Robustness Testingwith Fault Injection
Robustness - the degree to which a system operates correctly in the presence of exceptional inputs or stressful environmental conditions
The goal of robustness testing is to develop test cases and test environments where a system's robustness can be assessed.
![Page 3: Robustness testing](https://reader036.fdocuments.in/reader036/viewer/2022082501/546f298daf79597b298b59f3/html5/thumbnails/3.jpg)
3
IV&V Facility
Process Overview Fault Injection
Preparation Test Execution Log Analysis
Documentation Describes scope of test
campaign Lists directives/routines
tested Describes test results
![Page 4: Robustness testing](https://reader036.fdocuments.in/reader036/viewer/2022082501/546f298daf79597b298b59f3/html5/thumbnails/4.jpg)
4
IV&V Facility
RTOS API Test Results
RTOS Directives found in Project
FSW
Directives found in API Test Results and
Project FSW
Flight Software Traces
Source Navigator
Source Code
![Page 5: Robustness testing](https://reader036.fdocuments.in/reader036/viewer/2022082501/546f298daf79597b298b59f3/html5/thumbnails/5.jpg)
5
IV&V Facility
Test Execution
![Page 6: Robustness testing](https://reader036.fdocuments.in/reader036/viewer/2022082501/546f298daf79597b298b59f3/html5/thumbnails/6.jpg)
6
IV&V Facility
DocumentationSample Fault Table
Declaration int taskSpawn ( char * name, int priority, int options, int stackSize, FUNCPTR entryPt, int arg1, int arg2, int arg3, int arg4, int arg5, int arg6, int arg7, int arg8, int arg9, int arg10 )
Fault Location C:\TornProj\Test2\usrAppInit.cline: 186
Test Case 1 set to a value outside of range 0 to 255
Results Error ID #: 0x3d001Error Description: S_objLib_OBJ_ID_ERRORAnalysis: Since the range of priority levels are limited to be between 0 and 255, anything out of this range is expected to return this error message.
![Page 7: Robustness testing](https://reader036.fdocuments.in/reader036/viewer/2022082501/546f298daf79597b298b59f3/html5/thumbnails/7.jpg)
7
IV&V Facility
Results VxWorks
HIGHLY AUTOMATED using scripts and support programs Testing VxWorks 5.5 Testing POSIX and Classic APIs GLAST Flight Software Traces – Complete nearly 300 functions used VxWorks Libraries
Task Management, Task Hook, Task Information, Task Show, Task Variables Support, Timer, Timex, Clock Tick Support, Watchdog Timer
Over 70 routines Progress
S:\NASA Shared\Research and Development Fisher \FacilityResearchProgram\Robustness Testing\VXWORKS \GLASTProgress.xls
Documents GLAST/VxWorks Robustness Testing
![Page 8: Robustness testing](https://reader036.fdocuments.in/reader036/viewer/2022082501/546f298daf79597b298b59f3/html5/thumbnails/8.jpg)
8
IV&V Facility
Automation Tools Test Case Generator Test Script Generator Various Scripts (Batch Files) Xception Robustness testing lends itself to automation,
saving time and money S:\NASA Shared\Research and Development -
Fisher\FacilityResearchProgram\Robustness Testing\VXWORKS
![Page 9: Robustness testing](https://reader036.fdocuments.in/reader036/viewer/2022082501/546f298daf79597b298b59f3/html5/thumbnails/9.jpg)
9
IV&V Facility
Applicability Any project that utilizes a Real-Time
Operating System with an Application Programmable Interface (API)VxWorksRTEMS
Both developers and analysts may find the tool useful
![Page 10: Robustness testing](https://reader036.fdocuments.in/reader036/viewer/2022082501/546f298daf79597b298b59f3/html5/thumbnails/10.jpg)
10
IV&V Facility
Research Infusion Project This project’s goal is to transition mature
software engineering research-derived technologies into practice by NASA and its contractors.
Our task was to evaluate the tools, create a lessons learned document, and support future users of the tools.
![Page 11: Robustness testing](https://reader036.fdocuments.in/reader036/viewer/2022082501/546f298daf79597b298b59f3/html5/thumbnails/11.jpg)
11
IV&V Facility
Tool Evaluation Criteria Is it a burden to process? Are features organized intuitively? Was good documentation included? Is it useful? What errors were encountered?