RHIC Magnet Control and PLL System Specifications

23
6/10/02 RHIC Magnet Control and PLL System Specifications Carl Schultheiss Cern PLL Workshop June 10-11, 2002

description

RHIC Magnet Control and PLL System Specifications. Carl Schultheiss Cern PLL Workshop June 10-11, 2002. MAGNET CONTROL SYSTEM. Main Quad Bus. MAGNET CONTROL SYSTEM. Quads at IRs 2,6,8, and 12 o’clock. MAGNET CONTROL SYSTEM. Waveform Generator Interconnections. FEC. Waveform Generator. - PowerPoint PPT Presentation

Transcript of RHIC Magnet Control and PLL System Specifications

Page 1: RHIC Magnet Control and PLL System Specifications

6/10/02

RHIC Magnet Control and PLL System Specifications

Carl Schultheiss

Cern PLL Workshop

June 10-11, 2002

Page 2: RHIC Magnet Control and PLL System Specifications

6/10/02

MAGNET CONTROL SYSTEM

Main Quad Bus

Page 3: RHIC Magnet Control and PLL System Specifications

6/10/02

MAGNET CONTROL SYSTEM

Quads at IRs 2,6,8, and 12 o’clock

Page 4: RHIC Magnet Control and PLL System Specifications

6/10/02

MAGNET CONTROL SYSTEM

WaveformGenerator

Ethernet

RTDL

EventLink

Serial link to PS

Serial link to PS

Waveform Generator Interconnections

FEC

Page 5: RHIC Magnet Control and PLL System Specifications

6/10/02

MAGNET CONTROL SYSTEM

Description of strengths for real-time tune feedback.

• Tables of strength versus B for the magnets are calculated by building a ramp using the off-line model. These tables are downloaded to the waveform generators before each ramp.

Page 6: RHIC Magnet Control and PLL System Specifications

6/10/02

MAGNET CONTROL SYSTEM

• The present B is broadcast on the Real Time Data Link (RTDL) to the waveform generators. The waveform generators use the present B to calculate the strength for each magnet.

Page 7: RHIC Magnet Control and PLL System Specifications

6/10/02

MAGNET CONTROL SYSTEM

• Transfer tables of magnet current versus magnet field are also downloaded to the waveform generators. Cubic spline interpolation is used to calculate the required current given the strength for each magnet.

Page 8: RHIC Magnet Control and PLL System Specifications

6/10/02

MAGNET CONTROL SYSTEM

• The quad magnets in the Interaction Regions (IRs) are in the main quad circuit. Their current is individually adjusted by shunting some of the main quad current around them. This is done by nested power supplies.

Page 9: RHIC Magnet Control and PLL System Specifications

6/10/02

MAGNET CONTROL SYSTEM

• The waveform generators subtract the main quad current, and if necessary the trim quad current, from the calculated current. These quad currents are broadcast on the RTDL.

Page 10: RHIC Magnet Control and PLL System Specifications

6/10/02

MAGNET CONTROL SYSTEM

• This current is sent to the power supply interface card. This card has two inputs; the second input is used to send the current of the “previous” waveform generator. This current is subtracted from the total calculated current and the result is sent to the power supply.

Page 11: RHIC Magnet Control and PLL System Specifications

6/10/02

MAGNET CONTROL SYSTEM

• The RTDL also broadcasts delta strengths, in real-time, for the Main Quads and the Sextupoles. This delta strength is added to the strengths from the tables. This adjusts the main quad currents to control the tunes.

Page 12: RHIC Magnet Control and PLL System Specifications

6/10/02

MAGNET CONTROL SYSTEM

• The IR waveform generators subtract the main quad currents from their magnet currents, this compensates the changing main quad currents and the IRs are not disturbed.

• The sextupoles can be controlled by a similar process to adjust the chromaticity.

Page 13: RHIC Magnet Control and PLL System Specifications

6/10/02

PLL SYSTEM SPECIFICATIONS

• Specify the damping factor = 0.7. This is a good compromise in most applications, it provides fast response, small overshoot, and minimum noise bandwidth BL.

Page 14: RHIC Magnet Control and PLL System Specifications

6/10/02

PLL SYSTEM SPECIFICATIONS

• Specify the loop noise bandwidth BL. For stable operation a SNRL should be equal to or greater than 4 (6 dB). Assume a bandpass prefilter with a bandwidth of 500 Hz. and a SNRi of 1 (0 dB) From:

L

iiL B

BSNRSNR

2

the loop noise bandwidth BL is 62.5 Hz.

Page 15: RHIC Magnet Control and PLL System Specifications

6/10/02

PLL SYSTEM SPECIFICATIONS

• The natural frequency of the loop n based on the loop bandwidth and the damping factor is calculated from:

and is 897.6 rad/sec. or 142.9 Hz.

4

1

2n

LB

Page 16: RHIC Magnet Control and PLL System Specifications

6/10/02

PLL SYSTEM SPECIFICATIONS

• The minimum natural frequency n based on the maximum rate of change of the tune is found from:

Assuming a maximum tune rate of change of 0.05 /sec. at a revolution frequency of 77.805 kHz. gives a frequency rate of change of 24443 rad/sec2 The natural frequency must be larger than 221 rad/sec or 35 Hz.

2

2n

Page 17: RHIC Magnet Control and PLL System Specifications

6/10/02

PLL SYSTEM SPECIFICATIONS

• The two calculations indicate n should be between 35 Hz and 143 Hz. Choose 50 Hz.

• In a digital system the sample rate at the compensation filter should be at least 5 times the required bandwidth. This gives a final sample rate of about 250 Hz.

Page 18: RHIC Magnet Control and PLL System Specifications

6/10/02

PLL SYSTEM SPECIFICATIONS

• The damping factor = 0.7• The natural frequency n = 50 Hz• The loop noise bandwidth BL = 26.4 Hz• Compensation Filter Sample Rate = 250Hz• SNRL / SNRi = 18.94 = 25 dB.

PLL SYSTEM SPECIFICATIONS SUMMARY

Page 19: RHIC Magnet Control and PLL System Specifications

6/10/02

Qloop Simulation Block Diagram

Page 20: RHIC Magnet Control and PLL System Specifications

6/10/02

Qloop Simulation

Page 21: RHIC Magnet Control and PLL System Specifications

6/10/02

Measured Qloop Results

Page 22: RHIC Magnet Control and PLL System Specifications

6/10/02

Open Loop Qloop Magnitude

173.492129

40.674467

M XOLR i

M YOLR i

362.020063 10

9 i

2

1 109

1 108

1 107

1 106

1 105

1 104

1 103

0.01 0.1 1 10 100

50

0

50

100

150

200System Open Loop Magnitude Response

Frequency (Hz)

Mag

nitu

de (

dB0

Page 23: RHIC Magnet Control and PLL System Specifications

6/10/02

Closed Loop Qloop Magnitude

0.450849

40.594853

M XCLR i

M YCLR i

362.020063 10

9 i

2

1 109

1 108

1 107

1 106

1 105

1 104

1 103

0.01 0.1 1 10 100

50

40

30

20

10

0

10System Closed Loop Magnitude Response

Frequency (Hz)

Mag

nitu

de (

dB)