Reverse osmosis project

9
RODDING SHOP Reverse Osmosis Plant

description

 

Transcript of Reverse osmosis project

Page 1: Reverse osmosis project

RODDING SHOP

Reverse Osmosis Plant

Page 2: Reverse osmosis project

RODDING SHOP

Process flow diagram of RO

Page 3: Reverse osmosis project

RODDING SHOPWhy RO is Required

• Effluent treatment through Reverse Osmosis in Aluminum smelter is a exemplary implementation in the country with complete management of RO reject through forced evaporation in solar ponds.

• This provides the treated effluent the fitness to be re used in any process application inside the plant leading to 100% recycling.

• This reduces plant's fresh water consumption resulting in water saving and conservation of natural resources.

• Fluoride reduction in the treated effluent to a level of <1ppm eliminates water pollution and provides a safe environment.

Page 4: Reverse osmosis project

RODDING SHOPSalient Features

•It has 50 m3/hour effluent treatment capacity.

•Use of conventional water filtration techniques like Sand Filters and Activated Carbon Filters with state of art techniques like Ultrafiltration System and Reverse Osmosis filtration to get highest level of purity.

•Use of RO technology for effluent treatment particularly fluoride in aluminium smelter effluent is one of its kind in major smelting industry. •Accelerated RO reject evaporation through installation of mist fans (atomizers) for increasing surface areas of the rejects.

•Use of solar panels for heating the air which is blown through the RO rejects for faster evaporation.

•Advantage over other fluoride treatment options like ion exchange methods where in regeneration of resin, resin replacement and other operational inefficiencies are involved.

Page 5: Reverse osmosis project

RODDING SHOP Reverse Osmosis – Impact on effluents

Impact of Reverse Osmosis on effluents – Fluoride Level <1 ppm

Page 6: Reverse osmosis project

RODDING SHOPKey Benefits of RO

•Fully automated system without any manual intervention.

•Consistency in output treated water quality even with variant inputs.

•Ensures hygienic working environment and reduces operators' exposure to hazards.

•Recycling of effluent water for any industrial application.

•This system can be used for treating fluoride contaminated ground water for domestic application.

•Zero discharge industrial wastes to ambient water.

Page 7: Reverse osmosis project

RODDING SHOPUltra-Filtration & Reverse Osmosis snap shot

Sand and Carbon filters Ultra Filtration

Page 8: Reverse osmosis project

RODDING SHOPUltra-Filtration & Reverse Osmosis snap shot

RO FilterSolar Heaters and Mist Fan

Page 9: Reverse osmosis project

RODDING SHOP

Thank you