Robert JohnsonFaculty: Dr. Calvin HowellGrad Student: David Ticehurst
Development of a Neutron Detector with Kinetic Energy Measurement Capability
![Page 2: Robert Johnson Faculty: Dr. Calvin Howell Grad Student: David Ticehurst Development of a Neutron Detector with Kinetic Energy Measurement Capability.](https://reader036.fdocuments.in/reader036/viewer/2022062313/56649d0e5503460f949e45a8/html5/thumbnails/2.jpg)
MotivationBasic research in nuclear physics
Scattering Reaction Transfer Reaction Charge Exchange
Applications Neutron Detection without using T.O.F method Nuclear Security
![Page 3: Robert Johnson Faculty: Dr. Calvin Howell Grad Student: David Ticehurst Development of a Neutron Detector with Kinetic Energy Measurement Capability.](https://reader036.fdocuments.in/reader036/viewer/2022062313/56649d0e5503460f949e45a8/html5/thumbnails/3.jpg)
Proven TechnologyModeration and then Charge Exchange
Effective as neutron counter Detection Efficiency: 40-45% Timing on the order of μs
Scintillation Effective neutron counter Detection efficiency: 20-25% Timing on the order of ns Energy information using T.O.F techniques
![Page 4: Robert Johnson Faculty: Dr. Calvin Howell Grad Student: David Ticehurst Development of a Neutron Detector with Kinetic Energy Measurement Capability.](https://reader036.fdocuments.in/reader036/viewer/2022062313/56649d0e5503460f949e45a8/html5/thumbnails/4.jpg)
Experimental Set-upTwo PMTs attached to a 10Boron loaded
Analog MPD-4 -> TAC
Digital Digitizer
Sources used 22Na (Calibration/Testing) 137CS (Calibration/Testing) AmBe (Neutron Source)
![Page 5: Robert Johnson Faculty: Dr. Calvin Howell Grad Student: David Ticehurst Development of a Neutron Detector with Kinetic Energy Measurement Capability.](https://reader036.fdocuments.in/reader036/viewer/2022062313/56649d0e5503460f949e45a8/html5/thumbnails/5.jpg)
Data Acquisition(PH)Energy Resolution: 26%
![Page 6: Robert Johnson Faculty: Dr. Calvin Howell Grad Student: David Ticehurst Development of a Neutron Detector with Kinetic Energy Measurement Capability.](https://reader036.fdocuments.in/reader036/viewer/2022062313/56649d0e5503460f949e45a8/html5/thumbnails/6.jpg)
Data Acquisition(PSD)Pulse Shape Discrimination
![Page 7: Robert Johnson Faculty: Dr. Calvin Howell Grad Student: David Ticehurst Development of a Neutron Detector with Kinetic Energy Measurement Capability.](https://reader036.fdocuments.in/reader036/viewer/2022062313/56649d0e5503460f949e45a8/html5/thumbnails/7.jpg)
Data Acquisition(PH vs. PSD)
![Page 8: Robert Johnson Faculty: Dr. Calvin Howell Grad Student: David Ticehurst Development of a Neutron Detector with Kinetic Energy Measurement Capability.](https://reader036.fdocuments.in/reader036/viewer/2022062313/56649d0e5503460f949e45a8/html5/thumbnails/8.jpg)
Second PulseReaction
10B + n -> 6Li + α + ϒ(480 keV)
Shows that all the energy in the initial reaction was released in the scintillator
Can only be detected with the digital set up
![Page 9: Robert Johnson Faculty: Dr. Calvin Howell Grad Student: David Ticehurst Development of a Neutron Detector with Kinetic Energy Measurement Capability.](https://reader036.fdocuments.in/reader036/viewer/2022062313/56649d0e5503460f949e45a8/html5/thumbnails/9.jpg)
Results of Time difference
Time (ns)
![Page 10: Robert Johnson Faculty: Dr. Calvin Howell Grad Student: David Ticehurst Development of a Neutron Detector with Kinetic Energy Measurement Capability.](https://reader036.fdocuments.in/reader036/viewer/2022062313/56649d0e5503460f949e45a8/html5/thumbnails/10.jpg)
Future PlansFinish the code to analyze the PH, PSD of
second pulse
Search for the alpha particles
![Page 11: Robert Johnson Faculty: Dr. Calvin Howell Grad Student: David Ticehurst Development of a Neutron Detector with Kinetic Energy Measurement Capability.](https://reader036.fdocuments.in/reader036/viewer/2022062313/56649d0e5503460f949e45a8/html5/thumbnails/11.jpg)
ReferencesKnoll, Glenn F. Radiation Detection and
Measurement. 4th ed. Hoboken: John Wiley & Sons, 2012. Print.