RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor...

216
Replacement Parts List No. 700015000 Revision AQ 08/2019 Daikin McQuay Roofpak™ Applied Rooftop Units Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.DaikinApplied.com

Transcript of RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor...

Page 1: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Replacement Parts List No. 700015000Revision AQ 08/2019

DaikinMcQuay

Roofpak™Applied Rooftop Units

Standard & Digital Scroll Compressor Models

RPS, RFS, RCS015 - 042

Vintage DCode 44= R, D

To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.DaikinApplied.com

Page 2: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 2

ContentsParts List Revision History .............................................................................................................................................. 6Nomenclature Unit Model and Serial Number ...................................................................................................................................... 7 Unit Code Index ..................................................................................................................................................... 8- 14Unit Layout Diagrams ............................................................................................................................................... 15, 16Electrical Legend ..................................................................................................................................................... 17- 20Section A1- Outdoor/Return/Economizer Air Section Notes ........................................................................................................................................................................... 21 100% Outside Air Damper with Hood No Return Air Plenum: Code 20= AE, AY AND Code 19= YY ......................... 22 100% Outside Air Damper with Hood: Code 20= AE, AY AND Code 19= YY ............................................................. 23 0- 30% Outside Air Section Damper: Code 20= BE, BY AND Code 19= BY, HY ........................................................ 24 0- 100% Economizer Section with Barometric Exhaust Damper- Units without Return Air Fans ................................ 25 0- 100% Economizer Section with Exhaust Damper- Units with 15" Forward Curved Return Air Fans ...................... 26 0- 100% Economizer Section with Exhaust Damper- Units with 30" Air Foil Return Air Fans .................................... 27 0- 100% Economizer Section with Exhaust Damper- Units with 40" Air Foil Return Air Fans .................................... 28 0- 100% Economizer Assembly Diagrams .................................................................................................................. 29 0- 100% Economizer Assembly Components ............................................................................................................. 30 California Title 24 Assembly: Code 33 (Mid 2012 & Later) = *F*** ............................................................................... 31 Return Air Plenum Isolation Damper with Actuator ACT6 ..................................................................................... 32, 33 Design Flow ................................................................................................................................................................ 34 Return Air Fan Mounting- 15" Forward Curved Fan .................................................................................................... 35 Return Air Fan Mounting- 30" and 40" Airfoil Fan Rubber in Shear Components, Spring Mount Diagram ................. 36 Return Air Fan Mounting- 30" Spring and Seismic Mount Components: Code 21= 30B2, 30B3 ................................ 37 Return Air Fan Mounting- 40" Spring and Seismic Mount Components: Code 21= 40B2, 40B3 ................................ 38 Return Air Fan Deck- 15" Fans: Code 21= 15F1, 15F2, 15F3 .................................................................................... 39 Return Air Fan Deck- 30" Fans: Code 21= 30B1, 30B2, 30B3 ................................................................................... 40 Return Air Fan Deck- 40" Fans: Code 21= 40B1, 40B2, 40B3 ................................................................................... 41 Return Air Fan Motors & Motor Mounts.................................................................................................................. 42, 43 Section Mounted Controls- OAE, RAE, LT11, S11, REC11 ........................................................................................ 44Section A2- Outdoor/Return Air w/ Heat Recovery Section Notes ........................................................................................................................................................................... 45 100% Outside Air Low Flow: Code 20= 1E ................................................................................................................. 46 100% Outside Air High Flow: Code 20= 2E ................................................................................................................ 47 Economizer: Code 20= 3E .......................................................................................................................................... 48 24" Return Fan Detail- Fan Components .............................................................................................................. 49, 50 24" Return Fan Detail- Fan Mounts ...................................................................................................................... 51, 52 Low Leak Damper Detail- Outdoor/Return ACT3, 4 .................................................................................................... 53 Low Leak Bypass Damper Detail- Economizer ACT12 ............................................................................................... 54 Heat Recovery/Enthalpy Wheel .................................................................................................................................. 55 VFD60 Frost Protection Inverter: Code 24= F ............................................................................................................ 56 Section Mounted Controls- OAE, RAE, RAT, EAT, LAT ............................................................................................. 57 Section Mounted Controls- SD2, HUM1, LT11, S11, REC11 ....................................................................................... 58Section B- DrawThru Filter/Blank/Empty Section Notes ........................................................................................................................................................................... 59 Air Blender .................................................................................................................................................................. 59 Section Mounted Controls- PC5 .................................................................................................................................. 59 Filter Section & Magnehelic Differential Pressure Gauge ........................................................................................... 60Section C- DrawThru Blank/Empty Section or Separate Inverter Section Notes ........................................................................................................................................................................... 61Section D- DrawThru Cooling Section Notes ........................................................................................................................................................................... 62 Evaporator Coil Drain Pans and Gaskets- Unit Sizes 035- 042D ............................................................................... 63 Evaporator Coils- Unit Sizes 035- 042D ..................................................................................................................... 64Section E- DrawThru Blank/Empty Section Notes ........................................................................................................................................................................... 65 Section Mounted Controls- LT17, REC17, S17 ........................................................................................................... 65

Page 3: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 3

Contents, ContinuedSection F- Supply Air Section Notes ........................................................................................................................................................................... 66 DrawThru Evaporator Coil Drain Pans and Gaskets- Unit Sizes 015- 031D .............................................................. 67 Evaporator Coils- Unit Sizes 015- 031D ..................................................................................................................... 68 Fan Assembly 15" X 6" and 15" X 15" Forward Curved Fans- Unit Sizes 015- 031D ................................................. 69 Fan Assembly 20" Airfoil Fans- Unit Sizes 015- 031D ................................................................................................ 70 Fan Assembly 24" Forward Curved LP Fans- Unit Sizes 035- 042D .......................................................................... 71 Fan Assembly- 24" Airfoil Fans- Unit Sizes 035- 042D ............................................................................................... 72 Supply Air Fan Mounting- 15" X 6": Code 31= 06F1, 06F2, 06F3 .............................................................................. 73 Supply Air Fan Mounting- 15" X 15": Code 31= 15F1, 15F2, 15F3 ............................................................................ 74 Supply Air Fan Mounting- 20" Airfoil Fan: Code 31= 20A1, 20A2, 20A3 ..................................................................... 75 Supply Air Fan Mounting- 24" Airfoil Fan: Code 31= 24A1, 24A2, 24A3 ..................................................................... 76 Supply Air Fan Mounting- 24" Forward Curved Fan: Code 31= 24F1, 24F2, 24F3 .................................................... 77 Supply Fan Motors ................................................................................................................................................ 78, 79 Inverter & Inverter Bypass Control Box- Motor HP 1- 5 (03/2013 & Earlier) ......................................................... 80, 81 Inverter & Inverter Bypass Control Box- Motor HP 1- 5 (4/2013 & Later) ............................................................. 82, 83 Inverter & Inverter Bypass Control Box- Motor HP 7.5- 25 (03/2013 & Earlier) .................................................... 84- 86 Inverter & Inverter Bypass Control Box- Motor HP 7.5- 25 (4/2013 & Later) ......................................................... 87- 89 Inverters (VFD/AFDs) ........................................................................................................................................... 90- 93 Section Mounted Controls- PC7, EFT, HL22, LT10, S10, REC10, UV Lights ............................................................. 94Section G- BlowThru Heat Section Notes ........................................................................................................................................................................... 95 Option 1- Blank/Empty Section: Code 04= Y Diffusers .................................................................................................................................................................... 96 Option 2- Hot Water OR Steam Heating Coil: Code 04= W, S Coils and Coil Compartment Components ............................................................................................................... 97 Valves: Code 04= W, S AND Code 34= W****E, S****E .......................................................................................... 98 Option 3- Electric Heat: Code 04= E Diffusers, High Limit HL4, HL14 & HL 31- 50 ........................................................................................................... 99 Electric Heating Assemblies and Elements ............................................................................................................ 100 Electric Heat Control Box- No Controls Diagram ................................................................................................... 101 Electric Heat Control Box- No Controls Components .................................................................................... 102- 104 Electric Heat Control Box- MicroTech III ........................................................................................................ 105- 108 Option 4- Gas Heat: Code 04= A Heat Exchangers & Vestibules- 200, 250 MBH Furnaces ..................................................................................... 109 Heat Exchangers & Vestibules- 320, 400, 500, 640, 650, 790, 800, 1000 MBH Furnaces ................................... 110 Modulating Burner- Burner Box, Pilot Valve, Pressure Regulator Diagram ........................................................... 111 Modulating Burner- Components ................................................................................................................... 112, 113 Hi Turn Down Burner- Diagram .............................................................................................................................. 114 Hi Turn Down Burner- Components ................................................................................................................115- 117 Modulating Burner Controls- No Controls: Code 12= YC, YM- Diagram ................................................................ 118 Modulating Burner Controls- No Controls: Code 12= YC, YM- Components ......................................................... 119 Modulating Burner Controls- MicroTech III: Code 12= *E, *F, *W .......................................................................... 120 Hi Turn Down Burner Controls- No Controls: Code 12= YC, YM- Diagram ........................................................... 121 Hi Turn Down Burner Controls- No Controls: Code 12= YC, YM- Components .................................................... 122 Hi Turn Down Burner Controls- MicroTech III: Code 12= *E, *F, *W ...................................................................... 123 Gas Train Inlet- Modulating Burner: Code 34= ****E*, ****R*, ****S* ..................................................................... 124 Gas Train Inlet- Hi Turn Down Burner: Code 34= ****H*, ****T*, ****U* ................................................................. 125 Gas Train Controls- Modulating Burner: Code 34= ****E*, ****R*, ****S* (GV2, GV3) .......................................... 126 Gas Train Controls- Hi Turn Down Burner: Code 34= ****H*, ****T*, ****U* (GV1, GV2, GV4, GV5, GV6) ........... 127 Gas Train Outlet ..................................................................................................................................................... 128 Gas Train Damper Linkage- Modulating Burners / VM1 Actuator: Code 34= ****E*, ****R*, ****S* ........................ 129 Cabinet Doors, Gasketing, Hardware & Flue Box Mounting: Code 34= 020***, 025*** ......................................... 130 Cabinet Doors, Gasketing, Hardware & Flue Box Mounting: Code 34= 032*** thru 100*** .................................. 131Section H- BlowThru Heat Blank/Empty Section Notes ......................................................................................................................................................................... 132 Access Door Latching Assemblies, Key, & Lock (All Sections) .................................................................................. 132

Page 4: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 4

Contents, ContinuedSection I- BlowThru Cooling Section Notes ......................................................................................................................................................................... 133 BlowThru Evaporator Coil Drain Pans and Gaskets- Unit Sizes 035- 042D ............................................................. 134 Evaporator Coils- Unit Sizes 035- 042D ................................................................................................................... 135Section J- Final Filter Section Notes ......................................................................................................................................................................... 136 Section Mounted Controls- HL23, PC6, SPS6 .......................................................................................................... 136 Filter Frame, Filter Gaskets, Filters ........................................................................................................................... 137Section K- Discharge Plenum Section Notes ......................................................................................................................................................................... 138 Section Mounted Controls- OAT, DAT, SD1 ............................................................................................................... 138 Damper Assembly- w/ Actuator ACT5 ....................................................................................................................... 139Section L- Out-of-Airstream Blank/Empty Section Notes ......................................................................................................................................................................... 140 Section Mounted Controls- LT20, S20, REC20 ......................................................................................................... 140Section M- Condenser Section Notes ................................................................................................................................................................. 141, 142 Fan Deck, Coil Guard Diagrams- Unit Sizes 015- 026D ........................................................................................... 143 Fan Deck, Coil Guard Diagrams- Unit Sizes 030- 042D ........................................................................................... 144 Standard Condenser Fan Components: Code 47= 1, 2, 5, 6 .................................................................................... 145 Quiet Fan Assembly: Code 47= 3, 4 ......................................................................................................................... 146 Standard OR Digital Compressors Circuit #1 .................................................................................................... 147, 148 Standard Scroll Compressors Circuit #2 ........................................................................................................... 149, 150 Standard Scroll Compressor Crankcase Heaters & Compressor Mounting .............................................................. 151 Digital Scroll Compressors Circuit # 2 & Crankcase Heaters .................................................................................... 152 Digital Scroll Compressor Components & T12, T13 Transformers/Fusing- CDT, SV7 .............................................. 153 Condenser Coils, Pressure Controls, Coil & Vandal Guards ............................................................................ 154, 155 Pressure Controls- AFD11, AFD21, LR11, LR21, LP1, LP2, HP1, HP2, PC13, PC23 (RPS units Only) ......... 156, 157 Pressure Controls- Manifold Mounted HP1, HP2, LP1, LP2, SPTRL (RCS Units Only) ........................................... 158 Pressure Controls- Manifold Mounted, Digital Compressor Units- HP1, HP2, LP1, LP2, SPTRL ............................. 159 Condenser Control Box- No Controls, Diagrams (RCS Units Only) .......................................................................... 160 Condenser Control Box- MicroTech III Controls Diagram (RCS Units Only) ............................................................. 161 Condenser Control Box- Components (RCS Units Only) .................................................................................. 162, 163 Control Box- Factory Supplied Line Voltage Option- T6, DS6, FU6A, FU6B, FU6C, TB7, TB8 ................................ 164Section N- Main Control Box Notes ................................................................................................................................................................. 165, 166 Control Box Component Label Diagram .................................................................................................................... 167 Control Panel Units with No Controller: Code 12= YM, YC- Diagram ........................................................................................... 168 Units with No Controller: Code 12= YM, YC- Components ..................................................................................... 169 Control Panel (03/2013 & Earlier) MicroTech III Units with Controller: Code 12= *E, *F, *W- Diagram ....................................................................... 170 MicroTech III Units with Controller: Code 12= *E, *F, *W- Components ........................................................ 171, 172 Control Panel: (04/2013 & Later) MicroTech III Units with Controller: Code 12= *E, *F, *W- Diagram ....................................................................... 173 MicroTech III Units with Controller: Code 12= *E, *F, *W- Components ........................................................ 174, 175 Power Panel (03/2013 & Earlier) Power Panel Diagram ............................................................................................................................................ 176 Terminal Blocks, T1 Transformer, Fuses ................................................................................................................ 177 Fuses, Ground Fault Protection, Phase Protection (PVM1, 2), Power Supply, Power Blocks ............................... 178 Disconnect Switches, Plugs ................................................................................................................................... 179 Circuit Breakers ..................................................................................................................................................... 180 Supply MMP10 & M10 Fan Contactor, Return MMP20 & M20 Fan Contactor Diagrams ...................................... 181 Supply MMP10 & M10 Fan Contactor, Return MMP20 & M20 Fan Contactor Components ......................... 182- 185 Compressor MMP1, MMP2 and Contactor M1, M2- Unit Size 015 ....................................................................... 186 Compressor MMP1, 2, 4 and Contactor M1, 2, 4- Unit Sizes 020- 031 ................................................................. 187 Compressor MMP1 thru 4 and Contactor M1 thru 4- Unit Sizes 035- 042D .......................................................... 188 Condenser Fan Contactors, MMPs, & Fusing ............................................................................................... 189, 190 Energy Recovery Wheel MMP60, 61 & Contactor M60, 61: Code 24= Y .............................................................. 191

Page 5: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 5

Contents, ContinuedSection N- Main Control Box, Continued Power Panel (04/2013 & Later) Power Panel Diagram ............................................................................................................................................ 192 Terminal Blocks, T1 Transformer, Fuses ................................................................................................................ 193 Fuses, Ground Fault Protection, Phase Protection (PVM1, 2), Power Supply, Power Blocks ............................... 194 Disconnect Switches, Plugs ................................................................................................................................... 195 Supply MMP10 & M10 Fan Contactor, Return MMP20 & M20 Fan Contactor Diagrams .......................................196 Supply and Return Fan Contactors, Circuit Breakers, & Fusing Components ......................................................... 197- 202 Compressor Motor Protector MMP1- 4, & Contactor M1- 4 Diagrams ............................................................................................................................................................. 203 Unit Sizes 015, 016D .......................................................................................................................................... 204 Unit Sizes 020- 031D ................................................................................................................................. 205, 206 Unit Sizes 035- 042D ......................................................................................................................................... 207 Condenser Fan Contactors, MMPs, & Fusing ............................................................................................... 208, 209 Energy Recovery Wheel Contactors, MMPs, & Fusing ......................................................................................... 210 Intelligent Equipment ..................................................................................................................................................211Section O- Refrigeration Tubing Notes ........................................................................................................................................................................ 212 Refrigeration Tubing Diagrams ......................................................................................................................... 212, 213 Valves, Filter Driers, Sight Glasses, & Hot Gas Bypass/Liquid Line Kits .......................................................... 214, 215 Modulating Hot Gas Reheat ...................................................................................................................................... 216

Page 6: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 6

Rev. Date Description A- AN Various Archived Revisions A thru AN. AO 04/19 Various: Rewrote Note re. contacting DAA. Changed "HGRH" to "MHGR" (Modulating Hot Gas Reheat). Page 8: Rewrote footnote # 1. Added footnote # 2. Page 13: Updated Code 47. Rewrote footnote # 1. Page 19, 20, 169, 175: Misc. updates/corrections/additions. Page 44, 58, 65, 94, 140: Updated Light/Rec. p/ns. Page 50, 69, 70, 71, 72: Added footnote re. setscrew vs. concentric locking collar bearings. Page 141, 142, 165, 166, 212: Rewrote Notes. Page 145: Added TEAO mtrs. to table. Rewrote/added to footnotes. Rewrote pg. header & updated the TOC. Page 152: Updated digital cmpr. table & rewrote footnotes. Page 157: Rewrote footnotes. Updated coding. Page 161: Rewrote pg. header. Page 163, 195: Corrected DS shaft p/ns for 4/13 & Later units. Rewrote footnotes. Page 165, 166: Rewrote Notes. Page 168, 169: Misc. updates. Rewrote pg. header & updated the TOC. Page 171, 174: Rewrote Remote Keypad description. Added MCB Battery p/n. Page 185: Added missing footnote notation. Page 203: Added side Aux. Bubs. Rewrote Bub. headers. Page 204- 207: Updated Aux. p/ns. Corrected qtys. as needed. Added footnote # 1. Page 209: Deleted footnote. Page 216: Rewrote pg. header & updated the TOC. AP 08/19 Page 142, 166: Rewrote Notes. Page 145: Updated table. Rewrote footnotes. Page 164: Updated dwgs. & table. Rewrote footnotes & pg. header. Updated the TOC. AQ 08/19 Page 97: Updated HW coil p/ns. Rewrote footnote # 1. Rewrote pg. header.

Parts List Revision History

Daikin Applied, 13600 Industrial Park Blvd., P.O. Box 1551, Minneapolis, MN 55440 (763) 553-5330

Page 7: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 7

NomenclatureUnit Model and Serial Number

R P S 015 D AUnit Model Number

Roofpak: R= Roofpak Applied Rooftop

Unit ConfigurationP= Heating, mechanical coolingF= Heating, future mechanical coolingC= Condensing section only

Singlezone Unit

Nominal Cooling Capacity (Tons)Ex. 015= 15 Tons

Design Vintage

Heating MediumA= Natural GasE= ElectricS= SteamW= Hot WaterY= None (cooling only)

FBO U 09 10 048120Plant Identification AbbreviationFBO = Faribault, MN

Serial Number (build sequence)

U= UnitYear of Manufacture09= 2009, 10= 2010, 11= 2011, 12= 2012, etc.

Month of Manufacture01= Jan.02= Feb.03= Mar.

04= Apr.05= May06= Jun.

07= July08= Aug.09= Sept.

10= Oct.11= Nov.12= Dec.

Serial Number

Page 8: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 8

NomenclatureUnit Code Index 1, 2

General OptionsUnit Model Codes that Pertain: 03, 05, 06, 07, 51- 5623, 25, 33, 61- 72 (Mid 2012 & Later)

Auxiliary Controls/Remote SensorsUnit Model Codes that Pertain: 12, 13, 16, 17, 18

Sections A1, A2Return/Outside Air/Heat Recovery OptionsUnit Model Codes that Pertain: 19, 20, 21, 22, 23 (Mid 2012 & Earlier); 24, 58 (Mid 2012 & Later)

Sections B, C, D, EDrawThru Cooling SectionsSection B- Filter SectionUnit Model Codes that Pertain: 25, 33 (Mid 2012 & Later), 50 (Mid 2012 & Later)

Section C- DrawThru Blank/EmptyUnit Model Codes that Pertain: 14, 15, 26

Section D- DrawThru Cooling Section Unit Model Codes that Pertain: 27, 28

Section E- DrawThru Blank/EmptyUnit Model Codes that Pertain: 30

Section F- Supply Fan OptionsUnit Model Codes that Pertain: 31, 32, 33 (Mid 2012 & Earlier), 59 (Mid 2012 & Later), 14, 15, 49, (all unit sizes)27, 28 (015- 031D only)

Sections G, H, IBlowThru OptionsSection G= BlowThru Heat/Blank/EmptyUnit Model Codes that Pertain: 04, 34

Section H= BlowThru Blank/EmptyUnit Model Codes that Pertain: 38

Section I- BlowThru Cooling SectionsUnit Model Codes that Pertain: 35, 36

Section J- Final Filter SectionUnit Model Codes that Pertain: 39

Section K- Discharge Plenum SectionUnit Model Codes that Pertain: 40

Section L- Out-of-Airstream Blank/Empty SectionUnit Model Codes that Pertain: 41

Section M- Condenser SectionUnit Model Codes that Pertain: 09, 43, 44, 47, 54, 68

Section N- Main Control PanelUnit Model Codes that Pertain: 09, 11, 12, 13, 14, 15, 17, 18, 47 and 23, 54, 68

Section O- Refrigeration TubingUnit Model Codes that Pertain: 45, 46, 48, 54 (Mid 2012 & Later), 68

RPS 015D A W Y 1 EU D 27 AL P1 LE 1 1 S 3 CD S120 BY AE 15F2 EAY Code 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22

1250C Y AB T CYYS 4Z083D YYYYYY BBBBBB 06F2 LKY 1250A W11D3E 23 24 25 26 27 28 29 30 31 32 33 34

CYYS 4Z083D YYYYYY B B BY Y 4 MB R 1 1 1 Y D YYAAY 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50-54

1 An "X" located in ANY position in a code string (ESPECIALLY Code 50 for units built Mid 2012 & Earlier OR Code 60 for units built Mid 2012 & Later) indicates the presence of special feature(s). It is important to note that special features may change unit components in unexpected areas so it is recommended to use the Distributor Tools BOM Search function on the Daikin Parts website or contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified.

2 In mid 2012 the code structure was changed from a 54 code index to a longer more detailed format. A sample 54 Code version is shown above.

Page 9: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 9

NomenclatureUnit Code Index, Continued

Code 03= Cooling Coil SizeY= NoneS= Small face area coilL= Large face area coil

Code 04= Heat Section- Type of HeatY= No HeatA= Natural Gas HeatB= PropaneE= Electric HeatS= Steam HeatW= Hot Water Heat

Code 05= Split UnitY= NoneF= Split at Fan/Heat Sections

Code 06= Insulation and Liners1= 1", 3/4# with Liners on Doors2= 1½", 1.5# with Solid Liners on Doors & Ceilings3= 1½", 1.5# with Perforated Liners in Plenums, solid elsewhere4= 1½", 1.5# with Solid Liners on Doors, Ceilings and Floors5= 1½", 1.5# with Perforated Liners in Plenums, solid elsewhere (including Floor)6= 1½", 1.5# with Stainless Steel Solid Liners on Doors, Ceilings and Floors

Code 07= Approval Agency ListingDigit 1 Y= None E= ETL- USA C= ETL- CanadaDigit 2 Y= None U= UL C= ETL Canada with Low Altitude Burner (less than 2000 feet) D= ETL Canada with High Altitude Burner (over 2000 feet) M= ETL w/ Massachusetts Code Code 08= Main Control Box LocationD= Standard (Discharge Plenum)

Code 09= Unit Voltage12= 208/60/329= 230/60/3 27= 460/60/337= 575/60/3

Code 10= Starting OptionAL= Across-the-Line

Code 11= Field Power Connection and DisconnectDigit 1: Type of Control P= One Power Block - Complete unit A= One Disconnect - Complete unit C= Two Disconnects - Fans/Controls/Unit R= Two Power Blocks - Elect. Heat/UnitDigit 2: Disconnect Mechanism Location 1= Internal 2= Through the door

Code 12= Temperature Control Package MicroTech III Digit 1: Communication Type L= LonWorks B= BACNet w/MSTP E= BACNet w/Ethernet S= Standalone (no communication) C= BACNet/MSTP (VAV Contactor configurable) A= Daikin D3 Gateway (VRV communication) Digit 2: Control Type E= Discharge Air w/ Static Pressure Control F= Space or Zone Ctl. W= Discharge Air w/ Space ControlNo Controls YC= No Temperature Controller w/analog gas actuator YM= No Temperature Controller w/floating point control YA, 1A, 2A= RCS Standalone unit (see RPL form # 7000197 for part information)

Code 13= Air Flow ControlsY= None 1= 1 Duct Sensor2= 2 Duct Sensors 3= 1 Duct &1 Space Sensor 4= 1 Space Sensor5= 1 Duct High Limit Sensor

Code 14= InvertersY= None Separate Section 1= SA Fan only w/ Bypass 2= SA & RA Fans w/ Bypass 4= RA Fan only w/ BypassNo Separate Section 3= SA Fan only w/ Bypass 5= SA & RA Fans w/ Bypass 6= SA Fan w/o Bypass 7= SA & RA Fans no Bypass 8= RA Fan only w/ Bypass 9= RA Fan w/o Bypass

Code 15= Inverter VendorY= None A= ABB Inverter B, S= Daikin Applied InverterG= Graham InverterQ= Schneider InverterR= Reliance InverterF= Field Installed Inverter, MicroTech III controlled

Page 10: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 10

Code 21= Return Air FanDigits 1- 3: Fan Size & Wheel Type 15F= 15" X 15" Forward Curved 24B= 24" Airfoil (Heat Recovery only) 30B= 30" Airfoil 40B= 40" AirfoilDigit 4: Fan Isolation type 1= Rubber-in-shear (RIS) 2= Spring 3= Spring w/Seismic Snubbers

Code 22= Return Air Fan MotorYYY= No Return FanE E Y

Y= NoneS= W/ Shaft Grounding Kit

E= High Eff. ODP motorH= High Eff. Totally-Enclosed motorJ= Premium Eff. ODP motorK= Premium Eff. Totally-Enclosed motor

E= 1.0 HPF= 1.5 HPG= 2.0 HPH= 3.0 HPJ= 5.0 HPK= 7.5 HPL= 10.0 HPM= 15.0 HPN= 20.0 HP

Code 23= Return Air Fan Drive Selection (Mid 2012 & Earlier)YYYYY= No Return Air Fan_ _ _ _ A

Service Factor/Pitch TypeA= Std. SF/Fixed PitchB= 150% SF/Fixed PitchC= Std. SF/Variable PitchD= 150% SF/Variable Pitch

Code 23= Miscellaneous Electrical Options (Mid 2012 & Later)Digit 1: UV Lights Y= None U= UV LightsDigit 2: Plenum/Vestibule Lights Y= None P= Plenum Lights V= Vestibule Lights B= Plenum & Vestibule LightsDigit 3: SpeedTrol, Energy Recover, MHGR VFD Y= None A= ABB B= Daikin Applied Q= SchneiderDigit 4: 115V Service Outlet Y= None F= Factory supplied Line Voltage OutletDigit 5: Power Factor Capacitors / Intelligent Equipment Y= None A= Intelligent Equipment (IE) P= Power Factor Capacitors (RPS only) L= iE Express

Code 24= Heat Wheel Frost ProtectionY= NoneF= Frost Protection Inverter (AFD60)

NomenclatureUnit Code Index, Continued

Code 16= Smoke DetectorsY= None 1= Return Air Only 2= Supply Air Only 3= Supply and Return Air

Code 17= Misc. Auxiliary ControlsDigit 1: Control Type Y= None, includes Mechanical Enthalpy when Code 20= DE, EE, FE, GE, 3E C= Differential Enthalpy (Code 20= DE, EE, FE, GE, 3E)Digit 2: Control Type Y= None F= Freezestat (Steam or HW Heat only) P= Phase Failure G= Ground Fault Protection L= Line Reactors (Inverter w/ separate section only) A= Freezestat & Phase Failure (Steam, HW Heat only) B= Freezestat & Ground Fault (Steam, HW Heat only) C= Phase Failure & Ground Fault D= Freezestat, Phase Failure & Ground Fault (Steam or HW Heat only) E= Freezestat & Line Reactors (Steam or HW Heat & Inverter w/separate sect. only) H= Phase Failure & Line Reactors (Inverter w/ separate section only) J= Freezestat, Phase Failure & Line Reactors (ST, HW Heat & Inverter w/separate sect. only) K= Ground Fault, Phase Failure & Line Reactors (ST, HW Heat & Inverter w/separate sect. only)

Code 18= Misc. Controls/Unit LengthA, S, Y___= None (___= Air Handler Length [in.])K, R___= Remote Keypad (___= Air Handler Length [in.])U___= Unit Powered Receptacle (___= Air Handler Length [in.])V___= K + U (___= Air Handler Length [in.])

Code 19= Return Air PlenumYY= No sectionBY= Bottom Return BB= Bottom Return w/ Burglar BarsBE= Bottom Return w/ Isolation damperHY= Back Return

Code 20= Outdoor Air OptionsYY= NoneAE= 100% Outside air damper w/hood & ActuatorAY= 100% Outside air damper w/hood/no ActuatorBE= 0- 30% Outdoor air section w/ActuatorBY= 0- 30% Outdoor air section w/o ActuatorDE= 0- 100% Econ. w/barometric exhaust damper w/ Act.DY= 0- 100% Econ. w/barometric exhaust damper w/o Act.EE= 0- 100% Econ. w/power closure exhaust damper w/ Act.EY= 0- 100% Econ. w/power closure exhaust damper w/o Act.FE= same as DE + Design FlowFY= same as DY + Design FlowGE= same as EE + Design FlowGY= same as EY + Design Flow1Y= Heat Recovery 100% OA Low Flow w/o Actuator1E= Heat Recovery 100% OA Low Flow w/ Actuator2Y= Heat Recovery 100% OA High Flow w/o Actuator2E= Heat Recovery 100% OA High Flow w/ Actuator3Y= Heat Recovery Economizer w/o Actuator3E= Heat Recovery Economizer w/ Actuator

RequiredRPM

Page 11: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 11

Code 25= DrawThru Filter/Air Blender SectionDigit 1: Section Type A= Angular (22" Section) D= Angular with low CFM Blender (22" & 52" section) E= Angular with high CFM Blender (22" & 52" section) F= Flat (28" Section) G= Flat with low CFM Blender (22" & 52" section) H= Flat with high CFM Blender (22" & 52" section) B= Blank/Empty 22" section C= Blank/Empty 28" sectionDigit 2: Filter Type Y= No Filter media supplied B= Throwaway 30% Efficient C= Throwaway 30% Efficient w/ Intersept H= Throwaway 85% Efficient D= Cartridge 65% Efficient E= Cartridge 95% Efficient G= Cartridge 65% Efficient w/ Intersept Code 26= Blank/Empty DrawThru SectionY= No sectionA= Blank/Empty 22" SectionC, S= Blank/Empty 40" SectionD, T= Blank/Empty 52" Section

Code 27= DrawThru Coil Section/Drain PanDigits 1- 3: Cooling Type YYY= No section CYY= Cooling unit DYY= Drain Pan only (40" section) GYY= Cooling w/ Hot Gas Reheat (40" section) Digit 4: Options S= Std. stainless steel Drain Pan P, Y= Std. painted galvanized steel Drain Pan L= Wide stainless steel Drain Pan (Digits 1- 3= DYY only) T= Wide painted galvanized steel Drain Pan (Digits 1- 3= DYY only) Code 28= Cooling Coil YYYYYY= No Cooling Coil4Z 08 3 D

C= Hi-F Copper Fin (stainless casing)D= Lanced Aluminum Fin (galv. casing)

3= 3 Row4= 4 Row5= 5 Row6= 6 Row

08= 8 Fins-per-inch10= 10 Fins-per-inch12= 12 Fins-per-inch14= 14 Fins-per-inch

4Z= Type 4EZ

NomenclatureUnit Code Index, Continued

Code 29= N/A to RPS, RFS/RCS- Always YYYYYY

Code 30= DrawThru Blank/Empty/Spacer SectionYYYYYY= No sectionAAAAAA= 22" Blank/Empty/Spacer sectionBBBBBB, CCCCC= 40" Blank/Empty/Spacer Section

Code 31= Supply Air FanDigits 1- 3: Fan Size & Wheel Type 06F= 15" X 6" Forward Curved 15F= 15" X 15" Forward Curved 20A= 20" Airfoil 24F= 24" Forward Curved, Low Pressure 24A= 24" AirfoilDigit 4: Fan Isolation type 1= Rubber-in-shear (RIS) 2= Spring 3= Spring w/Seismic Snubbers

Code 32= Supply Air Fan MotorE E Y

Y= NoneS= W/ Shaft Grounding Kit

E= High Eff. ODP motorH= High Eff. Totally Enclosed motorJ= Premium Eff. ODP motorK= Premium Eff. Totally Enclosed motor

E= 1.0 HP K= 7.5 HPF= 1.5 HP L= 10.0 HPG= 2.0 HP M= 15.0 HPH= 3.0 HP N= 20.0 HPJ= 5.0 HP P= 25.0 HP

Code 33= Supply Air Fan Drive Selection (Mid 2012 & Earlier)_ _ _ _ A

Service Factor/Pitch TypeA= Std. SF/Fixed PitchB= 150% SF/Fixed PitchC= Std. SF/Variable PitchD= 150% SF/Variable Pitch

Code 33= Miscellaneous Mechanical Options (Mid 2012 & Later)Digit 1: Gauges Y= None A= Magnehelic/Differential Filter Gauge in DrawThru section B= Magnehelic/Differential Filter Gauge in BlowThru section C= Magnehelic/Differential Filter Gauge in DrawThru & Blow- Thru sectionsDigit 2: California Title 24 Y= None F= Economizer w/ Fault Detection/Diagnosis (FDD)Digit 3: Ebtron Air Flow Measuring S= Ebtron Air Flow (Hybrid) G= Ebtron Air Flow (Gold)Digit 4: Heating Coil Options Y= None E= Electrofin CoatingDigit 5: Cooling Coil Options Y= None E= Electrofin Coating

RequiredRPM

Page 12: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 12

NomenclatureUnit Code Index, Continued

Code 34= BlowThru Heat SectionYYYYYY= No section (cooling unit only)BBBBBB= Blank/Empty 40" sectionGas Heat Breakdown:020 S H A

A= Low CFM Baffle PositionB= Medium CFM Baffle PositionC= High CFM Baffle Position

E= Modulating Burner (3:1)R= Modulating Burner/with H.P. Regulator Range= 2-3 psiS= Modulating Burner/with H.P. Regulator Range= 5-10 psiH= Hi Turn Down Burner (20:1)T= Hi Turn Down Burner with H.P. Reg. Range= 2-3 psiU= Hi Turn Down Burner with H.P. Reg. Range= 5-10 psi

S= Stainless Steel Heat Exchanger

MBH (in 10's)ex. 020= 200 MBH [020,025,032,040,050,064,065,079,080,100]

Electric Heat Breakdown:E 020 1 Y

Always Y

1= 1 Stage2= 2 Stage3= 3 Stage

KW (ex. 020= 20 KW) [020,040,060,080,100,120,140,160, 180]

E= Electric Heat

Hot Water OR Steam Heat Breakdown:W 11 D 3 E

Y= No ActuatorE= Electric Actuator

Y= No Valve2= 2- Way Valve (ST)3= 3- Way Valve (HW)

Y= No ValveD= 1.00" ValveE= 1.25" ValveF= 1.50" ValveG= 2.00" Valve

11= 9 FPI 1 Row (HW) or 6 FPI 1 Row (ST)12= 12 FPI 1 Row (ST)22= 9 FPI 2 Row (HW)

W= Hot Water Heat (HW)S= Steam Heat (ST)

Code 35= BlowThru Coil Section/Drain PanDigits 1- 3: Cooling Type YYY= No section CYY= Cooling unit DYY= Drain Pan only (40" section) GYY= Cooling w/ Hot Gas Reheat (40" section) Digit 4: Options S= Std. stainless steel Drain Pan P, Y= Std. painted galvanized steel Drain Pan L= Wide stainless steel Drain Pan (Digits 1- 3= DYY only) T= Wide painted galvanized steel Drain Pan (Digits 1- 3= DYY only)

Code 36= Cooling CoilYYYYYY= No Cooling Coil4Z 08 3 D

C= Hi-F Copper Fin (stainless casing)D= Lanced Aluminum Fin (galv. casing)

3= 3 Row4= 4 Row5= 5 Row6= 6 Row

08= 8 Fins-per-inch10= 10 Fins-per-inch12= 12 Fins-per-inch

4Z= Type 4EZ

Code 37= N/A to RPS, RFS/RCS- Always YYYYYY

Code 38= BlowThru Blank/Empty Section (Mid 2012 & Earlier)Y= No sectionB= Blank/Empty Section after Heat Section- 40" sectionD= Blank/Empty Section after Heat Section- 52" section

Code 38= Attenuator Section (Mid 2012 & Later)Y= No sectionG= With 36" Std. Straight AttenuatorK= With 36" Std. Straight Attenuator w/ Tedlar CoatingH= With 60" Std. Straight AttenuatorL= With 60" Std. Straight Attenuator w/ Tedlar CoatingJ= Std. Elbow Attenuator M= Std. Elbow Attenuator w/ Tedlar CoatingA= Blank/Empty 22" SectionC= Blank/Empty 40" SectionD= Blank/Empty 52" Section

Code 39= Final Filter SectionY= No sectionA= Flat filter section, 95% cartridge, 28" sectionB= Flat filter section, 95% cartridge, 52" sectionC= Blank/Empty- 28" sectionD= Blank/Empty- 52" sectionE= Flat filter section, 95% cartridge, 28" section with InterseptF= Flat filter section, 95% cartridge, 52" section with InterseptG= Flat filter section, 95% HEPA cartridge, 28" section H= Flat filter section, 95% cartridge, 52" section

Code 40= Discharge Air PlenumDigit 1 B= Bottom F= Front (RFS units only) L, S= LH side (opposite drive side) R= RH side (drive side) Digit 2 Y= None B= Burglar Bars E= Isolation Damper w/Actuator Code 41= Out-of-Airstream Blank/Empty SectionY= No section2= 40" Section Out Of Airstream

Page 13: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 13

NomenclatureUnit Code Index, Continued

Code 42= Compressor Capacity Control2= 2 steps (Size 015 only) 3= 3 steps (Sizes 020- 031) 4= 4 steps (Sizes 035- 042)M= Modulating

Code 43= Condenser OptionsYY= None (RFS units only)Digit 1: Air Coils M= 25mm Microchannel Coil P= 25mm Microchannel Electrofin coated Coil T= 32mm Microchannel coil U= 32mm Microchannel Electrofin coated Coil Y= None Digit 2: Miscellaneous Options G= Coil/Vandal Guards (coated steel) S= Sealtite Conduits B= Coil/Vandal Guards & Sealtite Conduits Y= None

Code 44= Compressor TypeR= Standard Scroll, R410A 1

D= Digital Scroll, R410A 1

Code 45= Compressor IsolationY= None (RFS units only)1= Resilient rubber-in-shear

Code 46= Piping Options Y= None 1= Hot Gas Bypass, Circuit #12= Hot Gas Bypass, Circuit #1 & #23= Replaceable Core Filter Drier4= Hot Gas Bypass Circuit #1 w/Replaceable Filter Drier Core5= Hot Gas Bypass Circuit #1 & 2 w/Replaceable Filter Drier Cores Code 47= Low Ambient OperationY= None (RFS units only)1= FanTrol 2= SpeedTrol (includes FanTrol)3= Quiet Fan + FanTrol 4= Quiet Fan + SpeedTrol5= FanTrol w/ TEAO Motors6= SpeedTrol w/ TEAO Motors

Code 48= IBC Seismic Construction/Hot Gas ReheatY= NoneH= Modulating Hot Gas ReheatA= ASCE 7- 10 Wind CertificationI= Seismic ConstructionK= Modulating Hot Gas Reheat and Seismic ConstructionJ= IBC Seismic Construction- Category E/F

Code 49= Supply and Return Fan OptionsY= NoneA= SA Fan Belt GuardB= SA Fan Section LightC= SA Fan Belt Guard w/ SA Fan Section LightD= SA & RA Fan Belt GuardE= SA & RA Fan Section LightF= SA & RA Fan Belt Guard w/ SA & RA Fan Section Light

Code 50= Miscellaneous (Mid 2012 & Earlier)YY= None XX= Special

Code 50= Blender Section (Mid 2012 & Later)Y= NoneL= Low CFM Blender, 52 Inch SectionH= High CFM Blender, 52 Inch SectionA= Blank/Empty 22" SectionC= Blank/Empty 40" SectionD= Blank/Empty 52" Section

Code 51= Packaging (Mid 2012 & Earlier) 1= Steel Skid2= Consolidated Ship

Code 51= Draw=Thru Pre-Heat Section (Mid 2012 & Later)YYYYY= NoneAAAAAA= Blank/Empty 22" SectionCCCCCC= Blank/Empty 40" SectionDDDDDD= Blank/Empty 52" SectionW 11 D 3 E

Y= No ActuatorE= Electric Actuator

Y= No Valve2= 2- Way Valve (ST)3= 3- Way Valve (HW)

Y= No ValveD= 1.00" ValveE= 1.25" ValveF= 1.50" ValveG= 2.00" Valve

11= 9 FPI 1 Row (HW) OR 6 FPI 1 Row (ST)12= 12 FPI 1 Row (ST)13= 06 FPI 2 Row (ST)14= 12 FPI 2 Row (ST)22= 9 FPI 2 Row (HW)

W= Hot Water Heat (HW)S= Steam Heat (ST)

Code 52= Parts Warranty (Mid 2012 & Earlier)A= Standard One Year PartsC= Extended One Year Parts, Two Year TotalD= Extended Two Year Parts, Three Year TotalE= Extended Three Year Parts, Four Year TotalF= Extended Four Year Parts, Five Year TotalZ= Special

Code 52= Drain Pan/Humidifier Section (Mid 2012 & Later)YY= NoneAA= Blank/Empty 22" SectionCC= Blank/Empty 40" SectionDD= Blank/Empty 52" Section DH= Humidifier w/stainless steel Drain Pan 40" sectionDY= Stainless steel Drain Pan only, 48" section

Code 53= Compressor Warranty (Mid 2012 & Earlier)Y= None (RFS units only)A= Standard One Year PartsQ= Extended Four Year Compressor, Five Year Total

Code 53= Custom Specifications (Mid 2012 & Later)YY= None RR= "B" vintage replacement unit

1 Note that there are some Digital Scroll Compressor units built as SPECIALS (Code 44= R AND Code 60= XX with Digital Scroll compressors listed as a special feature). Refer to the Condenser Section (Section M) Notes for more information on Digital Scroll Compressor units.

Page 14: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 14

NomenclatureUnit Code Index, Continued

Code 54= Heat Exchanger Warranty (Mid 2012 & Earlier)Y= None (Code 04 CANNOT= A)A= Standard One Year Heat ExchangerR= Extended Nine Year Heat Exchanger, Ten Year Total

Code 54= Hot Gas/Liquid Subcool Reheat (Mid 2012 & Later)YY= None BM= BlowThru Modulating Hot Gas Cir. #2 (includes SpeedTrol)ML= Modulating Liquid Subcool Reheat Circuits #1 & 2 BL= BlowThru Modulating, Hot Gas Circuit #2, AND Modulating Liquid Subcool Reheat Circuits #1 & 2)

Code 55= Ultra High Efficiency UnitsYY= NoneHE= Ultra High Efficiency Unit (016D, 021D, 026D, 031D)

Code 56= Chicago Code/Refrigeration Service ValvesYY= None CC= Chicago CodeYV= Refrigeration Service ValvesCV= Chicago Code w/ Refrigeration Service Valves Code 57= N/A to RPS, RFS/RCS- Always YY

Code 58= Return Air Fan Drive Selection_ _ _ _ A

Service Factor/Pitch TypeA= Std. SF/Fixed PitchB= 150% SF/Fixed PitchC= Std. SF/Variable PitchD= 150% SF/Variable Pitch

Code 59= Supply Air Fan Drive Selection_ _ _ _ A

Service Factor/Pitch TypeA= Std. SF/Fixed PitchB= 150% SF/Fixed PitchC= Std. SF/Variable PitchD= 150% SF/Variable Pitch

Code 60= Misc. SpecialsYY= NoneXX= Special

Code 61= Packaging/ASHRAE Certification 1= Steel Skid2= Consolidated Ship3= Steel Skid w/ ASHRAE Certification4= Consolidated Ship w/ ASHRAE Certification

Code 62= Parts WarrantyA= Standard One Year PartsC= Extended One Year Parts, Two Year TotalD= Extended Two Year Parts, Three Year TotalE= Extended Three Year Parts, Four Year TotalF= Extended Four Year Parts, Five Year TotalZ= Special

Code 63= Compressor WarrantyY= None (RFS units only)A= Standard One Year PartsQ= Extended Four Year Compressor, Five Year Total

RequiredRPM

RequiredRPM

Code 64= Heat Exchanger WarrantyY= None (Code 04 CANNOT= A)A= Standard One Year Heat ExchangerR= Extended Nine Year Heat Exchanger, Ten Year Total

Code 65= Unit Family027C= 015D- 030D037C= 035- 042D

Code 66= Drain ConnectionY= None L= Left Side (opposite drive side)R= Right Side (drive side)

Code 67= ASHRAE Certification Y= None B= AHRI Certified-90.1 2010C= AHRI Certified-90.1 2013D= AHRI Certified-90.1 2016

Code 68= Short Circuit Current Rating YY= None 10= 10 SCCR 22= 22 SCCR 65= 65 SCCR

Code 69= Labor WarrantyDigit 1: Unit Labor A= One Year B= Two Year C= Three Year D= Four Year E= Five Year Y= None Z= SpecialDigit 2: Compressor Labor A= One Year B= Two Year C= Three Year D= Four Year E= Five Year Y= None Z= Special

Codes 70- 72 N/A to RPS/RDT/RFS/RCS- Always YYYYYYYY

Page 15: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 15

Unit Layout DiagramsUnit Section Layout 1

1 The Unit Section Layout Diagrams shown above are to be used for reference only. Unit sections and component locations may vary depending on unit size, configuration, and options selected.

1.5" NPT Drain

Condensercontrol panel (RCS only)

Page 16: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 16

Unit Layout DiagramsControl Location 1

1 RPS Units shown for reference. Controls and control locations may vary depending on unit configuration, size, and options selected.

Page 17: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 17

Schematic Sym. Description Location ACT3, 4 Actuator Motors, Economizer Economizer Section ACT5 Actuator Motor, Discharge Isolation Damper Discharge Section ACT6 Actuator Motor, Return Air Isolation Damper Return Air Section ACT7 Actuator Motor, Heat Face/Bypass Coil Section, Heat ACT8 Actuator Motor, Cool Face/Bypass Coil Section, Cool ACT10, 11 Actuator Motors, Exhaust Dampers Return Air Section ACT12, 13 Actuator Motor, Enthalpy Wheel Bypass Damper Energy Recovery Section AS Airflow Switch, Burner Blower Gas Heat Box BM Burner Blower Motor Furnace Section C1- C4 Power Factor Capacitors, Compressors Condenser Section C10 Power Factor Capacitors, Supply Fan Supply Air Section C20 Power Factor Capacitors, Return Fan Return Air Section CB10 Circuit Breaker, Supply Fan Main Control Box CB20 Circuit Breaker, Return/Exhaust Fan Main Control Box CB60 Circuit Breaker, Energy Recovery Wheel Main Control Box COMPR1- 4 Compressors Condenser Section DAT Discharge Air Temperature Sensor Discharge section DCC Digital Compressor Controller Main Control Box DFLH Design Flow Sensor, Left Hand Return Section DFRH Design Flow Sensor, Right Hand Return Section DHL Duct High Limit Main Control Box DS1 Disconnect, Total Unit or Condenser/Heat Main Control Box DS2 Disconnect, SAF/RAF/Controls Main Control Box DS3 Disconnect, Electric Heat Electric Heat Section DS4 Disconnect, Condenser (RCS only) RCS Control Box DS6 Disconnect, Factory Powered Outlet Condenser Section EAT Exhaust Air Temperature Sensor Energy Recovery Section EFT Entering Fan Air Temperature Sensor Supply Fan Section ERM1, 2 Energy Recovery Wheel Motors Energy Recovery Section EXPA, B, C Expansion Boards Main Control Box F1A, B Fuses, Control Circuit Transformer, (T1) Primary Main Control Box F1C Fuse, Control Circuit Transformer, (T1) Secondary Main Control Box F2 Fuse, Control Circuit Transformer, (T2) Primary Main Control Box F3 Fuse, Burner Blower Motor Main Control Box F6A, B Fuses, Transformer, (T6) Primary Condenser Section F6C Fuse, Transformer, (T6) Secondary Condenser Section F12A, B Fuses, Digital Compressor Transformers Main Control Box FB10 Fuseblock, Supply Air Fan Main/Cond. Control Box FB11, 12, 21, 22 Fuseblocks, SpeedTrol Main/Cond. Control Box FB20 Fuseblock, Return Air Fan Main/Cond. Control Box FB31- 40 Fuseblocks, Electric Heat (Top Bank) Electric Heat Box FB41- 50 Fuseblocks, Electric Heat (Bottom Bank) Electric Heat Box FB60 Fuseblock, Energy Recovery Wheel Main/Cond. Control Box FD Flame Detector Furnace Section FLC Fan Limit Control Furnace Section FP1, 2 Frost Protection, Refrigeration Circuits Coil Section, Cool FS1, 2 Freezestat Control Coil Section, Heat/Cool FSG Flame Safeguard Gas Heat Box GFR1, 2 Ground Fault Relays Main Control Box GFS1, 2 Ground Fault Sensors Main Control Box GFR4 Ground Fault Relay, Condenser Condenser Control Box GFS4 Ground Fault Sensor, Condenser Condenser Control Box GRD Ground All Control Boxes

Electrical Legend

Page 18: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 18

Electrical LegendContinued

GV1 Gas Valve, Pilot Furnace Section GV2 Gas Valve, Main/Safety Furnace Section GV3 Gas Valve, Redundant/Safety Furnace Section GV4- 8 Gas Valve, Main, Hi-Turn Down Furnace Section HL 1- 10 High Limits, Power, Electric Heaters (Top Bank) Electric Heat Section HL 11- 20 High Limits, Power, Electric Heaters (Bottom Bank) Electric Heat Section HL22 High Limit, Gas Heat (Prefilters) Supply Air Section HL23 High Limit, Gas Heat (Final Filters) Final Filter Section HL31- 40 High Limits, Control, Electric Heaters (Top Bank) Electric Heat Section HL41- 50 High Limits, Control, Electric Heaters (Bottom Bank) Electric Heat Section HP1- 4 High Pressure Controls, Refrigerant Compr./Press./Cond. Box HP5 High Pressure Control, Gas Furnace Section HS1 Heat Switch, Electric Shutdown Main Control Box HS3 Heat Switch, Electric Heat Deadfront Interlock Electric Heat Box HTR1- 4 Crankcase Heaters On Compressors HUM1 Humidistat Sensor Energy Recovery Section IT Ignition Transformer Furnace Section LAT Temperature Sensor, Leaving Air Energy Recovery Section LP1- 4 Low Pressure Controls, Refrigerant On Compr./Cond. Box LP5 Low Pressure Control, Gas Furnace Section LR10 Line Reactor, Supply Fan Inverter Bypass Box LR20 Line Reactor, Return/Exhaust Fan Inverter Bypass Box LR11, 21 Line Reactors, Condenser Fan SpeedTrol Pressure/Cond. Box LS1, 2 Limit Switches, Low/High Fire Furnace Section LT10 Light, Supply Fan Supply Air Section LT11 Light, Return Fan Return Air Section LT12 Light, Heat Section Heat Section LT13 Light, Filter Section Filter Section LT14 Light, Final Filter Section Final Filter Section LT15 Light, Discharge Section Discharge Section LT16 Light, Blow-through Coil Section BlowThru Coil Section LT17 Light, Evaporator Coil Section Evaporator Coil Section LT18 Light, Preheat Section Preheat Section LT19 Light, Blank/Empty Section Blank/Empty Section LT20 Light, Blank/Empty Section Blank/Empty Section LT21 Light, DrawThru Coil Section DrawThru Coil Section LT22 Light, Condenser Section Condenser Section M1-4 Contactors, Compressors Main/Cond. Control Box M10 Contactor, Supply Fan Main Control Box M11- 18 Contactors, Condenser Fans, Circuit #1 Main/Cond. Control Box M20 Contactor, Return Fan Main Control Box M21- 28 Contactors, Condenser Fans, Circuit #2 Main/Cond. Control Box M29 Contactor, Burner Motor Furnace Section M30 Contactor Reversing, Inverter Bypass, Supply Fan Inverter Bypass Box M31- 39 Contactors, Elec. Heaters (Top Bank) Electric Heat Section M40 Contactor, Reversing, Inverter Bypass, Return Fan Inverter Bypass Box M41- 50 Contactors, Elec. Heaters (Bottom Bank) Electric Heat Section M60, 61 Contactors, Energy Recovery Wheel Motor Main Control Box MCB Microtech III Control Board Main Control Box MJ Mechanical Jumpers All Control Boxes MMP1- 4 Manual Motor Protectors, Compressors Main/Cond. Control Box

Schematic Sym. Description Location

Page 19: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 19

Electrical LegendContinued

MMP10 Manual Motor Protector, Supply Fan Main Control Box MMP11- 18 Manual Motor Protectors, Condenser Fans Ckt. 1 Main/Cond. Control Box MMP20 Manual Motor Protector, Return fan Main Control Box MMP21- 28 Manual Motor Protectors, Condenser Fans Ckt. 2 Main/Cond. Control Box MMP30 Manual Motor Protector, Inverter Bypass Supply Fan Inverter Bypass Box MMP40 Manual Motor Protector, Inverter Bypass Return Fan Inverter Bypass Box MMP51- 53 Manual Motor Protectors, Exhaust Fan(s) Prop Exhaust Box MMP60, 61 Manual Motor Protector, Energy Recovery Wheel Main Control Box MP1- 4 Motor Protectors, Compressors On Compressors OAE Enthalpy Control, Outside Air Economizer Section OAT Temperature Sensor, Outside Air Economizer Section OL61 Overload- Energy Recovery Wheel (575V) Main/Cond. Control Box PB1, 2 Power Block, Power Distribution Main Control Box PB3 Power Block, Power Distribution, Electric Heat Electric Heat Section PB4 Power Block, Power Distribution, Condenser (RCS only) Cond. Control Box PB9, 10 Power Blocks, Supply Fan Junction Box, Split Unit PB11, 12 Power Blocks, Power Distribution Main Control Box PB19, 20 Power Blocks, Return/Exhaust Fan Junction Box, Split Unit PC5 Pressure Control, Clogged Filter Pre Filter Section PC6 Pressure Control, Clogged Final Filter Final Filter Section PC7 Pressure Control, Proof of Airflow Supply Air Section PC13, 23 Pressure Controls, FanTrol Pressure/Cond. Box PC29 Pressure Control, Coil Splitter Pressure/Cond. Box PT11, 21 Pressure Transducers, SpeedTrol Pressure/Cond. Box PVM1, 2 Phase Voltage Monitors Main Control Box PVM 4 Phase Voltage Monitor, Condenser (RCS only) Condenser Control Box R1- 2 Relays, High Pressure Reset (RCS only) RCS Control Box R5- 8 Relays, Safety (RCS only) RCS Control Box R31- 36 Relays, Compressor Staging (RCS only) RCS Control Box R11 Relay, Cond. Fan 11 SpeedTrol Inverter Enable Pressure/Cond. Box R12- 14 Relays, FanTrol Condenser Fan Cycling Main/Cond. Control Box R17 Relay, Cond. Fan 21 SpeedTrol Inverter Enable Pressure/Cond. Ctrl. Box R20 Relay, Gas/Steam/Hot Water Furn./Main Ctrl. Box R21, 22 Relays, Gas Heat, 20:1 High Turndown Furn./Main Ctrl. Box R23 Relay, Gas Heat Furnace Section R24 Relay, Gas Heat Alarm Main Control Box R25 Relay, Gas Heat, Start Supply Fan Inverter Main Control Box R26 Relay, Isolation/Exhaust Dampers Main Control Box R28 Relay, Isolation Damper Safety Main Control Box R45 Relay, UV Lights Main Control Box R63 Relay, Special (No Ctrls.), Duct High Limit (DHL) MTIII Main Control Box R70- 89 Relays, Specials Main Control Box RAE Enthalpy Sensor, Return Air Return Air Section RAT Temperature Sensor, Return Air Return Air Section REC1 Receptacle, Main Box Main Control Box REC2 Receptacle, Condenser Box Cond. Control Box REC3 Receptacle, Field Power, 115VAC Discharge Bulkhead REC10- 23 Receptacles, Cabinet Sections Cabinet Sections RHB1, 2 Interface Board, Modulating Hot Gas Reheat Main Control Box S1 Switch, System On/Off Main Control Box S2 Switch, System On/Off, RCS Unit Cond. Control Box

Schematic Sym. Description Location

Page 20: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 20

Electrical LegendContinued

Schematic Sym. Description Location S3 Switch, Furnace On/Off Furnace Section S4 Switch, Inverter Bypass On/Off Main Control Box S40- 45 Switches, Door Interlock, UV Lights Cabinet Sections SC11 Speed Control, Circuit #1 Cond. Bulkhead SC21 Speed Control, Circuit #2 Cond. Bulkhead SD1 Smoke Detector, Supply Air Discharge Section SD2 Smoke Detector, Return Air Return Air Section SHS1 Sensor, Space Humidity Return Section (Field inst.) SPS1, 2 Sensors, Static Pressure, Duct or Building Main Control Box SV1, 2 Solenoid Valves, Liquid Condenser Section SV7 Solenoid Valve, Digital Compressor Condenser Section T1 Transformer, Main Control, Line/115VAC Main Control Box T2 Transformer, Control Input, 115/24VAC Main Control Box T3 Transformer, Control Output, 115/24VAC Main Control Box T6 Transformer, Factory Powered outlet, Line/115VAC Condenser Section T7 Transformer, Hot Gas Reheat, 115/24VAC Main Control Box T11 Transformer, SpeedTrol, Line/240VAC Condenser Section TB1 Terminal Block, Internal for Transformers Main Control Box TB2 Terminal Block, Field Main Control Box TB3 Terminal Block, Factory, 115/24VAC Main Control Box TB4 Terminal Block, Field, 115VAC Main Control Box TB5 Terminal Block, RCS Field, 115V Condenser Control Box TB6 Terminal Block, RCS Field Condenser Control Box TB7 Terminal Block, 115VAC Convenience Outlet Main Control Box TB8 Terminal Block, RCS, 115VAC Convenience Outlet Condenser Control Box TB11 Terminal Block, Heating Furn./Elect. Heat Ctrl. Box TB25- 28 Terminal Blocks, Split Unit Junction Box Split Unit Junction Box TB35, 36 Terminal Blocks, Digital Compressor Main Control Box TC12- 14 Temperature Controls, FanTrol Condenser Section TD1, 2 Time Delays, Compressor Lockout (RCS only) Condenser Control Box TD20 Time Delay, Return Air Fan Main Control Box TR1, 2 Transducer, Pressure, SpeedTrol Main Control Box UV Ultra-Violet Light(s) Coil/Discharge Section VFD/AFD10 Adjustable Frequency Drive, Supply Fan DrawThru/Supply Section VFD/AFD11, 21 Adjustable Frequency Drive, Cond. Fan SpeedTrol Pressure/Cond. Ctrl. Box VFD/AFD20 Adjustable Frequency Drive, Return/Exhaust Fan Dr. Thru/Ret./Exh. Section VFD/AFD60 Adjustable Frequency Drive, Energy Recovery Wheel Energy Recovery Section VM1 Valve Motor #1, Heating Furnace/Heating Section VM5 Valve Motor #5, Cooling Coil Section, Cooling VV1 Vent Valve, Gas Heat Furnace Section ZNT1 Sensor, Zone Temperature Field Installed

Page 21: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 21

Section A1- Outdoor/Return Air SectionNotes➩

Primary Codes that pertain: 19, 20, 21, 22, 23 (Mid 2012 & Earlier), 58 (Mid 2012 & Later)Additional Codes that pertain: 06, 09, 12, 14, 15, 16, 17, 23 (Mid 2012 & Later), 33, 48, 49

Codes 19 and 20 determine the base section. Code 19 is the Return Air Plenum and determines if the unit has back/horizontal return air or bottom return air. A Return Air Plenum is required for any outdoor air application with an Economizer (Code 20= BE, BY, DE, DY, EE, EY, FE, FY, GE, GY). The only case in which a Plenum is not required is when a 100% Outdoor Air Damper and Hood are ordered (Code 20= AE, AY). For units with Heat Recovery (Code 20= 1*, 2*, 3*) see Section A2.

Code 21 determines the Return Fan size and type, Code 22 determines the Motor horsepower and type; and Code 23 (Mid 2012 & Earlier) OR 59 (Mid 2012 & Later) determine the drive selection. These codes only pertain to units with a 0- 100% Economizer (Code 20= DE, DY, EE, EY, FE, FY, GE, GY). The Return Air Fan section parts, the Fans, and Motors are listed in this section. Drive components (Fan Sheave, Motor Sheave, V-belt[s], and Sheave Bushing[s]- if required) are NOT listed as they are unique to the unit. If a drive component is required you may use the number from the part and cross reference it in the Daikin Applied Parts catalog, The Daikin Parts E-Commerce site, or contact Daikin Applied with model and serial number information.

Code 06, insulation and liners, influences the final cabinet assembly panel part numbers. For sheet metal components that make up the Outdoor/Return Air Section, contact Daikin Applied with model and serial number information to ensure correct liners, insulation and hardware are ordered. For standard Access Door Latching Assemblies, see Section H.

Code 09, unit voltage, is part of the Return Fan Motor part number identification.

Code 12, the control system, comes into play when an Economizer is present. The Economizer is supplied with an Actuator on MicroTech equipped units, but MAY OR MAY NOT come with a factory supplied Actuator if the unit has controls by others (Code 12= YM, YC).

Codes 14 & 15 determine if the unit has a Return Air Fan Inverter/AFD/VFD and if so where it is installed. If Code 14= 5, 7, 8, 9, the inverter is installed in the Supply Air Section. If Code 14= 2, 4 there is a separate Inverter Section. If Code 14= Y, there are no inverters. Code 15 specifies the inverter vendor, or if the inverter was field supplied and controlled by the Microtech III Controller.

Code 16 determines if the unit has a Smoke Detector located in the Return Air cabinet. If Code 16= 1, 3 a Smoke Detector (SD2) is present.

Code 17 determines the type of Enthalpy and Miscellaneous Auxiliary Controls included. The second digit of Code 17 lists the inclusion of Freezstats, Phase Failure, Line Reactors, and Ground Fault protection.

Code 23 (Mid 2012 & Later) indicates the presence of UV/Plenum/Vestibule Lights, the SpeedTrol/Heat Wheel/MHGR inverter brand specified, and/or the presence of Intelligent Equipment.

Code 33 (Mid 2012 & Later) indicates the presence of a Magnehelic/Differential Filter Gauge in a DrawThru or BlowThru section. Refer to Section B (DrawThru Filter Section) for the Gauge part number and description. Code 33 also indicates if the unit is California Title 24 compliant and/or equipped with Ebtron Air Flow Monitors. When Code 33= **S**, **G** an Ebtron Airflow Monitoring Air Monitoring system has been installed. For Ebtron p/ns, contact Daikin Applied with model and serial number information so that the correct part(s) can be identified.

Code 48 determines if the unit is equipped with IBC seismic construction.

Code 49 determines if the Return Air Cabinet has a Light (Code 49= E), Fan Belt Guards (Code 49= D) or both (Code 49= F).

Page 22: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 22

Section A1- Outdoor/Return Air Section100% Outside Air Damper with HoodCode 20= AE, AY AND Code 19= YY

No Return Air Plenum

Ref. Part With Actuator Without Actuator Qty. No. Description C20= AE C20= AY 4 Damper Assembly 1 098313601 098313601 1 6 Hood 058440303 058440303 1 14 Channel 058436501 058436501 1

14

SectionB

6

4

1 This Damper assembly does NOT include an Actuator or Actuator Linkage. A list of component parts follows this page.

Page 23: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 23

Section A1- Outdoor/Return Air Section100% Outside Air Damper with HoodCode 20= AE, AY AND Code 19= YY

13 2527 28

29

31A23

21

Manual Linkage Detail:

C20= AY

22

2416

187

35

14

26

6A

74

20

Damper Assy Detail

MotorizedLinkage Detail:

C20= AE

Ref. Part Part Number Qty. No. Description C20= AE C20= AY Damper Assy 098313601 098313601 1 4 Linkage Rod 067012700 067012700 1 6 Crank Arm Operator 066302059 Not Used 1 6A Arm Shaft Not Used 065371301 1 7 Linkage Rod 067012800 067012800 1 11 Actuator Support 403699401 Not Used 1 13 Damper Blade 044195101 044195101 12 14 Damper Seal 055616401 055616401 4 16 Damper Stop 065779801 065779801 2 17 Bearing Support Not Used 066002401 1 18 Linkage Bar 047149800 047149800 2 20 Crank Arm Not Used 025072600 1 21 Ball Joint 000887000 000887000 4 22 Actuator Motor ACT3 113139501 1 Not Used 1 23 Bushing 046098300 046098300 12 24 Bushing 043730400 043730400 24 25 Gasket 044193114 044193114 12 26 Gasket 045655714 046555714 1 27 Damper End Plug 041003501 041003501 12 28 Damper End Plug 041003502 041003502 6 29 Damper End Plug 041003503 041003503 6 31 Bearing 047138504 Not Used 1 31A Lock Collar Not Used 049115902 2 35 Retainer Bracket 403633801 Not Used 1 38 Nut, Hex 040499904 040499904 4

1

1

21

638

31 11

21

4

38

17

1 Units built early in production used a different Actuator. This is the recommended replacement. When replacing an original actuator minor field modifications may be required for proper installation and operation.

Page 24: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 24

Section A1- Outdoor/Return Air Section0- 30% Outside Air Section Damper

Code 20= BE, BY AND Code 19= BY, HY

Linkage Detail:

Without ActuatorC20= BY

Linkage Detail:With

ActuatorC20= BE

Ref. Part Part Number Qty. No. Description C20= BE C20= BY Damper Assembly 1 403671301 058440322 1 1 Damper 2 098314101 098314101 1 8 Damper Blade 044193213 044193213 2 9 Gasket 055940213 055940213 1 10 Gasket 044193132 044193132 2 11 End Seal 058456701 058456701 2 13 Motor Support 058456501 Not Used 1 13A Rod Support Angle Not Used 055608601 1 14 Linkage Bar 058456601 058456601 1 15 Shaft Linkage 055536606 055536606 1 26 Exhaust Louver 096170531 096170531 1 N/S Screen Only 058434301 058434301 2 30 End Plug 041003505 041003505 2 31 End Plug 041003506 041003506 2 32 Bushing 043730400 043730400 4 33 Bushing 046098300 046098300 4 34 Ball Joint 000887000 000887000 2 35 Actuator Motor ACT3 113139501 3 Not Used 1 36 Damper Crank Arm 403666401 Not Used 1 37 Mounting Plate 403667001 Not Used 1 42 Screw- .19-24 x .75 046093803 046093803 4 43 Screw- .25-20 x 1.00 046296600 046296600 4 48 Retainer 403633801 Not Used 1

Damper Detail

N/S= Not shown on diagram.1 Assembly includes Damper, Damper Linkage, and Actuator (Code 20= BE) OR

Damper and Linkage only (Code 20= BY).2 Damper only, no Linkage or Actuator components.3 Units built early in production used a different Actuator. This is the recommended

replacement. When replacing an original actuator minor field modifications may be required for proper installation and operation.

32

13A

34

36

35

15

34

13

151

143

14

3342

8

30

1426

11 9

10

31

37

48

Page 25: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 25

Section A1- Outdoor/Return Air Section0- 100% Economizer Section with Exhaust Damper

Units without Return Air FansCode 20= DE, DY, EE, EY, FE, FY, GE, GY AND Code 21= YYYY

160

100

Back Return (Code 19= HY) shown.

Ref. Part Part Qty. No. Description Number 100 Economizer Damper Assembly 1 w/ Act.(Code 20= DE, EE, FE, GE, KE) 2 1 w/o Act. (Code 20= DY, EY, FY, GY, KY) 2 1 160 Exhaust Damper & Baffle Assembly Powered (Code 20= EE, EY, GE, GY) 3 058440320 1 Damper Only 4 112040427 1 Barometric (Code 20= DE, DY, FE, FY, KE, KY) 5 058440310 1 Damper Only 6 112039627 11 Economizer Damper ONLY (NO Actuator or Actuator Linkage) p/n 098312801 detail is three pages after next. 2 For the complete Damper Assembly including Actuator and Linkage contact Daikin Applied with model and serial

number information so that the correct assembly can be identified.3 Includes the Damper, Damper Actuator, and Side Baffles.4 Includes the Damper, Damper Actuator, and Side Baffles.5 Includes the Damper and Side Baffles.6 Damper ONLY.

Page 26: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 26

Section A1- Outdoor/Return Air Section0- 100% Economizer Section with Exhaust Damper

Units with 15" Forward Curved Return Air FansCode 20= DE, DY, EE, EY, FE, FY, GE, GY AND Code 21= 15**

Unit Sizes 015- 030D only

12

11124

54

150

125

55

Bottom Return (Code 19= BY, BB) shown.

Ref. Part Part Qty. No. Description Number 11 0- 100% Economizer Damper 1 098312801 1 Actuator/linkage Assy (C20= DE) 403633001 1 Actuator Only 113139501 3 1 Linkage Assy. w/o act. (C20= DY) 058400805 1 12 Damper Assy Barometric (C20= DE, DY, FE, FY) 058440310 1 Power (C20= EE, EY, GE, GY) 058440320 1 Damper Only 112039627 1 54 Gasket 023530463 1 55 Gasket 023530416 2 124 Belt Guard- LH 2 058440381 1 125 Belt Guard- RH 2 058440382 1 150 Deflection Screen 046446600 11 This Damper assembly does not include an Actuator or Actuator Linkage. A

list of component parts is three pages previous to this page.2 Code 49= D, F. 3 Units built early in production used a different Actuator. This is the

recommended replacement. When replacing an original actuator minor field modifications may be required for proper installation and operation.

Page 27: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 27

Section A1- Outdoor/Return Air Section0- 100% Economizer Section with Exhaust Damper

Units with 30" Air Foil Return Air FansCode 20= DE, DY, EE, EY, FE, FY, GE, GY AND Code 21= 30**

Ref. Part Part Qty. No. Description Number 11 0- 100% Economizer Damper 1 098312801 1 Actuator/linkage Assy (C20= DE) 403633001 1 Actuator Only 113139501 3 1 Linkage Assy. w/o act. (C20= DY) 058400805 1 12 Damper Assy Barometric (C20= DE, DY, FE, FY) 058440310 1 Power (C20= EE, EY, GE, GY) 058440320 1 Damper Only 112039627 1 50 Belt Guard 2 058400888 2 55 Gasket 055921422 2

12

11

55

5550

Bottom Return (Code 19= BY, BB) shown.

1 This Damper assembly does not include an Actuator or Actuator Linkage. A list of component parts is four pages previous to this page.

2 Code 49= D, F. 3 Units built early in production used a different Actuator. This is the

recommended replacement. When replacing an original actuator minor field modifications may be required for proper installation and operation.

Page 28: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 28

Section A1- Outdoor/Return Air Section0- 100% Economizer Section with Exhaust Damper

Units with 40" Air Foil Return Air FansCode 20= DE, DY, EE, EY, FE, FY, GE, GY AND Code 21= 40**

Unit Sizes 035- 042D only

Ref. Part Part Qty. No. Description Number 11 0- 100% Economizer Damper 1 098312801 1 Actuator/linkage Assy (C20= DE) 403633001 1 Actuator Only 113139501 3 1 Linkage Assy. w/o act. (C20= DY) 058400805 1 12 Damper Assy Barometric (C20= DE, DY, FE, FY) 058440314 1 Power (C20= EE, EY, GE, GY) 058440324 1 Damper Only 112039627 1 50 Belt Guard 2 058400888 2 55 Gasket 055921422 2 124 Fan Guard 2 058440384 2

12

Bottom Return (Code 19= BY, BB) is only option for 40" RAF.

55

11

124

55

50

1 This Damper assembly does not include an Actuator or Actuator Linkage.2 Code 49= D, F. 3 Units built early in production used a different Actuator. This is the

recommended replacement. When replacing an original actuator minor field modifications may be required for proper installation and operation.

Page 29: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 29

Section A1- Outdoor/Return Air Section0- 100% Economizer Assembly

Code 20= D*, E*, F*, G*Diagrams

1214

10

9

13 25 27 28 29

1216

15

19

23

24

8

18

11

22

20

17

421

6A

11A

7

21

Without ActuatorCode 20= DY, EY, FY, GY

6

3

26

3531

4

21

19

19

With ActuatorCode 20= DE, EE, FE, GE

721

31A

Page 30: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 30

Section A1- Outdoor/Return Air Section0- 100% Economizer Assembly

Code 20= D*, E*, F*, G*Components

Ref. Part Part Number Qty. No. Description C20= *E C20= *Y Damper Assembly 1 098312801 098312801 1 3 Channel 058440313 058440313 1 4 Linkage Rod 112977101 067012700 1 6 Crank Arm Operator 066302059 Not Used 1 6A Arm Shaft Not Used 065371301 1 7 Linkage Rod 112977401 067012800 1 8 Bottom Support 058448201 058448201 1 9 Top Support 058448401 058448401 1 10 Block Off 058449601 058449601 1 11 Motor Mount 403633801 Not Used 1 11A Rear Bearing Support Not Used 066002101 1 12 Side Support 058448301 058448301 2 13 Damper Blade 044195101 044195101 12 14 Outside Seal 043734500 043734500 4 15 Center Seal 043734400 043734400 2 16 Damper Stop 065779801 065779801 4 17 Front Bearing Supp. Not Used 066002201 1 18 Linkage Bar 044194800 044194800 2 19 Linkage Bar 044194900 044194900 2 20 Crank Arm Not Used 025072600 1 21 Ball Joint 000887000 000887000 4 22 Actuator Motor ACT3 113139501 2 Not Used 1 23 Bushing 046098300 046098300 12 24 Bushing 043730400 043730400 24 25 Gasket 044193114 044193114 12 26 Gasket 045655714 045655714 2 27 End Plug 041003501 041003501 12 28 End Plug 041003502 041003502 6 29 End Plug 041003503 041003503 6 31 Bearing 047138504 Not Used 1 31A Locking Collar Not Used 049115902 2 35 Mount 403634601 Not Used 11 This Damper assembly does not include an Actuator or Actuator Linkage. 2 Units built early in production used a different Actuator. This is the

recommended replacement. When replacing an original actuator minor field modifications may be required for proper installation and operation.

Page 31: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 31

Section A1- Outdoor/Return Air SectionCalifornia Title 24 Assembly

Code 33 (Mid 2012 & Later) = *F***

Ref. Part Part Qty. No. Description Number 3533 Cover, Mounting Switch 404159561 1 3534 Bracket, Mounting Switch 404159562 1 3535 Switch, Push Button SPDT 033696300 2 3536 Bushing, Conduit 113116301 1

3533

3536

3534

3535

Page 32: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 32

Section A1- Outdoor/Return Air SectionReturn Air Plenum Isolation Damper w/ Actuator ACT6

Code 19= BE AND Code 21= 15F* 3

Unit Sizes 015- 031D

Ref. Part Part Qty. No. Description Number 110 Damper Assembly 24 x 82" w/ ACT6 403721701 1 3 Motor Mount 910143614 2 1 4 Damper Blade 403721201 5 18 Damper Linkage 055536606 1 20 Actuator Motor- ACT6 113144901 1 21 Damper Shaft 403717101 1 22 Damper Ball Joint 000887000 2 24 Damper Blade Gasket 029870900 1

26 Retainer 403716801 2 1 27 Bearing, sleeve flange 403717301 2 1

4

110

24

320

2721

26

20

18

21

22

22

1 The Damper Gasket is sold in 10 foot lengths. 6.66 feet required per Blade.2 Note that the design of the ACT6 mounting components was changed in mid 2013. It is

recommended that the when replacing the actuator mount that the new design be used. Minor field modifications are required for proper installation and operation.

3 For units with 24" Fans (Code 21= 24B*) OR 40" Fans (Code 21= 40B*) use the Distributor Tools BOM Search function on the Daikin Parts website or contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified.

Page 33: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 33

Section A1- Outdoor/Return Air SectionReturn Air Plenum Isolation Damper w/ Actuator ACT6

Code 19= BE AND Code 21= 30B* 3

Ref. Part Part Qty. No. Description Number 110 Damper Assembly 30 x 76" w/ ACT6 910134136 1 3 Motor Mount 910143614 2 1 4 Damper Blade 059404314 6 18 Damper Linkage 055536601 1 20 Actuator Motor- ACT6 113144901 1 21 Damper Shaft 403717101 1 22 Damper Ball Joint 000887000 2 24 Damper Blade Gasket 029870900 1

26 Retainer 910143679 2 1 27 Bearing, sleeve flange 047138504 2 1

4

110

24

1 The Damper Gasket is sold in 10 foot lengths. 6.66 feet required per Blade.2 Note that the design of the ACT6 mounting components was changed in mid 2013. It is

recommended that the when replacing the actuator mount that the new design be used. Minor field modifications are required for proper installation and operation.

3 For units with 24" Fans (Code 21= 24B*) OR 40" Fans (Code 21= 40B*) use the Distributor Tools BOM Search function on the Daikin Parts website or contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified.

320

2721

26

20

18

21

22

22

Page 34: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 34

Section A1- Outdoor/Return Air SectionDesign Flow

Code 20= FE, FY, GE, GY

Ref. Part Part Qty. No. Description Number Louver Panel 1 Units with no Return Fan (40" Door) Left Hand Door 058410204 7 Units with no Return Fan (40" Door) Right Hand Door 058410203 7 Units with 30" OR 40" Return Fan (52" Door) Left Hand Door 058565104 7 Units with 30" OR 40" Return Fan (52" Door) Right Hand Door 058565103 7 Grille 2 Units with no Return Fan (40" Door) 058410401 1 Units with 30" OR 40" Return Fan (52" Door) 058564001 1 3 Gasket 026172804 3 9 Potentiometer 098663701 1 12 O-Ring- Potentiometer 098663801 1 104 Panel- Vane 098661801 1 105 Shaft- Upper 098662601 1 106 Bearing- Lower 091634501 1 109 Crank Arm Assy Left Hand Door 091658802 1 Crank Arm Assy Right Hand Door 091658801 1 110 Link Arm 1 1 120 Bearing 060014201 1 127 Bearing 047138535 1 130 Spring- Main 098664801 1 131 Spring- Secondary 098664901 1 N/S Leveling Kit- Design Flow 091659301 1

2

9 127

12

110120 109 104

105

106

131

130104

1

Section Final Assembly

Design Flow Vane and Vane Bearings Detail

Adjuster Control AssyDetail

SpringDetail

LH Louvered Door Assy

RH Louvered Door Assy

Louvered DoorAssembly Detail

3

1 P/N is unit specific. Contact Daikin Applied with overall length and bolt hole spacing so that the correct part can be identified.

Page 35: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 35

Section A1- Outdoor/Return Air SectionReturn Air Fan Mounting- 15" Forward Curved Fan

Code 21= 15F1, 15F2, 15F3

Ref. Part Part Qty.1

No. Description Number 21 Support Mount 055512101 1 61 Isolator R- 3 Black 021639704 1 81 Clinch Nut 059992201 2 89 Screw 112047201 2 91 Nut 032333305 3 92 Screw 040499501 2

61

21

92

91

1 Drawing is common to all four corners. Quantities listed are for ONE mount.

Rubber-In-Shear (RIS) Mount Code 21= 15F1

81

Spring Mount Code 21= 15F2 AND Seismic Mount Code 21= 15F3 Ref. Part Part Qty.2

No. Description Number 21 Spring Mount- Standard 251783201 1 Spring Mount- Seismic 251783301 1 3

61 Spring Isolator- Position 3 Standard Motor H.P.= 1 thru 3 251784501 1 Motor H.P.= 5 thru 7.5 251784701 1 Motor H.P.= 10 251784601 1 Spring Isolator- Position 3 Seismic 3

Motor H.P.= 1 thru 3 251784501 1 Motor H.P.= 5 thru 7.5 251784601 1 Motor H.P.= 10 251784701 1 62 Spring Isolator- Position 4 Standard Motor H.P.= All 251784501 1 Spring Isolator- Position 4 Seismic 3

Motor H.P.= All 251784501 1 63 Spring Isolator- Position 2 Standard Motor H.P.= 1 thru 3 251784601 1 Motor H.P.= 5 thru 7.5 251784801 1 Motor H.P.= 10 251784701 1 Spring Isolator- Position 2 Seismic 3

Motor H.P.= 1 thru 3 251784601 1 Motor H.P.= 5 thru 7.5 251784701 1 Motor H.P.= 10 251784801 1 64 Spring Isolator- Position 1 Standard Motor H.P.= All 251784601 1 Spring Isolator- Position 1 Seismic 3

Motor H.P.= All 251784601 1 81 Clinch Nut- Standard 059992201 3 Clinch Nut- Seismic 111056301 5 3

88 Nut 040500002 1 89 Screw- Standard 112047201 3 Screw- Seismic 112047201 5 3

63 Pos. 2 61

64 62

Top View Air

Flow

91

81

89

Seismic strap used only when Code 21= 15F3.

Pos. 3

Pos. 4Pos. 1

21

61 62

63 64

88

89

2 Drawing is common to all four corners. Quantities listed are for ONE mount.3 This part is used when Code 21= 15F3.

Page 36: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 36

Section A1- Outdoor/Return Air SectionReturn Air Fan Mounting- 30" and 40" Airfoil FanCode 21= 30B1, 40B1, 30B2, 40B2, 30B3, 40B3

Spring Mount Code 21= 30B2, 40B2 AND Seismic Mount Code 21= 30B3, 40B3 Diagram

Ref. Part Part Qty.1

No. Description Number 21 Support Mount 055512101 1 61 Isolator R- 3 Black 021639704 1 81 Clinch Nut 059992201 2 89 Screw 112047201 2 91 Nut 032333305 3 92 Screw 040499501 2 93 Washer 040500310 2

61

21

92

91

1 Drawing is common to all four corners. Quantities listed are for ONE mount.

Rubber-In-Shear (RIS) Mount Code 21= 30B1, 40B1

91

81

89

81

63 Pos. 2 61

64 62

Top View Air

Flow

Seismic strap used only when Code 21= **B3.

Pos. 3

Pos. 4Pos. 1

21

61 62

63 64

88

89

93

Page 37: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 37

Section A1- Outdoor/Return Air SectionReturn Air Fan Mounting- 30" and 40" Airfoil Fan

Code 21= 30B2, 30B3

Ref. Part 30" Qty. 1

No. Description Fan 21 Spring Mount- Standard 251783201 1 Spring Mount- Seismic 251783301 1 2

61 Spring Isolator- Position 3 Standard Motor H.P.= 1 thru 3 251784601 1 Motor H.P.= 5 thru 10 251784701 1 Spring Isolator- Position 3 Seismic 2

Motor H.P.= 1 thru 3 251784601 1 Motor H.P.= 5 thru 10 251784701 1 62 Spring Isolator- Position 4 Standard Motor H.P.= All 251784401 1 Spring Isolator- Position 4 Seismic 2

Motor H.P.= All 251784401 1 63 Spring Isolator- Position 2 Standard Motor H.P.= 1 thru 5 251784601 1 Motor H.P.= 7.5 thru 10 251784701 1 Spring Isolator- Position 2 Seismic 2

Motor H.P.= 1 thru 7.5 251784601 1 Motor H.P.= 10 251784701 1 64 Spring Isolator- Position 1 Standard Motor H.P.= All 251784401 1 Spring Isolator- Position 1 Seismic 2

Motor H.P.= All 251784401 1 81 Clinch Nut- Standard 059992201 3 Clinch Nut- Seismic 111056301 5 2

88 Nut 040500002 1 89 Screw- Standard 112047201 3 Screw- Seismic 112047201 5 2

Spring Mounting Code 21= 30B2, and Seismic Mount Code 21= 30B3 Components

1 Quantity shown is for ONE mount.2 This part is used only when Code 21= 30B3.

Page 38: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 38

Section A1- Outdoor/Return Air SectionReturn Air Fan Mounting- 30" and 40" Airfoil Fan

Code 21= 40B2, 40B3

Ref. Part 40" Qty. 1

No. Description Fan 21 Spring Mount- Standard 251783201 1 Spring Mount- Seismic 251783301 1 2

61 Spring Isolator- Position 3 Standard Motor H.P.= 1 thru 5 251784701 1 Motor H.P.= 7.5 thru 10 251784801 1 Spring Isolator- Position 3 Seismic 2

Motor H.P.= 1 thru 5 251784701 1 Motor H.P.= 7.5 thru 10 251784801 1 62 Spring Isolator- Position 4 Standard Motor H.P.= 1 thru 5 251784501 1 Motor H.P.= 7.5 thru 10 251784601 1 Spring Isolator- Position 3 Seismic 2

Motor H.P.= 1 thru 5 251784501 1 Motor H.P.= 7.5 thru 10 251784601 1 63 Spring Isolator- Position 2 Standard Motor H.P.= 1 thru 5 251784601 1 Motor H.P.= 7.5 thru 10 251784701 1 Spring Isolator- Position 2 Seismic 2

Motor H.P.= 1 thru 5 251784601 1 Motor H.P.= 7.5 thru 10 251784701 1 64 Spring Isolator- Position 1 Standard Motor H.P.= All 251784501 1 Spring Isolator- Position 1 Seismic 2

Motor H.P.= All 251784501 1 81 Clinch Nut- Standard 059992201 3 Clinch Nut- Seismic 111056301 5 2

88 Nut 040500002 1 89 Screw- Standard 112047201 3 Screw- Seismic 112047201 5 2

Spring Mounting Code 21= 40B2, and Seismic Mount Code 21= 40B3 Components

1 Quantity shown is for ONE mount. 2 This part is used only when Code 21= 40B3.

Page 39: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 39

Section A1- Outdoor/Return Air SectionReturn Air Fan Deck

15" Fans: Code 21= 15F1, 15F2, 15F3

6

38

8

2726

15

1919A

13

7Motor 121 25

Ref. Part Part Qty. No. Description Number 6 Wheel/Housing Assy. 033135100 2 7 Motor Shelf 033262600 1 8 Filler Piece 033262400 1 13 Shaft 033262001 1 15 Tube Coupling 027674000 3 N/S Tube Clamp 001324600 4 19 Grease Fitting/Zerk 000109800 3 19A Coupling/Reducer 027674100 3 21 Shim 2 3 25 Ball Bearing 020648601 3 26 Key 023221409 2 27 Key 023221405 1 38 Motor Mount Bolt 010507200 2N/S= Not shown on diagram.1 Motors are listed after the fan deck details.2 Shims are used as needed. Any of the following may be used:

025639900 (.058"); 091531301 (.046"); 091531601 (0.22"); 091531501 (.031").

Page 40: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 40

Section A1- Outdoor/Return Air SectionReturn Air Fan Deck

30" Fans: Code 21= 30B1, 30B2, 30B3

1

6

7 Motor 1

1

1719

2

1719

Ref. Part Part Qty. No. Description Number 1 Bearing 020648601 2 2 Funnel- Inlet 031940902 1 6 Wheel- Fan 066543221 1 7 Mount- Motor 058400974 1 13 Shaft- Fan 058568201 1 17 Tubing- Plastic 021136745 2 19 Fitting- Grease 000109800 2 19A Fitting- Reducer 027674100 2 26 Key 023221405 1 27 Key 023221411 1

132627

1 Motors are listed after the fan deck details.

19A

Page 41: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 41

Section A1- Outdoor/Return Air SectionReturn Air Fan Deck

40" Fans: Code 21= 40B1, 40B2, 40B3

67

2

25

2726

13

1516

194

9 Motor 1

25

5

1516

19

Ref. Part Part Qty. No. Description Number 2 Inlet Funnel 031940905 1 4 Bearing Support 058400982 1 5 Lower Bearing Support 058400983 1 6 Fan Wheel: SISW 066543242 1 7 Fan Motor Mount 058400974 1 9 Baffle 055963002 1 10 Support 056197201 1 13 Shaft 037788701 1 15 Coupling 027674000 2 16 Coupling 027674100 2 17 Plastic tubing 021136745 2 19 Grease Fitting 000109800 2 25 Bearing 020648603 2 26 Shaft Key 023221508 1 27 Shaft Key 023221507 11 Motors are listed after the fan deck details.

17

10

17

Page 42: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 42

H.P. Motor H.P. Unit ODP HiEff ODP PrEff TEFC HiEff TEFC PrEff Motor Code 22= Voltage C22= *EY C22= *JY C22= *HY C22= *KY Mount 1

C09= 12 1 E*Y 208/60/3 039447400 205167600 049100100 004735000 073316603 1.5 F*Y 208/60/3 039442200 205167500 049100200 046513100 073316604 2 G*Y 208/60/3 039895700 046515500 049100300 073321000 073316604 3 H*Y 208/60/3 039447500 065817100 047358100 065819400 073316605 5 J*Y 208/60/3 039447600 065817200 049186800 065819500 073316606 7.5 K*Y 208/60/3 037530300 065817300 047665900 065819600 073316607 10 L*Y 208/60/3 038999000 065817400 047666100 065819700 073316608 15 M*Y 208/60/3 039896200 065817500 049186900 065819800 073316609 20 N*Y 208/60/3 039895800 065817600 049187000 065819900 073316610 C09= 29 1 E*Y 230/60/3 039446200 205162800 040161000 046513000 073316603 1.5 F*Y 230/60/3 039442300 046511100 040161100 046513100 073316604 2 G*Y 230/60/3 039446300 205163500 047446000 073321000 073316604 3 H*Y 230/60/3 039442400 065818100 049262300 065820100 073316605 5 J*Y 230/60/3 039442500 065818200 040161200 065820200 073316606 7.5 K*Y 230/60/3 039448700 065818300 049100500 065820300 073316607 10 L*Y 230/60/3 039446500 065818400 044691100 065820400 073316608 15 M*Y 230/60/3 039446600 065818500 038689700 065820500 073316609 20 N*Y 230/60/3 039448800 065818600 040161300 065820600 073316610 C09= 27 1 E*Y 460/60/3 039446200 205162800 040161000 046513000 073316603 1.5 F*Y 460/60/3 039442300 046511100 040161100 046513100 073316604 2 G*Y 460/60/3 039446300 205163500 047446000 073321000 073316604 3 H*Y 460/60/3 039442400 065818100 049262300 065820100 073316605 5 J*Y 460/60/3 039442500 065818200 040161200 065820200 073316606 7.5 K*Y 460/60/3 039448700 065818300 049100500 065820300 073316607 10 L*Y 460/60/3 039446500 065818400 044691100 065820400 073316608 15 M*Y 460/60/3 039446600 065818500 038689700 065820500 073316609 20 N*Y 460/60/3 039448800 065818600 040161300 065820600 073316610 C09= 37 1 E*Y 575/60/3 049180800 206500900 049188000 206505600 073316603 1.5 F*Y 575/60/3 049180900 206501600 049188100 205167800 073316604 2 G*Y 575/60/3 049181000 205168300 049188200 046514400 073316604 3 H*Y 575/60/3 046741600 046511700 049188300 046514500 073316605 5 J*Y 575/60/3 046741900 205168900 049188400 046514600 073316606 7.5 K*Y 575/60/3 047443300 205168800 049188500 046514700 073316607 10 L*Y 575/60/3 047443400 205168600 049188600 065821400 073316608 15 M*Y 575/60/3 047443500 205166600 049185200 065821500 073316609 20 N*Y 575/60/3 049181100 205166800 049188700 065821600 0733166101 Note that the Return Fan Motor Mounts listed are used ONLY in Heat Recovery units built 04/2012 & Earlier when Code

21= 24B* AND Code 20= 1*, 2*, 3*. See 24" Return Fan Detail (Section A2).

Section A1- Outdoor/Return Air SectionReturn Air Fan Motors

Standard Motors: Code 22= **Y

Page 43: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 43

Section A1- Outdoor/Return Air SectionReturn Air Fan Motors

Shaft Grounded Motors: Code 22= **S 1

H.P. Motor HP Unit ODP PrEff TEFC PrEff C22= **S Voltage C22= *JS C22= *KS C09= 12 1 E*S 208/60/3 205167699 N/A 1.5 F*S 208/60/3 205167599 N/A 2 G*S 208/60/3 046515599 N/A 3 H*S 208/60/3 300052109 065819499 5 J*S 208/60/3 300052118 065819599 7.5 K*S 208/60/3 065817399 065819699 10 L*S 208/60/3 065817499 065819799 15 M*S 208/60/3 065817599 065819899 20 N*S 208/60/3 065817699 065819999 C09= 29 1 E*S 230/60/3 300049695 300049685 1.5 F*S 230/60/3 300049696 300049686 2 G*S 230/60/3 300049697 300049687 3 H*S 230/60/3 300049698 300049688 5 J*S 230/60/3 300049699 300049689 7.5 K*S 230/60/3 300049700 300049690 10 L*S 230/60/3 300049701 065820499 15 M*S 230/60/3 065818599 300049198 20 N*S 230/60/3 065818699 300049691 C09= 27 1 E*S 460/60/3 300049695 300049685 1.5 F*S 460/60/3 300049696 300049686 2 G*S 460/60/3 300049697 300049687 3 H*S 460/60/3 300049698 300049688 5 J*S 460/60/3 300049699 300049689 7.5 K*S 460/60/3 300049700 300049690 10 L*S 460/60/3 300049701 065820499 15 M*S 460/60/3 065818599 300049198 20 N*S 460/60/3 065818699 300049691 C09= 37 1 E*S 575/60/3 206500999 206505699 1.5 F*S 575/60/3 206501699 205167899 2 G*S 575/60/3 205168399 046514499 3 H*S 575/60/3 046511799 205168499 5 J*S 575/60/3 205168999 046514699 7.5 K*S 575/60/3 205168899 046514799 10 L*S 575/60/3 205168699 065821499 15 M*S 575/60/3 205166699 065821599 20 N*S 575/60/3 205166899 065821699N/A= Not Available.1 For Return Fan Motor Mounts used in Heat Recovery units (when Code

21= 24B* AND Code 20= 1*, 2*, 3*. See 24" Return Fan Detail (Section A2).

Page 44: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 44

Ref. Part Part Qty. No. Description Number 30 Smoke Detector- SD2 098873101 1

Ref. Part Part Qty. No. Description Number 40 Mount- OAE Enthalpy 1 1 41 Control- OAE 1 1

Section A1- Outdoor/Return Air SectionSection Mounted Controls

OAE, RAE, LT11, S11, REC11

40

Ref. Part Part Qty. No. Description Number 84 Light Fixture 6/13 & Earlier 042229500 1 Light Fixture 7/13 & Later 910145007 1 85 Bulb- LT11 065492402 1 88 Light Switch- S11 065492201 1 89 Receptacle- REC11 030187000 1

LT11- Return Fan Light/S11- Return Fan Light Switch/REC11- Return Fan Light ReceptacleCode 49= E, F

OAE- Mechanical Enthalpy (Code 17= Y*)

41

84 85

88 89

Ref. Part Part Qty. No. Description Number 40 Mount- OAE Enthalpy 2 1 41 Control- OAE 2 1 42 Mount- RAE Enthalpy 2 1 48 Control- RAE 2 1

OAE & RAE Differential Enthalpy (Code 17= C*)

48

42

Economizer Damper

Return Air Opening

30

Return Air

Opening

30SD2- Return Air Smoke DetectorCode 16= 1, 3

Back ReturnCode 19= HY

Bottom ReturnCode 19= BY, BE

Bottom ReturnShown

Code 19= BY, BE

Bottom ReturnShown

Code 19= BY, BE

7

Ref. Part Part Qty. No. Description Number 7 Sensor- RAT 193414602 1

RAT- Return Air Temperature Sensor

1 The original control is obsolete & no longer available. For the OAE Control use p/n 113103601 & Mount 910146257. Minor field modifications are required for proper installation & operation when changing to the newer design.

2 BOTH original controls are obsolete & no longer available. For the OAE Control use 113103601 & Mount 910146257. For the RAE Control use 113103701 & Mount 055732301. Note that when changing out EITHER ONE of the older style controls BOTH CONTROLS MUST BE CHANGED TO THE NEWER VERSION. When upgrading to the new style controls, field modifications, including the installation of Relay 349934722 (OAER), are required for proper installation & operation.

Economizer Damper

40

41

Page 45: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 45

Section A2- Outdoor/Return Air w/ Heat Recovery SectionNotes➩

Primary Codes that pertain: 19, 20, 21, 22, 23 (Mid 2012 & Earlier); 24, 58 (Mid 2012 & Later)Additional Codes that pertain: 06, 09, 14, 15, 16, 17, 48, 49; 23, 33 (Mid 2012 & Later)

Codes 19 and 20 determine the base section and Return Air Plenum. Code 20 determines the type of Outdoor Air/Heat Recovery control used. Code 20= 1*, 2* are 100% OA Air units, and if Code 20= 3* the unit has an Economizer.

Codes 21, 22, 23 (Mid 2012 & Earlier), AND/OR 58 (Mid 2012 & Later) determine the Return Air Fan, Fan Motor, and drive selection. The fan section parts, Fans, and Motors are listed in this section. Drive components (Fan Sheave, Motor Sheave, V-belt[s], and Sheave Bushing[s]- if required) are NOT listed as they are unique to the unit. If a drive component is required you may use the number from the part and cross reference it in the Daikin Applied Parts catalog, The Daikin Parts E-Commerce site, or contact Daikin Applied with model and serial number information.

Code 24 determines if the Heat/Energy Recovery Wheel has a Frost Protection Inverter (VFD60).

Code 06, insulation and liners, influences the final cabinet assembly panel part numbers. For sheet metal components that make up the Outdoor/Return Air With Heat Recovery Section, contact Daikin Applied with model and serial number information to ensure correct liners, insulation and hardware are ordered. For standard Access Door Latching Assemblies, see Section H.

Code 09, the voltage, is part of the Return Fan Motor part number identification.

Codes 14 & 15 determine if the unit has a Return Air Fan Inverter and if so where it is installed. If Code 14= 5, 7, 8, 9, the inverter is installed in the Supply Air Section. If Code 14= 2, 4, there is a separate Inverter Section. If Code 14= Y, there are no inverters. Code 15 determines the Inverter Vendor. For Inverter part numbers, refer to the Supply Air Section (Section F).

If Code 16= 1, 3 a Smoke Detector (SD2) is present in the Return Air Cabinet.

Code 17 determines the type of Enthalpy and Miscellaneous Auxiliary Controls included. The second digit of Code 17 lists the inclusion of Freezstats, Phase Failure, Line Reactors, and Ground Fault protection.

Code 23 (Mid 2012 & Later) indicates the presence of UV/Plenum/Vestibule Lights, the SpeedTrol/Heat Wheel/MHGR inverter brand specified, and/or the presence of Intelligent Equipment.

Code 33 (Mid 2012 & Later) indicates the presence of a Magnehelic/Differential Filter Gauge in a DrawThru or BlowThru section. Refer to Section B (DrawThru Filter Section) for part number and description. When Code 33= **S**, **G** an Ebtron Airflow Monitoring Air Monitoring system has been installed. For Ebtron p/ns, contact Daikin Applied with model and serial number information so that the correct part(s) can be identified.

Code 48 determines if the unit is equipped with IBC seismic construction.

Code 49 determines if the Return Air Cabinet has a Light (Code 49= E), Fan Belt Guards (Code 49= D) or both (Code 49= F).

Page 46: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 46

Section A2- Outdoor/Return Air w/ Heat Recovery Section100% Outside Air Low Flow- Code 20= 1E

202

12

146

201

Intake Hood (see detail to left)

161

204

155

160

148

Outdoor Air Intake Hood Detail

Ref. Part Part Qty. No. Description Number 1 Fan Assembly 1 12 Damper Assy.- Low Leak 2 110905009 1 140 Panel, Top- Hood 111066001 1 141 Panel, LH Side- Outdoor Air Intake Hood 111066101 1 142 Panel, RH Side- Outdoor Air Intake Hood 111066601 1 144 Panel, Louver- Outdoor Air Intake Hood 111066301 1 145 Panel, Louver- Outdoor Air Intake Hood 111066401 1 146 Panel, Lower Louver- Outdoor Air Intake Hood 111066501 1 148 Screen- Outdoor Air Intake Hood 111076501 2 155 Gasket 024476500 8 ft. 160 Wheel, Enthalpy- Heat Recovery 3 1 161 Motor- Enthalpy Wheel 3 1 162 Sheave- Fixed 3 1 201 Filter Rack 110907301 1 202 Filter Rack 110907302 1 204 Filter Rack 110907304 1 206 Filter Rack 110907306 1 418 Door, Indented- Exhaust LH 111201841 1 419 Door, Indented- Exhaust RH 111201842 1 422 Exhaust Hood 111069501 2 N/S Filter 16 x 20 x 2 031298001 12 N/S Filter 16 x 25 x 2 031298002 12

206

141145

142144

148140

162

1

N/S= Not Shown on Diagram.1 See Detail two pages after next.2 See Detail four pages after next.3 See Detail in this section (A2) titled "Heat Recovery-Enthalpy-Wheel Detail (Ref #160) Wheel Motor, Drive Components, Seals".

Exhaust HoodDetail

419418

422

or

LH RH

Page 47: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 47

Section A2- Outdoor/Return Air w/ Heat Recovery Section100% Outside Air High Flow- Code 20= 2E

202

12

146 201

Hood (see detail to left)

161

204

155

160

148

Outdoor Air Intake Hood Detail

Ref. Part Part Qty. No. Description Number 1 Fan Assembly 1 12 Damper Assy.- Low Leak 2 110905009 1 140 Panel, Top- Hood 111066001 1 141 Panel, LH Side- Outdoor Air Intake Hood 111066101 1 142 Panel, RH Side- Outdoor Air Intake Hood 111066601 1 144 Panel, Louver- Outdoor Air Intake Hood 111066301 1 145 Panel, Louver- Outdoor Air Intake Hood 111066401 1 146 Panel, Lower Louver- Outdoor Air Intake Hood 111066501 1 148 Screen- Outdoor Air Intake Hood 111076501 2 155 Gasket 024476500 14 ft. 160 Wheel, Enthalpy- Heat Recovery 3 2 161 Motor- Enthalpy Wheel 3 2 162 Sheave- Fixed 3 2 201 Filter Rack 110907301 1 202 Filter Rack 110907302 1 203 Filter Rack 110907303 1 204 Filter Rack 110907304 1 418 Door, Indented- Exhaust LH 111201841 1 419 Door, Indented- Exhaust RH 111201842 1 422 Exhaust Hood 111069501 2 N/S Filter 16 x 20 x 2 031298001 12 N/S Filter 16 x 25 x 2 031298002 12

203

141145

142144

148140

162

1

N/S= Not Shown on Diagram.1 See Detail one page after next.2 See Detail four pages after next.3 See Detail in this section (A2) titled 'Heat Recovery-Enthalpy-Wheel Detail (Ref #160) Wheel Motor, Drive Components, Seals".

Exhaust HoodDetail

419418

422

or

LH RH

Page 48: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 48

Section A2- Outdoor/Return Air w/ Heat Recovery SectionEconomizer- Code 20= 3E

202

12146

201

Intake Hood

161

155160

148

Outdoor Air Intake Hood

Detail

Ref. Part Part Qty. No. Description Number 1 Fan Assembly 1 12 Damper Assy.- Low Leak 2 Outdoor Air (w/ ACT3) 110905009 1 12A Damper Assy.- Low Leak 2 Return Air (w/ ACT4) 110905009 1 140 Panel, Top- Hood 111066001 1 141 Panel, LH Side- Outdoor Air Intake Hood 111066101 1 142 Panel, RH Side- Outdoor Air Intake Hood 111066601 1 144 Panel, Louver- Outdoor Air Intake Hood 111066301 1 145 Panel, Louver- Outdoor Air Intake Hood 111066401 1 146 Panel, Lower Louver- Outdoor Air Intake Hood 111066501 1 148 Screen- Outdoor Air Intake Hood 111076501 2 155 Gasket 024476500 8 ft. 160 Wheel, Enthalpy- Heat Recovery 3 1 161 Motor- Enthalpy Wheel 3 1 162 Sheave- Fixed 3 1 201 Filter Rack 110907301 1 202 Filter Rack 110907302 1 204 Filter Rack 110907304 1 205 Filter Rack 110907305 1 230 Damper Assy.- Bypass 4 110919907 1 418 Door, Indented- Exhaust LH 111201841 1 419 Door, Indented- Exhaust RH 111201842 1 422 Exhaust Hood 111069501 2 N/S Filter 16 x 20 x 2 031298001 12 N/S Filter 16 x 25 x 2 031298002 12

205

141145

142144

148140

162

1

N/S= Not Shown on Diagram.1 See Detail on next page.2 See Detail two pages after next.3 See Detail in this section (A2) titled "Heat Recovery-Enthalpy-Wheel Detail (Ref #160) Wheel Motor, Drive Components, Seals".4 See Detail three pages after next.

230

12A204

Exhaust Hood Detail

419418

422

or

LH RH

Page 49: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 49

Section A2- Outdoor/Return Air w/ Heat Recovery Section24" Return Fan Detail: (04/12 & Earlier)Code 21= 24B* AND Code 20= 1*, 2*, 3*

40

41

Thrust Restraint Detail

Ref. Part Part Qty. No. Description Number 1 Motor- Return Fan 1

2 Mount- Motor 1

7 Gasket 240488213 1 10 Fan Wheel and Housing Assembly 209989901 1 10A Shaft Only 010288108 1 10B Bearing Only 020648652 1 10C Wheel Only 010255211 1 40 Angle- Thrust Restraint 110916701 2 41 Spring Mount, Floor- Thrust Restraint Red 175 lb. 059397901 2 N/S Spring Mount- Screw 046093820 4 2

N/S= Not shown on diagram.1 See Return Fan Motor Tables for p/ns.2 Two screws are required per mount.

2

1

7

10B

10C

10A

10

Fan Assy, Motor and Motor Mounting

Page 50: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 50

Section A2- Outdoor/Return Air w/ Heat Recovery Section24" Return Fan Detail: (05/12 & Later)

Code 21= 24B* AND Code 20= 1*, 2*, 3*

Ref. Part Part Qty. No. Description Number 1 Motor- Return Fan 1

16 Mount- Motor 205979614 1 72 Inlet Funnel 113172024 1 411 Bearing- Ball, 1.687" 020648652 2 1 412 Bearing- Ball, 1.687" 020648652 2 1 432 Shaft, 1.687" 113174324 1 434 Key- Shaft 023221410 1 452 Wheel, 24" AF 206007724 11 See Return Fan Motor Tables for p/ns.2 Some units may have had setscrew locking style bearings installed. This concentric locking collar style bearing is the

recommended replacement.

16

411

432

1

412

72

434452

Page 51: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 51

Section A2- Outdoor/Return Air w/ Heat Recovery Section24" Return Fan Detail: (04/2012 & Earlier)

Fan Mounts35B35C

35D 35A

81

84

84

87

86

45

Spring Mount Code 21= 24B2 OR Spring w/ Seismic Snubber Code 21= 24B3

Fan Mounting LocationsTop View

Rubber- In- Shear (RIS) Mount Code 21= 24B1

762504226

35A 35B 35C 35D

441 227 510

37

35A 35B

35C35D

Ref. Part Part Qty. No. Description Number 35A Vibration Mount Black 073310701 1 35B Vibration Mount Black 073310701 1 35C Vibration Mount 1 thru 2 HP Green 073310501 1 3 thru 20 HP Black 073310701 1 35D Vibration Mount Black 073310701 1 81 Nut- Hex 032333305 4 84 Nut- Hex 032333304 8 226 Screw 046093820 8 227 Screw 040501412 8 441 Nut- Hex 032333304 4 504 Washer 040500310 8 510 Washer 040500307 8 762 Support- Green Vibration Mount 057862501 1/mt Support- Black Vibration Mount 057862601 1/mt

Ref. Part Part Qty. No. Description Number 35A Vibration Mount Red 059397901 1 35B Vibration Mount Red 059397901 1 35C Vibration Mount 1 HP Black 059397801 1 1.5- 5 HP Red 059397901 1 7.5- 20 HP Green 059398001 1 35D Vibration Mount 1.5- 5 HP Red 059397901 1 7.5- 20 HP Green 059398001 1 37 Mount- Seismic 059478401 4 1

45 Channel 251799501 4 81 Nut- Hex 032333305 8 84 Nut- Hex Spring (C21= 24*2) 032333304 8 Nut- Hex Seismic (C21= 24*3) 032333304 16 1

85 Bolt 047441313 4 86 Screw- Cap 048878118 8 1

87 Washer 040500308 8 1

81

1 Seismic snubber parts. Used only when Code 21= 24B3.

Page 52: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 52

36

35 34

37

41

49

41

40

Fan Mounting Locations

Spring (Code 21= 24B2) ORSpring w/ Seismic Snubber (Code 21= 24B3)

38

Top View

50

44

43

40

34 35

36 37

Ref. Part Part Qty. No. Description Number 34- 37 Spring- 1.5- 10 HP Yellow 251784601 4 34, 35 Spring- 15- 20 HP Green 251784701 2 36, 37 Spring- 15- 20 HP Yellow 251784601 2 38 Mount- Std. (Code 21= 24B2) 251783201 4 38 Mount- Seismic (Code 21= 24B3) 251783301 4 40 Nut 059992201 24 41 Screw 112047201 8

Seismic strap used only when Code 21= 24B3.

34 35

36 37

38

Section A2- Outdoor/Return Air w/ Heat Recovery Section24" Return Fan Detail: (05/2012 & Later)

Fan Mounts

Rubber-In-Shear (Code 21= 24B1) Ref. Part Part Qty. No. Description Number 34- 37 Mount- RIS 021639701 4 38 Mount- Channel 404079350 4 40 Nut 059992201 24 41 Screw 112047201 2 43 Screw, Cap 040499501 8 44 Nut 032333305 8 49 Washer 040500310 4 50 Screw, Cap 040499501 4

Page 53: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 53

Section A2- Outdoor/Return Air w/ Heat Recovery SectionLow Leak Damper Detail, Part No. 110905009 (Ref. #12 OR 12A)Damper, Actuator (ACT3 - OA Damper and ACT 4 - RA Damper)

122

119

127

116

114

126

127

125

128

129

120

116

128

ACT3 OR ACT4

Ref. Part Part Qty. No. Description Number Complete Assy. w/ Actuator 110905009 Complete Assy. w/o Actuator 251868001 114 Seal- End 043734303 2 116 Stop- Damper 047110101 2 119 End Plug 057783404 1 120 Blade- Damper 047793306 3 122 Actuator ACT3, 4 24V 113139501 1 1 125 End Plug 041003508 3 126 End Plug 041003509 2 127 Bushing- Linkage 046098300 6 128 Bushing- Damper Blade 043730400 5 129 Shaft- Drive 043734000 21 Units built early in production used a different Actuator. This is the

recommended replacement. When replacing an original actuator minor field modifications may be required for proper installation and operation.

Page 54: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 54

Section A2- Outdoor/Return Air w/ Heat Recovery SectionLow Leak Bypass Damper Detail, Part No. 110919907 (Ref. #230)

Damper, Actuator (ACT12)Economizer Units (Code 21= 3E)

122

117127

133

114

ACT12

126

127

119

125

129

120

116

128

Ref. Part Part Qty. No. Description Number Complete Assy. w/ Actuator 110919907 Complete Assy. w/o Actuator 251868401 114 Seal- End 043734313 4 116 Stop- Damper 047110101 2 117 End Plug 111062001 1 118 End Plug 111062201 1 119 End Plug 057783404 1 120 Blade- Damper 047793307 4 122 Actuator ACT12 24V 113145001 1 124 Coupling- Shaft 111045001 1 125 End Plug 041003508 3 126 End Plug 041003509 2 127 Bushing- Linkage 046098300 8 128 Bushing- Damper Blade 043730400 5 129 Shaft- Drive 043734000 4 130 Lock Collar .50 049115902 1 133 Gasket- Vinyl 17" L 044193134 4 134 Gasket- Vinyl 17" L 055940217 2

130

128

114

134

124

120116

126 114133 118

Page 55: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 55

Section A2- Outdoor/Return Air w/ Heat Recovery SectionHeat Recovery— Enthalpy— Wheel Detail (Ref. #160)

Wheel, Motor, Drive Components, Seals

Outdoor Air Out (Supply)

Exhaust Air In (Return) 163161

164

162

165

Ref. Part Part Qty. No. Description Number Wheel Assy.- Complete 1 208/230/460V 060019601 Wheel Assy.- Complete 1 575V 060019602 Wheel 2 Segmented 300043255 1 161 Motor 208/230/460V 300043698 1 Motor 575V 300043256 1 162 Sheave 111048001 1 163 Bearing 300043248 1 164 Shaft 1" x 7.7" 300043254 1 165 Belt 300043251 1 N/S Inner/Outer Seal 300043252 4N/S= Not Shown on diagram.1 Includes Motor, Shaft, Belt etc.2 If a replacement Wheel is required, it is suggested that this part number be used. This segmented

Wheel ships disassembled which allows for easier shipping and installation.

Page 56: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 56

Section A2- Outdoor/Return Air w/ Heat Recovery SectionVFD60 Frost Protection Inverter (Code 24= F)

100% OA Hi Flow (Code 20= 2E)

3

Mid- Section Junction Box

Mid- Section Upright

Base Rail

100% OA Low Flow (Code 20= 1E)

3

Base Rail

Rear SupportCross MemberRear Filter

Rack Up-right

Economizer (Code 20= 3E)

3

RA Damper

Assy

Rear Filter Rack

Voltage Ref. Sch. Part Part No. Sym. Description Number 3 VFD60 Inverter 193475806 2 1 1 VFD60 Inverter 193475822 2 1 VFD60 Inverter 349956738 2 1

208V

230V

460V

575V

208V

230V

460V

575V

Mid 2012 & Later

Mid 2012 & Earlier 1

1 In Mid 2012 the Unit Model Nomenclature was changed to code the different Inverter brands offered. Before this date ATV21 OR ATV212 drives (see note below) were standard.

2 In 2010 the original ATV21 Inverters were replaced with ATV212 Inverters as listed above. These inverters are drop in replacements with the exception of the Remote Keypad and Communication Cards. If a Communication card OR Remote Keypad is required, contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. Note that since the original ATV21 drives are obsolete and unavailable, when at zero stock, repair parts are also not available. If an obsolete ATV21 part fails, the entire drive must be replaced.

Voltage Ref. Sch. Part Part No. Sym. Description Number 3 Code 23= **A** 3

VFD60 Inverter 4 099488103 1 1 Inverter 4 099488004 1 Inverter 4 112046026 1 Code 23= **B** 3

VFD60 Inverter 4 193552245 1 1 Inverter 4 193552295 1 Inverter 4 193552326 1 Code 23= **Q** 3

VFD60 Inverter 193475806 1 1 Inverter 193475822 1 Inverter 193456302 13 For the fusing for VFD60, refer to the "Energy Recovery Wheel Contactors, MMPs, & Fusing 04/13 & Later" page in

Section N. 4 The replacement VFD Keypad is p/n 300040924.

Page 57: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 57

Section A2- Outdoor/Return Air w/ Heat Recovery SectionSection Mounted ControlsOAE, RAE, RAT, EAT, LAT

184

Ref. Part Part Qty. No. Description Number 184 Support- RAT 111077601 1 200 Sensor- RAT 193414602 1

RAT- Outdoor Air Temperature Sensor

RA Open-

ing

200

Deck Panel

Return Fan

500 422

Ref. Part Part Qty. No. Description Number 422 Support- EAT 111078001 1 500 Sensor- EAT 193414602 1

EAT- Entering Air Temperature Sensor

600 582

Ref. Part Part Qty. No. Description Number 582 Support- LAT 111075901 1 600 Sensor- LAT 193414602 1

LAT- Leaving Air Temperature Sensor

Ref. Part Part Qty. No. Description Number 40 Mount- OAE Enthalpy 1 1 41 Control- OAE 1 1

40OAE- Mechanical Enthalpy (Code 17= Y*)

41

Ref. Part Part Qty. No. Description Number 40 Mount- OAE Enthalpy 2 1 41 Control- OAE 2 1 42 Mount- RAE Enthalpy 2 1 48 Control- RAE 2 1

OAE & RAE Differential Enthalpy (Code 17= C*)

48

42

Economizer Damper

Bottom ReturnShown

Code 19= BY, BE

Bottom ReturnShown

Code 19= BY, BE

1 The original control is obsolete & no longer available. For the OAE Control use p/n 113103601 & Mount 910146257. Minor field modifications are required for proper installation & operation when changing to the newer design.

2 BOTH original controls are obsolete & no longer available. For the OAE Control use 113103601 & Mount 910146257. For the RAE Control use 113103701 & Mount 055732301. Note that when changing out EITHER ONE of the older style controls BOTH CONTROLS MUST BE CHANGED TO THE NEWER VERSION. When upgrading to the new style controls, field modifications, including the installation of Relay 349934722 (OAER), are required for proper installation & operation.

Economizer Damper

40

41

Page 58: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 58

Section A2- Outdoor/Return Air w/ Heat Recovery SectionSection Mounted Controls

SD2, HUM1, LT11, S11, REC11

LT11- Return Fan Light/S11- Return Fan Light Switch/REC11- Return Fan Light ReceptacleCode 49= E, F

84

85

88 89

230

227

Ref. Part Part Qty. No. Description Number 227 Support- SD2 111079701 1 230 Smoke Detector- SD2 098873101 1

SD2- Return Air Smoke Detector (Code 16= 1, 3)Heat Wheel

RA Opening

Ref. Part Part Qty. No. Description Number 596 Support- HUM1 12/16 & Earlier 111078101 1 1/17 & Later 910194091 1 597 Humidistat- HUM1 12/16 & Earlier 067295001 1 1 1/17 & Later 910190890 1 1

HUM1- Humidistat (units with frost protection)Code 24= F

596597

Return Air Opening RAT

Deck Panel

1 This is the duct mounted Humidistat. If a unit has a wall mounted Humidistat use p/n 067294901.

Ref. Part Part Qty. No. Description Number 84 Light Fixture 6/13 & Earlier 042229500 1 Light Fixture 7/13 & Later 910145007 1 85 Bulb- LT11 065492402 1 88 Light Switch- S11 065492201 1 89 Receptacle- REC11 030187000 1

Page 59: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 59

Section B- DrawThru Filter/Blank/Empty SectionNotes➩

Primary Codes that pertain: 25, 33 (Mid 2012 & Later), 50 (Mid 2012 & Later)Additional Codes that pertain: 06, 19, 20

Code 25 determines the section's characteristics. If the first digit of Code 25= A, D, E the Filters are in an angular rack, and if the first digit = F, G, H the Filters are in a flat rack. If the second digit = B there are 30% eff. throwaway filters and if C there are 30% eff. throwaway filters with Antimicrobial Intersept. If the second digit = D there are 65% eff. filters, if E there are 95% eff. filters, and if G there are 95% eff. filters with Antimicrobial Intersept. If the second digit = Y there is no filter media specified. If Code 25 = BY, CY there is a Blank/Empty Section. Code 25= D*, E*, G*, H*, T*, V* OR Code 50 (Mid 2012 & Later)= L, H indicates the presence of an Air Blender.

Code 33 (Mid 2012 & Later) indicates the presence of a Magnehelic/Differential Filter gauge. Even though the gauge may be located in several different places in the unit, the p/n is listed in this section for convenience.

Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the DrawThru Filter/Blank/Empty Section, contact Daikin Applied with model and serial number information to ensure correct liners, insulation and hardware are ordered. For standard Access Door Latching Assemblies, see Section H.

Codes 19 and 20 determine the Return Air section which has an effect on the final assembly panels.

Section B- DrawThru Filter/Blank/Empty SectionSection Mounted Controls

PC5- Clogged Filter Control

65

34

Ref. Part Code 25 OR Part Qty. No. Description Code 50 (Mid 2012 & Later) Number 34 Air Blender Low CFM GD, GE, DB, DC, L 205139536 1 High CFM HD, HE, EB, EC, H 205139542 1

Section B- DrawThru Filter/Blank/Empty SectionAir Blender

(Code 25= DB, DC, GD, GE, HD, HE, EB, EC OR Code 50 [Mid 2012 & Later] L, H)

Ref. Part Part Qty. No. Description Number 65 Pressure Ctl- PC5 065493801 1

Page 60: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 60

Section B- DrawThru Filter SectionFilter Section Diagrams and Components

Typical Angular Filter Section Shown

Code 25= A*

Magnehelic/Differential Pressure GaugeCode 33= A****, B****, C**** (Mid 2012 & Later)3396 Ref. Part Part No. Description Number 3396 Differential Press. Gauge, 0- 3” WC 098873203

Ref. Part Code Part Qty. No. Description 25= Number Angular Filter Section (Code 25= A*) N/S Filter 30% Pleated, 16 x 25 x 2" MERV 8 *B 111046306 10 30% Pleated, 16 x 25 x 2" w/ Intersept MERV 8 *C 031298002 10 85% Pleated, 16 x 25 x 2" MERV 13 *H 910102150 10 N/S Filter 30% Pleated, 16 x 20 x 2 MERV 8 *B 111046305 10 30% Disposable, 16 x 20 x 2" w/ Intersept MERV 8 *C 111046505 10 85% Pleated, 16 x 20 x 2 MERV 13 *H 910102152 10 N/S Media Filler Piece ALL 011484101 5 Flat Filter Section (Code 25= F*) N/S Filter 65% Cartridge, 24 x 24 x 12" MERV 11 *D 065810704 4 95% Cartridge, 24 x 24 x 12" MERV 14 *E 065810702 4 95% Cartridge, 24 x 24 x 12" w/ Intersept MERV 14 *G 066302252 4 N/S Filter 65% Cartridge, 12 x 24 x 12" MERV 11 *D 065810703 4 95% Cartridge, 12 x 24 x 12" MERV 14 *E 065810701 4 95% Cartridge, 12 x 24 x 12" w/ Intersept MERV 14 *G 066302253 4 N/S Pre Filter, 30% 111046101 4 N/S Pre Filter, 30% 111046103 4 N/S Gasket- 1/4" x 1 1/2" 026172804 2 N/S Gasket- Dbl. 056001104 4

Filter Section Parts

Page 61: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 61

Section C- DrawThru Blank/Empty SectionOR Separate Inverter Section

Notes

Primary Codes that pertain: 26, 14, 15Additional Codes that pertain: 06

Code 26 determines if a section is installed and if so, the size of the section. If Code 26= S the section is 40" (this code is also necessary if the inverters are installed in this section), and if Code 26= T the section is 52". If Code 26= Y, there is no section.

Codes 14 & 15 determine if the unit has inverter(s) and if so where they are installed. If Code 14= 1, 2, 4 AND Code 26= S (Mid 2013 & Earlier), there is a separate Inverter Section. If Code 14= 3, 5, 6, 7, 8, 9, the inverter(s) are installed in the Supply Air Section. If Code 14= Y, there are no inverters. If Code 15= F, the unit is set up for a field supplied inverter. If Code 15= F, contact Daikin Applied with the Inverter Vendor and vendor part number to see if a replacement can be supplied. All components pertaining to the inverter(s) are listed in the Supply Air Section (Section F).

Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the DrawThru Blank/Empty/Inverter Section, contact Daikin Applied with model and serial number information to ensure correct liners, insulation and hardware are ordered. For standard Access Door Latching Assemblies, see Section H.

Page 62: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 62

Section D- DrawThru Cooling SectionNotes

Primary Codes that pertain: 27, 28Additional Codes that pertain: 06

NOTE: Section D applies only to unit sizes 035- 042D. The DrawThru Evaporator Cooling Coil and associated components for unit sizes 015- 031D are located in Section F (Supply Air Section).

Code 27 determines if there is a Section D. If Code 27= YYYY, there is no section. If the first three digits of Code 27= CYY this is a cooling unit with a 22" section between the Filter and Supply Fan Sections. If the first three digits of Code 27= DYY then the section contains only a Drain Pan. If the first three digits of Code 27= GYY then the unit is cooling with Hot Gas Reheat. If the fourth digit of Code 27= S, the Drain Pan is stainless steel. P in the fourth position indicates that the pan is galvanized steel. If the fourth digit is L, the Drain Pan is wider than standard and made from stainless steel. If the fourth digit of Code 27= T, then the unit is equipped with a wider than standard painted galvanized steel Drain Pan. If the fourth digit of Code 27= L, T then the first three digits of Code 27 must equal DYY.

Code 28 determines Cooling Coil characteristics.

Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the DrawThru Cooling Section, contact Daikin Applied with model and serial number information to ensure correct liners, insulation and hardware are ordered. For standard Access Door Latching Assemblies, see Section H.

Page 63: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 63

Unit Base

Section D- DrawThru Cooling SectionEvaporator Coil Drain Pans and Gaskets

Code 27= CYYY, CYYP, CYYS- 22" Section- Unit Sizes 035- 042D 1

3

39

13

14

Drain PansCode 27= DYYY, DYYS- 40" Section- Unit Sizes 035- 042D

Diagram and Components

Ref. Part Drain Pan Material Code 27= Qty. No. Description DYYY- Galvanized DYYS- Stainless 103 Drain Pan 056280471 056280421 1

103Unit Base

1 For Drain Pans and components when Code 27= GYY* and/or Code 27 Digit 4= L or T, use the Distributor Tools BOM Search function on the Daikin Parts website or contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified.

Ref. Part Code 27= Part Qty. No. Description Number 3 Coil- refer to the following page 13 Drain Pan- Auxiliary 4/11 & Earlier CYYY, CYYP, CYYS 058586803 1 5/11 & Later CYYP, CYYS 404042001 1 14 Drain Pan- Main Galvanized CYYY 056280472 1 Stainless Steel CYYS 056280422 1 39 Gasket 049263200 5 ft.

Page 64: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 64

Section D- DrawThru Cooling SectionEvaporator Coils 1

Unit Sizes 035- 042D

Typical CoilDescription

4Z 08 3 D

Coil Model

Fins-per-inch08= 8 FPI10= 10 FPI12= 12 FPI14= 14 FPI

Rows3= 3 Row Coil4= 4 Row Coil5= 5 Row Coil6= 6 Row Coil

Fin StockC= Hi-F Copper Fin (stainless casing)D= Lanced Aluminum Fin (galv. casing)

1 Evaporator Coils are serial number specific. Contact Daikin Applied with complete model and serial number information in order to ensure that the correct coil is identified.

Page 65: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 65

Section E- DrawThru Blank/Empty SectionNotes

Primary Codes that pertain: 30Additional Codes that pertain: 06

If Code 30= BBBBBB, CCCCCC there is a Blank/Empty 40" Section. If Code 30= AAAAAA there is a Blank/Empty 22" Section. If Code 30= YYYYYY, there is no section.

Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the DrawThru Blank/Empty Section, contact Daikin Applied with model and serial number information to ensure correct liners, insulation and hardware are ordered. For standard Access Door Latching Assemblies, see Section H.

LT17- DT/Blank Section Light/S17- DT/Blank Section Light Switch/REC17- DT/Blank Section Receptacle284 285

288 289

Section Mounted ControlsLT17, REC17, S17- Section Mounted Light

Ref. Part Part Number Qty. No. Description N/S Sleeve Bearing 047138507 2 N/S Door Catch 055502602 1 N/S Gasket 048165901 1

Cabinet Door Gasketing and Hardware

N/S= Not Shown on diagram.1 This part is ordered by the foot. Order as many feet as needed.

Ref. Part Part Qty. No. Description Number 284 Light Fixture 6/13 & Earlier 042229500 1 Light Fixture 7/13 & Later 910145007 1 285 Bulb- LT17 065492402 1 288 Light Switch- S17 065492201 1 289 Receptacle- REC17 030187000 1

Page 66: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 66

Section F- Supply Air SectionNotes

Primary Codes that pertain: 31, 32, 33 (Mid 2012 & Earlier), 59 (Mid 2012 & Later), 14, 15, 49, (all unit sizes); 27, 28 (015- 031D only)Additional Codes that pertain: 04, 06, 16, 17, 23 (Mid 2012 & Later), 33 (Mid 2012 & Later), 34

NOTE: The DrawThru Evaporator Cooling Section for unit sizes 015- 031D is located in Section F. Components for the DrawThru Evaporator Section for unit sizes 035- 042D are listed in Section D.

Code 31 determines the Supply Fan size and type, Code 32 determines the Supply Fan Motor horsepower and type, and Code 33 (Mid 2012 & Earlier) OR 59 (Mid 2012 & Later) determine the drive selection. Supply Air Fan Section parts, Fans, and Motors are listed in this section. Drive components (Fan Sheave, Motor Sheave, V-belt[s], and Sheave Bushing[s]- if required) are NOT listed as they are unique to the unit. If a drive component is required you may use the number from the part and cross reference it in the Daikin Applied Parts catalog, The Daikin Parts E-Commerce site, or contact Daikin Applied with model and serial number information.

Codes 14 and 15 determine if the unit has inverter(s) and if so where they are installed. If Code 14= 3, 5, 6, 7, 8, 9, the inverter(s) are installed in the Supply Air Section. If Code 14= 1, 2, 4 AND/OR Code 26= S, there is a separate Inverter Section. If Code 14= Y, there are no inverters. Code 15 specifies the Inverter Vendor. If Code 15= F, the unit is set up for a field supplied inverter. If Code 15= F, contact Daikin Applied with the Inverter Vendor and vendor part number to see if a replacement can be supplied.

Code 49 determines if the Supply Air Fan Section has a Belt Guard (Code 49= A, D), a Fan Section Light (Code 49= B, E), or both (Code 49= C, F).

Codes 27 and 28 determine the DrawThru Evaporator Section, and pertain to the coil and Drain Pan installed in section F for unit sizes 016- 031D. If the first three digits of Code 27= CYY this is a cooling unit with the coil located in the Supply Fan Section. If the first three digits of Code 27= DYY then the section contains only a Drain Pan. If the first three digits of Code 27= GYY then the unit is cooling with Hot Gas Reheat. If the fourth digit of Code 27= S, the Drain Pan is stainless steel; P, Y in the fourth position indicates that the Drain Pan is galvanized steel. If the fourth digit is L, the Drain Pan is wider than standard and made from stainless steel. If the fourth digit of Code 27= T, then the unit is equipped with a wider than standard painted galvanized steel Drain Pan. If the fourth digit of Code 27= L, T then the first three digits of Code 27 must equal DYY.

Code 04 and Code 34 determine the heat type, which can affect the final assembly part numbers, as well as the section installed controls.

Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the Supply Air Section, contact Daikin Applied with model and serial number information to ensure correct liners, insulation and hardware are ordered. For standard Access Door Latching Assemblies, see Section H.

Code 16 determines if a Smoke Detector is located in the Supply Air Cabinet. If Code 16= 2, 3, a Smoke Detector (SD1) is present.

Code 17 determines the type of Enthalpy and Miscellaneous Auxiliary Controls included. The second digit of Code 17 lists the inclusion of Freezstats, Line Reactors, Phase Failure, and Ground Fault protection.

Code 23 (Mid 2012 & Later) indicates the presence of Plenum/Vestibule Lights, UV lights, misc. inverters, a 115V Service Outlet, and/or Intelligent Equipment.

Code 33 (Mid 2012 & Later) indicates the presence of a Magnehelic/Differential Filter Gauge and/or Ebtron Flow Controls, Refer to Section B (DrawThru Filter Section) for the Gauge part number and description. Note if Ebtron Flow Controls are present (Code 23= ****S, ****G) contact Daikin Applied with model and serial number information so that the correct control can be identified.

Page 67: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 67

Sizes 015, 018,020

Section F- Supply Air SectionDrawThru Evaporator Coil Drain Pans

Unit Sizes 015- 031DCode 27= CYYY, CYYP, CYYS- 40" Section 1

Unit Base

3

39

13

14

Drain PansUnit Sizes 015- 031D

Code 27= DYYY, DYYS- 40" Section

Ref. Part Drain Pan Material Code 27= Qty. No. Description DYYY- Galvanized DYYS- Stainless 103 Drain Pan 056280471 056280421 1

103Unit Base

Sizes 025,030,031

Unit Base

3

39

13

14

1 For Drain Pans and components when Code 27= GYY* AND/OR Code 27 Digit 4= L, T, use the Distributor Tools BOM Search function on the Daikin Parts website or contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified.

Ref. Part Code 27= Part Qty. No. Description Number 3 Coil- refer to the following page 13 Drain Pan- Auxiliary 4/11 & Earlier CYYY, CYYP, CYYS 058586803 1 5/11 & Later CYYP, CYYS 404042001 1 14 Drain Pan- Main Galvanized CYYY 056280472 1 Stainless Steel CYYS 056280422 1 39 Gasket 049263200 5 ft.

Page 68: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 68

Section F- Supply Air SectionEvaporator Coils 1

Unit Sizes 015- 031D

Typical CoilDescription

4Z 08 3 D

Coil Model

Fins-per-inch08= 8 FPI10= 10 FPI12= 12 FPI14= 14 FPI

Rows3= 3 Row Coil4= 4 Row Coil5= 5 Row Coil6= 6 Row Coil

Fin StockC= Hi-F Copper Fin (stainless casing)D= Lanced Aluminum Fin (galv. casing)

1 Evaporator Coils are serial number specific. Contact Daikin Applied with complete model and serial number information in order to ensure that the correct coil is identified.

Page 69: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 69

Ref. Part Fan Size: Code 31= Qty. No. Description 06F* 15F* 2 Wheel Assembly 040803700 033135100 2 5 Motor Mount Bolt 033453500 033453500 2 6 Blower Frame 058402161 058402162 1 11 Shaft 041001401 033454601 1 12 Filler Piece 041001200 033453400 1 13 Tubing 021136738 021136738 1 14 Tubing 021136774 021136774 1 15 Motor Base 058402191 058402191 1 18 Tube Clamp 001324600 001324600 3 20 Shim 1 2 21 Shaft Key 023221309 023221409 2 22 Shaft Key 023221303 023221410 1 23 Coupling 027674000 027674000 2 24 Coupling- Reducer 027674100 027674100 2 25 Bearing- Pillow Block 020648662 5 020648651 5 3 N/S Belt Guard Assy 3 058402096 058402096 1

Section F- Supply Air SectionFan Assembly

15" X 6" AND 15" X 15" Forward Curved Fans Code 31= 06F*, 15F*Unit Sizes 015- 031D

Motor 4

N/S= Not Shown on diagram.1 Any of the following shims may be used: 091532101 (.022); 091532001 (.031);

091531901 (.046); 091531801 (.046); 026637400 (.058).2 Any of the following shims may be used: 025639900 (.058); 091531301 (.046);

091531401 (.046); 091531501 (.031); 091531601 (.022).3 Code 49= A, C, D, F.4 Motors are listed after the fan mounting section.5 Some units may have had setscrew locking style bearings installed. This concentric

locking collar style bearing is the recommended replacement.

5

15

23

14

25

12

21

624

2

22

25

11

1813

18

Page 70: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 70

Ref. Part Part Qty. No. Description Number 2 Blower Housing 058402164 1 3 Wheel: DWAF 023392415 1 5 Motor Mount 033453500 2 11 Shaft 058490101 1 15 Motor Shelf 058402194 1 21 Shaft Key 023221507 1 22 Shaft Key 023221505 1 25 Bearing 020648653 3 2 N/S Grille- Belt Guard 2 058573101 1

Section F- Supply Air SectionFan Assembly

20" Airfoil FansCode 31= 20A1, 20A2, 20A3

Unit Sizes 015- 031D

N/S= Not Shown on diagram.1 Motors are listed after the fan mounting section.2 Code 49= A, C, D, F.3 Some units may have had setscrew locking style bearings

installed. This concentric locking collar style bearing is the recommended replacement.

Motor 1

15

3

25

2

5

1121

22

5

Page 71: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 71

Section F- Supply Air SectionFan Assembly

24" Forward Curved LP Fans Code 31= 24F1, 24F2, 24F3

Unit Sizes 035- 042D

Ref. Part Part Qty. No. Description Number 102 Housing 030030201 1 103 Base 058402169 1 104 Mount- Bearing 058402166 2 105 Wheel 024061015 1 106 Screw- Adjusting 055528202 2 111 Shaft 030631201 1 112 Cut Off Plate 030030101 1 115 Mount- Motor 058402171 1 116 Angle- Mount 055514201 1 117 Angle- Mount 104400801 2 120 Shim- Lower 021494200 1 121 Shaft Key 023221409 1 122 Shaft Key 023221415 1 125 Bearing 020648651 3 2 N/S Belt Guard Assy 2 058402099 1

Motor 1

112

111

117

105

120 102

115

104

103106 104

125

116

120

122

121

N/S= Not Shown on diagram.1 Motors are listed after the fan mounting section.2 Code 49= A, C, D, F.3 Some units may have had setscrew locking style bearings

installed. This concentric locking collar style bearing is the recommended replacement.

Page 72: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 72

Section F- Supply Air SectionFan Assembly

24" Airfoil FansCode 31= 24A1, 24A2, 24A3

Unit Sizes 035- 042D

Ref. Part Part Qty. No. Description Number 2 Blower Housing 058402167 1 3 Wheel: SISW C.W. 110945604 1 4 Wheel: SISW C.C.W. 110945704 1 11 Shaft 034276201 1 15 Mount- Motor 058402171 1 16 Angle- Mount 055514201 1 17 Angle- Motor Mount 104400801 2 21 Key 023221508 1 22 Key 023221513 1 25 Bearing 020648653 3 2 N/S Belt Guard Assy 2 058402099 1

15

17

16

25

2

421

Wheels- View looking TOWARDS Discharge

Opening

11 21

22

Motor 1

3

N/S= Not Shown on diagram.1 Motors are listed after the fan mounting section.2 Code 49= A, C, D, F.3 Some units may have had setscrew locking style bearings

installed. This concentric locking collar style bearing is the recommended replacement.

Page 73: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 73

Section F- Supply Air SectionSupply Air Fan Mounting- 15" x 6" Forward Curved Fan

Code 31= 06F1, 06F2, 06F3

Spring Mounting Code 31= 06F2 OR Seismic Mount Code 31= 06F3

81

Ref. Part Part Qty.2

No. Description Number 21 Spring Mount- Standard 251783201 1 Spring Mount- Seismic 251783301 1 3

31 Spring Isolator- Position 3 Motor H.P.= 1 thru 5 251784501 1 Motor H.P.= 7.5 thru 15 251784601 1 Motor H.P.= 20 251784701 1 32 Spring Isolator- Position 4 Motor H.P.= 1 thru 15 251784501 1 Motor H.P.= 20 251784601 1 33 Spring Isolator- Position 2 Motor H.P.= 1 thru 5 251784601 1 Motor H.P.= 7.5 thru 10 251784701 1 Motor H.P.= 15 thru 20 251784801 1 Motor H.P.= 10 251784801 1 34 Spring Isolator- Position 1 Motor H.P.= 1 thru 7.5 251784601 1 Motor H.P.= 10 thru 20 251784701 1 81 Clinch Nut- Standard 059992201 3 Clinch Nut- Seismic 111056301 5 3

88 Nut 040500002 1 89 Screw- Standard 112047201 3 Screw- Seismic 112047201 5 3

33 Pos. 2 31

34 32

Top View Air

Flow

Seismic strap used only when Code 31= 06F3.

Pos. 3

Pos. 4Pos. 1

21

31 32

33 34

88

89

2 Drawing is common to all four corners. Quantities listed are for ONE mount.3 This part is used only when Code 31= 06F3.

Rubber-In-Shear (RIS) Mount Code 31= 06F1 Ref. Part Part Qty.1

No. Description Number 21 Support Mount 055512101 1 31 Isolator R- 3 Black 021639704 1 81 Clinch Nut 059992201 2 89 Screw 112047201 2 91 Nut 032333305 3 92 Screw 040499501 2

31

21

92

91

1 Drawing is common to all four corners. Quantities listed are for ONE mount.91

89

81

Page 74: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 74

Section F- Supply Air SectionSupply Air Fan Mounting- 15" X 15" Forward Curved Fan

Code 31= 15F1, 15F2, 15F3

Spring Mounting Code 31= 15F2 OR Seismic Mount Code 31= 15F3 Ref. Part Part Qty.2

No. Description Number 21 Spring Mount- Standard 251783201 1 Spring Mount- Seismic 251783301 1 3

31 Spring Isolator- Position 3 Motor H.P.= 1 thru 5 251784601 1 Motor H.P.= 7.5 thru 15 251784701 1 Motor H.P.= 20 251784801 1 32 Spring Isolator- Position 4 Motor H.P.= All 251784601 1 33 Spring Isolator- Position 2 Motor H.P.= 1 thru 3 251784601 1 Motor H.P.= 5 thru 10 251784701 1 Motor H.P.= 15 thru 20 251784801 1 34 Spring Isolator- Position 1 Motor H.P.= 1 thru 7.5 251784601 1 Motor H.P.= 10 thru 20 251784701 1 81 Clinch Nut- Standard 059992201 3 Clinch Nut- Seismic 111056301 5 3

88 Nut 040500002 1 89 Screw- Standard 112047201 3 Screw- Seismic 112047201 5 3

81

Seismic strap used only when Code 31= 15F3.

33 Pos. 2 31

34 32

Top View Air

Flow

Pos. 3

Pos. 4Pos. 1

21

31 32

33 34

88

89

Rubber-In-Shear (RIS) Mount Code 31= 15F1 Ref. Part Part Qty.1

No. Description Number 21 Support Mount 055512101 1 31 Isolator R- 3 Black 021639704 1 81 Clinch Nut 059992201 2 89 Screw 112047201 2 91 Nut 032333305 3 92 Screw 040499501 21 Drawing is common to all four corners. Quantities listed are for ONE mount.

31

21

92

91

91

89

81

2 Drawing is common to all four corners. Quantities listed are for ONE mount.3 This part is used only when Code 31= 15F3.

Page 75: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 75

Section F- Supply Air SectionSupply Air Fan Mounting- 20" Airfoil Fan

Code 31= 20A1, 20A2, 20A3

Spring Mounting Code 31= 20A2 OR Seismic Mount Code 31= 20A3 Ref. Part Part Qty.2

No. Description Number 21 Spring Mount- Standard 251783201 1 Spring Mount- Seismic 251783301 1 3

31 Spring Isolator- Position 3 Motor H.P.= 1 thru 2 251784601 1 Motor H.P.= 3 thru 15 251784701 1 Motor H.P.= 20 251784801 1 32 Spring Isolator- Position 4 Motor H.P.= 1 thru 5 251784601 1 Motor H.P.= 7.5 thru 20 251784701 1 31 Spring Isolator- Position 2 Motor H.P.= 1 thru 2 251784501 1 Motor H.P.= 3 thru 5 251784601 1 Motor H.P.= 7.5 thru 15 251784701 1 Motor H.P.= 20 251784801 1 34 Spring Isolator- Position 1 Motor H.P.= 1 thru 3 251784501 1 Motor H.P.= 5 thru 10 251784601 1 Motor H.P.= 15 thru 20 251784701 1 81 Nut Spring Mount- Standard 059992201 3 Spring Mount- Seismic 111056301 5 3

88 Nut 040500002 1 89 Screw Spring Mount- Standard 112047201 3 Spring Mount- Seismic 112047201 5 3

31

21

92

91

91

89

81

Rubber-In-Shear (RIS) Mount Code 31= 20A1 Ref. Part Part Qty.1

No. Description Number 21 Support Mount 055512101 1 31 Spring Isolator- Position 3 Motor H.P.= All 021639704 1 62 Spring Isolator- Position 4 Motor H.P.= All 021639704 1 63 Spring Isolator- Position 2 Motor H.P.= 1 thru 7.5 021639704 1 Motor H.P.= 10 thru 20 021639701 1 34 Spring Isolator- Position 1 Motor H.P.= All 021639704 1 81 Clinch Nut 059992201 2 89 Screw 112047201 2 91 Nut 032333305 3 92 Screw 040499501 21 Drawing is common to all four corners. Quantities listed are for ONE mount.

81

Seismic strap used only when Code 31= 20A3.

33 Pos. 2 31

34 32

Top View Air

Flow

Pos. 3

Pos. 4Pos. 1

21

31 32

33 34

88

89

2 Drawing is common to all four corners. Quantities listed are for ONE mount.3 This part is used only when Code 31= 20A3.

Page 76: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 76

Section F- Supply Air SectionSupply Air Fan Mounting- 24" Airfoil Fan

Code 31= 24A1, 24A2, 24A3

Ref. Part Part Qty.1

No. Description Number 21 Support Mount 055512101 1 31 Isolator- RP- 3 Red 021639701 1 81 Clinch Nut 059992201 2 89 Screw 112047201 2 91 Nut 032333305 3 92 Screw 040499501 2

Rubber-In-Shear (RIS) Mount Code 31= 24A1

Spring Mounting Code 31= 24A2 OR Seismic Mount Code 31= 24A3 Ref. Part Part Qty.2

No. Description Number 21 Mount- Spring Spring Mount- Standard 251783201 1 Spring Mount- Seismic 251783301 1 3

31 Spring Isolator- Position 3 Motor H.P.= 1 thru 10 251784701 1 Motor H.P.= 15 thru 25 251784801 1 32 Spring Isolator- Position 4 Motor H.P.= All 251784701 1 33 Spring Isolator- Position 2 Motor H.P.= 1 thru 3 251784601 1 Motor H.P.= 5 thru 10 251784701 1 Motor H.P.= 15 thru 20 251784801 1 Motor H.P.= 25 251784901 1 34 Spring Isolator- Position 1 Motor H.P.= 1 thru 15 251784701 1 Motor H.P.= 20 thru 25 251784801 1 81 Nut Spring Mount- Standard 059992201 3 Spring Mount- Seismic 111056301 5 3

88 Nut 040500002 1 89 Screw Spring Mount- Standard 112047201 3 Spring Mount- Seismic 112047201 5 3

1 Drawing is common to all four corners. Quantities listed are for ONE mount.

31

21

92

91

91

89

81

81

Seismic strap used only when Code 31= 24A3.

33 Pos. 2 31

34 32

Top View Air

Flow

Pos. 3

Pos. 4Pos. 1

21

31 32

33 34

88

89

2 Drawing is common to all four corners. Quantities listed are for ONE mount.3 This part is used only when Code 31= 24A3.

Page 77: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 77

Rubber-In-Shear (RIS) Code 31= 24F1

Spring Mounting Code 31= 24F2 OR Seismic Mount Code 31= 24F3 Ref. Part Part Qty.2

No. Description Number 21 Mount- Spring Spring Mount- Standard 251783201 1 Seismic Mount- Seismic 251783301 1 3

31 Spring Isolator- Position 3 Motor H.P.= 1 thru 10 251784701 1 Motor H.P.= 15 thru 25 251784801 1 32 Spring Isolator- Position 4 Motor H.P.= All 251784701 1 33 Spring Isolator- Position 2 Motor H.P.= 1 thru 3 251784601 1 Motor H.P.= 5 thru 10 251784701 1 Motor H.P.= 15 thru 20 251784801 1 Motor H.P.= 25 251784901 1 34 Spring Isolator- Position 1 Motor H.P.= 1 thru 15 251784701 1 Motor H.P.= 20 thru 25 251784801 1 81 Nut Spring Mount- Standard 059992201 3 Seismic Mount- Seismic 111056301 5 3

88 Nut 040500002 1 89 Screw Spring Mount- Standard 112047201 3 Seismic Mount- Seismic 112047201 5 3

Section F- Supply Air SectionSupply Air Fan Mounting- 24" Forward Curved Fan

Code 31= 24F1, 24F2, 24F3

Ref. Part Part Qty.1

No. Description Number 21 Support Mount 055512101 1 31 Isolator RP- 3 Red 021639701 1 81 Clinch Nut 059992201 2 89 Screw 112047201 2 91 Nut 032333305 3 92 Screw 040499501 21 Drawing is common to all four corners. Quantities listed are for ONE mount.

31

21

92

91

91

89

81

81

Seismic strap used only when Code 31= 24F3.

33 Pos. 2 31

34 32

Top View Air

Flow

Pos. 3

Pos. 4Pos. 1

21

31 32

33 34

88

89

2 Drawing is common to all four corners. Quantities listed are for ONE mount.3 This part is used only when Code 31= 24F3.

Page 78: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 78

H.P. Motor H.P. Unit ODP HiEff ODP PrEff TEFC HiEff TEFC PrEff Code 32= Voltage C32= *EY C32= *JY C32= *HY C32= *KY C09= 12 1 E*Y 208/60/3 039447400 205167600 049100100 004735000 1.5 F*Y 208/60/3 039442200 205167500 049100200 046513100 2 G*Y 208/60/3 039895700 046515500 049100300 073321000 3 H*Y 208/60/3 039447500 065817100 047358100 065819400 5 J*Y 208/60/3 039447600 065817200 049186800 065819500 7.5 K*Y 208/60/3 037530300 065817300 047665900 065819600 10 L*Y 208/60/3 038999000 065817400 047666100 065819700 15 M*Y 208/60/3 039896200 065817500 049186900 065819800 20 N*Y 208/60/3 039895800 065817600 049187000 065819900 25 P*Y 208/60/3 039448900 065817700 049187100 065820000 C09= 29 1 E*Y 230/60/3 039446200 205162800 040161000 046513000 1.5 F*Y 230/60/3 039442300 046511100 040161100 046513100 2 G*Y 230/60/3 039446300 205163500 047446000 073321000 3 H*Y 230/60/3 039442400 065818100 049262300 065820100 5 J*Y 230/60/3 039442500 065818200 040161200 065820200 7.5 K*Y 230/60/3 039448700 065818300 049100500 065820300 10 L*Y 230/60/3 039446500 065818400 044691100 065820400 15 M*Y 230/60/3 039446600 065818500 038689700 065820500 20 N*Y 230/60/3 039448800 065818600 040161300 065820600 25 P*Y 230/60/3 039896100 065818700 040161400 065820700 C09= 27 1 E*Y 460/60/3 039446200 205162800 040161000 046513000 1.5 F*Y 460/60/3 039442300 046511100 040161100 046513100 2 G*Y 460/60/3 039446300 205163500 047446000 073321000 3 H*Y 460/60/3 039442400 065818100 049262300 065820100 5 J*Y 460/60/3 039442500 065818200 040161200 065820200 7.5 K*Y 460/60/3 039448700 065818300 049100500 065820300 10 L*Y 460/60/3 039446500 065818400 044691100 065820400 15 M*Y 460/60/3 039446600 065818500 038689700 065820500 20 N*Y 460/60/3 039448800 065818600 040161300 065820600 25 P*Y 460/60/3 039896100 065818700 040161400 065820700 C09= 37 1 E*Y 575/60/3 049180800 206500900 049188000 206505600 1.5 F*Y 575/60/3 049180900 206501600 049188100 205167800 2 G*Y 575/60/3 049181000 205168300 049188200 046514400 3 H*Y 575/60/3 046741600 046511700 049188300 046514500 5 J*Y 575/60/3 046741900 205168900 049188400 046514600 7.5 K*Y 575/60/3 047443300 205168800 049188500 046514700 10 L*Y 575/60/3 047443400 205168600 049188600 065821400 15 M*Y 575/60/3 047443500 205166600 049185200 065821500 20 N*Y 575/60/3 049181100 205166800 049188700 065821600 25 P*Y 575/60/3 049181200 205166900 049188800 065821700

Section F- Supply Air SectionSupply Air Fan Motors

Standard Motors: Code 32= **Y

Page 79: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 79

Section F- Supply Air SectionSupply Air Fan Motors, Continued

Shaft Grounded Motors: Code 32= **S

H.P. Motor HP Unit ODP PrEff TEFC PrEff C32= **S Voltage C32= *JS C32= *KS C09= 12 1 E*S 208/60/3 205167699 N/A 1.5 F*S 208/60/3 205167599 N/A 2 G*S 208/60/3 046515599 N/A 3 H*S 208/60/3 300052109 065819499 5 J*S 208/60/3 300052118 065819599 7.5 K*S 208/60/3 065817399 065819699 10 L*S 208/60/3 065817499 065819799 15 M*S 208/60/3 065817599 065819899 20 N*S 208/60/3 065817699 065819999 25 P*S 208/60/3 065817799 065820099 C09= 29 1 E*S 230/60/3 300049695 300049685 1.5 F*S 230/60/3 300049696 300049686 2 G*S 230/60/3 300049697 300049687 3 H*S 230/60/3 300049698 300049688 5 J*S 230/60/3 300049699 300049689 7.5 K*S 230/60/3 300049700 300049690 10 L*S 230/60/3 300049701 065820499 15 M*S 230/60/3 065818599 300049198 20 N*S 230/60/3 065818699 300049691 25 P*S 230/60/3 300049702 300049692 C09= 27 1 E*S 460/60/3 300049695 300049685 1.5 F*S 460/60/3 300049696 300049686 2 G*S 460/60/3 300049697 300049687 3 H*S 460/60/3 300049698 300049688 5 J*S 460/60/3 300049699 300049689 7.5 K*S 460/60/3 300049700 300049690 10 L*S 460/60/3 300049701 065820499 15 M*S 460/60/3 065818599 300049198 20 N*S 460/60/3 065818699 300049691 25 P*S 460/60/3 300049702 300049692 C09= 37 1 E*S 575/60/3 206500999 206505699 1.5 F*S 575/60/3 206501699 205167899 2 G*S 575/60/3 205168399 046514499 3 H*S 575/60/3 046511799 205168499 5 J*S 575/60/3 205168999 046514699 7.5 K*S 575/60/3 205168899 046514799 10 L*S 575/60/3 205168699 065821499 15 M*S 575/60/3 205166699 065821599 20 N*S 575/60/3 205166899 065821699 25 P*S 575/60/3 205166999 065821799N/A= Not Available.

Page 80: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 80

50

4070

71

72

Supply Air OR Return Air Fan Inverter with Bypass Control Box.

(Code 14= 5, 8)Two boxes installed if Code 14= 5

Bypass Controls Detail

Section F- Supply Air SectionInverter & Inverter Bypass Control Box

Motor HP 1- 5 (Code 22 OR Code 32= E*Y, F*Y, G*Y, H*Y, J*Y)03/2013 & Earlier- Diagrams

MMP30 (Supply)MMP40 (Return)

LR10 (Supply)LR20 (Return)

M30B/M30I (Supply)M40B/M40I (Return)

Inverters may be located in a separate section (Code 14= 1, 2, 4 [Only inverters WITH bypass may be installed in a separate section.]), or the Supply Air Section (Code 14= 3, 5, 6, 7, 8, 9). The Inverter and bypass controls are the same regardless of the installation location, although sheet metal components differ. The diagrams shown below apply to either a Return or Supply Air Inverter (both may be installed if Code 14= 5). Even if Code 14= 8, 9— when only a Return Air Fan Inverter is called for— the inverter and bypass controls are still installed in the Supply Air Section.

40

40

Supply Air AND Return Air Fan Inverter without Bypass.

(Code 14= 7)

Supply Air OR Return Air Fan Inverter without Bypass.

(Code 14= 7, 9)MMP & Contactor

Link Detail

73

74

72

70

Page 81: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 81

Section F- Supply Air SectionInverter & Inverter Bypass Control Box

Motor HP 1- 5 (Code 22 OR Code 32= E*Y, F*Y, G*Y, H*Y, J*Y)03/2013 & Earlier- Components

208V

230V

460V

575V

20

8V

230V

460V

575V

20

8V

230V

460V

575V

20

8V

230V

460V

575V

20

8V

230V

460V

575V

1 Line Reactors used when Code 17= CL, CE, CH, CJ, CK, C4, C6, C7, C8, YL, YE, YH, YJ, YK, Y4, Y6, Y7, Y8.2 These are 5% impedance Line Reactors. Some units may have 3% impedance Line Reactors, the 5% may be used in their place. Due

to dimensional differences, minor field modifications may be required for proper installation.

Motor Horsepower 1 1.5 2 3 5

Ref. Sch. Part Part No. Sym. Description Number 40 VFD10, 20 Inverter- see Inverter section

50 Gasket 055940207 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

70 MMP30, 40 Motor Control 349934046 1 1 349934047 1 1 1 349934048 1 1 1 1 349934049 1 1 1 1 1 349934050 1 1 1 349934051 1 349934052 1 1

71 LR10, 20 Line Reactor 1 073323502 1 1 1 073323503 1 073323517 1 1 073323518 1 1 073323533 1 073323541 1 1 1 1 1 1 349964929 2 1 349964953 2 1 1 1 1

72 M30B, I Contactor 349933121 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 M40B, I 349933122 1 1 349933123 1 1

73 Aux. Contact 349933821 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

74 Link Module 349932922 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

Page 82: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 82

50

40

70

71

72Supply Air OR Return Air Fan Inverter

with Bypass Control Box.(Code 14= 5, 8)

Two boxes installed if Code 14= 5Bypass Controls Detail

Section F- Supply Air SectionInverter & Inverter Bypass Control Box

Motor HP 1- 5 (Code 22 OR Code 32= E**, F**, G**, H**, J**)4/2013 & Later- Diagrams

MMP40 (Return)

LR10 (Supply)

M30B/M30I (Supply)

40

40

Supply Air AND Return Air Fan Inverter without Bypass.

(Code 14= 7)

Supply Air OR Return Air Fan Inverter without Bypass.

(Code 14= 7, 9)

LR20 (Return)

71

MMP30 (Supply)

70

72M40B/M40I (Return)

Inverters may be located in a separate section (Code 14= 1, 2, 4 [Only inverters WITH bypass may be installed in a separate section.]), or the Supply Air Section (Code 14= 3, 5, 6, 7, 8, 9). The Inverter and bypass controls are the same regardless of the installation location, although sheet metal components differ. The diagrams shown below apply to either a Return or Supply Air Inverter (both may be installed if Code 14= 5). Even if Code 14= 8, 9— when only a Return Air Fan Inverter is called for— the inverter and bypass controls are still installed in the Supply Air Section.

Page 83: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 83

Section F- Supply Air SectionInverter & Inverter Bypass Control Box

Motor HP 1- 5 (Code 22 OR Code 32= E**, F**, G**, H**, J**)4/2013 & Later- Components

208V

230V

460V

575V

20

8V

230V

460V

575V

20

8V

230V

460V

575V

20

8V

230V

460V

575V

20

8V

230V

460V

575V

MMP

70

Link 70C

Contactor

72

Front Mtd.Aux. Contact

70B

MMP30/40 & M30/40 Link Detail1- 2 HP Motors- All Voltages

3, 5 HP Motors- 460/575V

MMP30/40 & M30/40 Link Detail3, 5 HP Motors- 208/230V

MMP

70B

Contactor72

7070APhase Barrier

Spacer72A

70APhase Barrier

Front Mtd.Aux. Contact

Link 70C

Motor Horsepower 1 1.5 2 3 5

Ref. Sch. Part Part No. Sym. Description Number 40 VFD10, 20 Inverter- see Inverter section 50 Gasket 055940207 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 70 MMP30, 40 Motor Protector 193542904 1 1 193542905 1 1 193542907 1 193542908 1 1 1 193542909 1 1 193542910 1 1 193542911 1 193542912 1 1 1 193543007 1 1 193543009 1 1 70A Phase Barrier 193545501 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 70B Aux. Contact 193543801 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 70C Link 193545901 1 1 1 1 1 1 1 1 1 1 1 1 193546001 1 1 1 1 71 LR10, 20 Line Reactor 1 073323502 1 1 1 1 073323503 1 073323517 1 1 073323518 1 1 073323533 1 073323541 1 1 1 1 1 1 349964929 2 1 349964953 2 1 1 1 1 72 M30B, I Contactor 193592105 1 1 M40B, I 193592106 1 193539105 1 1 1 1 1 1 1 1 1 1 1 1 1 1 193539106 1 1 193539304 1 72A Spacer 193545801 2 2 2 2 1 Line Reactors used when Code 17= CL, CE, CH, CJ, CK, C4, C6, C7, C8, YL, YE, YH, YJ, YK, Y4, Y6, Y7, Y8.2 These are 5% impedance Line Reactors. Some units may have 3% impedance Line Reactors, the 5% may be used in their place. Due

to dimensional differences, minor field modifications may be required for proper installation.

Page 84: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 84

50

40

70

71

72Supply Air OR Return Air Fan

Inverter w/ Bypass Control Box.

(Code 14= 5, 8)Two boxes installed if C14= 5

Bypass Controls Detail

Section F- Supply Air SectionInverter & Inverter Bypass Control Box

Motor HP 7.5- 25 (Code 22 = K*Y, L*Y, M*Y, N*Y OR Code 32= K*Y, L*Y, M*Y, N*Y, P*Y)

03/2013 & Earlier- Diagrams

MMP30 (Supply)MMP40 (Return)

LR10 (Supply)LR20 (Return)

M30B/M30I (Supply)M40B/M40I (Return)

MMP & Contactor Link DetailMMP p/n 349934147, 48, 49

MMP & Contactor Link DetailMMP p/n 3499340xx

MMP & Contactor Link DetailMMP p/n 349938606

40

Supply Air AND Return Air Fan

Inverter without Bypass.

(Code 14= 7)

72

70

40

Supply Air OR Return Air Fan

Inverter without Bypass.

(Code 14= 7, 9)

72

70

73

70

73

73

72

77

76

Page 85: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 85

Section F- Supply Air SectionInverter & Inverter Bypass Control Box

Motor HP 7.5- 25 (Code 22 = K*Y, L*Y, M*Y, N*Y OR Code 32= K*Y, L*Y, M*Y, N*Y, P*Y)

03/2013 & Earlier- Components

208V

230V

460V

575V

20

8V

230V

460V

575V

20

8V

230V

460V

575V

20

8V

230V

460V

575V

20

8V

230V

460V

575V

Motor Horsepower 7.5 10 15 20 25

Ref. Sch. Part Part No. Sym. Description Number 40 VFD10,20 Inverter- see Inverter section

50 Gasket 055940207 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

70 MMP30, 40 Motor Control 349934050 1 349934051 1 1 349934052 1 1 349934053 1 1 1 349934054 1 1 349934055 1 1 349934147 1 1 349934148 1 1 349934149 1 1 1 349938606 1

71 LR10, 20 Line Reactor 1 073323504 1 073323505 1 073323506 1 073323507 1 073323511 1 1 073323512 1 1 073323519 1 1 073323520 1 1 073323521 1 1 073323534 1 349964926 2 1 349964927 2 1 349964930 2 1 349964931 2 1 349964932 2 11 Line Reactors used when Code 17= CL, CE, CH, CJ, CK, C4, C6, C7, C8, YL, YE, YH, YJ, YK, Y4, Y6, Y7, Y8.2 These are 5% impedance Line Reactors. Some units may have 3% impedance Line Reactors, the 5% may be used in their place. Due

to dimensional differences, minor field modifications may be required for proper installation.

Page 86: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 86

208V

230V

460V

575V

20

8V

230V

460V

575V

20

8V

230V

460V

575V

20

8V

230V

460V

575V

20

8V

230V

460V

575V

Section F- Supply Air SectionInverter & Inverter Bypass Control Box

Motor HP 7.5- 25 (Code 22 = K*Y, L*Y, M*Y, N*Y OR Code 32= K*Y, L*Y, M*Y, N*Y, P*Y)

03/2013 & Earlier- Components, Continued

Motor Horsepower 7.5 10 15 20 25

Ref. Sch. Part Part No. Sym. Description Number 72 M30B,I Contactor 349933121 1 M40B,I 349933122 1 1 349933123 1 1 349933321 1 1 1 1 349933322 1 1 1 349933521 1 1 349933522 1 1 349933523 1 1 349933621 1 1

73 Contact- Auxiliary 349933922 1 1 1 1 1 1 1 1 1 1 1 1 1 349933821 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

74 Link 349932922 1 1 1 1 1 1 1 1 1 1 1 1 1

76 Interlock- Trip 349938701 1

77 Lug Kit (3 per kit) 349938801 2

Page 87: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 87

50

40

Supply Air OR Return Air Fan Inverter w/ Bypass Control

Box.(Code 14= 5, 8)

Two boxes installed if C14= 5

Section F- Supply Air SectionInverter & Inverter Bypass Control Box

Motor HP 7.5- 25 (Code 22 = K**, L**, M**, N** OR Code 32= K**, L**, M**, N**, P**)

4/2013 & Later- Diagrams

40

Supply Air AND Return Air Fan

Inverter without Bypass.

(Code 14= 7)

40

Supply Air OR Return Air Fan

Inverter without Bypass.

(Code 14= 7, 9)

7071

72

Bypass Controls Detail

MMP40 (Return)LR10 (Supply)

M30B/M30I (Supply)

LR20 (Return)MMP30 (Supply)

70

72M40B/M40I (Return)

MMP30/40 & M30/40 Link Detail7.5 HP Motors- 208/230/460V

10, 15 HP Motors- 460V

MMP

70B

Contactor72

70

Spacer72A

70APhase Barrier

Front Mtd.Aux. Contact

Link 70C

MMP

70

Link 70C

Contactor

72

Front Mtd.Aux. Contact

70B

MMP30/40 & M30/40 Link Detail7.5 HP Motors- 575V

70APhase Barrier

MMP30/40 & M30/40 Link Detail10, 15 HP Motors- 208/230V

15, 20 HP Motors- 575V 20 HP Motors- 460V

25 HP Motors- 460/575V

MMP30/40 & M30/40 Link Detail20, 25 HP Motors- 208/230V

MMP

70

Link 70C

Contactor

72

Front Mtd.Aux. Contact

70B

MMP

70

Link 70C

Contactor

72

Front Mtd.Aux. Contact

70B70APhase Barrier

71

Page 88: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 88

Section F- Supply Air SectionInverter & Inverter Bypass Control Box

Motor HP 7.5- 25 (Code 22 = K**, L**, M**, N** OR Code 32= K**, L**, M**, N**, P**)

4/2013 & Later- Components

208V

230V

460V

575V

20

8V

230V

460V

575V

20

8V

230V

460V

575V

20

8V

230V

460V

575V

20

8V

230V

460V

575V

Motor Horsepower 7.5 10 15 20 25

Ref. Sch. Part Part No. Sym. Description Number 40 VFD10, 20 Inverter- see Inverter section

50 Gasket 055940207 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

70 MMP30 ,40 Motor Protector 193542913 1 193543008 1 1 193543009 1 193543010 1 193543011 1 193543012 1 193543301 1 193543303 1 193543304 1 1 1 1 1 193543305 1 193543306 1 193543403 1 1 1 193543404 1

70A Phase Barrier 193545501 1 1 1 1 1 1 1 193547301 1 1 1 1

70B Contact- Auxiliary 193543801 1 1 1 1 1 1 1 193546201 1 1 1 1 1 1 1 1 1 1 1 1 1

70C Link 193545901 1 193546001 1 1 1 1 1 1 193547401 1 1 1 1 1 1 1 1 1 193547501 1 1 1 1

Page 89: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 89

Motor Horsepower 7.5 10 15 20 25

Ref. Sch. Part Part No. Sym. Description Number

208V

230V

460V

575V

20

8V

230V

460V

575V

20

8V

230V

460V

575V

20

8V

230V

460V

575V

20

8V

230V

460V

575V

Section F- Supply Air SectionInverter & Inverter Bypass Control Box

Motor HP 7.5- 25 (Code 22 = K**, L**, M**, N** OR Code 32= K**, L**, M**, N**, P**)

4/2013 & Later- Components, Continued

71 LR10, 20 Line Reactor 1 073323504 1 073323505 1 073323506 1 073323507 1 073323511 1 1 073323512 1 1 073323519 1 1 073323520 1 1 073323521 1 1 073323534 1 349964926 1 349964927 1 349964930 1 349964931 1 349964932 1

72 M30B, I M40B, I Contactor 9A 193539106 1 12A 193592105 1 1 16A 193592106 1 25A 193539304 1 1 1 1 1 32A 193539501 1 1 1 1 1 50A 193539502 1 1 65A 193539601 1 1 80A 193539602 1 1

72A Spacer 193545801 2 2 2 2 2 2 1 Line Reactors used when Code 17= CL, CE, CH, CJ, CK, C4, C6, C7, C8, YL, YE, YH, YJ, YK, Y4, Y6, Y7, Y8.

Page 90: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 90

Section F- Supply Air SectionInverters

Code 15= A AND/OR Code 23 (Mid 2012 & Later)= **A** 1

Motor Horsepower 1 1.5 2 3 5 7.5 10 15 20 25

Part Number 098861454 1 098861455 1 098861456 1 098861457 1 098861458 1 098861459 1 098861467 1 1 1 1 098861468 1 098861469 1 098861470 1

208/

230V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

Code 15= R 2

Motor Horsepower 1 1.5 2 3 5 7.5 10 15 20 25

Part Number 099488004 1 1 1 1 099488103 1 1 1 1 193552326 1 1 1 1 099488005 1 099488104 1 193552327 1 099488006 1 099488105 1 193552328 1 099488007 1 099488106 1 193552329 1 099488008 1 099488107 1 193552330 1 193552319 1 099488108 1 193552331 1 193552320 1 099488109 1 193552332 1

208/

230V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

1 The replacement VFD Keypad Display is p/n 300040924.

2 Note that the manufacturer has made changes to this inverter line. BEFORE ORDERING contact Daikin Applied to ensure compatibility and that no additional components are required for proper installation and operation.

Page 91: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 91

Section F- Supply Air SectionInverters, Continued

Motor Horsepower 1, 1.5, 2 3 5 7.5 10 15 20 25

Part Number 098656914 1 098656924 1 205858855 1 098656943 1 1 1 098656915 1 098656925 1 300049996 1 098656916 1 098656926 1 205858822 1 205858813 1 098656927 1 098656904 1 098656944 1 205858814 1 098656928 1 205858824 1 098656945 1 098656919 1 098656929 1 098656906 1 098656946 1 205858816 1 098656930 1 205858826 1 098656947 1 098656921 1 098656931 1 098656908 1 098656948 1

208V

230V

460V

575V

20

8V

230V

460V

575V

20

8V

230V

460V

575V

20

8V

230V

460V

575V

20

8V

230V

460V

575V

20

8V

230V

460V

575V

20

8V

230V

460V

575V

208V

230V

460V

575V

Code 15= G

Page 92: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 92

Section F- Supply Air SectionInverters, Continued

Motor Horsepower 1 1.5 2 3 5 7.5 10 15 20 25

Part Number 193475806 1 1 1 1 193475822 1 1 1 1 193456302 2, 4 1 1 1 193475807 1 1 193475823 1 1 193456303 2, 4 1 193475809 1 1 193475825 1 1 193456304 2, 4 1 193475810 1 1 193475826 1 1 193456305 2, 4 1 193475811 1 1 193475827 1 1 193456306 2, 4 1 193475812 1 1 193475828 1 1 193456307 2, 4 1 193475813 1 1 193475829 1 1 193456308 2, 4 1 193475814 1 1 193475830 1 1 349956647 3 1

208/

230V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

Code 15= S, Q AND/OR Code 23 (Mid 2012 & Later)= **Q**

1 Units built late 2010 & earlier shipped with ATV21 VFDs. All ATV21 drives have been replaced with ATV212 drives as listed above. These new drives are drop in replacements with the exception of the Remote Keypad and Communication Cards. The ATV21 Remote Keypad is p/n 349958801. The ATV21 Lonworks communication card is p/n 349927103. The ATV212 Remote Keypad is p/n 349958805 and the Remote Keypad Mounting kit is p/n 349958803. The ATV212 Lonworks communication card is p/n 193482601. All other ATV212 communication cards are integral to the VFD and are not available separately. Note that since the original ATV21 drives are obsolete and unavailable, when at zero stock, repair parts are also not available. If an obsolete ATV21 part fails, the entire drive must be replaced.

2 MD3 Remote Keypad p/n is 349958802.3 MD6 Remote Keypad p/n is 349958805 plus Mount p/n 349958803.4 For 575V units with an MD3 Inverter and Motor under 25 HP a Line Reactor will be installed regardless of whether one is specified in

Code 17 (see nomenclature page).

Page 93: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 93

Section F- Supply Air SectionInverters, Continued

Code 15= B OR Code 23 (Mid 2012 & Later)= **B** 1

Motor Horsepower 1 1.5 2 3 5 7.5 10 15 20 25

Part Number 193552243 1 193552293 1 193552397 1 193552245 1 1 193552295 1 1 193552326 1 1 1 193552246 1 193552296 1 193552215 1 193552202 1 193552327 1 193552216 1 193552203 1 193552328 1 193552217 1 193552204 1 193552329 1 193552218 1 193552205 1 193552330 1 193552319 1 193552206 1 193552331 1 193552320 1 193552207 1 193552332 11 The replacement VFD Keypad Display is p/n 300040924.

208/

230V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

208

/230

V

460V

575V

Page 94: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 94

Ref. Part Part Qty. No. Description Number 15 Bracket 1 1 19 Pressure Control- PC7 1 1 20 Pneumatic Fitting 1 1

PC7- Proof of Airflow Pressure Control

Ref. Part Part Qty. No. Description Number 67 T-stat- HL22 Hi Limit 047938801 1 67A Support- HL22 058379401 1

HL22- Gas Heat Hi Limit Switch Code 04= A

LT10- Supply Fan Light/S10- Supply Fan Light Switch/REC10- Supply Fan Light ReceptacleCode 49= B, E

Ref. Part Part Qty. No. Description Number 98 Light Fixture- 18" Bulb 205484001 1 Light Fixture- 24" Bulb 205484101 1 Light Fixture- 36" Bulb 205484201 1 99 Bulb/Lamp, UV- 18" 205484501 1 Bulb/Lamp, UV- 24" 205484601 1 Bulb/Lamp, UV- 36" 205484701 1

UV Lights Code 17= C1 thru C8 AND Y1 thru Y8

Ref. Part Part Qty. No. Description Number 36 Sensor- EFT 193414602 1 37 Bracket- EFT 059651301 1

EFT- Entering Fan Temperature Sensor

19

15

20

36

37

67

84 85

88 89

98

99

Section F- Supply Air SectionSection Mounted Controls

PC7, EFT, HL22, LT10, S10, REC10, UV Lights

67A

1 In mid 2012 the design of PC7 was changed. Units equipped with the old style PC7 require Retrofit Kit 910122413 for proper installation as old and new parts are NOT interchangeable. The Control only is p/n 910115489, the Pneumatic Fitting is p/n 910122414, and the Support Bracket is p/n 910122290.

Ref. Part Part Qty. No. Description Number 84 Light Fixture 6/13 & Earlier 042229500 1 Light Fixture 7/13 & Later 910145007 1 85 Bulb- LT10 065492402 1 88 Light Switch- S10 065492201 1 89 Receptacle- REC10 030187000 1

Page 95: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 95

Section G- BlowThru Heat SectionNotes

Primary Codes that pertain: 04, 34Additional Codes that pertain: 06, 07, 09, 12, 31

This section is divided into four subsections: 1. Blank/Empty; 2. HW/Steam Heat; 3. Electric Heat; and 4. Natural Gas Heat.

Code 04 determines what type of heat, if any, the unit employs, and Code 34 defines the specific heat section's characteristics. If Code 04= Y, AND Code 34= YYYYYY there is no section. If Code 04= Y AND Code 34= BBBBBB, then there is a 40" Blank/Empty Section installed.

Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the BlowThru Heating Section, contact Daikin Applied with model and serial number information to ensure correct liners, insulation and hardware are ordered. For standard Access Door Latching Assemblies, see Section H.

Code 07 is the Gas Heat Burner Approval Code and affects many of the parts in the gas heat section depending on whether the unit is UL approved (USA) or ETL approved (Canada).

Code 09 determines the Unit Voltage, which will have an effect on the Electric Heaters and their controls.

Code 12 determines the Control type and will affect the Gas Heat Actuator.

Code 31 is the Supply Fan size, and affects the heat section's Diffusers.

Page 96: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 96

Section G- BlowThru Heat Section Option 1: Blank/Empty Section

Code 34= BBBBBB AND Code 04= Y Diffusers

12

12

Units with 15" X 6" OR 15" X 15" Supply FanCode 31= 06F*, 15F*

Units with 20" OR 24" Supply FanCode 31= 20**, 24**

Ref. Part Part Qty. No. Description Number 12 Diffuser Code 31= 06F*, 15F* 035165700 2 Code 31= 20**, 24** 031744400 1

Page 97: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 97

Section G- BlowThru Heat SectionOption 2: Hot Water OR Steam Heating Coil

Code 04= W, SCoils and Coil Compartment Components

DiffuserUnits with 15" Supply Fan

Code 31= 06F*, 15F*

DiffuserUnits with 20" OR 24" Supply Fan

Code 31= 20**, 24**

12

12

Ref. Part Part Qty. No. Description Number 2 Coil, Hot Water 8/12 & Earlier 1

Hot Water- 9 FPI/1 Row (C34= W11***) 056053045 1 1 Hot Water- 9 FPI/2 Row (C34= W22***) 056053046 1 1 2 Coil, Hot Water 1/13 & Later 1

Hot Water- 9 FPI/1 Row (C34= W11***) 404090406 1 1 Hot Water- 9 FPI/2 Row (C34= W22***) 404090405 1 1 2 Coil, Steam Steam Coil- 6 FPI/1 Row (C34= S11***) 056053041 1 1 Steam Coil- 12 FPI/1 Row (C34= S12***) 056053042 1 1 12 Diffuser Code 31= 06F*, 15F* 035165700 2 Code 31= 20**, 24** 031744400 1 108 Fin Channel (1- Row Coil Only) 066634801 2 120 Bottom Baffle (C36= 5Z**** only) 1 Row Coil (C34= W11***, S11***) 058458601 1 2 Row Coil (C34= W22***) 058466501 1 711 Freezestat- FS1 072502001 1

711

FS1 Freezestat

1 For units built during the transition, use the Distributor Tools BOM Search function on the Daikin Parts website or contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified.

120

108

108

2

Page 98: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 98

Section G- BlowThru Heat SectionOption 2: Hot Water OR Steam Heating CoilCode 04= W, S AND Code 34= W****E, S****E

Valves

Steam Coil UnitsCode 34= S11*2E, S12*2E

Hot Water Coil UnitsCode 34= W11*3E, W22*3E

249

Ref. Sch. Part Code Coil Coil Part Qty. No. Sym. Description 34= Type Height Number 249 Valve, 2 Way Steam Heat w/ Act.1

1.00” S**D2E 5JA All 113147301 1 1.25” S**E2E 5JA All 113147501 1 1.50” S**F2E 5JA All 113147701 1 2.00” S**G2E 5JA All 113147901 1 163 VM1 Actuator- 24V, HW Heat 2 W***3E All All 300046566 1 263 Valve, 3 Way HW w/ Actuator 1.00” W**D3E 5WH, 5WS All 1 1.25” W**E3E 5WH, 5WS All 113166703 1 1.50” W**F3E 5WH, 5WS All 113166704 1 2.00” W**G3E 5WH, 5WS All 113166705 1N/S= Not shown on diagram.1 Note that the Steam Valve is factory supplied WITH the Actuator. For Actuator ONLY p/ns contact Daikin Applied with model and

serial number information so that the correct Actuator can be identified. 2 Note that the HW Valve is factory supplied WITH the Actuator. Use this p/n when replacing the HW Actuator ONLY.

163

263

Page 99: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 99

Section G- BlowThru Heat SectionOption 3: Electric Heat

Code 04= EDiffusers, High Limit HL4, HL14 & HL 31- 50

Ref. Part Part Qty. No. Description Number 12 Diffuser Code 31= 06F*, 15F* 035165700 2 Code 31= 20**, 24** 032438600 1 34 Hi Limit- HL4, HL14 028398200 2 31- 52 Heaters- See charts on following page N/S Hi Limit Switches: HL31- 50 (part of heater assys.) 028396300 var.

12

Diffusers:Units with 15" Supply Fan

Code 31= 06F*, 15F*

Units with 20" OR 24" Supply FanCode 31= 20**, 24**

Heaters, Hi-Limit Switches

Control Box

(see page after next)

34

HL4

HL14

32

51

52

42

31

41

12

Page 100: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 100

Heater KW- Code 34= Ref. E020** E040** E060** E080** E100** E120** E140** E160** E180** E200** E220** E240** No. Qty. 20kw 40kw 60kw 80kw 100kw 120kw 140kw 160kw 180kw 200kw 220kw 240kw 31 1 A B C D D D D D N/A N/A N/A N/A 32 1 A B C D D D D D N/A N/A N/A N/A 41 1 U U U U A B C D N/A N/A N/A N/A 42 1 N/A N/A N/A N/A A B C D N/A N/A N/A N/A 51 1 U U U U U U U U N/A N/A N/A N/A 52 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A

Section G- BlowThru Heat SectionOption 3: Electric Heat

Code 04= EElectric Heating Assemblies and Elements

Heater Cross Reference: 208/230/60/3 Units (Code 09= 12, 29)This chart represents a where-used for each KW. Ref. letter U= blank filler piece, part #031141400 (Qty. = 1).

Heater KW- Code 34= Ref. E020** E040** E060** E080** E100** E120** E140** E160** E180** E200** E220** E240** No. Qty. 20kw 40kw 60kw 80kw 100kw 120kw 140kw 160kw 180kw 200kw 220kw 240kw 31 1 E F G H G G H H G H H H 32 1 E F G H G G H H G H H H 41 1 U U U U F G G H G G H H 42 1 N/A N/A N/A N/A F G G H G G H H 51 1 U U U U U U U U G G G H 52 N/A N/A N/A N/A N/A N/A N/A N/A G G G H

Heater Cross Reference: 380/50/3 & 460/60/3 Units (Code 09= 27, 28)This chart represents a where-used for each KW. Ref. letter U= blank filler piece, part #031141400 (Qty. = 1).

Heater KW- Code 34= Ref. E020** E040** E060** E080** E100** E120** E140** E160** E180** E200** E220** E240** No. Qty. 20kw 40kw 60kw 80kw 100kw 120kw 140kw 160kw 180kw 200kw 220kw 240kw 31 1 I J K L K K L L K L L L 32 1 I J K L K K L L K L L L 41 1 U U U U J K K L K K L L 42 1 N/A N/A N/A N/A J K K L K K L L 51 1 U U U U U U U U K K K L 52 N/A N/A N/A N/A N/A N/A N/A N/A K K K L

Heater Cross Reference: 575/60/3 Units (Code 09= 37)This chart represents a where-used for each KW. Ref. letter U= blank filler piece, part #031141400 (Qty. = 1).

Ref. Letter A B C D E F Complete Assy. 028513401 028513402 028513403 028513404 028513501 028513502 Heater Assy. 029588701 029588702 029588501 029588502 029588701 029588702 Element Only 024670430 024670433 024670430 024670433 024670430 024670433 (6) (6) (6) (12) (6) (6) Ref. Letter G H I J K L Complete Assy. 028513503 028513504 035705801 035705802 035705803 035705804 Heater Assy. 029588501 029588502 035705901 035705902 035705701 035705702 Element Only 024670430 024670433 024670438 024670437 024670438 024670437 (6) (6) (6) (12) (6) (6)

This chart defines the letters used in the charts below. Complete assemblies include heater elements, hardware and the control HiLimit switch (HL31- 50). The Heater Assembly contains the elements less the HiLimit Control and its associated hardware. DUE TO MANY AVAILABLE SPECIAL HEATER OPTIONS, BE VERY CAREFUL SELECTING HEATER AND HEATER COMPONENTS TO ENSURE CORRECT HEATER SELECTION.

Page 101: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 101

Power Panel Detail

Con

trol

Pan

el

Control Panel Detail

FB33 FB32 FB31

M33 M32 M31

FB43 FB42 FB41

M43 M42 M41

F33

F33

F33

F32

F32

F32

F31

F31

F31

F43

F43

F43

F42

F42

F42

F41

F41

F41

PB3

SR2

SR3

SR1

T5

SR2

SR3

SR1

T5

R23

TB11

R23

TB11

Section G- BlowThru Heat SectionOption 3: Electric Heat Code 04= E

Electric Heat Control BoxNo Controls (Code 12= YM)

Diagrams

Page 102: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 102

Heater KW= 20/40 60 80 100 120 140 160 180 Sch. Part Part Sym. Description Number PB3 Power Block 030372777 1 1 1 1 1 1 1 1 1 1 1 1 030372785 1 1 1 1 1 1 1 1 1 1 1 1 1 1 030372786

TB11 Terminal Block 349930641 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

R23 Relay- DPDT 349934724 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Socket- R23 349934822 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 T5 Transformer 349937203 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

SR1 Ctl- Sequencer 031002304 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 SR2 Ctl- Sequencer 031002304 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 SR3 Ctl- Sequencer 031002304 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

208V

230V

460V

575V

208

V23

0V46

0V57

5V 2

08V

230V

460V

575V

208

V23

0V46

0V57

5V 2

08V

230V

460V

575V

460V

575V

460V

575V

460V

575V

1 Part number is for one section. The number of sections used is determined by the options installed.

Relays, Power Block, Terminal Block, T5 Transformer and Control Sequencer

Section G- BlowThru Heat SectionOption 3: Electric Heat Code 04= E

Electric Heat Control BoxNo Controls (Code 12= YM)

Components

Heater KW= 20/40 60 80 100 120 140 160 180 Sch. Part Part Sym. Description Number FB31 Fuse Block 023780229 1 1 1 1 1 1 1 1 1 1 023780225 1 1 1 1 023780230 1 1 1 1 1 1 1 1 1 1 1 1 FB32 Fuse Block 023780229 1 1 1 1 1 1 1 1 023780225 1 1 023780230 1 1 1 1 1 1 1 1 FB33 Fuse Block 023780229 1 1 1 1 023780230 1 1 FB41 Fuse Block 023780229 1 1 1 1 1 1 1 1 1 1 023780225 1 1 1 1 023780230 1 1 1 1 1 1 1 1 1 1 1 1 FB42 Fuse Block 023780229 1 1 1 1 1 1 1 1 023780225 1 1 023780230 1 1 1 1 1 1 1 1 FB43 Fuse Block 023780229 1 1 1 1 023780230 1 1

208V

230V

460V

575V

208

V23

0V46

0V57

5V 2

08V

230V

460V

575V

208

V23

0V46

0V57

5V 2

08V

230V

460V

575V

460V

575V

460V

575V

460V

575V

Fuse Blocks

Page 103: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 103

Heater KW= 20/40 60 80 100 120 140 160 180 200 220 240 Sch. Part Part Sym. Description Number F31 Fuse 025860408 3 025860409 3 025860411 3 025860412 3 3 3 025860413 3 3 3 3 3 3 3 025860414 3 3 3 3 3 3 3 3 3 025860511 025860512 025860514 3 3 3 3 3 3 3 3 3 3

F32 Fuse 025860408 3 025860409 3 025860412 3 025860413 3 3 3 3 3 025860414 3 3 3 3 3 3 3 3 025860511 3 025860512 3 025860514 3 3 3 3 3 3

F33 Fuse 025860413 3 3 3 025860414 3 3 3 3 3 025860514 3 3 3 3

F41 Fuse 025860408 3 025860409 3 025860411 3 025860412 3 3 3 025860413 3 3 3 3 3 3 3 025860414 3 3 3 3 3 3 3 3 3 025860511 025860512 025860514 3 3 3 3 3 3 3 3 3 3

F42 Fuse 025860408 3 025860409 3 025860412 3 025860413 3 3 3 3 3 025860414 3 3 3 3 3 3 3 3 025860511 3 025860512 3 025860514 3 3 3 3 3 3

F43 Fuse 025860413 3 3 3 025860414 3 3 3 3 3 025860514 3 3 3 3

208V

230V

460V

575V

208

V23

0V46

0V57

5V 2

08V

230V

460V

575V

208

V23

0V46

0V57

5V 2

08V

230V

460V

575V

460V

575V

460V

575V

460V

575V

460V

575V

460V

575V

460V

575V

Section G- BlowThru Heat SectionOption 3: Electric Heat Code 04= E

No Controls (Code 12= YM)Components, Continued

Fuses

Page 104: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 104

Section G- BlowThru Heat SectionOption 3: Electric Heat Code 04= E

Electric Heat Control BoxNo Controls (Code 12= YM)

Components, Continued

Heater KW= 20/40 60 80 100 120 140 160 180 200 220 240 Sch. Part Part Sym. Description Number M31 Contactor 349932321 1 1 Contactor 349932322 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 M32 Contactor 349932322 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Contactor 349932321 1 1 M33 Contactor 349932322 1 1 1 1 1 1 1 1 1 1 1 1 M41 Contactor 349932321 1 1 1 1 Contactor 349932322 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 M42 Contactor 349932322 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Contactor 349932321 1 1 M43 Contactor 349932322 1 1 1 1 1 1 1 1 1 1 1 1

208V

230V

460V

575V

208

V23

0V46

0V57

5V 2

08V

230V

460V

575V

208

V23

0V46

0V57

5V 2

08V

230V

460V

575V

460V

575V

460V

575V

460V

575V

460V

575V

460V

575V

460V

575V

Contactors: (03/2013 & Earlier)

Heater KW= 20/40 60 80 100 120 140 160 180 200 220 240 Sch. Part Part Sym. Description Number M31 Contactor 193592005 1 1 Contactor 193591601 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 M32 Contactor 193591601 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Contactor 193592005 1 1 M33 Contactor 193591601 1 1 1 1 1 1 1 1 1 1 1 1 M41 Contactor 193592005 1 1 1 1 Contactor 193591601 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 M42 Contactor 193591601 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Contactor 193592005 1 1 M43 Contactor 193591601 1 1 1 1 1 1 1 1 1 1 1 1

208V

230V

460V

575V

208

V23

0V46

0V57

5V 2

08V

230V

460V

575V

208

V23

0V46

0V57

5V 2

08V

230V

460V

575V

460V

575V

460V

575V

460V

575V

460V

575V

460V

575V

460V

575V

Contactors: (04/2013 & Later)

Page 105: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 105

Section G- BlowThru Heat SectionOption 3: Electric Heat Code 04= E

Electric Heat Control BoxMicroTech III (Code 12= *E, *F, *W)

Diagram 1

1 The above diagram shows a typical Electric Heat Control Box layout and is to be used for reference only. Specific unit configuration and components used differ depending upon options selected.

Page 106: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 106

Section G- BlowThru Heat SectionOption 3: Electric Heat Code 04= E

Electric Heat Control BoxMicroTech III Units (Code 12= *E, *F, *W)

Components

Heater KW= 20/40 60 80 100 120 140 160 180 200 220 240 Sch. Part Part Sym. Description Number Fuse-F31 025860408 3 025860409 3 025860411 3 025860412 3 3 3 025860413 3 3 3 3 3 3 3 025860414 3 3 3 3 3 3 3 3 3 025860511 025860512 025860514 3 3 3 3 3 3 3 3 3 3

Fuse-F32 025860408 3 025860409 3 025860412 3 025860413 3 3 3 3 3 025860414 3 3 3 3 3 3 3 3 025860511 3 025860512 3 025860514 3 3 3 3 3 3

Fuse-F33 025860413 3 3 3 025860414 3 3 3 3 3 025860514 3 3 3 3

Fuse-F41 025860408 3 025860409 3 025860411 3 025860412 3 3 3 025860413 3 3 3 3 3 3 3 025860414 3 3 3 3 3 3 3 3 3 025860511 025860512 025860514 3 3 3 3 3 3 3 3 3 3

Fuse-F42 025860408 3 025860409 3 025860412 3 025860413 3 3 3 3 3 025860414 3 3 3 3 3 3 3 3 025860511 3 025860512 3 025860514 3 3 3 3 3 3

Fuse-F43 025860413 3 3 3 025860414 3 3 3 3 3 025860514 3 3 3 3

208V

230V

460V

575V

208

V23

0V46

0V57

5V 2

08V

230V

460V

575V

208

V23

0V46

0V57

5V 2

08V

230V

460V

575V

460V

575V

460V

575V

460V

575V

460V

575V

460V

575V

460V

575V

Fuses

Page 107: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 107

Heater KW= 20/40 60 80 100 120 140 160 180 200 220 240 Sch. Part Part Sym. Description Number FB31 Fuse Block 023780229 1 1 1 1 1 1 1 1 1 1 023780225 1 1 023780230 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

FB32 Fuse Block 023780229 1 1 1 1 1 1 1 1 023780225 1 1 023780230 1 1 1 1 1 1 1 1 1 1 1 1 1 1

FB33 Fuse Block 023780229 1 1 1 1 023780230 1 1 1 1 1 1 1 1

FB41 Fuse Block 023780229 1 1 1 1 1 1 1 1 1 1 023780225 1 1 023780230 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

FB42 Fuse Block 023780229 1 1 1 1 1 1 1 1 023780225 1 1 023780230 1 1 1 1 1 1 1 1 1 1 1 1 1 1

FB43 Fuse Block 023780229 1 1 1 1 023780230 1 1 1 1 1 1 1 1 PB3 Power Block 030372777 1 1 1 1 1 1 1 1 1 1 1 1 030372785 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

TB11 Terminal Block 349930641 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

208V

230V

460V

575V

208

V23

0V46

0V57

5V 2

08V

230V

460V

575V

208

V23

0V46

0V57

5V 2

08V

230V

460V

575V

460V

575V

460V

575V

460V

575V

460V

575V

460V

575V

460V

575V

Section G- BlowThru Heat SectionOption 3: Electric Heat Code 04= E

Electric Heat Control BoxMicroTech III Units (Code 12= *E, *F, *W)

Components, Continued

1 Part number is for one section. The number of sections used is determined by the options installed.

Fuse & Terminal Blocks

Page 108: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 108

Section G- BlowThru Heat SectionOption 3: Electric Heat Code 04= E

Electric Heat Control BoxMicroTech III (Code 12= *E, *F, *W)

Components, Continued

Heater KW= 20/40 60 80 100 120 140 160 180 200 220 240 Sch. Part Part Sym. Description Number M31 Contactor 349932321 1 1 Contactor 349932322 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 M32 Contactor 349932322 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Contactor 349932321 1 1 M33 Contactor 349932322 1 1 1 1 1 1 1 1 1 1 1 1 M41 Contactor 349932321 1 1 1 1 Contactor 349932322 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 M42 Contactor 349932322 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Contactor 349932321 1 1 M43 Contactor 349932322 1 1 1 1 1 1 1 1 1 1 1 1

208V

230V

460V

575V

208

V23

0V46

0V57

5V 2

08V

230V

460V

575V

208

V23

0V46

0V57

5V 2

08V

230V

460V

575V

460V

575V

460V

575V

460V

575V

460V

575V

460V

575V

460V

575V

Contactors: (03/2013 & Earlier)

Heater KW= 20/40 60 80 100 120 140 160 180 200 220 240 Sch. Part Part Sym. Description Number M31 Contactor 193592005 1 1 Contactor 193591601 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 M32 Contactor 193591601 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Contactor 193592005 1 1 M33 Contactor 193591601 1 1 1 1 1 1 1 1 1 1 1 1 M41 Contactor 193592005 1 1 1 1 Contactor 193591601 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 M42 Contactor 193591601 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Contactor 193592005 1 1 M43 Contactor 193591601 1 1 1 1 1 1 1 1 1 1 1 1

208V

230V

460V

575V

208

V23

0V46

0V57

5V 2

08V

230V

460V

575V

208

V23

0V46

0V57

5V 2

08V

230V

460V

575V

460V

575V

460V

575V

460V

575V

460V

575V

460V

575V

460V

575V

Contactors: (04/2013 & Later)

Page 109: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 109

Section G- BlowThru Heat SectionOption 4- Gas Heat Code 04= AHeat Exchangers & Vestibules

200, 250 MBH Furnaces Code 34= 020**, 025**

38

21

22

HeatExchanger

Burner 1

BurnerControlBox 2

Gas Train 3

1

N/S= Not shown on diagram.1 Parts detail follows this section.2 Parts detail follows Burner section.3 Parts detail follows Burner Control Box section.4 Note that Turbulators are NOT furnished with the Heat Exchanger. Turbulator Assemblies must be

ordered separately.

Ref. Part 200/250 Qty. No. Description MBH 1 Heat Exchanger 098320612 1 21 Vestibule 055636358 1 22 Vestibule 055636353 1 38 Capillary Plate 059360301 1 N/S Turbulator Assy. 034150401 4 8

Page 110: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 110

Section G- BlowThru Heat SectionOption 4- Gas Heat Code 04= AHeat Exchangers & Vestibules

320, 400, 500, 640, 650, 790, 800, 1000 MBH FurnacesCode 34= 032**, 040**, 050**, 064**, 065**, 079**, 080**, 100**

21

22

HeatExchanger

Burner 1

BurnerControl

Box 2

Gas Train 3

300

Ref. Part 320/400 500/640 650/790 800/1000 Qty. No. Description MBH MBH MBH MBH 300 Heat Exchanger 098320614 098320616 098320618 098320620 1 21 Vestibule 055636359 055636359 055636359 055636359 1 22 Vestibule 055636354 055636355 055636356 055636357 1 N/S Turbulator 058387201 058387201 058387201 058387201 4

N/S= Not shown on diagram.1 Parts detail follows this section.2 Parts detail follows Burner section.3 Parts detail follows Burner Control Box section.4 Quantity varies depending upon the size of the Heat Exchanger. For 320/400 MBH order 6 pc.; for 500/640 MBH order 9 pc.; for

650/790 MBH order 12 pc.; for 800/1000 MBH order 15 pc. Note that Turbulators are NOT furnished with the Heat Exchanger. Turbulators must be ordered separately.

Page 111: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 111

Section G- BlowThru Heat SectionOption 4- Gas Heat: Code 04= A

Modulating Burner Box, Pilot Valve & Pressure RegulatorCode 34= ****E*, ****R*, ****S*

Diagram

109

113

149102115

147119

125

Burner Control Box

114 112124

116

117

105

145

110

142

143 130144

122

111

106

126120

127118

121

103104

107 108

123

160

161

Pilot Valve/ Pressure Regulator Assy Detail

200, 250, 320 MBH Burners

400- 1000 MBH Burners

160

162

Burner Control

Box

Page 112: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 112

Ref. Part Burner Approval Code Qty. No. Description C07= E* C07= CC, CD ETL- USA Canada 102 Burner Housing 059362302 059362302 1 103 Fan Wheel Housing 035740701 035740701 1 104 Wheel- .5" bore 034861102 034861102 1 105 Motor- .25 HP, 115/60/1 034249200 034249200 1 106 Gun Assembly 200 MBH Furnace 034879901 034879901 1 250 MBH Furnace 034879902 034879902 1 320 MBH Furnace 034879903 034879903 1 400 MBH Furnace 034879904 034879904 1 500 MBH Furnace 034880001 034880001 1 640 MBH Furnace 034880002 034880002 1 650 MBH Furnace 034880002 034880002 1 790 MBH Furnace 034880003 034880003 1 800 MBH Furnace 034880003 034880003 1 1000 MBH Furnace 034880004 034880004 1 107 Inlet Funnel 034743101 034743101 1 108 Fan Guard 034742800 034742800 1 109 Blast Tube 200- 400 MBH Furnace 037378802 037378802 1 500- 650 MBH Furnace 034101703 034101703 1 790- 1000 MBH Furnace 034101707 034101707 1 110 Pilot Mixer 036516401 036516401 1 111 Pilot Assembly 035019600 035019600 1 112 Damper Assembly 035721501 048791401 1 113 Blast Tube Gasket 034102000 034102000 1 114 Right Side Damper 200- 500 MBH Furnace 058594301 058594301 1 640 MBH Furnace 058595201 058595201 1 650- 1000 MBH Furnace 058594501 058594501 1 115 Left Side Damper 200- 640 MBH Furnace 058595001 058595001 1 650- 1000 MBH Furnace 058594401 058594401 1 116 Slide Damper 200 MBH Furnace 058594801 058594811 1 250 MBH Furnace 058594802 058594812 1 320 MBH Furnace 058594803 058594813 1 400 MBH Furnace 058594804 058594814 1 500 MBH Furnace 058594805 058594815 1 640 MBH Furnace 058594806 058594816 1 650 MBH Furnace 058594807 058594817 1 790 MBH Furnace 058594808 058594818 1 800 MBH Furnace 058594809 058594819 1 1000 MBH Furnace 058594810 058594820 1

Section G- BlowThru Heat SectionOption 4- Gas Heat: Code 04= A

Modulating BurnerCode 34= ****E*, ****R*, ****S*

Components

Page 113: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 113

Ref. Part Burner Approval Code Qty. No. Description C07= E* C07= CC, CD ETL- USA Canada 117 Blower Gasket 035019500 035019500 1 118 Burner Cover 033972101 033972101 1 119 Ignition Cable Assembly 1 1 1 120 Glass Cover 036557000 036557000 1 121 Glass Cover Support 036009600 036009600 1 122 Orifice 200 MBH Furnace 058599301 058599301 1 250 MBH Furnace 058599302 058599302 1 320 MBH Furnace 058599303 058599303 1 400 MBH Furnace 059861501 059861501 1 500 MBH Furnace 058599101 058599101 1 640 MBH Furnace 058599102 058599102 1 650 MBH Furnace 058599103 058599103 1 790 MBH Furnace 058599104 058599104 1 800 MBH Furnace 058599104 058599104 1 1000 MBH Furnace 058599201 058599201 1 123 Clip 034919400 034919400 1 124 Flange Bearing 034252000 034252000 2 125 Air Switch Tube 034102801 034102801 1 126 Pilot Burner Tube 200- 400 MBH Furnace 036236000 036236000 1 500- 1000 MBH Furnace 036236100 036236100 1 127 Compression Fitting 034097500 034097500 1 130 Pilot Tube 034102601 034102601 1 142 Manual Cock Valve Not Used 034077300 1 143 Pressure Regulator Valve Not Used 034077600 1 144 90º Compression Elbow Not Used 034097200 1 145 Motor Conduit Box 036558800 036558800 1 147 Torsion Spring Not Used 037528600 1 149 Burner Box Baffle 200- 400 MBH Furnace 058597901 058597901 1 500- 1000 MBH Furnace 058597902 058597902 1 160 Valve- Pressure Regulator 034077600 034077600 1 161 Valve- Manual: 200- 320 MBH 034077300 034077300 1 162 Valve- Solenoid: 400- 1000 MBH 034488400 034488400 1 N/S Flame Rod 036557700 036557700 1 N/S Ignition Electrode Assy. 300032902 300032902 1

Section G- BlowThru Heat SectionOption 4- Gas Heat: Code 04= A

Modulating BurnerCode 34= ****E*, ****R*, ****S*

Components, Continued

N/S= Not shown on diagram.1 Contact Daikin Applied with model and serial number information so that the correct part can be identified.

Page 114: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 114

Section G- BlowThru Heat SectionOption 4- Gas Heat: Code 04= A

Hi Turn Down BurnerCode 34= ****H*, ****T*, ****U*

Diagram

119

328102

109

113

295

300

310318

358

110

106

121120

118

105

117

103

104 107108

358

114

297

322

321

323320

299

144

110

325

324

116

Detail: Orifice, Control Rod, Control Arm, Linkage, Plate Detail

200- 400 MBH

324

500- 1000 MBH

375

145

Page 115: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 115

Burner Approval Code Qty.

Ref. Part C07= E* C07= CC, CD No. Description ETL- USA Canada 102 Burner Housing 059862103 059862103 1 103 Fan Wheel Housing 200- 800 MBH Furnace 096434806 096434806 1 1000 MBH Furnace 059862136 059862136 1 104 Wheel 200- 800 MBH Furnace 034861102 034861102 1 1000 MBH Furnace 034249005 034249005 1 105 Motor 200- 800 MBH Furnace 034249200 034249200 1 1000 MBH Furnace 032248600 032248600 1 106 Gun Assembly 200 MBH Furnace 096414801 N/A 1 250 MBH Furnace 096414802 N/A 1 320 MBH Furnace 096414803 N/A 1 400 MBH Furnace 096414804 096414804 1 500 MBH Furnace 096414805 096414805 1 640 MBH Furnace 096414806 096414806 1 650 MBH Furnace 096414806 096414806 1 790 MBH Furnace 096414808 096414808 1 800 MBH Furnace 096414808 096414808 1 1000 MBH Furnace 096414810 096414810 1 107 Inlet Funnel 200- 800 MBH Furnace 034743101 034743101 1 1000 MBH Furnace 034743102 034743102 1 108 Fan Guard 034742800 034742800 1 109 Blast Tube 200- 400 MBH Furnace 037378802 037378802 1 500 MBH Furnace 034101703 034101703 1 640- 1000 MBH Furnace 034101707 034101707 1

Section G- BlowThru Heat SectionOption 4- Gas Heat: Code 04= A

Hi Turn Down BurnerCode 34= ****H*, ****T*, ****U*

Components

N/A= Not available.

Page 116: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 116

Burner Approval Code Qty.

Ref. Part C07= E* C07= CC, CD No. Description ETL/MEA- USA Canada 110 Orifice Assembly 200 MBH Furnace 096414701 N/A 1 250 MBH Furnace 096414702 N/A 1 320 MBH Furnace 096414703 N/A 1 400 MBH Furnace 096414704 096414724 1 500 MBH Furnace 096414705 096414725 1 640 MBH Furnace 096414706 096414726 1 650 MBH Furnace 096414707 096414727 1 790, 800 MBH Furnace 096414708 096414728 1 1000 MBH Furnace 096414710 096414730 1 113 Gasket- Blast Tube 034102000 034102000 1 114 Air Box Assy 059862112 059862112 1 116 Plate- Actuator Scale 059645001 059645001 1 117 Gasket- Blower 035019500 035019500 1 118 Panel- Burner Box Cover 059388501 059388501 1 119 Ignition Wire Assy 1 1 1 120 Glass Cover- Burner 036557000 036557000 1 121 Support- Glass Cover 036009600 036009600 1 144 Grommet- Flat 060017701 060017701 1 145 Box- Conduit 036558800 036558800 1 295 Motor- Actuator 120V 111047701 2 111047701 2 1 Motor- Actuator 24V 113157801 2 113157801 2 1 297 Control Arm 059862114 059862114 1 299 Control Rod 059861101 059861101 1 300 Crank Arm 059645101 059645101 1 310 Extension- Crank Arm 059862110 059862110 1 318 Bushing- Control Rod 059861301 059861301 1 320 Air Linkage 096414901 096414901 1 321 Air Plate- Adjustable 200 MBH Furnace 096422001 N/A 1 250 MBH Furnace 096421601 N/A 1 320 MBH Furnace 059389601 N/A 1 400 MBH Furnace 096423001 096423101 1 500 MBH Furnace 060086401 096422901 1 640 MBH Furnace 096417701 096417801 1 650 MBH Furnace 096416301 096416301 1 790 MBH Furnace 060097101 060097101 1 800 MBH Furnace 060097101 096422701 1 1000 MBH Furnace 060092401 060097301 1

Section G- BlowThru Heat SectionOption 4- Gas Heat: Code 04= A

Hi Turn Down BurnerCode 34= ****H*, ****T*, ****U*

Components, Continued

N/A= Not available.1 Contact Daikin Applied with model and serial number information so that the correct part can be identified.2 Normally units without controls (Code 12= YM, YC) use a 120V Actuator and units with controls (Code 12= *D, *S,

*E,*F, *W) use a 24V Actuator. Confirm voltage required BEFORE ordering.

Page 117: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 117

Burner Approval Code Qty.

Ref. Part C07= E* C07= CC, CD No. Description ETL/MEA- USA Canada 322 Air Plate- Profile 200, 250 MBH Furnaces 096421501 N/A 1 320 MBH Furnace 059389001 N/A 1 400 MBH Furnace 060097601 060097601 1 500 MBH Furnace 060086101 060086101 1 640 MBH Furnace 096417901 096417901 1 650 MBH Furnace 096415301 096418001 1 790 MBH Furnace 096416501 096416501 1 800 MBH Furnace 060096901 060097001 1 1000 MBH 060092601 060097201 1 323 Plate- Slide Damper 200, 250, 320, 400 MBH Furnaces 059388801 059388801 1 500 MBH Furnace 060086301 060086301 1 640, 650 MBH Furnaces 096417601 096417601 1 790, 800, 1000 MBH Furnaces 060092501 060092501 1 324 Box- Air 200- 400 MBH Furnaces 059869101 059869101 1 500- 1000 MBH Furnaces 060092201 060092201 1 325 Gasket- Air Box 060092301 060092301 1 328 Grommet 000498100 000498100 1 358 Bearing- Sleeve 046761000 046761000 2 375 Grommet- 500- 1000 MBH only 059988700 059988700 1

Section G- BlowThru Heat SectionOption 4- Gas Heat: Code 04= A

Hi Turn Down BurnerCode 34= ****H*, ****T*, ****U*

Components, Continued

N/A= Not available.

Page 118: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 118

FSG Detail

24

34

26

25

39

3130

32

29

GasControl

Box

63

27

4125

61

11

Section G- BlowThru Heat SectionOption 4- Gas Heat: Code 04= A

Modulating Burner Controls Code 34= ****E*, ****R*, ****S*

No Controls (Code 12= YC, YM)Diagram

Page 119: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 119

Ref. Sch. Part Furnace MBH Qty. No. Sym. Description 200/250 320 400- 1000 11 GV1 Pressure Reg. Assy. 061530300 061530300 039742000 1 Valve Only 034077600 034077600 034077600 1 Manual Cock Valve 034077300 034077300 Not Used 1 Solenoid Valve Not Used Not Used 034488400 1 24 Flame Safeguard Subbase 073300702 073300702 073300702 1 25 FSG Flame Safeguard 073300803 073300803 073300803 1 26 Amplifier 073300901 073300901 073300901 1 27 Flame Safeguard T.D. 90 Sec. Modulating Burner/UL Units 073301002 073301002 073301002 1 Flame Safeguard T.D. 30 Sec. Modulating Burner/Canada 073301001 073301001 073301001 1 29 S3 Toggle Switch- 4PST 033536700 033536700 033536700 1 30 IT Ignition Transformer 034482600 034482600 034482600 1 31 Air Switch- Gas Burner 033003800 033003800 033003800 1 32 FLC Fan Limit Control 193423703 1 193423703 1 193423703 1 1 34 TB11 Terminal 349930641 349930641 349930641 20 Terminal Block End Stop 349930841 349930841 349930841 2 Terminal Block End Plate 349930741 349930741 349930741 1 Terminal Block Jumper, 2 Row 349930647 349930647 349930647 1 Terminal Block Jumper, 3P 349930943 349930943 349930943 1 39 Fitting 067297701 067297701 067297701 1 41 Bushing 001242600 001242600 001242600 1 61 R20 Relay (Before 1/10) 061019403 061019403 061019403 1 N/S R20A Relay (After 1/10) 349934764 349934764 349934764 1 N/S Relay Socket 349964702 349964702 349964702 1 63 R23 Pilot Relay (Before 1/10) 019643000 019643000 019643000 1 N/S R23A Pilot Relay (After 1/10, ETL only) 349934764 349934764 349934764 1 N/S Mounting Adapter 349964702 349964702 349964702 1 N/S R23B Pilot Relay (After 1/10) 193454703 193454703 193454703 1 N/S Relay Socket 193454802 193454802 193454802 1

Section G- BlowThru Heat SectionOption 4- Gas Heat: Code 04= A

Modulating Burner Controls Code 34= ****E*, ****R*, ****S*

No Controls (Code 12= YC, YM)Components

N/S= Not Shown on diagram.1 Note that the sensor is NOT sold separately from the controller.

Page 120: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 120

Section G- BlowThru Heat SectionOption 4- Gas Heat: Code 04= A

Modulating Burner Controls (Code 34= ****E*, ****R*, ****S*)MicroTech III Controls (Code 12= *E, *F, *W)

FSG Detail

24

34

2631

30

32

29Gas

ControlBox

61

63

27

25 62

11

GV1 Detail

Panel Detail

FLC

S3

25FSG

IT

TB11

AS

R23B

R23A

R20A

Ref. Sch. Part Furnace MBH Qty. No. Sym. Description 200/250 320 400- 1000 11 GV1 Pressure Reg. Assy. 061530300 061530300 039742000 1 Valve Only 034077600 034077600 034077600 1 Manual Cock Valve 034077300 034077300 Not Used 1 Solenoid Valve Not Used Not Used 034488400 1 24 Flame Safeguard Subbase 073300702 073300702 073300702 1 25 FSG Flame Safeguard 073300803 073300803 073300803 1 26 Amplifier 073300901 073300901 073300901 1 27 Flame Safeguard T.D. 90 Sec. Modulating Burner/UL Units 073301002 073301002 073301002 1 Flame Safeguard T.D. 30 Sec. Modulating Burner/Canada 073301001 073301001 073301001 1 29 S3 Toggle Switch- 4PST 033536700 033536700 033536700 1 30 IT Ignition Transformer 034482600 034482600 034482600 1 31 AS Air Switch- Gas Burner 033003800 033003800 033003800 1 32 FLC Fan Limit Control 193423703 1 193423703 1 193423703 1 1 34 TB11 Terminal Block 349930641 349930641 349930641 18 Terminal Block End Stop 349930841 349930841 349930841 2 Terminal Block End Plate 349930741 349930741 349930741 1 Jumper Terminal 349930942 349930942 349930942 1 61 R20A Relay- High Amp DPDT/120V 349934764 349934764 349934764 1 62 R23A Relay- High Amp DPDT/120V 349934764 349934764 349934764 1 63 R23B Relay- Low Amp DPDT/120V 193424341 193424341 193424341 11 Note that the sensor is NOT sold separately from the controller.

Page 121: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 121

33 42

25

26

23

32

29

22

64

24

63

34 66 65 41 30

39 31

27

R23

R21

TB11

TD10 R22

Section G- BlowThru Heat SectionOption 4- Gas Heat: Code 04= AHi Turn Down Burner ControlsCode 34= ****H*, ****T*, ****U*

No Controls (Code 12= YC, YM)Diagram

Page 122: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 122

Ref. Sch. Part Part Qty. No. Sym. Description Number 22 Support 059388701 1 23 Support 059388601 1 24 Subbase- Flame Safeguard 073300702 1 25 FSG Control- Flame Safeguard 073300803 1 26 Amplifier 073300901 1 27 Time Delay- Flame Safeguard 073301003 1 29 S3 Switch- Toggle 033536700 1 30 IT Transformer- Ignition 034482600 1 31 AS Switch- Air 033003800 1 32 FLC Control- Fan Limit 193423703 1 1 33 LS1/LS2 Switch- Limit 059975301 2 34 TB11 Terminal 349930641 22 Terminal Block End Stop 349930841 2 Terminal Block End Plate 349930741 1 Terminal Block Jumper, 2 Row 349930647 1 Terminal Block Jumper, 3P 349930943 1 39 Fitting 067297701 1 41 Bushing 001242600 1 42 Bushing 049751901 1 N/S R20A Relay 120V 349934764 1 N/S Mounting Adapter 349964702 1 N/S R20B Relay 120V 193454703 1 Relay Socket 193454801 1 63 R23 Relay- 120V/DPDT (Before 03/10) 019643000 1 N/S R23A Relay 120V 349934764 1 N/S Mounting Adapter 349964702 1 N/S R23B Relay- 120VSPST (After 03/10) 193454703 1 Relay Socket 193454801 1 64 R21 Relay- 120V/DPDT (Before 03/10) 019643000 1 64 R21 Relay- 120V/DPDT (After 03/10) 193454703 1 Relay Socket 193454801 1 65 R22 Relay- 120VSPST (Before 03/10) 027400700 1 65 R22 Relay- 120VSPST (After 03/10) 349964764 1 N/S Mounting Adapter 349964702 1 66 TD10 Relay- Time Delay 20.0 Sec. 028210106 1

Section G- BlowThru Heat SectionOption 4- Gas Heat: Code 04= AHi Turn Down Burner ControlsCode 34= ****H*, ****T*, ****U*

No Controls (Code 12= YC, YM)Components

N/S= Not Shown on diagram.1 Note that the sensor is NOT sold separately from the controller.

Page 123: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 123

Section G- BlowThru Heat SectionOption 4- Gas Heat: Code 04= AHi Turn Down Burner Controls Code 34= ****H*, ****T*, ****U*

MicroTech III Controls (Code 12= *E, *F, *W)

FSG Detail

33

25

26

61

32

29

63

Ref. Sch. Part Part Qty. No. Sym. Description Number 24 Subbase- Flame Safeguard 073300702 1 25 FSG Control- Flame Safeguard 073300803 1 26 Amplifier 073300901 1 27 Time Delay- Flame Safeguard 073301002 1 29 S3 Switch- Toggle 033536700 1 30 IT Transformer- Ignition 034482600 1 31 AS Switch- Air 033003800 1 32 FLC Control- Fan Limit 193423703 1 1 33 LS1/LS2 Switch- Limit 059975301 2 34 TB11 Terminal 349930641 18 Terminal Block End Stop 349930841 2 Terminal Block End Plate 349930741 1 Terminal Block Jumper 349930942 1 61 R20A Relay-High Amp DPDT/120V 349934764 1 62 R20B Relay- Low Amp DPDT/120V 193424341 1 63 R21 Relay- Low Amp DPDT/120V 193424341 1

24

34

62

30

31

27

R21

R20A

TB11

R20B

LS1LS2

IT

FLC

S3

AS

LS1, 2

FSG

1 Note that the sensor is NOT sold separately from the controller.

Page 124: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 124

Section G- BlowThru Heat SectionOption 4- Gas Heat: Code 04= A

Modulating Burner Code 34= ****E*, ****R*, ****S*

Gas Train Inlet

226

Units without Pressure Regulator Valve: Code 34= ****E*

Units with Pressure Regulator Valve: Code 34= ****R*, ****S*

228234 228

234

228

234200, 250, 320 MBH Furnaces

400, 500, 640 MBH Furnaces

650, 790, 800, 1000 MBH Furnaces

Ref. Part Part Qty. No. Description Number 226 Gas Valve 200, 250, 320 MBH 910144815 1 400, 500 MBH 910144816 1 640- 1000 MBH 910144817 1

Ref. Part Pressure Regulator Qty. No. Description Code 34= ****R* Code 34= ****S* 205 Shutoff Valve 400- 1000 MBH 034077300 034077300 1 228 Pressure Regulator 200, 250, 320 MBH 034078302 034078302 1 400 MBH 036619915 036619916 1 500 MBH 036619914 036619915 1 640, 650 MBH 036619923 036619925 1 790, 800 MBH 036619922 036619924 1 1000 MBH 073387201 036619923 1 234 Gas Valve 200, 250, 320 MBH 073387401 073387401 1 400, 500 MBH 073387402 073387402 1 640- 1000 MBH 073387403 073387403 1

Page 125: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 125

Section G- BlowThru Heat SectionOption 4- Gas Heat: Code 04= A

Hi Turn Down Burner Code 34= ****H*, ****T*, ****U*

Gas Train Inlet

226

Units without Pressure Regulator Valve: Code 34= ****H*

Units with Pressure Regulator Valve: Code 34= ****T*, ****U*

226

232

ETL USA UnitsCode 07= E*

(also Canada 200- 320 MBH )

Canada UnitsCode 07= C*

(except 200- 320 MBH)

226

232

Canada UnitsCode 07= C*

Pilot Valve Detail

292

Back Wall of Vestibule

Ref. Part Part Qty. No. Description Number 226 Gas Valve 200, 250, 320 MBH 910144815 1 400, 500 MBH 910144816 1 640- 1000 MBH 910144817 1

Ref. Part Pressure Regulator Qty. No. Description Code 34= ****T* Code 34= ****U* 226 Shutoff Valve 200, 250, 320 MBH 073387401 073387401 1 400 MBH 073387402 073387402 1 640- 1000 MBH 073387403 073387403 1 232 Pressure Regulator 200, 250, 320 MBH 034078302 034078302 1 400 MBH 036619915 036619916 1 500 MBH 036619914 036619915 1 640, 650 MBH 036619923 036619925 1 790, 800 MBH 036619922 036619924 1 1000 MBH 073387201 073387403 1 292 Valve- Combination 073336504 073336504 1

Page 126: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 126

Section G- BlowThru Heat SectionOption 4- Gas Heat: Code 04= A

Modulating BurnerCode 34=****E*, ****R*, ****S*Gas Train Controls GV2, GV3

255

400- 1000 MBH Furnaces

Canada Approved (Code 07= C*)

750

256

248

255750

256

248 248

253

GV2

GV2 GV3

GV2

750249

248

253

400- 1000 MBH Furnaces

ETL- USA Approved (Code 07= E*)

200- 320 MBH Furnaces

Ref. Part Part Qty. No. Description Number 248 Gas Valve- GV2 073336502 1 255 Junction Box 020766100 1 256 Junction Box Cover 000127300 1 750 Gas Pipe 034252800 1

Gas Controls: 200, 250, 320 MBH Furnace

Ref. Part Part Qty. No. Description Number 248 Gas Valve- GV2, GV3 400, 500 MBH 073387801 2 640- 1000 MBH 073387802 2 253 Pressure Regulator 400, 500 MBH 034078100 1 640- 1000 MBH 034077804 1 255 Junction Box 020766100 1 256 Junction Box Cover 000127300 1 750 Gas Pipe 400, 500 MBH 031597535 1 640- 1000 MBH 036617700 1

Gas Controls: 400- 1000 MBH Furnace ETL Approved

Ref. Part Part Qty. No. Description Number 248 Gas Valve Body- GV2 400, 500 MBH 041768902 1 640- 1000 MBH 041768903 1 249 Actuator 034490100 1 253 Pressure Regulator 400, 500 MBH 034078100 1 640- 1000 MBH 034077804 1 750 Gas Pipe 400, 500 MBH 031597535 1 640- 800 MBH 036617800 1 1000 MBH 000868600 1

Gas Controls: 400- 1000 MBH Furnace Canada Approved

Page 127: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 127

Section G- BlowThru Heat SectionOption 4- Gas Heat: Code 04= A

Hi Turn Down Burner Code 34= ****H*, ****T*, ****U*

Gas Train Controls GV1, GV2, GV4, GV5, GV6

790- 1000 MBH Furnaces

Canada Approved (C07= CC, CD)

254

262

263

254

GV2

246

400- 650 MBH Furnaces

UL Approved (C07= EU, EF, EI)

200- 320 MBH Furnaces

Ref. Part Part Qty. No. Description Number 254 Gas Valve- GV2 073336504 1 N/S Junction Box 020766100 1 N/S Junction Box Cover 000127300 1

Gas Controls: 200, 250, 320 MBH Furnace

Ref. Part Part Qty. No. Description Number 254 Gas Valve- GV1, GV4 400- 650 MBH 073336504 2 Gas Valve- GV1,GV4,GV5 790- 1000 MBH 073336504 3 262 Junction Box 020766100 1 263 Junction Box Cover 000127300 1

Gas Controls: 400- 1000 MBH FurnaceUL Approved

Ref. Part Part Qty. No. Description Number 246 Gas Valve Body- GV2 400, 500 MBH 041768902 1 640- 1000 MBH 041768903 1 247 Actuator- GV2 111047401 1 254 Gas Valve- GV4, GV5 400- 650 MBH 073336504 2 Gas Valve- GV4,GV5,GV6 790- 1000 MBH 073336504 3

Gas Controls: 400- 1000 MBH FurnaceCanada Approved

N/S= Not shown on diagram.

GV4GV1

262263

254GV4

GV1

GV5

790- 1000 MBH Furnaces

UL Approved (C07= EU, EF, EI)

400- 650 MBH Furnaces

Canada Approved (C07= CC, CD)

254 GV5GV4

GV6

GV2

247

246

GV5GV4

254

247GV2

Page 128: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 128

Section G- BlowThru Heat SectionOption 4- Gas Heat: Code 04= A

Gas Train Outlet

275

283320- 1000 MBH

277

275

283200, 250 MBH 277

Actuator & Linkage- See next page

275 275

Hi Turn Down BurnersCode 34= ****H*, ****T*, ****U*

Modulating BurnersCode 34= ****E*, ****R*, ****S*

200- 320 MBH 400- 1000 MBH

Actuator & Linkage- See next page

Ref. Part Part Qty. No. Description Number 275 Pipe w/ Valve Mount 200- 320 MBH 035019700 1 400 MBH 046674500 1 500 MBH 035019800 1 640- 1000 MBH 036235500 1 277 Butterfly Valve 200- 320 MBH 034488302 1 400, 500 MBH 034488303 1 640- 1000 MBH 034488304 1 283 Shutoff Valve

200- 320 MBH 910144815 1 400, 500 MBH 910144816 1 640- 800 MBH 910144817 1 1000 MBH UL 910144818 1 1000 MBH Canada 910144817 1

Ref. Part Part Qty. No. Description Number 275 Gas Valve 200- 320 MBH 910144815 1 400, 500 MBH 910144816 1 640- 800 MBH 910144817 1

Page 129: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 129

Ref. Part Furnace MBH= Qty. No. Description 200- 320 400 500- 650 790- 1000 295 Actuator Motor- VM1 Units w/ MicroTech III Controls USA Units 113157801 113157801 113157801 113157801 1 Canada Units 113157801 0916880022 0916880022 0916880022 1 Units w/ No Temp. Ctl. (Code 12= YC) All Units Before 1/10 0634834221 0634834221 0634834221 0634834221 1 All Units After 1/10 113157801 113157801 113157801 113157801 1 Units w/ No Temp. Ctl. (Code 12= YM) UL Units 111047701 111047701 111047701 111047701 1 Canada Units 111047701 0916880013 0916880013 0916880013 1 297 Crank Arm 034250600 034250600 034250600 034250600 1 298 Ball Joint 034250500 034250500 034250500 034250500 2 299 Linkage Arm 058598401 058598401 058598401 058598401 1 300 Crank Arm 023463200 023463200 023463200 023463200 1 301 Extension Arm (Canada Units Only) Not Used 098735201 098735201 098735201 1 310 Air Damper Lever Arm 058598101 058598101 059365001 058598101 1 311 Gas Valve Arm 058598601 058598601 058598601 058598601 1

Section G- BlowThru Heat SectionOption 4- Gas Heat: Code 04= A

Gas Train- Damper LinkageModulating Burners / VM1 Actuator

Code 34= ****E*, ****R*, ****S*

297

Burner Box

295

311

298

300

310

299

Butterfly Valve (see previous page)

1 Assembly part number. Motor only is p/n 113105101, and Interface Kit only is p/n 067112501.2 Assembly part number. Motor only is p/n 113157801, and Switch Kit only is p/n 060009101.3 Assembly part number. Motor only is p/n 111047701, and Switch Kit only is p/n 060009101.

UL Units/Canada Units (200- 320 MBH)

Canada Units (400- 1000 MBH)

297

Burner Box

295

311

298

300

310

299

Butterfly Valve (see previous page)

301

Canada Actuator Detail

VM1Actuator

Switch KitTransformer

Page 130: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 130

Section G- BlowThru Heat SectionOption 4- Gas Heat w/ 200 MBH and 250 MBH Furnace

Code 04= A AND Code 34= 020***, 025***Cabinet Doors, Hardware, and Flue Box Mounting

649

664665

650

664

665

658

Ref. Part Part Qty. No. Description Number 649 Door Assembly 098346924 1 650 Door Assembly 098346930 1 N/S Flue Box Front 111009902 1 658 Flue Box Back 403398101 1 661 Flue Box Mount 403399301 1 664 Sleeve Bearing 047138507 4 665 Door Catch 055502602 4 667 Gasket 055921418 2 668 Gasket 055921420 2 N/S Hinge 060055101 2N/S= Not Shown on diagram.

668

668

667

667

Page 131: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 131

Section G- BlowThru Heat SectionOption 4- Gas Heat w/ 320 MBH thru 1000 MBH Furnace

Code 04= A AND Code 34= 032***,040***,050***,064***,065***,079***,080***, 100***

Cabinet Doors, Gasketing, Hardware & Flue Box Mounting

Ref. Part Part Qty. No. Description Number 650 Door Assembly 320, 400 MBH 098346931 1 500, 640 MBH 098346932 1 650, 790 MBH 098346933 1 800, 1000 MBH 098346934 1 652 Inspection Door 034095801 1 658 Back- Flue Box 320, 400 MBH 403398001 1 500, 640 MBH 403398401 1 650, 790 MBH 403398601 1 800, 1000 MBH 403398801 1 661 Angle- Flue Box 320, 400 MBH 403399401 1 500, 640 MBH 403399501 1 650, 790 MBH 403399601 1 800, 1000 MBH 403399701 1 663 Drip Shield 033487300 1 664 Sleeve Bearing 047138507 2 665 Door Catch 055502602 2 667 Gasket 055921418 2 668 Gasket 055921420 2 669 Gasket 031949200 1 N/S Hinge 034005900 2

650

664665 667

661

658

668669

663

652

N/S= Not Shown on diagram.

Page 132: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 132

Cabinet Door Gasketing and Hardware➩

Section H- BlowThru Heat Blank Access SectionNotes

Primary Codes that pertain: 38, Additional Codes that pertain: 34, 06

Code 38 determines all of the section characteristics. If Code 38= A the section is 22", if Code 38= B the section is 40", if Code 38= D, the section is 52". If Code 39= Y, there is no section.

Code 34 determines the BlowThru Heat Section (Section G). If Code 34= BBBBBB then there is a 40" Blank/Empty section. There has to be a Section G in order for there to be a Section H, therefore Code 34 cannot = YYYYYY.

Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the BlowThru Heat Blank/Empty Section, contact Daikin Applied to ensure correct liners, insulation and hardware are ordered.

Ref. Part Part Number Qty. No. Description N/S Sleeve Bearing 047138507 4 N/S Door Catch 055502602 4 N/S Gasket 048165901 1

N/S= Not Shown on diagram.1 This part is ordered by the foot. Order as many feet as needed.

Access Door Latching Assemblies, Key, & Lock (All Sections) 2

Ref. Part Part Qty. No. Description Number 01 Door Latching Assy.- LH, 55" Section 111242201 var. 02 Door Latching Assy.- RH, 55" Section 111242202 var. 01 Door Latching Assy.- LH, 73" Section 111242211 var. 02 Door Latching Assy.- RH, 73" Section 111242212 var. N/S Access Door Key 021993200 var. N/S Access Door Lock 112031701 var.

Door Latching Assy.Left Hand

Door Latching Assy.Right Hand

N/S= Not Shown on diagram.2 These Door Latching Assemblies are used on Standard Unit Section Access Doors.

When replacing a Latch Assembly, first determine the handing of the door. Door handing is dependent upon the door's location on the unit. For Handing identification, refer to the drawings below. If unable to determine the hand of the door, contact Daikin Applied with model and serial information AND the location of the door. Once the door handing is determined, it is then necessary to determine the height of the section. The 55" Latching Assembly is used for unit sections 55 inches high (most sections) and the 73" assembly is used for 73" high sections (eg. Section A2 Energy Recovery [Code 20= *E]).

01 02

Page 133: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 133

Section I- BlowThru Cooling SectionNotes

Primary Codes that pertain: 35, 36Additional Codes that pertain: 06

Code 35 determines the section characteristics. If Code 35= YYYY, then there is no section. If the first three digits of Code 35= CYY then this is a cooling unit. If the first three digits of Code 35= DYY then the section contains only a Drain Pan in a 40" section. If the first three digits of Code 35= GYY then the unit is cooling only with Hot Gas Reheat. If the fourth digit of Code 35= S, the Drain Pan is stainless steel; P, Y in the fourth position indicates that the pan is galvanized steel. If the fourth digit is L, the Drain Pan is wider than standard and made from stainless steel. If the fourth digit of Code 35= T, then the Drain Pan is wider than standard and made from painted galvanized steel. If the fourth digit of Code 35= L, T the first three digits of Code 35 must equal DYY.

Code 36 determines the Cooling Coil's characteristics.

Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the BlowThru Cooling section, contact Daikin Applied with model and serial number information to ensure correct liners, insulation and hardware are ordered. For standard Access Door Latching Assemblies, see Section H.

Ref. Part Part Number Qty. No. Description N/S Sleeve Bearing 047138507 4 N/S Door Catch 055502602 4 N/S Gasket 048165901 1

Cabinet Door Gasketing and Hardware

N/S= Not Shown on diagram.1 This part is ordered by the foot. Order as many feet as needed.

Page 134: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 134

Section I- BlowThru Cooling SectionEvaporator Coil, Gasket and Drain Pans

Code 35= CYYP, CYYS, CYYY AND Code 36= 5Z****, 4Z****Unit Sizes 035- 042D 1

Unit Base

3

39

13

14

Drain PansCode 27= DYYY, DYYS- 40" Section- Unit Sizes 035- 042D

Diagram and Components

Ref. Part Code Part Qty. No. Description 35= Number 3 Coil- refer to the following page 13 Drain Pan- Auxiliary 404042001 1 14 Drain Pan- Main Galvanized CYYY, CYYP 056280472 1 Stainless Steel CYYS 056280422 1 39 Gasket 049263200 5 ft.

Ref. Part Drain Pan Material Code 27= Qty. No. Description DYYY- Galvanized DYYS- Stainless 103 Drain Pan 056280471 056280421 1

103Unit Base

1 For Drain Pans and components when Code 35= GYY* and/or Code 35 Digit 4= L, T, use the Distributor Tools BOM Search function on the Daikin Parts website or contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified.

Page 135: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 135

Section I- BlowThru Cooling SectionEvaporator Coils 1

Unit Sizes 035- 042D

Typical CoilDescription

4Z 08 3 D

Coil Model

Fins-per-inch08= 8 FPI10= 10 FPI12= 12 FPI14= 14 FPI

Rows3= 3 Row Coil4= 4 Row Coil5= 5 Row Coil6= 6 Row Coil

Fin StockC= Hi-F Copper Fin (stainless casing)D= Lanced Aluminum Fin (galv. casing)

1 Evaporator Coils are serial number specific. Contact Daikin Applied with complete model and serial number information in order to ensure that the correct coil is identified.

Page 136: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 136

Section J- Final Filter SectionNotes

Primary Codes that pertain: 39Additional Codes that pertain: 04, 33 (Mid 2012 & Later), 34

Code 39 determines section characteristics. If Code 39= A, B, E, F, G, H there are filters; if C, D then there is a Blank/Empty Section. If Code 39= Y, there is no section.

Codes 04 and 34 determine what type of heat the unit uses. The type of heat influences the filter media and associated parts.

Code 33 (Mid 2012 & Later) indicates the presence of Magnehelic/Differential Pressure Gauges. See Section B (Filter Section) for Gauge part number and description.

Ref. Part Part Number Qty. No. Description N/S Sleeve Bearing 047138507 4 N/S Door Catch 055502602 4 N/S Gasket 048165901 1

Cabinet Door Gasketing and Hardware (Applies to Filter OR Blank/Empty Section)

N/S= Not Shown on diagram.1 This part is ordered by the foot. Order as many feet as needed.

Section Mounted ControlsHL23 Gas Hi Limit Control: Code 04= A AND Code 39 DOES NOT= Y

PC6 Clogged Filter Control: Code 39 DOES NOT= Y, C, D

390

388 389 385

387

386

Unit AirFlow

Ref. Part Part Qty. No. Description Number 385 J Clamp- Antirotate 065779801 1 386 Stat Support 058379401 1 387 HL23 Firestat 047938804 1 388 Junction Box 020766100 1 389 Junction Box Cover 000127300 1 390 Nipple 251815901 1

Control HL23 Gas Heat Hi-Limit (Firestat)

Gas Hi Limit ControlClogged Filter Pressure Switch- PC6

Clogged Filter Control

Ref. Part Part Qty. No. Description Number 345 PC6 Pressure Ctl. 065493801 1

345

Supplied with PC6 Harness from Main/Split Box

Page 137: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 137

Section J- Final Filter SectionFilter Frame, Filter Gaskets, Filters

Code 39= A, B, E, F 1

200

20

2

5A

4AUnit Base

Access Door

Ref. Part Type of Heat Qty. No. Description C39= C04= A, E C04= W, Y 2 Filter Frame 058403111 058403111 1 200 Filter Assy. w/ Gasket- 24 x 24 x 12" Standard A, B 056193206 056193202 4 With intersept F N/A 066302252 4 4A Gasket 073337024 021768924 4 250 Filter Assy. w/ Gasket- 12 x 24 x 12" Standard A, B 056193205 056193201 4 With intersept F N/A 066302253 4 5A Gasket 073337012 021768912 4 20 Gasket- Door 026172843 026172804 2

250

1 If Code 39= G, H use the Distributor Tools BOM Search function on the Daikin Parts website or contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified.

20

Page 138: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 138

Section K- Discharge Plenum SectionNotes

Primary Codes that pertain: 40Additional Codes that pertain: 06, 11, 15, 34, 35, 36, 38, 39, 41

Code 40 determines the discharge direction. Normally RPS units have bottom discharge (Code= B*) or side discharge (Code= SY). Normally RFS units have bottom (Code= B*), side (Code= SY), or front discharge (Code= FY). The VAV Damper option is Code *E.

Code 06, insulation and liners, influences the front panels part numbers. Code 11, the Disconnect Switch option, influences access doors part numbers. For sheet metal components that make up the Discharge Plenum Section, contact Daikin Applied with model and serial number information to ensure correct liners, insulation and hardware are ordered. For standard Access Door Latching Assemblies, see Section H.

Codes 34- 39, the BlowThru/Final Filter section codes, and Code 41, the special Blank/Empty Section code, pertain to some of the final assembly part numbers. If Code 41=Y (no blank access compartment), then the discharge plenum end panels are painted. If a Blank/Empty Section is present, then the end panels are unpainted.

Note: RPS and RFS Main Control Boxes are usually located in this section. However, Main Control Box components are listed in Section N.

Ref. Part Part Qty. No. Description Number 50 Smoke Detector 098873101 1 51 Sampling Tube Standard Discharge 098872901 1 Side/Top Discharge 098873501 2

Smoke Detector- SD1

Section Mounted ControlsOAT, DAT, SD1

Ref. Part Part Qty. No. Description Number 7 DA Temp. Sensor 193414602 1 7A Bracket 055732401 1

Discharge Air Temperature Sensor- DAT

8

7A7

Main Control Box

DA Opening

8A

Ref. Part Part Qty. No. Description Number 8 OA Temp. Sensor 193414602 1 8A Bracket 111075901 1

Outside Air Temperature Sensor- OAT

50

51

Main Control

Box

Page 139: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 139

Section K- Discharge Plenum SectionDamper Assembly- w/ Actuator ACT5

Code 40= BE

Ref. Part Part Qty. No. Description Number 130 Damper Assembly 20 x 76" w/ Act. 403716312 1 3 Motor Mount 055921201 1 4 Damper Blade 059404314 4 18 Damper Linkage 055536606 1 20 Actuator Motor- ACT5 113144901 1 21 Damper Shaft 403717101 1 22 Damper Ball Joint 000887000 2 24 Damper Blade Gasket 030051979 1 25 Support 403716801 1 26 Retainer 403717301 1 27 Bearing, sleeve flange 047138504 1

4

3

20

25

130

20

18

21

22

22

21

2624

27

Page 140: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 140

Section L- Out-of-Airstream Blank/Empty SectionNotes

Codes that pertain: 41Additional Codes that pertain: 06

If Code 41= 2 there is a 40" Out-Of-Airstream Blank/Empty section. If Code 41= Y, there is no Out-of-Airstream Blank/Empty Section.

Code 06, insulation and liners, influences the front panels part numbers. For sheet metal components that make up the Out-of-Airstream Blank/Empty Section, contact Daikin Applied with model and serial number information to ensure correct liners, insulation and hardware are ordered. For sheet metal components that make up the Out-Of-Airstream Blank/Empty Section, contact Daikin Applied to ensure correct liners, insulation and hardware are ordered. For standard Access Door Latching Assemblies, see Section H.

Ref. Part Part Number Qty. No. Description N/S Sleeve Bearing 047138507 4 N/S Door Catch 055502602 4 N/S Gasket 048165901 1

Cabinet Door Gasketing and Hardware (Applies to Filter AND Blank/Empty Section)

N/S= Not Shown on diagram.1 This part is ordered by the foot. Order as many feet as needed.

LT20- Blank Access Section Light/S20- Blank Access Section Light Switch/REC20- Blank Access Section Receptacle284 285

288 289

Section Mounted ControlsLT20, REC20, S20- Section Mounted Light

Ref. Part Part Qty. No. Description Number 284 Light Fixture 6/13 & Earlier 042229500 1 Light Fixture 7/13 & Later 910145007 1 285 Bulb- LT20 065492402 1 288 Light Switch- S20 065492201 1 289 Receptacle- REC20 030187000 1

Page 141: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 141

Section M- Condenser SectionNotes

Primary Codes that pertain: 09, 12, 43, 44, 47, 54, 68Additional Codes that pertain: 17, 18, 42, 45

This section houses the Compressors, Condenser Coils, Condenser Control Box (RCS units only), Pressure Controls, and Fan Deck.

The Compressor high and low pressure controls as well as the fan pressure controls are always located in this section. RCS units have the Pressure Controls mounted on the Condenser Control Box Manifold. SpeedTrol Inverters and Line Reactors are also in the Condenser Control Box. RPS units have the Pressure Controls as well as SpeedTrol Inverters and Line Reactors (if supplied) in a box mounted where the air handler and condensing unit attach.

Code 09, unit voltage, affects Compressor Contactors and Motor Protectors (located in the Condenser Control Box for RCS units) as well as the Compressor selection.

Code 12 determines whether there is a MicroTech III Unit Controller present or if the unit is not provided with a factory installed controller.

Code 43 determines if the Micro Channel Condenser Coils are coated or not, and if the unit is equipped with Coil/Vandal Guards AND/OR Sealtite conduits.

Code 44 shows the type of compressor selected. Code 44= R NORMALLY stands for units with ALL standard scroll compressors. For units with Inverter Compressors (Code 44= V, W) refer to form 7000512. (Starting 04/15 ALL 016D and 031D units have been converted to use Inverter Compressors ONLY.) Starting in late 2014, some units are built as specials with Digital Scroll Compressors with Code 44= R AND Code 60= XX with Digital Scroll Compressors listed as a special feature (refer to the drawing below for an example of Special Code String Text). Confirm the presence of a Digital Scroll Compressor BEFORE ordering to ensure that the correct part(s) are identified. Code 44= D also indicates the presence of digital compressors.

Page 142: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 142

Section M- Condenser SectionNotes, Continued

Code 47 determines Condenser Fan operation: FanTrol [Standard operation] (Code 47= 1), or SpeedTrol [Low Ambient operation] (Code 47= 2). If Code 47= 3, the unit is equipped with optional Quiet Fan assemblies and FanTrol. If Code 47= 4, the unit is equipped with optional Quiet Fan assemblies and SpeedTrol. If Code 47= 5, the unit is equipped with optional TEAO Fan Motors and FanTrol. If Code 47= 6, the unit is equipped with optional TEAO Fan Motors and SpeedTrol. Note that some units were built as specials with Code 50 OR Code 60= XX with 1.5HP TEAO motors listed as a special feature. Confirm the presence of TEAO motors BEFORE ordering. Use the Distributor Tools BOM Search function on the Daikin Parts website or contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified.

Code 54 indicates if Modulating Hot Gas Reheat (MHGR) was chosen. This option alters the number of Variable Speed Condenser motors and Condenser Fan circuiting in the Main Control Box.

Code 68 specifies the SCCR or “Short Circuit Current Rating” for the unit. Standard units are always rated at “10 SCCR” (Code 68= 10, OR no entry). An entry with any other value (Eg: Code 68= 22, 65 OR indicated in the specials description in the Code String lookup) may change disconnect switches, circuit breakers, fuses, and other miscellaneous components. When Main Control box parts are required for units with nonstandard SCCR ratings, use the Distributor Tools BOM Search function on the Daikin Parts website or contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified.

Code 17 determines whether the RCS control box has Ground Fault and/or Phase Failure capability.

Code 18 determines if there is a unit powered Receptacle, and associated controls.

Code 42 indicates Compressor capacity control.

Code 45 determines the way the Compressor is mounted. If Code 45= Y the unit must be an RFS.

The Condenser Coil Compartment, and the Compressor Compartment components are different for RPS and RCS units. All other aspects of the section (Fan Deck, Compressors, etc.) are identical. The Condenser Section is integral to the RPS unit, but is not used on the RFS.

An RCS unit is a condensing unit only. RCS units can either be used as a Stand Alone Condenser unit, or used in conjunction with an RFS. For information specific to RCS Standalone Units (RCS015- 040D units when Code 12= *A), refer to RPL form 7000197.

NOTE: This form is to be used for RCS units when Code 12= DOES NOT= *A. For RCS015- 040D units when Code 12= *A refer to form # 7000197.

Page 143: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 143

Section M- Condenser SectionFan Deck, Coil Guard Diagrams

Unit Sizes 015- 026D

Standard Fan Deck

105

Coil Guards 1

(Code 43= *G)

1 Typical. RPS unit shown.

106

101

015, 020, 025D Fan Deck Detail

Fan # 12

Fan # 11

End of Unit

Fan Layout Detail

A

016, 021, 026D Fan Deck Detail

Fan # 12

Fan # 11

End of Unit

End of Unit

015, 020, 025D Fan Deck shown

End of Unit

Page 144: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 144

CDF150

CDF160

CDF153

MO

TOR

GN

DW

IRE

CDF151

Fan # 12Fan # 11

Fan # 22Fan # 21

Section M- Condenser SectionFan Deck, Coil Guard Diagrams

Unit Sizes 030- 042D

Standard Fan Deck

030, 031, 035, 040, 042D Fan Deck Detail

55

End of Unit

105

Coil Guards 1

(Code 43= *G)

1 Typical. RPS unit shown.

106

101

Fan Layout Detail

End of Unit

Page 145: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 145

Unit Size Ref. Part Part 015 016/ 025 026 030 035 040 042 No. Description Number 020 021 031 55 Panel, Blank 258933501 NA 5 NA 5 2 2 2 2 101 Fan Deck Panel 258929501 2 2 2 2 4 4 4 4 Condenser Motor 208/230/460V 111 1.0 HP, Std. Mtr. Code 47= 1, 2 500552601 1 2 2 2 2 4 4 4 4 1.5 HP, TEAO Code 47= 5 112060001 2 2 2 2 2 4 4 4 4 1.5 HP, TEAO Code 47= 6 112060002 2 2 2 2 2 4 4 4 4 Condenser Motor 575V 111 1.5 HP, Std. Mtr. Code 47= 1, 2 046744203 2 2 2 2 4 4 4 4 1.5 HP, TEAO Code 47= 5, 6 112060007 2 2 2 2 2 4 4 4 4 113 Condenser Fan Motor Mount 098667802 3 4 4 4 4 8 8 8 8 112 Condenser Fan Prop 258981901 2 2 2 2 4 4 4 4 150 Condenser Fan Guard 098668302 2 2 2 2 4 4 4 4

Section M- Condenser SectionStandard Condenser Fan Components

Code 47= 1, 2, 5, 6

1 The original FanTrol only motor (Code 47= 1) is obsolete and no longer available. Use inverter duty motor 500552601 for ALL applications when Code 47= 1 OR 2.

2 This 1.5HP TEAO (Totally Enclosed Air Over) Condenser Motor MAY have been specified as a special with Code 50= XX Mid 2012 & Earlier, OR Code 60= XX Mid 2012 & Later with TEAO motors listed as a special feature. In addition, Code 47= 5 indicates that the unit is equipped with TEAO motors and Fantrol AND Code 47= 6 indicates that the unit is equipped with TEAO motors and Speedtrol. If unsure as to which motor was installed, use the Distributor Tools BOM Search function on the Daikin Parts website or contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified.

3 This is only one of two pieces that make up the Motor mount. For a complete Motor Mount, order a quantity of TWO per Motor. Quantity listed is the TOTAL for the unit.

150112

111

113

101

Page 146: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 146

Section M- Condenser SectionQuiet Fan Assembly

Code 47= 3, 4

Unit Size Ref. Part Part 015 016 025 026 030 035 040 042 No. Description Number 020 021 031 1 Quiet Fan Assembly 1

208V 500526602 2 2 2 2 4 4 4 4 230V 500526603 2 2 2 2 4 4 4 4 460V 500526604 2 2 2 2 4 4 4 4 575V 500526605 2 2 2 2 4 4 4 4 55 Panel, Blank 258933501 NA 5 NA 5 2 2 2 2.1 Quiet Fan Assemblies are sold as assemblies ONLY. Individual components including the Motor, Fan Prop, Fan Guard, Motor Mount,

and Fan Top Panel are NOT available separately.

11

Page 147: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 147

Section M- Condenser Section Compressors Circuit #1: Code 44= R OR D 3

Unit Size 015 020 025 030 035 040 042 016 2 021 026 031 2

Ref. Part No. Number 1 113090101 1 113090102 1 113090104 1 1 113091101 5/15 & Earlier 1 500597501 6/15 & Later 1 113091102 9/14 & Earlier 1 1 500597502 7/15 & Later 1 1 113091104 6/15 & Earlier 1 1 500597504 10/15 & Later 1 1 1 113091301 1 113091302 1 113091304 1 1 113091901 1 113091902 1 113091904 1 RPS Units only 1 113094601(T) 11/10 & Earlier 1 113090401 12/10 thru 6/15 2 500597901(T) 7/15 & Later 1 113094602(T) 10/10 & Earlier 1 113090402 11/10 thru 6/15 2 500597902 (T) 7/15 & Later 1 113094604(T) 11/10 & Earlier 1 113090404 12/10 thru 6/15 2 500597904(T) 7/15 & Later 1 RCS Units only 1 113094601(T) 11/10 & Earlier 1 113090401 12/10 & Later 2 113094602(T) 10/10 & Earlier 1 113090402 11/10 & Later 2 113094604(T) 11/10 & Earlier 1 113090404 12/10 thru 6/15 2

Standard AND Digital Scroll Compressor Units: Circuit #1 3

208/

230V

460V

575V

208/

230V

460V

575V

208/

230V

460V

575V

208/

230V

460V

575V

208/

230V

460V

575V

208/

230V

460V

575V

208/

230V

460V

575V

(T)= Tandem compressor assembly.1 For units built during the transition, use the Distributor Tools BOM Search function on the Daikin Parts website or contact Daikin

Applied with model and serial number information to ensure that the correct part(s) are identified. Note that these compressors are NOT drop in substitutions for each other because the piping connections are NOT in the same location.

2 Starting 04/15 ALL 016D, 031D units have been converted to use Inverter Compressors ONLY. For Inverter Compressor units (Code 44= V, W) refer to form 7000512.

3 Note that there are some Digital Scroll Compressor units built as SPECIALS with Code 44= R AND Code 60= XX WITH DIGITAL SCROLL COMPRESSORS listed as a special feature (refer to the Notes page at the beginning of the Condenser OR Control Box Section [Section N] for more information). It is important to note that CIRCUIT # 1 COMPRESSORS ARE ALWAYS STANDARD SCROLLS.

Page 148: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 148

Section M- Condenser Section Compressors Circuit #1: Code 44= R OR D, Continued 2

Unit Size 015 020 025 030 035 040 042 016 1 021 026 031 1

Ref. Part No. Number

Standard AND Digital Scroll Compressor Units: Circuit #1 2

208/

230V

460V

575V

208/

230V

460V

575V

208/

230V

460V

575V

208/

230V

460V

575V

208/

230V

460V

575V

208/

230V

460V

575V

208/

230V

460V

575V

RPS Units only 1 113094901(T) 11/10 & Earlier 1 113090701 12/10 & Later 2 113094902(T) 09/10 & Earlier 1 113090702 10/10 & Later 2 113090704 2 RCS Units only 1 113094901(T) 11/10 & Earlier 1 113090701 12/10 & Later 2 113094902(T) 09/10 & Earlier 1 113090702 10/10 & Later 2 113094904(T) 11/10 & Earlier 1 113090704 12/10 & Later 2 1 113094901(T) 10/10 & Earlier 1 113090701 10/10 & Later 2 113094902(T) 11/10 & Earlier 1 113090702 12/10 & Later 2 113094904(T) 9/10 & Earlier 1 113090704 10/10 & Later 2(T)= Tandem compressor assembly.1 Starting 04/15 ALL 016D, 031D units have been converted to use Inverter Compressors ONLY. For Inverter Compressor units (Code

44= V, W) refer to form 7000512.2 Note that there are some Digital Scroll Compressor units built as SPECIALS with Code 44= R AND Code 60= XX WITH DIGITAL

SCROLL COMPRESSORS listed as a special feature (refer to the Notes page at the beginning of the Condenser OR Control Box Section [Section N] for more information). It is important to note that CIRCUIT # 1 COMPRESSORS ARE ALWAYS STANDARD SCROLLS.

Page 149: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 149

Unit Size 015 020 025 030 035 040 042 016 2 021 026 031 2

Ref. Part No. Number 1A 113090101 1 113090102 1 113090104 1 1A 113163301(T) 5/15 & Earlier 1 500597801(T) 6/15 & Later 1 113163302(T) 4/15 & Earlier 1 1 500597802(T) 7/15 & Later 1 1 113163304(T) 5/15 & Earlier 1 1 500597804(T) 10/15 & Later 1 1 1A 113163401(T) 1 113163402(T) 1 113163404(T) 1 1A 113093901(T) 1 113093902(T) 1 113093904(T) 1 RPS Units only 1A 113094601(T) 8/10 & Earlier 1 113090401 9/10 thru 5/15 2 500597901(T) 6/15 & Later 1 113094602(T) 10/10 & Earlier 1 113090402 11/10 thru 6/15 2 500597902(T) 7/15 & Later 1 113090404 2 RCS Units only 1A 113094601(T) 11/10 & Earlier 1 113090401 12/10 & Later 2 113094602(T) 10/10 & Earlier 1 113090402 11/10 & Later 2 113090404 2

Section M- Condenser Section Compressors Circuit #2: Code 44= R 3

Standard Scroll Compressor Units: Circuit #2 3

208/

230V

460V

575V

208/

230V

460V

575V

208/

230V

460V

575V

208/

230V

460V

575V

208/

230V

460V

575V

208/

230V

460V

575V

208/

230V

460V

575V

(T)= Tandem compressor assembly.1 For units built during the transition, use the Distributor Tools BOM Search function on the Daikin Parts website or contact Daikin

Applied with model and serial number information to ensure that the correct part(s) are identified. Note that these compressors are NOT drop in substitutions for each other because the piping connections are NOT in the same location.

2 Starting 04/15 ALL 016D AND 031D units have been converted to use Inverter Compressors ONLY. For Inverter Compressor units (Code 44= V, W) refer to form 7000512.

3 Note that there are some Digital Scroll Compressor units built as SPECIALS with Code 44= R AND Code 60= XX WITH DIGITAL SCROLL COMPRESSORS listed as a special feature (refer to the Notes page at the beginning of the Condenser OR Control Box Section [Section N] for more information). For units with a Digital Compressor in Circuit # 2, refer to two pages after next.

Page 150: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 150

Section M- Condenser Section Compressors Circuit #2: Code 44= R, Continued 3

Unit Size 015 020 025 030 035 040 042 016 2 021 026 031 2

Ref. Part No. Number

Standard Scroll Compressor Units: Circuit #2 3

208/

230V

460V

575V

208/

230V

460V

575V

208/

230V

460V

575V

208/

230V

460V

575V

208/

230V

460V

575V

208/

230V

460V

575V

208/

230V

460V

575V

RPS Units only 1A 113094901(T) 8/10 & Earlier 1 113090701 9/10 & Later 1 113094902(T) 9/10 & Earlier 1 113090702 10/10 & Later 1 113094904(T) 1 RCS Units only 1A 113094901(T) 10/10 & Earlier 1 113090701 11/10 & Later 1 113094902(T) 10/10 & Earlier 1 113090702 11/10 & Later 1 113094904(T) 4/10 & Earlier 1 113090704 5/10 & Later 1 1A 113094901(T) 8/10 & Earlier 1 113090701 9/10 thru 3/15 1 2 500597401 6/15 & Later 1 2 113094902(T) 11/10 & Earlier 1 113090702 12/10 thru 4/14 1 2 500597402 6/15 & Later 1 2 113094904(T) 9/10 & Earlier 1 113090704 10/10 thru 6/15 2 500597404 6/15 & Later 1 2(T)= Tandem compressor assembly.1 For units built during the transition, use the Distributor Tools BOM Search function on the Daikin Parts website or contact Daikin

Applied with model and serial number information to ensure that the correct part(s) are identified. Note that these compressors are NOT drop in substitutions for each other because the piping connections are NOT in the same location.

2 Starting 04/15 ALL 016D AND 031D units have been converted to use Inverter Compressors ONLY. For Inverter Compressor units (Code 44= V, W) refer to form 7000512.

3 Note that there are some Digital Scroll Compressor units built as SPECIALS with Code 44= R AND Code 60= XX WITH DIGITAL SCROLL COMPRESSORS listed as a special feature (refer to the Notes page at the beginning of the Condenser OR Control Box Section [Section N] for more information). For units with a Digital Compressor in Circuit # 2, refer to one page after next.

Page 151: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 151

Section M- Condenser SectionCompressor Crankcase Heaters &

Compressor Mounting: Code 44= R 3

Due to the number of different mounting options used during production, contact Daikin Applied with model and serial number information to ensure that the correct mounting components are identified.

Part Number Unit Unit Unit Date Compressor Compressor Compressor Compressor Size Voltage Type Used 1 2 3 4 015/016 2 ALL ALL ALL 2 112056402 112056402 N/A N/A 020/021 208/230 ALL 5/15 & Earlier 112056401 112056402 N/A 112056402 020/021 208/230 ALL 6/15 & Later 112056402 910158757 N/A 910158757 020/021 460 ALL 9/14 & Earlier 4 112056401 112056402 N/A 112056402 020/021 460 ALL 7/15 & Later 4 112056402 910158757 N/A 910158757 020/021 575 ALL 6/15 & Earlier 4 112056401 112056402 N/A 112056402 020/021 575 ALL 10/15 & Later 4 112056402 910158757 N/A 910158757 025/026 ALL ALL ALL 112056401 112056402 N/A 112056402 030/031 2 ALL ALL ALL 2 113108903 112056402 N/A 112056402 035 ALL RPS 5/15 & Earlier 4 112056401 112056401 112056401 112056401 035 ALL RPS 7/15 & Later 4 112056402 112056402 112056402 112056402 035 ALL RCS ALL 112056401 112056401 112056401 112056401 040 ALL ALL ALL 112056401 112056401 112056401 112056401 042 ALL RPS 6/15 & Earlier 112056401 112056401 112056401 112056401 042 ALL RPS 7/15 & Later 112056402 112056402 112056402 112056402N/A= Not available.1 One Crankcase heater is used per compressor.2 Starting 04/15 ALL 016D AND 031D units have been converted to use Inverter Compressors ONLY. For Inverter Compressor units

(Code 44= V, W) refer to form 7000512.3 Note that there are some Digital Scroll Compressor units built as SPECIALS with Code 44= R AND Code 60= XX WITH DIGITAL

SCROLL COMPRESSORS listed as a special feature (refer to the Notes page at the beginning of the Condenser OR Control Box Section [Section N] for more information). For units with a Digital Compressor in Circuit # 2, refer to the following page.

4 For units built during the transition, use the Distributor Tools BOM Search function on the Daikin Parts website or contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified.

Standard Scroll Compressor Crankcase Heaters 1

Standard Scroll Compressor Mounting

Page 152: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 152

Unit Size 015 020 025 030 035 042 021 026 031

Ref. Part No. Number N/S 500596701 (D) 1 500596702 (D) 1 500596704 (D) 1 500597701 (D) 1 500597702 (D) 1 500597704 (D) 1 500597101 (D) 1 500597102 (D) 1 500597104 (D) 1 500597201 (D) 1 500597202 (D) 1 500597204 (D) 1 500596801 (TD) 1 500596802 (TD) 1 500596804 (TD) 1 500596901 (D), Cmpr. # 2 1 500596902 (D), Cmpr. # 2 1 500596904 (D), Cmpr. # 2 1

Section M- Condenser Section Compressors Circuit #2: Code 44= R OR D 1

& Compressor Crankcase Heaters

Digital Scroll Compressor Units: Circuit #2 1

208/

230V

460V

575V

208/

230V

460V

575V

208/

230V

460V

575V

208/

230V

460V

575V

208/

230V

460V

575V

208/

230V

460V

575V

Part Number Unit Unit Compressor Compressor Compressor Compressor Size Voltage 1 2 3 4 015 All N/A 112056402 N/A N/A 020 All N/A 112056402 N/A 112056402 025 All N/A 112056401 N/A 112056401 030 All N/A 113108903 N/A 113108903 035 All N/A 3 N/A 3

040 All N/A 112056401 N/A 112056401

Digital Scroll Compressor Units Crankcase Heaters 2

N/A= Not available.2 One Crankcase heater is used per compressor.3 The position of the Digital Scroll Compressor varies. Confirm which compressor requires a new heater and

then use the Distributor Tools BOM Search function on the Daikin Parts website or contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified.

N/S= Not shown on diagram.(D)= Digital compressor. (TD)= This is a Tandem compressor assembly with one (1) Digital and one (1) Standard Scroll. To determine whether to

replace the tandem OR ONE OF THE compressors in the tandem assembly contact Daikin Applied.1 Note that there are some Digital Scroll Compressor units built as SPECIALS with Code 44= R AND Code 60= XX

WITH DIGITAL SCROLL COMPRESSORS listed as a special feature (refer to the Notes page at the beginning of the Condenser OR Control Box Section [Section N] for more information). It is important to note that DIGITAL COMPRESSORS ARE ALWAYS LOCATED IN CIRCUIT # 2.

Page 153: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 153

Section M- Condenser Section Digital Scroll Compressor Components & T12, T13 Transformers/Fusing

CDT, SV7

Unit Size Ref. Part Part 015 020 025 030 035 040 No. Description Number 016 021 026 031 042 01 Thermistor, Discharge (CDT) 910156749 1 1 1 Thermistor, Discharge (CDT) 910139660 1 1 1 02 Strap, Thermistor 910156829 1 1 1 202 Kit, Valve/Coil/Tubing, 24V (SV7) 910157571 1 Kit, Unloader Coil, 120V (SV7) 910139659 1 1 1 1 Kit, Valve/Coil, 24V (SV7) 910156848 1 1 F12A, B Fuse- T12 Primary 2 208V 349937127 2 2 2 2 2 2 460V 049759809 2 2 2 2 2 2 F12C Fuse- T12 Secondary 4EHG7663 1 1 1 1 1 1 T12 Transformer- 115/24V 2

208V 099477202 1 1 1 1 1 1 460V 099477102 1 1 1 1 1 1 N/S Cover- Terminals 099477501 1 1 1 1 1 1 N/S Cover/Fuseholder 099477401 1 1 1 1 1 1 T13 Transformer- 115/24VAC 349937203 1 1 1 1 1 1 N/S Compressor Mounting Kit 300000462 1 1 1 1 1 1

01 202

02

N/S= Not shown on diagram.1 Note that 020, 021D units can be built with EITHER a 120V OR a 24V coil. Confirm the voltage of the coil required

BEFORE ordering, or contact Daikin Applied with model and serial number information to ensure that the correct coil is identified.

2 For voltages not shown use the Distributor Tools BOM Search function on the Daikin Parts website or contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified.

DCC

TB35/TB36

TD1 TD2

T29

VFD11 VFD21

R90

F11 F21

Control Box Detail Digital Compressor Detail

Page 154: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 154

Ref. Part Part Unit Size No. Description Number 015 016 3 020 021 025 026 Condenser Coils Code 43= M* N/S 27" x 48" 6/13 & Earlier 500461001 4 4 4 27" x 48" 7/13 thru 4/14 1 4 4 4 27" x 48" 5/14 & Later 910137828 4 4 4 27" x 93" 7/13 & Earlier 500510601 4 4 4 27" x 93" 8/13 & Later 1 4 3 4 4 Condenser Coils Code 43= T* N/S 27" x 48" 910152748 4 4 4 27" x 93" 910151864 4 3 4 4 Condenser Coils, Coated Code 43= P* N/S 27" x 48" 6/13 & Earlier 500461002 4 4 4 27" x 48" 7/13 & Later 910137829 4 4 4 27" x 93" 10/13 & Earlier 500510602 4 4 4 27" x 93" 11/13 & Later 1 4 3 4 4 Condenser Coils, Coated Code 43= U* 27" x 48" 910152749 4 4 4 27" x 93" 910151865 4 3 4 4 N/S Pressure Switches Low Pressure FanTrol Unit Code 47= 1, 3 403585101 2 2 2 2 2 2 SpeedTrol Units Code 47= 2, 4 910139364 2 2 2 2 2 2 2 High Pressure 403585001 2 2 2 2 2 2 101 Coil Guard RPS Side 403817900 1 1 1 Side 403834900 1 3 1 1 RCS Side 403817900 2 3 2 2 106 Coil Guard- RPS Only Side- Control Box 403824200 1 3 1 1 Side- Control Box 403823000 1 1 1 Side- Control Box 403835000 105 Coil/Tube Guard 403794800 1 1 3 1 1 1 N/S Vandal Guard Kit RPS 403909501 1 1 1 RPS 403909503 1 3 1 1 RCS 403909511 1 1 1

Section M- Condenser SectionCondenser Coils, Pressure Controls, Coil & Vandal Guards

N/S= Not shown on Diagram.1 Use the Distributor Tools BOM Search function on the Daikin Parts website or contact Daikin Applied with model and serial number

information to ensure that the correct part(s) are identified.2 This Pressure Switch replaces a Switch with a lower pressure rating. P/N 910139364 has the currently recommended pressure ratings.3 Starting 04/15 ALL 016D units have been converted to use Inverter Compressors ONLY. For Inverter Compressor units (Code 44= V, W)

refer to form 7000512.

Page 155: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 155

Ref. Part Part Unit Size No. Description Number 030 031 035 040 042 Condenser Coils Code 43= M* N/S 27" x 71" 7/13 & Earlier 500460901 4 4 4 27" x 71" 8/13 & Later 910137830 4 4 4 27" x 93" 7/13 & Earlier 500510601 4 4 27" x 93" 8/13 & Later 1 4 3 4 Condenser Coils Code 43= T* N/S 27" x 71" 910152746 4 4 4 27" x 93" 910151864 4 3 4 Condenser Coils, Coated Code 43= P* N/S 27" x 71" 7/13 & Earlier 500460902 4 4 4 27" x 71" 8/13 & Later 910137831 4 4 4 27" x 93" 10/13 & Earlier 500510602 4 4 27" x 93" 11/13 & Later 1 4 3 4 Condenser Coils, Coated Code 43= U* N/S 27" x 71" 910152747 4 4 4 27" x 93" 910151865 4 3 4 N/S Pressure Switches Low Pressure FanTrol Unit Code 47= 1, 3 403585101 2 2 2 2 2 SpeedTrol Units Code 47= 2, 4 910139364 2 2 2 2 2 2 High Pressure 403585001 2 2 2 2 2 SpeedTrol Pressure Code 47= 2, 4 403586901 2 2 2 2 2 Pressure Transducer Harness 403586601 2 2 2 2 2 N/S Line Reactor- SpeedTrol (575V) Code 47= 2, 4 073323552 2 2 2 2 2 101 Coil Guard RPS Side 403795200 1 1 1 Side 403834900 1 3 1 RCS Side 403795200 2 2 2 Side 403834900 2 3 2 106 Coil Guard- RPS Only Side- Control Box 403824200 1 1 1 Side- Control Box 403823000 1 3 1 Side- Control Box 403835000 105 Coil/Tube Guard 403794800 1 1 3 1 1 N/S Vandal Guard Kit RPS 403909502 1 1 1 RPS 403909503 1 3 1 RCS 403909512 1 1 1

Section M- Condenser SectionCondenser Coils, Pressure Controls, Coil & Vandal Guards, Continued

N/S= Not shown on Diagram.1 Use the Distributor Tools BOM Search function on the Daikin Parts website or contact Daikin Applied with model and serial number

information to ensure that the correct part(s) are identified.2 This Pressure Switch replaces a Switch with a lower pressure rating. P/N 910139364 has the currently recommended pressure ratings.3 Starting 04/15 ALL 031D units have been converted to use Inverter Compressors ONLY. For Inverter Compressor units (Code 44= V, W)

refer to form 7000512.

Page 156: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 156

Section M- Condenser SectionPressure Controls: (03/2013 & Earlier)

AFD11, AFD21, LR11, LR21, LP1, LP2, HP1, HP2, PC13, PC23RPS Units Only

237

AFD11 AFD21

LR11 LR21

PC23

SPTRL

SPTRL

HP1

HP2

LP1

LP2

PC13236

237

235

234234

236

235

244

246

238 239 typ.

238

238

238

238

238

238

Ref. Sch. Part Part Qty. No. Sym. Description Number 234 LP1, 2 Switch- Low Pressure FanTrol Unit Code 47= 1, 3 403585101 2 SpeedTrol Unit Code 47= 2, 4 910139364 1 2 235 HP1, 2 Switch- High Pressure 403585001 2 236 PC13, 23 Switch- Fan Pressure 403585601 2 237 SPTRL Switch- SpeedTrol Pressure Code 47= 2, 4 403586901 2 2

238 Valve Core 026541100 10 239 Valve Cap FanTrol Unit Code 47= 1, 3 032943500 6 SpeedTrol Unit Code 47= 2, 4 032943500 4 244 AFD11, 21 Inverter 208/230V 193475804 2 Inverter 460V 193475821 2 Inverter 575V 193456301 2 246 LR11, 21 Line Reactor 575V only (Code 09= 37) 073323552 21 This Pressure Switch replaces a Switch with a lower pressure rating. P/N 910139364 has the currently recommended pressure

ratings.2 On FanTrol units, there is a Valve Core and Valve Cap (Ref. # 238, 239) in place of each of the SPTRL Switches.

Page 157: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 157

239

237

235

244

236

237

234

243

238

239238

238

238

238

238

See Factory Supplied Line Voltage Option

Section

233

238

247

236 238

235

Section M- Condenser SectionPressure Controls: (04/2013 & Later)

AFD11, AFD21, LR11, LR21, LP1, LP2, HP1, HP2, PC13, PC23RPS Units Only

Ref. Sch. Part Part Qty. No. Sym. Description Number 233, 234 LP1, 2 Switch- Low Pressure FanTrol Unit Code 47= 1, 3, 5 403585101 2 SpeedTrol Unit Code 47= 2, 4, 6 910139364 2 235 HP1, 2 Switch- High Pressure 403585001 2 236 PC13, 23 Switch- Fan Pressure 403585601 2 237 SPTRL Switch- SpeedTrol Pressure Code 47= 2, 4, 6 403586901 1 2 238 - Valve Core 026541100 10 239 - Valve Cap FanTrol Unit Code 47= 1, 3, 5 032943500 6 SpeedTrol Unit Code 47= 2, 4, 6 032943500 4 243, 244 VFD11, 21 SpeedTrol VFD Code 54= YY 208/230V, 1HP 193552243 2 2 460V, 1HP 193552293 2 2 575V, 1HP 193456301 3 2 243 VFD11 SpeedTrol VFD Code 54= BM 208/230V 193552243 2 1 460V, 1HP 193552293 2 1 575V, 1HP 193456301 3 1 244 VFD21 SpeedTrol VFD Code 54= BM 208/230V 193552214 2 1 460V, 3HP 193552201 2 1 575V 193456301 3 11 On FanTrol units, there is a Valve Core and Valve Cap (Ref. # 238, 239) in place of each of the SPTRL Switches.2 Note that ABB brand VFDs are offered as STANDARD. Confirm brand of VFD required BEFORE ordering or contact Daikin

Applied with model and serial number information to ensure that the correct part(s) are identified. The replacement ABB brand VFD Keypad is p/n 300040924

3 For replacement VFD components, contact Daikin Applied with model and serial number information so that the correct part(s) can be identified.

Page 158: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 158

Section M- Condenser SectionPressure Controls- Manifold Mounted

HP1, HP2, LP1, LP2, SPTRLRCS Units Only 1

138 139 138 137

135

138 134

135

138 134

Circuit # 2 Circuit # 1

Ref. Sch. Part Part Qty. No. Sym. Description Number 134 LP1, 2 Switch- Low Pressure FanTrol Unit Code 47= 1, 3 403585101 2 SpeedTrol Unit Code 47= 2, 4 910139364 2 2 135 HP1, 2 Switch- High Pressure 403585001 2 137 SPTRL Switch- SpeedTrol Pressure Code 47= 2, 4 403586901 2 138 Valve Core 026541100 10 139 Valve Cap FanTrol Unit Code 47= 1, 3 032943500 8 SpeedTrol Unit Code 47= 2, 4 032943500 6

SpeedTrol(Code 47= 2, 4)

FanTrol(Code 47= 1, 3)

SpeedTrol(Code 47= 2, 4)

FanTrol(Code 47= 1, 3)

138 139 138 139

138 134

135

138 139138 137

135

138 134

1 For RCS units, the SpeedTrol Inverters- AFD11, AFD21 (and Line Reactors for 575V units) are located in the RCS Control box, and the pressure controls for the Compressor and FanTrol are located on the control box manifolds.

2 This Pressure Switch replaces a Switch with a lower pressure rating. P/N 910139364 has the currently recommended pressure ratings.

Page 159: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 159

Section M- Condenser SectionPressure Controls- Manifold Mounted, Digital Compressor Units

HP1, HP2, LP1, LP2, SPTRL, Continued

133

138 135

138135

138 134

Circuit # 2 Circuit # 1

Ref. Sch. Part Part Qty. No. Sym. Description Number 133 PC29 Switch, Pressure, Coil Splitter 403585601 1 134 LP1, 2 Switch- Low Pressure Speedtrol Unit Code 47= 2, 4 910139364 2 135 HP1, 2 Switch- High Pressure 403585001 2 136 SPTRL Switch- Speedtrol Pressure Code 47= 2, 4 910153045 1 137 SPTRL Switch- Speedtrol Pressure Code 47= 2, 4 403586901 1 138 Valve Core 026541100 11 139 Valve Cap 032943500 4 140 Pressure Switch Harness 72" 403586601 1

Pressure Switch Harness 144" 403586602 1

Pressure Switch Harness 36" 403586603 1

Speedtrol(Code 47= 2, 4)

Speedtrol(Code 47= 2, 4)

136 138

138 139

138134

137 138

139 138

138

1 Confirm cable length required BEFORE ordering.

140 140

Page 160: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 160

Section M- Condenser SectionCondenser Control Box (RCS Units Only)

No Controls: Code 12= YM 1

Diagrams 2

RCS with no controls: Code 12= YM 03/2013 & Earlier

RCS with no controls: Code 12= YM 04/2013 & Later

1 For more information on RCS Standalone Units (Code 12= YA, 1A, 2A) refer to form # 7000197.2 The above diagrams show typical Condenser Control Box layouts and are to be used for reference only. Specific unit configuration may differ depending upon unit size and options selected.

PL25- PL30Plugs

PL25- PL30Plugs

Page 161: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 161

Section M- Condenser SectionCondenser Control Box (RCS Units Only)

MicroTech III ControlsCode 12= SE, SF, SW

Diagrams 1

RCS with MicroTech III Controls: Code 12= *E, *F, *W 03/2013 & Earlier

RCS with MicroTech III Controls: Code 12= *E, *F, *W 04/2013 & Later

1 The above diagrams show typical Standard Scroll Compressor Control Panel layouts and are to be used for reference only. Specific unit configuration may differ depending upon unit size and options selected.

PL25- PL30Plugs

PL25- PL30Plugs

Page 162: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 162

Section M- Condenser SectionCondenser Control Box

RCS 015- 042 Components

Ref. Part Part Unit Size No. Description Number 015 020 025 030 035 040 042 DCC Digital Compressor Controller 910139658 1 1 1 1 1 1 1 S2 Switch- System 001355000 1 1 1 1 1 1 1 REC2 Receptacle 039003100 1 1 1 1 1 1 1 Time Delays (Code 12= YM) TD1, 2 Time Delays, Compr. Lockout 6 2 2 2 2 2 2 2 TC12 Temperature Control- FanTrol 041763500 1 1 1 1 1 1 1 Ground Fault Protection GFR4 Ground Fault Relay- SPDT 349937502 1 1 1 1 1 1 1 GFS4 Ground Fault Sensor 349937404 1 1 1 1 1 1 1 Phase Voltage Monitor (PVM) PVM4 208/230/460V (12/16 & Earlier) 112022001 1 1 1 1 1 1 1 575V (12/16 & Earlier) 112022002 1 1 1 1 1 1 1 208/230/460V (1/17 & Later) 193599301 1 1 1 1 1 1 1 575V (1/17 & Later) 193599303 1 1 1 1 1 1 1 - Socket, PVM (1/17 & Later) 193599401 1 1 1 1 1 1 1 PL25- 30 Plugs- 12 Pin 349930405 2 2 2 3 4 4 4 T9 Transformer- 115/24VAC 349937203 1 1 1 1 1 1 1 Terminal Blocks TB1 Terminal Block 349930605 1 1 1 1 1 1 1

TB3, 5, 6, 8 Terminal Block 349930603 2 2 2 2 2 2 2

TB35 Terminal Block Assy. 910150442 1 1 1 1 1 1 1 TB36 Terminal Block Assy. 404148501 1 1 1 1 1 1 1 Contactors/Motor Protectors M1- 4 Contactor- Compressors 3 M11- M22 Contactor- Fan Motors 3

MMP1- 4 MMP- Compressors 3 MMP11, 12 MMP- Fan Motors 3 Power Block PB4 Power Block, Main 175A 030372777 4

310A, 420A 030372785 4

Relays R1 Relay- Hi Pressure Reset 349934724 1 1 1 1 1 1 1 R2 Relay- Hi Pressure Reset 349934724 1 1 1 1 1 1 1 R5 Relay- Safety 349934724 1 1 1 1 1 1 1 R6 Relay- Safety 349934724 1 1 1 1 1 1 1 R7 Relay- Safety 349934724 1 1 1 R8 Relay- Safety 349934724 1 1 1 1 1 1 R12 Relay- Condenser Fan 349934724 1 1 1 1 1 1 1 R31- 36 Relay- Compressor Staging 349934722 5 5 5 5 5 5 5

R70- 90 Relays- Digital Compressor 349934724 5 5 5 5 5 5 5

1 Varies depending on unit options. Part number is for one individual section. Ground block is p/n 349930606.2 Varies depending on unit options. Part number is for one individual section. Ground block is p/n 349930604.3 Even though these components are installed in the RCS unit Condenser Control Box, Compressor and Condenser Fan Motor

Contactors, Manual Motor Protectors and associated parts are detailed in the Main Control Box Section (Section N). 4 Any of the listed parts may be used, depending on unit options. Check the installed part to verify, use the Distributor Tools

BOM Search function on the Daikin Parts website, or contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified.

5 Varies depending on unit options.6 Two Time Delay relays have been furnished. The most common is the NON-Adjustable type p/n 193464401. The ADJUSTABLE

version of this relay could also have been supplied: p/n 300046580. Confirm which relay is required BEFORE ordering.

Page 163: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 163

Section M- Condenser SectionCondenser Control Box

RCS 015- 042Components, Continued

Disconnect Switches 03/2013 & Earlier Sch. Part Part Voltage Sym. Description Number 208V 230V 460V 575V Disconnect Switch 1

DS4 Disconnect Switch- Condenser Control Box Switch- 100A 349935125 1 1 1 1 Handle Kit (with operating mechanism) 349935521 1 1 1 1 Shaft 349962208 1 1 1 1 Ground Lug 349938001 1 1 1 1 Switch- 150A 349935126 1 1 1 1 Handle Kit (with operating mechanism) 349935532 1 1 1 1 Shaft 349962208 1 1 1 1 Ground Lug 349938001 1 1 1 1 Switch- 250A 349935226 1 1 1 1 Handle Kit (with operating mechanism) 349935532 1 1 1 1 Shaft 349962208 1 1 1 1 Ground Lug 349938002 1 1 1 1 Switch- 400A 349935325 1 1 1 1 Handle Kit (with operating mechanism) 349935621 1 1 1 1 Shaft 349962210 1 1 1 1 Ground Lug 349938002 1 1 1 1 1 Disconnects are sized according to various unit specifications. Check the installed switch to verify, use the Distributor Tools BOM

Search function on the Daikin Parts website, or contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified.

Sch. Part Part Voltage Sym. Description Number 208V 230V 460V 575V Disconnect Switch 2

DS4 Disconnect Switch- Condenser Control Box Switch- 100A 193444703 1 1 1 1 Handle 193422102 1 1 1 1 Shaft, 6 mm 3 300040562 1 1 1 1 Switch- 150A 193585101 1 1 1 1 Handle 193422102 1 1 1 1 Mechanism 193550801 1 1 1 1 Shaft, 6 mm 3 300040562 1 1 1 1 Lugs 5 193553301 1 1 1 1 Switch- 250A 193551601 1 1 1 1 Handle 193595701 1 1 1 1 Mechanism 193551001 1 1 1 1 Shaft, 10 mm 4 300040299 1 1 1 1 Lugs 5 193553801 1 1 1 1 Switch- 400A 193551701 1 1 1 1 Handle 193595701 1 1 1 1 Mechanism 193551001 1 1 1 1 Shaft, 10 mm 4 300040299 1 1 1 1 Lugs 5 193554001 1 1 1 1 2 Disconnects are sized according to various unit specifications. Check the installed switch to verify, use the Distributor Tools BOM

Search function on the Daikin Parts website, or contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified.

3 This shaft is 6 millimeters square (.236”) and 430 millimeters long (16.9”). It designed to be cut to the required length in the field.4 This shaft is 10 millimeters square (.394”) and 500 millimeters long (19.6”). It designed to be cut to the required length in the field.5 Three Lugs are included with each p/n.

Disconnect Switches 04/2013 & Later

Page 164: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 164

Section M- Condenser SectionFactory Supplied Line Voltage Option T6, DS6, FU6A, FU6B, FU6C, TB7, TB8

Code 18= U***, V*** OR Code 23= ***F* 1

Typical Pressure Control Box

DS6

TB7

Main Control Box

94

5

3

248

249247

Voltage

Ref. Sch. Part Part No. Sym. Description Number 247 T6 Transformer, 2kVA 3/13 & Earlier 349939818 1 Transformer, 2kVA 4/13 & Later 099477214 1 Transformer, 2kVA 3/13 & Earlier 349939808 1 1 Transformer, 2kVA 4/13 & Later 099477114 1 1 Transformer, 2kVA 3/13 & Earlier 349939828 1 Transformer, 2kVA 4/13 & Later 099477314 1 248 - Finger Safe Cover Kit 3/13 & Earlier 349955901 1 1 1 1 Terminal Cover Kit 4/13 & Later 099477602 1 1 Terminal Cover Kit 4/13 & Later 099477601 1 3 DS6 Fuse Holder/Circuit Protector, 30A, 600V 12/17 & Earlier 193443801 1 1 1 1 Fuse Holder/Circuit Protector, 30A, 600V 1/18 & Later 349946202 1 1 1 1 4 - Terminal Block End Stop, Grey 4/13 & Later 349930841 2 2 2 5 FU6A, B Fuse, 20A/600V 349937135 2 2 Fuse, 10A/600V 349937131 2 Fuse, 8A/600V 349937129 2 6 Fuseblock, 1P, 30A, 500V 3/13 & Earlier 023780223 1 1 1 1 249 FU6C Fuse, 20A/600V 349937036 1 1 1 1 8 Fuse Cover/Puller 3/13 & Earlier 349938227 1 1 1 1 9 TB7, 8 Terminal Block Assembly 2 4/13 & Later Terminal Block 2 x 2, Grey 349930641 2 2 2 2

Terminal Block End Plate, Grey 349930741 2 2 2 2

Terminal Block End Stop, Grey 349930841 2 2 2 2

208V

230V

460V

575V

1 The above diagrams show typical DS6 layouts and are to be used for reference only. Specific unit configuration may differ depending upon unit size and options selected.

2 This Terminal Block Assembly consists of all three parts listed. The Terminal Block quantity varies so confirm the quantity of WHICH parts are required BEFORE ordering.

Main Control Box

DS6

F6A F6B F6C

DS1

MMP1

M1

249

3 65

Page 165: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 165

Section N- Main Control BoxNotes

Primary Codes that pertain: 09, 11, 12, 13, 14, 15, 17, 18, 44, 47 AND 23, 54, 68 (Mid 2012 & Later)Additional Codes that pertain: 04, 19, 20, 22, 27, 32, 34, 35, 40

The Main Control Box applies to RPS & RFS units. RCS units have their own Controls that are detailed in Section M. The Main Control Box is normally mounted in the Discharge Plenum Section (Section K) and is comprised of three primary parts— The Dead front Door with Keypad, the Control Panel, and the Power Panel.

In March and April of 2013, the Main Control Box underwent a major redesign. This design change not only changed components, but some Contactor, Motor Protector, and VFD circuiting changed. Note that components and component accessories such as Auxiliaries, Links, etc. are NOT interchangeable. For units built and shipped during the transition, use the Distributor Tools BOM Search function on the Daikin Parts website, or contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified.

Code 9 determines unit voltage and affects the Transformers, Motor Protectors/MMPs, Contactors, Fuses, etc.

Code 11 determines whether the main power connection is a Terminal Block or a through-the-door Disconnect Switch.

Code 12 determines which type of communication option the unit has (LonMark, BACNet/MSTP, BACNet/IP, or None) and whether the unit uses Discharge Temperature, Space Control, or Zone control. There is an MCB and separate Expansion Boards in the control panel. Units may also have no factory installed controls (Code 12= YM, YC) in which case the Main Control Box has no MCB or Expansion boards, but instead has a set of relays. RCS Standalone Units (units that are designed to be used as a standalone condensing unit, or intended to be hooked to a separate Air Handler unit) have additional codes which add Transformers. For RCS Standalone Unit specific information, (Code 12= *A), refer to RPL form # 7000197.

Code 13 determines the presence of Duct and/or Space Sensors.

Codes 14 and 15 determine the Supply AND Return Fan Inverter specifications.

Code 17 AND/OR 23 (Mid 2012 & Later) determine electrical options including a Freezestat, PVM (Phase Voltage Monitor), Ground Fault Protection, Line Reactors, Vestibule Lights, Service Outlet, Intelligent Equipment, etc.

Code 18 indicates whether a unit has a Remote Keypad Display AND/OR a unit mounted Receptacle.

Page 166: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 166

Section N- Main Control BoxNotes, Continued

Code 44 shows the type of compressor selected. Code 44= R NORMALLY stands for units with ALL standard scroll compressors. For units with Inverter Compressors (Code 44= V, W) refer to form 7000512. (Starting 04/15 ALL 016D, 031D units have been converted to use Inverter Compressors ONLY.) Starting in late 2014, some units are built as specials with digital scroll compressors with Code 44= R AND Code 60= XX with digital scroll compressors listed as a special feature (refer to the drawing below for an example of Special Code String Text). Digital Compressors add/change some Control Box components so confirm the presence of a Digital Compressor BEFORE ordering to ensure that the correct part(s) are identified. Code 44= D also indicates the presence of digital compressors.

Code 47 determines Condenser Fan operation: FanTrol [Standard operation] (Code 47= 1), or SpeedTrol [Low Ambient operation] (Code 47= 2). If Code 47= 3, the unit is equipped with optional Quiet Fan assemblies and FanTrol. If Code 47= 4, the unit is equipped with optional Quiet Fan assemblies and SpeedTrol. If Code 47= 5, the unit is equipped with optional TEAO Fan Motors and FanTrol. If Code 47= 6, the unit is equipped with optional TEAO Fan Motors and SpeedTrol. Note that some units were built as specials with Code 50 OR Code 60= XX with 1.5HP TEAO motors listed as a special feature. Confirm the presence of TEAO motors BEFORE ordering. Use the Distributor Tools BOM Search function on the Daikin Parts website or contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified.

Code 54 (Mid 2012 & Later) indicates if Modulating Hot Gas Reheat (MHGR) was chosen. This changes Condenser Fan circuiting by adding fusing and AFD/VFD fan control independent of Code 47.

Code 68 specifies the SCCR or “Short Circuit Current Rating” for the unit. Standard units are always rated at “10 SCCR” (Code 68= 10, OR no entry). An entry with any other rating (Eg: Code 68= 22, 65 OR indicated in the specials description in the Code String lookup) may change disconnect switches, circuit breakers, fuses, and other miscellaneous components. When Main Control box parts are required for units with nonstandard SCCR ratings, use the Distributor Tools BOM Search function on the Daikin Parts website or contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified.

Codes 19, 20, 22 are Return Air codes, and impact several controls options. The presence of an OA hood, the horsepower of the Return Air Motor, etc, have an impact on Contactors, Motor Protectors, Fuses, and Duct Sensors.

Code 27 determines the DrawThru section, and can impact the Cooling Circuit Relays.

Code 32 determines horsepower for the Supply Fan Motor which, like the Return Air Motor affects Contactors, Fuses, Motor Protectors, etc.

Codes 04, 34, and 35 determine the BlowThru section, and the heat type, which impact Transformers, Heat Circuit Relays, and Cooling Circuit Relays.

Code 40 determines if there is a VAV Damper and related Control Relay.

Page 167: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 167

Section N- Main Control BoxControl Panel- MicroTech III

Control Box Component Label Diagram 1

1 Note that starting in late 2010 all units will have a label similar to the one shown above pasted to the inside of the Control Box door. This label contains schematic designators, part descriptions, and Daikin Applied part numbers. The label shown above is for representative purposes only. Actual part numbers will vary depending upon unit options selected.

Page 168: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 168

Section N- Main Control Box Control Panel

Units with No Controller (Code 12= YM, YC)Diagram 1

1 The above diagram shows a typical Standard Scroll Compressor Control Panel layout and is to be used for reference only. Specific unit configuration may differ depending upon unit size and options selected.

Left Side Door Detail

DHL

See Power Panel

R1

R2

R24

R20

R25

R19

R18

R63

R8.1

R5.1

R6.1

R7.1

R9

R10

R11

S4 S7

HS1 S1 CS2 CS1

Left SideDoor

(see detail below)

R69

R68

R70

TD1 TD2

R67

R17

R13.1

R14.1

T4 T2

Switch Detail

Page 169: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 169

Section N- Main Control BoxControl Panel

Units with No Controller (YM, YC)Components

Sch. Part Part Qty. Sym. Description Number Digital Compressor Controller DCC Digital Compressor Controller 910139658 1 Relays R1, 2 Relay- Hi Pressure Reset 349934724 2 R5.1- 8.2 Relays- Safety 349934724 6 R9, R10 Relay- Compressor Lockout 349934724 2 R11,R12 Relay- SpeedTrol Fan Cycling (036, 040 only) Code 47= 2, 4 349934724 2 R18, R19 Relay- Cooling Failure Indicator 349934722 2 R20 Relay- Steam or Hot Water Heat Code 04= S, W 349934724 1 Relay- Electric Heat Code 04= E 349934722 1 Relay- Gas Heat 1 Code 04= A Units w/ No Controller & Gas Actuator Code 12= YC Hi Turn Down Burner Code 34 (5th digit)= H,T,U 073340001 1 Modulating Burner Code 34(5th digit)= E,R,S 027400700 1 Units w/ No Controller & Float Control Code 12= YM Hi Turn Down Burner Code 34 (5th digit)= H,T,U 019643000 1 Modulating Burner Code 34(5th digit)= E,R,S 027400700 1 R24 Relay- Gas Heat Alarm Code 04= A 349934724 1 R25 Relay- Gas Heat, Start Supply Fan Inverter Code 14= 1, 2,3,5,6,7 349934724 1 R26 Relay- Iso Damper- Open/Close 349934921 1 R30 Relay- Cool Valve w/ Face Bypass 349934724 1 R41- 43 Relays- Condenser Fan 349934724 3 R45 Relay- UV Lights 349934722 1 R46 Relay- Inverter, Supply Fan increase/decrease Code 14= 1-3,5-7 112033501 1 R48 Relay- Inverter, Return Fan increase/decrease Code 14= 2,4,5,7-9 112033501 1 R58 Relay- Heat Wheel increase/decrease Code 24= F 112033501 1 R60 Relay- Heat Wheel Enable 349934724 1 R63 Relay- Specials 349934921 1 R66 Relay- Return Air Smoke Detector Code 16= 1, 3 349934722 1 R67 Relay- Supply Fan Enable No Controller w/o Inverter or w/Inverter/no Bypass C12= YM, YC 349934724 1 No Controller w/ Inverter and Bypass C12= YM, YC 349934722 1 R68 Relay- Return Fan Enable 349934724 1 R69 Relay- Inverter Bypass VAV Interlock Code 14= 1- 9 349934724 1 R70- 88 Relays- Specials 349934724 2

Duct Hi Limit and Static Pressure Sensors DHL Duct Hi Limit Switch 065493801 1 SPS1 Pressure Transducer- Duct Sensor Code 13= 1, 2, 3 049545007 1 SPS2 Pressure Transducer- Duct Sensor Code 13= 2 049545007 1 Pressure Transducer- Space Sensor Code 13= 3, 4 049545006 1 Transformers- Controls T2 Transformer- Control Input 115- 24V With Controller Code 12= *D, *S 349937301 1 No Controller Code 12= YM, YC 349937203 1 T3 Transformer- Control Output 115- 24V 349937301 1 T4 Transformer- Exhaust Damper Actuator 115- 12VDC 349931801 1 T9 Transformer- Refrigerant Circuit 24V 349937203 11 All R20 options are detailed here but for units with gas heat, the R20 is located in the gas heat control box (see Section G). 2 Quantity varies depending on unit options.

Page 170: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 170

Section N- Main Control Box Control Panel

MicroTech III Units with Controller (Code 12= *E, *F, *W): (03/2013 & Earlier)Diagram 1

See Power Panel

1 The above diagram shows a typical Control Panel layout and is to be used for reference only. Specific unit configuration may differ depending upon unit size and options selected.

Page 171: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 171

Section N- Main Control BoxControl Panel

MicroTech III Units with Controller (Code 12= *E, *F, *W): (03/2013 & Earlier)Components

Sch. Part Part Qty. Sym. Description Number Main Controller MCB Main Controller- Must be programmed (unit GO# required) 193407301 1 - Battery, MCB 193409001 1 Connector, Extension I/O Direct Connect 193409701 2

Terminal Block, MCB- 2 Pole 193410302 1 Terminal Block, MCB- 3 Pole 193410303 6 Terminal Block, MCB- 5 Pole 193410305 1 Terminal Block, MCB- 6 Pole 193410306 1 Terminal Block, MCB- 7 Pole 193410307 1 Terminal Block, MCB- 8 Pole 193410308 2 - MTIII Remote Keypad/Human Machine Interface (HMI) Display 1 193408003 1 Expansion Module EXP A Expansion Module- Condenser/ Energy Recovery 193407501 1 EXP B Expansion Module- Heat 193407501 1 EXP D Expansion Module- Specials 193407501 1 Terminal Block, EXP- 2 Pole 193410302 1/board Terminal Block, EXP- 3 Pole 193410303 1/board Terminal Block, EXP- 7 Pole 193410307 1/board Terminal Block, EXP- 8 Pole 193410308 2/board Hot Gas Reheat Code 48= H, K RHB1, 2 Interface Boards, Modulating Hot Gas Reheat 113168901 2 Communication Card COM Bacnet- MSTP Code 12= BE, BF, BW 090016710 1 Bacnet- IP Code 12= EE, EF, EW 090016709 1 LonWorks- Discharge (Code 12= LE, LW) 090016712 1 LonWorks- Constant Volume (Code 12= LF) 090016711 1 Resistors 1

RES1 Resistor- Refrigeration Circuit #1 1500 OHM 044690151 1 RES2 Resistor- Refrigeration Circuit #2 1000 OHM 044690110 1 RES3 Resistor- Freezestat FS1 1000 OHM 044690110 1 RES4 Resistor- OAE 1500 OHM 044690151 1 RES6,7,8 Resistor- SPS1, SPS2, SPS3 500 OHM 044690146 1/switch Switches- Control HS1 Switch- Electric Heat Shutdown Code 04= E 001355000 1 S1 Switch- System On/Off Gas Heat Units with no UV Lights DPST/15A 018446400 1 Gas Heat Units with UV Lights 4PST/30A 033536700 1 Electric, Steam, HW, No Heat with no UV Lights SPST/20A 001355000 1 Electric, Steam, HW, No Heat with UV Lights DPST/15A 018446400 1 S4 Switch- Inverter Bypass On/Off DPST/15A 018446400 1 S7 Switch- Local On/Auto/Off to Controller SPDT/15A 193412101 1 Transformers T2, 3 Transformer- Control 120- 24V 349937303 1 Receptacle REC1 Receptacle 039003600 1 Duct Hi Limit and Static Pressure Sensors DHL Duct Hi Limit Switch 065493801 1 SPS1, 2 Pressure Transducer Kit- Duct Sensor (9/11 & Earlier) 3, 4 910124528 2

Pressure Transducer- Duct Sensor (10/11 thru 3/13) 3 910117462 2

Pressure Transducer Kit- Space Sensor (9/11 & Earlier) 3, 4 910124529 2

Pressure Transducer- Space Sensor (10/11 thru 3/13) 3 910117463 2

1 Not Shown on diagram. 2 Quantity varies depending upon unit options selected.3 SPS1 Duct Sensor Code 13= 1, 2, 3. SPS2 Duct Sensor Code 13= 2. SPS2 Space Sensor Code 13= 3, 4.4 As of 09/11 the original Pressure Transducer is no longer available. The Transducer Kit includes Transducer, Dinrail,

Resistor, Sampling Tube, and installation Instructions.

Page 172: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 172

Sch. Part Part Qty. Sym. Description Number Relays R12 Relay- Condenser Fan 349934724 1 R14 Relay- Condenser Fan 349934724 1 R20 Relay- Heat 349934724 1 R25 Relay- Gas Heat, Start Supply Fan Inverter Code 14= 1,2,3,5,6,7 349934724 1 R63 Relay- Duct Hi Limit Units with Supply Fan Inverter Code 14= 1, 3, 6 0 OR 1 Duct Sensor Code 13= Y, 1 349934724 1 2 Duct Sensors Code 13= 2 349934923 1 1 Duct & Space Sensor OR 1 Space Sensor Code 13= 3, 4 349934923 1 DHL Sensor Code 13= 5 349934921 1 Units with Supply & Return Fan Inverters Code 14= 2, 5, 7 Vars. Code 13= 1, 2, 3, 4, Y 349934923 1 R81 Relay- Smoke 4P/6A/24V 193413601 1 R82 Relay- Smoke 4P/6A/24V 193413601 1 R83 Relay- Smoke 4P/6A/24V 193413601 1 R84 Relay- Smoke 4P/6A/24V 193413601 1 R85 Relay- Smoke 4P/6A/24V 193413601 1 R86 Relay- Smoke 4P/6A/24V 193413601 1 R87 Relay- Smoke 4P/6A/24V 193413601 1 R88 Relay- Smoke 4P/6A/24V 193413601 1 Time Delay TD20 Time Delay 20 Second 028210106 1 Terminal Block TB1 Terminal Block 349930641 1

Sensors ZNT1 Sensor- Zone Temperature w/ Tenant Override 3 113117701 1 Sensor- Zone Temp. w/ Tenant Override & Remote Setpoint Adj. 2, 3 113117801 1 SHS1 Sensor, Humidity Duct Mounted 3 067295001 1 DAT Sensor- Discharge Air Temperature 3 193414602 1 EFT Sensor- Entering Air Temperature 3 193414602 1 OAT Sensor- Outside Air Temperature 3 193414602 1 RAT Sensor- Return Air Temperature 3 193414602 1 EAT Sensor- Exhaust Air Temperature 3 193414602 1 LAT Sensor- Leaving Air Temperature 3 193414602 1

Section N- Main Control Box Control Panel

MicroTech III Units with Controller (Code 12= *E, *F, *W): (03/2013 & Earlier)Components

1 Varies depending on unit options. Part number is for one individual section. Ground block is p/n 349930647.2 SCC Units only- Code 12= *F, *W.3 Not shown on diagram.

Page 173: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 173

Section N- Main Control Box Control Panel

MicroTech III Units with Controller (Code 12= *E, *F, *W): (04/2013 & Later)Diagram 1

See Power Panel

1 The above diagram shows a typical Standard Scroll Compressor Control Panel layout and is to be used for reference only. Specific unit configuration may differ depending upon unit size and options selected.

See

Pow

er P

anel

PL1

- PL4

3 Pl

ugs

Page 174: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 174

Section N- Main Control BoxControl Panel

MicroTech III Units with Controller (Code 12= *E, *F, *W): (04/2013 & Later)Components

Sch. Part Part Qty. Sym. Description Number Controllers MCB Main Controller- Must be programmed (unit GO# required) 193407301 1 - Battery, MCB 193409001 1 Connector, Extension I/O Direct Connect 193409701 2

Terminal Block, MCB- 2 Pole 193410302 1 Terminal Block, MCB- 3 Pole 193410303 6 Terminal Block, MCB- 5 Pole 193410305 1 Terminal Block, MCB- 6 Pole 193410306 1 Terminal Block, MCB- 7 Pole 193410307 1 Terminal Block, MCB- 8 Pole 193410308 2 - MTIII Remote Keypad/Human Machine Interface (HMI) Display 1 193408003 1 DCC Digital Compressor Controller 910139658 1 Expansion Modules EXP A Expansion Module- Condenser/ Energy Recovery 193407501 1 EXP B Expansion Module- Heat 193407501 1 EXP D Expansion Module- Specials 193407501 1 Terminal Block, EXP- 2 Pole 193410302 1/board Terminal Block, EXP- 3 Pole 193410303 1/board Terminal Block, EXP- 7 Pole 193410307 1/board Terminal Block, EXP- 8 Pole 193410308 2/board Hot Gas Reheat 1 Code 48= H, K OR Code 54= BM RHB1, 2 Interface Boards, Modulating Hot Gas Reheat 113168901 2 Communication Cards COM Bacnet- MSTP Code 12= BE, BF, BW 090016710 1 Bacnet- IP Code 12= EE, EF, EW 090016709 1 LonWorks- Discharge Code 12= LE, LW 090016712 1 LonWorks- Constant Volume Code 12= LF 090016711 1 Resistors 1

RES1 Resistor- Refrigeration Circuit #1 1500 OHM 044690151 1 RES2 Resistor- Refrigeration Circuit #2 1000 OHM 044690110 1 RES3 Resistor- Freezestat FS1 1000 OHM 044690110 1 RES4 Resistor- OAE 1500 OHM 044690151 1 RES6,7,8 Resistor- SPS1, SPS2, SPS3 500 OHM 044690146 1/switch Switches- Control HS1 Switch- Electric Heat Shutdown Code 04= E 001355000 1 S1 Switch- System On/Off Gas Heat Units with no UV Lights DPST/15A 018446400 1 Gas Heat Units with UV Lights 4PST/30A 033536700 1 Electric, Steam, HW, No Heat with no UV Lights SPST/20A 001355000 1 Electric, Steam, HW, No Heat with UV Lights DPST/15A 018446400 1 S4 Switch- Inverter Bypass On/Off DPST/15A 018446400 1 S7 Switch- Local On/Auto/Off to Controller SPDT/15A 193412101 1 Transformers T2, 3 Transformer- Control 120- 24V 349937303 1 T7 Transformer- Hot Gas Reheat 120- 24V 349937303 1 Receptacle REC1 Receptacle 039003600 1 Duct Hi Limit and Static Pressure Sensors DHL Duct Hi Limit Switch 065493801 1 SPS1, 2 Pressure Transducer- Duct Sensor 3 910117462 1 Pressure Transducer- Space Sensor 3 910117463 1 Snubber, Pressure Transducer (optional; field installed) 1 910181702 21 Not Shown on diagram. 2 Quantity varies depending upon unit options selected.3 SPS1 Duct Sensor Code 13= 1, 2, 3. SPS2 Duct Sensor Code 13= 2. SPS2 Space Sensor Code 13= 3, 4.

Page 175: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 175

Sch. Part Part Qty. Sym. Description Number Relays R12 Relay- Condenser Fan 349934724 1 R14 Relay- Condenser Fan 349934724 1 R20 Relay- Heat 349934724 1 R25 Relay- Gas Heat, Start Supply Fan Inverter Code 14= 1,2,3,5,6,7 349934724 1 R63 Relay- Duct Hi Limit Units with Supply Fan Inverter Code 14= 1, 3, 6 0 OR 1 Duct Sensor Code 13= Y, 1 349934724 1 2 Duct Sensors Code 13= 2 349934923 1 1 Duct & Space Sensor OR 1 Space Sensor Code 13= 3, 4 349934923 1 DHL Sensor Code 13= 5 349934921 1 Units with Supply & Return Fan Inverters Code 14= 2, 5, 7 Vars. Code 13= 1, 2, 3, 4, Y 349934923 1 R70, 90-92 Relays- Specials/Digital Compressor 349934724 vars. R81- 88 Relays- Smoke 4P/6A/24V 193413601 vars. Time Delays TD20 Time Delay 20 Second 028210106 1 TD29 Time Delay, Coil Splitter 349983901 1 Terminal Blocks TB1 Terminal Block 349930641 1

TB35 Terminal Block Assy. 910150442 1 TB36 Terminal Block Assy. 404148501 1 Sensors 3

ZNT1 Sensor, Digital- Zone Temperature w/ Tenant O/R & Setpoint Adj. 4 910143408 1 Sensor- Zone Temperature w/ Tenant Override 4 113117701 1 Sensor- Zone Temp. w/ Tenant Override & Remote Setpoint Adj. 2, 4 113117801 1 SHS1 Sensor, Humidity Duct Mounted 12/16 & Earlier 067295001 Sensor, Humidity Duct Mounted 1/17 & Later 910190890 Sensor, Humidity Wall Mounted 067294901 DAT Sensor- Discharge Air Temperature 193414602 1 EFT Sensor- Entering Air Temperature 193414602 1 OAT Sensor- Outside Air Temperature 193414602 1 RAT Sensor- Return Air Temperature 193414602 1 EAT Sensor- Exhaust Air Temperature 193414602 1 LAT Sensor- Leaving Air Temperature 193414602 1

Section N- Main Control Box Control Panel

MicroTech III Units with Controller (Code 12= *E, *F, *W): (04/2013 & Later)Components, Continued

10

50

1456

22

68

30

86

2680

°F

°C

62 7418

ZNT1 Sensor910143408

ZNT1 Sensor113117701

ZNT1 Sensor113117801

1 Varies depending on unit options. Part number is for one individual section. Ground block is p/n 349930647.2 SCC Units only (Code 12= *F).3 Not Shown on diagram.4 In late 2013, Digital Room Sensor p/n 910143408 was added as the preferred option. The other Zone Temperature Sensors

are still available as options. For positive p/n identification, refer to the drawings below..

Page 176: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 176

See Control Panel

See C

ontrol Panel

Section N- Main Control BoxPower Panel: (03/2013 & Earlier)

Diagram 1

See

Con

trol

Pan

el

1 The above diagram shows a typical Power Panel layout and is to be used for reference only. Specific unit configuration may differ depending upon unit size and options selected.

PL1

- PL4

3 Pl

ugs

Page 177: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 177

Sch. Part Part Voltage Sym. Description Number 208V 230V 460V 575V Terminal Blocks TB1 Terminal Block 349930641 1 1 1 1

TB2, 3, 4, 7 Terminal Block 349930621 2 2 2 2

Transformer- Main 3

T1 Transformer- Main Control Electric, Hydronic, No Heat Code 04= E,S,W,Y Units without UV Lights 038253974 1 Units without UV Lights 038253956 1 1 Units without UV Lights 038253983 1 Units with UV Lights Code 17 (2nd digit)= 1- 8 038253975 1 Units with UV Lights Code 17 (2nd digit)= 1- 8 038253957 1 1 Units with UV Lights Code 17 (2nd digit)= 1- 8 038253984 1 Gas Heat Code 04= A Units without UV Lights 038253975 1 Units without UV Lights 038253957 1 1 Units without UV Lights 038253984 1 Units with UV Lights Code 17 (2nd digit)= 1- 8 038253976 1 Units with UV Lights Code 17 (2nd digit)= 1- 8 038253958 1 1 Units with UV Lights Code 17 (2nd digit)= 1- 8 038253985 1 Fuses- T1 F1A, B Fuse- T1 Transformer, Primary Electric, Hydronic, No Heat Code 04= E,S,W,Y Units without UV Lights 300042152 2 Units without UV Lights 049759816 2 Units without UV Lights 049759811 2 Units without UV Lights 049759814 2 Units with UV Lights Code 17 (2nd digit)= 1- 8 349937134 2 Units with UV Lights Code 17 (2nd digit)= 1- 8 349937133 2 Units with UV Lights Code 17 (2nd digit)= 1- 8 049759814 2 Units with UV Lights Code 17 (2nd digit)= 1- 8 349937125 2 Gas Heat Code 04= A Units without UV Lights 349937134 2 Units without UV Lights 349937133 2 Units without UV Lights 049759814 2 Units without UV Lights 349937125 2 Units with UV Lights Code 17 (2nd digit)= 1- 8 349937135 2 2 Units with UV Lights Code 17 (2nd digit)= 1- 8 049759816 2 Units with UV Lights Code 17 (2nd digit)= 1- 8 349937130 2 F1C Fuse- T1 Transformer 349937036 4 1 1 1 1 Fuse- T1 Transformer 349937035 4 1 1 1 1 Fuse- T1 Transformer 042753121 4 1 1 1 11 Varies depending on unit options. Part number is for one individual section. Ground block is p/n 349930647. Jumpers are p/n

349930945 (TB1A:5), 349930943 (TB1B:14), 349930942 (TB1C:20, TB1D:25 & TB1E:30).2 Varies depending on unit options. Part number is for one individual section. Ground block is p/n 349930627.3 T1 Transformers use Fuse Puller Kit p/n 349955801 & Cover Kit p/n 349955901.4 Fuse depends on heat type and presence of UV lights. 349937036= Gas Heat Unit w/ UV lights; 349937035= Gas Heat Unit with

no UV lights OR Non-Gas Heat Unit with UV lights; 042753121= Non- Gas Heat Units with no UV lights.

Section N- Main Control BoxPower Panel: (03/2013 & Earlier)

Terminal Blocks, T1 Transformer, Fuses

Page 178: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 178

Sch. Part Part Voltage Sym. Description Number 208V 230V 460V 575V Fuses F2,F3, F5 Fuses Fuse Block 023780223 1/fuse 1/fuse 1/fuse 1/fuse Fuse Cover 349938227 1/fuse 1/fuse 1/fuse 1/fuse F2 Fuse- 2000+VA transformer 349937035 1 1 1 1 F3 Fuse- Blower Motor Code 04= A 349937035 1 1 1 1 F5 Fuse- UV Lights Code 17 (2nd digit)= 1- 8 349937032 1 1 1 1 Ground Fault Code 17 [2nd digit]= G, B, C, D, K GFR1 Ground Fault Relay- SPDT 349937502 1 1 1 1 GFS1 Ground Fault Sensor 349937407 1 1 1 1 Phase Voltage Code 17 [2nd digit]= P, A, C, D, H, J, K PVM1, 2 Phase Voltage Monitor 112022001 2 2 2 Phase Voltage Monitor 112022002 2 Power Blocks 1

PB1 Power Block- Main Code 11= P1, Q1 Power Block, Non- Electric Heat Units- 175A 030372776 1 1 1 1 Power Block, Electric Heat Units- 175A 030372780 1 1 1 1 Lug- 175A Block 349938001 1 1 1 1 Power Block, Non- Electric Heat Units- 255A 030372778 1 1 1 1 Lug- 255A Block 349938001 1 1 1 1 Power Block, Non- Electric Heat Units- 380A 030372779 1 1 1 1 Power Block, Electric Heat- 380A 1 030372782 1 1 1 1 Lug- 380A Block 349938001 1 1 1 1 Power Block, Non- Electric Heat Units- 620A 030372702 1 1 1 1 Cover- 620A Block 349938345 3 3 3 3 Lug- 620A Block 349938002 1 1 1 1 Power Block, Non- Electric Heat Units- 760A 030372760 1 1 1 1 Power Block, Electric Heat Units, 208/230V- 760A 030372772 1 1 Power Block, Electric Heat Units, 460/575V- 760A 030372760 1 1 Cover- 760A Block 349938345 3 3 3 3 Lug- 760A Block 349938003 1 1 1 1 Power Block, Non- Electric Heat Units- 840A 030372724 1 1 1 1 Cover- 840A Block 349938345 3 3 3 3 Lug- 840A Block 349938003 1 1 1 1 PB11 Power Block- Power Distribution Code 04= E 20, 40 KW Electric Heat 030372777 1 1 1 1 60, 80, 100, 120 KW Electric Heat 030372785 1 1 60, 80, 100, 120 KW Electric Heat 030372777 1 1 140, 160, 180, 200, 220, 240 KW Electric Heat 030372785 1 1 PB10 Power Block- Supply Fan Code 15= F 030372776 1 1 1 1 PB20 Power Block- Return Fan Code 15= F 030372776 1 1 1 11 Any of the listed parts may be used, depending on unit options. Check the installed part to verify, use the Distributor Tools BOM

Search function on the Daikin Parts website, or contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified.

Section N- Main Control BoxPower Panel: (03/2013 & Earlier)

Fuses, Ground Fault Protection, Phase Protection (PVM1, 2), Power Supply, Power Blocks

Page 179: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 179

Sch. Part Part Voltage Sym. Description Number 208V 230V 460V 575V Disconnect Switch 1

DS1 Disconnect Switch- Main Code 11= A2 Switch- 100A RPS 349935125 1 1 1 1 Switch- 100A RFS 2 349935121 1 1 1 1 Shaft, Mod 349962201 6 6 6 6 Handle w/ Operating Mechanism 349935521 1 1 1 1 Ground Lug 349938001 1 1 1 1 Switch- 150A RPS 349935126 1 1 1 1 Switch- 150A RFS 2 349935122 1 1 1 1 Shaft, Mod 349962202 6 6 6 6 Handle w/ Operating Mechanism 349935532 1 1 1 1 Ground Lug 349938001 1 1 1 1 Switch- 250A RPS 349935226 1 1 1 1 Switch- 250A RFS 2 349935222 1 1 1 1 Shaft, Mod 349962202 6 6 6 6 Handle w/ Operating Mechanism 349935532 1 1 1 1 Ground Lug 349938001 1 1 1 1 Switch- 400A RPS 349935325 1 1 1 1 Switch- 400A RFS 2 349935321 1 1 1 1 Shaft, Mod 349962203 6 6 6 6 Handle w/ Operating Mechanism 349935621 1 1 1 1 Ground Lug 349938002 1 1 1 1 Switch- 600A 193438002 11 1 1 1 1 Shaft, Mod 349962223 12 6 6 6 6 Handle w/ Operating Mechanism 193437901 1 1 1 1 Ground Lug 349938002 1 1 1 1 Plugs 10 3 4 Pin Plug 349930201 varies varies varies varies 4 6 Pin Plug 349930403 varies varies varies varies 5 12 Pin Plug 349930405 varies varies varies varies 6 3 Pin Cap Kit 349930501 varies varies varies varies 7 6 Pin Cap Kit 349930503 varies varies varies varies 8 9 Pin Cap Kit 349930504 varies varies varies varies 9 15 Pin Cap Kit 349930506 varies varies varies varies1 Any of the listed disconnects may be used, depending on unit options. Check the installed part to verify, use the Distributor Tools BOM

Search function on the Daikin Parts website, or contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified.

2 The listed disconnects apply to RFS units with Steam Heat, HW Heat, Gas Heat OR No Heat. RFS units with Electric Heat use the same Disconnects as RPS units.

3 Used for PL1, PL, 2, PL3, PL4, PL5, PL6, PL22,PL23, PL24, PL37, PL38.4 Used with strain relief (p/n 300041173) & 6 pin cap kit (p/n 349930503). Used for PL20, PL21.5 Used for PL11, PL12, PL25, PL26, PL27, PL28, PL29, PL30 (PL11 & 12 also use strain relief p/n 300041175 & cap kit p/n 349930505).6 Used for PL16, PL17, PL31, PL32, PL33, PL34, PL39, PL40, PL41, PL42.7 Used for PL9, PL10.8 Used for PL18, PL19, PL35, PL36, PL43.9 Used for PL7, PL8.10 All possible plugs used are listed. Check actual unit to verify which plug is required.11 The original type "N" disconnect is obsolete 3/10. Due to size differences, minor field modifications may be required for proper installation.12 Only for use with new style disconnect for units built after 3/10. If replacing the handle assembly for a unit built before 3/10, use

handle p/n: 349935631.

Section N- Main Control BoxPower Panel: (03/2013 & Earlier)

Disconnect Switches, Plugs

Page 180: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 180

Sch. Part Part Voltage Sym. Description Number 208V 230V 460V 575V Circuit Breakers CB10 Circuit Breaker- Supply Fan CB20 Circuit Breaker- Return Fan Motor HP= 1, 1.5, 2, 3 349939621 1 1 1 Motor HP= 1, 1.5, 2, 3, 5, 7.5, 10 349939601 1 Motor HP= 5 349939622 1 1 Motor HP= 5, 7.5 349939621 1 Motor HP= 7.5 349939624 1 1 Motor HP= 10 349939626 1 1 Motor HP= 10 349939622 1 Motor HP= 15 349939629 1 1 Motor HP= 15 349939624 1 Motor HP= 15, 20 349939604 1 Motor HP= 20 349939631 1 Motor HP= 20 349939630 1 Motor HP= 20, 25 349939626 1 Motor HP= 25 349939632 1 Motor HP= 25 349939631 1 Motor HP= 25 349939606 1 CB60 Circuit Breaker- Heat Recovery Wheel 349939621 1 1 1 Circuit Breaker- Heat Recovery Wheel 349939601 1

Section N- Main Control BoxPower Panel: (03/2013 & Earlier)

Circuit Breakers

Page 181: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 181

MMP

LinkContactor

Front Mtd.Aux. Contact

Aux. Contact3

3B1

3E

3D

MMP10 & M10 Link DetailMMP20 & M20 Link Detail

1- 7.5 HP Motors- All Voltages10 HP Motor- 230/460/575V15, 20 HP Motor- 460/575V

25 HP Motor- 575V

MMP10 & M10 Link DetailMMP20 & M20 Link Detail

10HP Motor- 208V15HP Motor- 208/230V20 HP Motor- 208/230V25 HP Motor- 230/460V

Short Circuit Alarm

3D

MMPFront MountedAux. Contact

3E

Contactor

1

3

MMP 3

Contactor

1

Trip Indicator

Alarm3F

Lug 3G

MMP10 & M10 Link DetailMMP20 & M20 Link Detail

25 HP Motor- 208V

Section N- Main Control BoxPower Panel: (03/2013 & Earlier)

Supply MMP10 & M10 Fan Contactor and Return MMP20 & M20 Fan Contactor

Diagrams

NOTE: The diagrams show ALL possible parts. Not every part shown applies to every unit size/voltage combination.

Page 182: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 182

Voltage Ref. Sch. Part Part No. Sym. Description Number 1 M10, 20 Contactor- Supply (M10) OR Return (M20) Fan 349932121 1 1 1 1 3 MMP10, 20 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934048 1 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934046 1 1 3B Link 349932922 1 1 1 1 3E Front Mtd. Aux. Contact- 1NO OR 1NC 349933821 1 1 1 1

208V

230V

460V

575V

1 HP Motor- Code 22 OR 32= E*Y

Voltage Ref. Sch. Part Part No. Sym. Description Number 1 M10, 20 Contactor- Supply (M10) OR Return (M20) Fan 349932121 1 1 1 1 3 MMP10, 20 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934049 1 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934047 1 1 3B Link 349932922 1 1 1 1 3E Front Mtd. Aux. Contact- 1NO OR 1NC 349933821 1 1 1 1

1.5 HP Motor- Code 22 OR 32= F*Y

208V

230V

460V

575V

Voltage Ref. Sch. Part Part No. Sym. Description Number 1 M10, 20 Contactor- Supply (M10) OR Return (M20) Fan 349932121 1 1 1 1 3 MMP10, 20 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934050 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934049 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934048 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934047 1 3B Link 349932922 1 1 1 1 3E Front Mtd. Aux. Contact- 1NO OR 1NC 349933821 1 1 1 1

208V

230V

460V

575V

2 HP Motor- Code 22 OR 32= G*Y

Section N- Main Control BoxPower Panel: (03/2013 & Earlier)

Supply MMP10 & M10 Fan Contactor and Return MMP20 & M20 Fan Contactor

Components

Page 183: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 183

Voltage Ref. Sch. Part Part No. Sym. Description Number 1 M10, 20 Contactor- Supply (M10) OR Return (M20) Fan 349932122 1 1 Contactor- Supply (M10) OR Return (M20) Fan 349932121 1 1 3 MMP10, 20 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934051 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934050 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934049 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934048 1 3B Link 349932922 1 1 1 1 3E Front Mtd. Aux. Contact- 1NO OR 1NC 349933821 1 1 1 1

208V

230V

460V

575V

3 HP Motor- Code 22 OR 32= H*Y

Voltage Ref. Sch. Part Part No. Sym. Description Number 1 M10, 20 Contactor- Supply (M10) OR Return (M20) Fan 349932123 1 1 Contactor- Supply (M10) OR Return (M20) Fan 349932121 1 1 3 MMP10, 20 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934052 1 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934050 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934049 1 3B Link 349932922 1 1 1 1 3E Front Mtd. Aux. Contact- 1NO OR 1NC 349933821 1 1 1 1

208V

230V

460V

575V

5 HP Motor- Code 22 OR 32= J*Y

Voltage Ref. Sch. Part Part No. Sym. Description Number 1 M10, 20 Contactor- Supply (M10) OR Return (M20) Fan 349932321 1 1 Contactor- Supply (M10) OR Return (M20) Fan 349932122 1 Contactor- Supply (M10) OR Return (M20) Fan 349932121 1 3 MMP10, 20 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934054 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934053 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934051 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934050 1 3B Link 349932922 1 1 1 1 3E Front Mtd. Aux. Contact- 1NO OR 1NC 349933821 1 1 1 1

208V

230V

460V

575V

7.5 HP Motor- Code 22 OR 32= K*Y

Section N- Main Control BoxPower Panel: (03/2013 & Earlier)

Supply MMP10 & M10 Fan Contactor and Return MMP20 & M20 Fan Contactor

Components, Continued

Page 184: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 184

Voltage Ref. Sch. Part Part No. Sym. Description Number 1 M10, 20 Contactor- Supply (M10) OR Return (M20) Fan 349932521 1 Contactor- Supply (M10) OR Return (M20) Fan 349932322 1 Contactor- Supply (M10) OR Return (M20) Fan 349932123 1 Contactor- Supply (M10) OR Return (M20) Fan 349932122 1 3 MMP10, 20 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934147 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934055 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934052 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934051 1 3B Link 349932922 1 1 1 3E Front Mtd. Aux. Contact- 1NO OR 1NC 349933821 1 1 1 1

208V

230V

460V

575V

10 HP Motor- Code 22 OR 32= L*Y

Voltage Ref. Sch. Part Part No. Sym. Description Number 1 M10, 20 Contactor- Supply (M10) OR Return (M20) Fan 349932522 1 1 Contactor- Supply (M10) OR Return (M20) Fan 349932321 1 Contactor- Supply (M10) OR Return (M20) Fan 349932123 1 3 MMP10, 20 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934148 1 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934053 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934052 1 3B Link 349932922 1 1 3E Front Mtd. Aux. Contact- 1NO OR 1NC 349933821 1 1 1 1

208V

230V

460V

575V

15 HP Motor- Code 22 OR 32= M*Y

Section N- Main Control BoxPower Panel: (03/2013 & Earlier)

Supply MMP10 & M10 Fan Contactor and Return MMP20 & M20 Fan Contactor

Components, Continued

Page 185: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 185

Voltage Ref. Sch. Part Part No. Sym. Description Number 1 M10 Contactor- Supply Fan 349932621 1 1 Contactor- Supply Fan 349932521 1 Contactor- Supply Fan 349932322 1 3 MMP10 MMP- Supply Fan 349938606 1 MMP- Supply Fan 349934149 1 MMP- Supply Fan 349934147 1 MMP- Supply Fan 349934054 1 3B Link 349932922 1 3E Front Mtd. Aux. Contact- 1NO OR 1NC 349933821 1 1 1 3F Trip Indicator Interlock 349938701 1 3G Lug (3 per kit) 349938801 2

208V

230V

460V

575V

25 HP Motor- Code 32= P*Y 1

Voltage Ref. Sch. Part Part No. Sym. Description Number 1 M10, 20 Contactor- Supply (M10) OR Return (M20) Fan 349932523 1 1 Contactor- Supply (M10) OR Return (M20) Fan 349932322 1 Contactor- Supply (M10) OR Return (M20) Fan 349932321 1 3 MMP10, 20 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934149 1 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934055 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 349934053 1 3B Link 349932922 1 1 3E Front Mtd. Aux. Contact- 1NO OR 1NC 349933821 1 1 1 1

208V

230V

460V

575V

20 HP Motor- Code 22 OR 32= N*Y

Section N- Main Control BoxPower Panel: (03/2013 & Earlier)

Supply MMP10 & M10 Fan Contactor and Return MMP20 & M20 Fan Contactor

Components, Continued

1 A 25HP Supply Fan Motor is only available when Code 31= 24**. A 25HP Motor is not available for Return Fan applications.

Page 186: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 186

Section N- Main Control BoxPower Panel: (03/2013 & Earlier)

Compressor MMP1, MMP2 and Contactor M1, M2Unit Size 015D

MMP

3 4or

Contactor

1 or 2

Front-Mounted Aux. Contact

4E3E or

Link

4B3B or

015 Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors 1 M1 Contactor- Compressor #1 349932322 1 1 Contactor- Compressor #1 349932321 1 1 1E Front Mtd. Aux. Contact- 1NO AND 1NC 349931923 1 1 1 1 2 M2 Contactor- Compressor #2 349932322 1 1 Contactor- Compressor #2 349932321 1 1 2E Front Mtd. Aux. Contact- 1NO AND 1NC 349931923 1 1 1 1 Compressor MMP's & Parts 3 MMP1 Manual Motor Protector- Compressor #1 349934055 1 1 Manual Motor Protector- Compressor #1 349934051 1 1 3A Spacer 349906501 1 1 1 1 3B Link 349932922 1 1 1 1 3E Front Mtd. Aux. Contact- 1NO OR 1NC 349933821 1 1 1 1 4 MMP2 Manual Motor Protector- Compressor #2 349934055 1 1 Manual Motor Protector- Compressor #2 349934051 1 1 4A Spacer 349906501 1 1 1 1 4B Link 349932922 1 1 1 1 4E Front Mtd. Aux. Contact- 1NO OR 1NC 349933821 1 1 1 1

208V

230V

460V

575V

Front-Mounted Aux. Contact

2E1E or

Spacer

3A or 4A

Page 187: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 187

MMP

Link

Contactor

Front-Mounted Aux. Contact

3

4B

1

4E

MMP1 & M1 or MMP3 & M3 Link Detail- All VoltagesMMP2 & M2 Link Detail- 460/575V, Unit Size 025

MMP 4

4E

Contactor 2

MMP2 & M2 Link Detail- 208/230V, Unit Sizes 025, 030 MMP2 & M2 Link Detail- 460/575, Unit Size 030

4or

or 2

3E or

3B or

Front-Mounted Aux. Contact

Section N- Main Control BoxPower Panel: (03/2013 & Earlier)

Compressor MMP1, 2, 4 and Contactor M1, 2, 4Unit Sizes 020- 031D

Unit Size 020, 021 025, 026 030, 031 Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors 1 M1 Contactor 349932522 1 1 Contactor 349932321 1 1 1 1 Contactor 349932523 1 1 1 1 Contactor 349932322 1 1 2 M2, 4 Contactor 349932321 2 2 Contactor 349932123 2 2 2 2 2 2 Contactor 349932321 2 2 Contactor 349932322 2 2 Comp. MMP's & Parts 3 MMP1 Manual Motor Protector 349934148 1 1 Manual Motor Protector 349934053 1 1 1 Manual Motor Protector 349934052 1 1 Manual Motor Protector 349934149 1 1 1 1 Manual Motor Protector 349934055 1 3B Link- MMP 349932922 1 1 1 1 1 1 3E Aux.- Front Mounted 349933821 1 1 1 1 1 1 1 1 1 1 1 1 4 MMP2, 4 Manual Motor Protector 349934053 2 2 Manual Motor Protector 349934050 2 2 2 2 Manual Motor Protector 349934055 2 2 2 2 Manual Motor Protector 349934054 Manual Motor Protector 349934051 2 2 4B Link- MMP 349932922 1 1 1 1 1 1 4E Aux.- Front Mounted 349933821 1 1 1 1 1 1 1 1 1 1 1 1

208V

230V

460V

575V

208V

230V

460V

575V

208V

230V

460V

575V

Page 188: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 188

MMP1 & M1 Link Detail- All VoltagesMMP3 & M3 Link Detail- All Voltages

MMP2 & M2 Link Detail- 460/575VMMP4 & M4 Link Detail- 460/575V

MMP2 & M2 Link Detail- 208/230VMMP4 & M4 Link Detail- 208/230V

MMP

Link

Contactor

Front-Mounted Aux. Contact

3

4B

1

4E

MMP 4

4E

Contactor 2

4or

or 2

3E or

3B or

Front-Mounted Aux. Contact

Section N- Main Control BoxPower Panel: (03/2013 & Earlier)

Compressor MMP1 thru 4 and Contactor M1 thru 4Unit Sizes 035- 042D

Unit Size 035 040 042Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors 1 M1, 3 Contactor 349932521 2 2 2 2 2 2 Contactor 349932321 2 2 2 2 2 2 2 M2, 4 Contactor 349932521 2 2 2 2 2 2 Contactor 349932321 2 2 2 2 2 2 Comp. MMP's & Parts 3 MMP1, 3 Manual Motor Protector 349934147 2 2 2 2 2 2 Manual Motor Protector 349934053 2 2 2 2 2 Manual Motor Protector 349934051 2 3B Link- MMP 349932922 1 1 1 1 1 1 3E Aux.- Front Mounted 349933821 1 1 1 1 1 1 1 1 1 1 1 1 4 MMP2, 4 Manual Motor Protector 349934053 2 2 Manual Motor Protector 349934050 2 2 2 2 Manual Motor Protector 349934055 2 2 2 2 Manual Motor Protector 349934051 2 2 4B Link- MMP 349932922 1 1 1 1 1 1 4E Aux.- Front Mounted 349933821 1 1 1 1 1 1 1 1 1 1 1 1

208V

230V

460V

575V

208V

230V

460V

575V

208V

230V

460V

575V

Page 189: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 189

MMP & Contactor Detail

MMP

Link

Contactor

8

8A

7 Spacer7A

Section N- Main Control BoxPower Panel: (03/2013 & Earlier)

Condenser Fan Contactors, MMPs, & Fusing

SpeedTrol Fusing DetailF11 OR F21

Fuse Block

Puller

Fuse

9B

9A 9

Adapter

9C

Unit Size Ref. Sch. Part Part 015 020 025 026 030 035 040 No. Sym Description Number 016 021 031 040 042 Fan Contactor & Spacer 7 M11- 22 FanTrol Code 47= 1, 3 349932121 2 2 2 2 4 4 4 SpeedTrol Code 47= 2, 4 349932121 2 2 2 7A Spacer 349906501 2 2 2 2 4 4 4 8 MMP11- 22 MMP- Condenser Fan & Link FanTrol Code 47= 1, 3 208/230V Code 47= 1, 3 349934049 2 2 2 2 4 4 4 460V Code 47= 1 349934047 2 2 2 2 4 4 4 575V Code 47= 3 349934046 2 2 2 2 4 4 4 SpeedTrol Code 47= 2, 4 208/230V Code 47= 2 349934049 2 2 2 460V Code 47= 2 349934048 2 2 2 460V Code 47= 4 349934047 2 2 2 575V Code 47= 2 349934047 2 2 2 8A Link 349932922 2 2 2 2 4 4 4

Units w/o Modulating Hot Gas Reheat Code 54= YY SpeedTrol Fusing Code 47= 2 9 FB11, 21 Fuse Block 023780232 2 2 2 2 2 2 2 9A F11, F21 Fuse 208V 7A 349937127 6 6 6 6 6 6 6 460V 3.5A 049759820 6 6 6 6 6 6 6 575V 3A 049759809 6 6 6 6 6 6 6 9B Fuse Cover/Puller 349938227 6 6 6 6 6 6 6 9C DIN Rail Adapter 349938412 4 4 4 4 4 4 4 SpeedTrol Fusing Code 47= 4 9 FB11, 21 Fuse Block 023780232 2 2 2 2 2 2 2 9A F11, F21 Fuse 460V 2.5A 049759808 6 6 6 6 6 6 6 9B Fuse Cover/Puller 349938227 6 6 6 6 6 6 6 9C DIN Rail Adapter 349938412 4 4 4 4 4 4 4

Page 190: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 190

Section N- Main Control BoxPower Panel: (03/2013 & Earlier)

Condenser Fan Contactors, MMPs, & Fusing, Continued

Unit Size Ref. Sch. Part Part 015 020 025 026 030 035 040 No. Sym. Description Number 016 021 031 040 042 Units w/ Modulating Hot Gas Reheat Code 54= BM MHGR Fusing Code 47= 1 9 FB21 Fuse Block 023780232 1 1 1 1 1 1 1 9B Fuse Cover/Puller 349938227 3 3 3 3 3 3 3 9A F21 Fuse 208V 7A 349937127 3 3 3 3 3 3 3 460V 3.5A 049759820 3 3 3 3 3 3 3 575V 3A 049759809 3 3 3 3 3 3 3 9C DIN Rail Adapter 349938412 2 2 2 2 2 2 2 MHGR Fusing Code 47= 2 9 FB11, 21 Fuse Block 023780232 2 2 2 2 2 2 2 9B Fuse Cover/Puller 349938227 6 6 6 6 6 6 3 9A F11, 21 Fuse 208V 7A 349937127 6 6 6 6 6 6 6 460V 3.5A 049759820 6 6 6 6 6 6 6 9C DIN Rail Adapter 349938412 4 4 4 4 4 4 4

Page 191: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 191

Heat Recovery Control Type 100% OA Low Flow 100% OA HI Flow Economizer Code 20= 1E Code 20= 2E Code 20= 3E

Ref. Sch. Part Part No. Sym. Description Number Heat Wheel Contactor 7 M60 Contactor 349932121 1 1 1 1 1 1 1 1 1 M61 Contactor 349932121 1 1 1 7A Spacer 349906501 1 1 1 2 2 2 1 1 1

Heat Wheel MMP 8 MMP60 Manual Motor Protector 349934048 1 1 1 Manual Motor Protector 349934046 1 1 1 1 1 1 MMP61 Manual Motor Protector 349934048 1 Manual Motor Protector 349934046 1 1 8B Link- MMP 349932922 1 1 1 2 2 2 1 1 1

208/

230V

460V

575V

208/

230V

460V

575V

208/

230V

460V

575V

Section N- Main Control BoxPower Panel: (03/2013 & Earlier)

Energy Recovery Wheel MMP60, 61 & Contactor M60, 61: Code 24= YDiagram and Components

MMP

Link

Contactor

8

8A

7Spacer7A

Page 192: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 192

See Control Panel

See C

ontrol Panel

Section N- Main Control BoxPower Panel: (04/2013 & Later)

Diagram 1

1 The above diagram shows a typical Power Panel layout and is to be used for reference only. Specific unit configuration may differ depending upon unit size and options selected.

See

Con

trol

Pan

el

PL1

- PL4

3 Pl

ugs

Page 193: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 193

Sch. Part Part Voltage Sym. Description Number 208V 230V 460V 575V Terminal Blocks TB1 Terminal Block 349930641 1 1 1 1

TB2, 3, 4,7 Terminal Block 349930621 2 2 2 2

Transformer- Main Control T1 Transformer Electric, Hydronic, No Heat Code 04= E,S,W,Y Units without UV Lights Code 23= Y**** Unit Sizes 015- 042D 1000VA 099477205 1 Unit Sizes 015- 042D 1000VA 099477105 1 1 Unit Sizes 015- 042D 1000VA 099477305 1 Units with UV Lights Code 23= U**** Unit Sizes 015- 035D 1500VA 099477206 1 Unit Sizes 015- 035D 1500VA 099477106 1 1 Unit Sizes 015- 035D 1500VA 099477306 1 Unit Size 042D 2000VA 099477207 1 Unit Size 042D 2000VA 099477107 1 1 Unit Size 042D 2000VA 099477307 1 T1 Transformer Gas Heat Code 04= A Units without UV Lights Code 23= Y**** Unit Sizes 015- 042D 1500VA 099477206 1 Unit Sizes 015- 042D 1500VA 099477106 1 1 Unit Sizes 015- 042D 1500VA 099477306 1 Units with UV Lights Code 23= U**** Unit Sizes 015- 035D 1500VA 099477206 1 Unit Sizes 015- 035D 1500VA 099477106 1 1 Unit Sizes 015- 035D 1500VA 099477306 1 Unit Size 042D 2000VA 099477207 1 Unit Size 042D 2000VA 099477107 1 1 Unit Size 042D 2000VA 099477307 1 N/S Cover Kit, Terminal 099477602 1 1 1 1 N/S Cover Kit, Fuseholder 099477401 1 1 1 1 Fuses- T1 Transformer FU1A, B Fuse- T1 Transformer, Primary 3 2 2 2 2 FU1C Fuse- T1 Transformer, Secondary 3 1 1 1 1N/S= Not shown on diagram.1 Varies depending on unit options. Part number is for one individual section. Ground block is p/n 349930647. Jumpers are p/n

349930945 (TB1A:5), 349930943 (TB1B:14), 349930942 (TB1C:20, TB1D:25 & TB1E:30).2 Varies depending on unit options. Part number is for one individual section. Ground block is p/n 349930627.3 Use the Distributor Tools BOM Search function on the Daikin Parts website or contact Daikin Applied with model and serial number

information to ensure that the correct part(s) are identified.

Section N- Main Control BoxPower Panel: (04/2013 & Later)

Terminal Blocks, T1 Transformer, & Fuses

Page 194: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 194

Sch. Part Part Voltage Sym. Description Number 208V 230V 460V 575V Fuses F2, 3, 5 Fuses Fuse Block 023780223 1/fuse 1/fuse 1/fuse 1/fuse Fuse Cover 349938227 1/fuse 1/fuse 1/fuse 1/fuse F2 Fuse- 2000+VA transformer 349937035 1 1 1 1 F3 Fuse- Blower Motor Code 04= A 349937035 1 1 1 1 F5 Fuse- UV Lights Code 17 (2nd digit)= 1- 8 349937032 1 1 1 1 Ground Fault Code 17 [2nd digit]= G, B, C, D, K GFR1 Ground Fault Relay- SPDT 349937502 1 1 1 1 GFS1 Ground Fault Sensor 349937407 1 1 1 1 Phase Voltage Code 17 [2nd digit]= P, A, C, D, H, J, K PVM1, 2 Phase Voltage Monitor (12/16 & Earlier) 2 112022001 2 2 2 Phase Voltage Monitor (12/16 & Earlier) 2 112022002 2 Phase Voltage Monitor (2/17 & Later) 2 193599301 2 2 2 Phase Voltage Monitor (2/17 & Later) 2 193599303 2 - Socket, PVM (2/17 & Later) 2 193599401 2 2 2 2 Power Blocks 1

PB1 Power Block- Main Code 11= P1, Q1 Power Block, Non- Electric Heat Units- 175A 030372776 1 1 1 1 Power Block, Electric Heat Units- 175A 030372780 1 1 1 1 Lug- 175A Block 349938001 1 1 1 1 Power Block, Non- Electric Heat Units- 255A 030372778 1 1 1 1 Lug- 255A Block 349938001 1 1 1 1 Power Block, Non- Electric Heat Units- 380A 030372779 1 1 1 1 Power Block, Electric Heat- 380A 030372782 1 1 1 1 Lug- 380A Block 349938001 1 1 1 1 Power Block, Non- Electric Heat Units- 620A 030372702 1 1 1 1 Cover- 620A Block 349938345 3 3 3 3 Lug- 620A Block 349938002 1 1 1 1 Power Block, Non- Electric Heat Units- 760A 030372760 1 1 1 1 Power Block, Electric Heat Units, 208/230V- 760A 030372772 1 1 Power Block, Electric Heat Units, 460/575V- 760A 030372760 1 1 Cover- 760A Block 349938345 3 3 3 3 Lug- 760A Block 349938003 1 1 1 1 Power Block, Non- Electric Heat Units- 840A 030372724 1 1 1 1 Cover- 840A Block 349938345 3 3 3 3 Lug- 840A Block 349938003 1 1 1 1 PB11 Power Block- Power Distribution Code 04= E 20, 40 KW Electric Heat 030372777 1 1 1 1 60, 80, 100, 120 KW Electric Heat 030372785 1 1 60, 80, 100, 120 KW Electric Heat 030372777 1 1 140, 160, 180, 200, 220, 240 KW Electric Heat 030372785 1 1 PB10 Power Block- Supply Fan Code 15= F 030372776 1 1 1 1 PB20 Power Block- Return Fan Code 15= F 030372776 1 1 1 11 Any of the listed parts may be used, depending on unit options. Check the installed part to verify, use the Distributor Tools BOM

Search function on the Daikin Parts website, or contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified.

2 For units built 1/17 Check the installed part to verify, use the Distributor Tools BOM Search function on the Daikin Parts website, or contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified.

Section N- Main Control BoxPower Panel: (04/2013 & Later)

Fuses, Ground Fault Protection, Phase Protection (PVM1, 2), Power Supply, & Power Blocks

Page 195: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 195

Section N- Main Control BoxPower Panel: (04/2013 & Later)Disconnect Switches & Plugs

Sch. Part Part Voltage Sym. Description Number 208V 230V 460V 575V Disconnect Switch 1

DS1 Disconnect Switch- Main Switch- 100A 193444703 1 1 1 1 Handle 193422102 1 1 1 1 Shaft, 6 mm 2 300040562 1 1 1 1 Switch- 150A 193585101 1 1 1 1 Handle 193422102 1 1 1 1 Mechanism 193550801 1 1 1 1 Shaft, 6 mm 2 300040562 1 1 1 1 Lugs 4 193553301 1 1 1 1 Switch- 250A 193551601 1 1 1 1 Handle 193595701 1 1 1 1 Mechanism 193551001 1 1 1 1 Shaft, 10 mm 3 300040299 1 1 1 1 Lugs 4 193553801 1 1 1 1 Switch- 400A 193551701 1 1 1 1 Handle 193595701 1 1 1 1 Mechanism 193551001 1 1 1 1 Shaft, 10 mm 3 300040299 1 1 1 1 Lugs 4 193554001 1 1 1 1 Switch- 600A 193551801 1 1 1 1 Handle 193595701 1 1 1 1 Mechanism 193551001 1 1 1 1 Shaft, 10 mm 3 300040299 1 1 1 1 Lugs 4 193554101 2 2 2 2 Switch- 800A 193551901 1 1 1 1 Handle 193595701 1 1 1 1 Mechanism 193558201 1 1 1 1 Shaft, 10 mm 3 300040299 1 1 1 1 Lugs 4 193557001 2 2 2 2 Switch- 1000A 193552001 1 1 1 1 Handle 193588001 1 1 1 1 Mechanism 193550801 1 1 1 1 Shaft, 10 mm 3 300040299 1 1 1 1 Lugs 4 193555801 2 2 2 2 Plugs 12 5 4 Pin Plug 349930201 varies varies varies varies 6 6 Pin Plug 349930403 varies varies varies varies 7 12 Pin Plug 349930405 varies varies varies varies 8 3 Pin Cap Kit 349930501 varies varies varies varies 9 6 Pin Cap Kit 349930503 varies varies varies varies 10 9 Pin Cap Kit 349930504 varies varies varies varies 11 15 Pin Cap Kit 349930506 varies varies varies varies1 Disconnects are sized according to various unit specifications. Check the installed Switch to verify, use the Distributor Tools BOM

Search function on the Daikin Parts website, or contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified.

2 This shaft is 6 millimeters square (.236”) and 430 millimeters long (16.9”). It designed to be cut to the required length in the field.3 This shaft is 10 millimeters square (.394”) and 500 millimeters long (19.6”). It designed to be cut to the required length in the field.4 Three Lugs are included with each p/n.5 Used for PL1, PL, 2, PL3, PL4, PL5, PL6, PL22,PL23, PL24, PL37, PL38.6 Used with Strain Relief (p/n 300041173) & 6 pin Cap Kit (p/n 349930503). Used for PL20, PL21.7 Used for PL11, PL12, PL25, PL26, PL27, PL28, PL29, PL30 (PL11 & 12 also use Strain Relief p/n 300041175 & Cap Kit p/n 349930505).8 Used for PL16, PL17, PL31, PL32, PL33, PL34, PL39, PL40, PL41, PL42.9 Used for PL9, PL10.10 Used for PL18, PL19, PL35, PL36, PL43.11 Used for PL7, PL8.12 All possible Plugs used are listed. Check actual unit to verify which Plug is required.

Page 196: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 196

Section N- Main Control BoxPower Panel: (04/2013 & Later)

Supply MMP10 & M10 Fan ContactorReturn MMP20 & M20 Fan Contactor

Diagrams

MMP

3

Link 3B

Contactor

1

Front Mtd.Aux. Contact

2

MMP10 & M10 Link Detail1- 2 HP Motors- All Voltages

3, 5 HP Motors- 460/575V7.5 HP Motors- 575V

NOTE: The diagrams show ALL possible parts. Not every part shown applies to every unit size/voltage combination.

MMP10 & M10 Link Detail3, 5 HP Motors- 208/230V

7.5 HP Motors- 208/230/460V10 HP Motors- All Voltages

15, 20 HP Motors- 460V

MMP10 & M10 Link Detail20, 25 HP Motors- 208/230V

MMP

3

MMP

2

Contactor1

3MMP 3

Contactor1

MMP10 & M10 Link Detail15 HP Motors- 208/230/575V

20 HP Motors- 575V25 HP Motor- 460/575V

3EPhase Barrier

Spacer3A

3EPhase Barrier

Front Mtd.Aux. Contact

Link 3B

2Front Mtd.

Aux. Contact Link3B

Front Mtd.Aux. Contact

2

Contactor

1

Link 3B

3EPhase Barrier

Page 197: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 197

1 HP Motor- Code 22 OR 32= E*Y

1.5 HP Motor- Code 22 OR 32= F*Y

Section N- Main Control BoxPower Panel: (04/2013 & Later)

Supply and Return Fan Contactors, Circuit Breakers, & Fusing Components

Voltage Ref. Sch. Part Part No. Sym. Description Number 1 M10, 20 Contactor- Supply (M10) OR Return (M20) Fan 193534105 1 1 1 1 2 Front Mtd. Aux. Contact- 1NO AND 1NC 193543801 1 1 1 1 3 MMP10, 20 MMP- Supply (MMP10) OR Return (MMP20) Fan 193542909 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 193542908 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 193542905 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 193542904 1 3B Link 193545901 1 1 1 1 3E Phase Barrier 193545501 1 1 1 1 N/S VFD10, 20 VFD- Supply OR Return Fan 1 1 1 1 1 N/S CB10, 20 Circuit Breaker- Supply OR Return Fan 193550201 1 FB10, 20 Fuseblock- Supply OR Return Fan 023780232 1 1 1 Fuse- Supply OR Return Fan 5A 049759811 3 Fuse- Supply OR Return Fan 4A 349937123 3 Fuse- Supply OR Return Fan 2A 349937116 3 Fuse Cover/Puller- Supply OR Return Fan 349938227 2 2 2

208V

230V

460V

575V

N/S= Not Shown on Diagram. 1 Refer to the Inverter Section for VFD p/ns. Reference Code 15 for Inverter brand supplied.2 1 pc. PER Fuse.

Voltage Ref. Sch. Part Part No. Sym. Description Number 1 M10, 20 Contactor- Supply (M10) OR Return (M20) Fan 193534105 1 1 1 1 2 Front Mtd. Aux. Contact- 1NO AND 1NC 193543801 1 1 1 1 3 MMP10, 20 MMP- Supply (MMP10) OR Return (MMP20) Fan 193542911 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 193542910 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 193542907 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 193542906 1 3B Link 193545901 1 1 1 1 3E Phase Barrier 193545501 1 1 1 1 N/S VFD10, 20 VFD- Supply OR Return Fan 3 3 3 3 3 N/S CB10, 20 Circuit Breaker- Supply OR Return Fan 15A 193550201 1 FB10, 20 Fuseblock- Supply OR Return Fan 023780232 1 1 1 Fuse- Supply OR Return Fan 8A 049759814 3 Fuse- Supply OR Return Fan 7A 349937127 3 Fuse- Supply OR Return Fan 3A 049759809 3 Fuse Cover/Puller- Supply Fan 349938227 4 4 4

208V

230V

460V

575V

N/S= Not Shown on Diagram. 3 Refer to the Inverter Section for VFD p/ns. Reference Code 15 for Inverter brand supplied.4 1 pc. PER Fuse.

Page 198: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 198

3 HP Motor- Code 22 OR 32= H*Y

2 HP Motor- Code 22 OR 32= G*Y Voltage Ref. Sch. Part Part No. Sym. Description Number 1 M10, 20 Contactor- Supply (M10) OR Return (M20) Fan 193534106 1 Contactor- Supply (M10) OR Return (M20) Fan 193534105 1 1 1 2 Front Mtd. Aux. Contact- 1NO AND 1NC 193543801 1 1 1 1 3 MMP10, 20 MMP- Supply (MMP10) OR Return (MMP20) Fan 193542912 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 193542911 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 193542908 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 193542907 1 3B Link 193545901 1 1 1 1 3E Phase Barrier 193545501 1 1 1 1 N/S VFD10, 20 VFD- Supply OR Return Fan 1 1 1 1 1 N/S CB10, 20 Circuit Breaker- Supply OR Return Fan 15A 193550201 1 FB10, 20 Fuseblock- Supply OR Return Fan 023780232 1 1 1 Fuse- Supply OR Return Fan 10A 049759816 3 Fuse- Supply OR Return Fan 9A 349937130 3 Fuse- Supply OR Return Fan 4A 349937123 3 Fuse Cover/Puller- Supply Fan 349938227 2 2 2

208V

230V

460V

575V

Voltage Ref. Sch. Part Part No. Sym. Description Number 1 M10, 20 Contactor- Supply (M10) OR Return (M20) Fan 193592005 1 1 Contactor- Supply (M10) OR Return (M20) Fan 193534105 1 1 2 Front Mtd. Aux. Contact- 1NO AND 1NC 193543801 1 1 1 1 3 MMP10, 20 MMP- Supply (MMP10) OR Return (MMP20) Fan 193543007 1 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 193542910 1 1 3A Spacer 193545801 1 1 3B Link 193546001 1 1 Link 193545901 1 1 3E Phase Barrier 193545501 1 1 1 1 N/S VFD10, 20 VFD- Supply OR Return Fan 3 3 3 3 3 N/S CB10, 20 Circuit Breaker- Supply OR Return Fan 15A 193550201 1 FB10, 20 Fuseblock- Supply OR Return Fan 023780232 1 1 1 Fuse- Supply OR Return Fan 15A 349937133 3 Fuse- Supply OR Return Fan 10A 049759816 3 Fuse- Supply OR Return Fan 7A 349937127 3 Fuse Cover/Puller- Supply Fan 349938227 4 4 4

208V

230V

460V

575V

N/S= Not Shown on Diagram. 3 Refer to the Inverter Section for VFD p/ns. Reference Code 15 for Inverter brand supplied.4 1 pc. PER Fuse.

Section N- Main Control BoxPower Panel: (04/2013 & Later)

Supply and Return Fan Contactors, Circuit Breakers, & Fusing Components, Continued

N/S= Not Shown on Diagram. 1 Refer to the Inverter Section for VFD p/ns. Reference Code 15 for Inverter brand supplied.2 1 pc. PER Fuse.

Page 199: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 199

Section N- Main Control BoxPower Panel: (04/2013 & Later)

Supply and Return Fan Contactors, Circuit Breakers, & Fusing Components, Continued

Voltage Ref. Sch. Part Part No. Sym. Description Number 1 M10, 20 Contactor- Supply (M10) OR Return (M20) Fan 193537304 1 Contactor- Supply (M10) OR Return (M20) Fan 193592006 1 Contactor- Supply (M10) OR Return (M20) Fan 193534106 1 Contactor- Supply (M10) OR Return (M20) Fan 193534105 1 2 Front Mtd. Aux. Contact- 1NO AND 1NC 193543801 1 1 1 1 3 MMP10, 20 MMP- Supply (MMP10) OR Return (MMP20) Fan 193543009 1 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 193542912 1 1 3A Spacer 193545801 1 1 3B Link 193546001 1 1 Link 193545901 1 1 3E Phase Barrier 193545501 1 1 1 1 N/S VFD10, 20 VFD- Supply OR Return Fan 1 1 1 1 1 N/S CB10, 20 Circuit Breaker- Supply OR Return Fan 15A 193550201 1 FB10, 20 Fuseblock- Supply OR Return Fan 023780232 1 1 1 Fuse- Supply OR Return Fan 25A 349937136 3 Fuse- Supply OR Return Fan 20A 349937135 3 Fuse- Supply OR Return Fan 10A 049759816 3 Fuse Cover/Puller- Supply Fan 349938227 2 2 2

208V

230V

460V

575V

Voltage Ref. Sch. Part Part No. Sym. Description Number 1 M10, 20 Contactor- Supply (M10) OR Return (M20) Fan 193537304 1 1 Contactor- Supply (M10) OR Return (M20) Fan 193592005 1 Contactor- Supply (M10) OR Return (M20) Fan 193534106 1 2 Front Mtd. Aux. Contact- 1NO AND 1NC 193543801 1 1 1 1 3 MMP10, 20 MMP- Supply (MMP10) OR Return (MMP20) Fan 193543012 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 193543011 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 193543008 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 193542913 1 3A Spacer 193545801 1 1 1 3B Link 193546001 1 1 1 Link 193545901 1 3E Phase Barrier 193545501 1 1 1 1 N/S VFD10, 20 VFD- Supply OR Return Fan 3 3 3 3 3 N/S CB10, 20 Circuit Breaker- Supply OR Return Fan 15A 193550201 1 FB10, 20 Fuseblock- Supply OR Return Fan 193428502 1 1 Fuseblock- Supply OR Return Fan 023780232 1 Fuse- Supply OR Return Fan 35A 113085249 3 3 Fuse- Supply OR Return Fan 15A 349937133 3 Fuse Cover- Supply OR Return Fan 193428602 1 1 Fuse Cover/Puller- Supply Fan 349938227 4

208V

230V

460V

575V

N/S= Not Shown on Diagram. 3 Refer to the Inverter Section for VFD p/ns. Reference Code 15 for Inverter brand supplied.4 1 pc. PER Fuse.

5 HP Motor- Code 22 OR 32= J*Y

7.5 HP Motor- Code 22 OR 32= K*Y

N/S= Not Shown on Diagram. 1 Refer to the Inverter Section for VFD p/ns. Reference Code 15 for Inverter brand supplied.2 1 pc. PER Fuse.

Page 200: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 200

10 HP Motor- Code 22 OR 32= L*Y Voltage Ref. Sch. Part Part No. Sym. Description Number 1 M10, 20 Contactor- Supply (M10) OR Return (M20) Fan 193537305 1 1 Contactor- Supply (M10) OR Return (M20) Fan 193592006 1 Contactor- Supply (M10) OR Return (M20) Fan 193592005 1 2 Front Mtd. Aux. Contact- 1NO AND 1NC 193543801 1 1 1 1 3 MMP10, 20 MMP- Supply (MMP10) OR Return (MMP20) Fan 193543014 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 193543013 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 193543009 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 193543008 1 3A Spacer 193545801 1 1 1 1 3B Link 193546001 1 1 1 1 3E Phase Barrier 193545501 1 1 1 1 N/S VFD10, 20 VFD- Supply OR Return Fan 1 1 1 1 1 N/S CB10, 20 Circuit Breaker- Supply OR Return Fan 15A 193550201 1 FB10, 20 Fuseblock- Supply OR Return Fan 193428502 1 1 Fuseblock- Supply OR Return Fan 023780232 1 Fuse- Supply OR Return Fan 50A 113085252 3 Fuse- Supply OR Return Fan 45A 113085251 3 Fuse- Supply OR Return Fan 20A 349937135 3 Fuse Cover- Supply OR Return Fan 193428602 1 1 Fuse Cover/Puller- Supply Fan 349938227 2

208V

230V

460V

575V

Section N- Main Control BoxPower Panel: (04/2013 & Later)

Supply and Return Fan Contactors, Circuit Breakers, & Fusing Components, Continued

N/S= Not Shown on Diagram. 1 Refer to the Inverter Section for VFD p/ns. Reference Code 15 for Inverter brand supplied.2 1 pc. PER Fuse.

Page 201: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 201

Section N- Main Control BoxPower Panel: (04/2013 & Later)

Supply and Return Fan Contactors, Circuit Breakers, & Fusing Components, Continued

15 HP Motor- Code 22 OR 32= M*Y Voltage Ref. Sch. Part Part No. Sym. Description Number 1 M10, 20 Contactor- Supply (M10) OR Return (M20) Fan 193591602 1 1 Contactor- Supply (M10) OR Return (M20) Fan 193537304 1 Contactor- Supply (M10) OR Return (M20) Fan 193598101 1 2 Front Mtd. Aux. Contact- 1NO AND 1NC 193546201 1 1 1 Front Mtd. Aux. Contact- 1NO AND 1NC 193543801 1 3 MMP10, 20 MMP- Supply (MMP10) OR Return (MMP20) Fan 193543306 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 193543305 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 193543010 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 193543301 1 3A Spacer 193545801 1 3B Link 193547401 1 1 1 Link 193546001 1 3E Phase Barrier 193545501 1 N/S VFD10, 20 VFD- Supply OR Return Fan 1 1 1 1 1 N/S CB10, 20 Circuit Breaker- Supply OR Return Fan 20A 193550202 1 FB10, 20 Fuseblock- Supply OR Return Fan 349964253 1 Fuseblock- Supply OR Return Fan 193428502 1 Fuseblock- Supply OR Return Fan 023780232 1 Fuse- Supply OR Return Fan 70A 113085254 3 Fuse- Supply OR Return Fan 60A 113085253 3 Fuse- Supply OR Return Fan 30A 349937137 3 Fuse Cover- Supply OR Return Fan 349964263 1 Fuse Cover- Supply OR Return Fan 193428602 1 Fuse Cover/Puller- Supply Fan 349938227 2

208V

230V

460V

575V

N/S= Not Shown on Diagram. 1 Refer to the Inverter Section for VFD p/ns. Reference Code 15 for Inverter brand supplied.2 1 pc. PER Fuse.

Page 202: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 202

25 HP Motor- Code 32= P*Y 3

20 HP Motor- Code 22 OR 32= N*Y

Section N- Main Control BoxPower Panel: (04/2013 & Later)

Supply and Return Fan Contactors, Circuit Breakers, & Fusing Components, Continued

Voltage Ref. Sch. Part Part No. Sym. Description Number 1 M10, 20 Contactor- Supply (M10) OR Return (M20) Fan 193591701 1 1 Contactor- Supply (M10) OR Return (M20) Fan 193537305 1 Contactor- Supply (M10) OR Return (M20) Fan 193598101 1 2 Front Mtd. Aux. Contact- 1NO AND 1NC 193546201 1 1 1 Front Mtd. Aux. Contact- 1NO AND 1NC 193543801 1 3 MMP10, 20 MMP- Supply (MMP10) OR Return (MMP20) Fan 193543403 1 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 193543013 1 MMP- Supply (MMP10) OR Return (MMP20) Fan 193543303 1 3A Spacer 193545801 1 3B Link 193547501 1 1 Link 193546001 1 Link 193547401 1 3E Phase Barrier 193547301 1 1 Phase Barrier 193545501 1 N/S VFD10, 20 VFD- Supply OR Return Fan 1 1 1 1 1 N/S CB10, 20 Circuit Breaker- Supply OR Return Fan 70A 193550207 1 Circuit Breaker- Supply OR Return Fan 60A 193550206 1 Circuit Breaker- Supply OR Return Fan 30A 193550203 1 FB10, 20 Fuseblock- Supply OR Return Fan 193428502 1 Fuse- Supply OR Return Fan 40A 113085250 3 Fuse Cover- Supply OR Return Fan 193428602 1

208V

230V

460V

575V

N/S= Not Shown on Diagram. 1 Refer to the Inverter Section for VFD p/ns. Reference Code 15 for Inverter brand supplied.

Voltage Ref. Sch. Part Part No. Sym. Description Number 1 M10, 20 Contactor- Supply Fan 80A 193591702 1 1 Contactor- Supply Fan 40A 193591601 1 Contactor- Supply Fan 32A 193598102 1 2 Front Mtd. Aux. Contact- 1NO AND 1NC 193546201 1 1 1 1 3 MMP10, 20 MMP- Supply Fan 57- 75A 193543404 1 MMP- Supply Fan 45- 63A 193543403 1 MMP- Supply Fan 22- 32A 193543304 1 1 3B Link 193547501 1 1 Link 193546001 Link 193547401 1 1 3E Phase Barrier 193547301 1 1 N/S VFD10, 20 VFD- Supply Fan 2 2 2 2 2 N/S CB10, 20 Circuit Breaker- Supply Fan 90A 193550209 1 Circuit Breaker- Supply Fan 80A 193550208 1 Circuit Breaker- Supply Fan 40A 193550204 1 FB10, 20 Fuseblock- Supply Fan 193428502 1 Fuse- Supply Fan 50A 113085252 3 Fuse Cover- Supply Fan 193428602 1

208V

230V

460V

575V

N/S= Not Shown on Diagram. 2 Refer to the Inverter Section for VFD p/ns. Reference Code 15 for Inverter brand supplied.3 A 25HP Supply Fan Motor is only available when Code 31= 24**. A 25HP Motor is not available for Return Fan applications.

Page 203: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 203

Section N- Main Control BoxPower Panel: (04/2013 & Later)

Compressor MMP1, 2, 4 and Contactor M1, 2, 4Diagrams

MMP

3

Contactor

1

Front Mtd.Aux. Contact

2

MMP

2

Contactor1

3

MMP3

Contactor1Spacer3A

3EPhase Barrier

Front Mtd.Aux. Contact

Link 3B

2Front Mtd.

Aux. Contact Link3B

Compressor Link Detail020, 021 Cir #2- 575V

Compressor Link Detail015, 016 Cir #1, 2- 208/460/575V

020, 021 Cir #2- 208/230/460V025, 026 Cir #1- 460V

025, 026 Cir #2- All Voltages030, 031 Cir #2- 208/460/575V

040, 042 Cir #1, 2- 460V

Compressor Link Detail015, 016 Cir #1, 2- 230V

020, 021 Cir #1- 208/230/575V025, 026 Cir #1- 575V

030, 031 Cir #1- 460/575V030, 031 Cir #2- 230V

040, 042 Cir #1, 2- 208/230/575V

4Side Mtd.Aux. Contact

4

4Side Mtd.

Aux. Contact

4 Front Mtd. Aux. Contact

Link 3B

Front Mtd. Aux. Contact

NOTE: The diagrams show ALL possible parts. Not every part shown applies to every unit size/voltage combination.

MMP

3

Front Mtd.Aux. Contact 2

Contactor

1

Link 3B

3EPhase Barrier

Compressor Link Detail025, 026 Cir #1- 208/230V030, 031 Cir #1- 208/230V

4Side Mtd.Aux. Contact

4 Front Mtd. Aux. Contact

Busbar

Compressor Link DetailALL Sizes

Feeder Terminal193545101

5

6

Feeder Terminal193547201

6

4Side Mtd.Aux. Contact

Page 204: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 204

Section N- Main Control BoxPower Panel: (04/2013 & Later)

Compressor MMP1, MMP2 and Contactor M1, M2Unit Sizes 015, 016

015, 016 Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors 1 M1, 2 Contactor- Circuit #1, 2 193537305 2 Contactor- Circuit #1, 2 193591601 2 Contactor- Circuit #1, 2 193537304 2 Contactor- Circuit #1, 2 193592006 2

Compressor MMP's & Parts 2 Front Mtd. Aux. Contact 1 2 2 2 2

3 MMP1, 2 Motor Protector- Circuit #1, 2 193543014 2 Motor Protector- Circuit #1, 2 193543304 2 Motor Protector- Circuit #1, 2 193543009 2 Motor Protector- Circuit #1, 2 193543008 2

3A Spacer 193545801 2 2 2

3B Link 193546001 2 2 2 Link 193547401 2

3E Phase Barrier 193545501 2 2 2

4 Side Mtd. Aux. 1 2 2 2 2

208V

230V

460V

575V

1 EITHER a Side OR a Front Mounted Auxiliary can be installed. Use the Distributor Tools BOM Search function on the Daikin Parts website or contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified.

Page 205: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 205

Section N- Main Control BoxPower Panel: (04/2013 & Later)

Compressor MMP1, 2, 4 and Contactor M1, 2, 4Unit Sizes 020- 031

Unit Size 020, 021 025, 026 030, 031 Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors 1 M1 Contactor 65A 193591701 1 1 1 1 Contactor 40A 193591601 1 1 1 Contactor 32A 193537305 1 1 Contactor 25A 193598101 1 1 Contactor 16A 193592006 1 M2, 4 Contactor 40A 193591601 2 Contactor 32A 193537305 2 2 2 2 2 Contactor 16A 193592006 2 2 Contactor 12A 193592005 2 2 2 Contactor 9A 193534106 2

Comp. MMP's & Parts 2 Front Mtd. Aux. Contact 1 var. var. var. var. var. var. var. var. var. var. var. var. Side Mtd. Aux. Contact 1 var. var. var. var. var. var. var. var. var. var. var. var.

3 MMP1 Motor Protector 45- 63A 193543403 1 1 1 1 Motor Protector 36- 45A 193543306 1 Motor Protector 28- 40A 193543305 1 Motor Protector 22- 32A 193543304 1 Motor Protector 18- 25A 193543303 1 Motor Protector 17- 22A 193543011 1 Motor Protector 14- 20A 193543302 1 Motor Protector 14- 20A 193543010 1 Motor Protector 11- 16A 193543301 1 Motor Protector 7- 10A 193543007 MMP2, 4 Motor Protector 27- 32A 193543014 2 Motor Protector 23- 28A 193543013 2 Motor Protector 22- 32A 193543304 2 Motor Protector 20- 25A 193543012 2 2 Motor Protector 14- 20A 193543010 2 Motor Protector 9- 12.5A 193543008 2 2 Motor Protector 7- 10A 193543007 2 2 2 Motor Protector 5.5- 8A 193542912 2

208V

230V

460V

575V

208V

230V

460V

575V

208V

230V

460V

575V

1 EITHER a Side OR a Front Mounted Auxiliary can be installed. Use the Distributor Tools BOM Search function on the Daikin Parts website or contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified.

Page 206: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 206

Section N- Main Control BoxPower Panel: (04/2013 & Later)

Compressor MMP1, 2, 4 and Contactor M1, 2, 4Unit Sizes 020- 031, Continued

3A M1 Spacer 193545801 1 1 M2, 4 Spacer 193545801 2 2 2 2 2 2 2 2 2 2

3B M1 Link 193547501 1 1 1 1 Link 193547401 1 1 1 1 1 1 Link 193546001 1 1 M2, 4 Link 193547401 2 Link 193546001 2 2 2 2 2 2 2 2 2 2 Link 193545901 2

3E M1 Phase Barrier 193547301 1 1 1 1 Phase Barrier 193545501 1 1

4 Front Mtd. Aux. Contact 1 1 1 1 1 1 1 1 1 1 1 1 1 Side Mtd. Aux. Contact 1 1 1 1 1 1 1 1 1 1 1 1 1

5 M2, 4 Busbar 193546601 1 Busbar 193544301 1 1 1 1 1 1 1 1 1 1 1 6 M2, 4 Busbar Feeder Terminal 193547201 1 Busbar Feeder Terminal 193545101 1 1 1 1 1 1 1 1 1 1 1

208V

230V

460V

575V

208V

230V

460V

575V

208V

230V

460V

575V

Unit Size 020, 021 025, 026 030, 031 Ref. Sch. Part Part No. Sym. Description Number

1 EITHER a Side OR a Front Mounted Auxiliary can be installed. Use the Distributor Tools BOM Search function on the Daikin Parts website or contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified.

Page 207: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 207

Section N- Main Control BoxPower Panel: (04/2013 & Later)

Compressor MMP1 thru 4 and Contactor M1 thru 4Unit Sizes 035- 042D

Compressor Contactors 1 M1- 4 Contactor 40A 193591601 4 4 4 4 4 4 Contactor 25A 193598101 4 4 4 Contactor 25A 193537304 4 4 4

Comp. MMP's & Parts 2 Front Mtd. Aux. Contact 1 4 4 4 4 4 4 4 4 4 4 4 4 Side Mtd. Aux. Contact 1 4 4 4 4 4 4 4 4 4 4 4 4

3 MMP1- 4 Motor Protector 28- 40A 193543305 4 4 4 4 4 4 Motor Protector 14- 20A 193543010 4 4 4 Motor Protector 11- 16A 193543301 4 4 4 Motor Protector 7- 10A 193543007 3A M1- 4 Spacer 193545801 4 4 4

3B M1- 4 Link 193547401 4 4 4 4 4 4 4 4 4 Link 193546001 4 4 4

4 M1- 4 Side Mtd. Aux.- (RPS) 193542801 4 4 4 4 4 4 4 4 4 Front Mtd. Aux.- (RCS) 193542701 4 4 4 4 4 4 4 4 4

5 Busbar 193546601 2 2 2 2 2 2 2 2 2 Busbar 193544301 2 2 2 6 Busbar Feeder Terminal 193547201 2 2 2 2 2 2 2 2 2 Busbar Feeder Terminal 193545101 2 2 2

208V

230V

460V

575V

208V

230V

460V

575V

208V

230V

460V

575V

Unit Size 035 040 042 Ref. Sch. Part Part No. Sym. Description Number

1 EITHER a Side OR a Front Mounted Auxiliary can be installed. Use the Distributor Tools BOM Search function on the Daikin Parts website or contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified.

Page 208: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 208

MMP & Contactor Detail

7

Section N- Main Control BoxPower Panel: (04/2013 & Later)

Condenser Fan Contactors, MMPs, & FusingMMP

8

Link 7B

ContactorFuse Block

Puller

Fuse

9B

9A 9

Adapter

9C

SpeedTrol Fusing DetailF11 OR F21

8APhase Barrier

Unit Size Ref. Sch. Part Part 015 020 025 030 035 040 042 No. Sym Description Number 016 021 026 031 Contactor & Components 7 M11- 22 Contactor- FanTrol C47= 1, 3 193534105 2 2 2 4 4 4 4 Contactor- SpeedTrol C47= 2, 4 193534105 2 2 2 2 7B Link- Contactor to MMP 193545901 1 1 1 1 1 1 1

8 MMP11- 22 MMP & Components MMP- FanTrol Code 47= 1, 3 208V 4.5- 6.3A 193542911 2 2 2 4 4 4 4 230V 3.5- 5A 193542910 2 2 2 4 4 4 4 460V 2.2- 3.2A 193542908 2 2 2 4 4 4 4 575V 1.8- 2.5A 193542907 2 2 2 4 4 4 4 MMP- SpeedTrol Code 47= 2 2 208V 4.5- 6.3A 193542911 2 2 2 2 460V 2.2- 3.2A 193542908 2 2 2 2 575V 1.8- 2.5A 193542907 2 2 2 2 MMP- SpeedTrol Code 47= 4 2 208V 3.5- 5A 193542910 2 2 2 2 460V 1.4- 2.0A 193542906 2 2 2 2 8A Phase Barrier 193545501 2 2 2 2 575V 1.1- 1.6A 193542905 2 2 2 2 5 Bus Bar, 2 pos. 193544301 1 1 1 1 1 1 1

6 Bus Bar, Top Feed 193545101 1 1 1 1 1 1 1

Units w/o Modulating Hot Gas Reheat Code 54= YY SpeedTrol Fusing Code 47= 2 2

9 FB11, 21 Fuse Block 023780232 2 2 2 2 2 2 2 9A F11, 21 Fuse 208V 15A 046742222 6 6 6 6 6 6 6 460V 10A 049759820 6 6 6 6 6 6 6 575V 3A 049759809 6 6 6 6 6 6 6 9B Fuse Cover/Puller 349938227 6 6 6 6 6 6 6 9C DIN Rail Adapter 349938412 4 4 4 4 4 4 4

Busbar

Feeder Terminal

5

6

1 Qty. varies. Confirm the number required BEFORE ordering.2 When Code 47= 6, use the Distributor Tools BOM Search function on the Daikin Parts website or contact Daikin Applied with model and

serial number information to ensure that the correct part(s) are identified.

Page 209: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 209

Section N- Main Control BoxPower Panel: (04/2013 & Later)

Condenser Fan Contactors, MMPs, & Fusing, Continued

Unit Size Ref. Sch. Part Part 015 020 025 030 035 040 042 No. Sym Description Number 016 021 026 031 SpeedTrol Fusing Code 47= 4 9 FB11, 21 Fuse Block 023780232 2 2 2 2 2 2 2 9A F11, 21 Fuse 208V 12A 300042152 6 6 6 6 6 6 6 460V 10A 046742220 6 6 6 6 6 6 6 575V 2A 049759807 6 6 6 6 6 6 6 9B Fuse Cover/Puller 349938227 6 6 6 6 6 6 6 9C DIN Rail Adapter 349938412 4 4 4 4 4 4 4

Units w/ Modulating Hot Gas Reheat Code 54= BM MHGR Fusing Code 47= 1 9 FB11, 21 Fuse Block 023780232 2 2 2 1 1 1 1 9A F11, 21 Fuse 208V 15A 349937127 6 6 6 3 3 3 3 460V, 3.5A 6/13 & Earlier 049759820 6 6 6 3 3 3 3 460V, 10A 7/13 & Later 046742220 6 6 6 3 3 3 3 575V 3A 049759809 6 6 6 3 3 3 3 9B Fuse Cover/Puller 349938227 6 6 6 3 3 3 3 9C DIN Rail Adapter 349938412 4 4 4 2 2 2 2 MHGR Fusing Code 47= 2 9 FB11, 21 Fuse Block 023780232 2 2 2 2 2 2 2 9A F11, 21 Fuse 208V 15A 046742222 6 6 6 6 6 6 6 460V, 3.5A 6/13 & Earlier 049759820 6 6 6 6 6 6 6 460V, 10A 7/13 & Later 046742220 6 6 6 6 6 6 6 575V, 3A 049759809 6 6 6 6 6 6 6 9B Fuse Cover/Puller 349938227 6 6 6 6 6 6 6 9C DIN Rail Adapter 349938412 4 4 4 4 4 4 4

Page 210: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 210

Heat Recovery Control Type 1

100% OA Low Flow 100% OA HI Flow Economizer Code 20= 1E Code 20= 2E Code 20= 3E

Ref. Sch. Part Part No. Sym. Description Number Heat Wheel Contactor 7 M60 Contactor 7A 193534105 1 1 1 1 1 1 1 1 1 1 1 1 M61 Contactor 7A 193534105 1 1 1 1 7B Link- MMP 193545901 1 1 1 1 2 2 2 2 1 1 1 1

Heat Wheel MMP 8 MMP60 Motor Protector 193542909 1 1 1 Motor Protector 193542908 1 1 1 Motor Protector 193542905 1 1 1 Motor Protector 193542904 1 1 1 MMP61 Motor Protector 193542909 1 Motor Protector 193542908 1 Motor Protector 193542905 1 Motor Protector 193542904 1 8E Phase Barrier 193545501 1 1 1 1 1 1 1 1 N/S Busbar 193544301 1 1 1 1 N/S Busbar Feeder Terminal 193545101 1 1 1 1

ERW Fusing 2

9 FB60 ,61 Fuse Block 023780232 1 1 1 2 2 2 1 1 1 9A F60, 61 Fuse 10A 049759816 3 Fuse 9A 349937130 3 Fuse 5A 049759811 3 3 Fuse 4A 349937123 3 3 3 Fuse 3A 349937116 3 3 9B Fuse Cover/Puller 349938227 3 3 3 6 6 6 3 3 3 N/S CB60, 61 Circuit Breaker 15A 193550201 1 2 1 N/S OL61 Overload 0.7- 1A 193547901 1

208V

230V

460V

575V

208V

230V

460V

575V

208V

230V

460V

575V

Section N- Main Control BoxPower Panel: (04/2013 & Later)

Energy Recovery Wheel Contactors, MMPs, & Fusing

7

MMP

8

Link 7B

Contactor

N/S= Not shown on diagram.1 For Heat Wheel Inverter (VFD60) p/ns, refer to the "VFD60 Frost Protection Inverter (Code 24= F)" page in Section A2. 2 Fuse components for the Heat Wheel are located in the Power Panel.

8EPhase Barrier

MMP & Contactor Detail ERW Fusing Detail

Fuse Block

Fuse9A

9

Cover

9B

Page 211: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 211

Section N- Main Control BoxIntelligent Equipment: Code 23= ****A, ****L (Mid 2012 & Later)

Intelligent Equipment® from Daikin Applied (Code 23= ****A) is a secure, cloud-based solution that enables delivery of information to end users and/or service technicians via the web or mobile device. Intelligent Equipment measures the power and performance of every unit providing real-time data streams for benchmarking performance and monitoring system operation.

A power measurement module and communications gateway installed on Daikin Applied equipment enables the unit to be directly connected to the internet via a wireless connection (Wi-Fi, cellular) or through a local area network (LAN) providing management, monitoring, control, analysis, and decision-making functionality

IE Express™ (Code 23= ****L) connects directly to your Daikin unit and offers a low cost, easy to install, entry-level solution to cloud equipment controls for those who don’t need the Energy Management Module (EMM) found in the Intelligent Equipment offering.

Note that this feature may be added to the unit in the field after the initial purchase. In this case, the coding shown above does NOT apply.

Click on this link to access the RPL for Intelligent Equipment: 7000506.

Page 212: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 212

Section O- Refrigeration TubingNotes

Main Codes that pertain: 45, 46, 48, 54

Code 45, Compressor mounting, pertains to the Suction and Discharge Tubing located in the Condenser Section. The suction and discharge lines only pertain to RPS and RCS units. RFS units do not have an integrated Condenser Section and are designed to hook up to a separate condensing unit.

Code 46, Hot Gas Bypass, pertains to the Liquid Line tubing on RPS and RFS units. The drawing below shows the Hot Gas Bypass option installed (Code 46= 1, 2, 4). RCS units come from the factory with NO Liquid Line components installed (Solenoid Valve, Filter Drier, Sight Glass). HGBP can be field installed, however it is important to note that any additional components required for field installed HGBP is ALWAYS field supplied.

Code 48 OR Code 54 (Mid 2012 & Later) determines if the unit is equipped with Modulating Hot Gas Reheat (MHGR) and/or IBC Seismic Construction. The Hot Gas Reheat option adds a Microchannel coil, Step Valve, Control Board, Sensor and additional piping. Note that the Hot Gas Reheat option is not shown in the Refrigeration Tubing diagram below.

Discharge Line

Hot Gas Bypass

Solenoid

Hot Gas Bypass Piping

Suct

ion

Line

Evaporator Coil

Distributor

Expansion Valve

ManualShutoffvalve

FilterDrier

CondenserCoil

Liquid Line Solenoid Valve

Manual Shut Off

Valve

Compressor

Sight Glass

Section O- Refrigeration TubingDiagrams

Page 213: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 213

Section O- Refrigeration TubingDiagrams, Continued 1, 2

Circuit # 1 Shown with Optional Shutoff/Service Valve

(Code 56= *V)

Circuits #1 & # 2 Shown with Optional Hot Gas Bypass on BOTH Circuits

(Code 4= 2, 5)

A370

W270W170

A470

L142

L140

D140

S140

W500

1 Note that some of the base Bubble numbers are used multiple times. Confirm WHICH part(s) are required BEFORE ordering.2 Not every instance of a component is shown on the drawings shown above. Each unit has two (2) circuits. The components listed are

the same for EITHER circuit.

or

and

L147

L146L145

Page 214: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 214

Section O- Refrigeration Tubing Valves, Filter Driers, Sight Glasses, & HGBP & Liquid Line Kits, Continued

Ref. Part Part Unit Size No. Description Number 015 016 5 020 021 025 026 Liquid Line A370, 470 Expansion Valve All Coils 403589604 1 1 5

All Coils 403589607 1 All Coils 910107843 1 All Coils 403589605 1 All Coils 403589606 1

W170, 270 Valve- Solenoid 047931316 2 2 5 2 2 Valve- Solenoid 047931315 2 2

L140, 240 Sight Glass 015997804 2 2 5 2 2 Sight Glass 015997805 2 2

Filter Drier L145, 245 Sealed Core 098871601 2 2 5 2 2 Sealed Core 098803001 2 2 L146, 246 Replaceable Core- Shell 2 098860601 2 2 5 2 2 Replaceable Core- Shell 2 001360700 2 2 L147, 247 Replaceable Core- Core 2 001360800 4 4 5 4 4 4 4

L142, 242 Valve- Shutoff 910120909 6 2 2 5 2 2 2 2

N/S Check Valve, MHGR (Code 48= H, K) OR (Code 54= BM) 112053309 7 1 1 5 1 1 (Code 48= H, K) OR (Code 54= BM) 112053305 7 1 1

Suction Line S140, 240 Shut- Off Valve 500550101 2 2 5

Shut- Off Valve 113114501 2 2 Shut- Off Valve 113114601 2 2

Discharge Line D140, 240 Shut- Off Valve 500550001 2 2 5 2 2 2 2

N/S Liquid Line Kit (RCS to RFS) 193330712 4 N/A 4 4 4 4

N/S Liquid Line Kit (RCS Standalone) 193330711 4 N/A 4 N/A 4 N/A

N/S Hot Gas Bypass Kit 193330721 1 1, 5 1 1 1 1

W500 Valve only, Hot Gas Bypass 258951301 1 3 1 3 , 5 1 3 1 3 1 3 1 3

N/S= Not shown on diagram.1 Each Hot Gas Bypass Kit covers ONE circuit. To add Hot Gas Bypass to BOTH circuits order TWO kits. The Hot gas Bypass Kit

includes a Solenoid Valve and Instructions. ANY AND ALL additional piping and wiring required is field supplied.2 Code 46= 3, 4, 5.3 Code 46= 1, 2, 4, 5. If Code 46= 1, 4 then there is Hot Gas Bypass on Circuit #1 only. 4 Each Liquid Line Kit covers ONE circuit. To add Liquid Line components to BOTH circuits order TWO kits. The RCS Standalone Kit

includes a Solenoid Valve, Replaceable Core Filter Drier, Sight Glass, and Instructions. The RCS to RFS Kit contains all the previously mentioned parts except for the Solenoid Valve. In either case, ALL piping and additional wiring required is field supplied.

5 Starting 04/15 ALL 016D units have been converted to use Inverter Compressors ONLY. For Inverter Compressor units (Code 44= V, W) refer to form 7000512.

6 This is a recommended replacement valve. If replacing an original valve, minor field modifications may be required.7 There is another Check Valve related to the MHGR circuit located on the Hot Gas Reheat piping. Refer to one page after the next for

part numbers.

Page 215: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 215

Ref. Part Part Unit Size No. Description Number 030 031 5 035 040 042 Liquid Line Components A370 Expansion Valve- Circuit #1 All Coils 403589401 1 1 5 1 1 1 A470 Expansion Valve- Circuit #2 All Coils 403589606 1 1 5

All Coils 403589401 1 1 1

W170, 270 Valve- Solenoid 047931315 2 2 5 Valve- Solenoid 047931313 2 2 2

S140, 240 Valve- Shutoff 910120909 6

Sight Glass 015997805 2 2 5 2 2 2

Filter Drier L145, 245 Sealed Core 098803001 2 2 5 2 2 2 L146, 246 Replaceable Core- Shell 2 001360700 2 2 5 2 2 2 L147, 247 Replaceable Core- Core 2 001360800 4 4 5 4 4 4

N/S Check Valve (Code 48= H, K) OR (Code 54= BM) 112053305 7 1 1 5 1 1 1

Suction Line S140, 240 Shut- Off Valve 113114601 2 2 5 2 2 2

Discharge Line D140, 240 Shut- Off Valve 500550001 2 2 5 Shut- Off Valve 113114501 2 2 2

N/S Liquid Line Kit (RCS to RFS) 193330712 4 N/A 4 4 N/A

N/S Liquid Line Kit (RCS Standalone) 193330711 4 N/A 4 4 N/A

Hot Gas Bypass N/S Hot Gas Bypass Kit 193330721 1 1, 5 1 1 1

W500 Valve only, Hot Gas Bypass 258951301 3 3, 5 3 3 3

N/S= Not shown on diagram.1 Each Hot Gas Bypass Kit covers ONE circuit. To add Hot Gas Bypass to BOTH circuits order TWO kits. The Hot Gas Bypass Kit

includes a Solenoid Valve and Instructions. Due to the many possible variations in unit location configurations ANY AND ALL additional piping and wiring required is field supplied.

2 Code 46= 3, 4, 5.3 Code 46= 1, 2, 4, 5. If Code 46= 1, 4 then there is Hot Gas Bypass on Circuit #1 only. 4 Each Liquid Line Kit covers ONE circuit. To add Liquid Line components to BOTH circuits order TWO kits. The RCS Standalone Kit

includes a Solenoid Valve, Replaceable Core Filter Drier, Sight Glass, and Instructions. The RCS to RFS Kit contains all the previously mentioned parts except for the Solenoid Valve. In either case, Any and ALL piping and additional wiring required is field supplied.

5 Starting 04/15 ALL 031D units have been converted to use Inverter Compressors ONLY. For Inverter Compressor units (Code 44= V, W) refer to form 7000512.

6 This is a recommended replacement valve. If replacing an original valve, minor field modifications may be required.7 There is another Check Valve related to the MHGR circuit located on the Hot Gas Reheat piping. Refer to the following page for part

numbers.

Section O- Refrigeration Tubing Valves, Filter Driers, Sight Glasses, & HGBP & Liquid Line Kits, Continued

Page 216: RPL: RPS/RFS/RCS, 015-042, Vintage D, Roofpak Single Zone ...Standard & Digital Scroll Compressor Models RPS, RFS, RCS 015 - 042 Vintage D Code 44= R, D To find your Daikin Applied

Rooftop Std. Cmpr. Units: RPS/RFS/RCS 015-042 "D" Rev. AQ 08/19 RPL 7000150 / Page 216

Ref. Part Part Unit Size No. Description Number 015 016 020 021 025 026 030 031 035 040 042 200 Microchannel Coil 403822701 1 1 1 1 1 1 1 1 1 1 1 Microchannel Coil, E-Coated 403822702 1 1 1 1 1 1 1 1 1 1 1 N/S Electronic Step Valve 113167702 1 1 1 1 1 1 1 1 N/S Electronic Step Valve 113167704 1 1 1 N/S Valve- Motor Kit 113167709 1 1 1 1 1 1 1 1 1 1 1 N/S Valve- Washer (order with Motor kit) 300045244 1 1 1 1 1 1 1 1 1 1 1 N/S Sensor 113167904 1 1 1 1 1 1 1 1 1 1 1 212 Support channel- (Connection side) 403789801 1 1 1 1 1 1 1 1 1 1 1 213 Support channel- (Return side) 403789701 1 1 1 1 1 1 1 1 1 1 1 233 Check Valve, MHGR Piping .875" 112053305 2 1 1 1 1 1 1 1 1 1 1 1 234 Valve- Bleed Down 404031001 1 1 1 1 1 1 1 1 1 1 1 235 Coil- Bleed Down Valve 404031101 1 1 1 1 1 1 1 1 1 1 1

Section O- Refrigeration TubingModulating Hot Gas Reheat (MHGR) 1

(Code 48= H, K) OR (Code 54= BM)

200

213

212

N/S= Not Shown on Diagram.1 Hot Gas Reheat is located on Circuit #2 only.2 There is another Check Valve related to the MHGR circuit located on the Liquid Line piping. Refer to the two previous pages for part

numbers.

MHGR Piping Detail(015- 030 shown)

233

235234

AirFlo

w