 18 Terminal Block End Stop 349930841 2 Terminal Block End Plate 349930741 1 Terminal Block Jumper 349930942 1 61 R20A Relay-High Amp DPDT/120V 349934764 1 62 R20B Relay- Low Amp DPDT/120V 193424341 1 63 R21 Relay- Low Amp DPDT/120V 193424341 1

24

34

62

30

31

27

R21

R20A

TB11

R20B

LS1LS2

IT

FLC

S3

AS

LS1, 2

FSG

1 Note that the sensor is NOT sold separately from the controller.

Page 124: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 124

Section G- BlowThru Heat SectionOption 4- Gas Heat: Code 04= A

Modulating Burner: Code 34= ****E*, ****R*, ****S*Gas Train- Inlet

234

Units without Pressure Regulator Valve Code 34= ****E*

Units with Pressure Regulator Valve Code 34= ****R*, ****S*

228

234

228234

228

234200, 250, 320

MBH Furnaces400, 500, 640, 650, 800

MBH Furnaces 1000 MBH Furnaces

205205

205

Ref. Part Pressure Regulator Qty. No. Description 2- 3 PSI 5- 10 PSI 205 Shutoff Valve 400- 1000 MBH 034077300 034077300 1 228 Pressure Regulator 200, 250, 320 MBH 034078302 034078302 1 400 MBH 036619915 036619916 1 500 MBH 036619914 036619915 1 640, 650 MBH 036619923 036619925 1 790, 800 MBH 036619922 036619924 1 1000 MBH 073387201 036619923 1 234 Gas Valve 200, 250, 320 MBH 073387401 073387401 1 400, 500 MBH 073387402 073387402 1 640- 1000 MBH 073387403 073387403 1

400- 1000 MBH

234

200- 320 MBH

Gas Flow

Gas Flow

Ref. Part Part Qty. No. Description Number 205 Shutoff Valve 400- 1000 MBH 034077300 1 234 Gas Valve 200, 250, 320 MBH 910144815 1 400, 500 MBH 910144816 1 640- 1000 MBH 910144817 1

Page 125: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 125

Section G- BlowThru Heat SectionOption 4- Gas Heat: Code 04= A

Hi Turn Down Burner: Code 34= ****H*, ****T*, ****U*

Gas Train- InletCanada Units— Code 07= CC, CD

226

Units without Pressure Regulator ValveCode 34= ****H*

Units with Pressure Regulator Valve Code 34= ****T*, ****U*

226

232

200- 320 MBH 400- 1000 MBH

226

232

Ref. Part Pressure Regulator Qty. No. Description 2- 3 PSI 5- 10 PSI 226 Shutoff Valve 200, 250, 320 MBH 073387401 073387401 1 400, 500 MBH 073387402 073387402 1 640- 1000 MBH 073387403 073387403 1 232 Pressure Regulator 200, 250, 320 MBH 034078302 034078302 1 400 MBH 036619915 036619916 1 500 MBH 036619914 036619915 1 640, 650 MBH 036619923 036619925 1 790, 800 MBH 036619922 036619924 1 1000 MBH 073387201 036619923 1 292 Valve- Combination 073336504 073336504 1

Combination Valve Detail

292

Back Wall of Vestibule

Combination Valve Detail

292

Back Wall of Vestibule

Gas Flow

Ref. Part Part Qty. No. Description Number 226 Gas Valve 200, 250, 320 MBH 910144815 1 400, 500 MBH 910144816 1 640- 1000 MBH 910144817 1 292 Combination Valve 073336504 1

Page 126: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 126

Section G- BlowThru Heat SectionOption 4- Gas Heat: Code 04= A

Hi Turn Down Burner: Code 34= ****H*, ****T*, ****U*

Gas Train- InletUL Units— Code 07= EU, YU

226

Units without Pressure Regulator ValveCode 34= ****H*

Units with Pressure Regulator Valve Code 34= ****T*, ****U*

226

232

Ref. Part Pressure Regulator Qty. No. Description 2- 3 PSI 5- 10 PSI 226 Shutoff Valve 200, 250, 320 MBH 073387401 073387401 1 400, 500 MBH 073387402 073387402 1 640- 1000 MBH 073387403 073387403 1 232 Pressure Regulator 200, 250, 320 MBH 034078302 034078302 1 400 MBH 036619915 036619916 1 500 MBH 036619914 036619915 1 640, 650 MBH 036619923 036619925 1 790, 800 MBH 036619922 036619924 1 1000 MBH 073387201 073387403 1

Ref. Part Part Qty. No. Description Number 226 Gas Valve 200, 250, 320 MBH 910144815 1 400, 500 MBH 910144816 1 640- 1000 MBH 910144817 1

Page 127: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 127

Section G- BlowThru Heat SectionOption 4- Gas Heat: Code 04= A

Modulating Burner: Code 34= ****E*, ****R*, ****S*

Gas Train- Controls: GV2, GV3UL Units— Code 07= EU, YU

255

261

256

248

255261

256

248 248

253

GV2

GV2 GV3

400- 1000 MBH Furnaces

UL Approved (Code 07= EU, YU)

200- 320 MBH Furnaces Ref. Part Part Qty. No. Description Number 248 Gas Valve- GV2 073336502 1 255 Junction Box 020766100 1 256 Junction Box Cover 000127300 1 261 Gas Pipe 200, 250 MBH 055963904 1 320 MBH 055963903 1

Gas Controls: 200, 250, 320 MBH Furnace

Ref. Part Part Qty. No. Description Number 248 Gas Valve- GV2, GV3 400, 500 MBH 073387801 2 640- 1000 MBH 073387802 2 253 Pressure Regulator 400, 500 MBH 034078100 1 640- 1000 MBH 034077804 1 255 Junction Box 020766100 1 256 Junction Box Cover 000127300 1 261 Gas Pipe 400, 500 MBH 055964001 1 640 MBH 055964101 1 650, 790 MBH 055964106 1 800, 1000 MBH 055964103 1

Gas Controls: 400- 1000 MBH FurnaceUL Approved

Page 128: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 128

Section G- BlowThru Heat SectionOption 4- Gas Heat: Code 04= A

Modulating Burner: Code 34= ****E*, ****R*, ****S*

Gas Train- Controls: GV2, VM1Canada Units— Code 07= CC, CD

255

400- 1000 MBH Furnaces

Canada Approved (Code 07= CC, CD)

261

256

248

GV2

GV2

261249

248

253

200- 320 MBH Furnaces Ref. Part Part Qty. No. Description Number 248 Gas Valve- GV2 073336502 1 255 Junction Box 020766100 1 256 Junction Box Cover 000127300 1 261 Gas Pipe 200, 250 MBH 055963904 1 320 MBH 055963903 1

Gas Controls: 200, 250, 320 MBH Furnace

Ref. Part Part Qty. No. Description Number 248 Gas Valve Body- GV2 400, 500 MBH 041768902 1 640 - 1000 MBH 041768903 1 249 Actuator- VM1 034490100 1 253 Pressure Regulator 400, 500 MBH 034078100 1 640- 1000 MBH 034077804 1 261 Gas Pipe 400, 500 MBH 055964201 1 640, 650 MBH 055964301 790 MBH 055964305 1 800, 1000 MBH 056011102 1

Gas Controls: 400- 1000 MBH FurnaceCanada Approved

Page 129: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 129

Section G- BlowThru Heat SectionOption 4- Gas Heat: Code 04= A

Hi Turn Down Burner: Code 34= ****H*, ****T*, ****U*

Gas Train- Controls: GV1, GV2, GV4, GV5, GV6

790- 1000 MBH Furnaces

Canada Approved (Code 07= CC, CD)

254

254

GV2

400- 650 MBH Furnaces

UL Approved (Code 07= EU, YU)

200- 320 MBH Furnaces

Ref. Part Part Qty. No. Description Number 254 Gas Valve- GV2 073336504 1 N/S Junction Box 020766100 1 N/S Junction Box Cover 000127300 1

Gas Controls: 200, 250, 320 MBH Furnace

Ref. Part Part Qty. No. Description Number 254 Gas Valve- GV1, GV4 400- 650 MBH 073336504 2 Gas Valve- GV1,GV4,GV5 790- 1000 MBH 073336504 3

Gas Controls: 400- 1000 MBH FurnaceUL Approved

Ref. Part Part Qty. No. Description Number 246 Gas Valve Body- GV2 400, 500 MBH 041768902 1 640- 1000 MBH 041768903 1 247 Actuator- GV2 111047401 1 254 Gas Valve- GV4, GV5 400- 650 MBH 073336504 2 Gas Valve- GV4,GV5,GV6 790- 1000 MBH 073336504 3

Gas Controls: 400- 1000 MBH FurnaceCanada Approved

N/S= Not shown on diagram.

GV4

GV1254

GV4GV1

GV5

790- 1000 MBH Furnaces

UL Approved (Code 07= EU, YU)

400- 650 MBH Furnaces

Canada Approved (Code 07= CC, CD)

GV5

GV4

GV2247

246

254

254

246

254

GV5 GV4

GV6

GV2247

254254

Page 130: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 130

Section G- BlowThru Heat SectionOption 4- Gas Heat: Code 04= A

Gas Train- Outlet

275

283

400- 1000 MBH277

283200- 320 MBH

Ref. Part Part Qty. No. Description Number 275 Pipe w/ Valve Mount 200- 320 MBH 035019700 1 400 MBH 046674500 1 500 MBH 035019800 1 640- 1000 MBH 036235500 1 277 Butterfly Valve 200- 320 MBH 034488302 1 400, 500 MBH 034488303 1 640- 1000 MBH 034488304 1 283 Shutoff Valve 200- 320 MBH 059468801 1 400, 500 MBH 059468802 1 640- 800 MBH 059468803 1 1000 MBH Canada 058968804 1 1000 MBH UL 059468803 1

Actuator & Linkage-

See next page

275

275

Hi Turn Down BurnersCode 34= ****H*, ****T*, ****U*

Modulating BurnersCode 34= ****E*, ****R*, ****S*

200- 500 MBH

640- 1000 MBH

Actuator & Linkage- See next page

275 277

Ref. Part Part Qty. No. Description Number 275 Gas Valve 200- 320 MBH 910144815 1 400, 500 MBH 910144816 1 640- 800 MBH 910144817 1

Page 131: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 131

Section G- BlowThru Heat SectionOption 4- Gas Heat: Code 04= A

Gas Train- Damper LinkageModulating Burners w/ VM1 Actuator

Code 34= ****E*, ****R*, ****S*

297

Burner Box

295

311

298

300

310

299

Butterfly Valve (see previous page)

UL UnitsCanada Units (200- 320 MBH)

Canada Units (400- 1000 MBH)

297

Burner Box

295

311

298

300

310

299

Butterfly Valve (see previous page)

301

Canada Actuator Detail

VM1Actuator

Switch KitTransformer

Ref. Part Furnace MBH Qty. No. Description 200- 320 400 500- 650 790- 1000 295 Actuator Motor- VM1 Units w/ MicroTech III Controls USA Units 113157801 113157801 113157801 113157801 1 Canada Units 113157801 0916880022 0916880022 0916880022 1 Units w/ No Temp. Ctl. (Code 12= YC) All Units Before 1/10 0634834221 0634834221 0634834221 0634834221 1 All Units After 1/10 113157801 113157801 113157801 113157801 1 Units w/ No Temp. Ctl. (Code 12= YM) UL Units 111047701 111047701 111047701 111047701 1 Canada Units 111047701 0916880013 0916880013 0916880013 1 297 Crank Arm 034250600 034250600 034250600 034250600 1 298 Ball Joint 034250500 034250500 034250500 034250500 2 299 Linkage Arm 058598401 058598401 058598401 058598401 1 300 Crank Arm 023463200 023463200 023463200 023463200 1 301 Extension Arm (Canada Units Only) Not Used 098735201 098735201 098735201 1 310 Air Damper Lever Arm 058598101 058598101 059365001 058598101 1 311 Gas Valve Arm 058598601 058598601 058598601 058598601 11 Assembly part number. Motor only is p/n 113105101, and Interface Kit only is p/n 067112501.2 Assembly part number. Motor only is p/n 113157801, and Switch Kit only is p/n 060009101.3 Assembly part number. Motor only is p/n 111047701, and Switch Kit only is p/n 060009101.

Page 132: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 132

Section G- BlowThru Heat SectionOption 4- Gas Heat w/ 200MBH and 250 MBH Furnace

Code 04= A AND Code 34= 020***, 025***Cabinet Doors, Gasketing, Hardware, and Flue Box Mounting

051

664665

052

664

665

658

668

667

661

668 667

668

668

Ref. Part Part Qty. No. Description Number 051 Door Assembly 098347015 1 052 Door Assembly 098347020 1 658 Back- Flue Box 403398101 1 661 Flue Box Mount 403399301 1 664 Sleeve Bearing 047138507 6 665 Door Catch 055502602 6 667 Gasket 055921409 4 668 Gasket 055921410 4

Page 133: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 133

Section G- BlowThru Heat SectionOption 4- Gas Heat w/ 320MBH thru 1000 MBH Furnace

Code 04= A AND Code 34= 032***,040***,050***,064***,065***,079***,080***, 100***Cabinet Doors, Gasketing, Hardware, and Flue Box Mounting

Ref. Part Part Qty. No. Description Number 650 Door Assembly 320, 400 MBH 098347021 1 500, 640 MBH 098347022 1 650, 790 MBH 098347023 1 800, 1000 MBH 098347024 1 652 Inspection Door 034095801 1 658 Back- Flue Box 320, 400 MBH 403398001 1 500, 640 MBH 403398401 1 650, 790 MBH 403398601 1 800, 1000 MBH 403398801 1 661 Angle- Flue Box 320, 400 MBH 403399401 1 500, 640 MBH 403399501 1 650, 790 MBH 403399601 1 800, 1000 MBH 403399701 1 663 Drip Shield 033487300 1 664 Sleeve Bearing 047138507 3 665 Door Catch 055502602 3 667 Gasket 055921409 2 668 Gasket 055921410 2 669 Gasket 031949200 1 673 Hinge 034005900 2

650

664665 667

661

658

668669

663

652

Page 134: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 134

Section H- BlowThru Heat Blank Access SectionNotes AND Access Door Latching Assemblies, Key, & Lock

Primary Codes that pertain: 38Additional Codes that pertain: 34, 06

Code 38 determines the section’s characteristics. If Code 38= Y, there is no section. If Code 38= B, F there is a 48” BlowThru Blank/Empty section. If Code 38= E there is a 24” Blank/Empty section. If Code 38= G, H, there is a Straight Attenuator. If Code 38= K, L there is a Straight Attenuator with Tedlar coating. If Code 38= J there is an Elbow Attenuator. If Code 38= M there is an Elbow Attenuator with Tedlar coating.

Code 34 determines the BlowThru Heat Section (Section G). There has to be a Section G in order for there to be a Section H, therefore Code 34 CANNOT= YYYYYY.

Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the BlowThru Heat Blank Access Section, contact Daikin Applied to ensure correct liners, insulation and hardware are ordered.

Ref. Part Part Qty. No. Description Number N/S Sleeve Bearing 047138507 6 N/S Door Catch 055502602 6 N/S Gasket- Horizontal 055921408 1 4 N/S Gasket- Vertical 055921410 4

Door Hardware and Gasketing

N/S= Not Shown on diagram.1 If the unit is split at the fan and heat sections (Code 05= F) use p/n 055921409.

Access Door Latching Assemblies, Key, & Lock (All Sections) 2

Door Latching Assy.Left Hand

Door Latching Assy.Right Hand

01 02

Ref. Part Part Qty. No. Description Number 01 Door Latching Assy.- LH, 73" Section 111242211 var. 02 Door Latching Assy.- RH, 73" Section 111242212 var. 01 Door Latching Assy.- LH, 97” Section 111242221 var. 02 Door Latching Assy.- RH, 97” Section 111242222 var. N/S Access Door Key 021993200 var. N/S Access Door Lock 112031701 var.N/S= Not Shown on diagram.2 These Door Latching Assemblies are used on Standard Unit Section Access Doors.

When replacing a Latch Assembly, first determine the handing of the door. Door handing is dependent upon the door's location on the unit. For Handing identification, refer to the drawings below. If unable to determine the hand of the door, contact Daikin Applied with model and serial information AND the location of the door. Once the door handing is determined, it is then necessary to determine the height of the section. The 73" Latching Assembly is used for unit sections 73 inches high (most sections) and the 97" assembly is used for 97" high sections (eg. Section A2 Energy Recovery [Code 20= *E]).

Page 135: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 135

Ref. Part Part Qty. No. Description Number 84 Light Fixture 042229500 1 85 Bulb- LT16 065492402 1 88 Light Switch- S16 065492201 1 89 Receptacle- REC16 030187000 1

LT16- BT Cooling Section Light/S16- BT Cooling Section Light Switch/REC16-BT Cooling Section Receptacle.84 85

88 89

Section Mounted ControlsLT16, S16, REC16

Section I- BlowThru Cooling SectionNotes

Primary Codes that pertain: 03, 35, 36Additional Codes that pertain: 06

Code 03 determines the Cooling Coil size. If Code 03= S there is a small face area Coil, and if Code 03= L there is a large face area Coil.

Code 35 determines the section characteristics. If Code 35= YYYY, then there is no section. If the first three digits of Code 35= CYY then this is a cooling unit. If the first three digits of Code 35= DYY then the section contains only a Drain Pan in a 48” section. If the first three digits of Code 35= GYY then the unit is cooling with Hot Gas Reheat. If the fourth digit of Code 35= S, the Drain Pan is stainless steel; P, Y in the fourth position indicates that the pan is galvanized steel. If the fourth digit is L, the Drain Pan is wider than standard and made from stainless steel. If the fourth digit of Code 35= T, then the Drain Pan is wider than standard and made from painted galvanized steel. If the fourth digit of Code 35= L, T, the first three digits of Code 35 must be DYY.

Code 36 determines the Cooling Coil characteristics.

Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the BlowThru Cooling Section, contact Daikin Applied to ensure correct liners, insulation and hardware are ordered. For standard Access Door Latching Assemblies, see Section H.

NOTE: See Section D for all parts used in Section I. Although the section location is different within the unit configuration, the components are identical.

Page 136: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 136

Section J- Final Filter SectionNotes

Primary Codes that pertain: 39Additional Codes that pertain: 04, 33 (Mid 2012 & Later), 34

Code 39 determines all of the section characteristics. If Code 39= A, J, B, K, E, L, F, M, G, N, H there are filters; if Code 39= C, D, Q, R, S, T then there is a Blank/Empty Section. If Code 39= Y, there is no section.

Codes 04 and 34 determine what type of heat the unit uses. The type of heat influences the filter media and associated parts.

Code 33 (Mid 2012 & Later) indicates the presence of Magnehelic/Differential Pressure Gauges. See Section B (Filter Section) for Gauge part number and description.

Ref. Part Part Qty. No. Description Number N/S Sleeve Bearing 047138507 6 N/S Door Catch 055502602 6 N/S Gasket- Horizontal 055921408 1 4 N/S Gasket- Vertical 055921410 2

Door Hardware and Gasketing

N/S= Not Shown on diagram.1 If the unit is split at the fan and heat sections (Code 05= F) use p/n 055921409.

387

386

Unit AirFlow

Ref. Part Part Qty. No. Description Number 386 Stat Support 058379401 1 387 HL23 Firestat 047938804 1

Control HL23 Gas Heat Hi-Limit (Firestat)

Gas Hi Limit Control Clogged Filter Control

Ref. Part Part Qty. No. Description Number 345 PC6 Pressure Ctl 065493801 1

UnitBase

345

Supplied with PC6 Harness from Main/Split Box

Section Mounted ControlsHL23 Gas Hi Limit Control: Code 04= A AND Code 39= DOES NOT= YPC6 Clogged Filter Control: Code 39= DOES NOT= Y, C, Q, D, R, S, T

Page 137: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 137

Section J- Final Filter SectionFilters

Flat Filter Rack- Code 39= A, E, J, G, N

Ref. Part Code Code Part Qty. No. Description 04= 39 = Number 4 Filter- 95% Eff- Cartridge, 24 x 24 x 12” High Heat A, E A, J 073381102 8 Filter- 95% Eff- Cartridge, 24 x 24 x 12” Standard S, W A, J 065810702 8 Filter- 95% Eff- Cartridge w/ Intersept, 24 x 24 x 12” ALL ALL E, L 1 8 Filter- 95% Eff- HEPA Cartridge, 24 x 24 x 12” ALL ALL G, N 1 8 4A Gasket- Filter High Heat A, E ALL 073337024 8 Gasket- Filter Standard S, W ALL 021768924 8 5 Filter- 95% Eff- Cartridge, 12 x 24 x 12” High Heat A, E A, J 073381101 4 Filter- 95% Eff- Cartridge, 12 x 24 x 12” Standard S, W A, J 065810701 4 Filter- 95% Eff- Cartridge w/ Intersept, 12 x 24 x 12” ALL ALL E, L 1 4 Filter- 95% Eff- HEPA Cartridge, 12 x 24 x 12” ALL ALL G, N 1 4 5A Gasket- Filter High Heat A, E ALL 073337012 4 Gasket- Filter Standard S, W ALL 021768912 4

4

5

4A

5A

1 Contact Daikin Applied with model and serial number information so that the correct Filter(s) can be identified.

Page 138: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 138

Staggered Filter Rack- Code 39= B, F, K, M

14 14A

14 14A

Section J- Final Filter SectionFilters, Continued

Ref. Part Code Code Part Qty. No. Description 04= 39 = Number 14 Filter- 95% Eff- Cartridge, 24 x 24 x 12” High Heat A, E B, K 073381102 8 Filter- 95% Eff- Cartridge, 24 x 24 x 12” Standard S, W B, K 065810702 8 Filter- 95% Eff- Cartridge w/ Intersept, 24 x 24 x 12” ALL ALL F, M 1 8 14A Gasket- Filter High Heat A, E B, K 073337024 8 Gasket- Filter Standard S, W B 021768924 8 15 Filter- 95% Eff- Cartridge, 12 x 24 x 12” High Heat A, E B, K 073381101 8 Filter- 95% Eff- Cartridge, 12 x 24 x 12” Standard S, W B, K 065810701 8 Filter- 95% Eff- Cartridge w/ Intersept, 12 x 24 x 12” ALL ALL F, M 1 8 15A Gasket- Filter High Heat A, E B, K 073337012 8 Gasket- Filter Standard S, W B, K 021768912 81 Contact Daikin Applied with model and serial number information so that the correct Filter(s) can be identified.

15 15A

Page 139: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 139

Section K- Discharge Plenum Section- RPS OR RFSNotes

Primary Codes that pertain: 40Additional Codes that pertain: 6, 11, 16, 34, 35, 36, 38, 39, 41.

Code 40 determines the discharge direction. RPS, RFS units may have bottom discharge (Code BE, BY) OR side discharge (Code LY, RY, SY). RFS units may also have front discharge (Code FY). The VAV Damper option is Code *E.

Code 06, insulation and liners, influences the front panels part numbers. For sheet metal components that make up the Discharge Plenum Section, contact Daikin Applied to ensure correct liners, insulation and hardware are ordered. For standard Access Door Latching Assemblies, see Section H.

Code 11, Disconnect Switch option, influences Access Door part numbers.

Code 16 determines Smoke Detectors. If Code 16= 2, 3 there is a Supply Air Smoke Detector (SD1). For RPS and RFS units with heat the SD1 is in Section K. For RDT units, OR RPS, RFS DrawThru cooling only units (units with no separate discharge plenum section) SD1 is in the Supply Air section (Section F).

Codes 34- 39, the BlowThru/Final Filter section codes, and Code 41, the special Blank/Empty Section code, pertain to some of the final assembly part numbers. If there is no BlowThru final section then the Discharge Plenum is attached directly to the Supply Air Section and some of the final assembly part numbers are different than they are if the BlowThru section is present. If Code 41= Y (no Blank Access Compartment), then the Discharge Plenum end panels are painted. If the Blank/Empty Section is present then the end panels are unpainted.

Note: The RPS and RFS Main Control Box is located in the Discharge Plenum Section. However, Main Control Box components are listed in Section N.

50

51

Ref. Part Part Qty. No. Description Number 50 Smoke Detector- SD1 098873101 1 51 Sensing Tube 049025002 1

Smoke Detector- SD1

Section Mounted ControlsOAT, DAT, SD1

Ref. Part Part Qty. No. Description Number 7 OA Temp. Sensor- OAT 193414602 1 8 DA Temp. Sensor- DAT 193414602 1

Discharge Air Temperature Sensor- DAT &Outdoor Air Temperature Sensor- OAT7 8

OAT DAT

Smoke Detector

Detail

Page 140: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 140

Section K- Discharge Plenum SectionDischarge Damper Assembly- w/ Actuator ACT5

Code 40= BE

ACT5 Actuator Linkage Detail

15

23

20

3

1917

26

424

16

1821

2215

22

Ref. Part Part Number Qty. No. Description C40= BE Complete Damper Assy. w/ Actuator 403716304 1 3 Motor Mount 055921201 1 4 Blade 055921302 9 15 Angle- Linkage 055917702 3 16 Blade- Angle 055638102 27 17 Shaft- Damper 055637801 18 18 Linkage- Shaft 055536601 1 19 Bearing, Flange- Damper 001113500 18 20 Actuator, 24V ACT5 113144901 1 21 Crank Arm 403717101 1 22 Ball Joint 000887000 2 23 Bearing- Sleeve 047138507 27 24 Gasket 030051985 10 25 Support- Actuator 403716801 1 26 Retainer- Actuator 403717301 1 27 Bearing- Sleeve 047138504 1

NOTE: This Discharge Damper and ACT5 Actuator assembly may also be located in Section F (Supply Air). The Discharge Air opening is in the Supply Air section on RDT units, and RPS OR RFS DrawThru units with no BlowThru heat (applications where Section F is attached directly to the condensing unit, OR is the end of the unit).

27

25

21

20

Page 141: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 141

Section L- Out-of-Airstream Blank Access SectionNotes

Primary Codes that pertain: 41

If Code 41= Y, there is no Blank/Empty Section. If Code 41= 1, there is a 48/24” Blank/Empty Section with Access Doors and Light (LT20). When Code 41= 2, there is a 48” Blank/Empty Section with Access Doors and Light (LT20).

For sheet metal components that make up the Out-of-Airstream Blank Access Section, contact Daikin Applied to ensure correct liners, insulation and hardware are ordered. For standard Access Door Latching Assemblies, see Section H.

This Blank/Empty Access section may be installed on an RPS OR an RFS unit.

Ref. Part Section Size No. Description 48” (C41= 1) Qty. 48/24” (C41= 2) Qty. N/S Door Assembly 060056005 2 060056005 2 060056002 2 N/S Gasket- Horizontal 055921409 4 055921409 4 055921408 4 N/S Gasket- Vertical 055921410 4 055921410 8 N/S Door Sleeve Bearing 047138507 6 047138507 12 N/S Door Catch 055502602 6 055502602 12

Doors, Gasketing and Hardware

N/S= Not Shown on diagram.

Ref. Part Part Qty. No. Description Number 284 Light Fixture 042229500 1 285 Bulb- LT20 065492402 1 288 Light Switch- S20 065492201 1 289 Receptacle- REC20 030187000 1

LT20- Blank Access Section Light/S20- Blank Access Section Light Switch/REC20- Blank Access Section Receptacle284 285

288 289

Section Mounted ControlsLT20, REC20, S20- Section Mounted Light

Page 142: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 142

Section M- Condenser SectionNotes

Primary Codes that pertain: 09, 12, 43, 44, 47, 54, 68Additional Codes that pertain: 17, 18, 42, 45

This section houses the Compressors, Condenser Coils, Condenser Control Box (RCS only), Pressure Controls Box (RPS/RDT only), and Fan Deck. RPS and RDT units do not have a control box in the Condenser section (all condenser controls are in the main unit Control Box).

The Compressor high and low pressure controls as well as the fan pressure controls are always located in this section. RCS units have the pressure controls mounted on the control box Manifold (SpeedTrol Inverters and Line Reactors are in the Control Box). RPS and RDT units have the pressure controls as well as SpeedTrol Inverters and Line Reactors (if supplied) in a box mounted where the air handler and condensing unit attach.

Code 09, unit voltage, affects Compressor Contactors and Motor Protectors (located in the Condenser Control Box for RCS units) as well as the Compressor selection.

Code 12 determines whether there is a MicroTech III Unit Controller present or if the unit is not provided with a factory installed controller.

Code 43 determines if the Micro Channel Condenser Coils have Seal Tite Conduits and/or Coil Guards; and whether the Coils are Electrofin coated.

Code 44 shows the type of compressor selected. Code 44= R NORMALLY stands for units with ALL standard scroll compressors. For units with Inverter Compressors (Code 44= V, W) refer to form 7000513. (Note that RPS, RDT074Ds are inverter compressor only units.) Starting in late 2014, some units are built as specials with digital scroll compressors with Code 44= R AND Code 60= XX with digital scroll compressors listed as a special feature (refer to the drawing below for an example of Special Code String Text). Confirm the presence of a digital compressor BEFORE ordering to ensure that the correct part(s) are identified. Code 44= D also indicates the presence of digital compressors.

Code 47 determines Condenser Fan operation: FanTrol [Standard operation] (Code 47= 1), OR SpeedTrol [Low Ambient operation] (Code 47= 2). If Code 47= 3, the unit is equipped with optional Quiet Fan assemblies and FanTrol. If Code 47= 4, the unit is equipped with optional Quiet Fan assemblies and SpeedTrol.

Page 143: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 143

Section M- Condenser SectionNotes

Code 54 indicates that Modulating Hot Gas Reheat was chosen. This option alters the number of Variable Speed Condenser motors and the Condenser Fan circuiting in the Main Control Box.

Code 68 specifies the SCCR or “Short Circuit Current Rating” for the unit. Standard units are always rated at “10 SCCR” (Code 68= 10, OR no entry). An entry with any other rating (Eg: Code 68= 22, 65 OR indicated in the specials description in the Code String lookup) may change disconnect switches, circuit breakers, fuses, and other miscellaneous components. When control box parts are required for units with nonstandard SCCR ratings, contact Daikin Applied with model and serial number information so that the correct part(s) can be identified.

Code 17 determines whether the RCS control box has Ground Fault and/or Phase Failure capability.

Code 18 determines if there is a unit powered Receptacle, and associated controls.

Code 42 indicates Compressor capacity control.

Code 45 determines the way the Compressor is mounted. If Code 45= Y the unit must be an RFS.

The Condenser Coil Compartment, and the Compressor Compartment components are different for RPS and RCS units. All other aspects of the section (Fan Deck, Compressors, etc.) are identical. The Condenser Section is integral to the RPS unit, but is not Used on the RFS.

An RCS unit is a condensing unit only. RCS units can either be used as a Stand Alone Condenser unit, OR used in conjunction with an RFS. For information specific to RCS Standalone Units (RCS045- 075D units when Code 12= *A), refer to RPL form 7000136. Note that an RCS072D is a Standalone only unit and therefore is not included in this document.

NOTE: This form is to be used for RCS units when Code 12= DOES NOT= *A. For RCS045- 075D units when Code 12= *A refer to form # 7000136.

Page 144: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 144

Section M- Condenser SectionCondenser Fan Deck Assembly

045- 068D Diagrams: Code 47= 1, 2

061, 062, 068D Fan Deck Detail

063D Fan Deck Detail

(063D shown)

112

113

101

113

130

132

131

111

Motor Mount to Fan Panel Mounting Detail

101

125

113

131

121

133

133

Fan Detail

150 55

Fan # 12 Fan # 11

Fan # 22 Fan # 21Fan # 23

Fan # 13

End of Unit

05

Fan # 12Fan # 11

Fan # 22Fan # 21

Fan # 13Fan # 23

End of Unit

045, 050, 060D Fan Deck Detail

CDF150

CDF160

CDF153

MO

TOR

GN

DW

IRE

CDF151

Fan # 12Fan # 11

Fan # 22Fan # 21

End of Unit

Fan Layout Detail

051D Fan Deck Detail

Fan # 12Fan # 11

Fan # 22Fan # 21

End of Unit

End of Unit

Page 145: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 145

Ref. Part Part Unit Size No. Description Number 045 050 051 060 061 062 063 068 Condenser Coils Code 43= M* 5 33.5” x 71” 6/13 & Earlier 258997801 4 4 4 4 4 33.5" x 71" 7/13 thru 5/14 1 4 4 4 4 4 33.5” x 71” 6/14 & Later 910137801 4 4 4 4 4 36” x 84” 6/13 & Earlier 113131401 2 2 36" x 84" 7/13 thru 3/14 1 2 2 36” x 84” 4/14 & Later 910137884 2 2 46” x 84” 6/13 & Earlier 113131301 2 2 46” x 84” 7/13 thru 2/14 1 2 2 46" x 84" 3/14 & Later 910137886 2 2 Condenser Coils Code 43= T* 5 33.5” x 71” 910152744 4 4 4 4 4 4 36” x 84” 910152750 2 2 46” x 84” 910152752 2 2 Condenser Coils, Coated Code 43= P* 5 33.5” x 71” 6/13 & Earlier 258997802 4 4 4 4 4 33.5” x 71” 7/13 thru 5/14 1 4 4 4 4 4 33.5” x 71” 1/14 & Later 910137802 4 4 4 4 4 36” x 84” 9/13 & Earlier 113131402 2 2 36” x 84” 10/13 thru 1/14 1 2 2 36” x 84” 2/14 & Later 910137885 2 2 46” x 84” 9/13 & Earlier 113131302 2 2 46” x 84” 10/13 thru 1/14 1 2 2 46” x 84” 2/14 & Later 910137887 2 2 Condenser Coils, Coated Code 43= U* 5 33.5” x 71” 910152745 4 4 4 4 4 4 36” x 84” 910152751 2 2 46” x 84” 910152753 2 2 111 Condenser Fan Motor FanTrol/SpeedTrol 208/230/460V 500552601 2 4 4 4 4 6 6 6 6 FanTrol/SpeedTrol 575V 046744203 4 4 4 4 6 6 6 6 Condenser Fan Deck Code 47= 1, 2 55 Panel- Blank 258933501 2 2 5 2 3 101 Top Panel 258929501 4 4 4 4 6 6 6 6 112 Fan Propeller 258981901 4 4 4 4 6 6 6 6 113 Motor Mount 098667802 3 8 8 8 8 12 12 12 12 121 Grommet 000898500 16 16 16 16 24 24 24 24 125 Spacer- Steel 030434500 16 16 16 16 24 24 24 24 130 Screw- Cap 048878129 16 16 16 16 24 24 24 24 131 Nut- Lock 040500104 32 32 32 32 48 48 48 48 132 Washer, Narrow- Plain 040500307 16 16 16 16 24 24 24 24 133 Washer, Wide- Plain 041542301 32 32 32 32 48 48 48 48 150 Fan Guard 098668302 4 4 4 4 6 6 6 6 N/S Vandal Guard Kit (RPS/RDT) 403909504 1 1 1 1 1 N/S Vandal Guard Kit (RPS/RDT) 403909506 1 1 1 N/S Vandal Guard Kit (RCS) 403909514 1 1 1 1 1

Section M- Condenser SectionCondenser Fan Deck Assembly

045- 068D Components

N/S= Not shown on Diagram.1 Due to production overlap, contact Daikin Applied with model and serial number information to ensure that the correct coil is identified.2 The original FanTrol motor (Code 47= 1) is obsolete and no longer available. Use inverter duty motor 500552601 for ALL applications when

Code 47= 1 OR 2.3 This is only one of two pieces that make up the Motor mount. For a complete Motor Mount, order a quantity of TWO per Motor. Quantity listed

is the TOTAL for the unit.

Page 146: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 146

55

(075, 079D shown)

150

075, 079D Fan Deck Detail

070, 071D Fan Deck Detail

Section M- Condenser SectionCondenser Fan Deck Assembly

070- 079D Diagrams: Code 47= 1, 2

112

113

101

113

130

132

131

111

Fan Detail Motor Mount to Fan Panel Mounting Detail

101

125

113

131

121

133

133

Fan Layout Detail

End of Unit

Fan # 12 Fan # 11

Fan # 22 Fan # 21Fan # 23

Fan # 13

End of Unit

Fan # 12Fan # 11 Fan # 13

Fan # 22Fan # 21 Fan # 23

Fan # 14Fan # 24

End of Unit

5

Page 147: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 147

Section M- Condenser SectionCondenser Fan Deck Assembly

070D- 079D Components: Code 47= 1, 2

Ref. Part Part Unit Size No. Description Number 070 071 075 079 Condenser Coils Code 43= M* 5 32” x 84” 6/13 & Earlier 258957001 4 4 32” x 84” 7/13 thru 5/14 1 4 4 32” x 84” 6/14 & Later 910137909 4 4 36” x 84” 6/13 & Earlier 113131401 2 2 36” x 84” 7/13 thru 3/14 1 2 2 36” x 84” 4/14 & Later 910137884 2 2 46” x 84” 6/13 & Earlier 113131301 2 2 46” x 84” 7/13 thru 2/14 1 2 2 46” x 84” 3/14 & Later 910137886 2 2 Condenser Coils Code 43= T* 5 36” x 84” 910152750 2 2 46” x 84” 910152752 2 2 Condenser Coils, Coated Code 43= P* 32” x 84” 7/13 & Earlier 258957002 4 4 32” x 84” 8/13 thru 1/14 1 4 4 32” x 84” 2/14 & Later 910137910 4 4 36” x 84” 9/13 & Earlier 113131402 2 2 36” x 84” 10/13 thru 1/14 1 2 2 36” x 84” 2/14 & Later 910137885 2 2 46” x 84” 9/13 & Earlier 113131302 2 2 46” x 84” 10/13 thru 1/14 1 2 2 46” x 84” 2/14 & Later 910137887 2 2 Condenser Coils, Coated Code 43= U* 5 36” x 84” 910152751 2 2 46” x 84” 910152753 2 2 111 Condenser Fan Motor FanTrol/SpeedTrol 208/230/460V 500552601 2 6 6 8 8 FanTrol/SpeedTrol 575V 046744203 6 6 8 8 Condenser Fan Deck Code 47= 1, 2 55 Panel- Blank 258933501 3 3 1 1 101 Top Panel 258929501 6 6 8 8 112 Fan Propeller 258981901 6 6 8 8 113 Motor Mount 098667802 3 12 12 16 16 121 Grommet 000898500 24 24 32 32 125 Spacer- Steel 030434500 24 24 32 32 130 Screw- Cap 048878129 24 24 32 32 131 Nut- Lock 040500104 48 48 64 64 132 Washer, Narrow- Plain 040500307 24 24 32 32 133 Washer, Wide- Plain 041542301 48 48 32 64 150 Fan Guard 098668302 6 6 8 8 N/S Vandal Guard Kit (RPS/RDT) 403909505 1 1 N/S Vandal Guard Kit (RPS/RDT) 403909506 1 1 N/S Vandal Guard Kit (RCS) 403909515 1 1 N/S= Not shown on Diagram.1 Due to production overlap, contact Daikin Applied with model and serial number information to ensure that the correct coil is

identified.2 The original FanTrol motor (Code 47= 1) is obsolete and no longer available. Use inverter duty motor 500552601 for ALL

applications when Code 47= 1 OR 2.3 This is only one of two pieces that make up the Motor mount. For a complete Motor Mount, order a quantity of TWO per Motor.

Quantity listed is the TOTAL for the unit.

Page 148: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 148

Section M- Condenser SectionQuiet Fan Assembly

Code 47= 3, 4

11

Unit Size Ref. Part Part No. Description Number 045 050 051 060 061 062 063 068 070 071 075 079 1 Quiet Fan Assy. 1 208V 500526602 4 4 4 4 6 6 6 6 6 6 8 8 230V 500526603 4 4 4 4 6 6 6 6 6 6 8 8 460V 500526604 4 4 4 4 6 6 6 6 6 6 8 8 575V 500526605 4 4 4 4 6 6 6 6 6 6 8 8 55 Panel, Blank 258933501 2 2 5 2 NA NA 3 NA 3 3 1 11 Quiet Fan Assemblies are sold as assemblies ONLY. Individual components including the Motor, Fan Prop, Fan Guard, Motor

Mount, and Fan Top Panel are NOT available separately.

Page 149: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 149

Size 045

Ref. Part Part No. Description Number 1, 2 Compressors (8/14 & Earlier) 300046083 1 4 Compressors (7/14 & Earlier) 300046085 1 4 Compressors (5/15 & Earlier) 300046087 1 4 145 Heater- Crankcase (for early compressors) 112056401 4 4 4 1, 2 Compressors (5/15 & Later) 500597501 1 4 Compressors (1/17 & Later) 500597502 1 4 Compressors (6/15 & Later) 500597504 1 4 145 Heater- Crankcase (for later compressors) 112056402 4 4 4 102 Grommet 251774401 12 12 12 103 Sleeve 111056201 12 12 12 105 Screw 046093822 12 12 12 106 Washer- Plain 040500316 12 12 12 107 Washer- Lock 048164812 12 12 12 125 Junction Box- Compressor 500429201 4 4 4 155 Screw- Junction Box 046093802 16 16 16 165 Gasket- Junction Box 019647500 2 2 2

208/

230V

460V

575V

Side View Compressor Rail to Base Channel Mounting Detail

(6 places)

102

107 105106

103

Compressor Rail

Compressor Mounting Channel

Section M- Condenser SectionCondenser Fan Deck Assembly

Standard Compressors & Compressor ComponentsUnit Size 045D: Code 44= R OR D 3

NOTE: Quantities listed are for the unit.1 Compressors are factory mounted in Tandem assemblies, but replacement Compressors are available as SINGLE

compressors ONLY. A Tandem compressor is two compressors piped together in one assembly. There are two tandems per unit (one on each circuit). When replacing a single compressor out of a Tandem assembly, the original piping is reused. For units built during the transition, contact Daikin Applied with model and serial number information to ensure that the correct compressor is identified.

2 4 feet per junction box.3 Note that there are some Digital Scroll Compressor units built as specials (Code 44= R AND Code 60= XX)

WITH Digital Scroll compressors listed as a special feature (refer to the Notes at the beginning of this section for more information). Digital Compressors are ALWAYS located in Circuit # 2. For these units refer to the “Digital Compressors & Components” page at the end of this section.

Standard Cmpr. Units Circuit # 1 & 2 AND Digital Scroll Cmpr. Units: Circuit #1 3

1

125155

165

145 145

125

155165

2or

Page 150: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 150

Size 050, 051

Ref. Part Part No. Description Number 1, 2 Compressors 300046089 1 4 Compressors 300046091 1 4 Compressors 300046093 1 4 102 Grommet 251774401 12 12 12 103 Sleeve 111056201 12 12 12 105 Screw 046093822 12 12 12 106 Washer- Plain 040500316 12 12 12 107 Washer- Lock 048164812 12 12 12 125 Junction Box- Compressor 500429201 4 4 4 145 Heater- Crankcase 112056401 4 4 4 155 Screw- Junction Box 046093802 16 16 16 165 Gasket- Junction Box 019647500 2 2 2

208/

230V

460V

575V

1

125

Side View Compressor Rail to Base Channel Mounting Detail

(6 places)

102

107 105106

103

Compressor Rail

Compressor Mounting Channel

155

165

145 145

125

155165

Section M- Condenser SectionCondenser Fan Deck Assembly

Standard Compressors & Compressor ComponentsUnit Size 050, 051D: Code 44= R OR D 3

NOTE: Quantities listed are for the unit.1 Compressors are factory mounted in Tandem assemblies, but replacement Compressors are available as SINGLE

compressors ONLY. A Tandem compressor is two compressors piped together in one assembly. There are two tandems per unit (one on each circuit). When replacing a single compressor out of a Tandem assembly, the original piping is reused.

2 4 feet per junction box.3 Note that there are some Digital Scroll Compressor units built as specials (Code 44= R AND Code 60= XX)

WITH Digital Scroll compressors listed as a special feature (refer to the Notes at the beginning of this section for more information). Digital Compressors are ALWAYS located in Circuit # 2. For these units refer to the “Digital Compressors & Components” page at the end of this section.

2or

Standard Cmpr. Units Circuit # 1 & 2 AND Digital Scroll Cmpr. Units: Circuit #1 3

Page 151: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 151

Section M- Condenser SectionCondenser Fan Deck Assembly

Standard Compressors & Compressor ComponentsUnit Size 060- 063D: Code 44= R OR D 2

21 or

Side View Compressor Rail to Base Channel Mounting Detail

(6 places)

102

107 105106

103

Compressor Rail

Compressor Mounting Channel

145 145

Unit Size 060 3 061 062 3 063

Ref. Part Part No. Description Number 1, 2 Compressors 4/14 & Earlier 113091901 1 4 4 4 Compressors 5/14 & Later 404152401 1 4 4 4 Compressors 4/14 & Earlier 113091902 1 4 4 4 Compressors 5/14 & Later 404152402 1 4 4 4 Compressors 4/14 & Earlier 113091904 1 4 4 4 Compressors 5/14 & Later 404152404 1 4 4 4 102 Grommet 251774401 12 12 12 12 12 12 12 12 12 12 12 12 103 Sleeve 111056201 12 12 12 12 12 12 12 12 12 12 12 12 105 Screw 046093822 12 12 12 12 12 12 12 12 12 12 12 12 106 Washer- Plain 040500316 12 12 12 12 12 12 12 12 12 12 12 12 107 Washer- Lock 048164812 12 12 12 12 12 12 12 12 12 12 12 12 145 Heater- Crankcase 113108903 4 4 4 4 4 4 4 4 4 4 4 4

208/

230V

460V

575V

208/

230V

460V

575V

208/

230V

460V

575V

208/

230V

460V

575V

NOTE: Quantities listed are for the unit.1 Compressors are factory mounted in Tandem assemblies, but replacement Compressors are available as SINGLE compressors ONLY.

A Tandem compressor is two compressors piped together in one assembly. There are two tandems per unit (one on each circuit). When replacing a single compressor out of a Tandem assembly, the original piping is reused.

2 Note that there are some Digital Scroll Compressor units built as specials (Code 44= R AND Code 60= XX) WITH Digital Scroll compressors listed as a special feature (refer to the Notes at the beginning of this section for more information). Digital Compressors are ALWAYS located in Circuit # 2. For these units refer to the “Digital Compressors & Components” page at the end of this section.

3 Unit sizes no longer in production as of 2015.

Standard Cmpr. Units Circuit # 1 & 2 AND Digital Scroll Cmpr. Units: Circuit #1 3

Page 152: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 152

Section M- Condenser SectionCondenser Fan Deck Assembly

Standard Compressors & Compressor ComponentsUnit Size 068D: Code 44= R OR D 3

Size 068

Ref. Part Part No. Description Number 1, 2 Compressors 4/14 & Earlier 113092501 1 4 Compressors 5/14 & Later 404152501 1 4 Compressors 4/14 & Earlier 113092502 1 4 Compressors 5/14 & Later 404152502 1 4 Compressors 4/14 & Earlier 113092504 1 4 Compressors 5/14 & Later 404152504 1 4 102 Grommet 251774401 12 12 12 103 Sleeve 111056201 12 12 12 105 Screw 046093822 12 12 12 106 Washer- Plain 040500316 12 12 12 107 Washer- Lock 048164812 12 12 12 145 Heater- Crankcase 113108903 4 4 4

208/

230V

460V

575V

Side View Compressor Rail to Base Channel Mounting Detail

(6 places)

102

107 106

103

Compressor Rail

Compressor Mounting Channel

NOTE: Quantities listed are for the unit.1 Compressors are factory mounted in Tandem assemblies, but replacement Compressors are available as SINGLE

compressors ONLY. A Tandem compressor is two compressors piped together in one assembly. There are two tandems per unit (one on each circuit). When replacing a single compressor out of a Tandem assembly, the original piping is reused.

2 Note that there are some Digital Scroll Compressor units built as specials (Code 44= R AND Code 60= XX) WITH Digital Scroll compressors listed as a special feature (refer to the Notes at the beginning of this section for more information). Digital Compressors are ALWAYS located in Circuit # 2. For these units refer to the “Digital Compressors & Components” page at the end of this section.

Standard Cmpr. Units Circuit # 1 & 2 AND Digital Scroll Cmpr. Units: Circuit #1 3

21 or145 145

Page 153: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 153

Section M- Condenser SectionCondenser Fan Deck Assembly- Compressors & Compressor Components

Unit Size 070- 079D: Code 44= R 1, 3

Unit Size 070, 071 075 079

Ref. Part Part No. Description Number 1, 2 Compressors- Circuits #1, 2 113091101 6 Compressors- Circuits #1, 2 113091102 6 Compressors- Circuits #1, 2 113091104 6 Compressors- Circuits #1, 2 070-075, Circuit #1 079D 113091301 6 3 Compressors- Circuits #1, 2 070-075, Circuit #1 079D 113091302 6 3 Compressors- Circuits #1, 2 070-075, Circuit #1 079D 113091304 6 3 Compressors- Circuit #2 4/14 & Earlier 113091901 3 Compressors- Circuit #2 5/14 & Later 404152401 3 Compressors- Circuit #2 4/14 & Earlier 113091902 3 Compressors- Circuit #2 5/14 & Later 404152402 3 Compressors- Circuit #2 4/14 & Earlier 113091904 3 Compressors- Circuit #2 5/14 & Later 404152404 3 102 Grommet 251774401 16 16 16 16 16 16 16 16 16 103 Sleeve 111056201 16 16 16 16 16 16 16 16 16 105 Screw 046093822 16 16 16 16 16 16 16 16 16 106 Washer- Plain 040500316 16 16 16 16 16 16 16 16 16 107 Washer- Lock 048164812 16 16 16 16 16 16 16 16 16 120 Sight Glass- Gas Line 015997806 2 2 2 2 2 2 2 2 2 125 Junction Box- Compressor 500429201 6 6 6 6 6 6 6 6 6 130 Fitting- Rotolock 113129601 6 6 6 6 6 6 6 6 6 145 Heater- Crankcase 112056401 6 6 6 6 6 6 6 6 6 155 Screw- Junction Box 046093802 24 24 24 24 24 24 24 24 24 165 Gasket- Junction Box 019647500 2 2 2 2 2 2 2 2 2

175 Rail- Trio Compressor Mounting 258931401 4 4 4 4 4 4 4 4 4 176 Spacer 258932401 24 24 24 24 24 24 24 24 24 177 Screw 046093824 24 24 24 24 24 24 24 24 24 179 Washer 040500316 24 24 24 24 24 24 24 24 24

208/

230V

460V

575V

208/

230V

460V

575V

208/

230V

460V

575V

Discharge Tubing

Gas Tubing Suction Tubing

Comp. #6Comp. #4Comp. #2

Comp. #1 Comp. #3 Comp. #5or or or

Circuit #1

Circuit #2or

2

1or

1 Quantities are for the unit. Each circuit has equal quantities of each part.2 6 feet per junction box.3 Note that Unit Size RPS/RDT074D uses Inverter Compressors only. Refer to form 7000513.

145

Side View Top View

175

120

125165

Comp. #6Comp. #4Comp. #2

Comp. #1 Comp. #3 Comp. #5or or or

Circuit #1

Circuit #2or

Compressor Rail to Base Channel Mounting Detail

(8 places)

102

107 105106

103

Compressor Rail

Compressor Mounting Channel

Compressor to Compressor Rail Mounting Detail

176177179 175

130

155

Page 154: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 154

Unit Size 045 050, 051 061, 063 068

Ref. Part No. Number N/S 500597001 2 1 500597002 2 1 500597101 2 1 500597102 2 1 500597201 2 1 500597202 2 1 500597301 2 1 500597302 2 1 3 1 1 1 1

Section M- Condenser Section Digital Compressors & Components, Circuit #2

Code 44= R AND Code 60= XX OR Code 44= D 1, 3

Digital Scroll Compressor Units: Circuit #2 1

208/

230V

460V

575V

208/

230V

460V

575V

208/

230V

460V

575V

208/

230V

460V

575V

Part Number Unit Unit Compressor Compressor Compressor Compressor Size Voltage 1 2 3 4 045 All N/A 112056401 N/A N/A 050 All N/A 112056401 N/A N/A 051 All N/A 112056401 N/A N/A 061 All N/A 113108903 N/A N/A 063 All N/A 113108903 N/A N/A 068 All N/A 113108903 N/A N/A

Digital Scroll Compressor Units Crankcase Heaters 4

N/A= Not available.4 One Crankcase heater is used per compressor.

N/S= Not shown on diagram.1 There are some Digital Scroll Compressor units built as specials (Code 44= R AND Code 60=

XX) WITH Digital Scroll compressors listed as a special feature (refer to the Notes page at the beginning of this section for more information). Digital Compressors are ALWAYS located in Circuit # 2.

2 Compressors are factory mounted in TANDEM assemblies, but REPLACEMENT COMPRESSORS ARE AVAILABLE AS SINGLE COMPRESSORS ONLY as shown above. A Tandem compressor is two compressors piped together in one assembly. There are two tandems per unit. When replacing a single compressor out of a Tandem assembly, the original piping is reused.

3 For unit sizes/voltages not shown contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified.

Page 155: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 155

Condenser SectionDigital Compressors & Components, Circuit #2, Unit Size 045D- 068D:

Code 44= R AND Code 60= XX OR Code 44= D 1

Digital Compressor Detail Compressor Rail to Base Channel Mounting Detail

245

03

Unit Size 3

045 050, 051 061, 063 068

Ref. Part Part No. Description Number 01 Compressor- Digital, Circuit # 2 500597001 2 1 Compressor- Digital, Circuit # 2 500597002 2 1 Compressor- Digital, Circuit # 2 500597101 2 1 Compressor- Digital, Circuit # 2 500597102 2 1 Compressor- Digital, Circuit # 2 500597201 2 1 Compressor- Digital, Circuit # 2 500597202 2 1 Compressor- Digital, Circuit # 2 500597301 2 1 Compressor- Digital, Circuit # 2 500597302 2 1 Compressor- Digital, Circuit # 2 3 1 1 1 1 02 Thermistor- Discharge (CDT) 910139660 1 1 1 1 1 1 1 1 1 1 1 1 03 Compressor Mounting Kit 300000462 1 1 1 1 1 1 1 1 1 1 1 1 245 Heater- Crankcase 112056401 4 4 4 4 4 4 Heater- Crankcase 113108903 4 4 4 4 4 4 202 Kit- Unloader Coil, 120V (SV7) 910139659 1 1 1 1 1 1 1 1 1 1 1 1

208/

230V

460V

575V

208/

230V

460V

575V

208/

230V

460V

575V

208/

230V

460V

575V

NOTE: Quantities listed are for the unit.1 There are some Digital Scroll Compressor units built as specials (Code 44= R AND Code 60= XX) WITH Digital Scroll

compressors listed as a special feature (refer to the Notes page at the beginning of this section for more information). Digital Compressors are ALWAYS located in Circuit # 2.

2 Compressors are factory mounted in TANDEM assemblies, but REPLACEMENT COMPRESSORS ARE AVAILABLE AS SINGLE COMPRESSORS ONLY as shown above. A Tandem compressor is two compressors piped together in one assembly. There are two tandems per unit. When replacing a single compressor out of a Tandem assembly, the original piping is reused.

3 For unit sizes/voltages not shown contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified.

01

20202

03

Page 156: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 156

138 139 138 137

135

138 134

135

138 134

Circuit # 2 Circuit # 1

Ref. Sch. Part Part Qty. No. Sym. Description Number 134 LP1, 2 Switch- Low Pressure FanTrol Unit Code 47= 1, 3 403585101 2 SpeedTrol Unit Code 47= 2, 4 910139364 1 2 135 HP1, 2 Switch- High Pressure 403585001 2 137 SPTRL Switch- SpeedTrol Pressure Code 47= 2, 4 403586901 2 Harness- Switch SpeedTrol Pressure 403586601 2 138 Valve Core 026541100 10 139 Valve Cap FanTrol Unit Code 47= 1, 3 032943500 8 SpeedTrol Unit Code 47= 2, 4 032943500 6

SpeedTrol(Code 47= 2, 4)

FanTrol(Code 47= 1, 3)

SpeedTrol(Code 47= 2, 4)

FanTrol(Code 47= 1, 3)

138 139 138 139

138 134

135

138 139138 137

135

138 134

Section M- Condenser SectionRCS Pressure Manifolds- 045D- 068D

HP1, HP2, LP1, LP2, SPTRL

SPTRLSPTRL

HP1HP2

LP1LP2

HP1HP2

LP1LP2

1 This Pressure Switch replaces a Switch with a lower pressure rating. P/N 910139364 has the currently recommended pressure ratings.

Page 157: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 157

Section M- Condenser SectionRCS Pressure Manifolds- 070- 079D

PC13, PC23, HP1, HP2, LP1, LP2, SPTRL

138 139138 137

138 136

135

138 134

138 139 139 138

138 136

135

138 134

138 139138 137

138 136

135

138 134

138 139139 138

138 136

135

138 134

Circuit # 2 Circuit # 1

Ref. Sch. Part Part Qty. No. Sym. Description Number 134 LP1, 2 Switch- Low Pressure FanTrol Unit Code 47= 1, 3 403585101 2 SpeedTrol Unit Code 47= 2, 4 910139364 1 2 135 HP1, 2 Switch- High Pressure 403585001 2 136 PC13, 23 Switch- Fan Pressure 403585601 2 137 SPTRL Switch- SpeedTrol Pressure Code 47= 2, 4 403586901 2 Harness- Switch SpeedTrol Pressure 403586601 2 138 Valve Core 026541100 10 139 Valve Cap FanTrol Unit Code 47= 1, 3 032943500 6 SpeedTrol Unit Code 47= 2, 4 032943500 4

SpeedTrol(Code 47= 2, 4)

FanTrol(Code 47= 1, 3)

SpeedTrol(Code 47= 2, 4)

FanTrol(Code 47= 1, 3)

SPTRLSPTRL

HP1HP2

LP1LP2

HP1HP2

LP1LP2

PC23

PC23

PC23

PC23

1 This Pressure Switch replaces a Switch with a lower pressure rating. P/N 910139364 has the currently recommended pressure ratings.

Page 158: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 158

Section M- Condenser SectionRPS/RDT Pressure Controls Box- 045D- 068D: (03/2013 & Earlier)

AFD11, AFD21, LR11, LR21, LP1, LP2, HP1, HP2, TC12, TC14

(Note: For RCS units, the SpeedTrol Inverters— AFD11, AFD21— and Line Reactors— [575V only]— are located in the RCS control box, and the pressure controls for the compressor and FanTrol are located on the control box manifolds.)

237

AFD11 AFD21

LR11 LR21

SPTRL

SPTRL

HP1

HP2

LP1

LP2237

235

234234

235

244

246

238 239 typ.

238

238238

238

Ref. Sch. Part Part Qty. No. Sym. Description Number 234 LP1, 2 Switch- Low Pressure FanTrol Unit Code 47= 1, 3 403585101 2 SpeedTrol Unit Code 47= 2, 4 910139364 2 2 235 HP1, 2 Switch- High Pressure 403585001 2 237 SPTRL Switch- SpeedTrol Pressure Code 47= 2, 4 403586901 2 1

Harness- Switch SpeedTrol Pressure 403586601 2 238 Valve Core 026541100 10 239 Valve Cap FanTrol Unit Code 47= 1, 3 032943500 6 SpeedTrol Unit Code 47= 2, 4 032943500 4 244 AFD11, 21 Inverter 208/230V 193475804 2 Inverter 460V 193475821 2 Inverter 575V 193456301 2 246 LR11, 21 Line Reactor 575V only (Code 09= 37) 073323552 2 N/S TC12, 14 Temperature Control- FanTrol 3 065498401 2N/S= Not shown on diagram.1 On FanTrol units, there is a Valve Core and Valve Cap (Ref. # 238, 239) in place of each of the SPTRL Switches.2 This Pressure Switch replaces a Switch with a lower pressure rating. P/N 910139364 has the currently recommended pressure

ratings.3 TC12, 14 are only used when the unit has no temperature controls (Code 12= Y*).

Page 159: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 159

Section M- Condenser SectionRPS/RDT Pressure Controls Box- 045- 068D: (04/2013 & Later)

AFD11, AFD21, LR11, LR21, LP1, LP2, HP1, HP2, TC12, TC14(Note: For RCS units, the SpeedTrol Inverters— AFD11, AFD21— and Line Reactors— [575V only]— are located in the RCS control

box, and the pressure controls for the compressor and FanTrol are located on the control box manifolds.)

235

238 239

234 238235

233238

Ref. Sch. Part Part Qty. No. Sym. Description Number 233, 234 LP1, 2 Switch- Low Pressure FanTrol Unit Code 47= 1, 3 403585101 2 SpeedTrol Unit Code 47= 2, 4 910139364 2 235 HP1, 2 Switch- High Pressure 403585001 2 236 PC13, 23 Switch- Fan Pressure 403585601 2 237 SPTRL Switch- SpeedTrol Pressure Code 47= 2, 4 403586901 1 2 238 - Valve Core 026541100 10 239 - Valve Cap FanTrol Unit Code 47= 1, 3 032943500 6 SpeedTrol Unit Code 47= 2, 4 032943500 4 243, 244 VFD11, 21 SpeedTrol VFD Code 54= YY 208/230V, 1HP 193552243 2 2 460V, 1HP 193552293 2 2 575V, 1HP 193456301 3 2 243 VFD11 SpeedTrol VFD Code 54= BM 208/230V 193552243 2 1 460V, 1HP 193552293 2 1 575V, 1HP 193456301 3 1 244 VFD21 SpeedTrol VFD Code 54= BM 208/230V 193552214 2 1 460V, 3HP 193552201 2 1 575V 193456301 3 1 246 LR11, 21 Line Reactor 575V only (Code 09= 37) 073323552 21 On FanTrol units, there is a Valve Core and Valve Cap (Ref. # 238, 239) in place of each of the SPTRL Switches.2 Note that ABB brand VFDs are offered as STANDARD. Confirm brand of VFD required BEFORE ordering or contact Daikin

Applied. The replacement ABB brand VFD Keypad is p/n 3000409243 For replacement VFD components, contact Daikin Applied with model and serial number information so that the correct part(s)

can be identified.

237

237

246

See Factory Supplied Line Voltage Box

Section 247

250

243

244238 239

Page 160: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 160

Section M- Condenser SectionRPS/RDT Pressure Controls Box- 070D- 079D: (03/2013 & Earlier)

AFD11, AFD21, LR11, LR21, LP1, LP2, HP1, HP2, PC13, PC23

(Note: For RCS units, the SpeedTrol Inverters— AFD11, AFD21— and Line Reactors— [575V only]— are located in the RCS control box, and the pressure controls for the compressor and FanTrol are located on the control box manifolds.)

Ref. Sch. Part Part Qty. No. Sym. Description Number 234 LP1, 2 Switch- Low Pressure FanTrol Unit Code 47= 1, 3 403585101 2 SpeedTrol Unit Code 47= 2, 4 910139364 2 2 235 HP1, 2 Switch- High Pressure 403585001 2 236 PC13, 23 Switch- Fan Pressure 403585601 2 237 SPTRL Switch- SpeedTrol Pressure Code 47= 2, 4 403586901 2 1

238 Valve Core 026541100 10 239 Valve Cap FanTrol Unit Code 47= 1, 3 032943500 6 SpeedTrol Unit Code 47= 2, 4 032943500 4

244 AFD11, 21 Inverter 208/230V 193475804 2 Inverter 460V 193475821 2 Inverter 575V 193456301 2

246 LR11, 21 Line Reactor 575V only (Code 09= 37) 073323552 2

237

AFD11 AFD21

LR11 LR21

PC23

SPTRL

SPTRL

HP1

HP2

LP1

LP2

PC13236

237

235

234234

236

235

244

246

238 239 typ.

238

238

238

238

238

238

1 On FanTrol units, there is a valve core (Ref. # 238) and valve cap in place of each of the SPTRL switches.2 This Pressure Switch replaces a Switch with a lower pressure rating. P/N 910139364 has the currently recommended pressure

ratings.

Page 161: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 161

Section M- Condenser SectionRPS/RDT Pressure Controls Box- 070- 079D: (04/2013 & Later)AFD11, AFD21, LR11, LR21, LP1, LP2, HP1, HP2, PC13, PC23

(Note: For RCS units, the SpeedTrol Inverters— AFD11, AFD21— and Line Reactors— [575V only]— are located in the RCS control box, and the pressure controls for the compressor and FanTrol are located on the control box manifolds.)

239

237

235

244

236

237

234

243

238

239238

238

238

238

238

See Factory Supplied Line Voltage Box

Section

233

238

247

236 238

235

Ref. Sch. Part Part Qty. No. Sym. Description Number 233, 234 LP1, 2 Switch- Low Pressure FanTrol Unit Code 47= 1, 3 403585101 2 SpeedTrol Unit Code 47= 2, 4 910139364 2 235 HP1, 2 Switch- High Pressure 403585001 2 236 PC13, 23 Switch- Fan Pressure 403585601 2 237 SPTRL Switch- SpeedTrol Pressure Code 47= 2, 4 403586901 1 2 238 - Valve Core 026541100 10 239 - Valve Cap FanTrol Unit Code 47= 1, 3 032943500 6 SpeedTrol Unit Code 47= 2, 4 032943500 4 243, 244 VFD11, 21 SpeedTrol VFD Code 54= YY 208/230V, 1HP 193552243 2 2 460V, 1HP 193552293 2 2 575V, 1HP 193456301 3 2 243 VFD11 SpeedTrol VFD Code 54= BM 208/230V 193552243 2 1 460V, 1HP 193552293 2 1 575V, 1HP 193456301 3 1 244 VFD21 SpeedTrol VFD Code 54= BM 208/230V 193552214 2 1 460V, 3HP 193552201 2 1 575V 193456301 3 11 On FanTrol units, there is a Valve Core and Valve Cap (Ref. # 238, 239) in place of each of the SPTRL Switches.2 Note that ABB brand VFDs are offered as STANDARD. Confirm brand of VFD required BEFORE ordering or contact Daikin

Applied. The replacement ABB brand VFD Keypad is p/n 3000409243 For replacement VFD components, contact Daikin Applied with model and serial number information so that the correct part(s)

can be identified.

Page 162: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 162

Section M- Condenser SectionCondenser Control Box (RCS Units Only)

No Controls: Code 12= YM 1

Diagrams 2

1 For more information on RCS Standalone Units (Code 12= YA, 1A, 2A) refer to form # 7000136.2 The above diagrams show typical Condenser Control Box layouts and are to be used for reference only. Specific

unit configuration may differ depending upon unit size and options selected.

RCS with no controls: Code 12= YM 03/2013 & Earlier

RCS with no controls: Code 12= YM 04/2013 & Later

Page 163: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 163

Section M- Condenser SectionCondenser Control Box (RCS Units Only)

MicroTech III ControlsCode 12= LE, LF, BE, BF, EE, EF, SE, SF

Diagrams 1

RCS with MicroTech III Controls: 03/13 & Earlier

RCS with MicroTech III Controls: 04/13 & Later

1 The above diagrams show typical Condenser Control Box layouts and are to be used for reference only. Specific unit configuration may differ depending upon unit size and options selected.

Page 164: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 164

Sch. Part Part Qty. Sym. Description Number DCC DCC Digital Compressor Controller 910139658 1 S2 Switch- System 001355000 1 REC2 Receptacle 039003600 1 Relays R1 Relay- Hi Pressure Reset 349934724 1 R2 Relay- Hi Pressure Reset 349934724 1 R5 Relay- Safety 349934724 1 R6 Relay- Safety 349934724 1 R7 Relay- Safety 349934724 1 R8 Relay- Safety 349934724 1 R12 Relay- Condenser Fan (MTIII) 349934724 1 R31- 36 Relay- Compressor Staging 349934722 var. Ground Fault Protection GFR4 Ground Fault Relay- SPDT Code 17= YG, YC 349937502 1 GFS4 Ground Fault Sensor Code 17= YG, YC 349937407 1 Phase Voltage Monitor (PVM) Code 17= YP, YC PVM4 Phase Voltage Monitor 208/230/460V Units (12/16 & Earlier) 112022001 1 575V Units (12/16 & Earlier) 112022002 1 208/230/460V Units (1/17 & Later) 193599301 1 575V Units (1/17 & Later) 193599303 1 - Socket, PVM (1/17 & Later) 193599401 1 PL25-30 Plugs- 12 Pin 349930405 1/comp

Terminal Blocks TB1,3,5,6,8 Terminal Block 349930641 1 var. TB35 Terminal Block Assy. 910150442 1 TB36 Terminal Block Assy. 404148501 1 Power Block- Main Code 11= P1 PB4 Power Block, Main 175A 030372777 2 1 310A, 420A 030372785 2 1 Contactors M1- 6 Contactor- Compressors 3

M11- 24 Contactor- Fan Motors 3

Manual Motor Protector MMP1- 6 MMP- Compressor 3

MMP11- 23 MMP- Fan Motors 3

Time Delays TD1, 2 Time Delays, Compr. Lockout 4 2 TD29 Time Delay, Coil Splitter 349983901 1

Section M- Condenser SectionRCS Control Box

Components

1 Part number is for one section. Quantity of sections varies with unit options. Ground Terminal is p/n 349930647. 2 Any of the listed parts may be used, depending on unit options. Check installed part to verify, or contact Daikin Applied with unit

serial and/or GO number to ensure correct replacement is selected.3 These components are installed in the RCS unit Condenser Control Box however, Compressor and Condenser Fan Motor

Contactors and associated parts are detailed in the Main Control Box Section (Section N). 4 Two Time Delay relays have been furnished. The most common is the NON-Adjustable type p/n. 193464401. The ADJUSTABLE

version of this relay could also have been supplied: p/n. 300046580. Confirm which relay is required BEFORE ordering.

Page 165: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 165

Section M- Condenser SectionRCS Control Box

Components, Continued

Disconnect Switches 03/13 & Earlier Sch. Part Part Voltage Sym. Description Number 208V 230V 460V 575V Disconnect Switch 1

DS4 Disconnect Switch- Condenser Control Box Switch- 100A 349935125 1 1 1 1 Handle Kit (with operating mechanism) 349935521 1 1 1 1 Shaft 349962208 1 1 1 1 Ground Lug 349938001 1 1 1 1 Switch- 150A 349935126 1 1 1 1 Handle Kit (with operating mechanism) 349935532 1 1 1 1 Shaft 349962208 1 1 1 1 Ground Lug 349938001 1 1 1 1 Switch- 250A 349935226 1 1 1 1 Handle Kit (with operating mechanism) 349935532 1 1 1 1 Shaft 349962208 1 1 1 1 Ground Lug 349938002 1 1 1 1 Switch- 400A 349935325 1 1 1 1 Handle Kit (with operating mechanism) 349935621 1 1 1 1 Shaft 349962210 1 1 1 1 Ground Lug 349938002 1 1 1 1 1 Disconnects are sized according to various unit specifications. Check installed switch to verify the correct DS4 size, or contact Daikin

Applied with model and serial number information so that the required part(s) can be identified. For DS1s larger than 400A, contact Daikin Applied with model and serial number information so that the correct part(s) can be identified.

Ref. Part Part Voltage No. Description Number 208V 230V 460V 575V Disconnect Switch 2

DS4 Disconnect Switch- Condenser Control Box Switch- 100A 193444703 1 1 1 1 Handle 193422102 1 1 1 1 Shaft 3 193596420 1 1 1 1 Switch- 150A 193585101 1 1 1 1 Handle 193422102 1 1 1 1 Mechanism 193550801 1 1 1 1 Shaft 3 193596420 1 1 1 1 Lugs 5 193553301 1 1 1 1 Switch- 250A 193551601 1 1 1 1 Handle 193595701 1 1 1 1 Mechanism 193551001 1 1 1 1 Shaft 4 300049193 1 1 1 1 Lugs 5 193553801 1 1 1 1 Switch- 400A 193551701 1 1 1 1 Handle 193595701 1 1 1 1 Mechanism 193551001 1 1 1 1 Shaft 4 300049193 1 1 1 1 Lugs 5 193554001 1 1 1 1 2 Disconnects are sized according to various unit specifications. Check installed switch to verify the correct DS4 size, or contact

Daikin Applied with model and serial number information so that the required part(s) can be identified. For DS1s larger than 400A, contact Daikin Applied with model and serial number information so that the correct part(s) can be identified.

3 This shaft is 14.25” OAL and is designed to be cut to length in the field.4 This shaft is 7.21” (183mm) OAL and is designed to be cut to length in the field. For a 19.69” (500mm) OAL use p/n 300040299.5 Three Lugs are included with each p/n.

Disconnect Switches 04/13 & Later

Page 166: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 166

L1 L2 L3

FU6A

FU6B

FU6C

T1 T2 T3

T6 DS6

Section M- Condenser SectionFactory Supplied Line Voltage Box- Powered Receptacle and Lights T6, DS6, FU6A, FU6B, FU6C: Code 18= U***, V*** OR Code 23= ***F*

3

8

92

Voltage

Ref. Sch. Part Part No. Sym. Description Number 2 T6 Transformer 2KVA 349987001 1 Transformer 2KVA 349987002 1 1 Transformer 2KVA 349987003 1 3 DS6 Disconnect Switch 30A/600V 349991901 1 1 1 1 8 FU6A,B Fuse 20A/600V 193403711 2 2 Fuse 10A/600V 193403708 2 Fuse 8A/600V 193403707 2 9 FU6C Fuse 20A/600V 193403711 1 1 1 1

208V

230V

460V

575V

03/13 & Earlier

04/13 & Later

Voltage Ref. Sch. Part Part No. Sym. Description Number 01 DS6 Fuse Holder/Circuit Protector 2P, 30A, 600V 193443801 1 1 1 1 02 FU6A, B Fuse 20A/600V 300042980 2 2 Fuse 10A/600V 049759816 2 Fuse 8A/600V 049759814 2 03 TB7 Terminal, 2 x 2 Green 349930647 1 1 1 1 04 Terminal Block End Plate 349930741 1 1 1 1 05 Terminal, 2 x 2 Grey 349930641 2 2 2 2 06 Terminal Block End Stop Grey 349930841 2 2 2 2 247 T6 Transformer 2KVA 099477214 1 Transformer 2KVA 099477114 1 1 Transformer 2KVA 099477314 1 248 - Terminal Cover Kit 099477601 1 1 1 1 249 FU6C Fuse 20A/600V 042753123 1 1 1 1

208V

230V

460V

575V

Pressure Controls Box(070- 079D shown)

247

DS6

TB7

Main Control Box

0403

01

0605 248

249

02

Page 167: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 167

Section N- Main Control BoxNotes

Primary Codes that pertain: 08, 09, 11, 12, 13, 14, 15, 16, 17, 18, 23 (Mid 2012 & Later), 68Additional Codes that pertain: 04, 19, 20, 22, 27, 30, 32, 34, 35, 40, 47

The Main Control Box applies to the RPS, RFS, and RDT. The RCS has its own Controls that are detailed in Section M. The Main Control Box is comprised of three primary parts— The Deadfront Door with the Keypad, the Control Panel, and the Power Panel.

In March and April of 2013, the Main Control Box underwent a major redesign. This design change not only changed components, but some Contactor, Motor Protector, and VFD circuiting changed. Note that components and component accessories such as Auxiliaries, Links, etc. are NOT interchangeable. For units built and shipped during the transition, confirm which design was used, or contact Daikin Applied to ensure that the correct part(s) are identified.

Code 08 determines where the Control Box is installed- “D” indicates the discharge plenum (RPS, RFS), “F” indicates the supply air section (RDT).

Code 9 is the unit voltage and affects Transformers, Fan Overloads/MMPs, Contactors, Fuses, etc.

Code 11 determines whether the main power connection is a Power/Terminal Block OR a through-the-door Disconnect.

Code 12 determines which type of communication option the unit has (LonMark, BACNet/MSTP, BACNet/IP, OR none) and whether the unit uses Discharge Temperature, Space Control, OR Zone control. There is an MCB and separate Expansion Boards (Condenser, Electric Heat, Energy Recovery) in the Control Box. Units may also have no unit controls (Code 12= YM, YC) in which case the Main Control Box has no MCB OR Expansion boards, but instead has a set of relays. RCS Standalone Units (units that are designed to be used as a standalone condensing unit, OR intended to be hooked to a separate Air Handler unit) have additional codes which add Transformers. For RCS Standalone Unit specific information, (Code 12= *A), refer to RPL form # 7000136.

Code 13 determines the presence of Duct and/or Space Sensors.

Codes 14 and 15 determine the Supply and Return Fan Inverter characteristics.

Code 16 determines the presence of Smoke Detectors.

Code 17 AND/OR 23 (Mid 2012 & Later) determine miscellaneous electrical options including whether the unit has a Freezestat, PVM (Phase Voltage Monitor), Ground Fault Protection, Line Reactors, Vestibule Lights, Service Outlet, Intelligent Equipment, etc.

Code 68 specifies the SCCR or “Short Circuit Current Rating” for the unit. Standard units are always rated at “10 SCCR” (Code 68= 10, OR no entry). An entry with any other rating (Eg: Code 68= 22, 65 OR indicated in the specials description in the Code String lookup) may change disconnect switches, circuit breakers, fuses, and other miscellaneous components. When control box parts are required for units with nonstandard SCCR ratings, contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. Code 18 indicates whether a unit has a Remote Keypad Display and/or a unit mounted Receptacle.

Codes 19, 20 and 22 are return air codes, and impact several controls options. The presence of an OA hood, the horsepower of the Return Air Motor, etc, have an impact on Contactors, Motor Protectors, Fuses, and Duct Sensors.

Code 27 determines the draw through section, and can impact the Cooling Circuit Relays.

Code 32 determines horsepower for the Supply Fan Motor which, like the Return Air Motor, will affect Contactors, Motor Protectors, Fuses, Overloads, etc.

Codes 04, 30, (RDT) 34, and 35 determine the BlowThru section, and the heat type, which will impact the Transformers, heat circuit Relays, and cooling circuit Relays.

Code 40 determines if there is a VAV/Discharge Damper and associated Relay.

Code 47 determines if the unit has SpeedTrol fan control and affects the condenser fan fusing, and whether there are SpeedTrol Inverters and associated components.

Page 168: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 168

Section N- Main Control BoxControl Box Component Label Diagram 1

1 Note that starting in late 2010 all units will have a label similar to the one shown above pasted to the inside of the Control Box door. This label contains schematic designators, part descriptions, and Daikin Applied part numbers. The label shown above is for representative purposes only. Actual part numbers will vary depending upon unit size and options selected.

Page 169: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 169

Section N- Main Control BoxControl Panel - No Controls

(Code 12= YM, YC)Diagrams 1

Left Side Door Detail

DHL

See Power Panel

R1

R2

R24

R20

R25

R19

R18

R63

R8.1

R5.1

R6.1

R7.1

R9

R10

R11

Switches Detail

S4 S7

HS1 S1 CS2 CS1

Left SideDoor

R69

R68

R70

TD1 TD2

R67

R17

R13.1

R14.1

T4 T2

1 The above diagram shows a typical Main Control Box layout and is to be used for reference only. Specific unit configuration may differ depending upon unit size and options selected.

Page 170: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 170

Sch. Part Part Qty. Sym. Description Number Switches- Control HS1 Switch- Electric Heat Shutdown Code 04= E 001355000 1 CS1,2 Switch- Control 001355000 2 S1 Switch- System On/Off Gas Heat Units Code 04= A 018446400 1 Elec.,Steam,HW, No Heat Code 04= E, S, W, Y 001355000 1 S4 Switch- Inverter Bypass On/Off 028798400 1 S7 Switch- Local On/Auto/Off 349931201 1 Relays R1 Relay- Hi Pressure Reset 349934724 1 R2 Relay- Hi Pressure Reset 349934724 1 R5.1 Relay- Safety 349934724 1 R6.1 Relay- Safety 349934724 1 R7.1 Relay- Safety 349934724 1 R8.1 Relay- Safety 349934724 1 R9 Relay- Compressor Lockout 349934724 1 R10 Relay- Compressor Lockout 349934724 1 R11 Relay- SpeedTrol Inverter Code 47= 2, 4 349934724 1 R13.1 Relay- Safety 349934724 1 R14.1 Relay- Safety 349934724 1 R17 Relay- SpeedTrol Inverter Code 47= 2, 4 349934724 R18 Relay- Cooling Failure Indicator 349934722 1 R19 Relay- Cooling Failure Indicator 349934722 1 R20 Relay- Steam, Hot Water Heat Code 04= S, W 349934724 1 Relay- Electric Heat Code 04= E 349934722 1 Relay- Gas Heat 1 Code 04= A Units w/Gas Actuator Code 12= YC Hi Turn Down Burner Code 34 (5th digit)= H, T, U 073340001 1 Modulating Burner Code 34 (5th digit)= E, R, S 027400700 1 Units w/Float Control Code 12= YM Hi Turn Down Burner Code 34 (5th digit)= H, T, U 019643000 1 Modulating Burner Code 34(5th digit)= E, R, S 027400700 1 R24 Relay- Gas Heat Alarm Code 04= A 349934724 1 R25 Relay- Gas Heat, Start Supply Fan Inverter Code 14= 1, 2,3,5,6,7 349934724 1 R63 Relay- Specials 349934921 1 R67 Relay- Supply Fan Enable With Inverter Bypass Code 14= 1- 5 349934724 1 No Inverter Bypass Code 14= 6- 9 349934722 1 R68 Relay- Return Fan Enable 349934724 1 R69 Relay- Inverter Bypass VAV Interlock Code 14= 1- 9 349934724 1 R70 Relay- Specials 349934722 1 Duct Hi Limit Switch DHL Duct Hi Limit Switch 065493801 1 Transformers- Controls T2 Transformer- Control Input 115- 24V 349937203 1 T4 Transformer- Exhaust Damper Actuator 115- 12VDC 349931801 1

Section N- Main Control BoxControl Panel - No Controls (Code 12= YM, YC)

Components

1 All R20 options are detailed here but for units with gas heat, the R20 is located in the gas heat control box (see section G).

Page 171: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 171

Section N- Main Control BoxControl Panel- MicroTech III Units with Controller: (03/2013 & Earlier)

Code 12= *E, *F, *W- Diagram 1

See Power Panel

1 The above diagram shows a typical Main Control Box layout and is to be used for reference only. Specific unit configuration may differ depending upon unit size and options selected.

Page 172: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 172

Sch. Part Part Qty. Sym. Description Number Main Controller MCB Main Controller- Must be programmed (unit GO# required) 193407301 1 Connector, Extension I/O Direct Connect 1 193409701 2

Terminal Block, MCB- 2 Pole 193410302 1 Terminal Block, MCB- 3 Pole 193410303 6 Terminal Block, MCB- 5 Pole 193410305 1 Terminal Block, MCB- 6 Pole 193410306 1 Terminal Block, MCB- 7 Pole 193410307 1 Terminal Block, MCB- 8 Pole 193410308 2 - MicroTech III Remote Unit Keypad/Interface Display 1 193408003 1 Expansion Module EXP A Expansion Module- Condenser/ Energy Recovery 1 193407501 1 EXP B Expansion Module- Heat 193407501 1 EXP D Expansion Module- Specials 1 193407501 1 Terminal Block, EXP- 2 Pole 193410302 1/board Terminal Block, EXP- 3 Pole 193410303 1/board Terminal Block, EXP- 7 Pole 193410307 1/board Terminal Block, EXP- 8 Pole 193410308 2/board Communication Card COM Bacnet- MSTP Code 12= BE, BF, BW 090016710 1 Bacnet- IP Code 12= EE, EF, EW 090016709 1 LonWorks- Discharge (Code 12= LE, LW) 090016712 1 LonWorks- Constant Volume (Code 12= LF) 090016711 1 Resistors 1

RES1 Resistor- Refrigeration Circuit #1 1500 OHM 044690151 1 RES2 Resistor- Refrigeration Circuit #2 1000 OHM 044690110 1 RES3 Resistor- Freezestat (FS1) 1000 OHM 044690110 1 RES4 Resistor- OAE 1500 OHM 044690151 1 RES6,7,8 Resistor- SPS1, SPS2, SPS3 500 OHM 044690146 1/switch Switches- Control HS1 Switch- Electric Heat Shutdown Code 04= E 001355000 1 S1 Switch- System On/Off Gas Heat Units with no UV Lights DPST/15A 018446400 1 Gas Heat Units with UV Lights 4PST/30A 033536700 1 Electric, Steam, HW, No Heat with no UV Lights SPST/20A 001355000 1 Electric, Steam, HW, No Heat with UV Lights DPST/15A 018446400 1 S4 Switch- Inverter Bypass On/Off DPST/15A 018446400 1 S7 Switch- Local On/Auto/Off to Controller SPDT/15A 193412101 1 Transformers T2 Transformer- Control 120- 24V 349937303 1 T3 Transformer- Control 120- 24V 349937303 1 Duct Hi Limit and Static Pressure Sensors DHL Duct Hi Limit Switch 065493801 1 SPS1, 2 Pressure Transducer Kit- Duct Sensor (9/11 & Earlier) 3, 4 910124528 2

Pressure Transducer- Duct Sensor (10/11 thru 3/13) 3 910117462 2

Pressure Transducer Kit- Space Sensor (9/11 & Earlier) 3, 4 910124529 2

Pressure Transducer- Space Sensor (10/11 thru 3/13) 3 910117463 2

1 Not Shown on diagram. 2 Quantity varies depending upon unit size and options selected.3 SPS1 Duct Sensor Code 13= 1, 2, 3. SPS2 Duct Sensor Code 13= 2. SPS2 Space Sensor Code 13= 3, 4.4 As of 09/11 the original Pressure Transducer is no longer available. The Transducer Kit includes Transducer, Dinrail,

Resistor, Sampling Tube, and installation Instructions.

Section N- Main Control BoxControl Panel- MicroTech III Units with Controller: (03/2013 & Earlier)

Code 12= *E, *F, *W- Components

Page 173: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 173

Sch. Part Part Qty. Sym. Description Number Relays R11 Relay- SpeedTrol inverter AFD11 349934724 1 R12 Relay- Condenser Fan 349934724 1 R13 Relay- Condenser Fan 349934724 1 R14 Relay- Condenser Fan 349934724 1 R17 Relay- SpeedTrol inverter AFD21 349934724 1 R20 Relay- Heat 349934724 1 R22 Relay- Gas Heat 349934724 1 R24 Relay- Gas Heat Alarm 349934724 1 R25 Relay- Gas Heat, Start Supply Fan Inverter Code 14= 1,2,3,5,6,7 349934724 1 R26 Relay- Iso Damper- Open/Close 349934722 1 R28 Relay- Isolation Damper Safety 349934722 1 R45 Relay- UV Lights 349934722 1 R63 Relay- Duct Hi Limit Units with Supply Fan Inverter Code 14= 1, 3, 6 0 OR 1 Duct Sensor Code 13= Y, 1 349934724 1 2 Duct Sensors Code 13= 2 349934923 1 1 Duct & Space Sensor OR 1 Space Sensor Code 13= 3, 4 349934923 1 DHL Sensor Code 13= 5 349934921 1 Units with Supply & Return Fan Inverters Code 14= 2, 5, 7 Vars. Code 13= 1, 2, 3, 4, Y 349934923 1 R81 Relay- Inverter Reset 4P/6A/24V 349934722 1 R82 Relay- Inverter Reset 4P/6A/24V 349934722 1 R83 Relay- Smoke 4P/6A/24V 193413601 1 R84 Relay- Smoke 4P/6A/24V 193413601 1 R85 Relay- Smoke 4P/6A/24V 193413601 1 R86 Relay- Smoke 4P/6A/24V 193413601 1 R87 Relay- Smoke 4P/6A/24V 193413601 1 R88 Relay- Smoke 4P/6A/24V 193413601 1 Time Delays TD20 Time Delay- Return Air Fan 028210106 1 Terminal Block TB1 Terminal Block 349930641 1

Sensors SHS1 Sensor, Humidity Duct Mounted 3 067295001 Sensor, Humidity Wall Mounted 3 067294901 ZNT1 Sensor- Zone Temperature w/ Tenant Override 3 113117701 1 Sensor- Zone Temp. w/ Tenant Override & Remote Setpoint Adj.2, 3 113117801 1 DAT Sensor- Discharge Air Temperature 3 193414602 1 EFT Sensor- Entering Air Temperature 3 193414602 1 OAT Sensor- Outside Air Temperature 3 193414602 1 RAT Sensor- Return Air Temperature 3 193414602 1 EAT Sensor- Exhaust Air Temperature 3 193414602 1 LAT Sensor- Leaving Air Temperature 3 193414602 11 Varies depending on unit options. Part number is for one individual section. Ground block is p/n 349930647.2 SCC Units only- Code 12= BF, LF, EF, SF.3 Not Shown on diagram.

Section N- Main Control BoxControl Panel- MicroTech III Units with Controller: (03/2013 & Earlier)

Code 12= *E, *F, *W- Components, Continued

Page 174: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 174

Section N- Main Control BoxControl Panel- MicroTech III Units with Controller: (04/2013 & Later)

Code 12= *E, *F, *W- Diagram 1

1 The above diagram shows a typical Main Control Box layout and is to be used for reference only. Specific unit configuration may differ depending upon unit size and options selected.

PL1

- PL4

3 Pl

ugs

See Power Panel

See

Pow

er P

anel

Page 175: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 175

Sch. Part Part Qty. Sym. Description Number Main Controller MCB Main Controller- Must be programmed (unit GO# required) 193407301 1 Connector, Extension I/O Direct Connect 193409701 2

Terminal Block, MCB- 2 Pole 193410302 1 Terminal Block, MCB- 3 Pole 193410303 6 Terminal Block, MCB- 5 Pole 193410305 1 Terminal Block, MCB- 6 Pole 193410306 1 Terminal Block, MCB- 7 Pole 193410307 1 Terminal Block, MCB- 8 Pole 193410308 2 - MicroTech III Remote Unit Keypad/Interface Display 1 193408003 1 DCC Digital Compressor Controller 1 910139658 1 Expansion Module EXP A Expansion Module- Condenser/ Energy Recovery 1 193407501 1 EXP B Expansion Module- Heat 193407501 1 EXP D Expansion Module- Specials 1 193407501 1 Terminal Block, EXP- 2 Pole 193410302 1/board Terminal Block, EXP- 3 Pole 193410303 1/board Terminal Block, EXP- 7 Pole 193410307 1/board Terminal Block, EXP- 8 Pole 193410308 2/board Hot Gas Reheat 1

RHB1, 2 Hot Gas Reheat Interface Boards Code 54= BM, BL 113168901 2 Communication Card COM Bacnet- MSTP Code 12= BE, BF, BW 090016710 1 Bacnet- IP Code 12= EE, EF, EW 090016709 1 LonWorks- Discharge (Code 12= LE, LW) 090016712 1 LonWorks- Constant Volume (Code 12= LF) 090016711 1 Resistors 1

RES1 Resistor- Refrigeration Circuit #1 1500 OHM 044690151 1 RES2 Resistor- Refrigeration Circuit #2 1000 OHM 044690110 1 RES3 Resistor- Freezestat (FS1) 1000 OHM 044690110 1 RES4 Resistor- OAE 1500 OHM 044690151 1 RES6,7,8 Resistor- SPS1, SPS2, SPS3 500 OHM 044690146 1/switch Switches- Control HS1 Switch- Electric Heat Shutdown Code 04= E 001355000 1 S1 Switch- System On/Off Gas Heat Units with no UV Lights DPST/15A 018446400 1 Gas Heat Units with UV Lights 4PST/30A 033536700 1 Electric, Steam, HW, No Heat with no UV Lights SPST/20A 001355000 1 Electric, Steam, HW, No Heat with UV Lights DPST/15A 018446400 1 S4 Switch- Inverter Bypass On/Off DPST/15A 018446400 1 S7 Switch- Local On/Auto/Off to Controller SPDT/15A 193412101 1 Transformers T2 Transformer- Control 120- 24V 349937303 1 T3 Transformer- Control 120- 24V 349937303 1 Duct Hi Limit and Static Pressure Sensors DHL Duct Hi Limit Switch 065493801 1 SPS1, 2 Pressure Transducer- Duct Sensor 3 910117462 1 Pressure Transducer- Space Sensor 3 910117463 1 Snubber, Pressure Transducer (optional; field installed) 910181702 1, 2

1 Not Shown on diagram. 2 Quantity varies depending upon unit size and options selected.3 SPS1 Duct Sensor Code 13= 1, 2, 3. SPS2 Duct Sensor Code 13= 2. SPS2 Space Sensor Code 13= 3, 4.

Section N- Main Control BoxControl Panel- MicroTech III Units with Controller: (04/2013 & Later)

Code 12= *E, *F, *W- Components

Page 176: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 176

Sch. Part Part Qty. Sym. Description Number Relays R11 Relay- SpeedTrol inverter VFD11 349934724 1 R12 Relay- Condenser Fan 349934724 1 R13 Relay- Condenser Fan 349934724 1 R14 Relay- Condenser Fan 349934724 1 R17 Relay- SpeedTrol inverter VFD21 349934724 1 R20 Relay- Heat 349934724 1 R22 Relay- Gas Heat 349934724 1 R24 Relay- Gas Heat Alarm 349934724 1 R25 Relay- Gas Heat, Start Supply Fan Inverter Code 14= 1,2,3,5,6,7 349934724 1 R26 Relay- Iso Damper- Open/Close 349934722 1 R28 Relay- Isolation Damper Safety 349934722 1 R45 Relay- UV Lights 349934722 1 R63 Relay- Duct Hi Limit Units with Supply Fan Inverter Code 14= 1, 3, 6 0 OR 1 Duct Sensor Code 13= Y, 1 349934724 1 2 Duct Sensors Code 13= 2 349934923 1 1 Duct & Space Sensor OR 1 Space Sensor Code 13= 3, 4 349934923 1 DHL Sensor Code 13= 5 349934921 1 Units with Supply & Return Fan Inverters Code 14= 2, 5, 7 Vars. Code 13= 1, 2, 3, 4, Y 349934923 1 R81 Relay- Inverter Reset 4P/6A/24V 349934722 1 R82 Relay- Inverter Reset 4P/6A/24V 349934722 1 R83 Relay- Smoke 4P/6A/24V 193413601 1 R84 Relay- Smoke 4P/6A/24V 193413601 1 R85 Relay- Smoke 4P/6A/24V 193413601 1 R86 Relay- Smoke 4P/6A/24V 193413601 1 R87 Relay- Smoke 4P/6A/24V 193413601 1 R88 Relay- Smoke 4P/6A/24V 193413601 1 Time Delays TD20 Time Delay- Return Air Fan 028210106 1 Terminal Block TB1 Terminal Block 349930641 1

Sensors SHS1 Sensor, Humidity Duct Mounted 3 12/16 & Earlier 067295001 Sensor, Humidity Duct Mounted 3 1/17 & Later 910190890 Sensor, Humidity Wall Mounted 3 067294901 ZNT1 Sensor, Digital- Zone Temperature w/ Tenant O/R & Setpoint Adj. 4 910143408 1 Sensor- Zone Temperature w/ Tenant Override 4 113117701 1 Sensor- Zone Temp. w/ Tenant Override & Remote Setpoint Adj. 2, 4 113117801 1 DAT Sensor- Discharge Air Temperature 3 193414602 1 EFT Sensor- Entering Air Temperature 3 193414602 1 OAT Sensor- Outside Air Temperature 3 193414602 1 RAT Sensor- Return Air Temperature 3 193414602 1 EAT Sensor- Exhaust Air Temperature 3 193414602 1 LAT Sensor- Leaving Air Temperature 3 193414602 1

Section N- Main Control BoxControl Panel- MicroTech III Units with Controller: (04/2013 & Later)

Code 12= *E, *F, *W- Components, Continued

10

50

1456

22

68

30

86

2680

°F

°C

62 7418

ZNT1 Sensor910143408

ZNT1 Sensor113117701

ZNT1 Sensor113117801

1 Varies depending on unit options. Part number is for one individual section. Ground block is p/n 349930647.2 SCC Units only (Code 12= *F).3 Not Shown on diagram.4 In late 2013, Digital Room Sensor p/n 910143408 was added as the preferred option. The other Zone Temperature Sensors

are available as options. For positive p/n identification, refer to the drawings below.

Page 177: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 177

Section N- Main Control BoxPower Panel: (03/2013 & Earlier)

Diagrams 1

See Control Panel

See C

ontrol Panel

1 The above diagram shows a typical Power Panel layout and is to be used for reference only. Specific unit configuration may differ depending upon unit size and options selected.

PL1

- PL4

3 Pl

ugs

See

Con

trol

Pan

el

Page 178: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 178

Sch. Part Part Voltage Sym. Description Number 208V 230V 460V 575V Terminal Blocks TB2,3,4,7 Terminal Block 349930641 1 1 1 1

Transformer- Main 3

T1 Transformer- Main Control Electric, Hydronic, No Heat Code 04= E,S,W,Y Units without UV Lights 038253974 1 Units without UV Lights 038253956 1 1 Units without UV Lights 038253983 1 Units with UV Lights Code 17 (2nd digit)= 1- 8 038253975 1 Units with UV Lights Code 17 (2nd digit)= 1- 8 038253957 1 1 Units with UV Lights Code 17 (2nd digit)= 1- 8 038253984 1 Gas Heat Code 04= A Units without UV Lights 038253975 1 Units without UV Lights 038253957 1 1 Units without UV Lights 038253984 1 Units with UV Lights Code 17 (2nd digit)= 1- 8 038253976 1 Units with UV Lights Code 17 (2nd digit)= 1- 8 038253958 1 1 Units with UV Lights Code 17 (2nd digit)= 1- 8 038253985 1 Fuses- T1 F1A, B Fuse- T1 Transformer, Primary Electric, Hydronic, No Heat Code 04= E,S,W,Y Units without UV Lights 300042152 2 Units without UV Lights 049759816 2 Units without UV Lights 049759811 2 Units without UV Lights 049759814 2 Units with UV Lights Code 17 (2nd digit)= 1- 8 349937134 2 Units with UV Lights Code 17 (2nd digit)= 1- 8 349937133 2 Units with UV Lights Code 17 (2nd digit)= 1- 8 049759814 2 Units with UV Lights Code 17 (2nd digit)= 1- 8 349937125 2 Gas Heat Code 04= A Units without UV Lights 349937134 2 Units without UV Lights 349937133 2 Units without UV Lights 049759814 2 Units without UV Lights 349937125 2 Units with UV Lights Code 17 (2nd digit)= 1- 8 349937135 2 2 Units with UV Lights Code 17 (2nd digit)= 1- 8 049759816 2 Units with UV Lights Code 17 (2nd digit)= 1- 8 349937130 2 F1C Fuse- T1 Transformer 349937036 4 1 1 1 1 Fuse- T1 Transformer 349937035 4 1 1 1 1 Fuse- T1 Transformer 042753121 4 1 1 1 1

Power Panel- Terminal Blocks, T1 Transformer & Fusing

Section N- Main Control BoxPower Panel: (03/2013 & Earlier)

Components

1 Varies depending on unit options. Part number is for one individual section. Ground block is p/n 349930647. When required TB2,3,4 OR 7 use jumpers p/n 349930922 (2 pole), 349930923 (3 pole), 349930924 (4 pole), 349930925 (5 pole).

3 All T1 transformers also use a fuse puller kit p/n 349955801 & a cover kit p/n 349955901.4 Fuse depends on heat type and presence of UV lights. 349937036= Gas Heat Unit w/UV lights; 349937035= Gas Heat Unit with no

UV lights OR Non-Gas Heat Unit with UV lights; 042753121= Non- Gas Heat Units with no UV lights.

Page 179: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 179

Sch. Part Part Voltage Sym. Description Number 208V 230V 460V 575V Fuses, continued F2,F3, F5 Fuses Fuse Block 023780223 1/fuse 1/fuse 1/fuse 1/fuse Fuse Cover 349938227 1/fuse 1/fuse 1/fuse 1/fuse F2 Fuse- 2000+VA transformer 349937035 1 1 1 1 F3 Fuse- Blower Motor Code 04= A 349937035 1 1 1 1 F5 Fuse- UV Lights Code 17 (2nd digit)= 1- 8 349937032 1 1 1 1 Phase Voltage Monitor Code 17= P,A,C,D,H,J,K PVM1, 2 Phase Voltage Monitor 112022001 2 2 2 Phase Voltage Monitor 112022002 2 Ground Fault Protection Code 17= G,B,C,D,K GFR1, 2 Ground Fault Relay- SPDT 349937502 1 1 1 1 GFS1, 2 Ground Fault Sensor 349937407 1 1 1 1 Power Blocks PB1, PB2 Power Block- Main 2 Code 11= P1, Q1 Power Block, Non- Electric Heat Units- 175A 1 030372776 1 1 1 1 Power Block, Electric Heat Units- 175A 1 030372780 1 1 1 1 Lug- 175A Block 349938001 1 1 1 1 Power Block, Non- Electric Heat Units- 255A 1 030372778 1 1 1 1 Lug- 255A Block 349938001 1 1 1 1 Power Block, Non- Electric Heat Units- 380A 1 030372779 1 1 1 1 Power Block, Electric Heat- 380A 1 030372782 1 1 1 1 Lug- 380A Block 349938001 1 1 1 1 Power Block, Non- Electric Heat Units- 620A 1 030372702 1 1 1 1 Cover- 620A Block 349938345 3 3 3 3 Lug- 620A Block 349938002 1 1 1 1 Power Block, Non- Electric Heat Units- 760A 1 030372760 1 1 1 1 Power Block, Electric Heat Units, 208/230V- 760A 1 030372772 1 1 Power Block, Electric Heat Units, 460/575V- 760A 1 030372760 1 1 Cover- 760A Block 349938345 3 3 3 3 Lug- 760A Block 349938003 1 1 1 1 Power Block, Non- Electric Heat Units- 840A 1 030372724 1 1 1 1 Cover- 840A Block 349938345 3 3 3 3 Lug- 840A Block 349938003 1 1 1 1 PB11 Power Block- Power Distribution Power Block- 420A 1 030372785 1 1 1 1 Power Block- 760A 1 030372721 1 1 1 1 Cover- 760A Block 349938345 1 1 1 1 PB12 Power Block- Power Distribution Code 04= E 20, 40 KW Electric Heat 030372777 1 1 1 1 60, 80, 100, 120 KW Electric Heat 030372785 1 1 60, 80, 100, 120 KW Electric Heat 030372777 1 1 160 KW Electric Heat 030372785 1 1 1 1 200, 240 KW Electric Heat 030372785 1 1

Power Panel- Fusing, Phase Protection, Ground Fault, Power Blocks

1 Any of the listed parts may be used, depending on unit options. Check installed part to verify, or contact Daikin Applied with unit serial and/or GO number to ensure correct replacement is selected. PB2 is installed when Code 11= Q1.

2 These power blocks are used on RPS and RDT units. RFS units use the following: 175A p/n 030372777 + Lug p/n 349938302; 310A p/n 030372783 + Lug p/n 349938302; 420A p/n 030372785 + Lug 349938302; 760A p/n 030372721 + Lug p/n 349938003.

Section N- Main Control BoxPower Panel: (03/2013 & Earlier)

Components, Continued

Page 180: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 180

Sch. Part Part Voltage Sym. Description Number 208V 230V 460V 575V Power Blocks, continued PB10 Power Block- Supply Fan Code 15= F 030372776 1 1 1 1 PB20 Power Block- Return Fan Code 15= F 030372776 1 1 1 1 Receptacle REC1 Receptacle 039003600 1 1 1 1 Disconnect Switch DS1 Disconnect Switch- Main Gas, Steam, HW, No Heat (C04= A, S, W, Y) units Switch- 100A 1 349935125 1 1 1 1 Handle Kit 349935521 1 1 1 1 Shaft 349962204 1 1 1 1 Ground Lug 349938001 1 1 1 1 Switch- 150A 1 349935126 1 1 1 1 Handle Kit (with operating mechanism) 349935532 1 1 1 1 Shaft 349962205 1 1 1 1 Ground Lug 349938001 1 1 1 1 Switch- 250A 1 349935226 1 1 1 1 Handle Kit (with operating mechanism) 349935532 1 1 1 1 Shaft 349962205 1 1 1 1 Ground Lug 349938002 1 1 1 1 Switch- 400A 1 349935325 1 1 1 1 Handle Kit (with operating mechanism) 349935621 1 1 1 1 Shaft 349962206 1 1 1 1 Ground Lug 349938002 1 1 1 1 Switch- 600A 1, 2, 3, 4 193438205 1 1 1 1 Handle 349961102 1 1 1 1 Operating Mechanism 193455001 1 1 1 1 Shaft 349961301 1 1 1 1 Shaft- Mod 349962242 1 1 1 1 Ground Lug 349938002 1 1 1 1 Switch- 800A 1, 4 193438201 1 1 1 1 Handle 349961102 1 1 1 1 Operating Mechanism 193455001 1 1 1 1 Shaft 349961301 1 1 1 1 Shaft- Mod 349962242 1 1 1 1 Ground Lug 349938003 1 1 1 1 Switch- 1000A 1, 4 193438206 1 1 1 1 Handle 349961102 1 1 1 1 Operating Mechanism 193455001 1 1 1 1 Shaft 349961301 1 1 1 1 Shaft- Mod 349962242 1 1 1 1 Ground Lug 349938003 1 1 1 1

Power Panel- Power Blocks continued, Receptacle, Disconnect Switch DS1

1 Any of the listed Disconnects may be used, depending on unit options. Check installed part to verify, or contact Daikin Applied with unit serial and/or GO number to ensure correct replacement is selected.

2 The 600A Switch listed is used on units with one Disconnect OR two Disconnects EH/balance of unit (Code 11= A2, B2). 3 If unit has two Disconnects where the second Disconnect controls the fans (Code 11= C2) OR 3 Disconnects (Code 11= D2) then use

Switch p/n 193438002, Handle Kit p/n 193437901, Shaft p/n 349962233, and Ground Lug p/n 349938002. 4 Note that the original Disconnect is obsolete. Due to dimensional differences minor field modifications may be required for proper

installation.

Section N- Main Control BoxPower Panel: (03/2013 & Earlier)

Components, Continued

Page 181: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 181

Sch. Part Part Voltage Sym. Description Number 208V 230V 460V 575V Disconnect Switch, continued DS1 Disconnect Switch- Main Electric Heat (Code 04= E) units Switch- 100A 1 349935121 1 1 1 1 Handle Kit 349935521 1 1 1 1 Shaft 349962204 1 1 1 1 Ground Lug 349938001 1 1 1 1 Load Lug 349956101 1 1 1 1 Cover- Load Lug 349957003 1 1 1 1 Switch- 150A 1 349935122 1 1 1 1 Handle Kit 349935532 1 1 1 1 Shaft 349962205 1 1 1 1 Ground Lug 349938001 1 1 1 1 Load Lug 349956202 1 1 1 1 Cover- Load Lug 349957001 1 1 1 1 Switch- 250A 1 349935222 1 1 1 1 Handle Kit 349935532 1 1 1 1 Shaft 349962205 1 1 1 1 Ground Lug 349938001 1 1 1 1 Load Lug 349956302 1 1 1 1 Cover- Load Lug 349957002 1 1 1 1 Switch- 400A 1 349935325 1 1 1 1 Handle Kit 349935621 1 1 1 1 Shaft 349962206 1 1 1 1 Ground Lug 349938002 1 1 1 1 Switch- 600A 1, 2, 3, 4 193438205 1 1 1 1 Handle 349961102 1 1 1 1 Operating Mechanism 193455001 1 1 1 1 Shaft 349961301 1 1 1 1 Shaft- Mod 349962242 1 1 1 1 Ground Lug 349938002 1 1 1 1 Switch- 800A 1, 4 193438201 1 1 1 1 Handle 349961102 1 1 1 1 Operating Mechanism 193455001 1 1 1 1 Shaft 349961301 1 1 1 1 Shaft- Mod 349962242 1 1 1 1 Ground Lug 349938003 1 1 1 1 Switch- 1000A 1, 4 193438206 1 1 1 1 Handle 349961102 1 1 1 1 Operating Mechanism 193455001 1 1 1 1 Shaft 349961301 1 1 1 1 Shaft- Mod 349962242 1 1 1 1 Ground Lug 349938003 1 1 1 1

Section N- Main Control BoxPower Panel: (03/2013 & Earlier)

Components, ContinuedPower Panel- Disconnect Switch DS1 continued

1 Any of the listed Disconnects may be used, depending on unit options. Check installed part to verify, or contact Daikin Applied with unit serial and/or GO number to ensure correct replacement is selected.

2 The 600A Switch listed is used on units with one Disconnect OR two Disconnects EH/balance of unit (Code 11= A2, B2). 3 If unit has two Disconnects where the second Disconnect controls the fans (Code 11= C2) OR 3 Disconnects (Code 11= D2) then use

Switch p/n 193438002, Handle Kit p/n 193437901, Shaft p/n 349962233, and Ground Lug p/n 349938002. 4 Note that the original Disconnect is obsolete. Due to dimensional differences minor field modifications may be required for proper

installation.

Page 182: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 182

Sch. Part Part Voltage Sym. Description Number 208V 230V 460V 575V Disconnect Switch, continued DS2 Disconnect Switch- SAF/RAF Code 11= C2, D2 Switch- 100A 1 349935121 1 1 1 1 Handle Kit 349935521 1 1 1 1 Shaft 349962204 1 1 1 1 Ground Lug 349938001 1 1 1 1 Load Lug 349956101 1 1 1 1 Cover- Load Lug 349957003 1 1 1 1 Switch- 150A 1 349935122 1 1 1 1 Handle Kit 349935532 1 1 1 1 Shaft 349962205 1 1 1 1 Ground Lug 349938001 1 1 1 1 Load Lug 349956202 1 1 1 1 Cover- Load Lug 349957001 1 1 1 1 Switch- 250A 1 349935222 1 1 1 1 Handle Kit 349935532 1 1 1 1 Shaft 349962205 1 1 1 1 Ground Lug 349938001 1 1 1 1 Load Lug 349956302 1 1 1 1 Cover- Load Lug 349957002 1 1 1 1 Switch- 400A 1 349935321 1 1 1 1 Handle Kit 349935621 1 1 1 1 Shaft 349962206 1 1 1 1 Ground Lug 349938002 1 1 1 1 Load Lug 349956401 3 3 3 3 Cover- Load Lug 349957004 1 1 1 1 Circuit Breakers CB10 Circuit Breaker CB20 Circuit Breaker- Return Fan Motor HP= 2, 3 349939621 1 1 1 Motor HP= 2, 3, 5, 7.5, 10 349939601 1 Motor HP= 5 349939622 1 1 Motor HP= 5, 7.5 349939621 1 Motor HP= 7.5 349939624 1 1 Motor HP= 10 349939626 1 1 Motor HP= 10 349939622 1 Motor HP= 15 349939629 1 1 Motor HP= 15 349939624 1 Motor HP= 15, 20 349939604 1 Motor HP= 20 349939631 1 Motor HP= 20 349939630 1 Motor HP= 20, 25 349939626 1 Motor HP= 25 349939632 1 Motor HP= 25 349939631 1 Motor HP= 25, 30 349939606 1

Power Panel- Disconnect Switch DS2, Circuit Breakers CB10, 20

Section N- Main Control BoxPower Panel: (03/2013 & Earlier)

Components, Continued

1 Any of the listed Disconnects may be used, depending on unit options. Check installed part to verify, or contact Daikin Applied with unit serial and/or GO number to ensure correct replacement is selected.

Page 183: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 183

Sch. Part Part Voltage Sym. Description Number 208V 230V 460V 575V Circuit Breakers, Continued CB10 Circuit Breaker CB20 Circuit Breaker- Return Fan Motor HP= 30 349939701 1 Motor HP= 30 349939633 1 Motor HP= 30 349939628 1 Motor HP= 40 349939703 1 1 Motor HP= 40 349939630 1 Motor HP= 40 349939608 1 Motor HP= 50 349939631 1 Motor HP= 50 349939610 1

CB60 Circuit Breaker- Heat Recovery Wheel Code 24= F 349939621 1 1 1 Circuit Breaker- Heat Recovery Wheel Code 24= F 349939601 1

PL1- 43 Plugs 3 4 4 Pin Plug 349930201 varies varies varies varies 5 6 Pin Plug 349930403 varies varies varies varies 6 12 Pin Plug 349930405 varies varies varies varies 7 3 Pin Cap Kit 349930501 varies varies varies varies 8 6 Pin Cap Kit 349930503 varies varies varies varies 9 9 Pin Cap Kit 349930504 varies varies varies varies 10 15 Pin Cap Kit 349930506 varies varies varies varies

Power Panel- Circuit Breakers CB10, 20 continued, Plugs

3 All possible Plugs used are listed. Check actual unit to verify which Plug is required.4 Used for PL1, PL, 2, PL3, PL4, PL5, PL6, PL22,PL23, PL24, PL37, PL38.5 Used with Strain Relief (p/n 300041173) & 6 pin Cap Kit (p/n 349930503). Used for PL20, PL21.6 Used for PL11, PL12, PL25, PL26, PL27, PL28, PL29, PL30 (PL11 & 12 also use Strain Relief p/n 300041175 & Cap Kit p/n

349930505).7 Used for PL16, PL17, PL31, PL32, PL33, PL34, PL39, PL40, PL41, PL42. 8 Used for PL9, PL10. 9 Used for PL18, PL19, PL35, PL36, PL43. 10 Used for PL7, PL8.

Section N- Main Control BoxPower Panel: (03/2013 & Earlier)

Components, Continued

Page 184: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 184

Section N- Main Control BoxPower Panel: (03/2013 & Earlier)

Supply MMP10 & M10 Fan ContactorReturn MMP20 & M20 Fan Contactor

Diagrams

MMP

LinkContactor

Front Mtd.Contact

3

3B1

3E

MMP10 & M10 Link DetailMMP20 & M20 Link Detail

2, 3, 5, 7.5 HP Motors- All Voltages10 HP Motor- 230/460/575V15, 20 HP Motor- 460/575V

25, 30 HP Motors- 575V

NOTE: The diagrams show all possible parts. Not every part shown applies to every unit size/voltage combination.

MMP10 & M10 Link DetailMMP20 & M20 Link Detail

10HP Motor- 208V15HP Motor- 208/230V

20 HP Motors- 208/230V25 HP Motors- 230/460V

30 HP Motors- 460V40 HP Motors- 460/575V50 HP Motors- 460/575V

MMP10 & M10 Link DetailMMP20 & M20 Link Detail

30 HP Motors- 208V40 HP Motors- 208/230V

50 HP Motors- 230VV

Contactor 1

MMP 3

Trip Ind.Interlock 3F

Lug 3G Lug3G

MMP3

Trip Ind.Interlock

3F

Contactor

1

MMP10 & M10 Link Detail50 HP Motors- 208V

MMPFront Mounted Aux. Contact

3E

Contactor

1

3 MMP 3

Contactor

1

Trip Indicator

Alarm3F

Lug 3G

MMP10 & M10 Link DetailMMP20 & M20 Link Detail

25 HP Motors- 208V30 HP Motors- 230V

Page 185: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 185

Section N- Main Control BoxPower Panel: (03/2013 & Earlier)

Supply and Return Fan Contactors Components

Voltage Ref. Sch. Part Part No. Sym. Description Number 1 M20 Contactor- Return Fan 349932121 1 1 1 1 3 MMP20 MMP- Return Fan 349934050 1 MMP- Return Fan 349934049 1 MMP- Return Fan 349934048 1 MMP- Return Fan 349934047 1 3B Link 349932922 1 1 1 1 3E Front Mtd. Aux. Contact- 1NO OR 1NC 349933821 1 1 1 1

208V

230V

460V

575V

2 HP Motor- Code 22= G*Y

Voltage Ref. Sch. Part Part No. Sym. Description Number 1 M10, 20 Contactor- Supply (M10) OR Return (M20) Fan 349932122 1 1 Contactor- Supply (M10) OR Return (M20) Fan 349932121 1 1 3 MMP10,20 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934051 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934050 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934049 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934048 1 3B Link 349932922 1 1 1 1 3E Front Mtd. Aux. Contact- 1NO OR 1NC 349933821 1 1 1 1

208V

230V

460V

575V

3 HP Motor- Code 22 OR 32= H*Y

Voltage Ref. Sch. Part Part No. Sym. Description Number 1 M10, 20 Contactor- Supply (M10) OR Return (M20) Fan 349932123 1 1 Contactor- Supply (M10) OR Return (M20) Fan 349932121 1 1 3 MMP10,20 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934052 1 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934050 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934049 1 3B Link 349932922 1 1 1 1 3E Front Mtd. Aux. Contact- 1NO OR 1NC 349933821 1 1 1 1

208V

230V

460V

575V

5 HP Motor- Code 22 OR 32= J*Y

Page 186: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 186

Voltage Ref. Sch. Part Part No. Sym. Description Number 1 M10, 20 Contactor- Supply (M10) OR Return (M20) Fan 349932321 1 1 Contactor- Supply (M10) OR Return (M20) Fan 349932122 1 Contactor- Supply (M10) OR Return (M20) Fan 349932121 1 3 MMP10,20 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934054 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934053 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934051 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934050 1 3B Link 349932922 1 1 1 1 3E Front Mtd. Aux. Contact- 1NO OR 1NC 349933821 1 1 1 1

208V

230V

460V

575V

7.5 HP Motor- Code 22 OR 32= K*Y

Voltage Ref. Sch. Part Part No. Sym. Description Number 1 M10, 20 Contactor- Supply (M10) OR Return (M20) Fan 349932521 1 Contactor- Supply (M10) OR Return (M20) Fan 349932322 1 Contactor- Supply (M10) OR Return (M20) Fan 349932123 1 Contactor- Supply (M10) OR Return (M20) Fan 349932122 1 3 MMP10,20 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934147 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934055 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934052 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934051 1 3B Link 349932922 1 1 1 3E Front Mtd. Aux. Contact- 1NO OR 1NC 349933821 1 1 1 1

208V

230V

460V

575V

10 HP Motor- Code 22 OR 32= L*Y

Voltage Ref. Sch. Part Part No. Sym. Description Number 1 M10, 20 Contactor- Supply (M10) OR Return (M20) Fan 349932522 1 1 Contactor- Supply (M10) OR Return (M20) Fan 349932321 1 Contactor- Supply (M10) OR Return (M20) Fan 349932123 1 3 MMP10,20 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934148 1 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934053 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934052 1 3B Link 349932922 1 1 3E Front Mtd. Aux. Contact- 1NO OR 1NC 349933821 1 1 1 1

208V

230V

460V

575V

15 HP Motor- Code 22 OR 32= M*Y

Section N- Main Control BoxPower Panel: (03/2013 & Earlier)

Supply and Return Fan Contactors Components, Continued

Page 187: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 187

Voltage Ref. Sch. Part Part No. Sym. Description Number 1 M10, 20 Contactor- Supply (M10) OR Return (M20) Fan 349932523 1 1 Contactor- Supply (M10) OR Return (M20) Fan 349932322 1 Contactor- Supply (M10) OR Return (M20) Fan 349932321 1 3 MMP10,20 MMP- Supply (MMP10) OR Return (MMP20) Fan 34993414 1 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934055 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934053 1 3B Link 349932922 1 1 3E Front Mtd. Aux. Contact- 1NO OR 1NC 349933821 1 1 1 1

208V

230V

460V

575V

20 HP Motor- Code 22 OR 32= N*Y

Voltage Ref. Sch. Part Part No. Sym. Description Number 1 M10, 20 Contactor- Supply (M10) OR Return (M20) Fan 349932621 1 1 Contactor- Supply (M10) OR Return (M20) Fan 349932521 1 Contactor- Supply (M10) OR Return (M20) Fan 349932322 1 3 MMP10,20 MMP- Supply (MMP10) OR Return (MMP20) Fan 349938606 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934149 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934147 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934054 1 3B Link 349932922 1 3E Front Mtd. Aux. Contact- 1NO OR 1NC 349933821 1 1 1 3F Trip Indicator Interlock 349938701 1 3G Lug (3 per kit) 349938801 2

208V

230V

460V

575V

25 HP Motor- Code 22 OR 32= P*Y

Section N- Main Control BoxPower Panel: (03/2013 & Earlier)

Supply and Return Fan Contactors Components, Continued

Page 188: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 188

Voltage Ref. Sch. Part Part No. Sym. Description Number 1 M10, 20 Contactor- Supply (M10) OR Return (M20) Fan 349932721 1 Contactor- Supply (M10) OR Return (M20) Fan 349932621 1 Contactor- Supply (M10) OR Return (M20) Fan 349932521 1 Contactor- Supply (M10) OR Return (M20) Fan 349932322 1 3 MMP10,20 MMP- Supply (MMP10) OR Return (MMP20) Fan 349938606 1 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934147 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934055 1 3B Link 349932922 1 3E Front Mtd. Aux. Contact- 1NO OR 1NC 349933821 1 1 3F Trip Indicator Interlock 349938701 1 1 3G Lug (3 per kit) 349938801 2 2

208V

230V

460V

575V

30 HP Motor- Code 22 OR 32= Q*Y

Voltage Ref. Sch. Part Part No. Sym. Description Number 1 M10 Contactor- Supply Fan 349932722 1 Contactor- Supply Fan 349932721 1 Contactor- Supply Fan 349932522 1 1 3 MMP10 Motor Protector- Supply Fan 349938607 1 1 Motor Protector- Supply Fan 349934148 1 1 3E Front Mtd. Aux. Contact- 1NO OR 1NC 349933821 1 1 3F Trip Indicator Interlock 349938701 1 1 3G Lug (3 per kit) 349938801 11 11

208V

230V

460V

575V

40 HP Motor- Code 32= R*Y

Voltage Ref. Sch. Part Part No. Sym. Description Number 1 M10 Contactor- Supply Fan 349932702 1 Contactor- Supply Fan 349932722 1 Contactor- Supply Fan 349932621 1 Contactor- Supply Fan 349932523 1 3 MMP10 Motor Protector- Supply Fan 349938607 1 1 Motor Protector- Supply Fan 349934149 1 1 3E Front Mtd. Aux. Contact- 1NO OR 1NC 349933821 1 1 3F Trip Indicator Interlock 349938701 1 1 3G Lug (3 per kit) 349938801 12 12

208V

230V

460V

575V

50 HP Motor- Code 32= S*Y

1 Also requires 3 ring terminals.

2 Also requires 3 ring terminals.

Section N- Main Control BoxPower Panel: (03/2013 & Earlier)

Supply and Return Fan Contactors Components, Continued

Page 189: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 189

Section N- Main Control BoxPower Panel

Compressor MMP1 thru 4 and Contactor M1 thru 4: (03/2013 & Earlier)Unit Size 045D

MMP

Contactor1

3

MMP1- 4 & M1- 4 Contactor Link Detail208/230V

045

Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts 1 M1- 4 Contactor- Compressor 1 50A 193426822 4 M1- 4 Contactor- Compressor 25A 349932321 4 4

Compressor MMP’s & Parts 3 MMP1- 4 Manual Motor Protector- Compressor 349934149 4 Manual Motor Protector- Compressor 349934053 4 Manual Motor Protector- Compressor 349934052 4

3B Link 349932922 4 4 3E Front Mtd. Aux. Contact- 1NO OR 1NC 349933821 4 4 4

208/

230V

460V

575V

MMP1- 4 & M1- 4 Contactor Link Detail460/575V

MMP 3

Link 3B

Contactor 1

1 In mid 2010 the original cabled Contactor became obsolete and no longer available. The replacement Contactor listed mounts directly to the MMP as shown in the above diagram. When replacing ANY part of an old assembly, a new Contactor and MMP MUST be ordered as new and old parts are not interchangeable.

Front Mounted Contact

3E

3EFront Mounted Contact

Page 190: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 190

Section N- Main Control BoxPower Panel

Compressor MMP1 thru 4 and Contactor M1 thru 4: (03/2013 & Earlier)Unit Sizes 050, 051D

MMP3E

Contactor1

3

050, 051

Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts 1 M1- 4 Contactor- Compressor 1 65A 193426823 4 M1- 4 Contactor- Compressor 25A 349932321 4 4

Compressor MMP’s & Parts 3 MMP1- 4 Manual Motor Protector- Compressor 349934149 4 Manual Motor Protector- Compressor 349934053 4 Manual Motor Protector- Compressor 349934052 4 3B Link 349932922 4 4

3E Front Mtd. Aux. Contact- 1NO OR 1NC 349933821 4 4 4

208/

230V

460V

575V

Front Mounted Contact

MMP1- 4 & M1- 4 Contactor Link Detail460/575V

Link 3B

MMP1- 4 & M1- 4 Contactor Link Detail208/230V

MMP 3

Contactor 1

Front Mounted Contact

3E

1 In mid 2010 the original cabled Contactor became obsolete and no longer available. The replacement Contactor listed mounts directly to the MMP as shown in the above diagram. When replacing ANY part of an old assembly, a new Contactor and MMP MUST be ordered as new and old parts are not interchangeable.

Page 191: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 191

Section N- Main Control BoxPower Panel

Compressor MMP1 thru 4 and Contactor M1 thru 4: (03/2013 & Earlier)Unit Sizes 060- 063D

060- 063

Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts 1 M1- 4 Contactor- Compressor 1 65A 193426823 4 M1- 4 Contactor- Compressor 32A 349932322 4 4

Compressor MMP’s & Parts 3 MMP1- 4 Manual Motor Protector- Compr. 349934149 4 Manual Motor Protector- Compr. 349934055 4 Manual Motor Protector- Compr. 349934053 4

3B Link 349932922 4 4

3E Front Mtd. Aux. Contact- 1NO OR 1NC 349933821 4 4 4

208/

230V

460V

575V

MMP3E

Contactor1

3

Front Mounted Contact

MMP1- 4 & M1- 4 Contactor Link Detail460/575V

Link 3B

MMP1- 4 & M1- 4 Contactor Link Detail208/230V

MMP 3

Contactor 1

Front Mounted Contact

3E

1 In mid 2010 the original cabled Contactor became obsolete and no longer available. The replacement Contactor listed mounts directly to the MMP as shown in the above diagram. When replacing ANY part of an old assembly, a new Contactor and MMP MUST be ordered as new and old parts are not interchangeable.

Page 192: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 192

Section N- Main Control BoxPower Panel

Compressor MMP1 thru 4 and Contactor M1 thru 4: (03/2013 & Earlier)Unit Size 068D

068

Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts 1 M1- 4 Contactor- Compressor 80A 349932621 4 M1- 4 Contactor- Compressor 1 65A 193426823 4 M1- 4 Contactor- Compressor 1 40A 193426821 4 4

Compressor MMP’s & Parts 3 MMP1- 4 Manual Motor Protector- Compr. 349938606 4 Manual Motor Protector- Compr. 349934149 4 Manual Motor Protector- Compr. 349934055 4 4

3E Front Mtd. Aux. Contact- 1NO OR 1NC 349933821 4 4 4 Front Mounted Contact- 1NO 349938701 4 3F Lug Kit (3 lugs per kit) 349938801 8

208V

230V

460V

575V

MMP1- 4 & M1- 4 Contactor Link Detail208V

Front Mount-ed Contact 1A

Contactor 1

MMP 3

Front Mounted Contact 3E

Lug Kit 3F

MMP 3

Contactor 1

Front Mounted Contact

3E

MMP1- 4 & M1- 4 Contactor Link Detail230/460/575V

1 In mid 2010 the original cabled Contactor became obsolete and no longer available. The replacement Contactor listed mounts directly to the MMP as shown in the above diagram. When replacing ANY part of an old assembly, a new Contactor and MMP MUST be ordered as new and old parts are not interchangeable.

Page 193: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 193

Section N- Main Control BoxPower Panel

Compressor MMP1 thru 6 and Contactor M1 thru 6: (03/2013 & Earlier)Unit Sizes 070, 071D

070, 071

Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts 1 M1- 6 Contactor- Compressor 1 50A 193426822 6 M1- 6 Contactor- Compressor 25A 349932321 6 6

Compressor MMP’s & Parts 3 MMP1- 6 Manual Motor Protector- Compr. 349934148 6 Manual Motor Protector- Compr. 349934053 6 Manual Motor Protector- Compr. 349934052 6

3B Link 349932922 6 6

3E Front Mtd. Aux. Contact- 1NO OR 1NC 349933821 6 6 6

208/

230V

460V

575V

MMP3E

Contactor1

3

Front Mounted Contact

MMP1- 6 & M1- 6 Contactor Link Detail460/575V

Link 3B

MMP1- 4 & M1- 4 Contactor Link Detail208/230V

MMP 3

Contactor 1

Front Mounted Contact

3E

1 In mid 2010 the original cabled Contactor became obsolete and no longer available. The replacement Contactor listed mounts directly to the MMP as shown in the above diagram. When replacing ANY part of an old assembly, a new Contactor and MMP MUST be ordered as new and old parts are not interchangeable.

Page 194: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 194

Section N- Main Control BoxPower Panel

Compressor MMP1 thru 6 and Contactor M1 thru 6: (03/2013 & Earlier)Unit Size 075D 2

075

Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts 1 M1- 6 Contactor- Compressor 1 65A 193426823 6 Contactor- Compressor 25A 349932321 6 6

1B Spacer 349906501 6 6

Compressor MMP’s & Parts 3 MMP1- 6 Manual Motor Protector- Compr. 349934149 6 Manual Motor Protector- Compr. 349934053 6 Manual Motor Protector- Compr. 349934052 6

3B Link 349932922 6 6

3E Front Mtd. Aux. Contact- 1NO OR 1NC 349933821 6 6 6

208/

230V

460V

575V

MMP3E

Contactor1

3

Front Mounted Contact

MMP1- 6 & M1- 6 Contactor Link Detail460/575V

Link 3B

MMP1- 4 & M1- 4 Contactor Link Detail208/230V

MMP 3

Contactor 1

Front Mounted Contact

3E

1 In mid 2010 the original cabled Contactor became obsolete and no longer available. The replacement Contactor listed mounts directly to the MMP as shown in the above diagram. When replacing ANY part of an old assembly, a new Contactor and MMP MUST be ordered as new and old parts are not interchangeable.

2 Note that Unit Size 074D uses Inverter Compressors only. Refer to form 7000513.

Spacer1B

Page 195: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 195

Section N- Main Control BoxPower Panel

Compressor MMP1 thru 6 and Contactor M1 thru 6: (03/2013 & Earlier)Unit Size 079D

079

Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts 1 M1, 3, 5 Contactor- Compressor, Cir. # 1 1 65A 193426823 3 Contactor- Compressor, Cir. # 1 25A 349932321 3 3 1 M2, 4, 6 Contactor- Compressor, Cir. # 2 65A 193426823 3 Contactor- Compressor, Cir. # 2 25A 349932322 3 3 1B Spacer 349906501 6 6

Compressor MMP’s & Parts 3 MMP1, 3, 5 Manual Motor Protector- Compr., Cir. # 1 349934149 3 Manual Motor Protector- Compr., Cir. # 1 349934053 3 Manual Motor Protector- Compr., Cir. # 1 349934052 3 3 MMP2, 4, 6 Manual Motor Protector- Compr., Cir. # 2 349934149 3 Manual Motor Protector- Compr., Cir. # 2 349934055 3 Manual Motor Protector- Compr., Cir. # 2 349934053 3 3B Link 349932922 6 6 3E Front Mtd. Aux. Contact- 1NO OR 1NC 349933821 6 6 6

208/

230V

460V

575V

MMP3E

Contactor1

3

Front Mounted Contact

MMP1- 6 & M1- 6 Contactor Link Detail460/575V

Link 3B

MMP1- 4 & M1- 4 Contactor Link Detail208/230V

MMP 3

Contactor 1

Front Mounted Contact3E

1 In mid 2010 the original cabled Contactor became obsolete and no longer available. The replacement Contactor listed mounts directly to the MMP as shown in the above diagram. When replacing ANY part of an old assembly, a new Contactor and MMP MUST be ordered as new and old parts are not interchangeable.

Spacer1B

Page 196: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 196

045- 060 062- 071 075- 079 Ref. Sch. Part Part No. Symbol Description Number Cond. Fan Contactors 7 M11- 24 Contactor- Cond. Fan 349932121 4 4 4 6 6 6 8 8 8 7A Spacer 349906501 4 4 4 6 6 6 8 8 8

Fan MMP’s & Parts 8 MMP11 Manual Motor Protector 349934049 1 1 1 Manual Motor Protector 349934048 1 1 1 Manual Motor Protector 349934047 1 1 Manual Motor Protector 349934051 1 MMP12 Manual Motor Protector 349934049 1 1 Manual Motor Protector 349934048 1 1 Manual Motor Protector 349934047 1 1 MMP13 Manual Motor Protector 349934049 1 1 Manual Motor Protector 349934048 1 1 Manual Motor Protector 349934047 1 Manual Motor Protector 349934051 1 MMP21 Manual Motor Protector 349934049 1 1 1 Manual Motor Protector 349934048 1 1 1 Manual Motor Protector 349934047 1 1 Manual Motor Protector 349934051 1 MMP22 Manual Motor Protector 349934049 1 1 Manual Motor Protector 349934048 1 1 Manual Motor Protector 349934047 1 1 MMP23 Manual Motor Protector 349934049 1 1 Manual Motor Protector 349934048 1 1 Manual Motor Protector 349934047 1 Manual Motor Protector 349934051 1 8B Link- MMP 349932922 4 4 4 6 6 6 4 4 4 8C Bus Bar 349934311 4 4 4

208/

230V

460V

575V

208/

230V

460V

575V

208/

230V

460V

575V

Section N- Main Control BoxPower Panel

Condenser Fan Contactors, MMPs, & FusingFanTrol Units Code 47= 1, 3: (03/2013 & Earlier)

MMP

Link

Contactor

8B

7

8 Link 8B

Contactor 7

Bus Bar

8C

8MMP

One Contactor Arrangement

Two Contactor ArrangementSpacer7A

Spacer7A

Page 197: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 197

Section N- Main Control BoxPower Panel

Condenser Fan Contactors, MMPs, & Fusing, ContinuedSpeedTrol Units Code 47= 2, 4: (03/2013 & Earlier)

Components

MMP & Contactors Detail

One Contactor Arrangement Two Contactor Arrangement

045- 060 062- 071 075- 079 Ref. Sch. Part Part No. Symbol Description Number Fan Contactor & Spacer 7 M12- 14 M22- 24 Contactor 349932121 2 2 2 4 4 4 6 6 6 7A Spacer 349906501 2 2 2 4 4 4 6 6 6 Fan MMP’s & Parts 8 MMP12 Manual Motor Protector 349934049 1 1 1 Manual Motor Protector 349934047 1 1 1 1 1 1 MMP13 Manual Motor Protector 349934049 1 1 1 Manual Motor Protector 349934047 1 1 Manual Motor Protector 349934050 1 MMP22 Manual Motor Protector 349934049 1 1 1 Manual Motor Protector 349934047 1 1 1 1 1 1 MMP23 Manual Motor Protector 349934049 1 1 1 Manual Motor Protector 349934047 1 1 Manual Motor Protector 349934050 1 8B Link- MMP 349932922 2 2 2 4 4 4 4 4 4 8C Bus Bar 349934311 2 2 2

SpeedTrol Fusing 9 F11, 21 Fuse Block 023780232 2 2 2 2 2 2 2 2 2 9B Fuse Cover/Puller 349938227 6 6 6 6 6 6 6 6 6 9A F11, 21 Fuse- SpeedTrol 1 6 6 6 Fuse- SpeedTrol 1 6 6 6 Fuse- SpeedTrol 1 6 6 6 9C DIN Rail Adapter 349938412 4 4 4 4 4 4 4 4 4

208/

230V

460V

575V

208/

230V

460V

575V

208/

230V

460V

575V

SpeedTrol Fuses

F11 OR F21

MMP

Link

Contactor

8B

7

8

Spacer7A

Link 8B

Contactor 7

Bus Bar

8C

8MMP

Spacer7A

Fuse Block

Puller

Fuse

9B

9A 9

Adapter

9C

1 Contact Daikin Applied with model and serial number information so that the correct part can be identified

Page 198: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 198

MMP

Link

Contactor

8

8B

7

1 Units With No Frost Protection (Code 24= Y).

Unit Voltage

Ref. Sch. Part Part No. Sym. Description Number Heat Wheel Contactor 7 M60 Contactor 349932121 1 1 1 Heat Wheel MMP’s & Parts 8 MMP60 Manual Motor Protector 349934049 1 Manual Motor Protector 349934047 1 1 8B Link- MMP 349932922 1 1 1

208/

230V

460V

575V

Section N- Main Control BoxPower Panel

Heat Recovery Wheel MMP60 and Contactor M60: (03/2013 & Earlier)Components 1

Page 199: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 199

Section N- Main Control BoxPower Panel: (04/2013 & Later)

Diagrams 1

1 The above diagram shows a typical Power Panel layout and is to be used for reference only. Specific unit configuration may differ depending upon unit size and options selected.

PL1

- PL4

3 Pl

ugs

See

Con

trol

Pan

el See Control Panel

Page 200: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 200

Sch. Part Part Voltage Sym. Description Number 208V 230V 460V 575V Terminal Blocks TB2,3,4,7 Terminal Block 349930641 1 1 1 1

Transformer- Main Control & Fusing T1 Transformer Electric, Hydronic, No Heat Code 04= E,S,W,Y Units without UV Lights Code 23= Y**** ALL Sizes 1000VA 099477205 1 ALL Sizes 1000VA 099477105 1 1 ALL Sizes 1000VA 099477305 1 Units with UV Lights Code 23= U**** ALL Sizes 1500VA 099477206 1 ALL Sizes 1500VA 099477106 1 1 ALL Sizes 1500VA 099477306 1 Gas Heat Code 04= A Units without UV Lights Code 23= Y**** ALL Sizes 1500VA 099477206 1 ALL Sizes 1500VA 099477106 1 1 ALL Sizes 1500VA 099477306 1 Units with UV Lights Code 23= U**** ALL Sizes 2000VA 099477207 1 ALL Sizes 2000VA 099477107 1 1 ALL Sizes 2000VA 099477307 1 N/S Cover Kit, Terminal 099477602 1 1 1 1 N/S Cover Kit, Fuseholder 099477401 1 1 1 1 Fuses- T1 Transformer FU1A, B Fuse- T1 Transformer, Primary 2 2 2 2 2 FU1C Fuse- T1 Transformer, Secondary 2 1 1 1 1

Power Panel- Terminal Blocks, T1 Transformer & Fusing

Section N- Main Control BoxPower Panel: (04/2013 & Later)

Components

N/S= Not shown on diagram. 1 Varies depending on unit options. Part number is for one individual section. Ground block is p/n 349930647. When required TB2, 3,

4, 7 use Jumper p/n 349930922 (2 pole), 349930923 (3 pole), 349930924 (4 pole), 349930925 (5 pole).2 Contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified.

Page 201: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 201

Sch. Part Part Voltage Sym. Description Number 208V 230V 460V 575V Fuses F2,F3, F5 Fuses Fuse Block 023780223 1/fuse 1/fuse 1/fuse 1/fuse Fuse Cover 349938227 1/fuse 1/fuse 1/fuse 1/fuse F2 Fuse- 2000+VA transformer 349937035 1 1 1 1 F3 Fuse- Blower Motor Code 04= A 349937035 1 1 1 1 F5 Fuse- UV Lights Code 17 (2nd digit)= 1- 8 349937032 1 1 1 1 Phase Voltage Monitor Code 17= P,A,C,D,H,J,K PVM1, 2 Phase Voltage Monitor (12/16 & Earlier) 3 112022001 2 2 2 Phase Voltage Monitor (12/16 & Earlier) 3 112022002 2 Phase Voltage Monitor (2/17 & Later) 3 193599301 2 2 2 Phase Voltage Monitor (2/17 & Later) 3 193599303 2 - Socket, PVM (2/17 & Later) 3 193599401 2 2 2 2 Ground Fault Protection Code 17= G,B,C,D,K GFR1, 2 Ground Fault Relay- SPDT 349937502 1 1 1 1 GFS1, 2 Ground Fault Sensor 349937407 1 1 1 1 Power Blocks PB1, PB2 Power Block- Main 2 Code 11= P1, Q1 Power Block, Non- Electric Heat Units- 175A 1 030372776 1 1 1 1 Power Block, Electric Heat Units- 175A 1 030372780 1 1 1 1 Lug- 175A Block 349938001 1 1 1 1 Power Block, Non- Electric Heat Units- 255A 1 030372778 1 1 1 1 Lug- 255A Block 349938001 1 1 1 1 Power Block, Non- Electric Heat Units- 380A 1 030372779 1 1 1 1 Power Block, Electric Heat- 380A 1 030372782 1 1 1 1 Lug- 380A Block 349938001 1 1 1 1 Power Block, Non- Electric Heat Units- 620A 1 030372702 1 1 1 1 Cover- 620A Block 349938345 3 3 3 3 Lug- 620A Block 349938002 1 1 1 1 Power Block, Non- Electric Heat Units- 760A 1 030372760 1 1 1 1 Power Block, Electric Heat Units, 208/230V- 760A 1 030372772 1 1 Power Block, Electric Heat Units, 460/575V- 760A 1 030372760 1 1 Cover- 760A Block 349938345 3 3 3 3 Lug- 760A Block 349938003 1 1 1 1 Power Block, Non- Electric Heat Units- 840A 1 030372724 1 1 1 1 Cover- 840A Block 349938345 3 3 3 3 Lug- 840A Block 349938003 1 1 1 1 PB11 Power Block- Power Distribution Power Block- 420A 1 030372785 1 1 1 1 Power Block- 760A 1 030372721 1 1 1 1 Cover- 760A Block 349938345 1 1 1 1 PB12 Power Block- Power Distribution Code 04= E 20, 40 KW Electric Heat 030372777 1 1 1 1 60, 80, 100, 120 KW Electric Heat 030372785 1 1 60, 80, 100, 120 KW Electric Heat 030372777 1 1 160 KW Electric Heat 030372785 1 1 1 1 200, 240 KW Electric Heat 030372785 1 1

Power Panel- Fusing, Phase Protection, Ground Fault, Power Blocks

1 Any of the listed parts may be used, depending on unit options. Check installed part to verify, or contact Daikin Applied with unit serial and/or GO number to ensure correct replacement is selected. PB2 is installed when Code 11= Q1.

2 These power blocks are used on RPS and RDT units. RFS units use the following: 175A p/n 030372777 + Lug p/n 349938302; 310A p/n 030372783 + Lug p/n 349938302; 420A p/n 030372785 + Lug 349938302; 760A p/n 030372721 + Lug p/n 349938003.

3 For units built 1/17 contact Daikin Applied with model and serial number to ensure correct part(s) are identified.

Section N- Main Control BoxPower Panel: (04/2013 & Later)

Components, Continued

Page 202: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 202

Sch. Part Part Voltage Sym. Description Number 208V 230V 460V 575V Power Blocks, continued PB10 Power Block- Supply Fan Code 15= F 030372776 1 1 1 1 PB20 Power Block- Return Fan Code 15= F 030372776 1 1 1 1 Receptacle REC1 Receptacle 039003600 1 1 1 1 PL1- 43 Plugs 1 2 4 Pin Plug 349930201 varies varies varies varies 3 6 Pin Plug 349930403 varies varies varies varies 4 12 Pin Plug 349930405 varies varies varies varies 5 3 Pin Cap Kit 349930501 varies varies varies varies 6 6 Pin Cap Kit 349930503 varies varies varies varies 7 9 Pin Cap Kit 349930504 varies varies varies varies 8 15 Pin Cap Kit 349930506 varies varies varies varies

Power Panel- Power Blocks, continued, Receptacle, Plugs

Section N- Main Control BoxPower Panel: (04/2013 & Later)

Components, Continued

1 All possible Plugs used are listed. Check actual unit to verify which Plug is required.2 Used for PL1, PL, 2, PL3, PL4, PL5, PL6, PL22,PL23, PL24, PL37, PL38.3 Used with strain relief (p/n 300041173) & 6 pin cap kit (p/n 349930503). Used for PL20, PL21.4 Used for PL11, PL12, PL25, PL26, PL27, PL28, PL29, PL30 (PL11 & 12 also use Strain Relief p/n 300041175 & Cap Kit p/n

349930505).5 Used for PL16, PL17, PL31, PL32, PL33, PL34, PL39, PL40, PL41, PL42. 6 Used for PL9, PL10. 7 Used for PL18, PL19, PL35, PL36, PL43. 8 Used for PL7, PL8.

Page 203: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 203

Sch. Part Part Voltage Sym. Description Number 208V 230V 460V 575V Disconnect Switch 1

DS1, 2 Disconnect Switch- Main, RAF & SAF Switch- 100A 193444703 1 1 1 1 Handle 193422102 1 1 1 1 Shaft 2 193596420 1 1 1 1 Switch- 150A 193585101 1 1 1 1 Handle 193422102 1 1 1 1 Mechanism 193550801 1 1 1 1 Shaft 2 193596420 1 1 1 1 Lugs 4 193553301 1 1 1 1 Switch- 250A 193551601 1 1 1 1 Handle 193595701 1 1 1 1 Mechanism 193551001 1 1 1 1 Shaft 3 300049193 1 1 1 1 Lugs 4 193553801 1 1 1 1 Switch- 400A 193551701 1 1 1 1 Handle 193595701 1 1 1 1 Mechanism 193551001 1 1 1 1 Shaft 3 300049193 1 1 1 1 Lugs 4 193554001 1 1 1 1 Switch- 600A 193551801 1 1 1 1 Handle 193595701 1 1 1 1 Mechanism 193551001 1 1 1 1 Shaft 3 300049193 1 1 1 1 Lugs 4 193554101 2 2 2 2 Switch- 800A 193551901 1 1 1 1 Handle 193595701 1 1 1 1 Mechanism 193558201 1 1 1 1 Shaft 3 300049193 1 1 1 1 Lugs 4 193557001 2 2 2 2 Switch- 1000A 193552001 1 1 1 1 Handle 193588001 1 1 1 1 Mechanism 193550801 1 1 1 1 Shaft 3 300049193 1 1 1 1 Lugs 4 193555801 2 2 2 2

Section N- Main Control BoxPower Panel: (04/2013 & Later)

Components, ContinuedPower Panel- Disconnect Switch DS1, 2

1 Disconnects are sized according to various unit specifications. Check installed switch to verify the correct Disconnect size, or contact Daikin Applied with model and serial number information so that the required part(s) can be identified.

2 This Shaft is 14.25” OAL and is designed to be cut to length in the field.3 This Shaft is 7.21” (183mm) OAL and is designed to be cut to length in the field. For a 19.69” (500mm) OAL use p/n 300040299.4 Three Lugs are included with each p/n.

Page 204: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 204

Section N- Main Control BoxPower Panel: (04/2013 & Later)

Supply MMP10 & M10 Fan ContactorReturn MMP20 & M20 Fan Contactor

Diagrams

MMP

3

Link 3B

Contactor

1

Front Mtd.Aux. Contact

2

MMP10 & M10 Link DetailMMP20 & M20 Link Detail

2 HP Motors- All Voltages3, 5 HP Motors- 460/575V

7.5 HP Motors- 575V

NOTE: The diagrams show ALL possible parts. Not every part shown applies to every unit size/voltage combination.

MMP10 & M10 Link DetailMMP20 & M20 Link Detail

3, 5 HP Motors- 208/230V7.5 HP Motors- 208/230/460V10 HP Motors- All Voltages

15, 20 HP Motors- 460V

MMP10 & M10 Link DetailMMP20 & M20 Link Detail

20, 25, 30 HP Motors- 208/230V40 HP Motors- 460V

50 HP Motors- 460/575V

MMP

3

4A4

Contactor

1

MMP

2

Contactor1

3MMP 3

Contactor1

MMP10 & M10 Link DetailMMP20 & M20 Link Detail15 HP Motors- 208/230/575V

20, 40 HP Motors- 575V25, 30 HP Motor- 460/575V

3EPhase Barrier

Spacer3A

3EPhase Barrier

Front Mtd.Aux. Contact

Link 3B

2Front Mtd.

Aux. Contact Link3B

Front Mtd.Aux. Contact

2

Contactor

1

Link 3B

3EPhase Barrier

Overload

TerminalBlock

MMP10 & M10 Link Detail40, 50 HP Motors- 208/230V

3Circuit Breaker

(not shown)

Page 205: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 205

3 HP Motor- Code 22 OR 32= H*Y Voltage Ref. Sch. Part Part No. Sym. Description Number 1 M10, 20 Contactor- Supply (M10) OR Return (M20) Fan 193592005 1 1 Contactor- Supply (M10) OR Return (M20) Fan 193534105 1 1 2 Front Mtd. Aux. Contact- 1NO AND 1NC 193543801 1 1 1 1 3 MMP10, 20 MMP- Supply (MMP10) OR Return (MMP20) Fan 193543007 1 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 193542910 1 1 3A Spacer 193545801 1 1 3B Link 193546001 1 1 Link 193545901 1 1 3E Phase Barrier 193545501 1 1 1 1 N/S CB10, 20 Circuit Breaker- Supply OR Return Fan 15A 193550201 1 FB10, 20 Fuseblock- Supply OR Return Fan 023780232 1 1 1 Fuse- Supply OR Return Fan 15A 349937133 3 Fuse- Supply OR Return Fan 10A 049759816 3 Fuse- Supply OR Return Fan 7A 349937127 3 Fuse Cover/Puller 349938227 2 2 2

208V

230V

460V

575V

N/S= Not Shown on Diagram. 2 1 pc. PER Fuse.

Section N- Main Control BoxPower Panel: (04/2013 & Later)

Supply and Return Fan Contactors, Circuit Breakers, & Fusing Components

Voltage Ref. Sch. Part Part No. Sym. Description Number 1 M20 Contactor- Return Fan 9A 193534106 1 Contactor- Return Fan 7A 193534105 1 1 1 2 Front Mtd. Aux. Contact- 1NO AND 1NC 193543801 1 1 1 1 3 MMP20 MMP- Return Fan 5.5- 8A 193542912 1 MMP- Return Fan 4.5- 6.3A 193542911 1 MMP- Return Fan 2.2- 3.2A 193542908 1 MMP- Return Fan 1.8- 2.5A 193542907 1 3B Link 193545901 1 1 1 1 3E Phase Barrier 193545501 1 1 1 1 N/S CB20 Circuit Breaker- Return Fan 15A 193550201 1 FB20 Fuseblock- Return Fan 023780232 1 1 1 Fuse- Return Fan 10A 049759816 3 Fuse- Return Fan 9A 349937130 3 Fuse- Return Fan 4A 349937123 3 Fuse Cover/Puller- Return Fan 349938227 1 1 1

208V

230V

460V

575V

N/S= Not Shown on Diagram. 1 1 pc. PER Fuse.

2 Horsepower Motor- Code 22= G*Y

Page 206: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 206

Section N- Main Control BoxPower Panel: (04/2013 & Later)

Supply and Return Fan Contactors, Circuit Breakers, & Fusing Components, Continued

Voltage Ref. Sch. Part Part No. Sym. Description Number 1 M10, 20 Contactor- Supply (M10) OR Return (M20) Fan 193537304 1 1 Contactor- Supply (M10) OR Return (M20) Fan 193592005 1 Contactor- Supply (M10) OR Return (M20) Fan 193534106 1 2 Front Mtd. Aux. Contact- 1NO AND 1NC 193543801 1 1 1 1 3 MMP10, 20 MMP- Supply (MMP10) OR Return (MMP20) Fan 193543012 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 193543011 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 193543008 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 193542913 1 3A Spacer 193545801 1 1 1 3B Link 193546001 1 1 1 Link 193545901 1 3E Phase Barrier 193545501 1 1 1 1 N/S CB10, 20 Circuit Breaker- Supply OR Return Fan 15A 193550201 1 FB10, 20 Fuseblock- Supply OR Return Fan 193428502 1 1 Fuseblock- Supply OR Return Fan 023780232 1 Fuse - Supply OR Return Fan 35A 113085249 3 3 Fuse - Supply OR Return Fan 15A 349937133 3 Fuse Cover 193428602 1 1 Fuse Cover/Puller 349938227 2

208V

230V

460V

575V

N/S= Not Shown on Diagram. 2 1 pc. PER Fuse.

7.5 HP Motor- Code 22 OR 32= K*Y

Voltage Ref. Sch. Part Part No. Sym. Description Number 1 M10, 20 Contactor- Supply (M10) OR Return (M20) Fan 193537304 1 Contactor- Supply (M10) OR Return (M20) Fan 193592006 1 Contactor- Supply (M10) OR Return (M20) Fan 193534106 1 Contactor- Supply (M10) OR Return (M20) Fan 193534105 1 2 Front Mtd. Aux. Contact- 1NO AND 1NC 193543801 1 1 1 1 3 MMP10, 20 MMP- Supply (MMP10) OR Return (MMP20) Fan 193543009 1 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 193542912 1 1 3A Spacer 193545801 1 1 3B Link 193546001 1 1 Link 193545901 1 1 3E Phase Barrier 193545501 1 1 1 1 N/S CB10, 20 Circuit Breaker- Supply OR Return Fan 15A 193550201 1 FB10, 20 Fuseblock- Supply OR Return Fan 023780232 1 1 1 Fuse- Supply OR Return Fan 25A 349937136 3 Fuse- Supply OR Return Fan 20A 349937135 3 Fuse- Supply OR Return Fan 10A 049759816 3 Fuse Cover/Puller 349938227 1 1 1

208V

230V

460V

575V

N/S= Not Shown on Diagram. 1 1 pc. PER Fuse.

5 HP Motor- Code 22 OR 32= J*Y

Page 207: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 207

Section N- Main Control BoxPower Panel: (04/2013 & Later)

Supply and Return Fan Contactors, Circuit Breakers, & Fusing Components, Continued

10 HP Motor- Code 22 OR 32= L*Y Voltage Ref. Sch. Part Part No. Sym. Description Number 1 M10, 20 Contactor- Supply (M10) OR Return (M20) Fan 193537305 1 1 Contactor- Supply (M10) OR Return (M20) Fan 193592006 1 Contactor- Supply (M10) OR Return (M20) Fan 193592005 1 2 Front Mtd. Aux. Contact- 1NO AND 1NC 193543801 1 1 1 1 3 MMP10, 20 MMP- Supply (MMP10) OR Return (MMP20) Fan 193543014 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 193543013 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 193543009 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 193543008 1 3A Spacer 193545801 1 1 1 1 3B Link 193546001 1 1 1 1 3E Phase Barrier 193545501 1 1 1 1 N/S AFD10, 20 VFD- Supply OR Return Fan 1 1 1 1 1 N/S CB10, 20 Circuit Breaker- Supply OR Return Fan 15A 193550201 1 FB10, 20 Fuseblock- Supply OR Return Fan 193428502 1 1 Fuseblock- Supply OR Return Fan 023780232 1 Fuse- Supply OR Return Fan 50A 113085252 3 Fuse- Supply OR Return Fan 45A 113085251 3 Fuse- Supply OR Return Fan 20A 349937135 3 Fuse Cover- Supply OR Return Fan 193428602 1 1 Fuse Cover/Puller- Supply Fan 349938227 2

208V

230V

460V

575V

N/S= Not Shown on Diagram. 1 Refer to the Inverter Section for VFD p/ns. Reference Code 15 for Inverter brand supplied.2 1 pc. PER Fuse.

Page 208: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 208

Section N- Main Control BoxPower Panel: (04/2013 & Later)

Supply and Return Fan Contactors, Circuit Breakers, & Fusing Components, Continued

15 HP Motor- Code 22 OR 32= M*Y Voltage Ref. Sch. Part Part No. Sym. Description Number 1 M10, 20 Contactor- Supply (M10) OR Return (M20) Fan 193591602 1 1 Contactor- Supply (M10) OR Return (M20) Fan 193537304 1 Contactor- Supply (M10) OR Return (M20) Fan 193598101 1 2 Front Mtd. Aux. Contact- 1NO AND 1NC 193546201 1 1 1 Front Mtd. Aux. Contact- 1NO AND 1NC 193543801 1 3 MMP10, 20 MMP- Supply (MMP10) OR Return (MMP20) Fan 193543306 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 193543305 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 193543010 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 193543301 1 3A Spacer 193545801 1 3B Link 193547401 1 1 1 Link 193546001 1 3E Phase Barrier 193545501 1 N/S CB10, 20 Circuit Breaker- Supply OR Return Fan 20A 193550202 1 FB10, 20 Fuseblock- Supply OR Return Fan 349964253 1 Fuseblock- Supply OR Return Fan 193428502 1 Fuseblock- Supply OR Return Fan 023780232 1 Fuse - Supply OR Return Fan 70A 113085254 3 Fuse - Supply OR Return Fan 60A 113085253 3 Fuse - Supply OR Return Fan 30A 349937137 3 Fuse Cover 349964263 1 Fuse Cover 193428602 1 Fuse Cover/Puller 349938227 1

208V

230V

460V

575V

N/S= Not Shown on Diagram. 1 1 pc. PER Fuse.

Page 209: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 209

25 HP Motor- Code 22 OR 32= P*Y

Section N- Main Control BoxPower Panel: (04/2013 & Later)

Supply and Return Fan Contactors, Circuit Breakers, & Fusing Components, Continued

Voltage Ref. Sch. Part Part No. Sym. Description Number 1 M10, 20 Contactor- Supply (M10) OR Return (M20) Fan 193591702 1 1 Contactor- Supply (M10) OR Return (M20) Fan 193591601 1 Contactor- Supply (M10) OR Return (M20) Fan 193598102 1 2 Front Mtd. Aux. Contact- 1NO AND 1NC 193546201 1 1 1 1 3 MMP10, 20 MMP- Supply (MMP10) OR Return (MMP20) Fan 193543404 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 193543403 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 193543304 1 1 3B Link 193547501 1 1 Link 193546001 Link 193547401 1 1 3E Phase Barrier 193547301 1 1 N/S CB10, 20 Circuit Breaker- Supply OR Return Fan 90A 193550209 1 Circuit Breaker- Supply OR Return Fan 80A 193550208 1 Circuit Breaker- Supply OR Return Fan 40A 193550204 1 FB10, 20 Fuseblock- Supply OR Return Fan 193428502 1 Fuse - Supply OR Return Fan 50A 113085252 3 Fuse Cover 193428602 1

208V

230V

460V

575V

N/S= Not Shown on Diagram.

20 HP Motor- Code 22 OR 32= N*Y Voltage Ref. Sch. Part Part No. Sym. Description Number 1 M10, 20 Contactor- Supply (M10) OR Return (M20) Fan 193591701 1 1 Contactor- Supply (M10) OR Return (M20) Fan 193537305 1 Contactor- Supply (M10) OR Return (M20) Fan 193598101 1 2 Front Mtd. Aux. Contact- 1NO AND 1NC 193546201 1 1 1 Front Mtd. Aux. Contact- 1NO AND 1NC 193543801 1 3 MMP10, 20 MMP- Supply (MMP10) OR Return (MMP20) Fan 193543403 1 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 193543013 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 193543303 1 3A Spacer 193545801 1 3B Link 193547501 1 1 Link 193546001 1 Link 193547401 1 3E Phase Barrier 193547301 1 1 Phase Barrier 193545501 1 N/S AFD10, 20 VFD- Supply OR Return Fan 1 1 1 1 1 N/S CB10, 20 Circuit Breaker- Supply OR Return Fan 70A 193550207 1 Circuit Breaker- Supply OR Return Fan 60A 193550206 1 Circuit Breaker- Supply OR Return Fan 30A 193550203 1 FB10, 20 Fuseblock- Supply OR Return Fan 193428502 1 Fuse- Supply OR Return Fan 40A 113085250 3 Fuse Cover- Supply OR Return Fan 193428602 1

208V

230V

460V

575V

N/S= Not Shown on Diagram. 1 Refer to the Inverter Section for VFD p/ns. Reference Code 15 for Inverter brand supplied.

Page 210: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 210

Section N- Main Control BoxPower Panel: (04/2013 & Later)

Supply and Return Fan Contactors, Circuit Breakers, & Fusing Components, Continued

Voltage Ref. Sch. Part Part No. Sym. Description Number 1 M10, 20 Contactor- Supply (M10) OR Return (M20) Fan 193591703 1 Contactor- Supply (M10) OR Return (M20) Fan 193591702 1 Contactor- Supply (M10) OR Return (M20) Fan 193591601 1 Contactor- Supply (M10) OR Return (M20) Fan 193598102 1 2 Front Mtd. Aux. Contact- 1NO AND 1NC 193546201 1 1 1 1 3 MMP10, 20 MMP- Supply (MMP10) OR Return (MMP20) Fan 193543405 1 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 193543305 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 193543304 1 3B Link 193547501 1 1 Link 193546001 Link 193547401 1 1 3E Phase Barrier 193547301 1 1 N/S CB10, 20 Circuit Breaker- Supply OR Return Fan 125A 193550301 1 Circuit Breaker- Supply OR Return Fan 90A 193550209 1 Circuit Breaker- Supply OR Return Fan 40A 193550204 1 FB10, 20 Fuseblock- Supply OR Return Fan 193428502 1 Fuse - Supply OR Return Fan 60A 113085253 3 Fuse Cover 193428602 1

30 HP Motor- Code 22 OR 32= Q*Y

208V

230V

460V

575V

40 HP Motor- Code 32= R*Y Voltage Ref. Sch. Part Part No. Sym. Description Number 1 M10 Contactor- Supply Fan 115A 193591801 1 1 Contactor- Supply Fan 65A 193591701 1 Contactor- Supply Fan 50A 193591602 1 2 Front Mtd. Aux. Contact- 1NO AND 1NC 193546201 1 1 3 MMP10 Circuit Breaker- Supply Fan 150A 193550302 1 1 MMP- Supply Fan 36- 50A 193543402 1 MMP- Supply Fan 28- 40A 193543305 1 3B Link 193547501 1 Link 193547401 1 3C Lugs- MMP10 (kit of 3pc.) 193556201 1 3E Phase Barrier 193547301 1 1 4 OL10 Overload- Supply Fan 50- 200A 193549702 1 4A Terminal Block- Supply Fan 193542601 2 2 N/S CB10 Circuit Breaker- Supply Fan 150A 193550302 1 Circuit Breaker- Supply Fan 125A 193550301 1 Circuit Breaker- Supply Fan 60A 193550206 1 Circuit Breaker- Supply Fan 50A 193550205 1 N/S Lugs- CB10 (kit of 3pc.) 193553301 1 1 N/S= Not Shown on Diagram.

N/S= Not Shown on Diagram.

Page 211: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 211

Section N- Main Control BoxPower Panel: (04/2013 & Later)

Supply and Return Fan Contactors, Circuit Breakers, & Fusing Components, Continued

50 HP Motor- Code 32= S*Y Voltage Ref. Sch. Part Part No. Sym. Description Number 1 M10 Contactor- Supply Fan 150A 193591802 1 1 Contactor- Supply Fan 65A 193591701 1 1 2 Front Mtd. Aux. Contact- 1NO AND 1NC 193546201 1 1 3 MMP10 Circuit Breaker- Supply Fan 150A 193550302 1 1 MMP- Supply Fan 45- 63A 193543403 1 MMP- Supply Fan 36- 50A 193543402 1 3B Link 193547501 1 1 3E Phase Barrier 193547301 1 1 4 OL10 Overload- Supply Fan 50- 200A 193549702 1 1 4A Terminal Block- Supply Fan 193542601 2 2 N/S CB10 Circuit Breaker- Supply Fan 80A 193550208 1 Circuit Breaker- Supply Fan 60A 193550206 1 FB10 Fuseblock- Supply Fan 113085301 1 1 Fuse - Supply Fan 225A 113085205 3 Fuse - Supply Fan 175A 193559501 3

208V

230V

460V

575V

N/S= Not Shown on Diagram.

Page 212: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 212

045

Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts 1 M1- 4 Contactor- Compressor 40A 193591601 4 4 Contactor- Compressor 32A 193537305 4 Contactor- Compressor 25A 193598101 4

1A Front Mtd. Aux. Contact- 2NO AND 2NC 193542701 4 4 4

Compressor MMP’s & Parts 2 Front Mtd. Aux. Contact- 1NO AND 1NC 193546201 4 4 4 Front Mtd. Aux. Contact- 1NO AND 1NC 193543801 4

3 MMP1- 4 Motor Protector- Compressor 36- 45A 193543306 4 Motor Protector- Compressor 28- 40A 193543305 4 Motor Protector- Compressor 14- 20A 193543010 4 Motor Protector- Compressor 11- 16A 193543301 4

3B Link 193547401 4 4 4 Link 193546001 4

N/S Busbar 193546601 2 2 2 Busbar 193544301 2

N/S Busbar Feeder Terminal 193547201 2 2 2 Busbar Feeder Terminal 193545101 2

208v

230V

460V

575V

MMP1- 4 & M1- 4 Contactor Link Detail208/230/575V

MMP1- 4 & M1- 4 Contactor Link Detail460V

Control BoxPower Panel: (04/2013 & Later)

Compressor MMP1 thru 4 and Contactor M1 thru 4Unit Size 045D

MMP

2

Contactor1

3

MMP 3

Contactor

1

Spacer3A

Front Mtd.Aux. Contact

Link 3B

2Front Mtd.

Aux. Contact Link3B

Front Mtd.Aux. Contact 1A

N/S= Not Shown on Diagram.

Page 213: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 213

0 50, 051

Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts 1 M1- 4 Contactor- Compressor 65A 193591701 4 4 Contactor- Compressor 32A 193537305 4 Contactor- Compressor 25A 193598101 4 1A Front Mtd. Aux. Contact- 2NO AND 2NC 193542701 4 4 4

Compressor MMP’s & Parts 2 Front Mtd. Aux. Contact- 1NO AND 1NC 193546201 4 4 4 Front Mtd. Aux. Contact- 1NO AND 1NC 193543801 4 3 MMP1- 4 Motor Protector- Compressor 45- 63A 193543403 4 4 Motor Protector- Compressor 17- 22A 193543011 4 Motor Protector- Compressor 14- 20A 193543302 4 3B Link 193547501 4 4 Link 193546001 4 Link 193547401 4 N/S Busbar, 2 position 193544301 2 Busbar, 2 position 193546601 2 N/S Busbar Feeder Terminal 193545101 2 Busbar Feeder Terminal 193547201 2

208V

230V

460V

575V

Control BoxPower Panel: (04/2013 & Later)

Compressor MMP1 thru 4 and Contactor M1 thru 4Unit Size 050, 051D

MMP

3

Front Mtd.Aux. Contact 2

Contactor

Link 3B

MMP1- 4 & M1- 4 Contactor Link Detail208/230V

MMP

2

Contactor1

3

MMP3

Contactor1

Spacer3A

Front Mtd.Aux. Contact

Link 3B

2Front Mtd.

Aux. Contact Link3B

MMP1- 4 & M1- 4 Contactor Link Detail460V

MMP1- 4 & M1- 4 Contactor Link Detail575V

1A Front Mtd. Aux. Contact

Front Mtd.Aux. Contact 1A

1

N/S= Not Shown on Diagram.

Page 214: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 214

060- 063

Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts 1 M1- 4 Contactor- Compressor 65A 193591701 4 4 Contactor- Compressor 40A 193591601 4 Contactor- Compressor 25A 193598101 4

1A Front Mtd. Aux. Contact- 2NO AND 2NC 193542701 4 4 4 4

Compressor MMP’s & Parts 2 Front Mtd. Aux. Contact- 1NO AND 1NC 193546201 4 4 4 4

3 MMP1- 4 Motor Protector- Compressor 45- 63A 193543403 4 4 Motor Protector- Compressor 22- 32A 193543304 4 Motor Protector- Compressor 18- 25A 193543303 4

3B Link 193547501 4 4 Link 193547401 4 4

N/S Busbar, 2 position 193546601 2 2

N/S Busbar Feeder Terminal 193547201 2 2

Control BoxPower Panel: (04/2013 & Later)

Compressor MMP1 thru 4 and Contactor M1 thru 4Unit Size 060- 063D

MMP1- 4 & M1- 4 Contactor Link Detail208/230V

MMP1- 4 & M1- 4 Contactor Link Detail460/575V

MMP 3

Contactor1

Front Mtd.Aux. Contact

Link3B

MMP

3

2

Contactor

1

Link 3B

1A

208V

230V

460V

575V

1A

Front Mtd.Aux. Contact

2

N/S= Not Shown on Diagram.

Page 215: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 215

Control BoxPower Panel: (04/2013 & Later)

Compressor MMP1 thru 4 and Contactor M1 thru 4Unit Size 068D

3

1

Front Mtd.Aux. Contact

3B

3

2

1

Link 3B

1AFront Mtd.

Aux. Contact

1A

2

068

Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts 1 M1- 4 Contactor- Compressor 65A 193591701 4 4 Contactor- Compressor 40A 193591601 4 Contactor- Compressor 32A 193598102 4

1A Front Mtd. Aux. Contact- 2NO AND 2NC 193542701 4 4 4 4

Compressor MMP’s & Parts 2 Front Mtd. Aux. Contact- 1NO AND 1NC 193546201 4 4 4 4

3 MMP1- 4 Motor Protector- Compressor 57- 75A 193543404 4 Motor Protector- Compressor 45- 63A 193543403 4 Motor Protector- Compressor 22- 32A 193543304 4 4

3B Link 193547501 4 4 Link 193547401 4 4

N/S Busbar, 2 position 193546601 2 2

N/S Busbar Feeder Terminal 193547201 2 2

208V

230V

460V

575V

N/S= Not Shown on Diagram.

Page 216: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 216

Control BoxPower Panel: (04/2013 & Later)

Compressor MMP1 thru 6 and Contactor M1 thru 6Unit Size 070- 071D

MMP1- 6 & M1- 6 Contactor Link Detail208/230/575V

MMP1- 6 & M1- 6 Contactor Link Detail460V

MMP

2

Contactor1

3

3

Contactor1

Spacer3A

Front Mtd.Aux. Contact

Link 3B

2

Front Mtd.Aux. Contact

Link3B1A

070- 071

Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts 1 M1- 6 Contactor- Compressor 40A 193591601 6 6 Contactor- Compressor 32A 193537305 6 Contactor- Compressor 25A 193598101 6

1A Front Mtd. Aux. Contact- 2NO AND 2NC 193542701 6 6 6

Compressor MMP’s & Parts 2 Front Mtd. Aux. Contact- 1NO AND 1NC 193546201 6 6 6 Front Mtd. Aux. Contact- 1NO AND 1NC 193543801 6

3 MMP1- 6 Motor Protector- Compressor 36- 45A 193543306 6 Motor Protector- Compressor 28- 40A 193543305 6 Motor Protector- Compressor 14- 20A 193543010 6 Motor Protector- Compressor 11- 16A 193543301 6

3B Link 193547401 6 6 6 Link 193546001 6

N/S Busbar, 3 position 193546701 2 2 2 Busbar, 3 position 193544401 2

N/S Busbar Feeder Terminal 193547201 2 2 2 Busbar Feeder Terminal 193545101 2

208V

230V

460V

575V

N/S= Not Shown on Diagram.

Front Mtd.Aux. Contact

Page 217: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 217

Control BoxPower Panel: (04/2013 & Later)

Compressor MMP1 thru 6 and Contactor M1 thru 6Unit Size 075D

075

Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts 1 M1- 6 Contactor- Compressor 65A 193591701 6 6 Contactor- Compressor 32A 193537305 6 Contactor- Compressor 25A 193598101 6 1A Front Mtd. Aux. Contact- 2NO AND 2NC 193542701 6 6 6

Compressor MMP’s & Parts 2 Front Mtd. Aux. Contact- 1NO AND 1NC 193546201 6 6 6 Front Mtd. Aux. Contact- 1NO AND 1NC 193543801 6 3 MMP1- 6 Motor Protector- Compressor 45- 63A 193543403 6 6 Motor Protector- Compressor 17- 22A 193543011 6 Motor Protector- Compressor 14- 20A 193543302 6 3B Link 193547501 6 6 Link 193546001 6 Link 193547401 6 N/S Busbar, 3 position 193544401 2 Busbar, 3 position 193546701 2 N/S Busbar Feeder Terminal 193545101 2 Busbar Feeder Terminal 193547201 2

208V

230V

460V

575V

MMP

3

Front Mtd.Aux. Contact 2

Link 3B

MMP1- 6 & M1- 6 Contactor Link Detail208/230V

MMP

2

Contactor1

3

3

Contactor1

3ALink 3B

2Front Mtd.

Aux. Contact Link3B

MMP1- 6 & M1- 6 Contactor Link Detail575V

1A Front Mtd. Aux. Contact

Front Mtd.Aux. Contact 1A

1

Page 218: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 218

Control BoxPower Panel: (04/2013 & Later)

Compressor MMP1 thru 6 and Contactor M1 thru 6Unit Size 079D, Circuit # 1

079

Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts 1 M1, 3, 5 Contactor- Compressor, Cir. # 1 65A 193591701 3 3 Contactor- Compressor, Cir. # 1 32A 193537305 3 Contactor- Compressor, Cir. # 1 25A 193598101 3

1A Front Mtd. Aux. Contact- 2NO AND 2NC, Cir # 1 193542701 3 3 3

Compressor MMP’s & Parts 2 Front Mtd. Aux. Contact- 1NO AND 1NC, Cir. # 1 193546201 3 3 3 Front Mtd. Aux. Contact- 1NO AND 1NC, Cir. # 1 193543801 3

3 MMP1, 3, 5 Motor Protector- Compressor, Cir. # 1 45- 63A 193543403 3 3 Motor Protector- Compressor, Cir. # 1 17- 22A 193543011 3 Motor Protector- Compressor, Cir. # 1 14- 20A 193543302 3

3B Link, Cir. # 1 193547501 3 3 Link, Cir. # 1 193546001 3 Link, Cir. # 1 193547401 3

N/S Busbar, 3 position, Cir. # 1 193544401 1 Busbar, 3 position, Cir. # 1 193546701 1

N/S Busbar Feeder Terminal, Cir. # 1 193545101 1 Busbar Feeder Terminal, Cir. # 1 193547201 1

208V

230V

460V

575V

MMP

3

Front Mtd.Aux. Contact 2

Link 3B

MMP1, 3, 5 & M1, 3, 5 Contactor Link Detail208/230V- Cir. #1

MMP

2

Contactor1

3

MMP3

Contactor1

Spacer3A

Front Mtd.Aux. Contact

Link 3B

2Front Mtd.

Aux. Contact Link3B

MMP1, 3, 5 & M1, 3, 5 Contactor Link Detail460V- Cir. #1

MMP1, 3, 5 & M1, 3, 5 Contactor Link Detail575V- Cir. #1

1AFront Mtd. Aux. Contact

Front Mtd.Aux. Contact 1A

1

N/S= Not Shown on Diagram.

Page 219: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 219

Control BoxPower Panel: (04/2013 & Later)

Compressor MMP1 thru 6 and Contactor M1 thru 6Unit Size 079D, Circuit # 2

208V

230V

460V

575V

N/S= Not Shown on Diagram.

MMP2, 4, 6 & M2, 4, 6 Contactor Link Detail208/230V- Cir. #2

MMP2, 4, 6 & M2, 4, 6 Contactor Link Detail460/575V- Cir. #2

MMP 3

Contactor

1

Front Mtd.Aux. Contact

Link3B

MMP

3

2

Contactor

1

Link 3B

Front Mtd.Aux. Contact

1AFront Mtd.

Aux. Contact

1A

Front Mtd.Aux. Contact

2

079

Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts 1 M2, 4, 6 Contactor- Compressor, Cir # 2 65A 193591701 3 3 Contactor- Compressor, Cir # 2 40A 193591601 3 Contactor- Compressor, Cir # 2 25A 193598101 3

1A Front Mtd. Aux. Contact- 2NO AND 2NC, Cir # 2 193542701 3 3 3 3

Compressor MMP’s & Parts 2 Front Mtd. Aux. Contact- 1NO AND 1NC, Cir # 2 193546201 3 3 3 3

3 MMP2, 4, 6 Motor Protector- Compressor, Cir # 2 45- 63A 193543403 3 3 Motor Protector- Compressor, Cir # 2 22- 32A 193543304 3 Motor Protector- Compressor, Cir # 2 18- 25A 193543303 3

3B Link, Cir # 2 193547501 3 3 Link, Cir # 2 193547401 3 3

N/S Busbar, 3 position, Cir # 2 193546701 1 1

N/S Busbar Feeder Terminal, Cir # 2 193547201 1 1

Page 220: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 220

208V

230V

460V

575V

208V

230V

460V

575V

208V

230V

460V

575V

045- 060 061- 071 075- 079 Ref. Sch. Part Part No. Symbol Description Number Cond. Fan Contactors 7 M11- 14 M21- 24 Contactor- Cond. Fan 193534105 4 4 4 4 6 6 6 6 8 8 8 8 Fan MMP’s & Parts 7B Link- MMP 193545901 4 4 4 4 6 6 6 6 8 8 8 8 8 MMP11 Motor Protector 193542911 1 1 1 Motor Protector 193542910 1 1 1 Motor Protector 193542908 1 1 1 Motor Protector 193542907 1 1 1 MMP12 Motor Protector 193542911 1 1 1 Motor Protector 193542910 1 1 1 Motor Protector 193542908 1 1 1 Motor Protector 193542907 1 1 1 MMP13 Motor Protector 193542911 1 1 Motor Protector 193542910 1 1 Motor Protector 193542908 1 1 Motor Protector 193542907 1 1 MMP14 Motor Protector 193542911 1 Motor Protector 193542910 1 Motor Protector 193542908 1 Motor Protector 193542907 1 MMP21 Motor Protector 193542911 1 1 1 Motor Protector 193542910 1 1 1 Motor Protector 193542908 1 1 1 Motor Protector 193542907 1 1 1 MMP22 Motor Protector 193542911 1 1 1 Motor Protector 193542910 1 1 1 Motor Protector 193542908 1 1 1 Motor Protector 193542907 1 1 1 MMP23 Motor Protector 193542911 1 1 Motor Protector 193542910 1 1 Motor Protector 193542908 1 1 Motor Protector 193542907 1 1 MMP24 Motor Protector 193542911 1 Motor Protector 193542910 1 Motor Protector 193542908 1 Motor Protector 193542907 1 N/S Bus Bar, 2 Position 193544301 2 2 2 2 Bus Bar, 3 Position 193544401 2 2 2 2 Bus Bar, 4 Position 193544501 2 2 2 2 N/S Bus Bar Top Feed 193545101 2 2 2 2 2 2 2 2 2 2 2 2

Control BoxPower Panel: (04/2013 & Later)

Condenser Fan Contactors, MMPs, & FusingFanTrol Units (Code 47= 1, 3)

MMP

8

Link 7B

Contactor7

N/S= Not Shown on Diagram.

Page 221: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 221

Control BoxPower Panel: (04/2013 & Later)

Condenser Fan Contactors, MMPs, & FusingSpeedTrol Units (Code 47= 2, 4)

045- 060 061- 071 075- 079 Ref. Sch. Part Part No. Symbol Description Number Cond. Fan Contactors 7 M12 - 14 M22 - 24 Contactor- Cond. Fan 193534105 2 2 2 2 4 4 4 4 6 6 6 6 Fan MMP’s & Parts 8 MMP12 Motor Protector 193542911 1 1 1 Motor Protector 193542910 1 1 1 Motor Protector 193542908 1 1 1 Motor Protector 193542907 1 1 1 MMP13 Motor Protector 193542911 1 1 Motor Protector 193542910 1 1 Motor Protector 193542908 1 1 Motor Protector 193542907 1 1 MMP14 Motor Protector 193542911 1 Motor Protector 193542910 1 Motor Protector 193542908 1 Motor Protector 193542907 1 MMP22 Motor Protector 193542911 1 1 1 Motor Protector 193542910 1 1 1 Motor Protector 193542908 1 1 1 Motor Protector 193542907 1 1 1 MMP23 Motor Protector 193542911 1 1 Motor Protector 193542910 1 1 Motor Protector 193542908 1 1 Motor Protector 193542907 1 1 MMP24 Motor Protector 193542911 1 Motor Protector 193542910 1 Motor Protector 193542908 1 Motor Protector 193542907 1 8E Phase Barrier 193545501 2 2 2 2 N/S Bus Bar, 2 Position 193544301 2 2 2 2 Bus Bar, 3 Position 193544401 2 2 2 2 N/S Bus Bar Top Feed 193545101 2 2 2 2 2 2 2 2 SpeedTrol Fusing 9 F11, 21 Fuse Block 023780232 2 2 2 2 2 2 2 2 2 2 2 2 9B Fuse Cover/Puller 349938227 6 6 6 6 6 6 6 6 6 6 6 6 9A F11, 21 Fuse- SpeedTrol 349937127 6 6 6 6 6 6 Fuse- SpeedTrol 049759820 6 6 6 Fuse- SpeedTrol 049759809 6 6 6

208V

230V

460V

575V

208V

230V

460V

575V

208V

230V

46V

575V

MMP & Contactor Detail SpeedTrol Fusing Detail

7

MMP8

Link 7B

Contactor

Fuse Block

Puller

Fuse

9B

9A

9

N/S= Not Shown on Diagram.

8EPhase Barrier

Page 222: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 222

Unit Voltage

Ref. Sch. Part Part No. Sym. Description Number ERW Contactor & Parts 1

7 M60 Contactor 7A 193534105 1 1 1

7B Link 193545901 1 1 1

Heat Wheel MMP’s & Parts 1

8 MMP60 Motor Protector 3.5- 5A 193542910 1 Motor Protector 1.8- 2.5A 193542907 1 Motor Protector 2.2- 3.2A 193542908 1 8E Phase Barrier 193545501 1 1 1

ERW Fusing 2

9 FB60 Fuseblock 023780232 1 1 9A F60 Fuse 7A 349937127 3 Fuse 3A 049759809 3 9B Fuse Cover/Puller 349938227 3 3

N/S CB60 Circuit Breaker 15A 193550201 3

208/

230V

460V

575V

Section N- Main Control BoxPower Panel: (04/2013 & Later)

Heat/Energy Recovery Wheel Contactors, MMPs & Fusing

N/S= Not shown on diagram.1 Units With No Frost Protection Inverter (Code 24= Y, 1, 2).2 Units w/ Frost Protection Inverter (Code 24= F).

7

MMP

8

Link 7B

Contactor

8EPhase Barrier

MMP & Contactor Detail ERW Fusing Detail

Fuse Block

Fuse9A

9

Cover

9B

Page 223: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 223

Section N- Main Control BoxIntelligent Equipment: Code 23= ****A (Mid 2012 & Later)

Intelligent Equipment™ (IE) from Daikin Applied is a secure, cloud-based solution that enables delivery of information to end users and/or service technicians via the web or mobile device. Intelligent Equipment measures the power and performance of every unit providing real-time data streams for benchmarking performance and monitoring system operation.

A power measurement module and communications gateway installed on Daikin Applied equipment enables the unit to be directly connected to the internet via a wireless connection (Wi-Fi, cellular) or through a local area network (LAN) providing management, monitoring, control, analysis, and decision-making functionality.

Note that this feature may be added to the unit in the field after the initial purchase. In this case, the coding shown above does NOT apply.

Click on this link to access the RPL for Intelligent Equipment: 7000506.

Page 224: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 224

Section O- Refrigeration TubingNotes

Primary Codes that pertain: 03, 45, 46, 48, 54 (Mid 2012 & Later)

Code 03, cooling coil face area, affects the Liquid Line Solenoid and main Expansion Valve selection.

Code 45, Compressor mounting, pertains to the Suction and Discharge Tubing located in the Condenser Section. The suction and discharge lines only pertain to RPS and RCS units. RFS units do not have an integrated Condenser Section and are designed to hook up to a separate condensing unit.

Code 46, Hot Gas Bypass, pertains to the Liquid Line tubing on RPS and RFS units. The drawing below shows the Hot Gas Bypass option installed (Code 46= 1, 2, 4). RCS units come from the factory with NO Liquid Line components installed (Solenoid Valve, Filter Drier, Sight Glass). HGBP can be field installed, however it is important to note that any additional piping required for field installed HGBP is ALWAYS field supplied. Code 48 determines if the unit is equipped with Hot Gas Reheat AND/OR IBC Seismic Construction. The Hot Gas Reheat option (Code 48= H, K) adds a Microchannel Coil, Step Valve, Control Board, Sensor and additional piping. Note that the Hot Gas Reheat option is not shown in the Refrigeration Tubing diagram below.

Code 54 (Mid 2012 & Later) determines if the unit is equipped with Hot Gas Reheat or Modulating Liquid Subcooling Reheat. These options are not shown in the Refrigeration Tubing diagram below.

Distributor

Expansion

Valve

Sight Glas

s

Liquid Line Solen

oid ManualShutoffValve

FilterDrier

Suct

ion

Line

Evaporator Coil

Compressor

Discharge Line

Hot Gas Bypass

Solenoid

CondenserCoil

Section O- Refrigeration TubingDiagram

Schematic (Circuit # 1 OR Circuit #2):

Page 225: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 225

Part Part Unit Size 1

Description Number 045 050 051 060 061 062 063 Suction Line Stem- Schrader Valve 034915300 2 2 2 2 2 2 2 Core- Schrader Valve 026541100 2 2 2 2 2 2 2 Cap- Schrader Valve 032943500 1 1 1 1 1 1 1

Discharge Line Valve- Shut Off 113114501 1 1 1 1 1 1 1 Liquid Line Sight Glass Assy 015997805 1 1 1 1 1 1 1 Shell- Replaceable Filter Drier 3 001360700 1 1 1 1 1 1 1 Core, Replaceable- Filter Drier 3 001360800 1 1 1 1 1 1 2 Filter Drier- Sealed Core 098803001 1 1 1 1 1 1 1 Valve- Solenoid 113142901 1 1 1 1 1 1 1 Valve- Shutoff 049266501 1 1 1 1 1 1 1 Check Valve, .875” 112053305 1 1 1 1 1 1 1

Liquid Line Kit (RCS to RFS) 193330712 5 5 N/A 5 5 5 5

Liquid Line Kit (RCS Standalone) 193330711 5 5 N/A 5 N/A 5 5

Expansion Valve- Small Face Area Coils (C03= S) 3 & 5 Row Coils 258946901 1 1 1 4 Row Coils 403589405 1 1 1 3 & 5 Row Coils 403589407 1 1 1 1 4 Row Coils 403589409 1 1 1 1

Expansion Valve- Large Face Area Coils (C03= L) All Coils 403589606 N/A 2 2 2 2 All Coils 403589401 2 2

Hot Gas Bypass Hot Gas Bypass Kit 193330721 2 2 2 2 2 2 2

Valve only, Hot Gas Bypass 258951301 4 4 4 4 4 4 4

Section O- Refrigeration TubingValves, Filter Driers, Sight Glasses, & Hot Gas Bypass/Liquid Line Kits

1 Quantity is PER circuit. Each unit has two (2) circuits. The components listed are the same for either circuit.2 Each Hot Gas Bypass Kit covers ONE circuit. To add Hot Gas Bypass to BOTH circuits order TWO kits. The Hot Gas Bypass Kit

includes a Solenoid Valve and Instructions. Due to the many possible variations in unit location configurations ANY AND ALL additional piping and wiring required is field supplied.

3 Code 46= 3, 4, 5.4 Code 46= 1, 2, 4, 5. If Code 46= 1, 4 then there is Hot Gas Bypass on Circuit #1 only. 5 Each Liquid Line Kit covers ONE circuit. To add Liquid Line components to BOTH circuits order TWO kits. The RCS Standalone

Kit includes a Solenoid Valve, Replaceable Core Filter Drier, Sight Glass, and Instructions. The RCS to RFS Kit contains all the previously mentioned parts except for the Solenoid Valve. In either case, Any and ALL piping and additional wiring required is field supplied.

Page 226: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 226

Section O- Refrigeration Tubing Valves, Filter Driers, Sight Glasses, & HGBP/Liquid Line Kits, Continued

Part Part Unit Size 1

Description Number 068 070 071 075 079 Suction Line Stem- Schrader Valve 034915300 2 2 2 2 2 Core- Schrader Valve 026541100 2 2 2 2 2 Cap- Schrader Valve 032943500 1 1 1 1 1

Discharge Line Valve- Shut Off 113114501 1 Valve- Shut Off 113114601 1 1 1 1 Liquid Line Sight Glass Assy 015997805 1 1 1 1 Sight Glass Assy 015997806 1 Shell- Replaceable Filter Drier 3 001360700 1 1 1 1 Shell- Replaceable Filter Drier 3 019190500 1 Core, Replaceable- Filter Drier 3 001360800 1 1 1 1 2 Filter Drier- Sealed Core 098803001 1 1 1 1 Filter Drier- Sealed Core 021057426 1 Valve- Solenoid- Small Face Area Coils (C03= S) 113142901 1 1 1 1 Valve- Solenoid- Small Face Area Coils (C03= S) 113143001 1 Valve- Solenoid- Large Face Area Coils (C03= L) 113142901 1 1 1 1 Valve- Solenoid- Large Face Area Coils (C03= L) 113142801 1 Valve- Shutoff 049266501 1 1 1 1 Valve- Shutoff 049266502 1 Check Valve, .875” 112053305 1 1 1 1 Check Valve, 1.125” 112053304 1

Liquid Line Kit (RCS to RFS) 193330712 5 5 5 5 5

Liquid Line Kit (RCS Standalone) 193330711 5 5 N/A 5 N/A

Expansion Valve- Small Face Area Coils (C03= S) 3 & 5 Row Coils 403589407 1 1 1 4 Row Coils 403589409 1 1 1 3 & 5 Row Coils 403589501 1 4 Row Coils 403589503 1 3 & 5 Row Coils 403589502 1 4 Row Coils 403589504 1

Expansion Valve- Large Face Area Coils (C03= L) All Coils 403589401 2 2 2 2 All Coils 258946901 2

Hot Gas Bypass Hot Gas Bypass Kit 193330721 2 2 2 2 2

Valve only, Hot Gas Bypass 258951301 4 4 4 4 4

1 Quantity is PER circuit. Each unit has two (2) circuits. The components listed are the same for either circuit.2 Each Hot Gas Bypass Kit covers ONE circuit. To add Hot Gas Bypass to BOTH circuits order TWO kits. The Hot Gas

Bypass Kit includes a Solenoid Valve and Instructions. Due to the many possible variations in unit location configurations ANY AND ALL additional piping and wiring required is field supplied.

3 Code 46= 3, 4, 5.4 Code 46= 1, 2, 4, 5. If Code 46= 1, 4 then there is Hot Gas Bypass on Circuit #1 only. 5 Each Liquid Line Kit covers ONE circuit. To add Liquid Line components to BOTH circuits order TWO kits. The RCS

Standalone Kit includes a Solenoid Valve, Replaceable Core Filter Drier, Sight Glass, and Instructions. The RCS to RFS Kit contains all the previously mentioned parts except for the Solenoid Valve. In either case, Any and ALL piping and ad-ditional wiring required is field supplied.

Page 227: RPL: RPS/RFS/RDT/RCS 045-079 Tons Vintage D, …salesportal.daikinapplied.com/bizlit/DocumentStorage/Rooftop... · Vintage D Unit Model Code 44= R, D ... Key, & Lock (All Sections)

Rooftop Std. Cmpr. Units: RPS,RDT,RFS,RCS 045-079 “D” Rev. AQ 02/18 RPL 7000137 / Page 227

Section O- Refrigeration Tubing Hot Gas Reheat 1

(Code 48= H, K OR (Code 54= BM, BL)

200

213

213

212

212

200

Ref. Part Part Unit Size No. Description Number 045 050 051 060 062 063 068 070 071 075 079 200 Microchannel Coil Module 113152801 2 2 2 2 2 2 2 2 2 2 2 Microchannel Coil Module, E-Coated 404047402 2 2 2 2 2 2 2 2 2 2 2 N/S Electronic Step Valve 113167705 1 1 1 1 1 1 1 N/S Electronic Step Valve 113167706 2 2 2 2 N/S Valve- Motor Kit 113167708 1 1 1 1 1 1 1 2 2 2 2 N/S Valve- Washer (order with Motor kit) 300045244 1 1 1 1 1 1 1 2 2 2 2 N/S Sensor 113167904 1 1 1 1 1 1 1 1 1 1 1 211 Coil divider 910100428 1 1 1 1 1 1 1 1 1 1 1 212 Support channel- (Connection side) 113172601 2 2 2 2 2 2 2 2 2 2 2 213 Support channel- (Return side) 113172701 2 2 2 2 2 2 2 2 2 2 2 233 Check Valve, .875” 112053305 1 1 1 1 1 1 1 1 1 1 Check Valve, 1.125” 112053304 1 234 Valve- Bleed Down 404031001 1 1 1 1 1 1 1 1 1 1 1 235 Coil- Bleed Down Valve 404031101 1 1 1 1 1 1 1 1 1 1 1

AirFl

ow

233235

234

N/S= Not Shown on Diagram.1 Hot Gas Reheat is located on Circuit #2 only.