Rigby copper2013 b

24
THE USE OF ALUMINA-CHROME REFRACTORIES IN THE HIGH WEAR AREAS OF ANODE REFINING VESSELS A. J. Rigby Harbison Walker Refractories, Cherrington Corporate Center, 400 Fairway Drive Moon Township, Pittsburgh, PA U.S.A.

description

 

Transcript of Rigby copper2013 b

Page 1: Rigby  copper2013 b

THE USE OF ALUMINA-CHROME REFRACTORIES IN THE HIGH WEAR

AREAS OF ANODE REFINING VESSELS 

A. J. Rigby 

Harbison Walker Refractories, Cherrington Corporate Center,

400 Fairway DriveMoon Township, Pittsburgh, PA U.S.A.

Page 2: Rigby  copper2013 b
Page 3: Rigby  copper2013 b
Page 4: Rigby  copper2013 b
Page 5: Rigby  copper2013 b

10mm.

DIRECT BONDED MAGNESIA-CHROME

Page 6: Rigby  copper2013 b

10mm.

REBONDED FUSED MAGNESIA-CHROME

Page 7: Rigby  copper2013 b

REBONDED FUSED GRAIN CONVERTER TUYERE BRICK

Page 8: Rigby  copper2013 b

MAGNESIA-CHROME BRICK FROM AN ANODE REFINING VESSEL

Page 9: Rigby  copper2013 b
Page 10: Rigby  copper2013 b

ALUMINA-CHROMIA REFRACTORY• AREAS OF SEVERE WEAR IN CONVERTER AND

ANODE VESSELS GENERALLY DUE TO PENETRATION AND SPALLING OF ALTERED BRICK

• IMPROVEMENTS IN REFRACTORY LIFE WILL BE DICTATED BY REDUCING OR ELIMINATING THIS PENETRATION

• LABORATORY TESTING CANNOT REPLICATE THESE WEAR MECHANISMS

Page 11: Rigby  copper2013 b

ANODE REFINING VESSEL REFRACTORY ISSUES

• WEAR AREAS AT THE TUYERES, SKIMMING MOUTH AND TAPHOLE

• TYPICALLY NEED MAINTENANCE EVERY 3-4 MONTHS

• SPECIFICALLY FOR THREE VESSELS DOWNTIME TO REPAIR REQUIRES 8-9 WEEKS OF LOST PRODUCTION (IF THERE IS NO SPARE VESSEL)

Page 12: Rigby  copper2013 b
Page 13: Rigby  copper2013 b
Page 14: Rigby  copper2013 b

ALUMINA-CHROME CASTABLE CONTAINING 30% Cr2O3 WITHCuO AT 1400oC FOR 5 HOURS

Page 15: Rigby  copper2013 b

ALUMINA-CHROME CASTABLE CONTAINING 30% Cr2O3

Page 16: Rigby  copper2013 b
Page 17: Rigby  copper2013 b
Page 18: Rigby  copper2013 b
Page 19: Rigby  copper2013 b
Page 20: Rigby  copper2013 b
Page 21: Rigby  copper2013 b

ANODE MOUTH OVERLAY

Page 22: Rigby  copper2013 b
Page 23: Rigby  copper2013 b

REPLACEMENT OF REBONDED FUSED GRAIN MAGNESIA-CHROME BRICK BY ALUMINA-CHROME GAVE UP TO 250% PERFORMANCE INCREASE

INCREASED PRODUCTION IN THE PLANT OF ~16,000MT OF ANODE COPPER

EVIDENCE THAT HIGHER CHROMIC OXIDE LININGWILL FURTHER IMPROVE LINING LIFE

NO EVIDENCE OF ANY INCREASE DEVELOPMENTOF SOLUBLE CHROME DURING USE IN COMPARISON TO MAGNESIA-CHROME

Page 24: Rigby  copper2013 b

CONCLUSIONS

MOST SEVERE AREAS OF WEAR IN ANODE REFININGVESSELS WILL BENEFIT BY 2-2.5 TIMES IMPROVEMENTUSING ALUMINA-CHROME REFRACTORY

REDUCED DOWNTIME CAN ALLOW FOR SIGNIFICANTPRODUCTION INCREASE

ALUMINA-CHROME NOW IN USE IN SLAGLINE OF SECONDARY RECYCLING FURNACES AND SHAFTSPENT ANODE REMELTING FURNACES.