FEATURES OF THE TRUE OAK CORRUGATED SERIES
• Smooth, rounded sinusoidal wave profile which can be seen from afar. • Strikingly different from the shallow v-shaped post 1930’s profile with no flat areas. • Continuous curves create an ever changing shadow and prison bar ‘aesthetics’. • Revives the original classic 1829 profile. • Superior strength & water carrying capacity. • 20 Year Material & Installation Guarantee when installed by a Revolution Roofing Licensed Contractor. • New semi metallic colour ‘Cordite Grey’ unique to Revolution Roofing.• Re-engineered superior profile optimising the use of steel.
For too many years architects, builders and roofers have had limited choices in roofing and material options.
Until now.
In an industry starved of innovation, Revolution Roofing has identified a new opportunity to bring a distinct character back to Australia’s roofscapes.
It’s time to roll out a bolder, character filled and more aesthetically pleasing roofing alternative to stimulate, captivate and invigorate the way the market thinks about steel roofing.
Introducing True Oak – a return to a rounder, fuller, more shapely and deeper profile in corrugated roofing popular before the turn of the century.
True Oak is a unique product range featuring more options, colours and more importantly, choices for anyone who specifies roofing.
Integrating form and function, the character and distinct shadowlines of the True Oak profiles are designed to help stimulate the imaginations of architects, builders, roofers and their customers.
The original deeper, residential grade corrugated profile was a 13/16 inch (21mm) rounded, snub nose design and strikingly different to the current 15.9mm V-shaped corrugated profile. It was a quality product used to create functional buildings and distinctive forms of appealing simplicity.
Now, thanks to Revolution Roofing, it’s back better than ever.
Corrugated iron has been around for over 180 years in Australia. Throughout this time, corro has gone from a choice of many varying profiles to a choice of just one.
Roofing and material choices and options for specifying architects have become increasingly limited in Australia, with only one 3 inch shallow corrugated offering being available since 1939. This unfortunate lack of development in new corrugated roofing over the past 70 years has led to a proliferation of featureless, lackluster roofing profiles.
With the revolutionary True Oak profiles, we have a product that allows roofing to once again become a major part of a residential building’s identity, style and charm.
By marrying the lessons of history with 21st Century technology, Revolution Roofing heralds a new era in roofing with its continuous, deep, fully rounded corrugated profile.
Not since 1829 has there been this much of a change to the Australian Roof Industry and we invite you to be among the first to take advantage of the superbly versatile True Oak series.
PLYMPTON PARK SA 576 Marion Road P: 08 8352 0990
2
TRUE OAK CORRUGATED SERIESREVSPEC
EXCLUSIVE FINISHES ONLY AVAILABLE WHEN USING TRUE OAK
MILE END SOUTH SA55 Scotland Road
P: 08 8352 0911 F: 08 8352 0922
REGENCY PARK SA5-17 Taminga Street
P: 08 8352 0911 F: 08 8352 0922
LONSDALE SA14 Bredbo Street
P: 08 8186 0545 F: 08 8186 1341
OSBORNE PARK WA55b Hector Street
P: 08 9217 9011 F: 08 9204 5564
HISTORIC NEW COLOUR FROM THE PAST Even BlueScope Steel is excited! To coincide with the launch of Revolution Roofings new True Oak corrugated profiles, BlueScope Steel have launched a new semi-metallic colour ‘Cordite Grey’ in the style of the original graphite micaceous paints.
MATTE FINISHTraditional Colorbond Steel is available in many different colours but has only been available in standard gloss or enhanced gloss for verandas. Revolution Roofing partnered with BlueScope Steel to develop the first Colorbond Matt Finish product for the Australian market. What started as adjusting the gloss levels of Colorbond Monument has turned in to one of the most exciting new finishes to hit the Australia market for years.
• Stock Colours:• Stealth™ (Monument)• Smoke™ (Windspray)• Desert Storm™ (Terrain)
Other colours are available on request but may be subject to longer lead times or minimum order quantities.
FENCINGIt has been many years since there has been a new colour in the fencing range so we thought to make up for lost time we would introduce 2. For all the home owners who want their fence to match their roofs we introduced double sided Seedpod (Dune) and Shadow (Monument) in our True Oak 21mm Deep profile. Also available are the good neighbour Colorbond post and rails to match the sheets.
DOUBLE SIDED VERANDA COLOURSOur range of Verandas, Carports and Patios - Victory - come in a range of double-sided COLORBOND® Steel sheets with a high gloss finish to give you a low maintenance, attractive and street-smart structure without the need for painting.
The great selection of COLORBOND® Steel roofing colours also allow for a choice of gloss on the underside of the sheeting to complement your home. There are 8 different options including Classic Cream, Monument, Woodland Grey, Paperbark, Manor Red, Mangrove, Gully and Surfmist.
As a company we will continue to push the boundaries, this often means bringing out new profiles or new finishes for existing products. Over the last 5 years we have listened to the customer demands for more choices and we are proud to offer the following finishes that are exclusive to Revolution Roofing and our exciting True Oak range:
PLYMPTON PARK SA 576 Marion Road P: 08 8352 0990
REVSPECTRUE OAK ‘M
ID 10m
m’
3
RR13.1
TRUE OAK CORRUGATED SERIESREVSPEC
TRUE OAK WATERTIGHTGUARANTEE
MILE END SOUTH SA55 Scotland Road
P: 08 8352 0911 F: 08 8352 0922
REGENCY PARK SA5-17 Taminga Street
P: 08 8352 0911 F: 08 8352 0922
LONSDALE SA14 Bredbo Street
P: 08 8186 0545 F: 08 8186 1341
OSBORNE PARK WA55b Hector Street
P: 08 9217 9011 F: 08 9204 5564
GUARANTEED TO LAST Revolution Roofing are so sure that their True Oak Corrugated will stand the test of time they are willing to back it up with an exclusive True Oak 20 Year Watertight Installation Guarantee. With the improved strength of the profile comes the improved warranty to match; the ‘industry standard’ of a 5 Year Watertight Guarantee for corrugated has been surpassed and then some.
Whether it is a school, a nursing home or your family home, you can have the comfort of knowing that the True Oak is the strongest corrugated profile in Australia and if it has been installed by a Revolution Roofing Approved Contractor it will not leak.
PLYMPTON PARK SA 576 Marion Road P: 08 8352 0990
REVSPECTRUE OAK ‘M
ID 10m
m’
4MILE END SOUTH SA
55 Scotland RoadP: 08 8352 0911 F: 08 8352 0922
REGENCY PARK SA5-17 Taminga Street
P: 08 8352 0911 F: 08 8352 0922
LONSDALE SA14 Bredbo Street
P: 08 8186 0545 F: 08 8186 1341
OSBORNE PARK WA55b Hector Street
P: 08 9217 9011 F: 08 9204 5564
This page has been intentionally left blank
PLYMPTON PARK SA 576 Marion Road P: 08 8352 0990
REVSPECTRUE OAK ‘M
ID 10m
m’
5
RR13.1
MILE END SOUTH SA55 Scotland Road
P: 08 8352 0911 F: 08 8352 0922
REGENCY PARK SA5-17 Taminga Street
P: 08 8352 0911 F: 08 8352 0922
LONSDALE SA14 Bredbo Street
P: 08 8186 0545 F: 08 8186 1341
OSBORNE PARK WA55b Hector Street
P: 08 9217 9011 F: 08 9204 5564
TRUE OAK ‘MID 10mm’
MATERIAL SPECIFICATIONS
ZINCALUME® steel base metal thickness is 0.42, and 0.48mm with an aluminium/zinc/magnesium alloy coating complying with AS1397 -2011 ( 550MPa minimum Yield Strength, 125g/m2 minimum metallic coating mass)
COLORBOND® steel base metal thickness is 0.35, 0.42, or 0.48mm with an aluminium/zinc/magnesium alloy coating substrate complying to AS1397 -2011 and Paint coating complying to AS/NZS 2728 Type 4 ( 550 MPa minimum Yield Strength, 100g/m2 minimum metallic coating mass)
COLORBOND® Ultra steel base metal thickness is 0.42, or 0.48mm with an aluminium/zinc/magnesium alloy coating substrate complying to AS1397 -2011 and Paint coating complying to AS/NZS 2728 Type 4 ( 550 MPa minimum Yield Strength, 150g/m2 minimum metallic coating mass)
COLORBOND® Matte Finish steel base metal thickness is 0.60mm with an aluminium/zinc/magnesium alloy coating substrate complying to AS1397 -2011 and Paint coating complying to AS/NZS 2728 Type 4 ( 300 MPa minimum Yield Strength, 100g/m2 minimum metallic coating mass)
Heritage Galvanised is a 0.60mm, Z600 hot dipped zinc-coated structural steel complying with AS1397-2001 G300 (300MPa minimum yield stress), 600g/m2 minimum coating mass
Note:1. For walling the data is based on wind pressure.2. When using as a soffit lining fastening the side laps mid
span will improve the overall appearance whilst not affecting the functionality of the product
3. All external fasteners should be fitted with a epdm washers.
Revolution Roofing TRUE OAK ‘MID’Recommended Maximum Support Spacings (mm) SPAN TABLE
Wall Span 0.42 BMT
Single Span 1500
End Span 1100
Internal Span 1500
Overhang 200
Ceiling or Soffit Span 0.42 BMT
Single Span 600
End Span 600
Internal Span 900
SPAN TABLE NON-CYCLONIC
DETAIL ASCALE 4
A
1
1
2
2
3
3
4
4
5
5
6
6
A A
B B
C C
D D
5 - 17 Taminga StreetREGENCY PARKSA 5031Phone - (08) 8352 0911Fax - (08) 8352 0922
835.25
797.93
8.89 TO CREST
9.56 TO TROUGH
37.96
R10.27 R12.85
R11.80 R11.66
.680 FROM CREST TO RADIUS CHANGE
5.04 5.18
4.76
4.90
9.95
.090 FROM TROUGH TO RADIUS CHANGE
49.6°63.2°
53.8° 54.1°
TRUE OAK 102:5
PLYMPTON PARK SA 576 Marion Road P: 08 8352 0990
REVSPECTRUE OAK ‘M
ID 10m
m’
6
TRUE OAK ‘MID 10mm’
MILE END SOUTH SA55 Scotland Road
P: 08 8352 0911 F: 08 8352 0922
REGENCY PARK SA5-17 Taminga Street
P: 08 8352 0911 F: 08 8352 0922
LONSDALE SA14 Bredbo Street
P: 08 8186 0545 F: 08 8186 1341
OSBORNE PARK WA55b Hector Street
P: 08 9217 9011 F: 08 9204 5564
TRUE OAK ‘MID’ MASSES
Colorbond
0.35 BMT 0.42 BMT 0.48 BMT 0.60 BMT
kg/lm 2.75 3.25 3.69 4.51
kg/m2 3.44 4.06 4.61 5.64
Zincalume
0.35 BMT 0.42 BMT 0.48 BMT 0.60 BMT
kg/lm 2.71 3.23 3.68 4.49
kg/m2 3.39 4.04 4.60 5.61
Heritage Galvanised
0.35 BMT 0.42 BMT 0.48 BMT 0.60 BMT
kg/lm - - - 4.98
kg/m2 - - - 6.23
Tolerances: Length: +7mm/ -7mm, Width: +4mm/ -4mm
True Oak Mid 10mm is available in 0.48 BMT Perforated which is ideal for ceilings and wall linings, stock colours are Colorbond Surf Mist and Zincalume.
Perforated Metal:• 11% open area• 2.38mm Diameter Hole• 6.74 Degree pitch
Non-Cyclonic 0.42 BMTNON-CYCLONIC Wind Uplift Resistance - Service and Strength Limit State Design
Span
(mm
) End Span
Span
(mm
) Internal Span
Serviceability (kPa)
Strength (kPa)
Serviceability (kPa)
Strength (kPa)
900 0.47 5.18 1200 0.46 4.87
1200 0.43 3.56 1500 0.43 3.58
1500 0.41 2.67 1800 0.41 2.79
1800 0.38 2.10 2100 0.39 2.12
Required Fixings: Screws: H.W.F head self drilling metal M4.8 - 16x25 Ripple Zips length + Seal (Buildex Screws) 7 Screws per sheet - Internal supports 7 Screws per sheet - End Supports Base Metal: Minimum steel purlin thickness, 1.5mm
PLYMPTON PARK SA 576 Marion Road P: 08 8352 0990
REVSPECTRUE OAK ‘M
ID 10m
m’
7
RR13.1
TRUE OAK ‘MID 10mm’
MILE END SOUTH SA55 Scotland Road
P: 08 8352 0911 F: 08 8352 0922
REGENCY PARK SA5-17 Taminga Street
P: 08 8352 0911 F: 08 8352 0922
LONSDALE SA14 Bredbo Street
P: 08 8186 0545 F: 08 8186 1341
OSBORNE PARK WA55b Hector Street
P: 08 9217 9011 F: 08 9204 5564
Suggested TRUE OAK ‘MID’ - Non Cyclonic Pierce Fixing
Type Fixing To Steel(Up to 1.9mm) Fixing To Timber
Valle
y Fixe
d(W
all O
nly)
Buildex Ripplezip M4.8-16 x 25 or 10-16 x 16mm Hex
Head
Buildex Ripplezip M4.8-16 x 25 or 10-12 x 25mm Hex
Head T17
RECOMMENDED FASTENERS
8 fasteners per sheet - end supports and end laps
Valley Fastener Location
Note: Side lap fasteners are optional.
FASTENER SPACING NON-CYCLONIC
Maximum Support Spacings
The maximum recommended support spacings are based on testing in accordance with AS1562.1-1992, AS4040.1-1992 and AS4040.2-1992. The wall spans take in to consideration the resistance to wind pressure only.
Lengths: Sheets are manufactured to your required length but for handling requirements a maximum length of 6.0m is rec-ommended for ceilings and soffits; an 8.0m maximum sheet length is recommended when used as a wall cladding
Note: After exposure of cladding to an extreme wind event, it is recommended that inspection be performed to confirm cladding integrity.* The above data displayed is based on trend data, which is a true representation of the average product capability.
Valley fixed fasteners for True Oak ‘MID’ ceiling and walling applications are Buildex Ripple Zips M4.8-16x25 which can be used for both steel and timber supports. Refer to Buildex Product Guide for ‘user’ instructions or visit www.buildex.com.au
FASTENERS
PLYMPTON PARK SA 576 Marion Road P: 08 8352 0990
REVSPECTRUE OAK ‘M
ID 10m
m’
8MILE END SOUTH SA
55 Scotland RoadP: 08 8352 0911 F: 08 8352 0922
REGENCY PARK SA5-17 Taminga Street
P: 08 8352 0911 F: 08 8352 0922
LONSDALE SA14 Bredbo Street
P: 08 8186 0545 F: 08 8186 1341
OSBORNE PARK WA55b Hector Street
P: 08 9217 9011 F: 08 9204 5564
This page has been intentionally left blank
PLYMPTON PARK SA 576 Marion Road P: 08 8352 0990
REVSPECTRUE OAK ‘DEEP 21m
m’
9
RR13.1
TRUE OAK ‘DEEP 21mm’
MILE END SOUTH SA55 Scotland Road
P: 08 8352 0911 F: 08 8352 0922
REGENCY PARK SA5-17 Taminga Street
P: 08 8352 0911 F: 08 8352 0922
LONSDALE SA14 Bredbo Street
P: 08 8186 0545 F: 08 8186 1341
OSBORNE PARK WA55b Hector Street
P: 08 9217 9011 F: 08 9204 5564
MATERIAL SPECIFICATIONS
ZINCALUME® steel base metal thickness is 0.40, and 0.48mm with an aluminium/zinc/magnesium alloy coating complying with AS1397 -2011 ( 550MPa minimum Yield Strength, 125g/m2 minimum metallic coating mass)
COLORBOND® steel base metal thickness is 0.35, 0.40, or 0.48mm with an aluminium/zinc/magnesium alloy coating substrate complying to AS1397 -2011 and Paint coating complying to AS/NZS 2728 Type 4 ( 550 MPa minimum Yield Strength, 100g/m2 minimum metallic coating mass)
COLORBOND® Ultra steel base metal thickness is 0.40, or 0.48mm with an aluminium/zinc/magnesium alloy coating substrate complying to AS1397 -2011 and Paint coating complying to AS/NZS 2728 Type 4 ( 550 MPa minimum Yield Strength, 150g/m2 minimum metallic coating mass)
COLORBOND® Matte Finish base metal thickness is 0.40mm with an aluminium/zinc/magnesium alloy coating substrate complying to AS1397 -2011 and Paint coating complying to AS/NZS 2728 Type 4 ( 550 MPa minimum Yield Strength, 100g/m2 minimum metallic coating mass)
Heritage Galvanised is a 0.40, or 0.48mm, Z600 hot dipped zinc-coated structural steel complying with AS1397-2001 G300 (550MPa minimum yield stress), 600g/m2 minimum coating mass
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
A A
B B
C C
D D
E E
F F
APPROVED BY:REV LETTER REV DESCRIPTION APPROVED DATE
SHEET 1 OF 1
TITLE:
SCALE AT A3 DRAWING NUMBER READ WITH
CADSYS: INVENTOR 16
PATH: \\FILESERVER\Engineering\CAD Documents\Inventor\Roof Profiles\Drawings\True Oak 21.idw
NAME SIGNED DATEDESIGNEDDRAWNCHECKEDAPPROVEDIMAGE No:REF. FILE No:
FILE No:CAD FILE No:
MATERIAL:FINISH: QTY: OFFTOLERANCES M/M
0
0.0
0.00
ANGLES
ALL DIMENSIONS IN MM UNLESS STATED
COPYRIGHTTHIS DRAWING IS THE PROPERTY OF
REVOLUTION ROOFING PTY LTDIT IS A CONFIDENTIAL DOCUMENT AND MUST NOTBE COPIED, REPRODUCED, USED OR ITS CONTENTS
DIVULGED WITHOUT PRIOR WRITTEN CONSENT
5 - 17 Taminga StreetREGENCY PARKSA 5031Phone - (08) 8352 0911Fax - (08) 8352 0922 2 : 5
True Oak 21
835.54
762.00
20.8
0
76.20
TRUE OAK 21
Revolution Roofing TRUE OAK ‘DEEP’ 21mmRecommended Maximum Support Spacings (mm) SPAN TABLE
Roof Span 0.35 BMT
0.40 BMT
0.48 BMT
0.60 BMTTrafficable
0.60 BMTControlled
Single Span 750 900 1500 1100 1500
End Span 900 1200 1700 1400 1900
Internal Span 1200 1400 2000 1800 2600
Unstiffened Overhang 200 250 300 300 300
Stiffened Overhang 350 400 450 N/A N/A
Wall Span 0.35 BMT
0.40 BMT
0.48 BMT 0.48 BMT
Single Span 1050 1850 2100 2100
End Span 1050 1850 1900 1900
Internal Span 1300 2100 2400 2400
Unstiffened Overhang 180 185 190 190
SPAN TABLE NON-CYCLONIC
Roof spans were based upon AS 4040.1 - Methods of testing sheet roof and wall cladding- Introduction, list of methods and general requirements. Point load tests were in accordance with AS 1562 - Design and installation of sheet roof and wall cladding.
MINIMUM ROOF PITCH 3 DEGREES To avoid capillary action Revolution Roofing recommend using the True Oak Turn Down tool on any roof pitch below 10 degrees.
PLYMPTON PARK SA 576 Marion Road P: 08 8352 0990
REVSPECTRUE OAK ‘M
ID 21mm’
10
TRUE OAK ‘DEEP 21mm’
MILE END SOUTH SA55 Scotland Road
P: 08 8352 0911 F: 08 8352 0922
REGENCY PARK SA5-17 Taminga Street
P: 08 8352 0911 F: 08 8352 0922
LONSDALE SA14 Bredbo Street
P: 08 8186 0545 F: 08 8186 1341
OSBORNE PARK WA55b Hector Street
P: 08 9217 9011 F: 08 9204 5564
STANDARD INTERPRETATION OF SPANS
Internal Span
End Span
End Span
O
O
Internal Span
End Span
End Span
O
O
O = Overhang
Single Span
End Bay
Internal Bay
Design Parameters
Internal End
KL 1.0 KL 2.0
∑C = -0.85 ∑C = -1.50
Pu = - 1.82 kPa
Ps = - 0.74 kPa
Region A:Terrain Category 2Height = 10mVz = 45m/secQ*u,s = 0.83 kPaCpe = +0.7/-0.65Cpi = -0.2/+0.2
Non-Cyclonic 0.35 BMTNON-CYCLONIC Wind Uplift Resistance –Service and Strength Limit State Design
Span
(mm
) End Span
Span
(mm
)
Internal Span
Serviceability (kPa)
Strength (kPa) Serviceability
(kPa)Strength
(kPa)
900 0.82 5.65 1200 0.80 5.24
1200 0.68 3.87 1500 0.69 3.93
1500 0.57 2.89 1800 0.60 3.10
1800 0.47 2.27 2100 0.52 2.54
Non-Cyclonic 0.48 BMTNON-CYCLONIC Wind Uplift Resistance - Service and Strength Limit State Design
Span
(mm
) End Span
Span
(mm
)
Internal Span
Serviceability (kPa)
Strength (kPa) Serviceability
(kPa)Strength
(kPa)
900 2.15 6.46 1200 1.98 6.11
1200 1.51 4.92 1500 1.51 4.95
1500 1.14 3.72 1800 1.21 3.99
1800* 1.02 3.21 2100* 1.01 3.19
Non-Cyclonic 0.40 BMTNON-CYCLONIC Wind Uplift Resistance - Service and Strength Limit State Design
Span
(mm
) End Span
Span
(mm
)
Internal Span
Serviceability (kPa)
Strength (kPa) Serviceability
(kPa)Strength
(kPa)
900 1.28 6.39 1200 1.23 6.08
1200 1.03 4.43 1500 1.05 4.62
1500 0.84 3.15 1800 0.90 3.51
1800* 0.68 2.26 2100* 0.77 2.60
TOLERANCE & MASSES
Colorbond
0.35 BMT 0.40 BMT 0.48 BMT 0.60 BMT
kg/lm 2.88 3.27 3.89 4.76
kg/m2 3.78 4.29 5.10 6.25
Zincalume
0.35 BMT 0.40 BMT 0.48 BMT 0.60 BMT
kg/lm 2.86 3.25 3.86 4.74
kg/m2 3.75 4.27 5.07 6.22
Heritage Galvanised
0.35 BMT 0.40 BMT 0.48 BMT 0.60 BMT
kg/lm - 3.78 4.39 5.32
kg/m2 - 4.96 5.76 6.98
Tolerances: Length: +7mm/ -7mm, Width: +4mm/ -4mm
Span
(m
m) Single Span
Serviceability (kPa)
Strength (kPa)
1200 2.77 10.93
1500 1.44 9.30
1800 0.84 7.96
2100* 0.54 6.84 * Span exceeds trafficable point loads.
PLYMPTON PARK SA 576 Marion Road P: 08 8352 0990
REVSPECTRUE OAK ‘M
ID 21mm’
TRUE OAK ‘DEEP 21mm’
11
RR13.1
TRUE OAK ‘DEEP 21mm’
MILE END SOUTH SA55 Scotland Road
P: 08 8352 0911 F: 08 8352 0922
REGENCY PARK SA5-17 Taminga Street
P: 08 8352 0911 F: 08 8352 0922
LONSDALE SA14 Bredbo Street
P: 08 8186 0545 F: 08 8186 1341
OSBORNE PARK WA55b Hector Street
P: 08 9217 9011 F: 08 9204 5564
Note: Side lap fasteners are optional when using 5 fasteners per sheet, but are a requirement when only using 3 fasteners per sheet for valleys.
3 fasteners per sheet - internal supports(roofing should be lapped away from prevailing weather)
Crest Fastener Location
5 fasteners per sheet - end supports and end laps
FASTENER SPACING NON-CYCLONIC
Note: After exposure of cladding to an extreme wind event, it is recommended that inspection be performed to confirm cladding integrity.
* The above data displayed is based on trend data, which is a true representation of the average product capability.
Maximum Support Spacings
The maximum recommended support spacings are based on testing in accordance with AS1562.1-1992, AS4040.1-1992 and AS4040.2-1992. The recommended roof spans take in to consideration both resistance to wind pressure and light roof traffic (traffic arising from maintenance). The wall spans take in to consideration the resistance to wind pressure only.
Suggested TRUE OAK ‘DEEP’ Non Cyclonic Pierce Fixing
TypeFixing To Steel(Up to 1.9mm)
Fixing To Steel(2.0mm - 3.5mm) Fixing To Timber
Cres
t Fixe
d
M6.2-13 x 50mm Hex Head HiGrip
w/- Seal
Self Drilling 12-14 x 35mm Hex Head HiGrip w/- Seal
M6.2 -13x50mm or65mm T17 Timber
Valle
y Fixe
d(W
all O
nly) M6.2 -13x25mm or
10-16 x 16mm Metal Teks Hexagon Head
with Seal-
M6.2 -13x25mm or 10-12 x
25mm T17
Crest Fixing: 5 Fasteners Per Sheet Single Span Crest Fixing: 3 Fasteners Per Sheet End and Internal Spans
PLYMPTON PARK SA 576 Marion Road P: 08 8352 0990
REVSPEC
TRUE OAK ‘DEEP 21mm’
TRUE OAK ‘MID 21m
m’
12
TRUE OAK ‘DEEP 21mm’
MILE END SOUTH SA55 Scotland Road
P: 08 8352 0911 F: 08 8352 0922
REGENCY PARK SA5-17 Taminga Street
P: 08 8352 0911 F: 08 8352 0922
LONSDALE SA14 Bredbo Street
P: 08 8186 0545 F: 08 8186 1341
OSBORNE PARK WA55b Hector Street
P: 08 9217 9011 F: 08 9204 5564
Note:1. Analysis based upon steady state of flow and Manning
formula with n=0.222.2. Analysis based upon depth of flow 9.5mm (sheet overlap
consider to be 2mm above the line of flow) .3. Analysis doesn’t consider thermal limitations on
maximum length, refer to Revolution Roofing for details.4. The above tables do not consider gutter and downpipe
requirements.
MAXIMUM ROOF LENGTHS FOR DRAINAGE
55 50
45 40
35 30 25
1 2 3 4 5
Max
imum
She
et L
engt
h
Roof Slope (degrees)
100mm/hr150mm/hr 200mm/hr 250mm/hr300mm/hr350mm/hr400mm/hr
***Revolution Roofing recommends a minimum pitch of 3 degrees when using True Oak Superior ‘DEEP.’
Note: Arbitrary length limit, refer Revolution Roofing for specific extensions.
TRUE OAK SUPERIOR ‘DEEP’ Rainfall Capacity Maximum Roof Length for Drainage
Roof Slope (degrees)
Rainfall Capacity (mm/hr)
100 150 200 250 300 350 400
1 24 16 12 9 8 6 6
2 34 22 17 13 11 9 8
3 41 27 20 16 13 11 10
4 48 32 24 19 16 13 12
5 54* 36 27 21 18 15 13
RAINFALL CAPACITY & DRAINAGE CHARTS
PLYMPTON PARK SA 576 Marion Road P: 08 8352 0990
REVSPECTRUE OAK ‘SUPER 5’
13
RR13.1
TRUE OAK ‘SUPER 5’REVSPEC
MILE END SOUTH SA55 Scotland Road
P: 08 8352 0911 F: 08 8352 0922
REGENCY PARK SA5-17 Taminga Street
P: 08 8352 0911 F: 08 8352 0922
LONSDALE SA14 Bredbo Street
P: 08 8186 0545 F: 08 8186 1341
OSBORNE PARK WA55b Hector Street
P: 08 9217 9011 F: 08 9204 5564
MATERIAL SPECIFICATIONSZINCALUME® steel base metal thickness is 0.48mm with an aluminium/zinc/magnesium alloy coating complying with AS1397 -2011 ( 550MPa minimum Yield Strength, 125g/m2 minimum metallic coating mass)
COLORBOND® steel base metal thickness is 0.48mm with an aluminium/zinc/magnesium alloy coating substrate complying to AS1397 -2011 and Paint coating complying to AS/NZS 2728 Type 4 (550 MPa minimum Yield Strength, 100g/m2 minimum metallic coating mass)
COLORBOND® Ultra steel base metal thickness is 0.48mm with an aluminium/zinc/magnesium alloy coating substrate complying to AS1397 -2011 and Paint coating complying to AS/NZS 2728 Type 4 ( 550 MPa minimum Yield Strength, 150g/m2 minimum metallic coating mass)
COLORBOND® Matte Finish base metal thickness is 0.48mm with an aluminium/zinc/magnesium alloy coating substrate complying to AS1397 -2011 and Paint coating complying to AS/NZS 2728 Type 4 ( 550 MPa minimum Yield Strength, 100g/m2 minimum metallic coating mass)
Heritage Galvanised is 0.48mm, Z600 hot dipped zinc-coated structural steel complying with AS1397-2001 G300 (550MPa minimum yield stress), 600g/m2 minimum coating mass
Trafficable Roof Span: Assumed that foot traffic is distributed over a minimum of two ribs at any one time.
Note:1. For roofing the data is based on foot traffic loading.2. For walling the data is based on wind pressure.3. The above data table is based on supports of 1mm BMT.
Revolution Roofing TRUE OAK ‘SUPER 5’Recommended Maximum Support Spacings (mm) SPAN TABLE
Roof Span 0.48 BMT
0.60BMT
Single Span 1200 1200
End Span 1800 1800
Internal Span 2400 2400
Wall Span 0.48 BMT
Single Span 2200
End Span 2200
Internal Span 2200
SPAN TABLE NON-CYCLONIC
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
A A
B B
C C
D D
E E
F F
APPROVED BY:REV LETTER REV DESCRIPTION APPROVED DATE
SHEET 1 OF 1
TITLE:
SCALE AT A3 DRAWING NUMBER READ WITH
CADSYS: INVENTOR 16
PATH: \\FILESERVER\Engineering\CAD Documents\Inventor\Roof Profiles\Drawings\Super 5.idw
NAME SIGNED DATEDESIGNEDDRAWNCHECKEDAPPROVEDIMAGE No:REF. FILE No:
FILE No:CAD FILE No:
MATERIAL:FINISH: QTY: OFFTOLERANCES M/M
0
0.0
0.00
ANGLES
ALL DIMENSIONS IN MM UNLESS STATED
COPYRIGHTTHIS DRAWING IS THE PROPERTY OF
REVOLUTION ROOFING PTY LTDIT IS A CONFIDENTIAL DOCUMENT AND MUST NOTBE COPIED, REPRODUCED, USED OR ITS CONTENTS
DIVULGED WITHOUT PRIOR WRITTEN CONSENT
5 - 17 Taminga StreetREGENCY PARKSA 5031Phone - (08) 8352 0911Fax - (08) 8352 0922 2 : 5
Super 5
844.00
735.00
122.50 35.0
0
TRUE OAK 5
MINIMUM ROOF PITCH 2 DEGREES To avoid capillary action Revolution Roofing recommend using the True Oak Turn Down tool on any roof pitch below 10 degrees.
Note: The True Oak Super 5” in 0.60 BMT Curving Quality G300 has an effec-tive coverage of 720mm.
PLYMPTON PARK SA 576 Marion Road P: 08 8352 0990
REVSPECTRUE OAK ‘SUPER 5’
14
TRUE OAK ‘ SUPER 5’
MILE END SOUTH SA55 Scotland Road
P: 08 8352 0911 F: 08 8352 0922
REGENCY PARK SA5-17 Taminga Street
P: 08 8352 0911 F: 08 8352 0922
LONSDALE SA14 Bredbo Street
P: 08 8186 0545 F: 08 8186 1341
OSBORNE PARK WA55b Hector Street
P: 08 9217 9011 F: 08 9204 5564
Design Parameters
STANDARD INTERPRETATION OF SPANS
Internal End
KL 1.0 KL 2.0
∑C = -0.85 ∑C = -1.50
Pu = 1.82 kPa
Ps = 0.74 kPa
Region A:Terrain Category 2Height = 10mVz = 45m/secQ*u,s = 0.83 kPaCpe = +0.7 / -0.65Cpi = -0.20 / +0.2
Note: Table limits for walls based on pressures stated in above table.
Non-Cyclonic 0.48 BMTNON-CYCLONIC wind uplift Resistance - Service and Strength Limited
State Design
Span
(mm
)
End Span
Span
(mm
)
Internal Span
Serviceability (kPa)
Strength (kPa)
Serviceability (kPa)
Strength (kPa)
1200 2.04 6.08 1200 2.06 6.16
1500 1.66 4.60 1500 1.74 4.88
1800 1.35 3.66 1800 1.47 4.02
2100 1.08 3.02 2100 1.24 3.39
2400 0.86 2.56 2400 1.04 2.92
TOLERANCES & MASSES
Colorbond
0.48 BMT 0.60 BMT
kg/lm 3.89 4.76
kg/m2 5.29 6.61
Zincalume
0.48 BMT 0.60 BMT
kg/lm 3.86 4.74
kg/m2 5.25 6.58
Heritage Galvanised
0.48 BMT 0.60 BMT
kg/lm 4.39 5.32
kg/m2 5.97 7.39
Internal Span
End Span
End Span
O
O
Internal Span
End Span
End Span
O
O
O = Overhang
Single Span
End Bay
Internal Bay
Tolerances: Length: +7mm/ -7mm, Width: +4mm/ -4mm
PLYMPTON PARK SA 576 Marion Road P: 08 8352 0990
REVSPECTRUE OAK ‘SUPER 5’
15
RR13.1
TRUE OAK ‘SUPER 5’
MILE END SOUTH SA55 Scotland Road
P: 08 8352 0911 F: 08 8352 0922
REGENCY PARK SA5-17 Taminga Street
P: 08 8352 0911 F: 08 8352 0922
LONSDALE SA14 Bredbo Street
P: 08 8186 0545 F: 08 8186 1341
OSBORNE PARK WA55b Hector Street
P: 08 9217 9011 F: 08 9204 5564
Suggested TRUE OAK ‘SUPER 5’ - Non Cyclonic Pierce Fixing
Type Fixing To Steel(Up to 1.9mm)
Fixing To Steel(2.0mm - 3.5mm)
Fixing To Timber
Cres
t Fixe
d
M6.2-13 x 50mm Hex Head HiGrip w/- Seal
Self Drilling 14-14 x 68mm Hex Head HiGrip w/- Seal
M6.2 -13x65mm or 65mm T17
Timber
Valle
y Fixe
d(W
all O
nly) M6.2 -13x25mm or
10-16 x 16mm Metal Teks Hexagon Head
with Seal
M6.2 -13x25mm or 10-12 x 25mm T17
RECOMMENDED FASTENERS
Note: Side lap fasteners are optional when using 6 fasteners per sheet.
3 fasteners per sheet - internal supports(roofing should be lapped away from prevailing weather)
6 fasteners per sheet - end supports and end laps
Crest Fastener Location - Roofing
FASTENER SPACING NON-CYCLONIC
Crest: 6 Fasteners Per Sheet - End Supports and End Laps
Crest: 3 Fasteners for Internal Supports
FASTENER SPACING CYCLONIC
6 fasteners per sheet - end supports and end laps
Crest Fastener Location
6 fasteners per sheet - internal supports(roofing should be lapped away from prevailing weather)
Crest: 6 Fasteners Per Sheet - End Supports and End Laps
Crest: 6 Fasteners Per Sheet - End Supports and End Laps
Strength Limit State Design Pressure
Span(mm)
End Span (Test)Stregth (kPa)
Span(mm)
Internal Span (Test)Strength (kPa)
950 5.72 1200 5.72
NCC 2014 (also known as the Building Code of Australia)• Volume 1: Specification B1.2 - Class 2 to 9 buildings• Volume 2: Part 3.10.1 - Class 1 and 10 buildings.
AS 1562.1 - 1992 - Design and installation of sheet roof and wall cladding (Amdt 3-2012)
AS 4040 - 1992 - Methods of testing sheet roof and wall cladding • Part 0: Introduction, list of methods and general
requirements• Method 3: Methods of testing sheet roof and wall
cladding - Resistance to wind pressures for cyclone regions, pressure test regime as per BCA Lo-Hi-Lo.
Note: It is recommended that a qualified structural engineer check the suitability of the Limit State Design Wind Pressures for the intended site of use. It is our opinion that a qualified structural engineer may extrapolate for shorter spans and higher pressures provided that the screw force is not exceeded.After exposure of cladding to an extreme wind event, it is recommended that inspection be performed to confirm fixing and cladding integrity.
Windborne Debris Impact Testing Roof Application - Vertical Trajectories
Target Velocity - Vertical Trajectories
Timber Member: 8.8m/sSpherical steel ball: 26.4 m/s
Equivalent Regional Wind Speed (V500 )
Vr=88m/s (Region D)
Tested SheetingType: True Oak ‘Super 5’Base metal thickness: 0.48bmtMaterial grade: G550
Tested Spans Triple Equal Span: 1200mm
AS/NZS 1170.2 :2011Structural Design Actions, Part 2: Wind actions, Section 2.5 Wind actions, Part 2.5.8 Impact loading from windborne debris - Vertical Trajectories (Roofing)
CTS Technical Note No.4 Simulated Windborne Debris Impact Testing of Building Envelope Components (Version 3)
PLYMPTON PARK SA 576 Marion Road P: 08 8352 0990
REVSPECTRUE OAK ‘SUPER 5’
16MILE END SOUTH SA
55 Scotland RoadP: 08 8352 0911 F: 08 8352 0922
REGENCY PARK SA5-17 Taminga Street
P: 08 8352 0911 F: 08 8352 0922
LONSDALE SA14 Bredbo Street
P: 08 8186 0545 F: 08 8186 1341
OSBORNE PARK WA55b Hector Street
P: 08 9217 9011 F: 08 9204 5564
This page has been intentionally left blank
PLYMPTON PARK SA 576 Marion Road P: 08 8352 0990
REVSPECTRUE OAK ‘M
ID 10m
m’
17
RR13.1
TRUE OAK CORRUGATED CURVING TRUE OAK CORRUGATED CURVINGREVSPEC
MILE END SOUTH SA55 Scotland Road
P: 08 8352 0911 F: 08 8352 0922
REGENCY PARK SA5-17 Taminga Street
P: 08 8352 0911 F: 08 8352 0922
LONSDALE SA14 Bredbo Street
P: 08 8186 0545 F: 08 8186 1341
OSBORNE PARK WA55b Hector Street
P: 08 9217 9011 F: 08 9204 5564
For details regarding Smooth Curving of the True Oak Profiles please see Roofing and Cladding section.
BULLNOSE CONVEXCONCAVE
S CURVE RIDGE CURVETRADITIONAL 8 FLUTE
FULL CIRCLE‘DEEP 21mm’
FULL CIRCLE‘MID 10mm’
Maximum Radius
Deep 21: 350mmSuper 5”: N/AMid 10: N/A
Minimum Dip
Deep 21: 75mmSuper 5”: 100 mm
Mid 10: 75 mm
Maximum Radius
Deep 21: 1000mmSuper 5”: 2500mmMid 10: 1000mm
PLYMPTON PARK SA 576 Marion Road P: 08 8352 0990
REVSPECTRUE OAK CORRUGATED CURVING
18
TRUE OAK CORRUGATED CURVING
MILE END SOUTH SA55 Scotland Road
P: 08 8352 0911 F: 08 8352 0922
REGENCY PARK SA5-17 Taminga Street
P: 08 8352 0911 F: 08 8352 0922
LONSDALE SA14 Bredbo Street
P: 08 8186 0545 F: 08 8186 1341
OSBORNE PARK WA55b Hector Street
P: 08 9217 9011 F: 08 9204 5564
The measurements above will be required for Revolution Roofing to work out the sheet length required. Where the sheet is going in to the gutter 50mm will be added to the overall sheet length.
MATERIAL SPECIFICATIONS
ZINCALUME® steel base metal thickness is 0.60mm with an aluminium/zinc/magnesium alloy coating complying with AS1397 (300MPa minimum yield strength, 125g/m2 minimum metallic coating mass).
COLORBOND® steel base metal thickness is 0.60mm with an aluminium/zinc/magnesium alloy coating substrate complying to AS1397 and Paint coating complying to AS/NZS 2728 Type 4 ( 300 MPa minimum Yield Strength, 100g/m2 minimum metallic coating mass).
COLORBOND® Ultra steel base metal thickness is 0.60mm with an aluminium/zinc/magnesium alloy coating substrate complying to AS1397 and Paint coating complying to AS/NZS 2728 Type 4 ( 300 MPa minimum Yield Strength, 150g/m2 minimum metallic coating mass).
Heritage Galvanised is a 0.60mm, Z600 hot dipped zinc-coated structural steel complying with AS1397-2001 G300 (300MPa minimum yield stress), 600g/m2 minimum coating mass.
A
B
C
500mm
D
5°
RADI
US
BULL NOSE
B
A
CONVEX
D
H XCONCAVE
A
B
D
C
RIDGE CURVE
PLYMPTON PARK SA 576 Marion Road P: 08 8352 0990
REVSPECTRUE OAK ‘M
ID 10m
m’
19
RR13.1
TRUE OAK CORRUGATED CURVINGREVSPEC
MILE END SOUTH SA55 Scotland Road
P: 08 8352 0911 F: 08 8352 0922
REGENCY PARK SA5-17 Taminga Street
P: 08 8352 0911 F: 08 8352 0922
LONSDALE SA14 Bredbo Street
P: 08 8186 0545 F: 08 8186 1341
OSBORNE PARK WA55b Hector Street
P: 08 9217 9011 F: 08 9204 5564
PLYMPTON PARK SA 576 Marion Road P: 08 8352 0990