Resetting to factory defaultsFactory defaulting ruggedized products
D-5
To reset a ruggedized product to factory defaults, follow this procedure:
1. Disconnect any cable from the AP.
2. Disconnect power from the PoE injector.
3. Configure your computer LAN port with a static IP address of 192.168.1.2 and a subnet mask of 255.255.255.0.
4. Use a Cat 5 Ethernet crossover cable to connect your computer LAN port directly to the PoE injector Data In port.
5. Connect a Cat 5 Ethernet cable from the PoE injector Data and Power Out port directly to the AP.
6. Open a command line session on the computer.
7. In the folder containing the script, specify the script name including its language identifier and the factory parameter like this:MSMRemote-en factory
Press Enter to execute the script.
8. Power on the PoE injector. The script performs the reset and confirms success with a message like this:Your "R" product has been successfully factory reset!
9. Once the factory reset completes, perform the procedure found in the Initial software