RET Installation 9362371b

download RET Installation 9362371b

of 32

Transcript of RET Installation 9362371b

  • 8/3/2019 RET Installation 9362371b

    1/32

    Manual

    RETRemote Electrical Tilt

  • 8/3/2019 RET Installation 9362371b

    2/32

    Content

    2

    Content

    Content ............................................................................................................................................................. 2General Information......................................................................................................................................... 3Safety Instructions .......................................................................................................................................... 4

    General Instructions .................................................................................................................................... 4Extraordinary Operating Conditions.......................................................................................................... 4Grounding and Lightning Protection......................................................................................................... 4Mains Lead.................................................................................................................................................... 5Restricted Area............................................................................................................................................. 5Lightning Activity......................................................................................................................................... 5Repair ............................................................................................................................................................ 5Connections ................................................................................................................................................. 6Mains Supply................................................................................................................................................ 6Ventilation..................................................................................................................................................... 6Temperature ................................................................................................................................................. 6Waste disposal............................................................................................................................................. 6

    Regulatory Compliance .................................................................................................................................. 7FCC Class A and Class B Statements ....................................................................................................... 7FCC Compliance for Class A Equipment .................................................................................................. 7FCC Compliance for Class B Equipment .................................................................................................. 7CE Marking ................................................................................................................................................... 7

    1. RET-System Overview ................................................................................................................................ 81.3 System Components ............................................................................................................................. 9

    1.3.1 Remote Control Unit (RCU)............................................................................................................... 91.3.2 Central Control Unit (CCU).............................................................................................................. 101.3.3 Connection Cables.......................................................................................................................... 121.3.4 Splitter for DC Power and Signal..................................................................................................... 131.3.5 Lightning Protection Device............................................................................................................. 141.3.6 Tower Mounted Amplifier ................................................................................................................ 151.3.7 Smart Bias Tee (800 2170 MHz).................................................................................................. 17

    1.4 RET System Control ............................................................................................................................ 182. Installation Instructions ............................................................................................................................ 19

    2.1 Attachment of RCU .............................................................................................................................. 192.2 Control Cable Installation ................................................................................................................... 202.3 Grounding and Lightning Protection................................................................................................. 212.4 Installation/Operation of the RET-System......................................................................................... 22

    3. RCU and CCU Connection Examples...................................................................................................... 253.1 Overview ............................................................................................................................................... 253.2 In General.............................................................................................................................................. 263.3 Use of Control Cable ........................................................................................................................... 26

    3.3.1 Connection of up to 3 RCUs............................................................................................................ 273.3.2 Connection of up to 6 RCUs............................................................................................................ 273.3.3 Connection of up to 9 RCUs............................................................................................................ 28

    3.4 Use of Smart Bias Tees....................................................................................................................... 293.5 Use of TMAs ......................................................................................................................................... 30

    4. Abbreviation Index .................................................................................................................................... 31Contact Addresses........................................................................................................................................ 32

  • 8/3/2019 RET Installation 9362371b

    3/32

    General Information

    3

    General Information

    The information published in this manual was up to date on the date of re-lease. However, we reserve the right to make changes without prior notice.

    This manual does not contain any descriptions of the CCU browser applica-tion. This is included in a separate Central Control Unit Software Description,which is delivered with each CCU.

  • 8/3/2019 RET Installation 9362371b

    4/32

    Safety Instructions

    4

    Safety Instructions

    Definitions

    Indicates a potentially dangerous situation.Death or severe injuries may occur.

    Provides information on ensuring the safety of persons or objects.

    General Instructions

    Details given on our data sheets and in this manual must be followed carefullyboth during installation and operation of the RET components!The installation team must be properly qualified and also be familiar with the

    relevant national safety regulations!Non-observance of these instructions may damage or destroy the devices.Death or severe injuries may occur!

    Extraordinary Operating Conditions

    Extraordinary operating conditions must be considered during the site planningprocess!

    Extraordinary operating conditions, such as heavy icing or exceptional dynamic

    stress (e.g. strain caused by oscillating support structures), may result in thesupporting structure, antenna or a RET component breaking, or even cause it tofall to the ground!

    As a result of more stringent legal regulations and judgments regarding productliability, we are obliged to point out certain risks that may arise when productsare used under extraordinary operating conditions.The mechanical design of the outdoor RET components is based on the envi-ronmental conditions as stipulated in ETS 300 019-1-4, class 4.1.E, which in-clude the static mechanical load imposed on an RET component by wind atmaximum velocity.The mechanical design of the Central Control Unit is based on the environ-mental conditions as stipulated in ETS 300 019-1-3, Class 3.3.

    The RET system conforms with lightning protection Class III according to VDE0185, Part 100 / ENV61024-1.

    Grounding and Lightning Protection

    RET equipment has to be grounded according to the relevant local regulations!(In Germany VDE 0855-300)Reliable earthing of rack-mounted equipment should be maintained. Particularattention should be given to supply connections other than direct connections

    to the branch circuit (e.g. use of power strips).

    Non-observance of the instructions above may damage or destroy the devices.Death or severe injuries may occur.

    WARNING

    WARNING

    WARNING

    WARNING

    NOTICE

  • 8/3/2019 RET Installation 9362371b

    5/32

    Safety Instructions

    5

    Mains Lead

    Make sure that the mains lead (power supply lead) is undamaged!

    Turn off external primary AC and DC power supply before connecting power ca-

    bles. Never put the Central Control Unit into operation if the mains lead is dam-aged! This can jeopardize the electrical safety of the Central Control Unit!

    Restricted Area

    This unit is intended for installation in restricted access areas. A restricted ac-cess area can be accessed only through the use of a special tool, lock and key,or other means of security.

    Lightning Activity

    Do not work on the system or connect or disconnect cables during periods oflightning activity.Non-observance of these instructions may damage or destroy the devices.

    Death or severe injuries may occur!

    Before connecting the equipment, check the polarity of the DC cable!

    Repair

    Only qualified specialists should carry out repairs and adjustments to your RETcomponents!

    Unauthorised tampering with the devices can jeopardize the electrical safety ofthe RET components!

    Non-observance of the instructions above may damage or destroy the devices.Death or severe injuries may occur!

    The manufacturer is not liable for any accidents or injuries as a result of open-ing the RET components.

    Unauthorised opening of the RET components and any unauthorised attempt torepair them entail loss of guarantee.

    WARNING

    WARNING

    NOTICE

    WARNING

    WARNING

  • 8/3/2019 RET Installation 9362371b

    6/32

    Safety Instructions

    6

    Connections

    The connections of the RET components have to be suitably wired up!

    The RET components may be rendered inactive or will not function properly ifthe connections are not suitably wired up.

    Mind the connection of the equipment to the supply circuit and the effect thatoverloading of the circuits might have on the over current protection and thesupply wiring.

    Appropriate consideration of equipment nameplate and datasheet ratingsshould be used when addressing this concern.

    Mains Supply

    Only operate the Central Control Unit using the mains voltage indicated on thedata sheet.

    Non-observance of these instructions may result in unsuccessful operation ofthe RET components or destruction of the devices!

    Ventilation

    If the equipment is to be installed on a rack, make sure that the air flow requiredfor safe operation of the equipment is not impeded.

    Never install the Central Control Unit in a cabinet, shelf or rack with inadequate

    ventilation!

    Never occlude the cooling slots on the unit!

    Heat accumulation may occur and result in destruction of the device.

    Temperature

    Do not exceed the ambient temperature limit as stated in the individual datasheets!

    Heat accumulation may occur and result in destruction of the device.If the equipment is installed in a closed or multi-unit rack assembly, the operat-ing ambient temperature of the rack environment may be higher than the ambi-ent room temperature. Therefore, install the equipment in an environment wherethe maximum ambient temperature limit (Tma) specified by the manufacturer isprovided.

    Waste disposal

    Ultimate waste disposal of this product should be handled according to all na-tional laws and regulations.

    NOTICE

    NOTICE

    NOTICE

    NOTICE

    NOTICE

  • 8/3/2019 RET Installation 9362371b

    7/32

    Regulatory Compliance

    7

    Regulatory Compliance

    FCC Class A and Class B Statements

    This section lists the Class A and Class B statements for the Kathrein CCU (Central Con-trol Unit). The information for users of Class A products is included in this section in the

    event that EMC performance is degraded due to the addition of a Class A product.

    This product has been tested and verified to meet Class B requirements as defined inCFR 47 part 15 for the United States an in EN55022 as well as CISPR 22 for Europe andother international marketplaces. This product has been tested in its customer orderableand shippable configuration, including certain port adapters and accessories representa-tive of typical customer applications and meets Class B requirements.If you add any additional accessories or other features to this product that are tested andmeet requirements that are less than Class B (i.e., Class A), then the product may as-sume the behavior and characteristics of a Class A device. Class A products producemore RF emissions than a Class B product and may cause allowable interference toother products.

    FCC Compliance for Class A EquipmentModifying the equipment without Kathreins authorization may result in the equipment nolonger complying with FCC requirements for Class A or Class B digital devices. In thatevent, your right to use the equipment may be limited by FCC regulations, and you maybe required to correct any interference to radio or television communications at yourown expense.

    For Class A equipment:

    This equipment has been tested and found to comply with the limits for a Class A digitaldevice, pursuant to Part 15 of the FCC rules. These limits are designed to provide rea-sonable protection against harmful interference when the equipment is operated in acommercial environment. This equipment generates, uses, and can radiate radio fre-quency energy and, if not installed and used in accordance with the instructions manual,may cause harmful interference to radio communications. Operation of this equipment ina residential area is likely to cause harmful interference in which case the user will be re-quired to correct the interference at this own expense.

    FCC Compliance for Class B Equipment

    The Central Control Unit (CCU) generates and may radiate radio-frequency energy. If it isnot installed in accordance with Kathreins installation instructions, it may cause inter-ference with radio and television reception. I has been tested and found to comply withthe limits for a Class B digital device in accordance with the specifications in part 15 ofthe FCC rules. These specifications are designed to provide reasonable protectionagainst such interference in a residential installation. However, there is no guarantee thatinterference will not occur in a particular installation.

    You can determine whether your equipment is causing interference by turning it off. Ifthe interference stops, the equipment you turned off was probably causing the interfer-ence. If the equipment causes interference to radio or television reception, try to correctthe interference by using one or more of the following measures:

    - Turn the television or radio antenna until the interferences stops.

    - Move the equipment to one side or the other of the television or radio.

    - Move the equipment farther away from the television or radio.

    - Plug the equipment into an outlet that is on a different circuit from the television orradio. (That is, make certain the equipment and the television or radio are on circuitscontrolled by different circuit breakers or fuses.)

    Modifications to this product not authorized by KATHREIN-Werke KG could void the FCCapproval and negate your authority to operate the product.

    CE Marking

    The CCU is CE accredited and thus in compliance with the essential requirements of theEuropean Regulations 89/336 EWG, electromagnetic compatibility, and 73/23/ EWG, lowvoltage directive.

    NOTICE

    NOTICE

  • 8/3/2019 RET Installation 9362371b

    8/32

  • 8/3/2019 RET Installation 9362371b

    9/32

    1. RET-System Overview

    9

    1.3 System Components

    1.3.1 Remote Control Unit (RCU)

    1) Tightning torque for fixing the connector must lie between 0.5-1 Nm.

  • 8/3/2019 RET Installation 9362371b

    10/32

    1. RET-System Overview

    10

    1.3.2 Central Control Unit (CCU)

    1) Tightning torque for fixing the connector must lie between 0.5-1 Nm.*) HU = Height Unit

  • 8/3/2019 RET Installation 9362371b

    11/32

    1. RET-System Overview

    11

    CCU Connectors

    Alarm Inter-face

    Open Collector

    RS232 Ethernet RCU inter-faces in accor-

    dance withAISG

    DC power supply48 V

    AC power supply100-240V(optional)

    Alarm Interface

    The Alarm Interface is provided by 8 open collector outputs. Eachoutput is user programmable. Please refer to the CCUs SoftwareManual on how to program the alarm interface.

    The Alarm Interface is offered via a 9-Pin female Sub-D connector.Pin 1 to pin 8 represent the 8 open collector outputs. Pin 9 is con-nected to the devices ground.

    The current through each output is limited by a current limiter to amaximum of 30 mA. The maximum voltage of an output shall not ex-ceed 6 V. It is recommended to use the standard TTL level for signal-ling an error on the Alarm Interface.

    All outputs of the alarm interface are not protected against over-voltage. If an inductance, e.g. a relay, should be switched theuser has to make sure to connect an external protection circuitlike a self-induction recuperation diode.

    NOTICE

  • 8/3/2019 RET Installation 9362371b

    12/32

    1. RET-System Overview

    12

    1.3.3 Connection Cables

  • 8/3/2019 RET Installation 9362371b

    13/32

    1. RET-System Overview

    13

    1.3.4 Splitter for DC Power and Signal

    1) Tightning torque for fixing the connector must lie between 0.5-1 Nm.

  • 8/3/2019 RET Installation 9362371b

    14/32

    1. RET-System Overview

    14

    1.3.5 Lightning Protection Device

    1) Tightning torque for fixing the connector must lie between 0.5-1 Nm.

  • 8/3/2019 RET Installation 9362371b

    15/32

  • 8/3/2019 RET Installation 9362371b

    16/32

    1. RET-System Overview

    16

    DTMA-UMTS-24-AISGFullband Double Dual Duplex Tower Mounted Amplifier(Masthead Amplifier)

    * The DTMA is not designed for permanent operation under water.

    Test conditions for the IP67 rating: submerge depth: 1 m; submerge time: 24 hours1) Tightning torque for fixing the connector must lie between 0.5-1 Nm.

  • 8/3/2019 RET Installation 9362371b

    17/32

    1. RET-System Overview

    17

    1.3.7 Smart Bias Tee (800 2170 MHz)

    1) Tightning torque for fixing the connector must lie between 0.5-1 Nm.

  • 8/3/2019 RET Installation 9362371b

    18/32

    1. RET-System Overview

    18

    1.4 RET System Control

    The major component for controlling the RCU is the Central ControlUnit (CCU), which is located at the BTS.

    In order to cover all required applications, the CCU can be accessedvia Ethernet or RS 232 interface. For example, access can thereby beachieved from WAN/LAN networks (TCP/IP) or directly on site bymeans of a personal computer (PC).

    The following transport and application protocols are served by theCCU: TCP/IP, PPP, UDP, DHCP, HTTP/HTML, ICMP/Ping, FTP andSNMP.

    The overall connection of the RCUs to one CCU can be effected viaseparate control cables (1).

    It is also possible to connect RCUs and CCU via feeder cable by us-ing Smart Bias Tees (SBT). One SBT is mounted near the BTS for bi-asing the RCU and to convert the control Signal to a modulated carriersignal. A second SBT is mounted near the antenna to extract the DC

    voltage and control signal from the feeder line (2).

    An elegant way of controlling the RET system is to combine aKathrein TMA and a RCU. Both the control signal and DC power sup-ply are fed onto the RF cable via Smart Bias Tee.The TMA includes a Smart Bias Tee function and takes these signalsand voltage from the feeder cable and forwards them to the connectedRCUs (3). (1) (2) (3)

  • 8/3/2019 RET Installation 9362371b

    19/32

    2. Installation Instructions

    19

    2. Installation Instructions

    2.1 Attachment of RCU

    General description of the interface (protective cap removed):

    Attaching the RCU (Remote Control Unit) for remotely-controlled downtilt adjustment:

  • 8/3/2019 RET Installation 9362371b

    20/32

    2. Installation Instructions

    20

    It is very important to keep written records that match up the serialnumber for each Remote Control Unit (RCU) with the antenna loca-tion (sector, position, frequency band) that it will be attached to.Remember that dual or triple band antennas can have more thanone RCU attached. The written records will be used for program-ming the Central Control Unit (CCU) after the equipment is in-stalled.

    RCUs should be attached to the antenna only after the antenna isrigged on the tower and the feedlines have been installed. This al-lows for proper torquing of the feedline connectors and preventsdamage to the RCU while the antenna is being hoisted up thetower.

    The bottom end-cap of each antenna has a label showing locations

    of the connectors (+/- 45 ports) and for dual and triple band an-tennas, the positions of the tilt adjuster mechanism for each band.

    2.2 Control Cable Installation

    Install the control cable according to the installation manual of the respective operator.

    RET system Control Cables must be properly dressed on towerto provide strain relief for the connectors and prevent damagefrom ice loading or repeated flexing caused by windy conditions.

    There is one Male connector and one Female connector on eachRET Control Cable. BE SURE TO INSTALL THE CABLES SOTHAT THE FEMALE CONNECTOR IS AT THE TOP OF THETOWER.

    NOTICE

    NOTICE

    NOTICE

    NOTICE

    NOTICE

    Tightning torque for fixingthe connector must liebetween 0.5-1 Nm.*

  • 8/3/2019 RET Installation 9362371b

    21/32

  • 8/3/2019 RET Installation 9362371b

    22/32

    2. Installation Instructions

    22

    2.4 Installation/Operation of the RET-System

    Before installing the RET System, carry out the following:

    It is recommended to document the results separately as you willneed this information to configure the RET System.

    - Determine the connected antenna types

    - Match the serial numbers of the RCUs which will be con-nected to the respective antennas

    - Determine the RCU arrangement in the different sectors

    Connect the RCUs to the respective antenna (follow instructionsunder section Attachment of RCU).

    Install, if required, other RET components such as Splitter, Con-trol Cable and/or LPD.

    Put the CCU into the designated rack. Both, horizontal or verticalinstallation is possible.

    The installation of the equipment is confined to Restricted AccessLocations (RAL).The CCU is only suitable for indoor use!

    Increased Ambient Operating Temperature:

    If the equipment is installed in a closed or multi-unit rack assem-bly, the operating temperature of the rack environment may behigher than the ambient room temperature. Therefore, install theequipment in an environment where the maximum ambient tem-perature limit (TMA) specified in the individual data sheets is pro-vided.Heat accumulation may otherwise occur and result in destructionof the device.

    Reduced Air Flow:If the equipment is to be installed on a rack, make sure that the airflow required for safe operation of the equipment is not impeded.Never install the CCU in a cabinet, shelf or rack with inadequate

    ventilation.Heat accumulation may otherwise occur and result in destructionof the device.

    Mechanical Loading:Mounting the equipment on a rack should be carried out in such away that no hazardous situation due to uneven mechanical loadingoccurs.Extraordinary operating conditions, such as heavy icing or excep-tional dynamic stress (e.g. strain caused by oscillating supportstructures), may result in the supporting structure, antenna or RETcomponent breaking, or even cause it to fall to the ground.

    Circuit Overloading:Mind the connection of the equipment to the supply circuit, andthe effect that overloading of the circuits might have on the over-current protection and the supply wiring.

    NOTICE

  • 8/3/2019 RET Installation 9362371b

    23/32

    2. Installation Instructions

    23

    Appropriate consideration of equipment nameplate and data sheetratings should be used when addressing this concern.

    Proper Earthing:Proper earthing of rack-mounted equipment should be maintained.Particular attention should be paid to supply connections otherthan direct connections to the branch circuit (e.g. use of power

    strips).

    The RET applications must be grounded according to the relevantlocal regulations!

    Connect the control cable(s) to the RCU interface at the CCUfront panel. (1)

    For the DC connection, please only use the enclosed connector.

    Check the polarity of the DC cable before you make the connec-tion.

    Make the connection between power supply and the DC interfaceat the CCU. The CCU is automatically operating after the CCUhas been connected to the power supply.

    If the CCU has an AC power plug, the CCU can also be poweredby AC power cable (3).The AC power supply has priority and switches off the DC powersupply automatically. The DC power supply can operate as abackup power supply.

    The power supply system of the CCU must be fuse protected.

    In case of AC powering, the nominal value of the breaking cur-rent must be less or equal to 20 Amps.

    In case of DC powering, the nominal value of the breaking cur-rent must be less or equal to 10 Amps.

    (6)Alarm

    Interface OC

    NOTICE

    (4)RS 232

    (5)Ethernet

    (7)LED Status

    (1)RCU interface

    in accordance withAISG

    (2)DC power

    supply -48V

    (3)AC power supply

    100-240 V(optional)

    NOTICE

  • 8/3/2019 RET Installation 9362371b

    24/32

    2. Installation Instructions

    24

    You can control the CCU either locally or remotely.

    To control the CCU locally, connect a PC to the CCU

    - by installing a null modem cable to the RS232 interface on theCCU (4) or

    - by installing a cross link cable to the Ethernet interface on theCCU (5)

    To control the CCU remotely, integrate the CCU into a networkby connecting a network cable to the Ethernet interface on theCCU (5).

    Details on configuration and controlling of the CCU are describedin a separate Central Control Unit Software Description, whichis delivered with each CCU.

    It is possible to transfer alarms, i.e. RET alarm, through the opencollector interface at the front panel of the CCU. (6)

    20 seconds after power on, the green LED on the front panel of theCCU is activated. (7)

    Continue with the instructions described in the Central ControlUnit Software Description, which is delivered with each CCU.If the red LED on the front panel of the CCU is activated, an errorhas occurred, i.e., the RCUs have not yet been calibrated or theconnection between RCU and CCU is interrupted. In this case,also follow the instructions described in the Central Control UnitSoftware Description in order to fix the error.

    Status LED:

    Green LED is switched on after power on and successful finishingthe booting procedure. If the green LED is not switched on after 20seconds, please check the polarity of power supply

    Red LED is switched on in case of any error states of the RET sys-tem.

    NOTICE

  • 8/3/2019 RET Installation 9362371b

    25/32

    3. RCU and CCU Connection Examples

    25

    3. RCU and CCU Connection Examples

    3.1 Overview

    Examples for RCU and CCU connection:

    1. Via Control Cable2. Via feeder cable utilising two Smart Bias Tees3. Via feeder cable utilising one Smart Bias Tee and one TMA

  • 8/3/2019 RET Installation 9362371b

    26/32

    3. RCU and CCU Connection Examples

    26

    3.2 In General

    The CCU delivers 13 V and 29 V power supply to the connected AISG devices.

    You can connect up to 27 RCUs to the CCU. Each CCU output supports up to nine RCUs if they arepowered by 13V. If the RCUs are powered by 29V you can distribute them to the CCU outputs asrequired by the system configuration. Each RCU can be identified and controlled individually via itsserial number.

    Due to power losses along the cables, there is an interrelationship between the number of the con-nected RCUs, TMAs and the maximum cable length.

    Each of the three CCU outputs is suitable for the connection of one TMA and up to nine RCUs

    3.3 Use of Control Cable

    The maximum control cable length (Lmax) depends on the type of RET configuration (see the examples inthis chapter).

    In star configuration with one control cable for each sector, the max. length of the control cable depends on

    the number of RCUs per sector (N_RCU/sector). In daisy-chain configuration, the max. length depends onthe total number of RCUs (n_RCU).

    The length values (29V) are listed in the tables below.

    Star configuration Daisy chain configurationN_RCU/sector L1max in m n_RCU Lmax in m

    1 220 1 280

    2 190 2 270

    3 170 3 260

    4 150 4 250

    5 130 5 240

    6 110 6 2307 100 7 220

    8 90 8 210

    9 90 9 200

    10 190

    11 180

    12 170

    13 170

    14 160

    15 150

    16 140

    17 140

    18 130

    19 13020 120

    21 120

    22 110

    23 110

    24 110

    25 100

    26 100

    27 100

  • 8/3/2019 RET Installation 9362371b

    27/32

    3. RCU and CCU Connection Examples

    27

    3.3.1 Connection of up to 3 RCUs

    3.3.2 Connection of up to 6 RCUs

  • 8/3/2019 RET Installation 9362371b

    28/32

    3. RCU and CCU Connection Examples

    28

    3.3.3 Connection of up to 9 RCUs

  • 8/3/2019 RET Installation 9362371b

    29/32

    3. RCU and CCU Connection Examples

    29

    3.4 Use of Smart Bias Tees

  • 8/3/2019 RET Installation 9362371b

    30/32

    3. RCU and CCU Connection Examples

    30

    3.5 Use of TMAs

  • 8/3/2019 RET Installation 9362371b

    31/32

    Abbreviation Index

    31

    4. Abbreviation Index

    AC Alternating Current

    AISG Antenna Interface Standards Group

    BTS Base Transceiver System

    CE Communaut Europenne

    CCU Central Control Unit

    DC Direct Current

    DHCP Dynamic Host Configuration Protocol

    DTMA Double Tower Mounted Amplifier

    ENV Europische Vornorm (European Pre-Standard)

    ETS European Telecommunication Standard

    EWG Europische Wirtschafts GemeinschaftFTP File Transfer Protocol

    HTML Hyper Text Markup Language based on HTTP

    HTTP Hyper Text Transfer Protocol

    ISB Idle State Biasing

    ICMP Internet Control Message Protocol

    LPZ Lightning Protection Zone

    OMC Operational Maintenance Center

    PPP Point to Point Protocol

    RCU Remote Control Unit

    RET Remote Electrical Tilt

    SBT Smart Bias Tee

    SNMP Simple Network Management Protocol

    TCP/IP Transmission Control Protocol/Internet Protocol

    TMA Tower Mounted Amplifier

    UDP User Datagram ProtocolUMTS Universal Mobile Telecommunications System

    VDE Verband Deutscher Elektrotechniker (association of Germanelectrical engineering technicians)

  • 8/3/2019 RET Installation 9362371b

    32/32

    Contact Addresses

    936.2371/B/0605/ZWT-Technicalda

    tasubjecttochange!

    Contact Addresses

    For all sales inquiries:

    Fax (++49)(+8031)184-820

    E-Mail: [email protected]

    For technical information:

    Fax (++49)(+8031)184-973

    E-Mail: [email protected]