RIA14 - RIA16

5
Products Solutions Services Application / Function Overview Technical data Dimensions Electrical connection Price table Contact Go to shop Technical Datasheet TD 00062E/24/EN/01.13 5-digit LC display One limit value ATEX approvals Illuminated display Bargraph and units Complete product information: www.e-direct.us/ria14_16 Specs at a glance: Line voltage drop: < 4 V at 3 to 22 mA Display: 5-digit LC display Degree of protection: IP 67, NEMA 4X Maximum measured error: < 0.1 % of scaled display range Loop-powered field indicator RIA14 / RIA16 $ 342.00 RIA16 RIA15

Transcript of RIA14 - RIA16

Products Solutions Services

Application / FunctionOverview Technical data Dimensions

Electrical connection Price table ContactGo to shop

Technical DatasheetTD 00062E/24/EN/01.13

• 5-digit LC display•One limit value•ATEX approvals• Illuminated display• Bargraph and units

Complete product information:www.e-direct.us/ria14_16

Specs at a glance:

•Line voltage drop: < 4 V at 3 to 22 mA

•Display: 5-digit LC display•Degree of protection:

IP 67, NEMA 4X•Maximum measured error:

< 0.1 % of scaled display range

Loop-powered field indicator

RIA14/RIA16

$ 342.00RIA16

RIA15

RIA14/RIA16 2

Overview Technical data Dimensions

Electrical connection Price table ContactGo to shop

Application / Function

Application The RIA14/RIA16 field indicators monitor measurement signals and display them with high resolution and accuracy. The indicators feature one Open Collector output for monitoring a limit value. They permit universal installation and are particularly suitable for use in the field or in mobile rigs.

Function The indicator records an analog measuring signal and shows this on the display. The LC display shows the current measured value digitally and as a bargraph with limit value violation signalling. The indicator is looped into the 4 to 20 mA circuit and obtains the required energy from there.

Applicationexample

EX

Transmitter4…20 mA

Transmitter4…20 mA

EXNon-hazardous areaExplosive hazardous area

Zone 1,2Zone 21, 22

Power supply

Power supply

RIA14/RIA16 3

Application / FunctionOverview

Electrical connection Price table ContactGo to shop

DimensionsTechnical data

Technicaldata Dimensions(ininches)

InputMeasuring range 4 to 20 mA (reverse polarity protection)Line voltage drop < 4 V at 3 to 22 mAMax. line voltage drop < 6 V at max. short-circuit current 200 mA

OutputOutput Digital limit switch Passive, open collector:

Imax = 200 mA, Umax= 35 V, Ulow/max = < 2 V at 200 mA Max. reaction time to limit value = 250 ms

Signal on alarm No measured value visible on the LC display, no background illumination; open collector inactive

Performance characteristicsReference operating conditions

T= 25 °C (77 °F)

Max. measured error < 0.1% of scaled display rangeInfluence of ambient temperature

Effect on the accuracy when ambient temperature changes by 1 K: 0.01%

Operating conditionsMounting location Wall or pipe mountingAmbient temp. limits -40 to +80 °C (-40 to +176 °F ) (at < -20 °C

(< -4 °F) the display can react slowly; at < -30 °C (-22 °F) readability of the display cannot be guaranteed)

Storage temperature -40 to +80 °C (-40 to +176 °F)Electrical safety As per IEC 61010-1, UL61010-1, CSA C22.2

No. 1010.1-92Climate class As per IEC 60654-1, Class CEMC As per EN 61326 (IEC 61326) and NAMUR

(NE21)Degree of protection IP 67, NEMA 4X

Mechanical constructionMaterial RIA14: housing: die-cast aluminum AlSi10Mg

with powder coating on polyester basis; optional: Stainless steel 1.4435 (AISI 316L)RIA16: housing: Fiber-glass reinforced plastic PBT-GF30; optional: Aluminum AlSi12

Weight RIA14: aluminium housing: approx. 1.6 kg (3.53 lbs) stainless steel housing: approx. 4.2 kg (9.26 lbs)RIA16: plastic housing: approx. 500 g (1.1 lbs) aluminum housing: approx. 1.7 kg (3.75 lbs)

Terminals Cables/wires up to max. 2.5 mm² (14 AWG) plus ferrule

Human interfaceDisplay range -19999 to +99999Offset -19999 to +99999Character height RIA14: 20.5 mm (0.81”)

RIA16: 26 mm (1.02”)Signalling Measuring range overshoot/undershootOperating elements 3-key operation (-/+/E) integrated in device,

access with housing openRemote operation The device is configured with the FieldCare

PC operating software

ApprovalsEx approval ATEX II2(1)G Ex ib[ia] IIC T6/T5/T4Ex approval (RIA14) ATEX II2G Ex d IIC T6/T5/T4; ATEX II2D

6.54.4 4.2

5.3

5.2

Installation according to instruction manual

RIA14

7.83

3.78

5.24

6.22

Installation according to instruction manual

RIA16

RIA14/RIA16 4

Application / FunctionOverview Technical data Dimensions

ContactGo to shopElectrical connection Price table

Pricetable

Process indicator RIA14 Order no. Price/pcs. in USDHousing Approval 1 to 5 6 to 10 11 to 35Field, alu die cast Non-hazardous area RIA14-AA3C 535.00 498.00 471.00

RIA14-AA3C+I4 591.00 550.00 520.00ATEX II2(1)G Ex ib[ia] IIC T6 RIA14-BA3C 603.00 561.00 531.00

RIA14-BA3C+I4 659.00 613.00 580.00ATEX II2G Ex d IIC T6 RIA14-BD3C 671.00 624.00 590.00

RIA14-BD3C+I4 727.00 676.00 640.00ATEX II2D RIA14-BF3C 671.00 624.00 590.00

RIA14-BF3C+I4 727.00 676.00 640.00

Field indicator RIA16 Order no. Price/pcs. in USD

Housing Approval 1 to 5 6 to 10 11 to 35Plastics, glass fiber reinforced

Non-hazardous area RIA16-AA1A+E1 389.00 362.00 342.00Mounting kit wall/tube RIA16-AA1A+E1I2 445.00 414.00 392.00

Alu Non-hazardous area RIA16-AA2A+E1 499.00 464.00 439.00Mounting kit wall/tube RIA16-AA2A+E1I2 555.00 516.00 488.00ATEX II2(1)G Ex ib[ia] IIC T6 RIA16-BA2A+E1 567.00 527.00 499.00Mounting kit wall/tube RIA16-BA2A+E1I2 623.00 579.00 548.00

Accessories Order no. Price/pcs. in USDMounting set wall+pipe (W08) 71089844 74.00Configuration kit TXU10-for PC-programmable devices. set-up programme+interface cable for PC with USB-Port. 4 pin plug

TXU10-AC 204.00

Prices valid until 09.30.2013 in U.S. dollars per unit (not including shipping and applicable sales tax).See Endress+Hauser, Inc. Terms and Conditions of Sale for shipping, tax, and payment terms.

Complete product information:www.e-direct.us/ria14_16

Moreproductstocompleteyourmeasuringpoint…

+

+

+

– +

++1

+–

23

122

33

2

3

passive

active

RIA14

Y

I

Y

I

Terminal 2 and 3Open Collector

loop power supply

Terminal 2 and 3Open Collector

Electricalconnection

YY

23

II

+ –

+ –– +++

+ – 1a 1b

passive passiveactive

RIA16

YI

–+ +

+ – 1a 1b

Terminal 2 and 3Open Collector

1*) 1*)

1*) Loop power supply

Pressuretransmitter Cerabar T PMC131

ProcesstransmitterRMA42

PointlevelswitchLiquiphant T FTL20

Application / FunctionOverview Technical data Dimensions

Electrical connection Price table ContactGo to shop

Contact

E-directEndress+Hauser, Inc.2350 Endress PlaceGreenwood, IN 46143

Direct order

Internet www.e-direct.usby phone 888- EH-DIRECT

(343-4732)per Fax 317-535-8498E-Mail [email protected]