REQUEST FOR PROPOSAL (RFP)
for
Software Implementation of
Oracle Customer Care & Billing (CC&B)
Metered Work and Asset Management
Customer Self Service
Mobile Workforce Management
For Greenville Utilities Commission
RFP Number: 14-06
Key Proposal Dates
OFFERORS’ NOTICE OF INTENT TO RESPOND: MARCH 10, 2014 MANDATORY OFFERORS’ CONFERENCE: MARCH 11, 2014; 1:00 – 2:00 EASTERN
PROPOSAL DUE DATE AND TIME: APRIL 2, 2014; 4:00PM EASTERN ORAL PRESENTATIONS FOR SELECTED RESPONDERS: APRIL 29 – MAY 2, 2014
Confidential Page 2 2/27/2014
1 Contents
1 General Introduction ________________________________________________ 6
1.1 Introduction ___________________________________________________________ 6
1.2 Company Background __________________________________________________ 7
1.3 Project Background _____________________________________________________ 7
1.4 Notice to all Recipients of this RFP _________________________________________ 9
1.5 Copyright _____________________________________________________________ 9
1.6 Minority Business Participation Program ___________________________________ 10
1.7 Good Faith Statement __________________________________________________ 10
1.8 Preparation Of Proposal ________________________________________________ 10
1.9 Proposal Withdrawal ___________________________________________________ 10
1.10 Governing Laws And Adminstrative Code __________________________________ 10
2 Proposal Information ______________________________________________ 11
2.1 Table of Key Proposal Dates ____________________________________________ 11
2.2 General Instructions and Submission Requirements __________________________ 13
2.3 Proposal Manager and Contact with GUC __________________________________ 13
2.4 Ethics and Conduct of Offerors ___________________________________________ 14
2.5 RFP Submission ______________________________________________________ 14
2.6 Minimum Qualifications _________________________________________________ 15
2.7 Evaluation Criteria _____________________________________________________ 16
2.8 Choosing to Respond __________________________________________________ 16
2.9 Cost of Proposal ______________________________________________________ 17
2.10 Oral Presentations ____________________________________________________ 17
2.11 Company Rights ______________________________________________________ 17
Confidential Page 3 2/27/2014
2.12 Confidentiality ________________________________________________________ 17
2.13 Other General Information ______________________________________________ 18
2.14 Due Diligence ________________________________________________________ 19
2.15 Exceptions and Clarifications ____________________________________________ 19
3 Information and Guidance for Offerors ________________________________ 20
3.1 Current State Technology _______________________________________________ 20
3.1.1 Current CIS _______________________________________________ 20
3.1.2 Interfacing Systems/System Inventory __________________________ 21
3.1.3 Greenville Utilities ORACLE Application Infrastructure ______________ 21
3.1.4 User Authentication Requirement ______________________________ 22
3.1.5 ORACLE WAM Integrations (Engineering/ Outage /Mobile) __________ 22
3.1.6 Integration ________________________________________________ 23
3.1.7 System Objectives _________________________________________ 24
3.2 Project Management and Resources ______________________________________ 24
3.2.1 Program Organization _______________________________________ 24
3.2.2 Implementation Planning Guidance ____________________________ 26
3.2.3 Functional Area/Project Teams ________________________________ 27
3.2.4 Work Control ______________________________________________ 28
3.2.5 Work Schedule ____________________________________________ 29
3.2.6 Training __________________________________________________ 29
3.2.7 Change Control Process _____________________________________ 29
3.3 Scope of Work _______________________________________________________ 30
3.3.1 Methodology and Planning ___________________________________ 30
3.3.2 Scope by Suggested Project Methodology _______________________ 31
3.3.3 General __________________________________________________ 31
3.3.4 Software Configuration, Customization and Testing ________________ 32
3.3.5 Fit/Gap Analysis and Future State Business Process Flow Design ____ 33
3.3.6 Data Conversion ___________________________________________ 33
3.3.7 Interfaces ________________________________________________ 33
Confidential Page 4 2/27/2014
3.3.8 Training Plans _____________________________________________ 34
3.3.9 Roles and Responsibilities ___________________________________ 35
3.3.10 GUC Furnished Services ____________________________________ 36
3.3.11 Technical Documentation and Requirements _____________________ 37
4 SI Response Content and Format ____________________________________ 39
4.1 Executive Summary ___________________________________________________ 39
4.2 Qualifications and Experience ___________________________________________ 39
4.3 Methodology _________________________________________________________ 41
4.4 Project Plan __________________________________________________________ 42
4.5 Proposed Staffing _____________________________________________________ 44
4.6 Price Proposal ________________________________________________________ 46
4.7 Specified Agreement Concepts __________________________________________ 47
Confidential Page 5 2/27/2014
Under separate cover:
APP-A Functional Requirements – Functional requirements workbook. This list is
representative of the current requirements. GUC is expecting to work with the chosen
System Integrator during an analysis and functional design phase to determine how
these specific requirements will be included in the system design. This workbook
includes the following information:
o CIS Functional Requirements, including Customer Self Service
o “Metered” WAM Functional Requirements
o Mobile Workforce Management Requirements
APP-B To-Be Process Flows – GUC has completed work on an initial set of future state
process flows. These are being provided for informational purposes to help Offerors
scope the work. GUC is expecting to work with the chosen System Integrator during an
analysis and functional design phase to determine how these process flows will be
included in the system design.
APP-C GUC Interfaces – Current interface inventory
APP-D GUC Letters – Current letter inventory
APP-E GUC Metrics – Key metrics for certain business processes
APP-F Offeror Insurance Requirements – Minimum requirements the selected provider
will need to maintain
APP-G North Carolina E-Verify Statement – to be Completed by Offerors and Returned
to GUC
APP-H Certified Good Faith Statement – to be Completed by Offerors and Returned to
GUC
APP-I GUC Reports – Current reports inventory
APP-J Greenville-Logical-Physical-Architecture – Overview of current Oracle
environments
APP-K GUC System Diagram – GUC System Map
Pricing workbook – to be Completed by Offerors and Returned to GUC in Microsoft
Excel.xlsx Format (compatible with version 2010)
o SI Pricing.xls – System Integrator Pricing Workbook
Confidential Page 6 2/27/2014
1 General Introduction
1.1 Introduction
Greenville Utilities Commission (GUC) has chartered a program to Optimize Processes
and Technology to Improve Customer Service (OPTICS). This program modernizes
GUC’s information systems through the implementation of a suite of Oracle products.
The eBusiness Suite has already been implemented for Finance and Human
Resources. There is an ongoing initiative to implement Work and Asset Management
(WAM) for unmetered services. The next project under the OPTICS program is to
implement Oracle’s Customer Care & Billing (CC&B) solution, Customer Self Service
(CSS), Mobile Workforce Management (MWM) and the metered services within WAM.
GUC is considering two options for this implementation and asking for pricing on both.
Option 1: Full Scope. This includes CC&B, “metered” WAM, Mobile Workforce
Management (MWM), and Customer Self Service (CSS)
o The implementation of core ORACLE CC&B functionality and the establishment of core business logic for customer care and billing work, including Customer Self Service.
o The implementation of core ORACLE WAM functionality and the establishment of core business logic for enterprise management of assets and field work for customer and metered functions.
o The implementation of core ORACLE MWM functionality and the establishment of core business logic for mobile workforce management work.
o The integration of processes, data, and related systems between the above components, including implementation of the Field Work Process Integration Pack (PIP) and the productized integration between CC&B and e-Business Suite (EBS) (collectively, the “Integration”).
Option 2: Partial Scope. This includes CC&B and “metered” WAM.
o The implementation of core ORACLE CC&B functionality and the establishment of core business logic for customer care and billing work, including Customer Self Service.
o The implementation of core ORACLE WAM functionality and the establishment of core business logic for enterprise management of assets and field work for customer and metered functions.
o The integration of processes, data, and related systems between the above components, including implementation of the Field Work Process Integration Pack (PIP) and the productized integration between CC&B and e-Business Suite (EBS) (collectively, the “Integration”).
Confidential Page 7 2/27/2014
The requirements for the four scope components are defined in APP-A.
The purpose of this Request for Proposal (RFP) is to provide the requirements and
guidelines that will be used to select a System Integrator (SI) to assist GUC in this
implementation. GUC is seeking an experienced System Integrator to assist with the
integration and implementation of this solution into the overall GUC system landscape.
GUC encourages qualified RFP recipients, who can provide full system integration
services for the listed scope, to respond with details on their services and project
approach. GUC will only consider proposals from implementers that will
implement the full scope of the software indicated in this RFP. Offerors
submitting bids for less than the total scope contained in this RFP will not be
considered. GUC understands that this approach may result in the Offerors use of
subcontractors. Offerors are asked to carefully read the contents of this RFP for what
information must be communicated about subcontractors to GUC.
Proposals should include all costs as they relate to professional services, travel, and
any other expenses associated with the Offeror’s proposal.
1.2 Company Background
GUC provides electric, water, wastewater and natural gas services to the City of
Greenville encompassing 75% of Pitt County and serves a combined total of more than
135,800 customer connections. In addition, GUC provides billing and collection for other
municipal entities. GUC is a municipally-owned utility and operates under a separate
charter issued by the N.C. General Assembly.
GUC is guided and managed by an eight-member Board of Commissioners. The Board
is responsible for approving rates, strategic plans, the annual budget and setting
operating and extension policies.
1.3 Project Background
As noted above, GUC has chartered a program to Optimize Technology and Processes
to Improve Customer Service (OPTICS). This program modernizes GUC’s information
systems through the implementation of a suite of Oracle products. OPTICS has three
primary phases:
Confidential Page 8 2/27/2014
1. Cornerstone: This covers the implementation of Finance and HR-related
solutions. Oracle’s eBusiness Suite for Finance and Human Resources was
implemented in July 2013.
2. Synergy: This is an ongoing initiative to implement Work and Asset Management
(WAM) for unmetered services, which is scheduled for production deployment in
the fall of 2014.
3. Navigate: This is the project to implement Oracle’s Customer Care & Billing
(CC&B) solution, Customer Self Service, Mobile Work Force Management and
the metered services within WAM.
The primary drivers for change in Customer Service (CS) are related to two key factors:
1. Inability to perform CS functions (meter to cash) in alignment with customer
expectations (one-stop shopping, visibility into the full lifecycle of the customer
experience, etc.).
2. Current system is beyond end-of-life.
Replacement of the current CIS application is motivated by the need for an architecture
that will support future operational needs and customer expectations. When E-
CIS/Orcom was implemented in 1999 it was a contemporary solution. However, over
time, vendor investment in this software system has failed to keep pace with the market
for CIS software. Additionally, GUC’s business has expanded to include services to
other regional accounts, which requires a more flexible customer information system
than the current Orcom system.
GUC’s expectation is that meter inventory will be maintained within CC&B and that
CC&B will integrate meter-related service orders/field activities with WAM to allow work
for field and service crews to receive and manage their work from the WAM system.
This is what is meant by “metered WAM” or “WAM for metered services.” The integrator
for this project should assume that WAM for non-metered services will be fully
configured prior to starting the Navigate project.
The project objectives include:
Confidential Page 9 2/27/2014
Support the stated goal of GUC to optimize technology and processes to improve
customer service
Minimize customizations, maintain maximum software vendor maintenance
coverage over deployed software
Provide for a tight integration of the software footprint at GUC
Plan for and support Business Transformation Management through needs
assessment, communication campaigns, training, focus groups, etc.
Documented processes including process maps
Identify those business processes that need to be analyzed to reduce cost
Use information technology systems to build institutional knowledge and
automation of workflow processes
Support the strategic vision, mission, and business objectives
Solution addresses and supports all regulatory compliance
Establish adequate application design controls and ensure business rules are
documented as living requirements
Provide for knowledge transfer to GUC technical employees so that GUC can
leverage the capabilities of the installed solution and provide for the long term
technical support of the system.
Provide for knowledge transfer to GUC functional employees so that GUC can
leverage the capabilities of the installed solution and provide for the long term
functional support of the system.
1.4 Notice to all Recipients of this RFP
Neither submission by GUC nor your acceptance to respond to this RFP, in whole or in
part, constitutes acceptance by GUC of any contractual terms contained in your
response, if any, and shall not form a binding agreement between the parties. Such an
agreement shall only exist upon the execution of a mutually acceptable contract by both
parties. Except as otherwise set forth in such a contract, GUC makes no
representations or warranties to bidders.
1.5 Copyright
This entire document is considered protected in favor of GUC by copyright according to
US law. The contents of this document, including annexes and additions thereto, are the
intellectual property of GUC. No part of it may be reproduced or retransmitted in any form
or means without the prior written permission of GUC, which may be withheld in GUC’s
sole discretion.
Confidential Page 10 2/27/2014
1.6 Minority Business Participation Program
GUC has adopted an Affirmative Action and Minority and Women Business Enterprise
Plan (M/WBE) Program. Firms submitting a proposal are attesting that they also have
taken affirmative action to ensure equality of opportunity in all aspects of employment,
and to utilize M/WBE suppliers of materials and/or labor.
1.7 Good Faith Statement
All information provided by GUC in this RFP is offered in good faith. Individual item(s) are
subject to change at any time. GUC makes no certification that any item(s) are without
error. GUC is not responsible or liable for any use of the information or for any asserted
claims.
1.8 Preparation Of Proposal
Proposals must be in envelopes clearly marked on the outside with the name of the
proposal and the proposal due date and time. Proposals shall be addressed to:
Greenville Utilities Commission
ATTENTION: Purchasing Department, Cleve Haddock, Buyer II
401 S. Greene Street
Greenville, North Carolina 27834
1.9 Proposal Withdrawal
A proposer must notify GUC in writing of its request to withdraw a proposal within
seventy-two (72) hours after the proposal opening, not including Saturdays, Sundays, or
holidays. In order to justify withdrawal, the bidder must demonstrate that a substantial
error exists and that the proposal was submitted in good faith.
1.10 Governing Laws And Adminstrative Code
All contracts, transactions, agreements, etc., are made under and shall be governed by
and construed in accordance with the laws of the State of North Carolina. Bids,
proposals, and awards are subject to applicable provisions of the North Carolina
Administrative Code.
Confidential Page 11 2/27/2014
2 Proposal Information
Proposal Title: OPTICS Software Implementation
GUC RFP Number: 14-06
An Offerors’ conference call will be held on March 11, 2014 by GUC for all organizations
that will be responding to this RFP. This conference is scheduled from 1:00 PM – 2:00
PM Eastern Time. Attendance at this conference is mandatory for all Offerors.
2.1 Table of Key Proposal Dates
Item/Action Mandatory for
Responding
Offerors
Date
RFP Release Date No February 27, 2014
Offerors’ Notice of Intent
via email to Proposal Manager
Yes March 10, 2014, 4:00
PM Eastern
Offerors’ Conference
Overview and Q&A Session
Conference Bridge: 1-800-356-8278
Passcode: 758622
Yes March 11, 2014, 1:00 –
2:00 PM Eastern
Offerors’ Written Questions No March 19, 2014, 4:00
PM Eastern
GUC Written Response to Questions No March 24, 2014
Proposal Due Date
via FTP submission; hard copy responses
to follow within 2 business days
Yes April 2, 2014, 4:00 PM
Eastern
Oral Presentation Agenda to Selected
Offerors
No April 15, 2014
Selected Offerors Oral Presentations Yes April 29 – May 2, 2014
Confidential Page 12 2/27/2014
Item/Action Mandatory for
Responding
Offerors
Date
Held at GUC’s offices in Greenville, NC
GUC reserves the right to adjust any of the RFP key dates. If the dates are adjusted, all
Offerors who received a copy of the RFP from the Proposal Manager will be notified in
writing.
Any prospective Offeror failing to meet any milestone without prior notification and
consent of GUC will constitute cause for disqualification. The response format described
later in this RFP is mandatory. All formatting, outline numbering, specific explanations,
and examples must adhere to and match the GUC response format.
Confidential Page 13 2/27/2014
2.2 General Instructions and Submission Requirements
This section contains information on contact with GUC, assembling the RFP, content,
revisions, communications, presentations, interviews, proposal preparation costs,
proposal submission and company rights.
2.3 Proposal Manager and Contact with GUC
All communication/information should be channeled through the Proposal Manager listed below.
Proposal Manager: Cleve Haddock
Title: Buyer II
Mailing Address: Greenville Utilities Commission
401 S. Greene Street
Greenville, N.C. 27834
Email: [email protected]
Please submit all questions by email and limit communication related to this RFP
to the Proposal Manager.
Guidelines for contacting GUC during the RFP process and proposals:
1. If your organization might have any conflict of interest, including employment of an
immediate family member or in-law of a GUC employee, contact the Proposal
Manager immediately for resolution.
2. After receipt of the RFP, no Offeror can contact any employee or consultant working
on this RFP on behalf of GUC other than the Proposal Manager. No GUC employee
or consultant working on this RFP may discuss the RFP with any Offeror without
written permission from the Proposal Manager. Failure to adhere to this policy may
result in disqualification of the Offeror’s bid.
3. Any contact from Offerors via email must be sent to the Proposal Manager.
4. If you are unclear about the RFP prior to the Offerors’ Conference, send questions to
the Proposal Manager by email.
5. GUC will conduct an Offerors’ conference to answer general questions about
philosophies, strategies, policies, procedures, and requirements.
6. Once a selection is made by GUC, the successful Offeror will work with project
managers and functional team leaders as assigned by GUC.
7. Questions about the RFP
Confidential Page 14 2/27/2014
All questions should be submitted to the Proposal Manager via email only, no exceptions.
GUC will compile questions and send written responses via email to all Offerors
who have submitted their intent and attended the Offeror’s conference.
2.4 Ethics and Conduct of Offerors
By signing the proposal, the Offeror certifies this proposal is made in good faith and
without collusion or connection with any other person responding on the proposal. It is
also certified that this proposal is made in good faith and without collusion or connection
with any GUC employee(s). Finally, it is also certified that this proposal is made without
outside control, fraud, or other illegal or unethical actions.
The conduct of Offerors during this RFP and evaluation period will play a part in the
evaluation of the proposed solutions. Instructions to Offerors within the RFP are
expected to be followed and any contravention will be considered in assessing the
Offeror’s professional attitude in this respect.
2.5 RFP Submission
All Proposals must reference the Proposal title and GUC RFP Number noted on the title
page.
Submit one (1) electronic copy of the entire Proposal to the Proposal Manager by
FTP site by the Proposal due date and time.
Submit five (5) paper copies of the complete Proposal including pricing
information. The paper copies may follow the electronic submission within 1-2
business days. Front and back printing is preferred but not required. If file
attachments are embedded within the electronic submission, be sure that the
printed copies include all embedded files.
Requirement sections, pricing forms and response forms have been provided as
separate Excel and Word documents to facilitate Offeror responses. Offerors are
expected to respond within the document formats provided (compatible with
Microsoft Word and Excel 2010).
GUC reserves the right during the evaluation and selection process to review all
responses of Offerors and pursue multiple Offerors that best meet the needs of GUC.
Emphasis should be placed on conformance to the RFP instructions and templates,
responsiveness to requirements, and completeness and clarity of content. Elaborate
Proposals are neither necessary nor desirable. If the Offeror’s Proposal is presented in
Confidential Page 15 2/27/2014
a fashion that makes evaluation difficult or overly time-consuming, points will be lost in
the evaluation process.
Each proposal page should be numbered for ease of reference and should include
index tabs denoting each section.
Proposals should include responses to all items listed in section 4. Each proposal
response must explicitly reference the corresponding RFP section number. Proposals
that do not address these questions risk being disqualified.
All materials submitted with the proposal become the property of GUC and may be
returned only at GUC’s option. GUC has the right to use any or all ideas presented in
any proposal. Selection or rejection of the proposal does not affect this right.
Proposals that arrive late may be rejected.
2.6 Minimum Qualifications
GUC is inviting qualified SIs to bid on this RFP. Minimum SI qualifications are:
The implementation SI must be either a certified United States entity
Implementation Partner of Oracle or the software vendor.
The SI must assume responsibility as prime contractor for the contract.
Subcontracting is allowed for this RFP, subject to the prior written
approval of GUC and the provisions set forth in this RFP. Proposed
subcontractors must be clearly identified in the Proposal.
The SI must have acted as the prime contractor on a successful
implementation of CC&B for a United States utility, preferably a multi-utility
with services in electric, natural gas, wastewater or water. They must
also have implementation experience with WAM and the Field Work
Process Integration Pack.
The SI must be able to provide certified consultants experienced in the
proposed methodology, or equivalently qualified and experienced in a
comparable alternate implementation methodology.
The SI must be able to provide consultants certified and experienced in
the utility sector implementation of the Solution Set software.
Confidential Page 16 2/27/2014
Offeror must provide a price for a payment and performance bond in the
pricing workbook (SI Pricing.xls) in the appropriate line.
2.7 Evaluation Criteria
GUC will conduct a comprehensive, fair and impartial evaluation of all Proposals
received in response to this RFP.
GUC will award this Project based on an evaluation of how well each Offeror meets the
evaluation criteria listed herein. The criteria will be applied based on the information
contained in the response submitted by each Offeror and for those selected to provide
an oral presentation. Therefore, it is in the best interest of Offerors to provide
informative, concise, well-organized technical and business information relative to this
Project.
Evaluation criteria will include the following:
Qualifications and experience of Offeror and proposed assigned personnel
Experience in conducting similar projects for organizations of similar type
and size in the utility space
Methodology and Implementation Plan
Cost to GUC of the proposed solution, both the initial project cost and
costs throughout the life of the project
Financial stability/Risk Assessment of the Offeror
Completeness of Proposal
All proposals will be reviewed by GUC to determine if they contain the minimum
essential requirements outlined in the RFP, including instructions governing submission
and format and compliance with standard GUC requirements. Those proposals deemed
non-responsive may be disqualified without further evaluation.
2.8 Choosing to Respond
Should you elect to respond to this RFP, please inform the GUC Proposal Manager of
your intent via email by March 10, 2014. Upon receiving your response, you will be
supplied with a offeror ID to use for identification during the Offerors’ Conference.
Confidential Page 17 2/27/2014
2.9 Cost of Proposal
All of the costs related to the preparation and submission of a Proposal, including,
without limitation, the attendance at any oral presentations, personnel interviews and/or
any site visits, will be borne by the Offeror.
2.10 Oral Presentations
Subsequent to GUC’s preliminary review and evaluation of the submitted Proposals
GUC may, but is not required to, invite one or more Offerors to make presentations or
participate in interviews. For those Offerors who are invited, attendance will be
mandatory. Therefore, Offerors are encouraged to “save the date” for the presentations
and interviews which are anticipated to be held the week of April 29 – May 2, 2014.
Offerors who are selected to participate in the presentation and interview process will be
informed regarding the location, date and time.
2.11 Company Rights
This RFP does not commit GUC to award in response to this RFP. GUC reserves the
right to reject any or all Proposals, in whole or in part, and at its discretion, to cancel or
amend this RFP at any time. GUC also reserves the right to unbundle the deliverables
and contract with one or more Offerors for the production of one or more of the
deliverables.
By submitting a Proposal in response to this RFP, the Offeror grants to GUC the right to
contact or arrange a visit in person with any or all of the Offeror’s clients, whether or not
identified as a reference by Offeror.
The Offeror shall refrain from any publicity regarding this RFP, the contents hereof or
Offeror’s submission of a Proposal. The Offeror shall not release any information to
newspapers, magazines, journals or any other medium, about the acceptance of the
Proposal or the award of the contract without the prior written approval of GUC, which
GUC may withhold in its sole discretion.
2.12 Confidentiality
The existence and contents of this RFP are confidential and must be treated as such by
recipients. Recipients of this RFP may not use the information contained within this
RFP, nor disclose such information to anyone other than recipients’ employees who are
directly involved in preparing a Proposal in response to this RFP, without the prior
written consent of GUC. Recipients of this RFP are liable for all damages in case of
breach of confidentiality by recipient. The selected Offeror will be expected to sign a
confidentiality agreement upon award.
Confidential Page 18 2/27/2014
2.13 Other General Information
1. GUC expects to enter into negotiations with one or more of the Offerors determined
by GUC to be most able to meet the requirements as defined within this RFP.
2. Proposals should be based upon information supplied within this RFP; however
additional/alternative responses/information, if deemed appropriate by GUC, will be
considered and evaluated. Offerors are requested to list such responses/information
separately at the end of the RFP submission and clearly state any assumptions made
in the absence of GUC information.
3. The project team will evaluate the Proposals when all responses have been
received. All evaluations will be based on the contents of the written document. In
this stage no meetings or presentations with Offerors will be arranged. Offerors may
be contacted during this stage to clarify the content and meaning of details within
their respective Proposal.
4. Revisions to any Proposal before the final deadline must specify clearly in writing any
previous elements removed or new elements added.
5. The closing date for Proposals is April 2, 2014 at 4:00 PM Eastern. Responses
received after this time will not be considered unless an extension to the deadline
has been granted to all Offerors.
6. The evaluation, which will be carried out by GUC, will progress through the following
stages:
Receipt and review of proposals
Clarification of detail
Invitations to selected Offerors to participate in oral presentations
Offeror reference calls/visits
Negotiations and contracting At the end of the formal evaluation period, the project team will make its
recommendation to GUC’s executive leadership team. Offerors will be notified of the
outcome after this step has been completed.
7. All Proposals to this RFP hereafter referred become the property of GUC.
8. Proposals shall be valid for a minimum of 90 days following the proposal due date.
Confidential Page 19 2/27/2014
2.14 Due Diligence
This RFP is intended to provide enough information for Offerors to provide both creative
solutions and their best indicative pricing. GUC is providing Offerors with the opportunity
to ask questions both during the Offerors’ Conference and via email should Offerors
require any additional information to complete their response.
GUC further recognizes that Offerors will need a detailed due diligence effort prior to
final contract negotiations. The due diligence phase will be a collaborative effort
between GUC and selected Offerors. The due diligence phase will give the Offerors a
chance to ask questions in a greater level of detail than the RFP. GUC will determine
the timing, depth and logistics of the due diligence with the selected Offerors post RFP
response evaluation.
Offerors should include a copy of their proposed Due Diligence process with the RFP
response.
2.15 Exceptions and Clarifications
Offerors are requested to detail any exceptions to this RFP; provide exception detail
and reference the applicable section number. If there are no exceptions, provide a
statement indicating so.
Offerors may provide comments to clarify or expand its Proposal and/or to demonstrate
its understanding of the Request for Proposal.
Confidential Page 20 2/27/2014
3 Information and Guidance for Offerors
3.1 Current State Technology
3.1.1 Current CIS
GUC’s existing CIS is an Orcom system known as E-CIS, currently supported by
Vertex. The application and DB2 database run on an iSeries. The system was originally
installed in 1999. The system supports collections, credit, rates, billing, customer
information, service orders, meter reading, meter inventory, and customer contacts.
Storm water and refuse transactions are fed into the billing system from an outside
source but included on the GUC bill and collected by GUC. For some of our customers,
wastewater consumption is based off of a third party water usage which is fed into our
system. Customers can receive a paper bill, electronic notification or both for their
statements. Interfaces with E-CIS have been written in-house. See APP-C for expected
list of interfaces.
Electronic Bill Presentment and Payment was written by Utilities Solutions and their
subcontractors and is secured using Entrust. We allow: requests for services,
payments, bill view, usage graphs per meter and account information modifications. Self
Service Bill Payment options are: a onetime payment feature from customer bank
account and a link to the third party credit/debit card vendor. The web application
resides on a Windows server interfacing with the iSeries, the bill archive data used for
the bill view resides on a separate Windows server and is maintained with an in-house
application. These servers reside behind a reverse proxy server and firewall.
The Oracle software versions GUC expects to install are:
CC&B version 2.4, including:
Oracle Utilities Customer Care and Billing Base for Residential Customers
Oracle Utilities CC&B Credit and Collections for Residential Customers
Oracle Utilities CC&B Rating and Billing for Residential Customers
Oracle Utilities CC&B Rating and Billing for Interval Data for Res Customers
Oracle Utilities CC&B Cashiering for Residential Customers
Oracle Utilities CC&B Task Optimization Tools for Res Customers
Oracle Utilities CC&B Base for Commercial & Industrial Customers
Confidential Page 21 2/27/2014
Oracle Utilities CC&B Credit and Collections for C&I Customers
Oracle Utilities CC&B Rating and Billing for C & I Customers
Oracle Utilities CC&B Rating and Billing for C & I Customers for Interval
Oracle Utilities CC&B Cashiering for C & I Customers
Oracle Utilities CC&B Task Optimization Tools for C & I Customers
Oracle Utilities CC&B to Oracle EBSuite Financials for GL and AP
Micro Focus Net Express for CC&B (Mfr is Micro Focus International)
Micro Focus Server Express for CC&B (Mfr is Micro Focus International)
WAM version 1.9.1.1
GUC has also purchased 5 licenses of User Productivity Kit Professional, plus is
considering purchasing Oracle’s Customer Self-Service.
3.1.2 Interfacing Systems/System Inventory
GUC wishes to improve its business by replacing the aging software and business
processes with a process based solution thereby taking advantage of integrated
software, new technology, enhanced functionality, and creating an opportunity for
technology to help drive the business to further excellence. A high-level drawing of
GUC’s current major systems/applications is included as APP-K GUC System Diagram.
3.1.3 Greenville Utilities ORACLE Application Infrastructure
Greenville Utilities Commission (GUC) currently manages two datacenters that contain
Oracle systems. These two datacenters are designed to be as similar as possible. The
infrastructure for the ORACLE applications and databases consists of Cisco UCS, Cisco
Nexus switches and NetApp SAN storage. The USC environment is currently version
2.0(3a) utilizing all B22-M3 blade servers. In most cases these servers are configured
with a single 8-core CPU and 64 Gb of memory. The network utilizes Nexus 5500
series and 7900 Series switches utilizing FCoE and 10Gig Ethernet backbone with 1Gig
to the desktop. The NetApp storage is made of paired FC3070 controllers running in
version 7-mode with shelves containing fiber channel, SAS and SATA drive shelves.
Connections to this SAN consist of FCoE and iSCSI and are shared with the other
systems at GUC. The different ORACLE environments (DEV, staging/UAT,PROD)
have their own subnet, but do share one common iSCSI network for access to storage.
On top of this hardware, we are utilizing Oracle Linux operating systems within Oracle’s
virtualization Management. The only exceptions to virtual servers are the database
Confidential Page 22 2/27/2014
servers in production and staging/UAT. A PDF provided shows the logical design of the
Oracle environments. GUC is currently running version 11g R2 of the Oracle database
and Linux 5.9 operating system.
3.1.4 User Authentication Requirement
The Oracle Application and Database(s) tier for all instances will be installed in a non-
RAC deployment method. The Oracle Utilities Framework must leverage GUC’s existing
LDAP-complaint directory service, Active Directory for user provisioning and single sign-
on purposes. The intent is to have a person’s credentials from logging into their
workstation passed to the application. All user provisioning and any changes to the user
account must be done through Active Directory. We require that GUC staff be
automatically logged into the system from the Active Directory credentials that were
used to log into the workstation. If the person is logging in from a device that does not
have the Active Directory credentials, they should be prompted to enter them. It is also
required that permissions be setup with a role based security model.
3.1.5 ORACLE WAM Integrations (Engineering/ Outage /Mobile)
Mobile
Current WAM (v 1.9.1.1) integration is focused on exposing a REST/JSON based API to
support mobile application development. The API is built utilizing both existing ORACLE
WAM stored procedures and custom procedures. The API utilizes Ruby on Rails and
the Oracle Database driver to remotely execute stored procedures and future services.
A custom IOS library is utilized to connect to the REST/JSON API. The library utilizes
the RestKit library in additional to custom functionality. The application development is
heavily based on CocoaPods. CocoaPods is the dependency manager for Objective-C
projects. The CocoaPods framework is the basis for our organizations rapid application
development.
While future plans may include Android and HTML support, existing efforts are solely
focused on IOS mobile application development. The WAM Integration strategy outlines
potential future use of technologies such as node.js for specific application support
processes such as mobile push notifications, and application settings management.
Overall, the means by which the REST/JSON API and other supporting interfaces are
delivered will be scrutinized for applicability inside Oracle SOA and like technologies as
both the technology and organization mature in its use.
Engineering
Confidential Page 23 2/27/2014
In addition, the organization leverages GeoNexus and ESRI ArcGIS Server (v 10.1 sp1)
for its GIS to WAM integration. Specifically, the WAM System is planned for integration
to Schneider Electric’s Designer (v 10.1 sp1). This is a custom integration. The
Designer System supports the graphical design of infrastructure and is a critical system
in regards to managing the assets through its lifecycle. The main integrations between
Schneider Designer and Oracle WAM will focus on the work order task and the
inventory checkout.
Outage
Schneider’s outage management system Responder (v 10.1 sp1) is natively integrated
to the ESRI GIS system. A custom interface is proposed for the integration between
Responder and Oracle WAM, CC&B and MWM.
3.1.6 Integration
GUC prefers and supports service oriented architectures where possible. Service
oriented architectures offer us the best ability to re-package and reuse functionality from
any system as our needs change. GUC would also prefer that systems provide and
consume services as the mechanism for integration. A key component in the
implementation of this strategy is the use of Oracle's SOA Suite of technologies which
provide the platform for enablement of a Service Oriented Architecture.
GUC currently uses a standards-based, hot-pluggable middleware approach to system
integrations with Oracle’s SOA Suite(SOA) and Oracle’s Service Bus (OSB). The
current version is 11.1.1.6 for the Development, Staging, and Production environments.
All three environments are single instance. GUC operates with a single domain. We
have an Administration Server managing three standalone Managed Servers: SOA,
OSB, and BAM. We are also making use of Node Manager as a way to automatically
restart Managed Servers in the event of a failure and to allow Managed Server control
from the Administration Console.
GUC has purchased Oracle’s Field Work Process Integration Pack (PIP) to link the field
work and planning functions in Oracle Utilities Customer Care and Billing, Oracle
Utilities Mobile Workforce Management, and Oracle Utilities Work and Asset
Management. We expect the Integrator to use this component for integration when
applicable.
Interfaces currently in place or needed for GUC 3rd party applications are provided in
the accompanying document APP-C GUC Interfaces.
Confidential Page 24 2/27/2014
3.1.7 System Objectives
The Offeror must take advantage of the characteristics and features within the
application framework to retain:
Modular design
Standard interfaces
Pre-built common components and services
Component reusability
Reliability of components and operations for High Availability daily operations as
well as Disaster Recovery planning
Interoperable and standard components
Adherence to agreed upon standards
Secured sharing of information
Maximized use of existing resources while transitioning
3.2 Project Management and Resources
3.2.1 Program Organization
GUC recognizes the important partnership we are embarking on with the chosen SI.
GUC is dedicated to providing our most experienced resources throughout this
implementation effort. GUC wishes to be thoroughly involved throughout the process in
order to foster internal change advocates, knowledge transfer, and user buy-in.
The governance of this implementation is recognized as paramount to the successful
go-live within time, budget and quality constraints. GUC expects to use an overall PMO
group as oversight for the OPTICS program and to facilitate coordination across the
multiple project teams. At the project level, GUC will provide internal project
management leadership to mirror the SI project leadership. Each of the functional
areas will have a “Process Owner” covering a breadth of experience across that
operational area. Additional Subject Matter Experts (SMEs) are included as needed for
their specific expertise or to augment due to spikes in work load such as during testing,
training or rollout support. In order to foster cross area coordination, each project lead
is part of the Leadership Core Team along with the PMO for weekly pulse meetings. A
representative organization chart is included below, with the green boxes representing
the scope of this RFP.
Confidential Page 25 2/27/2014
Steering Committee
OPTICS Program Management
Cornerstone Project
Team 1
Synergy Project
Team 1
Navigate Project
Functional Team
Account Billing
Customer Service
Meters/ Devices
Tech Infrastructure
Development Team
Development Conversion
Change/ Training Team
Issues and Change Control Management governance would flow from the Process
Owners to the Project Lead to the Program Manager. Most issues and approvals
should be resolved at this core team level. If needed, issues would then escalate to the
Steering Committee. The Steering Committee is comprised of the Executive Sponsors
as well as other corporate executives in order to communicate status updates and key
decisions or milestones reached throughout the project.
The OPTICS program is nothing short of a business transformation effort at GUC. All
key business processes will be up for redesign. GUC will provide their current utility
business expertise and look to the chosen SI to provide knowledge of industry and
application best practices for guidance in designing and configuring these new
transformational processes.
GUC will provide dedicated project management resources during the engagement.
Our current resource commitment is as follows :
Program Manager (1) – 40%
Project Manager (1) – 100%
Confidential Page 26 2/27/2014
PMO/Organizational Change Management (1) – 100%
3.2.2 Implementation Planning Guidance
1. It is expected that the proposed project will start July 14, 2014.
2. GUC is open to leveraging the value and efficiencies of pre-configured solutions that
are relevant to the business processes and software being implemented.
3. GUC has an internal PMO and functional area project managers that will coordinate
the implementation plan, work and resources for GUC along with the SI’s program
and project managers. GUC will dedicate key full-time resources per functional area
to be involved throughout planning and implementation. GUC will also supplement
with part-time subject matter experts in functional areas as needed. GUC wishes to
work with the implementer throughout implementation in order to foster knowledge
transfer and be able to internally continue to support and configure the system post
implementation.
4. GUC has successfully utilized a pilot approach in the past as part of a quality-
assurance testing phase and feedback for change-management issues. Whenever
schedule time permits, walkthroughs with novice users will help to identify key
change-management issues and allow for time to address them in training materials
and project communication. We realize that the key to successful adoption of any
software solution will be the change management. Significant communication and
training campaigns will be needed throughout implementation to foster a smooth
rollout and system adoption.
5. GUC wants to minimize any customization. Our goal is to adopt standard practices
and only add the complexity and cost of customization if there is no other way to
handle a regulated requirement. We want to be able to minimize cost of the
implementation project and be able to upgrade software in the future with a minimum
of development rework and avoid the dependence on a large internal
support/programming staff.
6. Operational reporting will need to be in place before any roll out. Often times a
continued use of the old system and a delay in the acceptance can cause a distrust
in the new system. The implementer should factor in sufficient time to include
development of key operational reporting prior to go-live.
7. GUC is considering licensing automated testing software as part of the technology
stack licensing. The implementer should recommend the testing solution that best
fits the application Solution Set and a deployment of this size. In the past, GUC has
written test plan/script documents and manually executed the tests with sign-offs.
Confidential Page 27 2/27/2014
Please propose the appropriate level of either the development of automated testing
or manual processes throughout the Solution Set implementation effort.
8. GUC expects to use SharePoint for managing project documents, but is open to
using an Offeror-supplied repository/tool if it supplies additional value. If an Offeror-
hosted solution is proposed, GUC requires a full extract of data from the repository
upon project completion and the data must be in a readily accepted format for
viewing and editing.
9. GUC’s legacy database systems have long established fixed format data structures
with seemingly simplistic conversion requirements. However, as is common with
older systems, comment fields have become “multi-purpose” to accommodate ways
of adding information while trying to avoid significant system modifications. Although
this is not unusual for companies with 15-plus-year-old legacy applications, it should
be taken into account in the implementer’s estimates for data conversion.
10. GUC is open to vendor’s recommendation for data conversion. GUC’s CC&B core
team has analyzed the various approaches to data conversion and the initial thought
is that GUC would be agreeable to a “balance forward” conversion with 13 months of
historical data. Historical data includes the following areas – meter, usage, billing,
payment, and adjustments. At a minimum, enough data will be converted from the
current legacy system to:
o Allow collection activities to continue o Allow customers to view historical information via web o Allow customers to sign up for budget billing o Allow employees to have some historical data at finger tips, without having to
access the legacy system o Have little or no impact on the General Ledger o Have enough data to do year end, monthly, and quarterly reporting without
having to access two separate databases
3.2.3 Functional Area/Project Teams
The following is a detailed description of GUC resources and their areas of expertise
that GUC plans to dedicate to the implementation effort for each of the program areas.
It is assumed that these resources will be in use throughout the length of their
functional area’s implementation effort and assume their normal job roles soon
after Go-Live of their application modules. The SI should consider these levels of
involvement from GUC while making their implementation effort estimates and
completing the SI Pricing.xls workbook.
Confidential Page 28 2/27/2014
Navigate Project Team (10-14 FTE’s)
Functional Lead
Billing Process Owner
Financials Process Owner (AR, GL, & Collections)
Meters/Field Work Process Owner
Customer Service Process Owner (includes Credit/Revenue Protection)
Operations Process Owners/SMEs (included in overall functional team)
Organization Change/Training Lead
Development Lead, Developers
Data Conversion (Legacy) Lead
Technology Program Team (2-4 FTE’s)
Technology Team Lead
Application DBAs/System Administrators
Server Administrator
3.2.4 Work Control
Throughout the project the SI will attend weekly status meetings and employ
ongoing Project Management techniques to ensure a comprehensive project plan
is developed, monitored, and maintained.
The work plan submitted with the proposal will serve as the basis of the plan to
be used throughout the project. This draft plan is to be updated and submitted in
electronic and paper form to the GUC Project Manager as required.
The SI will be expected to maintain an up-to-date work plan of all project tasks,
activities and resources including estimated start and completion dates, actual
start and completion dates, estimated and actual task hours, and completion
percentage for all in-process tasks.
The SI shall not make any change to GUC’s current production environment
without explicit written permission.
All development objects shall be stored and controlled in GUC’s environment. SI
shall propose configuration management and version control processes to
control the to-be system.
The SI shall be responsible for reporting and obtaining approval from GUC to
proceed on any event that materially affects scope, schedule, cost, or quality.
Confidential Page 29 2/27/2014
3.2.5 Work Schedule
GUC projects the full Implementation to run between 1.5 and 2 years. This
projection can be adjusted based on input from the SI.
Normal hours of work are Monday through Friday 8:00 a.m. to 5:00 p.m. Eastern.
The SI shall not schedule any activity involving GUC personnel outside this
timeframe without prior GUC approval.
3.2.6 Training
GUC’s desired end user training approach is “Train the Trainer.” Key change advocates
within the organization are typically chosen to learn and test the system, they then in
turn, become the internal trainers and are augmented support during roll out.
GUC desires knowledge transfer to the project delivery team members throughout the
project lifecycle, including pre-phase delivery team training on the applications and the
Integrator’s delivery methodology as necessary.
3.2.7 Change Control Process
All issues will be expected to be logged during the project. Those which impact the
project schedule, budget or scope will need to be quantified. Low impact items should
be taken care of within that team’s leadership. Weekly pulse meetings with all Team
Leads can be used to report on outstanding issues and review actions/decisions made
from those low impact items. Change Control will pertain to those issues which are
deemed of higher impact. The tolerance levels of impact will need to be established by
the project team and approved by the GUC Program Manager at the beginning of the
project.
It is expected that each functional area team should have the ability to handle most of
the day to day decisions with the knowledge and authority of the Team Lead or Project
Manager. If the issue or change impacts other functional areas, or is above an
established tolerance, then the next level of escalation for review/approval should be to
the Project Managers. If the issue is of an even higher tolerance level which will
significantly impact the overall project budget or schedule it should then escalate to the
GUC Program Manager.
Each escalated issue which proposes a change to the project schedule, budget or
scope will need to be estimated and risk analysis completed prior to review and
approval. The establishment and use of a tool or templates will be critical to the
continued documentation and tracking of these issues throughout the life of the project.
Confidential Page 30 2/27/2014
3.3 Scope of Work
3.3.1 Methodology and Planning
The SI, with participation by GUC’s Program Manager, will develop and implement a
methodology and process. The SI will coordinate with GUC in designing, developing,
and implementing an effective Business Transformation Management Plan to adjust
work performance to the new business processes and the Solution Set software.
Expected milestones for the SI include the successful implementation of redesigned
business processes, ensuring staff readiness prior to go-live, demonstration of
comparable performance levels for production staff as compared to the current system
performance, and plans to minimize performance issues. As part of this work effort, the
SI will be responsible for producing the following:
A detailed Business Transformation Management Plan including an analysis of
the business impact of the “to be” processes
A detailed Risk Management Plan that includes:
1. Risk Identification
2. Qualitative Risk Analysis
3. Quantitative Risk Analysis
4. Risk Response Planning
5. Risk Monitoring and Control
An organizational alignment strategy mapping the new business processes to the
appropriate roles and responsibilities within GUC. This should define roles and
responsibilities in the new organization, and identify the positions or individuals
associated with each role. The organizational alignment strategy should also
discuss timelines, detailed steps for executing the strategy, and will be
incorporated into the Integrated Work Plan.
An Organizational Development Plan that addresses leadership readiness and
acceptance of new business processes and functions for front line staff.
Implementation strategy for the new roles and responsibilities defined in the
organizational alignment strategy and the associated “to be” processes.
Confidential Page 31 2/27/2014
3.3.2 Scope by Suggested Project Methodology
1. Planning: The purpose of this phase is to plan for the project and document all
project strategies and procedures. A critical deliverable is the project work plan. It is
expected that a final output of this phase is a full team kick-off meeting.
2. Analysis & Functional Design: The purpose of this phase is to create the solution
design, which is a detailed documentation of the results gathered during
requirements workshops/meetings. It will allow the implementation project team to
clearly define their scope and only focus on the processes needed to run the
business. This includes validating/defining all requirements and developing the
functional specs/detailed process flows.
3. Configuration & Development: This phase includes technical design,
configuration, development, preparing test plans, and unit testing.
4. Testing: This phase includes system testing, integration testing, and other forms of
system validation.
5. Transition: The purpose of this phase is to prepare the production environment,
conduct end user training, finalize the system configuration and databases, and
conduct final system functional and stress testing. It also includes go-live
contingency planning.
6. Production Support: This includes post-implementation support of the new system.
3.3.3 General
GUC has spent time documenting “To Be” business process flows, which are being
provided as part of this RFP in APP-B To-Be Process Flows. All requirements,
specifications and process maps for the “to-be” system shall have bidirectional
traceability to:
Individual
Department
Procedure
Regulation
Best Practice
Application Screen
Test Plans
Confidential Page 32 2/27/2014
Security, reports, forms, data needs, interface identification, unique configuration
points
All specification and requirement documents shall undergo verification and validation to
address quality attributes, to uncover inconsistencies and redundancies, and to verify all
technical requirements have been incorporated and that they are testable.
The SI shall work closely with GUC’s Information Technology organization for adhering
to existing standards. Where such standards do not exist, the SI must help institute new
standards or assist in modifications to existing standards.
Business Models should be produced that are reflective of existing suggested best
practices for utilities. SI should propose the toolset to be used for this purpose; process
mapping will be performed using the SI’s toolset, and the process maps produced shall
be left in an updateable format upon completion of the project. The Business Models
should provide for 4 views as follows:
Organization View
Data View
Control View
Function View
A Business Process Architecture should be produced that shows the following levels.
Level 1 Enterprise Map
Level 2 Process Area Maps
Level 3 Main Process Models
Level 4 Process Models
Level 5 Activity Models
3.3.4 Software Configuration, Customization and Testing
The SI will perform all necessary activities to:
Install and configure the Solution Set Software to GUC specifications.
Successfully deploy a baseline version of the Solution Set Software.
Confidential Page 33 2/27/2014
Produce documentation of the software configuration specifying the configuration
values within the system to support GUC business practices.
Deliver functional and technical design documentation for all customizations or
advanced configurations of the Solution Set Software.
Deliver a detailed System Test Plan for both functional and stress/load testing.
Offerors should assume that 40 custom reports/data exports will need to be
developed across the entire solution footprint. Offerors should also propose how
additional reports will be estimated and priced if required.
3.3.5 Fit/Gap Analysis and Future State Business Process Flow Design
The SI will perform a gap analysis to identify GUC’s requirements that are not
addressed by the Solution Set packages as delivered, and to recommend how these
gaps will be handled. If no solution exists, the SI will provide information sufficient to
allow integration with a third party solution or to otherwise provide for the custom
development of the same or similar functionality.
3.3.6 Data Conversion
The SI will be responsible for mapping all agreed upon legacy data from GUC legacy
systems into the newly configured and customized system(s). GUC will provide subject
matter experts to assist in conversion mapping activities and extraction of data from
GUC legacy systems. As part of this work effort, the SI will at a minimum:
Deliver a detailed Data Conversion Plan.
Produce documentation for all conversion programs and/or methods of
converting the required legacy data.
Design, develop, and test the data conversion process.
Manage and execute, with the assistance of GUC IT resources, the data
conversion process.
3.3.7 Interfaces
The SI will be responsible for ensuring that all required inbound and outbound interface
files are successfully produced, read and processed by the System. As part of this work
effort, the SI will produce, at a minimum:
Interface design documentation for all new or modified interface programs.
Design an interface architecture that is compliant with the GUC integration
architecture utilizing web services and real time interfaces whenever possible.
Confidential Page 34 2/27/2014
Develop a complete and thorough testing methodology of all inbound and
outbound interfaces to ensure accurate extraction of all data required for the
interface.
Develop and test the interfaces.
A detailed list of existing system interfaces are provided in APP-C GUC Interfaces. It is
expected that there will be consolidation of individual components during the
implementation projects.
3.3.8 Training Plans
The SI will design, create, and provide training plans for Project and GUC staff. As part
of this implementation effort, the SI will:
Produce a detailed training strategy including comprehensive course catalog that
lists all training classes required for the implementation project.
Produce a training strategy/process that ensures that all users are trained in their
roles prior to go-live. This training strategy/process should state whether the
approach to be used for training is a “train the trainer” approach or a “train
everyone” approach.
Produce as part of the training plan the detailed steps that will be used for
knowledge transfer to GUC technical personnel so that GUC can be self-
sustaining in the ongoing technical support of the installed solution.
Produce a detailed audience analysis identifying the types of users and their
associated training needs. The detailed audience analysis should also identify
the training delivery method best suited to each audience and the size of the
training effort.
Produce a comprehensive training curriculum and the associated logistical
support that will work in conjunction with the Master Schedule and ensure that
training has been completed for users prior to go-live.
Produce an evaluation process for all training courses which will ensure that
each course establishes the required skill level for the end user of the new
System and/or technical support of the System.
The training strategy shall include at a minimum:
A sustainable learning approach to refresh skills and meet needs of new users
Role-based learning curriculum
Confidential Page 35 2/27/2014
A method of validating that users have accessed and used the training sandbox
A method of validating role-based curriculum and schedules to ensure relevancy,
gain support and meet business needs
Providing end-users with a clear understanding of:
1. The purpose, importance, and benefits of adopting the Solution Set and
new business processes
2. The “To-Be” or future business processes taking into account Utility
industry standard practices
3. Role requirements (i.e., "who will do what") at go-live and beyond
4. How to use the system through hands-on exercises and access to a
sandbox
5. Integration across role and functional areas
6. The impact of their role on the process
7. How to find appropriate help
3.3.9 Roles and Responsibilities
The GUC Project Manager and Functional Area Team Leads will be responsible
for guiding overall project management.
The SI will be responsible for managing the day to day activities and tasks
necessary to complete each implementation phase.
The SI may wish to partner with specialist consultancy/service providers or
broker a team arrangement with subcontractors to accomplish the system
implementation. However, the SI as prime contractor shall retain responsibility for
delivery and performance.
The SI shall supply design, customization, documentation and implementation
planning for the Solution Set that meets the specific requirements contained in
this RFP.
The SI shall lead the design/planning workshops and document the high-level
process designs and decisions by participants.
Confidential Page 36 2/27/2014
The SI shall supply an implementation path and strategy to retire current
applications.
The SI will be responsible, with the assistance of GUC IT, for establishing at least
five system environments. These environments are: Development, Conversion,
Test, Training, and Production.
The SI shall ensure that the proposed design solution to the maximum extent
possible provides a path for the Solution Set enhancement packages and
upgrades.
The SI shall supply technical support to implement interfaces with mobile
computers, iPads, hand held devices, RFID, bar code, scanning and other
electronic monitoring equipment that may be integrated for use with the “to be”
solution.
The SI shall specify appropriate end user training and materials.
The SI shall supply complete integration planning, design and comprehensive
scope of work to implement all technologies and interfacing systems required to
support the Solution Set.
The SI will interface as necessary with the GUC management, members of the
project teams and Subject Matter Experts.
The SI shall provide experienced consultants with sufficient knowledge of the
proposed Solution Set such that the SI can suggest alternatives to custom
development and thereby maximize use of existing code.
The SI shall be responsible for training their own staff and subcontractors, GUC
shall not bear any costs associated with the training of the SI or SI subcontractor
staff.
3.3.10 GUC Furnished Services
GUC shall provide business expertise and resources.
GUC shall provide a work area.
GUC shall provide a secure Local Area Network access that allows VPN access
out of GUC’s network, and VPN access to GUC’s network.
If a GUC workstation or laptop is used, the workstation shall not be removed from
GUC.
Confidential Page 37 2/27/2014
GUC shall provide hardware to support all required environments.
GUC shall provide access to existing applications, as required to complete the
project.
3.3.11 Technical Documentation and Requirements
The following describes the minimal set of documentation to be provided by the SI
during the project. Additional documents based on the SI methodology are expected.
Document Description
Design Workshop Summary The workshop summary includes a comprehensive
listing of each workshop held by functional area and
the key objectives of the workshop.
To-Be Business Process
Maps
The Business Process maps identify the core set of
transactions for the baseline implementation of the
solution set. Throughout the phases, the project team
will adjust the maps as necessary when the solution
matures through the development lifecycle. The maps
from design serve as the starting point for transaction
identification and will also be used for identification of
training documentation, customization, interface,
conversion, security and testing materials.
Communication Plan
Risk Management Plan
Issue Management Plan
Scope Management Plan
Project Work Plan (MS
Project format)
Organization Change
Management Assessment
and Action Plan
Data Migration Plan Includes plans for Extraction, Transformation, Load,
Validation, and Balancing/Audit
Confidential Page 38 2/27/2014
Document Description
Development Procedures
and Conceptual Design of
Development
Includes
o System Design Standards
o Current application retirement plan
o Software Development Plan
o Alternatives to Custom Development
o Cost Projection for each Approved
customization
Security Requirements Includes
o Authorization Requirements and Design
o Portal User Management Concept
o Security Concept
o User Role Requirements
Technical Architecture
Design and Project
Installation
Includes
o Technical and Integration Design
o System Interface Design Document
o Form and Report Design
o Development Environment
o System Administration Procedures
o Portal User Interface Design and
Personalization Concept
o Mobile Device Management
o Support Procedures
o Hardware, Network, and Database
configurations
Confidential Page 39 2/27/2014
4 SI Response Content and Format
Emphasis should be placed on conformance to the RFP instructions and templates,
responsiveness to requirements, and completeness and clarity of content. Elaborate
proposals are neither necessary nor desirable. If the Offeror’s Proposal is presented in
a fashion that makes evaluation difficult or overly time-consuming, points will be lost in
the evaluation process. Each proposal page should be numbered for ease of reference.
Proposals should include responses to all items listed below. Each proposal response
must explicitly reference the corresponding RFP section number. Proposals that do not
address these questions risk being disqualified.
4.1 Executive Summary
The proposal must include an Executive Summary of the Offeror’s proposal. This
Executive Summary should concisely convey what the Offeror sees as the most
important messages of the proposal, the factors that differentiate the Offeror’s solution,
and the critical points for GUC to consider in its implementation. GUC expects the
Executive summary to be no longer than two pages.
4.2 Qualifications and Experience
The Offeror must include in its proposal a summary of its qualifications and experience,
including the following:
Company Information for Prime Contractor and each Subcontracted
organization
o Provide legal name of organization, address, telephone and fax numbers
o Provide name of primary contact, title, telephone number and email
address
o Type of organization (corporation, partnership, proprietorship or joint
venture)
o Date Offeror entity was founded
o Offeror’s corporate mission and vision statements
o The industry or regional focus that the firm’s services partnership is based
upon
Confidential Page 40 2/27/2014
o Provide audited Respondent’s financial statements for the past three
years
o Dun & Bradstreet numbers
References for Prime Contractor and each Subcontracted organization
o Provide at least three references from the United States, preferably utility
customers with a similar implementation as GUC.
o Additional references are to be provided for each subcontracted
organization that will add five or more resources to the project (“material
subcontractors”). These references should preferably be utility clients with
similar implementations as GUC. The references for subcontractors must
show the scope of work they provided for the referenced account, and it
should be similar to the scope of work the subcontractor is being proposed
to do at GUC.
o Reference information to be provided for the Prime contractor and each
material subcontractor should include:
Client name, type of utility (electric utility, natural gas distribution,
water, wastewater, etc.) and customer base
Contact name, title, address, telephone and email address
Prime contractor or subcontractor
Project details including duration (days), functional areas (modules
implemented by contractor), prime contractor or subcontractor’s
roles and installation date
Current product version in production
Performance / cost saving metrics (if available)
Certification
o Joint or combined proposals by firms or companies must be certified on
behalf of each participant by a responsible officer.
Other
o Provide any additional information about the Offeror’s experience and
qualifications to be the prime contractor for GUC including:
Confidential Page 41 2/27/2014
Historical implementation success in electric, natural gas, water,
and waste water utilities
Industry knowledge, experience and time since last implemented
4.3 Methodology
The Offeror must include in its proposal the following information regarding its proposed
methodology in providing services:
Describe the proposed duration and methodology for the Solution Set
implementation.
Project Management:
o Describe the critical factors for success for the proposed project.
o Describe the key performance indicators (KPI) the Offeror will use
to monitor the project. At a minimum, KPI’s shall address Scope,
Schedule, Budget, and Quality. Provide sample project reports.
o Describe the method of regaining schedule compliance should
slippage occur.
o Describe the Offeror’s scope control plan/process.
o Describe the methodology proposed for Risk Management.
o Identify and describe the methodology proposed for post-
implementation support.
o Describe the roles and responsibilities for both the SI and the GUC
personnel for the project. Include a detailed list of activities that the
GUC staff is expected to undertake.
Organizational Change Management:
o Describe the methodology proposed for Business Transformation
Management/Organizational Change Management.
Functional:
Confidential Page 42 2/27/2014
o Describe the methodology proposed for solution design. Be as
specific as possible on how GUC’s requirements will be
mapped/broken down into business processes, how business
processes will be covered in workshops, how a
sandbox/development system will or will not be used during design,
and what work products will be delivered by the end of design.
GUC is open to and interested in leveraging the value and
efficiencies of pre-configured solutions that are relevant to the
business processes and software being implemented. If proposing
a pre-configured or partially configured solution, please be specific
on the scope of the existing configuration, how it would be
leveraged during design, where the cost savings/efficiency gains
would be, the level of documentation included for the pre-
configured components, and how the use of pre-configured
components has been incorporated into the project timeline and/or
resource plan.
o Identify and describe the methodology proposed for system
configuration. Include significant inputs, process steps, and
outputs.
o Identify and describe the methodology proposed for software
testing. Include significant inputs, process steps, and outputs.
o Identify and describe the methodology proposed for staff training.
Include significant inputs, process steps, and outputs.
Technical
o Identify and describe the methodology proposed for development
(reports, interfaces, enhancements, letters, workflow). Include
significant inputs, process steps, and outputs.
o Identify and describe the methodology proposed for data
conversion. Include significant inputs, process steps, and outputs.
Provide a clear and thorough description of all assumptions made.
4.4 Project Plan
The Offeror must provide a preliminary Project Work Plan that describes the proposed
schedule of activities to be performed. The plan must indicate the proposed activities,
Confidential Page 43 2/27/2014
schedule and resource commitments of both GUC and the SI. The Plan must be
furnished in both hard copy and Microsoft Project format. In the event of a discrepancy,
the hard copy shall govern.
Provide the hierarchical outline (work breakdown structure) for major
activities included in the project. Work Breakdown Structure shall be to at
least Level 2: PMI's Practice Standard for Work Breakdown Structures.
Provide a Gantt chart representing key milestones, project activities, and
deliverables.
Describe the methods that were used to optimize the schedule.
Explain how the the work plan will be used to track progress of the project
and how progress is measured.
The methodology for data conversion (the “how”) should be described in
section 4.3. In this section, describe how that conversion methodology fits
within the proposed schedule of the overall project and project phases (the
“when”). Highlight significant predecessor activities, successor activities,
and stage gates.
The methodology for solution design (the “how”) should be described in
section 4.3. In this section, describe how that methodology fits within the
proposed schedule of the overall project and project phases (the “when”).
Highlight significant predecessor activities, successor activities, and stage
gates.
The methodology for system configuration (the “how”) should be described
in section 4.3. In this section, describe how that configuration
methodology fits within the proposed schedule of the overall project and
project phases (the “when”). Highlight significant predecessor activities,
successor activities, and stage gates.
The methodology for development (the “how”) should be described in
section 4.3. In this section, describe how that development methodology
fits within the proposed schedule of the overall project and project phases
(the “when”). Highlight significant predecessor activities, successor
activities, and stage gates.
Confidential Page 44 2/27/2014
The methodology for testing (the “how”) should be described in section
4.3. In this section, describe how that testing methodology fits within the
proposed schedule of the overall project and project phases (the “when”).
Highlight significant predecessor activities, successor activities, and stage
gates.
The methodology for user training (the “how”) should be described in
section 4.3. In this section, describe how that user training methodology
fits within the proposed schedule of the overall project and project phases
(the “when”). Highlight significant predecessor activities, successor
activities, and stage gates.
If not covered in above, describe how legacy system integration fits within
the overall project plan.
4.5 Proposed Staffing
Offeror should enclose a resume of each known person projected to be assigned to the
project. Offeror should denote or emphasize staff experience and roles in any utility
projects similar to what GUC is asking for. Offeror should stipulate the proposed “key
resources” that will not be removed from the project nor will their level of participation be
lessened without prior written approval from GUC. Offeror should provide mitigation
plans for loss of key project members. Offeror should describe existing or potential
contractual obligations for each proposed staff member and the Offeror’s strategy for
dealing with such situations. Should Offeror not currently have available all personnel or
resources required for completing the project, a statement should be included which
specifies the Offeror’s plan to acquire necessary staff and resources.
Additionally, the following should be covered:
Provide a proposed staffing plan indicating the number, characteristics,
and schedule for the consultants proposed to support the project.
Provide a proposed GUC staffing plan indicating the number,
characteristics, and schedule for the GUC employees expected to support
the project.
GUC is open to having offshore/nearshore resources perform portions of
the implementation. The following criteria and information must be
provided if offshore/nearshore resources are being proposed:
Confidential Page 45 2/27/2014
o The Prime Contractor will be responsible for the timeliness and quality of
the work done by the offshore/nearshore organization.
o The Prime Contractor must disclose the nature of the relationship between
the Prime Contractor and the offshore/nearshore provider (i.e. wholly
owned subsidiary, third party contractor, partial owner etc.)
o The Prime Contractor should discuss how the work will be managed by
the Prime Contractor and the offshore/nearshore provider.
o The Prime Contractor must disclose what country or countries the work
will be done in by the offshore/nearshore provider.
o The Prime Contractor must disclose how knowledge transfer will be
provided to GUC.
Provide certifications, education and experience in the Solution Set
products.
Provide the number of certified Solution Set consultants in the SI’s pool,
by functional area and skill level. Note how many of these consultants
have utilities experience, and how many have electric, water, wastewater
and natural gas experience.
Provide anticipated and historical consultant turnover rates.
Discuss the offeror’s intent to subcontract for implementation personnel.
Specifically, describe the functions to be subcontracted and the expertise
and credentials required from the subcontractor. Identify each
subcontractor company by name and location.
Provide the number of certified Solution Set consultants available to the SI
from subcontractors, by functional area and skill level. Note how many of
these consultants have utility experience, electric, water, wastewater and
natural gas experience.
Identify the specific individual that will be proposed as project manager,
and provide his or her resume, qualifications, background, and references
(more than one candidate may be proposed.)
For key personnel assigned to the project, identify their role/position and
anticipated duration of participation on the project.
Confidential Page 46 2/27/2014
Describe the process by which the Offeror requests the removal or a
change of a GUC resource on the project.
Describe the process by which GUC requests the removal of a consultant
(prime or subcontractor) from the GUC project.
4.6 Price Proposal
GUC expects each Offeror to present its best price and documented
pricing methodology based on the requirements documented within this
RFP. GUC further expects each Offeror to complete the pricing workbook
(SI Pricing.xls) attached to this RFP.
GUC expects the project to have multiple phases, which are being
generically referred to as Planning, Analysis & Functional Design,
Configuration & Development, Testing, Transition, and Production
Support. GUC desires Time and Material pricing for the Planning and
Analysis & Functional Design phases, and Fixed Price pricing that will be
set at the end of functional design for the remainder of the project. Offeror
should incorporate this pricing method into their overall pricing estimate.
Provide a separate pricing proposal for travel-related expenses and the
rates and assumptions included in developing this proposal. Travel
expenses should not be included in the section above. An optional
template for Travel Assumptions is provided in the document SI
Pricing.xls. Offerors may use this template or their own format for Travel
Assumptions; all assumptions must be clearly documented.
Itemize any cost items that are not included in the price proposal.
Define all project roles, estimated hours by project role and provide a
matrix of hourly rates for each role – at various skill levels and for both
functional and technical consultants. This matrix will serve as the
maximum rates for negotiated work and services beyond the scope of the
Offeror’s proposal, and for additional contracted programming services if
necessary. The Offeror is allowed to use its own format or template for
responding to this data request.
Describe the Offeror’s procedure for pricing change orders.
Confidential Page 47 2/27/2014
Provide fiscal year annual cost estimates based on a project initiation date
of July 14, 2014, and lasting over a 3-year effort projection. GUC’s fiscal
year starts July 1. In addition to the above, respondents are encouraged
to present contract pricing strategies that would best fit their ability to
maintain schedule and reduce costs through an incentive based contract.
In all cases of pricing, it is incumbent on the Offeror to adequately explain
how the pricing will work. GUC must have a clear understanding of the
proposed software’s solution’s Total Cost of Ownership.
4.7 Specified Agreement Concepts
Offerors are expected to returned completed and signed copies of the following
attachments:
APP-G North Carolina E-Verify Statement
APP-H Certified Good Faith Statement
Include proposed replacement language in all cases where an exception is being taken.
The inclusion of contract-related forms shall in no way be construed as an award of a
contract for the services described in this RFP, or any portion thereof, or as an intention
to award a contract. GUC reserves the right to alter, amend or delete any portion of
these forms, to exclude any form, or to require additional forms not listed herein prior to
execution of a contract.