Rich Stummer Daman Superior LLC UltraTech UV...
Transcript of Rich Stummer Daman Superior LLC UltraTech UV...
![Page 1: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/1.jpg)
Rich StummerDaman Superior LLC
UltraTech UV Systems
![Page 2: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/2.jpg)
UV Topics History of UV Types of UV Systems How does UV Disinfect Wastewater UV vs Other Disinfectant Systems Components of UV Systems Advantages & Disadvantages Design Considerations Maintenance of Systems
![Page 3: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/3.jpg)
History of UV in 1878 discovered that sunlight kills microbes in
broth. In 1904, the first quartz lamp was developed In 1910, the first UV system used to disinfect drinking
water 1938 Westinghouse Electric introduced the fluorescent
gas discharge tube 1940’s lamps and ballasts improved Late 1970’s, US EPA discouraged use of chlorine
![Page 4: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/4.jpg)
History of UV (continued)• Late 1970’s, US EPA started funding research and
grants for UV systems• 1978, full scale UV system for wastewater successfully
demonstrated at NW Bergen WWTP (Waldwick, NJ)• 1982, modular UV system for open channel to disinfect
wastewater introduced (gravity fed system with lamps parallel to flow (horizontal)
• Use of UV for wastewater growing since 1982
![Page 5: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/5.jpg)
![Page 6: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/6.jpg)
A survey in 2003 by the WaterEnvironment Federation showedthat of all the respondents , 24%used UV disinfection in theirwastewater treatment plants and66 % were planning to switch toUV (Water EnvironmentFederation 2004)
![Page 7: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/7.jpg)
UV Systems – Early Designs Problems with early systems
Replacement of bulbs, sleeves & ballasts required shut down of system
Poor cleaning systems Poor/inadequate hydraulics – short circuiting Improper cooling of ballasts – failures Ballasts & lamps not matched – lamp failures Difficulties in maintenance Lack of scientific knowledge to properly size UV systems
for wastewater
![Page 8: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/8.jpg)
UV Patents 1972, A. Landry issued patent for water flow through
teflon tube, UV lamps surrounded tube 1978, S. Ellner issued patent using rectangular, gravity
flow chamber with lamps perpendicular to flow with in-place chemical cleaning and UV sensors (installed in Suffern WWTP, Suffern, NY – still in use toady)
Numerous patents since on design and features for UV systems
![Page 9: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/9.jpg)
Types of UV Systems Closed Channel UV System
![Page 10: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/10.jpg)
Types of UV Systems Open Channel Vertical System
![Page 11: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/11.jpg)
![Page 12: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/12.jpg)
![Page 13: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/13.jpg)
![Page 14: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/14.jpg)
Sample Design – Vertical Modular System
60 “ Water Depth28 Lamp 16” or 20” Wide Modules40 Lamp 24” Wide ModulesHigh Output UV Lamps or Long Life
Standard Intensity LampsAir Scrub CleaningMechanical Wiper CleaningChemical Cleaning (optional)
![Page 15: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/15.jpg)
![Page 16: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/16.jpg)
![Page 17: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/17.jpg)
![Page 18: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/18.jpg)
![Page 19: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/19.jpg)
How Does UV Disinfect? UV light part of electromagnetic spectrum Radiation with wavelengths between 30 and 400
nanometers (nm) Shorter wavelengths than visible light Sometimes referred to as “black light” – can not be
seen by human eye UV spectrum divided into 3 parts
UV-A (315 – 400 nm) UV-B (280 – 315 nm) UV-C (200 – 280 nm) (UV output 254nm)
![Page 20: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/20.jpg)
How Does UV Disinfect Transfer of electromagnetic energy from mercury arc
lamp to organisms genetic material (DNA and RNA) UV penetrates cell wall and destroys cell ability to
reproduce Organisms can’t reproduce and eventually die off
![Page 21: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/21.jpg)
![Page 22: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/22.jpg)
![Page 23: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/23.jpg)
How Does UV Disinfect Wavelengths of UV
UV-A 315 – 400 nm UV- B 280 – 315 nm UV - C 200 – 280 nm
Optimum wavelength to effectively inactivate microorganisms is range of 250 – 270 nm (UV – C)
![Page 24: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/24.jpg)
Methods of Disinfection Chlorination – different forms
Chlorine gas Chlorine dioxide Sodium Hypochlorite Calcium Hypochlorite
Ozone – Gas Ultraviolet Light – UV Radiation
![Page 25: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/25.jpg)
Chlorination Special handling and storage requirements De-chlorination required Low equipment costs Corrosive Toxic Formation of carcinogenic by-products
(trihalomethanes) Requires chemical feed system Effectiveness depends on water quality
![Page 26: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/26.jpg)
Ozone Strong oxidizer, non-selective Highest equipment costs Short life span but still requires neutralization Corrosive Toxic Requires feed gas and injection system Effectiveness depends on water quality High output systems require ozone off gas destruction
![Page 27: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/27.jpg)
Ultraviolet No special handling No post treatment Moderate equipment costs Frequent preventative maintenance cycles Fouling can reduce effectiveness Performance dependant on water quality
![Page 28: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/28.jpg)
![Page 29: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/29.jpg)
![Page 30: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/30.jpg)
Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps
Wavelength of 253.7 nm Lengths of 0.75 and 1.5 meters with diameter of 1.5 – 2.0 cm.
Medium-Pressure Lamps 15-20 times germicidal UV intensity of low-pressure lamps Disinfect faster Greater penetration capacity Operate at higher temperatures; higher energy consumption
![Page 31: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/31.jpg)
Components of UV System Mercury Arc Lamps – pressure refers to pressure inside
lamps; intensity refers to energy output Low-pressure Low-intensity (lp-li) Low-pressure High-intensity (lp-hi) Medium-pressure High-intensity (mp-hi)
Reactor Ballasts
![Page 32: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/32.jpg)
Low-Pressure Low-Intensity Lamps Most energy efficient for UV disinfection Operating temperature is 40 – 60 degrees Celsius Lamps contain mercury vapor and argon gas Emits nearly monochromatic radiation About 85% of emissions are at 253.7nm – peak
germicidal effectiveness Emit approximately 0.2 germicidal watts per
centimeter arc length (W/cm)
![Page 33: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/33.jpg)
Low-pressure High intensity Operating temperature of 180 – 200 degrees celsius Emits broader, polychromatic radiation therefore less
efficient than lp-li High-intensity = higher capacity : requires fewer lamps Germicidal output 13 W/cm Lamp costs 3+ times cost of lp-li
![Page 34: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/34.jpg)
High-pressure High intensity Operating temperature of 600 – 800 degrees celcius Emits broader, polychromatic radiation therefore less
efficient than lp-li High-intensity = higher capacity : requires fewer lamps Germicidal output 16 W/cm Lamp costs 5 times cost of lp-li Power costs about 4 times higher than lp-hi
![Page 35: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/35.jpg)
High-intensity or Low-intensity Low-intensity best suited for smaller systems High-intensity best suited for larger systems Example : Southtowns WWTP 16 MGD The lp-li system is not considered cost effective at the
large flow rates experienced at the Southtowns WWTP because of the number of lamps required. The lp-lialternatives would require approximately 2,160 lamps, while the lp-hi system would need 360 lamps (6 times less) and the mp-hi alternative would need 176 lamps (12 times less).
![Page 36: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/36.jpg)
![Page 37: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/37.jpg)
Horizontal UV System Utilized when channel depth too shallow for vertical
system Electrical connections under water Disinfecting area limited to arc length of UV lamp Rack must be removed from channel and underwater
seal disassembled to change UV lamp Lamp change takes 10 minutes
![Page 38: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/38.jpg)
Vertical UV System Requires channel depth of at least 60” All electrical connections above water Flow perpendicular – area of UV energy expanded Lamps changed without removing module from
channel Lamp change takes 15 seconds
![Page 39: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/39.jpg)
Example UV System with 300 lamps Horizontal system would take 50 hours of labor to
change lamps Vertical system would take 1 hour and 25 minutes to
change lamps
![Page 40: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/40.jpg)
UV Dosage Comparison UV Dosage is a function of the UV Intensity times
the Contact Time Engineer should require suppliers to provide
UV output of specific lamp Number of UV lamps Contact time at maximum flow rate
(# of UV lamps) x (UV output) = Total UV watts in system
(Total UV watts) x (contact time) = UV Watt Seconds
![Page 41: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/41.jpg)
EXAMPLE Mfg X proposes 98 UV lamps Output of 65 watts (at 254nm) Contact time of 12 seconds 98 x 65 =6,370 6,370 x 12 = 76,440 This system rates at 76,440 watt seconds Contact Time is cheaper than Intensity Since no harm in over dosing, design of 2-3 times
minimum dose is common
![Page 42: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/42.jpg)
Understanding UV Disinfection Terms
Ultraviolet Dose Collimated Beam Test UV Lamp Life UV Lamp Description UV Lamp Comparisons
![Page 43: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/43.jpg)
Ultraviolet Dose UV Dose = Intensity x Time expressed in
uWattseconds/cm2, Mwattseconds/cm2 or Jewels Problem – UV Transmittance of effluent impact on
true UV dose; “average” UV intensity; “average” contact time; hydraulics
Solution – Bioassay – performance based validation (Delivered Dose is actual dose received by targeted organism)
![Page 44: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/44.jpg)
Collimated Beam Test Test conducted with MS2 phage in solutions of
effluent will indicate the additional contact time to achieve specific levels of disinfection
Does not provide information relating to actual UV dose
![Page 45: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/45.jpg)
UV Lamp Life UV lamps will continue to provide the same amount of
visible light after the germicidal output has diminished below safe disinfecting levels (solarization of the lamp glass)
Effective Lamp Life – where UV output has diminished to 70% of the new lamp output after 100 hours of operation
Lamp Life is not the number of hours of operation until the lamp goes out
![Page 46: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/46.jpg)
UV Lamp Life (cont.) Lamp Manufacturer Certification for operating hours
possible before UV output drops to 70% of new lamp after 100 hours of operation
Specify intensity @254nm since polychromatic medium pressure UV lamps have different operating hours for specific wave lengths
Drop off in UV intensity @254nm is quicker than other wavelengths produced by polychromatic medium pressure lamps
![Page 47: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/47.jpg)
UV Lamp Descriptions “Low Pressure Lamp”
Monochromatic UV Output primarily 254nm 30-40% of input energy converted to UV @254nm Available in lengths 8”-64”, 8 watts to 300 watts
“Medium Pressure Lamp” Polychromatic UV 200nm to 700nm, higher pressure &
temps than Low Pressure Lamps 5-7% of input energy converted to UV@254nm
![Page 48: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/48.jpg)
UV Lamp Descriptions (cont.) Parameters for describing UV Lamps
Lamp Grouping – Medium or Low Pressure Lamp Length Lamp Diameter Electrical input UV output @ 254mm Manufacturer’s lamp life certification Source of Lamps (proprietary?) Size of quartz jacket Wall thickness of quartz jacket
![Page 49: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/49.jpg)
UV Lamp Descriptions (cont.) Eliminate Misleading Data
“It is possible to inactivate cryptosporidium with medium pressure UV but not with low pressure UV.” UV dose is UV dose regardless of lamp used.
“One medium pressure lamp will replace 6 low pressure lamps.” What is electrical input and UV output @254nm, what is lamp length, diameter, etc.
You could claim 1 fluorescent lamp could replace 300 incandescent lamps if we compare an 8’ fluorescent lamp with a .5 watt flashlight incandescent lamp
![Page 50: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/50.jpg)
UV Lamp Comparisons Industry Standard in G64T5 low pressure lamp
58” arc length 5/8” diameter 65 watt electrical input 26.5 UV output @ 254nm Effective lamp life – 10,000 hours
Manufacturer “X” claims his lamp will replace 10 standard UV lamps Require Manufacturer “X” to set up pilot demonstrating
claim – compare actual results
![Page 51: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/51.jpg)
Conclusions UV dose should only refer to actual dose determined
by Biassay UV dose should only be expressed in uWatt
seconds/cm2 Bioassay protocol employ universal standards
MS2 phage Buffered sterile distilled water titer 1 cm depth in petri dish Phage concentrations of 1,000,000/ml Minimum 3 flow rates & 3 separate runs for each
![Page 52: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/52.jpg)
Conclusions (cont.) Effective Lamp Life - # of hours of operation until lamp
output @ 254nm drops to 70% of output of new lamp after 100 hours operation
UV Lamp Description to include Lamp grouping Lamp dimensions Electrical input UV output at 254nm only Manufacturers who produce lamp Dimensions of quartz jacket – diameter & wall thickness Claims to UV Lamp reductions based on side by side test
![Page 53: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/53.jpg)
Source of Information Let’s Take the Mystery Out of UV Design
Abstract published by WEF Author – Sidney Ellner, Technical Director for UltraTech
Systems, Inc.
![Page 54: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/54.jpg)
Reactors Contact Reactor –Lamps with quartz sleeve, placed in
wastewater stream Parallel or Perpendicular to flow Flap gates or Weirs control wastewater flow Ballast provides starting voltage and maintains continuous
current
Non-Contact Reactor – Lamps suspended outside transparent conduit Conduit carries wastewater to be disinfected Ballast provides starting voltage and maintains continuous
current
![Page 55: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/55.jpg)
Contact Reactors
![Page 56: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/56.jpg)
Ballasts Ballasts must be compatible with lamps Should be ventilated
Over heating shortens life of ballast Over heating can cause fire
![Page 57: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/57.jpg)
Life Cycle of Components Lamps – average life of 8,760 to 14,000 hours
Cycling on/off reduces efficacy of lamp Usually replaced after 12,000 hours
Ballast – average life 10 to 15 years Usually replaced after 10 years
Quartz Sleeves – average life 5 to 8 years Usually replaced every 5 years
![Page 58: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/58.jpg)
Advantages of UV Effective at inactivating most viruses, spores and cysts Physical process rather than chemical – not handling
or storing hazardous/corrosive chemicals No residual effect User friendly for operators Shorter contact time (20 – 30 seconds for lp-li) Smaller footprint for equipment
![Page 59: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/59.jpg)
Disadvantages Low dosage may not inactivate some viruses, spores
and cycts Organisms can sometimes repair and reactivate -
Photoreactivation Preventative maintenance program necessary to
control fouling of tubes Turbidy and Total Suspended Solids (TSS) can render
UV disinfection ineffective UV disinfection not as cost effective as chlorination
until dechlorination and costs of meeting fire codes included
![Page 60: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/60.jpg)
Transmittance UV transmittance represents the percentage of UV
energy in the water that reaches the microorganisms. The lower the transmittance, the lower the amount of UV light that reaches the microorganism. UV transmission is dependent on the spacing of lamps and the water quality of the liquid. The water quality characteristics that affect transmittance include iron, hardness, suspended solids, humic materials and organic dyes.
![Page 61: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/61.jpg)
Photoreactivation, Nucleotide Excision Repair (NER) and Recombination Repair Cell’s ability to repair damage from UV once light is
removed All mechanisms performed by enzymes – affected by
temperature, pH and ionic strength
![Page 62: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/62.jpg)
Design Characteristics Flow Rate Reactor Design Suspended and Colloidal Solids (microscopic solids
suspended in liquid – milk) Initial Bacteria Density Footprint of Equipment
![Page 63: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/63.jpg)
Reactor Design Channel design
Short circuiting, dead zones UV dose required
Suspended and colloidal solids Bacterial density
Flow – prevent “short circuiting” Prevent particle “shading” Eliminate “dead zones”
Ensure proper contact time Lamp fouling, scaling
![Page 64: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/64.jpg)
Design Considerations Plug Flow – flow is in one direction with little or no
mixing or turblence. Reynolds Number – high number = turbulent flow;
low number = smooth flow Turbulent flow is desired (Reynold’s Number above
5,000) – reduces occurrance of “particle shading”
![Page 65: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/65.jpg)
Operation and Maintenance UV Light Process Training Highlights Recommended Typical Maintenance Activity for UV
Processes Process Checks Electrical Checks Michanical Checks
![Page 66: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/66.jpg)
UV Light Process Training Highlights Design Flows and Characteristics Alarm Systems Mechanical Checks Electrical Checks Control Logic for Programmable Logic Controller Replacement of Basic Components
![Page 67: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/67.jpg)
Recommended Typical Maintenance Activities for UV Processes Check on-line UV transmittance analyzer calibration
(weekly) Cheek sleeves and wipers for leaks (monthly) UV intensity calibration check (monthly) Check cleaning efficiency (monthly) Check cleaning fluid reservoir (semiannually) Test-trip ground fault interrupt breakers (annually)
![Page 68: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/68.jpg)
Recommended Typical Maintenance Activities for UV Processes Replace lamps (mfg recommendation) Check flowmeter calibration (mfg recommendation) Properly dispose of lamps (when changed) Properly dispose of quartz sleeves (when changed) Clean and calibrate transmittance monitor (mfg
recommendations)
![Page 69: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/69.jpg)
Process Checks Effluent Transmittance Effluent total suspended solids concentration Ultraviolet spectra Effluent color Industrial dischargers Algae Iron/manganese/hardness Microbial testing procedures
![Page 70: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/70.jpg)
Electrical Checks Lamps are energized Lamps are connected Useful lamp life Ballast output
![Page 71: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/71.jpg)
Mechanical Checks Cleaning system to ensure acceptable performance Proper delivery of chemical On-line transmittance measurements On-line intensity measurements Flowmeter calibration Ballasts closed loop-cooing system
![Page 72: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/72.jpg)
Altoona Water AuthorityWastewater Division Chlorine System – 1991
Stored chlorine onsite – 2,000# canisters 80-150# added daily to chlorine tank Effluent with residual chlorine threatened aquatic life Exposure risk for employees – several times workers
forced to wear protective breathing equipment due to toxic leaks
![Page 73: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/73.jpg)
Altoona Water AuthorityWastewater Division UV System Installed in December 1991 – Ultraviolet
Purification Systems 2 horizontal stainless steel reactors installed Each reactor contains 348 UV lamps, 2 banks 1 reactor handles flows of 10 MGD Alarm activated if lamp burns out or intensity drops
below effective range UV unit can be remotely operated
![Page 74: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/74.jpg)
Altoona Water AuthorityWastewater Division Results
Environmentally responsible, convenient and cost effective solution for disinfecting wastewater discharge
Performance equal to chlorine Effluent meets NPDES permit requirements Local aquatic life protected Reduced worker exposure to chlorine gas
![Page 75: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/75.jpg)
Altoona Water AuthorityWastewater Division Advantages
Safety – no hazardous chemicals Simplified compliance - easier compliance with NPDES
permit requirements and Fire Code regulations Reduced Effluent Toxicity – no residue discharged Maintenance & Cleaning – lamp jackets cleaned twice a
month; jackets cleaned 3 times a year; lamps replaced after 7,500 hours use
Reliability – in-place cleaning, system detects decreased UV intensity
![Page 76: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/76.jpg)
Acknowledgments The History of UV and Wastewater by G. Elliott
Whitby1,2 and O. Karl Scheible3
Evaluation of Ultraviolet (UV) Radiation Disinfection Technologies for Wastewater Treatment Plant Effluent by New York State Energy Research and Development
Evaluation of Disinfection Units for Onsite Wastewater Treatment Systems by Center for Environmental and Water Resources Engineering
![Page 77: Rich Stummer Daman Superior LLC UltraTech UV Systemsnesowea.org/wp-content/uploads/2015/08/02a-Stummer... · Low-Pressure vs Medium Pressure Lamps Low-Pressure Lamps Wavelength of](https://reader030.fdocuments.in/reader030/viewer/2022040309/5f2b329b78e18374cb111743/html5/thumbnails/77.jpg)
Acknowledgments (cont.) Wastewater Technology Fact Sheet Ultraviolet
Disinfection by US EPA 832-F-99-064 Ultraviolet Disinfection by US EPA WWFS0M20 Abstract – Let’s Take the Mystery Out of UV Design by
Sidney Ellner, Technical Director UltraTech Systems, Inc.