RMG_324_20_GB_2011_02
-
Upload
neue-formen-gmbh-co-kg -
Category
Documents
-
view
235 -
download
10
description
Transcript of RMG_324_20_GB_2011_02
Zero-pressure gas regulator RMG 324 324.20
Serving the Gas Industry
Worldwide
OPERATING AND MAINTENANCE INSTRUCTIONS/SPARE PARTS Version 03/2011
Contents Page
1. General information 3
1.1 Safety information 3
2. Specific maintenance instructions 4
2.1 Valve rod 4
2.2 Valve disc 4
2.3 Diaphragm 4
2.4 Tightening torques 4
2.5 Lubricants 4
3. Specific operating instructions 5
3.1 Fitting position 5
3.2 Vent line connection 5
3.3 Dirt traps (gas filters) 5
3.4 Setting the setpoint 5
3.5 Switching from internal to external measuring impulse connection (retrofit) 5
3.6 Switching from external to internal measuring impulse connection (retrofit) 5
4. Spare parts
4.1.1 Spare parts drawing for main valve DN 65, DN 80, DN 100 6
4.1.2 Spare parts list for main valve DN 65, DN 80, DN 100 7
4.2.1 Spare parts drawing for main valve DN 80 – type: part no. 10031423 8
4.2.2 Spare parts list for main valve DN 80 – type: part no. 10031423 9
4.3.1 Spare parts drawing of regulating assembly RE 2 for DN 65, DN 80, DN 100 10
4.3.2 Spare parts list of regulating assembly RE 2 for DN 65, DN 80, DN 100 11
4.4.1 Spare parts drawing of regulating assembly for DN 80 – type: part no. 10031423 12
4.4.2 Spare parts list of regulating assembly for DN 80 – type: part no. 10031423 13
5. Parts for maintenance purposes 14
324.20 p.02
324.20 p.3
Danger of damage to property and /or the environment
Important additional information
Eye catcher used for:
Danger to life and limb
Note
Caution!!
Danger!!
1. General information
All persons involved with the assembly, operation and / or maintenance of gas pressure regulators must read and
understand all of the following documents:
– Technical product information (brochure RMG 324.00) – this RMG document contains the technical data and
dimensions of the equipment and a description of its design and mode of operation.
– General operating manual for gas pressure regulators and safety devices – this RMG document contains
information on assembly and operation as well as general information on troubleshooting.
– Operating and maintenance instructions / spare parts (brochure RMG 324.20) – this RMG document contains
more detailed information on assembly and operation of the gas pressure regulator.
There are national laws and regulations for all sorts of jobs on gas equipment, from planning to maintenance. Be sure
to comply. (In Germany, for instance, DVGW work sheets G 600, G 459/II, G 491 and G 495.)
Inspection and maintenance intervals depend mostly on operating conditions and the nature and properties of the gas.
There are no general rules or recommendations for intervals. For Germany, we recommend to consider maintenance
intervals as stated in DVGW work sheet G 495 in a first instance. However, in the mid-term, intervals must be
adapted to the requirements of each specific equipment.
During maintenance, components must be cleaned and then checked thoroughly. This is necessary even if there
have not been any unusual observations during operation and / or functional testing. Checks must focus, in particular,
on diaphragms and seals and all movable parts and their respective bearings. Any and all defective parts must be
replaced with new ones. The same applies to O rings removed during disassembly.
Do not use any spare / wear parts and/or oils & lubricants not specifically recommended in the RMG operating and
maintenance instructions for spare parts. In the event spare / wear parts and / or lubricants & oils other than those
specifically recommended are used, RMG shall not be held liable for any defects and/or consecutive damages
attributable to such use of illegal parts, lubricants, oils etc.
Item numbers mentioned in the specific operating and maintenance instructions correspond with the numbers in the
spare parts lists and drawings.
Some parts in the lists and drawings are marked with a letter “W”. We recommend to always have a reserve of those
parts in stock for maintenance purposes.
Those spare parts are put together in another separate list at the end of the spare parts list.
1.1 Safety information
In this manual, safety information is highlighted by means of the following signal words and eye catchers:
324.20 p.04
2. Specific maintenance instructions
2.1 Valve stem (78/178)
In order to secure the diaphragm (as applicable: 58 or 58* / 158 or 158*) against unintentional movements when loosening
and / or tightening the nuts (54, 65 / 154, 165 resp.), be sure to secure the valve stem accordingly. The valve stem
(78/178) can be gripped with a wrench for that purpose.
2.4 Tightening torques MA
Screws & bolts – item no. 10 110 60/160 72/172
Tightening torques in Nm 20 15 20 8
Components Lubricants RMG part no.
All O rings and locking rings (51/151) Silicone grease 27081
All fastening screws and screwed pipe connections Assembly paste 27091
2.5 Lubricants
2.2 Valve discs (as applicable: 66, 77 / 166, 177)
With valve disc (77/177) closed, adjust valve disc (66/166) by turning hex collar nut (65/165) and hex nut (79) or special nut
(179) in such a way that both valve discs (66, 77/66, 177) sit equally well in their respective valve seats.
2.3 Diaphragm (as applicable: 58 or 58*, 158 or 158*)
Set the valve stem (78/178) with the valve discs (66, 77/166, 177) to a 100 % aperture. Then tighten the hex collar nuts
(65/165) so that the diaphragm (as applicable: 58 or 58* / 158 or 158*) will not move unintentionally.
Should it be necessary to replace diaphragm (58/158) and/or sealing ring (59/159), be sure to replace BOTH by installing
a new diaphragm (58*/158*) with integrated sealing ring. Pay good attention to correct fitting position of diaphragm (58*/158*)
inside diaphragm housing UT (74/174). With valve discs closed (66, 77/166, 177), be sure to install diaphragm (58*/158*) in
such a way that its bulge protrudes from diaphragm housing UT (74/174) and above the contact line with diaphragm housing
OT (53/153). See the sectional drawing – items 4.3.1 and 4.4.1.
Danger!! Do not carry out maintenance unless the system is safely depressurised.
324.20 p.05
3. Specific operating instructions
RMG retrofit kit 12133693
Denomination Part no.
Threaded pin (setscrew) 101195
Screwed connection 31950
Union nut 30804
Cutting ring 30904
How to retrofit – proceed as follows:
– Unscrew the plug (12/112).
– Visually check the stepped bore: Any dirt? Obstructions? Remove and clean as required.
– Screw down the threaded pin (13/113) – all the way to the stop.
– Install the screwed connection (14, 15, 16 / 114, 115, 116). Make sure the elastomer seals are not damaged.
– Installation of the pipes of the measuring line (Ø =12 mm). Install the measuring line as described
in RMG’s general operating manual for gas pressure regulators and safety devices.
3.1 Fitting position
RMG 324 is a zero-pressure gas regulator. Be sure to fit this equipment in a horizontal position
with the spring dome DOWN. See sectional drawings 4.1.1 and 4.2.1.
3.2 Vent line connection
Never plug up the vent line connection.
Be sure to connect a vent line here (thread G 3/8), whenever there is a danger that failure of the
regulator (e.g. measuring diaphragm is damaged) releases gas to the environment.
3.3 Dirt traps (gas filters)
The user must equip the system with devices that protect the gas pressure regulator against contamination.
3.4 Setting the setpoint
To adjust the reference: turn the setpoint adjuster (67/167) clockwise (SW 13) to increase the setpoint.
Turn it ccw to decrease the setpoint.
3.5 Switching from internal to external measuring impulse connection (retrofit)
The RMG 324 comes with a standard internal measuring impulse connection. It is possible, of course, to retrofit for
an external connection if necessary for technical reasons. You will need the following RMG retrofit kit:
3.6 Switching from external to internal measuring impulse connection (retrofit)
Proceed as described for internal -> external retrofit but in reverse order (see 3.5). Make sure all retrofit parts are in good
condition. Replace with better ones, if and where necessary.
If your RMG 324 gas pressure regulator came with an external measuring impulse connection, you will need a plug (12/112)
for retrofit (RMG part no. 100851).
Note
Caution!!
Danger!!
324.20 p.06
4.1.1 Spare parts drawing for main valve RMG 324 – DN 65, DN 80, DN 100 (Drawing shows required fitting position – spring dome DOWN)
MA Be sure to comply with tightening torques in table on page 4.
W Parts should be held in stock for maintenance purposes.
B
B
1
W2
W2
W3
4 (glued)
B – BVersion with internal pd –
measuring impulse connection
B – BVersion with external pd –
measuring impulse connection
MA
15, 16 14 13
10
11
12 10
11
MA
Item Part no. no. Denomination Number W Materials DN 65 DN 80 DN 100
324.20 p.07
4.1.2 Spare parts list for main valve RMG 324 – DN 65, DN 80, DN 100
1 Main valve body 1 GLM 10031282 10030741 10031223
2 O ring 3 W KG 20461 20246 20518
3 O ring 1 W KG 21177 21177 21177
4 Measuring tube 1 NSt 10031286 10030788 10031227
10 Hex nut 4 St 5559 5559 5559
11 Washer 4 St 14153 14153 14153
12 Sealing cap 1 St 100851 100851 100851
Items 13 to 16 of RMG retrofit kit 1 St/NSt 12133693 12133693 12133693
13 Threaded pin (setscrew) 1 NSt 101195 101195 101195
14 Screwed connection 1 St 31950 31950 31950
15 Union nut 1 St 30804 30804 30804
16 Cutting ring 1 St 30904 30904 30904
W Parts should be held in stock for maintenance purposes.
German abbreviations stand for the following materials:
St ... steel LM ... light metal / alloy GMs ... cast brass
NSt ... stainless steel Ms ... brass GZn ... cast zinc
FSt ... spring steel GS ... cast steel AlBz ... aluminium bronze
NFSt ... stainless spring steel GGG ... spheroidal graphite cast iron K ... synthetic materials
Bz ... bronze GBz ... cast bronze KG ... gummous synthetic materials
Cu ... copper GLM ... cast light metal SSt ... foamed materials
324.20 p.08
4.2.1 Spare parts drawing for main valve RMG 324 – DN 80 – type: part no. 10031423 (Find number on type plate attached to main valve body) (Drawing shows required fitting position – spring dome DOWN)
104 (glued)B
B
101
W 105
W 102
W 102
W 103
B – BVersion with internal
measuring impulse connection
112
111
110
110
111
B – BVersion with external
measuring impulse connection
MA Be sure to comply with tightening torques in table on page 4.
W Parts should be held in stock for maintenance purposes.
MA
113 114 115, 116
MA
Item Part no. no. Denomination Number W Materials DN 80
324.20 p.09
4.2.2 Spare parts list for main valve RMG 324-DN 80 – type: part no. 10031423
101 Main valve body 1 GLM 10030741
102 O ring 3 W KG 20246
103 O ring 1 W KG 21177
104 Measuring tube 1 NSt 10031516
105 Sliding contact bearing 1 W K 101059
110 Hex nut 4 St 5559
111 Washer 4 St 14153
112 Sealing cap 1 St 100851
Items 113 to 116 of RMG retrofit kit 1 St/NSt 12133693
113 Threaded pin (setscrew) 1 NSt 101195
114 Screwed connection 1 St 31950
115 Union nut 1 St 30804
116 Cutting ring 1 St 30904
SW 7
X
This side: valve seat
This side: control spring
Diaphragm housing – body
Diaphragm housing – cap
Diaphragm
324.20 p.10
4.3.1 Regulating assembly RE 2 for DN 65, DN 80, DN 100
MA Be sure to comply with tightening torques in table on page 4.
W Parts should be held in stock for maintenance purposes.
View “X”
66
65
W 64
63
62
(glued) 61
60
W 64
W 59
W 58
57
56
W 55
54
53
W 52
51
50
79
78
77
76 W
75
74
60
72
71
70
69
68
67
MA
MA
SW 13
Item Part no. no. Denomination Number W Materials DN 65 DN 80 DN 100
324.20 p.11
4.3.2 Spare parts list of regulating assembly RE 2 for DN 65, DN 80, DN 100
50 Cap 1 K 26402 26402 26402
51 Sealing ring 1 FSt 19116 19116 19116
52 O ring 1 W KG 20588 20588 20588
53 Diaphragm cap 1 St 10031375 10031375 10031375
54 Hex nut 1 St 13199 13199 13199
55 O ring 1 W KG 18417 18417 18417
56 Spring plate 1 LM 10030750 10030750 10030750
57 Diaphragm disc 2 St 10030749 10030749 10030749
58 Diaphragm 1 W KG 10007115 10007115 10007115
59 Sealing ring 1 W KG 10031387 10031387 10031387
58 * Diaphragm 1 W KG 10031414 10031414 10031414
60 Hex screw 36 St 10065 10065 10065
61 Locking screw 4 St 101409 101409 101409
62 Locknut 1 Ms 101333 101333 101333
63 Valve rod guide 1 K 10031476 10031508 10031493
64 Sliding contact bearing 2 W K 101332 101349 101349
65 Hex collar nut 2 St 13184 13184 13184
66 Valve disc 1 K 10031474 10031512 10031494
67 Setpoint adjuster 1 Ms 10031234 10031234 10031234
from Serial No. 1101xxxxx: Index B
68 Spring plate 1 LM 10031513 10031513 10031513
69 Pressure spring 1 FSt 10031422 10031422 10031422
70 Sealing ring 1 St 19195 19195 19195
from Serial No. 1101xxxxx
71 Threaded adapter 1 K 101201 101201 101201
72 Hex nut 32 St 5559 5559 5559
74 Diaphragm housing 1 St 10030742 10030742 10030742
75 Valve seat 1 LM 10031379 10031373 10031381
76 O ring 1 W KG 21177 21177 21177
77 Valve disc 1 K 10031279 10031275 10031284
78 Valve rod 1 NSt 10031239 10031510 10031229
79 Hex nut 1 NSt 100852 100852 100852
324.20 p.12
4.4.1 Regulating assembly for DN 80 – type: part no. 10031423
MA Be sure to comply with tightening torques in table on page 4.
W Parts should be held in stock for maintenance purposes.
MA
179
178
177
W 176
175
174
173
172
171
170
169
168
167
166
165
163
162
161 (glued)
164
160
159 W
158 W
157
156
155 W
154
153
152 W
151
150
MA
158 * W
Item Part no. no. Denomination Number W Materials DN 80
324.20 p.13
4.4.2 Spare parts list of regulating assembly – type: part no. 10031423
150 Cap 1 K 101061
151 Sealing ring 1 FSt 19116
152 O ring 1 W KG 20588
153 Diaphragm housing UP 1 St 10030743
154 Hex nut 1 St 13199
155 O ring 1 W KG 18417
156 Spring plate 1 LM 10030750
157 Diaphragm disc 2 St 10030749
158 Diaphragm 1 W KG 10007115
159 Sealing ring 1 W KG 10031387
158 * Diaphragm 1 W KG 10031414
160 Hex screw 4 St 10011
161 Locking screw 4 St 12046
162 Locknut 1 Ms 24686
163 Flow cone 1 K 10031277
164 Pipe 4 St 10030796
165 Hex collar nut 2 St 13184
166 Valve disc 1 K 10031276
167 Setpoint adjuster 1 Ms 10031234
from Serial No. 1101xxxxx: Index B
168 Spring plate 1 LM 10030797
169 Pressure spring 1 FSt 10031422
170 Sealing ring 1 St 19195
from Serial No. 1101xxxxx
171 Threaded adapter 1 K 101201
172 Hex nut 32 St 5559
173 Hex screw 32 St 10065
174 Diaphragm housing 1 St 10030742
175 Valve seat 1 LM 10030790
176 O ring 1 W KG 21177
177 Valve disc 1 K 10031275
178 Valve rod 1 NSt 10031278
Item Part no. no. Denomination Number W Materials DN 65 DN 80 DN 100
324.20 p.14
5. Parts for maintenance purposes
2 O ring 1 W KG 20461 20246 20518
3 O ring 3 W KG 21177 21177 21177
52 O ring 1 W KG 20588 20588 20588
55 O ring 1 W KG 18417 18417 18417
58 Diaphragm 1 W KG 10007115 10007115 10007115
59 Sealing ring 1 W KG 10031387 10031387 10031387
58 * Diaphragm 1 W KG 10031414 10031414 10031414
64 Sliding contact bearing 2 W K 101332 101349 101349
76 O ring 1 W KG 21177 21177 21177
Type: part no. 10031423
102 O ring 1 W KG 20246
103 O ring 3 W KG 21177
105 Sliding contact bearing 1 W K 101059
152 O ring 1 W KG 20588
155 O ring 1 W KG 18417
158 Diaphragm 1 W KG 10007115
159 Sealing ring 1 W KG 10031387
158 * Diaphragm 1 W KG 10031414
176 O ring 1 W KG 21177
For More Information
To learn more about RMG´s advanced gas
solutions, contact your RMG
account manager or visit
www.rmg.com
GERMANY
Honeywell Process Solutions
RMG Regel + Messtechnik GmbH
Osterholzstrasse 45
34123 Kassel, Germany
Tel: +49 (0)561 5007-0
Fax: +49 (0)561 5007-107
Honeywell Process Solutions
RMG Messtechnik GmbH
Otto-Hahn-Strasse 5
35510 Butzbach, Germany
Tel: +49 (0)6033 897-0
Fax: +49 (0)6033 897-130
Honeywell Process Solutions
RMG Gaselan Regel + Messtechnik GmbH
Julius-Pintsch-Ring 3
15517 Fürstenwalde, Germany
Tel: +49 (0)3361 356-60
Fax: +49 (0)3361 356-836
Honeywell Process Solutions
WÄGA Wärme-Gastechnik GmbH
Osterholzstrasse 45
34123 Kassel, Germany
Tel: +49 (0)561 5007-0
Fax: +49 (0)561 5007-207
POLAND
Honeywell Process Solutions
Gazomet Sp. z o.o.
ul. Sarnowska 2
63-900 Rawicz, Poland
Tel: +48 (0)65 5462401
Fax: +48 (0)65 5462408
ENGLAND
Honeywell Process Solutions
Bryan Donkin RMG Gas Controls Ltd.
Enterprise Drive, Holmewood
Chesterfield S42 5UZ, England
Tel: +44 (0)1246 501-501
Fax: +44 (0)1246 501-500
CANADA
Honeywell Process Solutions
Bryan Donkin RMG Canada Ltd.
50 Clarke Street South, Woodstock
Ontario N4S 0A8, Canada
Tel: +1 (0)519 5398531
Fax: +1 (0)519 5373339
USA
Honeywell Process Solutions
Mercury Instruments LLC
3940 Virginia Avenue
Cincinnati, Ohio 45227, USA
Tel: +1 (0)513 272-1111
Fax: +1 (0)513 272-0211
TURKEY
Honeywell Process Solutions
RMG GAZ KONT. SIS. ITH. IHR. LTD. STI.
Birlik Sanayi Sitesi, 6.
Cd. 62. Sokak No: 7-8-9-10
TR - Sasmaz / Ankara, Turkey
Tel: +90 (0)312 27810-80
Fax: +90 (0)312 27828-23
RMG 324.20