Ring-spinning machine G 33 Programming.pdf
Transcript of Ring-spinning machine G 33 Programming.pdf
-
Instruction G3305e4
Ring-spinning machine G 33
Programming
Program version V 3.000 V 2.000 V1.18(SCU) (DCU) (BTRI)
09.2001 - en G3305e4 1
-
2 G3305e4 09.2001 - en
-
Index to contents
1. Installation and commissioning of G33 software . . . . . . . . . . . . . . . . . . . . . . . . . . . 61.1. SCU processor module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61.2. Control unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2. General information about the menu system . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72.1. Key-operated switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72.2. Selecting screens . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82.3. Description of programming keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92.4. Messages displayed at start-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92.5. Selecting basic screens . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102.6. Data screen components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112.7. Testing control unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
3. Control unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
4. Mimic panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
5. Control panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
6. Display panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
7. Safety circuit with pilz-type module K20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 158. Comissioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 168.1. First operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 168.2. Cold start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 168.3. Starting up after a warm start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
9. Altering values in a data screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
10. Menu screen and data screens PASSWORD (00) . . . . . . . . . . . . . . . . . . . . . . . . . 1810.1. Password after a cold start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
11. Menu and data screens for PRODUCTION Actual value (10) . . . . . . . . . . . . . . . . . . . 21
12. Menu and data screens for PRODUCTION Setting Speed (11) . . . . . . . . . . . . . . . . . . 2312.1. Speed curve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2512.2. Ring rail position . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
13. Menu and data screens for PRODUCTION Setting Ring Rails (12) . . . . . . . . . . . . . . . . 26
14. Menu and data screens for PRODUCTION On-line Help (13) . . . . . . . . . . . . . . . . . . . 29
15. Menu and data screens for INFORMATION General (30) . . . . . . . . . . . . . . . . . . . . . 31
16. Menu and data screens for INFORMATION Logs - Statistics (31) . . . . . . . . . . . . . . . . . 32
17. Menu and data screens for SET-UP VALUES General (40) . . . . . . . . . . . . . . . . . . . . 3217.1. Unit change-over . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3317.2. Switching languages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
18. Menu and data screens for SET-UP VALUES Configuration (41) . . . . . . . . . . . . . . . . . 35
19. Menu and data screens for SHIFT SCHEDULE (50) . . . . . . . . . . . . . . . . . . . . . . . 37
Programming
09.2001 - en G3305e4 3
-
Programming
4 G3305e4 09.2001 - en
-
20. Menu and data screens for TESTS Standard Machine (71) . . . . . . . . . . . . . . . . . . . . 38
21. Menu and data screens for TESTS ROBOdoff - SERVOdisc (72) . . . . . . . . . . . . . . . . . 40
22. Menu and data screens for TESTS Input - Output (73) . . . . . . . . . . . . . . . . . . . . . . 41
23. Menu screen and data screens TEST cold start - warm start (74) . . . . . . . . . . . . . . . . . 42
24. Clearing messages, malfunctions and warnings . . . . . . . . . . . . . . . . . . . . . . . . . . 4324.1. Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4324.2. Malfunctions after emergency shutdown or power cut . . . . . . . . . . . . . . . . . . . . . . . 4524.3. Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Programming
09.2001 - en G3305e4 5
-
1. Installation and commissioning of G33 software
+ Configuration of control system SCU G3306
The 2 EPROMs on the control system and the 2flash memories on the control unit must matchand are therefore normally changed at the sametime.
1.1. SCU processor module
The EPROMs of the machine control system are onthis module. They contain the operating system andthe utilities program.
+ Installation G3306
Key1 = CPU module2 = Label on the EPROM3 = Type of machine4 = Software release designation5 = Software slot designation6 = Drawing number7 = CPU system (control)8 = Checksum
1.2. Control unit
A wrongly mounted flash EPROM (corner!) isdestroyed!Installation of the flash memory DCU-OS (operatingsystem) and DCU-APP (application)+ Installation G3306
Attention!
Attention!
Programming
6 G3305e4 09.2001 - en
-
2. General information about the menu system
2.1. Key-operated switch
Key-operated switchNever leave the key in the switch. This prevents anyunwanted interventions (data changes). The key canonly be removed in automatic position.
Automat
Interventions by machine operator areauthorised.
Most of the data can be viewed but notchanged.
Alter data
(The machine can be in operation)
Interventions by authorised persons are al-lowed.
Maintenance
(The machine must be idle)
Configuration, maintenance jobs and test.
Interventions by authorised persons are al-lowed.
Programming
09.2001 - en G3305e4 7
-
2.2. Selecting screens
+ Description of programming keys Each program has MENU screen and data
screens. The number of MENU screens depends on the
type of machine. The number of data screens also depends on the
type of machine
The description in sub-sections 3 to 7 applies to alltypes of RIETER machines. The illustration below isfor information.
Programming
8 G3305e4 09.2001 - en
-
2.3. Description of programming keys
Forward from MENU screen to MENU screen(10...70)
Backwards from MENU screen to MENUscreen(70...10)
Forward from one data screen to another(10...10.1...10.2...)
Backwards from one data screen to another(10.2...10.1...10...)
Enter key. Save changed or selected va-lues.
Increase variable values or select defaultvalue.Clear malfunction.
Reduce variable values or select defaultvalue.Clear malfunction.
2.4. Messages displayed at start-up
These are system messages which always appearin english at start-up.
Possibly the message 404 Test safety dircuit willappear for 1 to 2 sec.
Programming
09.2001 - en G3305e4 9
-
2.5. Selecting basic screens
When the control unit is started up the basic screen1 appears in the language installed.
Another basic screen can be selected by pressingthe or keys.
The current spindle speed is displayed. The current delivery is displayed The efficiency of the programmed time basis is
displayed.
The current ROBOdoff set position is displayed. The current ROBOdoff actual position is dis-
played. The current ROBOdoff step is displayed.
Machine efficiency = machine availability(rolling efficiency, time base 2, 4, 8 h). Data screen40.4
1 Spindle speed Delivery Efficiency
18000 U/min 20,2 m/min 88,6 %
2 ROBOdoff Set position 3Actual position 3Step 1
Programming
10 G3305e4 09.2001 - en
-
2.6. Data screen components
Key:1 = Page no. (MENU screen, data screen)2 = Lines of text3 = Variable values4 = Current value as calculated
2.7. Testing control unit
To test whether the LEDs and keys of the control unitare functioning properly, proceed as follows: Turn on the main switch and hold down 2 of the
following keys simultaneously (T8, T9, T10, T11,T12, T13, T14).
The test starts.RAM_Test: Main >OK Video >OKROM_Test OK
The LEDs on the control panel are activated indi-vidually.
The LEDs on the control panel are activated toge-ther.
After running the LED test the following wordsappear:- Key = 1 h (hexadecimal)
(epending on key position: 1, 2 or 4)- Static = 0h
(keys STOP, START (2 together))- Matrix = 0h
(the number is shown when the key is struck)
Turn off the main switch.
Spindles Set spindle speedActual spindle speed
without rear bottom roller
Programming
09.2001 - en G3305e4 11
-
3. Control unit
Key:5 = Mimic panel6 = Display panel7 = Control panel
Programming
12 G3305e4 09.2001 - en
-
4. Mimic panel
Key:5 = Mimic panelL1 = Control readyL2 = Automatic modeL3 = WarningL4 = MalfunctionL5 = MaintenanceL6 = Travelling cleanerL7 = Malfunction, control L8 = Malfunction, suction L9 = Emergency shut-down cordL10 = Cord LHL11 = Malfunction in spinning process, headstockL12 = Malfunction in spinning process, tailstockL13 = Emergency shut-down actuatedL14 = Malfunction, safety switch, bottomL15 = Malfunction, ROBOdoff not in neutral positionL16 = Malfunction safety switch, topL17 = Malfunction, ROBOdoff not swung inL18 = Malfunction, press tubes onL19 = Malfunction, SERVOdisc
L20 = Malfunction, Link loading beltL21 = Malfunction, Link unloading beltL22 = Malfunction, ROBOload or LinkL23 = Malfunction, tube monitoring LinkL24 = Malfunction, spindle driveL30 = Cord RHL39 = Gripper disengaged LHL40 = Gripper disengaged RH
Programming
09.2001 - en G3305e4 13
-
5. Control panel
Key:L25 = Travelling cleanerL26 = Speed reductionL27 = ROBOdoffL28 = SERVOdiscL29 = Auxiliary function activeL31 = Active shift no. 1 L32 = Active shift no. 2L33 = Active shift no. 3L34 = Active shift no. 4L35 = Active shift no. 5L36 = Active shift no. 6L37 = Active shift no. 7L38 = Active shift no. 8
T8 = STOP buttonT9 = Select functionT10 = Upwards movementT11 = Downwards movementT12 = Outwards movement or CWT13 = Inwards movement or CCWT14 = START buttonT15 = Safety switch (invisible)T16 = START buttonT17 = Select shiftT19 = Button to activate auxiliary function60 = Key-operated switchT20 = Switch position AUTOMATIC modeT21 = Switch position INPUT modeT22 = Switch position MAINTENANCE modeCW (UZ) = Clockwise CCW (GUZ) = Counter-clockwise
6. Display panel
Key:6 = Textual display panelT1 = MENU screen backT2 = DATA screen backT3 = DATA screen forwardsT4 = MENU screen forwardsT5 = Minus key (decrease value)T6 = Plus key (increase value)T7 = ENTER (save changes)T18 = Select language (all languages saved with
yes are available)
Programming
14 G3305e4 09.2001 - en
-
7. Safety circuit with pilz-type module K20
The safety circuit is actuated either by the EMER-GENCY SHUTDOWN button and the two cord swit-ches (S20, S21) or by a software emergency shut-down.
Pressing the emergency shutdown button or pul-ling the cord (S20 and/or S21) throws the safetyrelay (K20) out of its self-locking position. Thepilz-type module prevents the machine fromstarting up independently after the emergencyshutdown button or cord switch has been relea-sed.The machine performs the emergency stop proce-dure in two stages. First, the frequency inverter(U1 spindle drive) is disabled. The frequency in-verter starts to decelerate the machine as quicklyas possible to zero revs. This process is comple-ted after max. 20 seconds (20) and the pilz-typemodule then switches off all the contactors be-tween the motors and frequency inverters (settingon module (20)). This ensures that no drive is ableto rotate any more. If the emergency shutdownbutton and/or the cords (S20/S21) are releasedand the two START buttons (T14) or the acknow-ledgement button (T6) are pressed, the safetyrelay (K20) returns with K27 to its selflocking po-sition and at the same time the safety circuit istested. To actually start up the machine, actua-te the two START buttons (T14) a second time.
The safety circuit is tested by running the Testsafety circuit every time the machine is switchedon, before every doffing procedure, after an emer-gency shutdown has been acknowledged (emer-gency shutdown button, cord (S20, S21) or soft-ware emergency shutdown).
On the front of the pilz-type module (K20) thereare some LEDs which indicate the current machinestatus.
The LED combinations and their signification are asfollows:
Key:
1 = normal operation operating
2 = emergency shutdown actuated module time 20 sec. countdown
3 = emergency shutdown status
4 = emergency shutdown cleared, error not yet acknowledged on control panel
n = LED lights upo = LED does not light up20 = Time setting
Programming
09.2001 - en G3305e4 15
-
8. Comissioning
8.1. First operation
After installing a new program (EPROM), the ope-rator follows step by step instrucions for the coldstart program displayed on the control panel.
The ring-spinning frame cannot be started upuntil all the data screens have been processed. Itis highly advisable to overwrite the default valuesby the required data.
8.2. Cold start
Procedure: Turn off the main switch. Remove the battery of the SCU control If necessary install the new program (SCU and
operation) Turn on the main switch Wait for the SCU control to start and check the
LED on the base printed circuit of the SCU control.+ Instruction G3306
Insert the battery of the SCU control. Put the key-operated switch to . Only forwards using key is possible. Enter all the data in order. The data screens can
be worked through backwards as long as the datainput has not yet been terminated by the basicscreen.
Work through all the data screens. Automatic se-quence. (40.2, 40.1, 40.3, 41.1, 41.2, 41.3, 41.6,41.7, 41.8, 41.9, 11.1, 11.2, 11.3, 11.4, 12.5, 11.5,11.6, 12.1, 12.2, 12.3, 12.4, 12.6, 12.7, 12.8, 12.9)= basic screen
The initialisation is now complete.
After every cold start, the textile laboratorymust check the yarn values, as incorrect pro-gramming may lead to the production of faultyyarn.
Incorrectly entered data can now be corrected.
Other data corrections are now possible in all datascreens provided the key is in input position andthe password protection is open.
The ring-spinning machine can now be put into ope-ration in MAINTENANCE or AUTOMATIC operatingmodes.
Make a note of all the data entered at a cold start.The machine card (sample on last page of thisInstruction manual) must be kept constantly up-to-date on every ring-spinning machine and for everyyarn.
The current machine card is kept in the pocket ofthe electrics cubicle on each ring-spinning machine.
Performing a cold start The ring rails are in cops change position (71.3). The ROBOdoff is in basic position. The SERVOdisc is in doffing position.
(or later MAINTENANCE forwards)MAINTENANCE Data screen 74.1
Select Cold start with/withoutSelect Restart yes. ENTER.
Display: No communication The diode (L3) s is red (cold start in progress)If unlit: (this may take a few seconds)AUTOMATICDisplay: 244 Check panel text 0 or 7
acknowledge with +Display: Cold start INPUT Check all data screens and
correct (13.6)Display: Standard screenAUTOMATIC acknowledge the messages with +STARTDisplay: Check panel data /8
Acknowledge with +START Start spinning
3 COLD START Key switch after input
Attention!
Attention!
Programming
16 G3305e4 09.2001 - en
-
8.3. Starting up after a warm start
The machine parameters are stored in the batterybuffered data area of the control and are loaded backinto the work area of the CPU when there is a warmstart.
The machine is ready for operation after controlrun-up is finished.
9. Altering values in a data screen
Key:3 = Variable values
Key position:AUTOMATIC All MENU and DATA screens can be viewed.
No values can be changed.
The keys can be used to selectthe required DATA screen.
INPUT (insert the key and turn ) In this data screen you can use the key to
direct the cursor > to the value to be changed.
This value can be changed using the or key.The changed value is indicated by >
-
10. Menu screen and data screens PASSWORD (00)
As an additional protection against unintentional datachanges there is a password for data screens 11.1and 11.2, 13.3, 13.4 and 13.5.
To access password protection, the key switch mustbe in the INPUT position en enter the password.
View: AUTOMATIC, INPUT, MAINTENANCE
To access the blocked parameters, proceed as fol-lows:
To enter the password:Enter the password using the , and keys. Any number of attempts is possible.
To check the password:To check the password, press ENTER to put thecursor onto the 3rd line. Use the or key tochange to Check. Confirm by pressing the key.
When the correct password is entered the displaychanges to:
If an incorrect password is entered the display chan-ges to:
To activate password protectionThere are 3 possibilities for preventing access to theparameters: incorrect password turn key switch wait 5 minutes
Enter: INPUT
Input Check Change
00.1 Enter passwordPassword >
password protection ON0 00000
Input
00 PASSWORD
00.1 Enter passwordPassword
> password protection OFFCheck0 00000
00.1 Incorrect passwordPassword
> password protection ONCheck0 00000
Programming
18 G3305e4 09.2001 - en
-
To change the password:There are 6 steps necessary to change the pass-word. If password protection is already deactivated(message at bottom right: Password protectionOFF) you can start at step 3.
1.) Enter the old (still valid) password using the , and keys. Any number of attempts is possible.
2) To check the password, put the cursor on the3rd line and either: move from Input to Check in the display. ENTER.
If the wrong password is entered the following displayappears:
Either start again at step 1or move from Input to Change and confirm with .
When the correct password is entered the follo-wing display appears:
Continue with step 3.
If an incorrect password is entered the followingdisplay appears and you must go back to step 1.
3) Enter the new password using the , and keys. Any number of attempts is possible.
4) To change the password, move the cursor tothe 3rd line and go from Input to Change.Confirm with the key. 2nd line = Enter new password again.
00.1 Enter passwordPassword
> password protection OFF
00.1 Incorrect passwordPassword
password protection ON
0 00000
Input0 00000
Check
00.1 Enter new passwordPassword
> password protection OFF0 00000
Input
00.1 Enter passwordPassword
password protection ONInput0 00000
Programming
09.2001 - en G3305e4 19
-
If the password protection is deactivated: the following prompt appears in the 1st line: Enter
the new password once again. Continue with step 5.
If the password protection is activated: the following prompt appears in the 1st line: Incor-
rect password Go back to step 1.
5) Enter the new password using the , and keys. Any number of attempts is possible.
6) To change the password definitively move thecursor to the 3rd line and go from Input to Change. Confirm with the key.
If the same new password was entered again in step 5: the following message appears in the 1
st line:
Password changed. This means that the newpassword is valid at once.
If the password entered the 2nd time in step 5 wasnot the same, then: the message incorrect password appears in the
1st line . Go back to step 1.
10.1. Password after a cold start
After a cold start with data reset, the password is0 0 0 0 0 0.
Programming
20 G3305e4 09.2001 - en
-
11. Menu and data screens for PRODUCTION Actual value (10)
View: AUTOMATIC, INPUT, MAINTENANCE
Current shift default 1Min./Max. value: 1 - 8Production default 0.00 kmMin./Max. value: 0.00 - 99999.99Efficiency default 100.0%Min./Max. value: 0.0 - 100.0%
Last shift default 1 2 3 4Option: 1 2 3 4 or 5 6 7 8 with orProduction default 000kg/lbsMin./Max. value: 000 - 9999999Efficiency default 100.0%Min./Max. value: 0.0 - 100.0%
Total shifts default 1 2 3 4Option: 1 2 3 4 or 5 6 7 8 with orProduction default 000 kg/lbsMin./Max. value: 0 - 99999.99
Enter: INPUT (change values)
Efficiency: Duration of production with doffing sin-ce shift began, divided by produced time (minusmachine downtimes).
Choice: km/kg or hank/lbs. Unit 40.3Efficiency: Production duration with doffing since be-ginning of shift divided by produced time (minusmachine downtimes).
Choice: km/kg or hank/lbs. Unit 40.3
10 Production actual values
10.1 Current shift 1Production 12345,67 kgEfficiency 98,6 %
10.2 Last shiftsProduction 000 000 000 000 kgEfficiency 100,0 100,0 100,0 100,0 %
1 2 3 4
10.3 Total shiftsProduction 000 000 000 000 kg
1 2 3 4
Programming
09.2001 - en G3305e4 21
-
Machine production default: 0 kgMin./Max. value: 0 - 99999.99Machine efficiency default: 100.0%Min./Max. value: 0.0 - 100.0 %Delete default noOption: no, yes
Reset machine production default: noOption: no, yesDate of the last shift: ...display
Production of total shift default: noOption: delete shift no, yes
Choice: km/kg or hank/lbs. Unit 40.3
Machine efficiency = machine availability (rolling ef-ficiency, time base 2, 4, 8 h).
1 - yes, 2 - yes, 3 - yes, 4 - yes, 5 - yes, 6 - yes,7 - yes, 8 - yes
10.5 Delete production total (menu 10.3)of all shiftslast deleted : 19.02.97
no
10.6 Delete production total (menu 10.3)of the shift 0,01 kg1-no
10.4 Machine production 0 kgMachine efficiency 100 %delete 19.02.97 no
Programming
22 G3305e4 09.2001 - en
-
12. Menu and data screens for PRODUCTION Setting Speed (11)
View: AUTOMATIC, INPUT, MAINTENANCE
Yarn count default: 40.0 NeMin./Max. value: 3.0 - 410Total draft default: 40.00Min./Max. value: 5,00...120,00Break draft default: 1.19Min./Max. value: 1.04 - 1.60
Twist default: 9 T/mMin./Max. value: 10...6300Twist coefficient default: 1 a/mMin./Max. value: calculatedCorrection twist contraction default: 5.0%Min./Max. value: 0.0 - 15.0%
The set % twist contraction raises the total draftentered.This setting does not affect the total draftdisplayed.
Speed at spinning start up default: 85%Min./Max. value: 60% - bottom speed
Spin-out speed calculatedSpindle slip correction default: 0.0%Min./Max. value: 0.0 - 6.0%
Enter: INPUT (11.1 and 11.2 with password)
Current yarn count (for calculating production rate)
Current total draft (without twist contraction)
G0002 (Mechanical setting, not electronic)
So that the machine does not start up without data input.Current yarn twist
Current twist coefficient
Standard setting:tricot = 5%, weft = 7%, warp = 9%The delivery measured at the front bottom rollercorresponds to 100% = display.In the shift counter the delivery measured at the frontbottom roller is stored minus the twist contraction(shorter thread).
Standard setting: Ne 50 = 80...86%
With spindle tape Habasit W8 = 0%This setting affects the speed of the spindle drivemotor and the pulley shaft. The spindle speed mea-sured with a stroboscope should correspond to thedisplay. The display is rounded off to 100 nSp.
11 Production Setting speed
11.1 Yarn count NeTotal draftBreak draft
40,0
1,1940,00
11.2 Twist T/mTwist coefficient a/mCorrection twist contraction %
9
5,0
1
11.3 Speed at spinning start up %Spin-out speed rpmSpindle slip correction %
85
0,0
Programming
09.2001 - en G3305e4 23
-
Bottom speed default: 90%Min./Max. value: Speed at spinning start up.100%RR-position default: 46.0 mmValue 42.0...56.0 mmAverage spindle speed calculated
Top speed default: 14000 U/minMin./max. value: 3000...30000
1st RR position top speed default: 100.0 mmMin./max. value: 100.0 ... 152.0 mm2nd RR position top speed default: 172.0 mmMin./max. value: 101.0 ... cops full
Start suction unit default: beforeOpo: before, after
Delay drafting arrangement after intermed. STOP default: 0,3 sec.Min./max. value: 0,0...2,9 sec.Delay drafting arrangement after cops change default: 0,6 sec.Min./max. value: 0,0...2,9 sec.
Standard setting: Ne 50 = 80...86%
Standard setting: Ne 20 = 42...56 mm
Display
The maximum rated spindle speed will be found inthe spinning schedule and should be chosen accor-ding to the material being processed and the ringtravellers used,
From these various end-break counts (spread overthe entire cops formation) you can determine themost suitable position for the 1st and 2nd top spindlespeed. Standard: 1st top speed = 40 ... 80 ... cops full -2mmsetting 2nd top speed = cops full -1 ... 20 mm
The vacuum is built up befor the spindle start-up istriggered by Start suction. This suppresses theformation of lap during the spindle start.
Standard setting: 0,3...0,5 sec.
Standard setting: 0,3...0,8 sec.
11.6 Start suction unitDelay drafting arrangement after intermed. STOP sDelay drafting arrangement after cops change s
before spindle start0.3
11.4 Bottom speed % of max.RR position mmAverage spindle speed rpm
9046,0 0
11.5 Top speed rpm1st RR position top speed mm2nd RR position top speed mm
14000
172,0
100,0
0.6
Programming
24 G3305e4 09.2001 - en
-
12.1. Speed curve
Key:1 = Spindle speed (%)2 = Spinning start-up speed (%)3 = Bottom spindle speed (% and mm)4 = RR position 1st top speed 100% (mm)5 = RR position 2nd top speed 100% (mm
6 = Spinning out speed 95%8 = Ring rail lift cop base (spinning ring x 0.9)9 = Ring rail lift (spinning ring x 1.15)10 = Ring rail height
12.2. Ring rail position
Key:1 = Spinning tube length (e.g. 200 mm)2 = Limit switch at bottom (S27)
(clamping crown open, S27 not acknowledged)3 = Nipping thread at RR-position (open)5 = Cops change in RR position6 = Spinning start-up RR position
7 = START spindle in RR position8 = Snarl lift reversal point9 = Lock out travelling cleaner in RR position11 = Cops full in RR position12 = Top bunch at RR position13 = Limit switch at top (S26)
Programming
09.2001 - en G3305e4 25
-
13. Menu and data screens for PRODUCTION Setting Ring Rails (12)
View: AUTOMATIC, INPUT, MAINTENANCE
Spinning start-up RR position default: 10 mmMin./Max. value: 2 - 30 mmShape cops base default: mediumOption: flat, medium, roundRR position absolute (display)Value: -10.0 to 260.00 mm
Start spindle in RR position default: 70.0 mmMin./Max. value: 10.0 - 100.00 mmStart spindle after cops change default: downwardsOption: downwards, upwards
BR positionSnarl lift reversal point default: 80 mmMin./Max. value: 10.0...120.0 mmSnarl lift switchover point default: 38.9 mmMin./Max. value: 14.0 - 38.9 mm
Enter: INPUT
Standard setting: 6...11 mm. Must be less than the copschange position data sreeen 12.5Standard setting: medium
If the ring rail position is less than 0 the minus sign isindicated by the number 9, e.g. 905 = -5 mm)
Standard setting: 70...50 mm
Standard setting: downwards movement = 10...30 mmafter reversal point(on upwards movement = 2...20 mm before reversal point)
Standard setting: 80...50 mm
This is the point of switching over from rapid down-wards movement of the ring rails to the normal ringrail spinning movement. It affects the end-breaks atspinning start-up.The positions snarl lift reversal point (12.3),start spindle at RR position(12.2), and snarllift reversal point (12.3) affect the end-breaks atspinning start-up. Choose the positions so that the thread windings ofthe 1st downwards motion are covered by the follo-wing normal RR movement.
12.3 RR positionSnarl lift reversal point mm
mm80,038,9
12 Production Setting ring rails
12.1 Spinning start-up RR position mmShape cops baseRR position absolute
10.0medium
12.2 Start spindle in RR position mmStart spindle after cops change
70.0downwards
0.0
Programming
26 G3305e4 09.2001 - en
-
Snarl lift RR speed upwards default:35 mm/secMin./Max. value: 10 - 50 mm/sSpeed downwards default: 35 mm/secMin./Max. value: 10 - 50 mm/s
Lock out cleaner at RR position default 179 mmMin./Max. value: 100 - 250 mm
Cops full at RR position default 187 mmMin./Max. value: 100 - 250 mmCops change at RR position default 5 mmMin./Max. value: 5 - 30 mm
Top bunch default: noMin./Max. value: no, yesTop bunch at RR position default: 190 mmMin./Max. value: copy cops full...copy tube lengthLength of top bunch default: 244 mmMin./max value: 100 to 422 mm
Number of back windings default: 2.5 bWMin./Max. value: 1.0 - 5.0 bW
Length of nipping thread default: 0.5 turns
Min./Max. value: 0.1 - 2.5 turns
Underwindings per RR pulse default: 5 mmMin./Max. value: 10 - 0 mm
Standard setting: 35 mm/sec
Valor indicativo: 35 mm/segIf double ballooning occurs raise value to maximum50 mm/sec.
Standard setting: 5 50 mm less than cops full.The travelling cleaner must be in the parkedposition before cops full.Standard setting : 5 8 mm before tube end
Standard setting: 5 6 mm above tube seatThis value must be less than the spinning start-upposition, Data screen 12.1
If no = cops full +1 mm
Standard setting: : 5 ... 8 mm before Tube end
Always enter sufficient length of top bunch otherwisethe number of end-breaks at spin-out will increase.
Standard setting: Cotton 2.0 bwBlends 1.5 bw
Standard setting: 0,5...0,8 turns(Never more than 1 turn effective)(Option DIL switch S2/ON results in max. 10.0turns) + G3306
Standard setting: -5...-6 turns
12.5 Lock out cleaner at RR position mmCops full at RR position mmCops change at RR position mm
12.6 Top bunchTop bunch at RR position mmLength of top bunch mm
12.7 Number of back windings bwLength of nipping thread turnsUnderwindings per RR pulse mm
179,0
5,0
187,0
no
422190,0
2,5
5,0
0,5
12.4 Snarl lift RR speedUpwards mm/secDownwards mm/sec35,0
35,0
Programming
09.2001 - en G3305e4 27
-
Height RR pulse default: 1.15Min./Max. value: 1.00 - 1.25Cops weight default: 38.0 gMin./Max. value: 10.0 - 300.0 gLength per RR pulse default: automaticMin./Max. value: 3.0 - 7.0 mEach time the yarn count (11.1) changes, thelength of the ring rail cycle is automatically adjusted.The automatically adjusted ring rail cycle can becorrected manually to the desired value.
Back winding RR speed default: calculatedRing rails position brake motor default: 105 mmMin./Max. value: 0 - 250 mm
Cops diameter top default: 0%Min./max. value: -18 to +18%%
Standard setting: 1,15(is a factor and does not mean grams)
Stand. sett:Ne 7...30 / Nm 12...50 = 3,4...4,0 mNe 30...50 / Nm 50...85 = 4,4...4,7 mNe 40...80 / Nm 70...135 = 5,2...5,6 m
Standard setting: defaultThe setting of this value affects the spinning start-upprocedure. The end-breaks at cops change may beaffected. This value is calculated on the basis of thetube length as entered.
Cop formation resembling a cylindrical shape. Press the minus key (T5) to reduce the value.
The cops get thinner at the top. Press the plus key (T6) to increase the value.
The cops get thicker at the top.
Target is: Cops diameter at top 0.5 to 1.0 mm less than
at the thickest point. Cops diameter max. with
coarser = Ne 30 = spinning ring minus 2.5 to 3.5 mm
finer = Ne 32 = spinning ring minus 2.0 to 2.5 mm.
12.9 Back winding RR speeddownwards mm/secRing rails position brake motor mm105,0
12.8 Height RR pulse ring diameter xCops weight gLength per RR pulse m
1,15
4,638,0
12.10Cops diameter top %0
Programming
28 G3305e4 09.2001 - en
-
14. Menu and data screens for PRODUCTION On-line Help (13)
View: AUTOMATIC, INPUT, MAINTENANCE
Premature spin-out default: noOption: no, yesManual speed reduction default: 10%Min./Max. value: 0 - 30%Speed reduction time default: 10 minMin. / max. value 0...20 minData screen 13.2 Setting ON / OFF + G3306(DIL switch S2/3 Off = data screen 13.2 is not dis-played)
Start traveller running-in programme default: noOptions: no, yesTraveller running-in duration default: 4.0 hMin. / max. value 0.0...50.0 hDecreasing speed default: 5 %Min. / max. value 0...20 %Data screen 13.3 with protected password
Spinning-out speed adjustment default: 100%Min./max. value: 50% ... 200%Wait for spindles to come to a standstillin RR pos. 0" display
Enter: INPUT (13.3, 13.4 and 13.5 with password)
Only enter if ring-spinning frame is producing
Standard setting: 8...12%
Yes in the key position AUTOMATIC(can be selected without key)Programming with key
Standard setting: 5 10%
The settings in data screen 13.3 affect the copschange-end breaks. Setting: Clamping crown closed and another 1 ... 5turns of the spindle = 0.1...0.6 sec.Note:The spin-out speed adaptation affects the threadlength between the clamping crown and the ringtraveller. (TITAN 104 to 106%, ORBIT and ZENITH100%). The thread length between the clampingcrown and the ring traveller should be such that thethread running diagonally to the spinning ring duringcops change does not get trapped underneath thespinning tube.
13 Production On-line Help
13.1 Premature spin-outManual speed reduction %Speed reduction duration min
no1010
13.2 Start traveller running-in programTraveller running-in time hReduction of speed %
no4.05
13.3 Spinning-out speed adjustment %Wait for spindles to come to a standstill in RR pos. 0"
1000,0 s
Programming
09.2001 - en G3305e4 29
-
Data screen 13.4 with password protection.Twist adjustement during the stopping process
default: 100 %Min./max.-value: 50...200 %Pre-turn spindles default: yesOptions: yes, noWait for spindle standstill at RR pos. 0
default: yesOptions: yes, noData screen 13.5 with password protection.
Lower delivery roller start-delayed activeDefault: noSelection: yes, noThe time specified is 0.5 secBraking intermiediate stop Default: normalMin. / max. value normal, fast
Data screen 13.6 with password protection andDIL switch S2/2, Setting ON/OFF + G3306
Direction o rotation of spindles Default: inactivSelection: inactive, S, ZStop ROBOdoff at step 25 Default: noSelection: yes, no
Data screen 13.7 with password protection andDIL switch S2/6, Setting ON/OFF + G3306
Acceleration of spindles Default: 4.5 sec.Min. / max. value 3.8...6.0 sec.
Caution: Where the set yarn count (data screen11.1) and the twist (data screen 11.2) are correc-ted by more than 5%, the twist adaptation is resetto 100%!
Standard setting: yes
The cops change position is approached only whenthe spindles are at a standstill.
Start delay is active yes following turn mainswitch On and Reduce drafting system pressure.During a short machine STOP (e.g. doffing), thedrafting system delay is not activated.
If fast breaking is selected, the motors brake im-mediately, in the same way as during anEMERGNCY STOP.
If data screen 13.5 is inactive, the direction of rotationof the spindle is Z (not optional).In the case of yarns that are difficult to detach (e.g.elastic core yarn) select yes so that the ROBOdoffstops at step 25 and the yarn can be cut with scissors.
This setting affects the end-breaks at start-up aftercops change.Standard setting:Ne 36 160 Time: 4.5 3.8 secNe 36 5.5 Time: 4.5 6.0 sec
13.4 Yarn twist adjustment during spin-out %Pre-turn spindlesWait for spindle-stop at RR-pos. 0
100
yes
yes
13.5 Lower delivery roller: start delay active 0.5 sec.Braking intermediate stop
no
normal
13.6 Direction o rotation of spindlesStop ROBOdoff at step 25
inactivno
13.7 Acceleration of spindles 4.5 s
Programming
30 G3305e4 09.2001 - en
-
15. Menu and data screens for INFORMATION General (30)
View: AUTOMATIC, INPUT, MAINTENANCE
Time and date = setting in data screen 40.1
Record of type of machineSetting ON/OFF + G3306, DIL switch S2/1Program version SCU displayProgram version DCU displayProgram version BTRI display
Enter: no possibility
Machine programUser programOperating system controls
30 Information General
30.2 Time Data
17:00 10.12.97
30.3 Ring-spinning machine : G33Program version : V3.000 V2.000 V1.18
(SCU) (DCU) (BTRI)
Programming
09.2001 - en G3305e4 31
-
16. Menu and data screens for INFORMATION Logs - Statistics (31)
View: AUTOMATIC, INPUT, MAINTENANCE
Malfunction code default: 1 or last malfunction code selected
Min./Max. value.:: 1...100X = additional notes
Enter: INPUT
Select the log number required by selecting or .
17. Menu and data screens for SET-UP VALUES General (40)
View: AUTOMATIC, INPUT, MAINTENANCE
Time system default: 24hMin./Max. value: 12 h, 24hHour default: 17Min./Max. value: 0 - 23Minute default: 34Min./Max. value: 0 - 59Day default: 6Min./Max. value: 1 - 31Month default: 9Min./Max. value: 1 - 12Year default: 1997Min./Max. value: 1980 - 2020
Enter: INPUT
31 Information Logs - Statistics
31.1 Log no 10.12.1997 17:111002217 Temp. draft motors tailstock F60/F611
X
40.1 Time systemTime :Date . . Monday
1712
2905 1997
24h
40 SET-UP VALUES General
Programming
32 G3305e4 09.2001 - en
-
Language options default: all activeOption: 12
Yarn count unit default: NeMin./Max. value: Ne, Nm, TexUnit of measurement default: metricMin./Max. value: metric, imperialUnit of measurement default: units of lengthOption: units of length, units of weight
English is always active
17.1. Unit change-over
Ne Nm Tex metr. imperial Length Weight GB1Speed
GB1Delivery
10.xProduction
11.1Yarn count
11.2Twist
11.2Coefficient
rpm y/min lbs tex tpi a e
rpm y/min hank tex tpi a m
rpm m/min kg tex T/m a e
rpm m/min km tex T/m a m
rpm y/min lbs Nm tpi a e
rpm y/min hank Nm tpi a m
rpm m/min kg Nm T/m a e
rpm m/min km Nm T/m a m
rpm y/min lbs Ne tpi a e
rpm y/min hank Ne tpi a m
rpm m/min kg Ne T/m a e
rpm m/min km Ne T/m a m
40.2 Italien Greek RussianGerman Spanish Turkish ChineseFrench Portuguese Czeck Japanese
onon
onon
ononon
ononon
on
40.3 Yarn count unitUnit of measurementProduction in units of length
metricNe
Programming
09.2001 - en G3305e4 33
-
17.2. Switching languages
Continuation Menu screen and data screen SETTINGS general (40)Time basis Machine efficiency
default: 8 h Option : 2 h, 4 h, 8 h
Select standard overview screen default: machine
Option: machine, ROBOdoff
40.4 Time basis Machine efficiency h8
40.5 Select standard overview screenMachine
LanguageGB1Speed
GB1Deliverymetr.
GB1Deliveryimperial
11.2Twistmetr.
11.2Twistimperial
11.xSpeed
12.7Back-windings
12.7Lengthofnippingthread
71.1Speed
de U/min m/min y/min U/m tpi U/min HW U U/min
en rpm m/min y/min T/m tpi rpm BW T rpm
fr tpm m/min y/min t/m tpi tpm AR T tpm
it g/min m/min y/min U/m tpi g/min AP U g/min
sp RPM m/min y/min t/m tpi RPM EP R RPM
tr D/dak m/dak y/dak T/m tpi D/dak KS T D/dak
pt R/min m/min y/min R/m tpi R/min ET R R/min
gr P/LEP M/LEP G/LEP PER/M TPI P/LEP PP PER P/LEP
fl rpm m/min y/min t/m tpi rpm OW T rpm
cn * m/min y/min T/m tpi * * * *
Programming
34 G3305e4 09.2001 - en