We are the turn key landscape contractor and wants to bridge the market gapbetween what customers today have in the Indian construction industry and whatthey can have with the already available technologies, products and services inother advanced countries.
Electronic Testing of WaterproofingMembranes
Vertical Gardens / Living Walls Rooftop/ Podium Natural Gardens
- EFVM technology by ILD- First time in India- Quality assurance- Used worldwide- Non-destructive testing- Secures future
- Unique Design- Pattern Flexibility- Reliable & Automated Irrigation- Plug & Play mechanism- With waterproofing foam boards- Aesthetic, simple and solves the
purpose
- Turnkey Solution- FLL certified OptiGreen products- EFVM assurance- New hardscaping product
builtup- Need of the hour
+ve
WaterSprinkler
Water ProofingLayer
-ve
StructureDeck
Vector 9Wires
Low voltage , Non-destructive integrity testing of waterproofing membranes
What is Electric Field Vector Mapping (EFVM®) ?
Step 3: Injecting low voltage positive charge in the substrate & negative charge in Vector 9 wireloop. Creating the “Field Plate”
Disadvantages of flood testing:
Difficulty in finding the exact location of the defect
Difficult / impossible with sloped/ vertical decks.
Delay in project schedule if retests are required
Not possible after an overburden is installed
Requires a significant water source and supply
Structural concerns due to additional weight load
Weather restraints (rain or freezing temperatures)
Strain on drainage systems upon completion of the
test.
DURING MEMBRANE INSTALLATION- Mechanical damage caused by others- Workmanship defect- Material defect- Design Defect
AFTER MEMBRANE INSTALLATION- Mechanical damage caused by others- Weather related defects- Membrane deterioration
* Leakage monitoring system can be placed inside the landscapingfor detecting any leakage in future.
Structural Deck
Vector 9 WiresProtection Fleece
Waterproofing Layer
Filter Fabric
Growing Medium
Solid Drainage Board
Vegetation
-ve
+ve
Leakage
* Leakage monitoring system can be placed inside thelandscaping for detecting any leakage in future.
We detect the source of leakage. Grouting the leakage pointis just the temporary solution.
EFVM takes the guesswork out of waterinfiltration
Shape of the structure does not matter
No schedule delays
Non-destructive testing
Adding “GREEN” quotient to projects
EVFM® can be performed during inclementweather.
Leak Detection System that stays in place
Membrane performance can be monitoredduring it’s lifespan through the overburden.
Eliminates unnecessary removal of theoverburden to locate a membrane breach
You give us the space, leave the rest to us. We bring landscape to your doorstep .. piece by piece !!
It can’t get simpler than this !!Keep Calm & Go Green !!
Project : C.S. International AirportLocation : MumbaiClient : Larsen & Toubro
Project : Birla Aurora, WorliLocation : MumbaiClient : Aditya Birla Group
Project : DTA RefineriesLocation : JamnagarClient : Reliance
Project : First International Finance CenterLocation : MumbaiClient : Citibank
Project : High Commission of CanadaLocation : DelhiClient : Government of Canada
Project : IIM UniversityLocation : AhmedabadClient : IIM
Utkarsh Maloo (MSCE, USA)Rooftech Enterprises (P) Ltd.
Email : [email protected]: 91- 9833048421
www.rooftechent.com