Rooftech Enterprises - Profile

20
Utkarsh Maloo (MSCE, USA) Rooftech Enterprises (P) Ltd. Email : [email protected] Contact: 91- 9833048421 www.rooftechent.com

Transcript of Rooftech Enterprises - Profile

Utkarsh Maloo (MSCE, USA)Rooftech Enterprises (P) Ltd.

Email : [email protected]: 91- 9833048421

www.rooftechent.com

We are the turn key landscape contractor and wants to bridge the market gapbetween what customers today have in the Indian construction industry and whatthey can have with the already available technologies, products and services inother advanced countries.

Electronic Testing of WaterproofingMembranes

Vertical Gardens / Living Walls Rooftop/ Podium Natural Gardens

- EFVM technology by ILD- First time in India- Quality assurance- Used worldwide- Non-destructive testing- Secures future

- Unique Design- Pattern Flexibility- Reliable & Automated Irrigation- Plug & Play mechanism- With waterproofing foam boards- Aesthetic, simple and solves the

purpose

- Turnkey Solution- FLL certified OptiGreen products- EFVM assurance- New hardscaping product

builtup- Need of the hour

+ve

WaterSprinkler

Water ProofingLayer

-ve

StructureDeck

Vector 9Wires

Low voltage , Non-destructive integrity testing of waterproofing membranes

What is Electric Field Vector Mapping (EFVM®) ?

Step 2: Vector-9 conductor wire being installed on the waterproofing membrane.

Step 3: Injecting low voltage positive charge in the substrate & negative charge in Vector 9 wireloop. Creating the “Field Plate”

- +A

StructureDeck

WaterproofingLayer

Disadvantages of flood testing:

Difficulty in finding the exact location of the defect

Difficult / impossible with sloped/ vertical decks.

Delay in project schedule if retests are required

Not possible after an overburden is installed

Requires a significant water source and supply

Structural concerns due to additional weight load

Weather restraints (rain or freezing temperatures)

Strain on drainage systems upon completion of the

test.

DURING MEMBRANE INSTALLATION- Mechanical damage caused by others- Workmanship defect- Material defect- Design Defect

AFTER MEMBRANE INSTALLATION- Mechanical damage caused by others- Weather related defects- Membrane deterioration

* Leakage monitoring system can be placed inside the landscapingfor detecting any leakage in future.

Structural Deck

Vector 9 WiresProtection Fleece

Waterproofing Layer

Filter Fabric

Growing Medium

Solid Drainage Board

Vegetation

-ve

+ve

Leakage

* Leakage monitoring system can be placed inside thelandscaping for detecting any leakage in future.

We detect the source of leakage. Grouting the leakage pointis just the temporary solution.

Can be used for vertical walls as long as access is availableon the membrane side to scan.

EFVM takes the guesswork out of waterinfiltration

Shape of the structure does not matter

No schedule delays

Non-destructive testing

Adding “GREEN” quotient to projects

EVFM® can be performed during inclementweather.

Leak Detection System that stays in place

Membrane performance can be monitoredduring it’s lifespan through the overburden.

Eliminates unnecessary removal of theoverburden to locate a membrane breach

Height adjustable and varying load bearingcapacity

Use of pedestals along with ILD wired below

Finding leak points through EFVM andeasy repair.

You give us the space, leave the rest to us. We bring landscape to your doorstep .. piece by piece !!

It can’t get simpler than this !!Keep Calm & Go Green !!

The goal isn’t to live forever, the goal is to create something that will !!

Project : C.S. International AirportLocation : MumbaiClient : Larsen & Toubro

Project : Birla Aurora, WorliLocation : MumbaiClient : Aditya Birla Group

Project : DTA RefineriesLocation : JamnagarClient : Reliance

Project : First International Finance CenterLocation : MumbaiClient : Citibank

Project : High Commission of CanadaLocation : DelhiClient : Government of Canada

Project : IIM UniversityLocation : AhmedabadClient : IIM

Utkarsh Maloo (MSCE, USA)Rooftech Enterprises (P) Ltd.

Email : [email protected]: 91- 9833048421

www.rooftechent.com