Retrofitting Techniques employing RC infilling of frame ... Earthquake/Stathis Bousias... ·...

30
University of Patras Structures Lab Retrofitting Techniques employing RC infilling of frame structures Stathis BOUSIAS Dept of Civil Engineering, Univ. of Patras Structures Laboratory

Transcript of Retrofitting Techniques employing RC infilling of frame ... Earthquake/Stathis Bousias... ·...

University of Patras Structures Lab

Retrofitting Techniques employing RC infilling of

frame structures

Stathis BOUSIAS Dept of Civil Engineering, Univ. of Patras

Structures Laboratory

Dep

t of C

ivil

Eng

inee

ring

– S

truc

ture

s La

b

Dep

t of C

ivil

Eng

inee

ring

– S

truc

ture

s La

b

Dep

t of C

ivil

Eng

inee

ring

– S

truc

ture

s La

b Retrofitting sub-standard structures

• Scope – Structural problem : “light” strengthening via RC walls – PsD testing problem : testing of stiff systems is prone to

control errors

• Scale ¾

Dep

t of C

ivil

Eng

inee

ring

– S

truc

ture

s La

b Mode shapes

mode Period (sec) Part. Factor Model mass (%) 2η 0.6114 16.08 74.53 6η 0.1783 6.85 13.54 7η 0.0865 4.73 6.45

Dep

t of C

ivil

Eng

inee

ring

– S

truc

ture

s La

b Wall reinforcement

Dep

t of C

ivil

Eng

inee

ring

– S

truc

ture

s La

b Design of the connection to frame

• Design shear forces : elastic shear forces magnified by

• New fib Model Code used for dimensioning

• Two approaches for the connection: – A : Wall reinforcement spliced with equal diameter anchors.

Additionally, one row of dowels is placed to resist shear

– B : One row of bars (dowels + anchors) along mid-width at centers of ¼ of the wall reinforcement spacing

Dep

t of C

ivil

Eng

inee

ring

– S

truc

ture

s La

b

A

A

B

B

Dep

t of C

ivil

Eng

inee

ring

– S

truc

ture

s La

b Scheme A

• Dowels (16mm,130+130mm) • Anchors (10/8 mm, 130+590mm)

A

A

Dep

t of C

ivil

Eng

inee

ring

– S

truc

ture

s La

b

16mm bars acting both as dowels & anchors Embedment length 130+590mm

B

B

Dep

t of C

ivil

Eng

inee

ring

– S

truc

ture

s La

b

Dep

t of C

ivil

Eng

inee

ring

– S

truc

ture

s La

b

Dep

t of C

ivil

Eng

inee

ring

– S

truc

ture

s La

b

Dep

t of C

ivil

Eng

inee

ring

– S

truc

ture

s La

b

Dep

t of C

ivil

Eng

inee

ring

– S

truc

ture

s La

b Acquisition - visualization

• 96 acquisition channels • 13 network cameras • Photogrammetry at ground floor

Dep

t of C

ivil

Eng

inee

ring

– S

truc

ture

s La

b Measurement system

Dep

t of C

ivil

Eng

inee

ring

– S

truc

ture

s La

b Tele-presence

Telepresence Client

Data Collector

Telepresence Server

Internet

Lab.. Network

Test Structure

Controller

Network Camera

Virtual Network

Data Acquisition

Dep

t of C

ivil

Eng

inee

ring

– S

truc

ture

s La

b Cyclic test - Repair

-80 -60 -40 -20 0 20 40 60 80

-250-200-150-100

-500

50100150200250

Μετακίνηση Κορυφής (mm)

Τέμν

ουσα

Βάσ

ης (k

N)

-0.89 -0.67 -0.44 -0.22 0 0.22 0.44 0.67 0.89Σχετική Μετακίνηση (%)

Dep

t of C

ivil

Eng

inee

ring

– S

truc

ture

s La

b Hybrid test at 0.25g

0 2 4 6 8 10 12 14 16 18-400-350-300-250-200-150-100

-500

50100150200250300350400

Χρόνος (sec)

Τέμ

νουσ

α Β

άσης

(kN

)

Τέμνουσα Βάσης 1ης ΙδιομορφήςΤέμνουσα Βάσης

0 2 4 6 8 10 12 14 16 18-100

-75

-50

-25

0

25

50

75

100100

Χρόνος (sec)

Μετ

ακίν

ηση

(mm

)

4ος Όροφος3ος Όροφος2ος Όροφος1ος Όροφος

Floor Displacement history Modal contribution

Dep

t of C

ivil

Eng

inee

ring

– S

truc

ture

s La

b 2nd Test

• Less interface reinforcement – FRP placed from the start • Equally satisfactory response

Dep

t of C

ivil

Eng

inee

ring

– S

truc

ture

s La

b Frame-wall separation

1st test 2nd test

Dep

t of C

ivil

Eng

inee

ring

– S

truc

ture

s La

b Conclusions

• Retrofitted specimens fail in flexure, if failure of inadequate lap splicing is precluded (at least at the base section).

• The infilling sustained no damage. • Longitudinal beam cracking needs special measures

• Overall the technique seems structurally reliable and

economically efficient.

Dep

t of C

ivil

Eng

inee

ring

– S

truc

ture

s La

b Forthcoming Tests

Retrofitting substandard buildings

Use Textile Reinforced Mortar (TRM) technique (Triantafillou et. al) to convert existing masonry infill walls into a reliable resisting system

Dep

t of C

ivil

Eng

inee

ring

– S

truc

ture

s La

b Past activities – Deficient Columns

Dep

t of C

ivil

Eng

inee

ring

– S

truc

ture

s La

b Substandard 2-storey structure

Scale 0.7:1

“stiff” side

“flexible” side

Dep

t of C

ivil

Eng

inee

ring

– S

truc

ture

s La

b

20

0 m

m

150

mm

Dep

t of C

ivil

Eng

inee

ring

– S

truc

ture

s La

b Retrofitting techniques

FRP

Soft storey

Dep

t of C

ivil

Eng

inee

ring

– S

truc

ture

s La

b

RC jacket

Textile-Reinforced Mortar (TRM)

Dep

t of C

ivil

Eng

inee

ring

– S

truc

ture

s La

b

Free vibration

test

Dep

t of C

ivil

Eng

inee

ring

– S

truc

ture

s La

b