Investment in Roadway Lighting Solutions. Let there be Lighting.
Roadway Lighting Conference - Anchorage, Alaska · Roadway Lighting Conference Anchorage Alaska,...
Transcript of Roadway Lighting Conference - Anchorage, Alaska · Roadway Lighting Conference Anchorage Alaska,...
12/19/2008
1
Roadway Lighting Conference Anchorage Alaska, Dec 08
LED and Adaptive Lighting PilotsLED and Adaptive Lighting Pilots in British Columbia
Roy Hughes, P.Eng., LC
12/19/2008
2
The Provincial Energy Goals…
BC Provincial Energy Commitments:gy
–50% of BC Hydro’s incremental resource % yneeds met by conservation by 2020
–BC Government carbon neutral by 2010
–BC will be electricity self-sufficient by 2016
12/19/2008
3
The Municipal Challenges…
–Local government’s spend significant amounts of money on excess lighting
–BC municipalities have committed to lowering greenhouse gases
–Power costs are rising faster than inflation.
12/19/2008
4
A Practical Solution
• The most immediate solution and the• The most immediate solution and the cleanest source of energy is "the energy that isn't used"the energy that isn t used
• Municipalities have reduced facilities t i t d b P S tenergy costs assisted by Power Smart
Energy Efficiency programs and Provincial i tiincentives
• What can we do for Roadway Lighting?
12/19/2008
5
Source Efficacies
200
Accelerated R&D for White Light SSL
125
150
175 White Light SSLLaboratory
per w
att)
White Light SSLCommercial
75
100
125Metal Halide Pulse start
T-8 lampT-12 ES
cy (l
umen
s p Commercial
Conventional Lighting Technologies Potential Growth
for Conventional Light Sources
25
50
75
Mono
T-12 fluorescent
MonoLEDE
ffica
c
01970 1980 1990 2000 2010 2020
OLED
YearSSL Laboratory and Commercial Curves, revised May 2006
12/19/2008
6
12/19/2008
7
42 Watt LED replaces 175 Watt MH
12/19/2008
8
42 Watt replaces 150 Watt HPS
12/19/2008
9
Vancouver Children’s Hospital
LED Parking Lot Lighting
12/19/2008
10
MOT/BCH Pilot - Cole Rd Rest Area
12/19/2008
11
135 Watt LED125 Watt LED
replaces 200W HPS
l t k
135 Watt LED
www.leotek.com
http://www.ruud.ca/led/The_EDGE.pdf
12/19/2008
12
Induction Lighting
Advantages:• Long Life - 100,000 hours
100 Watt Induction LampLong Life 100,000 hours
• Low Maintenance• Excellent colour Rendering – 80 CRIExcellent colour Rendering 80 CRI• Good efficacy – 80 lumens/watt• Instant on and instant re-strikeInstant on and instant re strike
12/19/2008
13
Cole Road Rest Area
12/19/2008
14
Cole Road Rest Area
HPS vs LLED ( # 1C 2 and 1D 2 )
High Pressure Sodium & LED- Sample #1
50
60
70
20
30
40 I l luminance ( lux)
0
10
D ist ancf
D ist ance alo ng curb ( f t )
e f ro m curb ( f t )
12/19/2008
15
Cole Road Rest Area
HPS vs R LED ( # 1A 1, 1B 1, and 1A 2 )
High Pressure Sodium & LED
60
– Sample #2
40
50
60
10
20
30 I l luminance ( lux)
0
10
D ist ance
f romD ist ance along curb ( f t )
f rom curb ( f t )
12/19/2008
16
Cole Road Rest Area
135 Watt LED135 Watt LED
250 Watt HPS
12/19/2008
17
Cole Road Rest Area
HPS vs M IL ( # 1A 6 and 1D 4 )
High Pressure Sodium & Induction Lamp
80
40
50
60
70
I l luminance
10
20
30
40 ( lux)
0
D ist ance alo ng curb ( f t )
D ist ance f rom curb
D ist ance alo ng curb ( f t ) ( f t )
12/19/2008
18
100 W tt I d ti100 Watt Induction
250 Watt HPS250 Watt HPS
12/19/2008
19
Cole Road Rest Area
12/19/2008
20
Adaptive Roadway LightingMaple Street, Vancouver, BC
100 Watt LED
401 Highway Toronto Ontario
1000 Watt HPS1000 Watt HPS
12/19/2008
21
Adaptive Lighting – Street Lighting Opportunities
Opportunity Advantage
1 Reduce Lumen Output of Lamps to • Energy Savings 1 p p
Maintained Levelsgy g
• Obtrusive Light Reduction
S f S2 Dim Over-Lighted Neighborhoods
• Potential Significant Energy Savings• Obtrusive Light Reduction
3 Match Lumen Output to Variable IESNA Pedestrian Conflict Levels
• Significant Energy Savings• Obtrusive Light Reduction
12/19/2008
22
Opportunity - Dim to maintain design level
Light reduced to Maintained Levels for life of lamp - up to 26% savings
12/19/2008
23
Opportunity – Reduce Lighting in Over-Lighted Areas
Set spacing results in over-lighted roadway
12/19/2008
24
Opportunity - Match Lumen Outputto Variable IESNA Pedestrian Conflict Levels
Potential Savings – 30% to 50%
12/19/2008
25
IESNA Roadway ClassificationsHigh – Medium - Low
• The IESNA classifies by pedestrian activity:
• High – 100 or more pedestrians per hour – within a city block (200m)
• Medium – 11 to 99 pedestrians
• Low – 10 or fewer pedestrians
Photo courtesy of Night Saver
12/19/2008
26
Adapt Lighting to the Requirements
• Unless there is “High”activity throughout the nightactivity throughout the night,
• the lower levels allow for safety and safe movement yof vehicles and pedestrians.
• The potential energy savings up to 50%
Photo courtesy of Night Saver
12/19/2008
27
Control Types
Adaptive Lighting Controls & Equipment
• Static – Preset schedule or time– Not adjustable
• Dynamic y– Programmable– Adjustable
T i ti– Two-way communication
12/19/2008
28
Adapt Lighting Controls - static
Photo courtesy of Night Saver
12/19/2008
29
Adaptive Lighting Controls - static
Set it and forget it
-factory pre-set
-operatesoperates independently
not adjustable-not adjustable
Night-Saver
12/19/2008
30
Adaptive Lighting – dynamic
Photo courtesy of STI
12/19/2008
31
Adaptive Lighting - dynamic
• Microprocessor controlled
• Wireless communicationscommunications
• Intelligently controls the output of the lamp to meet design specs for entire lifespanp
• Easy to install on existing or new lamp fi tfixtures
12/19/2008
32
Prince George Pilot Project
15th Ave Prince George, BC
Project Plan:To retrofit 171 Luminaires with Adaptive Lighting Control
2.5 km main arterial with commercial and residential roadway. Transit line operational until 8 p m with varying pedestrian conflict levelsTransit line operational until 8 p.m. with varying pedestrian conflict levels.
12/19/2008
33
Energy Savings Prince George Pilot
67 Luminaires were converted16 luminaires were dusk to dawn controlled only
4 luminaires were dimmed to 50% - 11pm to 6am47 luminaires were dimmed to 70% 11pm to 6 am47 luminaires were dimmed to 70% - 11pm to 6 am
Power consumption at 100% light = 312 WP ti t 70% li ht 232 WPower consumption at 70% light = 232 WPower consumption at 50% light = 187 W
Annual Savings this Project: 36,000 kWh
Percent Savings: 26 5%Percent Savings: 26.5%
August 2005 to Sept 2006
12/19/2008
34
Conclusions
Performance assumptions were verified through laboratory p g yand field testing
Significant benefits and potential for owners and society:Dimming will Save Money and Reduce FutureInfrastructure NeedsObtrusive Light will be ReducedSystem Streamlines Asset ManagementEnergy Consumption can be Tracked for Un-metered Installations
12/19/2008
35
The BC Picture
Why BC Hydro is consideringWhy BC Hydro is considering Adaptive Roadway Lighting
There are 300,000 street lights in BC. Estimated power consumed in a year would be
i t l 360 illi kWhapproximately 360 million kWh. Just imagine 20% reduction in off peak hours.
That’s 72 million kWh hours per year
12/19/2008
36
Initial review of opportunityApproval to proceed to next stepApproval to proceed to next step
Detailed study of energy savings potentialSt d 100% id f b BC H d if i d i O t b
Hydro incentives cover up to 60% of the installed costs of
Study 100% paid for by BC Hydro if signed on in October
y pthe technology.
12/19/2008
37
Energy Efficient Roadway Lighting inRoadway Lighting in
British Columbia !
Roy Hughes, PEng, LC604-453-6473
roy hughes@bchydro [email protected]/business
12/19/2008
38
Questions
• Contact information:
• Roy Hughes, PEng, LCBC Hydro Engineeringy g gBC Hydro Power Smart604-453-6472
• www.bchydro.com