Page 1 of 56 The Municipality of North Middlesex 229 Parkhill Main Street Parkhill, ON N0M 2K0 Ph. No. 519-294-6244 ext. 235 www.northmiddlesex.on.ca REQUEST FOR PROPOSAL for ONE (1) RESCUE FIRE APPARATUS Sealed proposals to be addressed to William Davidson, Director, Emergency and Safety Services/Fire Chief, Municipality of North Middlesex, 229 Parkhill Main Street, Parkhill, ON N0M 2K0, marked “PROPOSAL - RESCUE FIRE APPARATUS” and to be received by 10:00 a.m. Local Time, Tuesday, May 07, 2019. Public Opening 10:10 a.m. Local Time, Tuesday, May 07, 2019. All proposals received will be date and time stamped according to the Municipal Office computer system. Proposals received after the date and time above will not be considered. It is the responsibility of the submitter to ensure their package is received prior to the closing whether sent by mail, courier or delivered in person.

Transcript of REQUEST FOR PROPOSAL for ONE (1) RESCUE FIRE APPARATUS · SERVICE MANUAL SUPPORT As part of the...

Page 1: REQUEST FOR PROPOSAL for ONE (1) RESCUE FIRE APPARATUS · SERVICE MANUAL SUPPORT As part of the standard delivery manual, the proponent shall give a password-protected link to the

Page 1 of 56

The Municipality of North Middlesex 229 Parkhill Main Street Parkhill, ON N0M 2K0

Ph. No. 519-294-6244 ext. 235 www.northmiddlesex.on.ca

REQUEST FOR PROPOSAL

for

ONE (1) RESCUE FIRE APPARATUS

Sealed proposals to be addressed to William Davidson, Director, Emergency and Safety Services/Fire Chief, Municipality of North Middlesex, 229 Parkhill Main Street, Parkhill, ON N0M 2K0, marked “PROPOSAL - RESCUE FIRE APPARATUS” and to be received by 10:00 a.m. Local Time, Tuesday, May 07, 2019. Public Opening 10:10 a.m. Local Time, Tuesday, May 07, 2019. All proposals received will be date and time stamped according to the Municipal Office computer system. Proposals received after the date and time above will not be considered. It is the responsibility of the submitter to ensure their package is received prior to the closing whether sent by mail, courier or delivered in person.

Page 2: REQUEST FOR PROPOSAL for ONE (1) RESCUE FIRE APPARATUS · SERVICE MANUAL SUPPORT As part of the standard delivery manual, the proponent shall give a password-protected link to the

Page 2 of 56

INFORMATION FOR PROPONENTS

1. As per the specifications provided, each manufacturer is invited to submit pricing and delivery for one (1) Rescue Fire Apparatus.

2. The specifications shall be answered on the forms provided or the bid will be disqualified. Each bidder shall submit a set of specifications outlining the exact vehicle proposed.

3. Other bid forms or the submission of alternates, not detailed in the specifications, shall be cause for disqualification.

4. It is the intent that the specifications clearly identify the furnishing and delivery of a complete Rescue Fire Apparatus as specified.

5. Bids submitted will be reviewed and evaluated based on qualifications, bonding, quality programs, irregularities, delivery and price.

6. The purchaser shall be the sole determining organization as to the award of the bid, and the lowest price may not necessarily be accepted.

7. A proponent may submit separate proposals for more than one vehicle.

8. The proponent may withdraw a submitted proposal at any time up to the official closing time by letter bearing a signature and/or seal. Withdrawal requests received after the proposal closing time will not be permitted.

9. In the event that only one proposal is received at time of closing, the Municipality will either open the proposal or delay opening of the proposal until a decision is made as to whether to open or reject the proposal.

10. Any and all changes to the terms, conditions or specifications required before proposal closing will be issued by the Municipality in the form of a written Addendum. If addenda are issued, their receipt must be acknowledged by the proponents.

11. The Municipality reserves the right to accept or reject any and all proposals.

12. The Proposal Form must be completed in ink, in full, signed and returned in a sealed envelope clearly marked with the name and address of the proponent, and labeled “Proposal – Rescue Fire Apparatus”

13. Facsimiles are not acceptable.

14. All prices must be in Canadian funds.

15. Pricing provided shall be held firm for a maximum of thirty (30) calendar days from the RFP closing date.

16. The vehicle shall be delivered in no more than 400 calendar days from the award of the contract to (preference may be given to shorter delivery dates):

Parkhill Fire Station 194 Parkhill Main St.

Parkhill, Ontario

17. Detail the cost of delivery separately as the Municipality may pick up the vehicle from the successful proponent. If applicable.

18. If any payment is required prior to delivery, the proponent shall complete a payment schedule with their submission.

Page 3: REQUEST FOR PROPOSAL for ONE (1) RESCUE FIRE APPARATUS · SERVICE MANUAL SUPPORT As part of the standard delivery manual, the proponent shall give a password-protected link to the

Page 3 of 56

19. The Municipality reserves the right to hold back 10% of payment until such time as the vehicle is proven to perform at expected levels.

BID BOND

A 10% bid bond shall be provided from the apparatus manufacturer. Bonds from sales

representatives, agents, or other parties shall not be recognized or accepted. This bond shall

remain in effect until the time of contract award. (Mandatory Requirement)

WARRANTY

1. The warranties required by the Municipality are noted in Section 35 of the proposal specification. Copies of all warranties shall be included with the bid submission.

2. All warranties shall be binding on the successful proponent over the service life of the apparatus.

3. All warranties from the proponent or any subcontractor, whether or not herein requested for any portion of the unit proposed shall be included in the bid submission.

4. Warranties shall begin on the dates noted in Section 35 of the proposal specification.

TERMS & CONDITIONS

1. The successful proponent shall provide a written contract outlining the scope of the product to be supplied as per the specification document. The contract shall be acceptable to the North Middlesex Fire Department and endorsed by both parties.

2. Vehicle must be supplied with suitable components necessary to ensure safe and satisfactory operation whether or not specified herein.

3. Where minimums are called for, the unit must meet or exceed the minimum stated.

4. The successful proponent shall provide instruction by a qualified and responsible representative of the supplier to a representative of the North Middlesex Fire Department. Topics of instruction shall include but not be limited to operation, care and maintenance of the apparatus and equipment. The training plan is to be included with your proposal submission.

5. Should the vehicle require special tools to perform maintenance, repairs, etc., such tools shall be provided to the North Middlesex Fire Department at the time of delivery and shall be included in the bid price.

6. The proponent will not, without written consent of the Municipality, make any assignment or any subcontract for the execution of any service or product hereby proposed on.

7. In cases of dispute whether a product or service proposed or delivered meets the condition in the accepted proposal, the decision of the Municipality shall be final and binding on all parties.

Page 4: REQUEST FOR PROPOSAL for ONE (1) RESCUE FIRE APPARATUS · SERVICE MANUAL SUPPORT As part of the standard delivery manual, the proponent shall give a password-protected link to the

Page 4 of 56

8. Defective components will not be accepted. Parts, equipment and assemblies that have been repaired or modified to overcome deficiencies shall not be furnished without the written approval of the Municipality.

9. Any welded, bolted or riveted construction utilized shall be in accordance with the accepted standards of the industry. Component parts and units shall be manufactured to definite standard dimensions with proper fits, clearances, and uniformity. The general appearance of the vehicle shall not show any evidence of poor workmanship.

TENDER EVALUATION

This tender will be evaluated on a points system based on the documents submitted with this tender. Failure to submit requested documents may result in your tender being rejected or 0 points being assigned. Evaluation of points being received in each section is at the discretion of the purchaser / fire department. 1) Compliance to Specifications 28 points 2) Design 27 points 3) Price 15 points 4) Warranty 10 points 5) 24 Hour Warranty Policy/ Service within 160 Km 5 points 6) ISO Certificate 3 points 7) Professional Engineering Certificate of Staff Member 3 points 8) C.W.B. Welding Certificates 3 points 9) Insurance Certificate for $25,000,000.00 2 points 10) Fire Apparatus Manufacture Association Certificate 2 points 11) Length of Time in Business / No prototypes 2 points Total 100 points

QUALIFICATION DOCUMENT

All bidders must fill this form out completely. Bids not returned with this form completely filled out will be disqualified. Any blank spaces or noncompliance to Mandatory Requirements could result in the manufacturers bid submittal being disqualified. REQUIREMENTS 1) The manufacturer or designated servicing dealer of the apparatus must be certified and in good standing with the Workers Compensation Board. Proof of certification must be supplied with the bid. A manufacturer or designated servicing dealer that is not in good standing with their local Workers Compensation Board shall be disqualified. (Mandatory Requirement) Comply (Yes/No) _____________ Certificates Attached (Yes/No) ________________ 2) The bidder shall provide a "24 Hour", "7-Day Per Week" emergency parts and service toll free telephone number. This phone number must be listed on a separate statement included in the bid package, along with the contact name, business name, address, and phone number of the local service agency, which will service the vehicle after being placed into service. The service

Page 5: REQUEST FOR PROPOSAL for ONE (1) RESCUE FIRE APPARATUS · SERVICE MANUAL SUPPORT As part of the standard delivery manual, the proponent shall give a password-protected link to the

Page 5 of 56

agency shall be capable to perform all required service work, and shall also have at their disposal the ability to have any required subcontracting work, such as engine, transmission, etc. work performed on behalf of the apparatus manufacturer. (Mandatory Requirement) Comply (Yes/No) __________ 3) The bidder shall have a documented and certified ISO 9001 quality program in place. A copy of the certifications must be included with the bid submittal. The apparatus manufacturer shall provide the name of the ISO provider, as well as the ISO providers contact information including phone number. In the event the bidder uses an alternative documented quality check process, documentation outlining the process and certification, if applicable, shall be included with the bid submission similar to that as described above. Comply (Yes/No) __________ Certificates Attached (Yes/No) ________________ Contact Information Attached (Yes/No) __________ 4) The apparatus manufacturer must provide documentation of having a certified engineer on staff with the bid submittal. Sub Contracted Engineers Shall Not Be Acceptable and Shall Disqualify The Bid. (Mandatory Requirement) Comply (Yes/No) __________ Certificates Attached (Yes/No) _____________ 5) All welding on the apparatus body and plumbing systems must be performed by certified welders. Copies of the certification must be attached with the bid submittal. (Mandatory Requirement) (Yes/No)_______________ Certificates Attached (Yes/No) _____________ 6) The manufacturer of the apparatus must supply a Certificate of Insurance detailing liability insurance coverage. Product liability insurance coverage of a minimum of $25,000,000.00 is preferred. (Yes/No) ____________ Certificate Attached (Yes/No) _____________ 7) The apparatus manufacturer must be a current member of the Fire Apparatus Manufacturers Association (FAMA). A copy of the certificate must be attached with the bid submittal. (Yes/No) _____________ Certificates Attached (Yes/No) ____________ 8) The bidder must have been manufacturing fire apparatus continuously, under the same ownership without interruption for a minimum of twenty (20) years. (Mandatory Requirement) (Yes/No)________________ Certificates Attached (Yes/No) _____________

Page 6: REQUEST FOR PROPOSAL for ONE (1) RESCUE FIRE APPARATUS · SERVICE MANUAL SUPPORT As part of the standard delivery manual, the proponent shall give a password-protected link to the

Page 6 of 56

ENGINEERING DRAWINGS The proponent shall submit with the "proposal" blueprints which are “representative” of the vehicle being proposed and these have been generated on computer-aided-design (CAD) equipment. The blueprints submitted shall be on "B" size paper, 11" x 17" in size and views are on 1/16" to 1" scale. The blueprints are provided as follows: Left side exterior view Right side exterior view Rear exterior view Front view Top View The proponent shall provide construction drawings for approval prior to actual construction of the vehicle. The design of the equipment is in accordance with the best engineering practices. The equipment design and accessory installation shall permit accessibility for use, maintenance and service. All components and assemblies shall be free of hazardous protrusions, sharp edges, cracks or other elements, which might cause injury to personnel or equipment. All oil, hydraulic, and air tubing lines and electrical wiring shall be located in protective positions properly attached to the frame or body structure and shall have protective loom or grommets at each point where they pass through structural members, except where a through-frame connector is necessary. Parts and components will be located or positioned for rapid and simple inspection and recognition of excessive wear or potential failure. Whenever functional layout of operating components determines that physical or visual interference between items cannot be avoided, the item predicted to require the most maintenance shall be located for best accessibility.

SERVICE MANUAL SUPPORT As part of the standard delivery manual, the proponent shall give a password-protected link to the end user, allowing access to the manufacturers' database on service parts. The internet-based system shall allow the end user to access the major component supplier's service parts listing such as Hale, Waterous, Akron, etc. This shall be accomplished with simplistic point and click features on the manufacturer line item within the "stripper" or "line item sheet". This will include automatic updates, printable schematics and manufacturer's web links and be available in the commercially available format of Adobe Acrobat Reader to access these documents. As

Page 7: REQUEST FOR PROPOSAL for ONE (1) RESCUE FIRE APPARATUS · SERVICE MANUAL SUPPORT As part of the standard delivery manual, the proponent shall give a password-protected link to the

Page 7 of 56

an alternative One (1) compact disc manual(s) may be provided on the operation of the complete apparatus. The CD manual(s) shall include a troubleshooting guide complete with recommended daily, weekly and annual maintenance procedures as well as a complete colour coded wiring diagram.

Page 8: REQUEST FOR PROPOSAL for ONE (1) RESCUE FIRE APPARATUS · SERVICE MANUAL SUPPORT As part of the standard delivery manual, the proponent shall give a password-protected link to the

Page 8 of 56

PROPOSAL FORM

MUNICIPALITY OF NORTH MIDDLESEX

PROPOSAL FOR ONE (1) RESCUE FIRE APPARATUS This quote for the supply of one (1) new Rescue Fire Apparatus

is submitted by:

In accordance with the accompanying specifications, I/We declare the goods submitted herein completely comply or have provided documented exceptions for the fore mentioned specification.

I/We propose and agree to supply this unit for the following quotation price:

PROPOSAL FORM – RESCUE FIRE APPARATUS

VEHICLE MAKE

VEHICLE MODEL

PRODUCTION YEAR

MANUFACTURED AT

PRICE (words)

Harmonized Sales Tax $

Other Applicable Charges $

TOTAL PROPOSAL PRICE (Canadian Funds) $

PLEASE INCLUDE PAYMENT SCHEDULE IF APPLICABLE.

NOTE: Lowest, or any proposal not necessarily accepted. Dated this day of , 2019. Witness Signature of Signing Officer or Owner

Position in Firm

Name of Firm

Page 9: REQUEST FOR PROPOSAL for ONE (1) RESCUE FIRE APPARATUS · SERVICE MANUAL SUPPORT As part of the standard delivery manual, the proponent shall give a password-protected link to the

NORTH MIDDLESEX FIRE DEPARTMENT SPECIFICATIONS RESCUE FIRE APPARATUS

SPECIFICATION DOCUMENT

Page 9 of 56

1. GENERAL INSTRUCTIONS ................................................................................................................ 11

2. TRAINING ........................................................................................................................................ 13

3. COMMERCIAL CHASSIS ................................................................................................................... 14

4. ENGINE ............................................................................................................................................ 15

5. ENGINE AIR INTAKE ......................................................................................................................... 15

6. EXHAUST SYSTEM............................................................................................................................ 16

7. TRANSMISSION ............................................................................................................................... 16

8. CAB INTERIOR.................................................................................................................................. 16

9. CAB EXTERIOR ................................................................................................................................. 19

10. DIMENSIONS ............................................................................................................................... 19

11. STEERING AXLE ............................................................................................................................ 20

12. REAR AXLE ................................................................................................................................... 20

13. TIRES & WHEELS .......................................................................................................................... 21

14. FUEL SYSTEM ............................................................................................................................... 21

15. BRAKE SYSTEM ............................................................................................................................ 21

16. CHASSIS WIRING ......................................................................................................................... 22

17. BODY WIRING .............................................................................................................................. 24

18. INTERIOR LIGHT & ACCESSORIES ................................................................................................ 27

19. EXTERIOR LIGHTS ........................................................................................................................ 28

20. WARNING DEVICES ..................................................................................................................... 33

21. RADIO SYSTEM ............................................................................................................................ 36

22. RESERVED .................................................................................................................................... 36

23. GENERATOR ................................................................................................................................ 37

24. RESERVED .................................................................................................................................... 38

25. RESERVED .................................................................................................................................... 38

26. RESERVED .................................................................................................................................... 38

27. BODY ........................................................................................................................................... 38

28. COMPARTMENT CONSTRUCTION ............................................................................................... 39

29. COMPARTMENT LAYOUT ............................................................................................................ 40

30. HYDRAULICS ................................................................................................................................ 45

Page 10: REQUEST FOR PROPOSAL for ONE (1) RESCUE FIRE APPARATUS · SERVICE MANUAL SUPPORT As part of the standard delivery manual, the proponent shall give a password-protected link to the

NORTH MIDDLESEX FIRE DEPARTMENT SPECIFICATIONS RESCUE FIRE APPARATUS

SPECIFICATION DOCUMENT

Page 10 of 56

31. RESERVED .................................................................................................................................... 45

32. STEPS & HANDRAILS .................................................................................................................... 46

33. PAINT, FINISH & LETTERING ........................................................................................................ 49

34. APPARATUS TESTING .................................................................................................................. 51

35. WARRANTY & SERVICE ................................................................................................................ 52

36. DELIVERY ..................................................................................................................................... 53

37. LOOSE EQUIPMENT ..................................................................................................................... 53

38. OPTIONS ...................................................................................................................................... 54

Page 11: REQUEST FOR PROPOSAL for ONE (1) RESCUE FIRE APPARATUS · SERVICE MANUAL SUPPORT As part of the standard delivery manual, the proponent shall give a password-protected link to the

NORTH MIDDLESEX FIRE DEPARTMENT SPECIFICATIONS RESCUE FIRE APPARATUS

SPECIFICATION DOCUMENT

Page 11 of 56

1. GENERAL INSTRUCTIONS

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

a. The bidder shall submit four (4) sets of completed Qualification Documents, Proposal Forms, Specification Documents and Attachments.

b. For each item in this RFP, the “Yes/No” column of the form must be completed. Bidder shall indicate “Yes” only where the equipment or service provided will fully comply with that item. If the mandatory criteria cannot be supplied, “No” shall be indicated and the “Specification/Variations” column must be completed with the specifics of the proposed alternatives. If necessary, the Bidder may also supply a separate document fully detailing the variation on a separate page, referring to the section and the item number.

c. Where the RFP asks for information the answer must appear in the “Specification/Variations” column. If more space is required the information may be provided on a separate page, referring to the section and the item number.

d. The bidder shall specifically point out in their written RFP any circumstances where the minimum specification requirements may not be met.

e. Proposals which do not meet specification, and for which retrofitting is impractical, will be disqualified.

f. The warranty coverage applicable to various components or assemblies shall be specified. Such warranty coverage to become effective from the date the apparatus is placed in service.

g. Proposals must be based on a new apparatus. The apparatus and all accessory items shall be in current use in the fire service and have parts availability within a reasonable time/distance.

State parts/warranty dealer and location:

h. All bidders must supply a five (5) view drawing of the truck proposed. Drawings which are “For reference only” shall not be acceptable.

i. Unless otherwise specified, construction shall meet or exceed CAN/ULC S515-13 standards and NFPA 1901 latest edition.

j. All items offered must comply with the requirements of all applicable Canadian Federal and Provincial (ON) regulations.

k. The specifications are to be considered as a minimum requirement and do not relieve the vendor of the responsibility of supplying a complete fully functional unit, suitable for the service intended.

l. Bidder shall state the after sales service and parts support provided.

m. The apparatus and equipment shall comply with the Canadian Motor Vehicle Safety Standards and all Federal and Provincial Motor Apparatus laws that are applicable to the apparatus being used in Ontario.

Page 12: REQUEST FOR PROPOSAL for ONE (1) RESCUE FIRE APPARATUS · SERVICE MANUAL SUPPORT As part of the standard delivery manual, the proponent shall give a password-protected link to the

NORTH MIDDLESEX FIRE DEPARTMENT SPECIFICATIONS RESCUE FIRE APPARATUS

SPECIFICATION DOCUMENT

Page 12 of 56

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

n. Documentation supporting the vehicle is to be delivered with the vehicle, such documentation will include: One maintenance manual and one parts list (in hard

copy) and one additional copy on CD­ROM. Two operator manuals. One set of repair manuals (hard copy and on

CD­ROM) Instructions shall include service, maintenance, repair and troubleshooting procedures for major and minor components of the chassis. A table of contents, wiring and air schematics shall be included. Parts lists shall include description, part numbers and quantities of all major and minor components.

One “as built” body wiring diagrams.

o. A minimum of one (1) pre-construction meeting shall take place at a place and time suitable to the North Middlesex Fire Department.

p. One (1) Mid-Point inspection trip for two (2) Fire Department personnel shall be made to the facility at the completion of body construction and prior to paint application. Air travel (for distances over 400 km), meals and lodging expenses shall be included. This Mid-Point inspection may also be achieved through live video conferencing at a time acceptable to the North Middlesex Fire Department.

State actual:

q. One (1) Final inspection trip for two (2) Fire Department personnel shall be made to the facility at the completion of construction of the apparatus including all bracketry and mounting hardware. Air travel (for distances over 400 km), meals, and lodging expenses shall be included.

r. The GAWR, and GCWR or GVWR of the chassis shall be adequate to carry the fully equipped apparatus including: all tanks; reservoirs; personnel weight; and any miscellaneous equipment allowance of 5000 lb. (2268 kg). The successful proponent shall calculate the unequipped personnel weight at 250 lb. (91 kg) per person, times five (5) persons to ride the apparatus. The successful proponent shall supply the final manufacturer’s certification of GVWR or GCWR, and GAWR on a nameplate affixed to the vehicle.

State GVW:

s. Every aspect of the apparatus design shall be compliant with the standards set out by the current

Page 13: REQUEST FOR PROPOSAL for ONE (1) RESCUE FIRE APPARATUS · SERVICE MANUAL SUPPORT As part of the standard delivery manual, the proponent shall give a password-protected link to the

NORTH MIDDLESEX FIRE DEPARTMENT SPECIFICATIONS RESCUE FIRE APPARATUS

SPECIFICATION DOCUMENT

Page 13 of 56

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

version of “NFPA 1901- Standard for Automotive Fire Apparatus” at the time of manufacture. The height of the vehicle's center of gravity shall not exceed the chassis manufacturer's maximum limit. State the actual number of inches from the ground for the center of gravity The front to rear weight distribution of the fully loaded vehicle as defined in NFPA 1901, Section 8-1 shall be within the limits set by the chassis manufacturer. Front axle loads, when fully loaded, shall not be less than the minimum axle loads specified by the chassis manufacturer. The difference in weight from side to side on each axle, when the vehicle is fully loaded and equipped as defined in NFPA 1901, Section 8-1, shall not exceed 7 percent.

State centre of gravity: State the actual weight distribution: State the actual weight distribution:

t. The completed apparatus shall be treated prior to delivery with a rust proofing application that creates a barrier of protection for metals and neutralizes the harmful effects of salt and moisture. Rust proofing products/applications utilizing tars, waxes and tackified oils are not acceptable.

State rust proofing product and application:

u. Hydraulic lines, air system tubing, control cables and electrical lines shall be clipped to the frame or body structure of the apparatus and shall be furnished with metal protective looms or grommets at each point where they pass through body panels or structural members.

Exception: Where the design provides a through-the-frame connector, metal protective looms or grommets shall not be required.

State Actual Component Protection Method:

2. TRAINING

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

a. Training sessions shall be provided by a qualified factory technician upon delivery. The intention is to have sufficient training sessions for each operator to become comfortable with key features relevant to the operator. These sessions will not be consecutive, and must be coordinated with the North Middlesex Fire Department.

Outline Training Plan:

Page 14: REQUEST FOR PROPOSAL for ONE (1) RESCUE FIRE APPARATUS · SERVICE MANUAL SUPPORT As part of the standard delivery manual, the proponent shall give a password-protected link to the

NORTH MIDDLESEX FIRE DEPARTMENT SPECIFICATIONS RESCUE FIRE APPARATUS

SPECIFICATION DOCUMENT

Page 14 of 56

3. COMMERCIAL CHASSIS

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

a. A three-piece 14 inch chromed steel bumper with collapsible ends shall be provided. No extension required.

b. A rearview camera system shall be provided. The camera shall activate when the transmission is placed in reverse.

State detail:

c. Two (2) corrosion proof chrome tow eyes shall be mounted directly to the chassis frame rails, on each side of the front bumper. The eyes are to be close ended to allow for the towing of the apparatus as well as anchor points for technical rescue operations.

d. Two (2) corrosion proof chrome tow eyes shall be mounted directly to the chassis frame rails, on each side, at the rear of the apparatus. They shall be mounted in an easily accessible location but not in a position to become a trip/safety hazard when working around the apparatus. The eyes are to be close ended to allow for the towing of the apparatus as well as anchor points for technical rescue operations.

e. The angle of approach and angle of departure shall be within the specifications outlined by the most current NFPA 1901 standards.

State angle of approach: State angle of departure:

f. The vehicle shall be equipped with an electronic stability control system which utilizes the chassis manufacture’s anti-lock braking and throttle control systems to aid in the prevention of vehicle rollover.

g. The apparatus shall be mounted on a new domestic commercially produced, four (4) door chassis with seating capacity for five (5). The preferred chassis is a Freightliner M2106 or International MV.

State Actual

h. In addition to the standard features, the cab shall include: One (1) Exterior Sunvisor Tinted door glass windows Power door windows No rear cab window Electric windshield wipers with an intermittent function Hood mounted plastic chrome grille Hood mounted chrome air intake High output fresh air heater/defroster with fresh air re-

Page 15: REQUEST FOR PROPOSAL for ONE (1) RESCUE FIRE APPARATUS · SERVICE MANUAL SUPPORT As part of the standard delivery manual, the proponent shall give a password-protected link to the

NORTH MIDDLESEX FIRE DEPARTMENT SPECIFICATIONS RESCUE FIRE APPARATUS

SPECIFICATION DOCUMENT

Page 15 of 56

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

circulation and air conditioning

i. The commercial chassis is to include an air ride cab.

j. The chassis cab shall be equipped with stainless steel mirrors. Mirrors shall include the following:

Power control, drivers side and passenger side

Mirrors shall be heated, drivers side and

passenger side

LED clearance lights mounted on each mirror

Mirrors shall be flat “West Coast” type with 8”

convex lower mirror

k. The manufacturer shall calculate the alternator size required. A minimum of 275 amp alternator shall be supplied.

State actual amperage rating:

4. ENGINE

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

a. The engine shall be an electronically governed, turbocharged diesel engine with a minimum 350 hp. The preferred engine is a Cummins diesel.

State make, model and hp:

b. The engine shall carry the manufacturer’s standard warranty. State warranty:

c. The engine shall have an air compressor sufficient for fire service application.

State make, model and CFM:

d. An engine hour meter shall be mounted in the cab and incorporated into the gauge package.

e. The apparatus shall be equipped with an auxiliary braking system with controls mounted on the dash. The preferred method is a Turbo Brake or equivalent.

State actual:

f. A programmable high idle switch shall be provided and mounted in the cab. It shall be pre-set so when activated, it will operate the engine at the appropriate RPM to increase alternator output and optimize output of the HVAC system.

g. The engine cooling system fan shall incorporate a thermostatically controlled, clutched type fan drive. When the clutched fan is disengaged it shall facilitate improved vehicle performance, cab heating in cold climates, and fuel economy. The fan clutch design shall be fail safe so that if the clutch drive fails, the fan shall engage to prevent engine overheating due to the fan clutch failure. Auto Fan Control system shall also include a dash switch and indicator light, not engine mounted.

State make:

5. ENGINE AIR INTAKE

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

a. A dry type two stage cleaner shall be provided that is properly sized for use with the specified engine. The air

Page 16: REQUEST FOR PROPOSAL for ONE (1) RESCUE FIRE APPARATUS · SERVICE MANUAL SUPPORT As part of the standard delivery manual, the proponent shall give a password-protected link to the

NORTH MIDDLESEX FIRE DEPARTMENT SPECIFICATIONS RESCUE FIRE APPARATUS

SPECIFICATION DOCUMENT

Page 16 of 56

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION cleaner shall have an ember separator, a readily accessible replaceable element and shall meet the engine manufacturer’s guidelines for intake restriction. An intake restriction indicator shall be provided.

6. EXHAUST SYSTEM

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

a. The exhaust system shall be shielded to prevent any heat damage to compartments, wiring, plumbing or any other surrounding component of the truck.

b. The Diesel Exhaust Fluid (DEF) tank shall have a minimum capacity of not less than five (5) usable gallons. The DEF tank shall be designed with capacity for expansion in case of fluid freezing. Engine coolant, which shall be thermostatically controlled, shall be run through lines in the tank to help prevent the DEF from freezing and to provide a means of thawing the fluid if it should become frozen.

c. The DEF system shall have indicators and controls on the driver’s dash. The indicators shall indicate;

DEF fluid level

Regen required

Regen Active

Regen fault The controls shall provide a means to control;

Regen inhibit

Forced regen

d. The chassis exhaust system shall exit horizontally on the passenger side of the vehicle.

7. TRANSMISSION

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

a. An Allison EVS 3000 automatic transmission with electronic controls shall be provided. The automatic transmission range selector shall be a key pad type shifter, illuminated for night operation and shall be located to the right of the driver. A transmission temperature gauge with warning light and buzzer shall be mounted in the cab.

b. The transmission shall be programmed to automatically shift into neutral upon application of the park brake.

c. Transmission shall be supplied with synthetic lubricant. An electronic oil level sensor shall be included with the readout located in the shift selector.

8. CAB INTERIOR

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

Page 17: REQUEST FOR PROPOSAL for ONE (1) RESCUE FIRE APPARATUS · SERVICE MANUAL SUPPORT As part of the standard delivery manual, the proponent shall give a password-protected link to the

NORTH MIDDLESEX FIRE DEPARTMENT SPECIFICATIONS RESCUE FIRE APPARATUS

SPECIFICATION DOCUMENT

Page 17 of 56

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

a. The ceiling of the cab shall be covered with headliner material.

State material/finish:

b. The driver’s seat shall be H.O. Bostrom Sierra Air-50 high back air suspension driver’s seat with adjustable recline, fixed lumbar and NFPA 1901-2009 compliant seat sensor.

c. The passenger seat shall be H.O. Bostrom Tanker 450 SCBA Non Suspension seat with under seat storage, Secureall ready cushion and NFPA 1901-2009 compliant seat sensor. The seats shall be equipped with one (1) Bostrom Secureall SCBA bracket capable of being adjusted to fit any size bottle or brand of SCBA currently on the market. An NFPA approved and patented auto-lock mechanism shall hold the SCBA in place for a secure fit in all directions. The integrated one-touch release handle shall be located in the seat cushion for a quick and easy exit.

d. The rear passenger seats shall be H.O. Bostrom Tanker 450 SCBA Non Suspension LH, RH and Center rear passenger seats with under seat storage, Secureall ready cushion and NFPA 1901-2009 compliant seat sensor. The seats shall be equipped with five (5) Bostrom Secureall SCBA brackets capable of being adjusted to fit any size bottle or brand of SCBA currently on the market. An NFPA approved and patented auto-lock mechanism shall hold the SCBA in place for a secure fit in all directions. The integrated one-touch release handle shall be located in the seat cushion for a quick and easy exit.

e. Preferred interior cab upholstery to be dark grey or black in colour.

State colour:

f. An electrical console shall be constructed of .125" black thermoplastic coated smooth aluminum material and mounted in the cab of the truck chassis. The console will have a black bed lined finish on the exterior of the compartment. Console shall be designed and installed between the driver and passenger seats. The top face of the console shall be designed as the switch panel for all emergency light switches. The switch panel shall be bolted in place for easy access to the switch connections. All emergency light switches shall be lighted, rocker style. Switches shall be internally lit when the switch circuit is in the on position. A plug-in identification label is to be provided and installed adjacent to each rocker switch with backlighting provided behind the label. A rocker style internally lighted switch shall be provided and wired through a heavy-duty relay to activate power to the emergency lights. A single “MASTER SWITCH” on the electrical console shall activate the emergency lights. An area of the console is to be designed to store hardcopy reference material. Preferably located at the front or rear of the console, the area is to safely accommodate a standard 2” binder, Transport Canada Emergency Response Guidebook and clipboard at minimum.

State detail:

Page 18: REQUEST FOR PROPOSAL for ONE (1) RESCUE FIRE APPARATUS · SERVICE MANUAL SUPPORT As part of the standard delivery manual, the proponent shall give a password-protected link to the

NORTH MIDDLESEX FIRE DEPARTMENT SPECIFICATIONS RESCUE FIRE APPARATUS

SPECIFICATION DOCUMENT

Page 18 of 56

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION The final console design is to be approved by the North Middlesex Fire Department prior to fabrication.

g. A dark coloured durable vinyl type pebble grain texture floor covering material shall be provided. The floor covering shall have soundproof insulation for outside noise. The cab entrance step well areas shall be covered with aluminum tread plate.

State colour and material:

h. Driver and passenger doors shall have reflective material installed on the doors inner edge to meet NFPA requirements when apparatus passenger compartment doors are in the open position.

i. Sun visors for both front seat positions shall be installed.

j. Speedometer/odometer (speedometer to be in kilometres/hour) Tachometer with hour meter Oil pressure gauge Transmission temperature gauge Dual air pressure gauge Coolant temperature gauge Fuel level gauge Voltmeter Low coolant warning light & buzzer High temperature engine coolant warning light & buzzer Low engine oil pressure warning light & buzzer Air cleaner restriction warning light Parking brake indicator light Automatic reset circuit breakers

k. The following labels shall be in the cab and in full view of the driver and passenger from their normal seated positions:

One (1) seat belt warning label with the

words,” Occupants must be seated and

belted when apparatus is in motion".

One (1) label stating “Do not store helmets

in cab while vehicle is in motion”

One (1) label stating the number of

personnel the vehicle is designed to carry.

One (1) label stating overall height in both

metres and feet.

One (1) label stating the overall loaded

vehicle weight in both pounds and

kilograms.

One fluid capacity data label as per NFPA

specifications

Page 19: REQUEST FOR PROPOSAL for ONE (1) RESCUE FIRE APPARATUS · SERVICE MANUAL SUPPORT As part of the standard delivery manual, the proponent shall give a password-protected link to the

NORTH MIDDLESEX FIRE DEPARTMENT SPECIFICATIONS RESCUE FIRE APPARATUS

SPECIFICATION DOCUMENT

Page 19 of 56

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

l. One (1) proximity door switch shall be installed and wired into each compartment door opening for the purposes of automatically activating a dash mounted flashing indicator when any door is ajar. The light shall be LED, approximately 1" in diameter, red in colour, labelled "Do Not Move Apparatus" and located in full view of the driver.

m. One (1) proximity switch shall be installed and wired to the Light Tower as described in 19 h. or 38 a. for the purpose of automatically activating a dash mounted flashing indicator when the Light Tower is not in its fully stowed position. The warning light shall be the same light as used to indicate when a compartment door is ajar in 8 l.

9. CAB EXTERIOR

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

a. All metal door handles shall have a backing plate to prevent paint scratching and wear.

b. The cab exterior shall be painted utilizing existing North Middlesex Fire Department red colour. Exact colour will be discussed at the pre­construction meeting.

c. A paint spray out, for Fire Department approval, shall be provided prior to the cab being painted.

10. DIMENSIONS

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

a. The apparatus shall have the following exterior dimensions including all mirrors, ladders, lights and any item that is mounted on the apparatus.

b. Wheelbase (as determined by the manufactures calculations)

Cab to Axle (as determined by the manufactures calculations)

G.V.W Rating (as determined by the manufactures calculations) Overall Apparatus Body Width (as determined by the manufactures calculations) – state actual The overall apparatus width is not to exceed 102” Overall Apparatus Length (as determined by the manufactures calculations) The overall apparatus length is not to exceed 34’

State actual Wheelbase: State actual: State actual GVW: State actual O/A width: Sate actual O/A length:

Page 20: REQUEST FOR PROPOSAL for ONE (1) RESCUE FIRE APPARATUS · SERVICE MANUAL SUPPORT As part of the standard delivery manual, the proponent shall give a password-protected link to the

NORTH MIDDLESEX FIRE DEPARTMENT SPECIFICATIONS RESCUE FIRE APPARATUS

SPECIFICATION DOCUMENT

Page 20 of 56

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

Overall Apparatus Height (as determined by the manufactures calculations) The overall apparatus height is not to exceed 123” (as determined prior to the addition of any personnel or equipment).

Sate actual O/A height:

11. STEERING AXLE

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

a. The steering column shall have an integral, self-canceling turn signal and a padded steering wheel.

b. The steering column shall contain a horn button, four way hazard switch and head lamp dimmer switch on turn lever.

c. A multi adjustable tilting and telescoping steering column shall be supplied.

d. FRONT SUSPENSION - DETAILS

Front Axle: (as determined by the manufactures calculations)

Front Suspension: (as determined by the manufactures calculations)

Front Spring Rating: (as determined by the manufactures calculations)

Front Axle Rating: (as determined by the manufactures calculations)

Wheel Fastening: (as determined by the manufactures calculations)

State actual front axle: State actual front suspension: State actual front spring rating: State actual front axle rating: State actual wheel fastening:

12. REAR AXLE

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

a. The rear axle must have sufficient capacity to carry the trucks finished weight.

State capacity:

b. REAR SUSPENSION - DETAILS Rear Axle: (as determined by the manufactures calculations) Rear Suspension: (as determined by the manufactures calculations) Rear Spring Rating: (as determined by the

State actual rear axle: State actual rear suspension: State actual rear spring rating:

Page 21: REQUEST FOR PROPOSAL for ONE (1) RESCUE FIRE APPARATUS · SERVICE MANUAL SUPPORT As part of the standard delivery manual, the proponent shall give a password-protected link to the

NORTH MIDDLESEX FIRE DEPARTMENT SPECIFICATIONS RESCUE FIRE APPARATUS

SPECIFICATION DOCUMENT

Page 21 of 56

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

manufactures calculations) Rear Axle Rating: (as determined by the manufactures calculations) Wheel Fastening: (as determined by the manufactures calculations)

State actual rear axle rating: State actual wheel fasteners:

13. TIRES & WHEELS

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

a. Two (2) front tires shall be supplied that will be sufficient for the G.V.W. of the fully equipped apparatus, matched to the rated axle weight, and turning radius. The tires shall be Goodyear G182 RSD (or equivalent) with a highway tread.

State make and size:

b. Four (4) rear tires shall be supplied that will be sufficient for the G.V.W. of the fully equipped apparatus and matched to the rated axle weight. The tires shall be Goodyear G282 MSD (or equivalent) mud and snow tread.

State make and size:

c. The front wheels and outer rear wheels shall be hub piloted, bright finish aluminium construction. Alcoa Dura-Bright are preferred.

State actual:

d. The front wheels and outer rear wheels shall be equipped with stainless steel lug nut and hub covers.

e. Each wheel/tire assembly shall be equipped with a visual indicator or monitoring system that will indicate tire pressure.

State type and design:

14. FUEL SYSTEM

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

a. The fuel tank shall be 50 US gallons. State capacity:

b. The fuel tank shall be provided with a high capacity filler neck size with no flow restrictions.

c. A fuel filler port shall be provided clearly marked with the words “DIESEL FUEL ONLY”.

d. A fuel/water separator shall be provided and installed within the chassis fuel system. The separator shall be installed to allow replacement without fuel spillage. i.e. with isolation shut off valves if necessary.

State make and model:

e. The fuel tank shall be located on the left side of the apparatus.

State actual:

15. BRAKE SYSTEM

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

a. Braking system must meet Canadian Motor Vehicle standards and current ULC braking specifications.

b. The brake system shall also incorporate an air dryer, complete with heater.

Page 22: REQUEST FOR PROPOSAL for ONE (1) RESCUE FIRE APPARATUS · SERVICE MANUAL SUPPORT As part of the standard delivery manual, the proponent shall give a password-protected link to the

NORTH MIDDLESEX FIRE DEPARTMENT SPECIFICATIONS RESCUE FIRE APPARATUS

SPECIFICATION DOCUMENT

Page 22 of 56

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

c. Brake stroke indicators shall be installed on each brake chamber.

d. All reservoirs shall be equipped with automatic drains as well as a pull cord system for manually draining the reservoirs. The pull cords shall be extended to the side of the truck and labelled.

e. The air brake system shall be equipped with an electric compressor and 110V shoreline to keep the system air pressure charged while parked in the fire station. (see Section 16-e. for details)

f. The vehicle shall be equipped with an Anti­lock Braking System (ABS) to provide controlled stopping under emergency braking conditions.

State type:

g. The ABS shall have the ability to provide Automatic Traction Control (ATC). The ATC shall apply the ABS when drive wheels spin in slippery conditions to aid in better traction for acceleration. There shall be a dash mounted ATC selector switch that allows the ATC to be turned on. The ATC shall default to the off position.

h. The ABS shall have the ability to provide Enhanced Stability Control (ESC). The ESC shall provide automatic ABS and throttle control to aid in maintaining vehicle stability.

16. CHASSIS WIRING

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

a. Sufficient batteries with a minimum of 625 Cold Cranking Amps (CCA) each shall be provided and shall be easily accessible but contained within an enclosure as to reduce road grime.

State CCA and number of batteries:

b. Battery jumper studs shall be provided. The studs shall allow the vehicle to be jump started or charged in the event of battery failure and be easily accessible.

State location:

c. A master battery disconnect switch shall be provided equipped with an indicator light to indicate the “ON” position. The switch shall be located inside at the driver’s door sill area.

State location:

d. Two (2) 12volt power point receptacles shall be installed on the dash to power external electronic equipment. The receptacles shall be powered only when the master battery disconnect switch is in the “ON” position.

e. One (1) Kussmaul Pump Plus 1200 battery charger and air compressor system shall be installed. The pump shall be equipped with an automatic drain routed to the exterior of the vehicle. The unit shall be mounted in a clean dry area and will be accessible for service and/or maintenance.

f. There shall be a Kussmaul 20-amp super auto eject with yellow cover supplied. The shoreline shall be located near the driver’s door. A Battery Charger Indicator shall be located on the interior of the cab and viewable from the exterior while standing at ground level, with the driver’s door open.

Page 23: REQUEST FOR PROPOSAL for ONE (1) RESCUE FIRE APPARATUS · SERVICE MANUAL SUPPORT As part of the standard delivery manual, the proponent shall give a password-protected link to the

NORTH MIDDLESEX FIRE DEPARTMENT SPECIFICATIONS RESCUE FIRE APPARATUS

SPECIFICATION DOCUMENT

Page 23 of 56

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

g. A 110V AC power receptacle shall be provided in the cab. This receptacle shall be connected to the shoreline power system. The exact location of the receptacle will be discussed at the pre­construction meeting.

h. The apparatus "Electrical Distribution System" (EDS) shall be mounted in a sealed weather proof box and located away from water spray conditions. The main body junction panel shall house the automatic reset breakers and relays where required. The main body junction panel shall be located in the pump compartment.

i. One (1) 12 volt dual USB power outlet with 5 volt 2.1 amp output shall be provided in the centre cab console. The outlet will provide for a minimum of two (2) USB devices to be connected at one time. The outlet shall be powered only when the master battery disconnect switch is in the “ON” position.

j. Chassis wiring/cabling may be accomplished through the use of multiplexing or a 12 Volt electrical system.

Cables shall be mounted in the frame and protected from water and heat.

The chassis cab, engine and transmission shall be electrically bonded to the chassis frame rails with braided ground straps. All rocker type dash switches shall be non-load bearing and shall be clearly marked and back lighted. All rocker type switches shall be operated in the same direction (i.e. top is "on" and bottom is "off'). Colour coding shall be determined at pre-construction meeting. The alternator shall be connected to the power and ground distribution system with cables sized to carry the Manufacture’s rated alternator output. The successful proponent shall provide a written statement identifying all amperage required/used by the vehicle, as well as any recommendation for a higher amp alternator based upon need. Two (2) complete, CLEAR LAMINATED circuit diagrams shall be provided with the apparatus. Exposed cabling (regardless of whether or not it is protected inside of a loom) will not be allowed in compartment interiors.

Page 24: REQUEST FOR PROPOSAL for ONE (1) RESCUE FIRE APPARATUS · SERVICE MANUAL SUPPORT As part of the standard delivery manual, the proponent shall give a password-protected link to the

NORTH MIDDLESEX FIRE DEPARTMENT SPECIFICATIONS RESCUE FIRE APPARATUS

SPECIFICATION DOCUMENT

Page 24 of 56

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

k. The apparatus shall be equipped with a Class1 Seat Belt

Warning System” (SBW) that is connected to the power train CAN (Controller Area Network) bus consisting of transmission (TCM), engine control (ECM) and anti-lock

brake (ABS) modules mounted on the apparatus. The SBW will function per NFPA 1901-2009 14.1.3.10 (Seat Belt Warning) using the Class1 “Seat Belt Input Module” for seat occupied and belt status information.

SEAT BELT WARNING DISPLAY

A small rocker style display shall be installed in the chassis cab for the seat belt warning system.

l. The apparatus shall be equipped with a Class1 “Vehicle Data Recorder (VDR) that is connected to the power train CAN (Controller Area Network) bus consisting of transmission (TCM), engine control (ECM) and anti-lock brake (ABS) modules mounted on the apparatus. The VDR will function per NFPA 1901-2009 sections 4.11 (Vehicle Data Recorder) utilizing the power train s J1939 data.

The VDR data shall be downloadable by USB cable to a

computer using either Microsoft ™ or Apple ™ Operating

Systems using Class 1/ O.E.M. supplied reporting software.

17. BODY WIRING

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

a. All marker lights and reflectors must conform to the Provincial and Canadian Motor Vehicle Safety Standards (CMVSS) Regulations.

b. The electrical system shall include all panels, electrical components, switches and relays, wiring harnesses and other electrical components. The electrical equipment installed by the apparatus manufacturer shall conform to current automotive electrical system standards, the latest Federal DOT standards, and the requirements of the applicable NFPA 1901 standards.

c. The apparatus body shall have a Weldon V-MUX multiplexing system, to provide diagnostic capability. The system shall have the capability of delivering multiple signals via a CAN bus, utilizing specifications set forth by SAE J1939.

State location:

d. The electrical system shall be pre-wired for computer modem accessibility to allow service personnel to easily plug in a modem to allow remote diagnostics,

Page 25: REQUEST FOR PROPOSAL for ONE (1) RESCUE FIRE APPARATUS · SERVICE MANUAL SUPPORT As part of the standard delivery manual, the proponent shall give a password-protected link to the

NORTH MIDDLESEX FIRE DEPARTMENT SPECIFICATIONS RESCUE FIRE APPARATUS

SPECIFICATION DOCUMENT

Page 25 of 56

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

troubleshooting, or program additions. There shall be a diagnostic display provided in the cab.

e. The multiplexed system shall use twisted-pair shielded wire within the electrical system for noise reduction.

f. The diagnostic display shall allow for fault and condition messages to be displayed.

g. The networked system shall meet the following minimum requirement components:

• Power management centre

• Load shedding power management

• Solid-state circuitry

• Switch input capability

• Responsible for lighting device activation

• Self-contained diagnostic indicators

• Power distribution module

• Diagnostic display for warning message indication

• Driver Vista Screen

h. All wiring shall be stranded copper or copper alloy conductors of a gauge rated to carry 125 percent of the maximum current for which the protected circuit. Voltage drops in all wiring from the power source to the device shall not exceed 10 percent.

i. The wiring, wiring harness and insulation shall be in conformance to applicable SAE J-1128 with GXL temperature properties and NFPA standards.

j. All exposed wiring shall be protected in a loom with a minimum temperature rating of 289 degrees Fahrenheit. All wiring looms shall be properly supported and attached to body members.

k. The electrical conductors shall be constructed in accordance with applicable SAE standards.

l. Wiring connections shall use a method that provides a positive mechanical and electrical connection.

m. Electrical connections shall be with mechanical type fasteners and large rubber grommets where wiring passes through metal panels.

n. Wiring between the cab and body shall be joined using Deutsche type connectors or in an enclosed terminal junction panel and permit body removal with minimal impact on the apparatus electrical system.

o. Electrical junction or terminal boxes shall be weather resistant and located away from direct water spray. In addition, the main body junction panel shall house the automatically reset breakers and relays as required.

Page 26: REQUEST FOR PROPOSAL for ONE (1) RESCUE FIRE APPARATUS · SERVICE MANUAL SUPPORT As part of the standard delivery manual, the proponent shall give a password-protected link to the

NORTH MIDDLESEX FIRE DEPARTMENT SPECIFICATIONS RESCUE FIRE APPARATUS

SPECIFICATION DOCUMENT

Page 26 of 56

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

p. Exposed electrical cabling, harnesses, or terminal connections shall not be located in compartments, unless they are enclosed in an electrical junction box or covered with a removable electrical panel.

q. Wiring shall be uniquely identified at least every two feet (2') by colour coding or permanent marking with a circuit function code and identified on a reference chart or electrical wiring schematic per requirements of the applicable NFPA 1901 standards.

r. The electrical circuits shall be provided with low voltage over current protective devices. Such devices shall be accessible and located in required terminal connection locations or weather resistant enclosures. The over current protection shall be suitable for electrical equipment and shall be the automatic reset type and meet SAE standards.

s. All electrical equipment, switches, relays, terminals, and connectors shall have a direct current rating of 125 percent of the maximum current for which the protected circuit. The system shall have electro-magnetic interference suppression provided as required in applicable SAE standards.

t. The electrical system shall include the following: a) Electrical terminals in weather exposed areas shall have a non-conductive grease or spray applied. A corrosion preventative compound shall be applicable to all terminal plugs located outside of the cab or body. b) The electrical wiring shall be harnessed or be placed in a protective loom. c) Holes made in the roof shall be caulked with silicone. Large fender washers shall be used when fastening equipment to the underside of the cab roof. d) Any electrical component that is installed in an exposed area shall be mounted in a manner that will not allow moisture to accumulate. e) A coil of wire must be provided behind each electrical appliance to allow them to be pulled away from the mounting area for inspection and service work. f) All lights that have their sockets in a weather exposed area shall have corrosion preventative compound added to the socket terminal area.

u. A single warning light switch shall activate all required warning lights. This switch will allow the vehicle to respond to an emergency and "call for the right of way".

v. When the parking brake is applied, a "blocking right of

Page 27: REQUEST FOR PROPOSAL for ONE (1) RESCUE FIRE APPARATUS · SERVICE MANUAL SUPPORT As part of the standard delivery manual, the proponent shall give a password-protected link to the

NORTH MIDDLESEX FIRE DEPARTMENT SPECIFICATIONS RESCUE FIRE APPARATUS

SPECIFICATION DOCUMENT

Page 27 of 56

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

way" system shall be automatically activated per requirements of the NFPA 1901 standard. All clear warning lights shall be automatically turned off upon application of the parking brake.

w. The apparatus shall be electrically tested upon completion of the vehicle and prior to delivery. The electrical testing, certifications, and test results shall be submitted with the delivery documentation per requirements of the NFPA 1901 standard. The following minimum testing shall be completed by the apparatus manufacturer:

1. Reserve capacity test 2. Alternator performance test at idle 3. Alternator performance test at full load 4. Low voltage alarm test

x. The following documentation shall be provided on delivery of the apparatus: a. Documentation of the electrical system performance tests required above. b. A written load analysis, including: 1. The nameplate rating of the alternator. 2. The alternator rating under the conditions. 3. Each specified component load. 4. Individual intermittent loads.

y. Sufficient 110 V shore power and 110V generator/inverter power wiring shall be installed in the body compartment housing the refrigerator as described in 29 i.

z. One (1) automatic transfer switch shall be installed that allows components normally powered by the 120-volt shore power connection to be automatically powered by the on board generator upon start-up of the generator.

18. INTERIOR LIGHT & ACCESSORIES

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

a. Dome lights shall be provided at each cab door area. The lights shall include a dual red and white LED lamp. There shall be one (1) light centred over each of the Driver and Officer’s seat and two (2) lights centred in the rear passenger compartment. The clear lamp shall illuminate with the opening of each respective door with both the red and clear portions of the lamp activated by individual lighted switches on each lamp.

b. One (1) gooseneck map light controlled by an individual switch shall be supplied and mounted on the centre console.

Page 28: REQUEST FOR PROPOSAL for ONE (1) RESCUE FIRE APPARATUS · SERVICE MANUAL SUPPORT As part of the standard delivery manual, the proponent shall give a password-protected link to the

NORTH MIDDLESEX FIRE DEPARTMENT SPECIFICATIONS RESCUE FIRE APPARATUS

SPECIFICATION DOCUMENT

Page 28 of 56

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

c. All equipment compartments shall be provided with two (2) - LED strip type compartment lights one (1) on each side of door opening. The lights shall be the full height of the door opening and adequately illuminate the compartment for night time operation. One (1) proximity switch shall be installed and wired in each compartment door opening for the purposes of turning on the light when the door is opened.

19. EXTERIOR LIGHTS

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

a. The cab exterior lighting shall include halogen sealed headlights mounted in bright chrome bezels, amber LED marker lights shall be installed on the vehicle in conformance with the Canadian Motor Vehicle Safety Standard requirements (above windshield and on cab front side corners) and combination turn signal/parking lights in bright chrome bezels in accordance with Canadian Motor Vehicle Safety Standard requirements.

b. Two (2) Whelen M9LZC M9 Series light (or equivalent) with chrome flange shall be supplied on each side of the apparatus body. The lights shall be mounted so that they flood the area around the apparatus. Two (2) clearly labelled “LEFT SCENE LIGHT” and “RIGHT SCENE LIGHT” illuminated rocker switches with an "ON" indicator light shall be mounted in the switch panel and located in the cab.

State actual:

Page 29: REQUEST FOR PROPOSAL for ONE (1) RESCUE FIRE APPARATUS · SERVICE MANUAL SUPPORT As part of the standard delivery manual, the proponent shall give a password-protected link to the

NORTH MIDDLESEX FIRE DEPARTMENT SPECIFICATIONS RESCUE FIRE APPARATUS

SPECIFICATION DOCUMENT

Page 29 of 56

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

c. Two (2) Whelen M9LZC M9 Series scene light (or equivalent) with chrome flange shall be supplied on the rear of the apparatus body. The rear scene lights shall be mounted on the upper rear of the apparatus so that they flood the area behind the apparatus. A clearly labelled “REAR SCENE LIGHT” illuminated rocker switch with an “ON” indicator light shall be mounted in the switch panel and located in the cab.

The light shall also be wired to come on when the chassis is placed in reverse for added backup light illumination.

State actual:

d. Two (2) sealed, watertight 12 volt surface mount TecNiq E61-WS00-1 LED lights with polished stainless steel housings shall be installed. A high brightness, extreme environment spot and flood lamp shall project the main beam of light at a 60 degree angle from the mounting surface. A secondary, lower intensity light shall emit in a rectangular pattern over a wide angular range from the light.

The lights shall be located in the rear wheel well area, one each side, and shall automatically activate when the vehicle transmission is placed into reverse to assist with backing.

e. Four (4) LED cab step lights shall be supplied on each side of the chassis cab, two (2) lights per step. The step lights shall be located below the chassis cab doors and illuminate the chassis cab steps. All cab step lights shall automatically illuminate when the parking brake is applied.

State detail:

Page 30: REQUEST FOR PROPOSAL for ONE (1) RESCUE FIRE APPARATUS · SERVICE MANUAL SUPPORT As part of the standard delivery manual, the proponent shall give a password-protected link to the

NORTH MIDDLESEX FIRE DEPARTMENT SPECIFICATIONS RESCUE FIRE APPARATUS

SPECIFICATION DOCUMENT

Page 30 of 56

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

f. One (1) LED ground light shall be mounted under each cab chassis step. One (1) LED ground light shall be mounted under L1/R1. One (1) LED ground light shall be mounted under L2/R2. One (1) LED ground light shall be mounted under L4/R4. Two (2) LED ground lights shall be mounted under the rear tailboard. A minimum of twelve (12) ground lights are to be installed. All ground lights shall automatically illuminate when the parking brake is applied.

State detail:

g. A minimum of two (2) LED step lights at rear shall adequately illuminate the ladder used to access the top of the apparatus. Both step lights shall automatically illuminate when the parking brake is applied.

Page 31: REQUEST FOR PROPOSAL for ONE (1) RESCUE FIRE APPARATUS · SERVICE MANUAL SUPPORT As part of the standard delivery manual, the proponent shall give a password-protected link to the

NORTH MIDDLESEX FIRE DEPARTMENT SPECIFICATIONS RESCUE FIRE APPARATUS

SPECIFICATION DOCUMENT

Page 31 of 56

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

h. One (1) Knight 2, manufactured by Command Light, part number KL415A-FS, light tower shall be provided and installed on top of the body. The location of the light tower and its controls shall be installed according to instructions given by the customer and the requirements of the light tower manufacturer. The location of the light tower shall be towards the front portion of the apparatus body and shall be recessed to allow for protection when the light tower is in the nested position. The light tower shall extend 87-1/2" above the mounting surface and shall extend to full upright position in less than 15 seconds. The overall size of nested light tower shall be approximately 35" wide x 47" long x 13" high and weigh approximately 165 pounds. The electrically controlled unit shall not require usage of the vehicle's air supply for operation, thereby eliminating the chance for air leaks in the vehicle braking system. Hydraulic or pneumatic type floodlights are not acceptable alternatives to the specified all electric light tower. The light tower shall be tested to in wind conditions of 90 mph (150 kph) minimum. Other type floodlights that have not been tested to these conditions are not acceptable. The light tower shall be capable of overhanging the side or back of the vehicle to provide maximum illumination to the vicinity adjacent to the vehicle for the safety of emergency personnel in high traffic conditions. Any tower that is only capable of rotations at the top of a pole is not an acceptable alternative to the specified tower. The light tower shall be a two-stage articulating device with a lighting bank on top of the second stage capable of continuous 360 degree rotation. The light shall be elevated by electric linear actuators, one (1) actuator shall elevate the lower stage and one (1) actuator shall adjust the light bank angle from 0 to 110 degrees. Power for the light bank shall be supplied through power collecting rings thus allowing continuous 360 degree rotation in either direction.

Page 32: REQUEST FOR PROPOSAL for ONE (1) RESCUE FIRE APPARATUS · SERVICE MANUAL SUPPORT As part of the standard delivery manual, the proponent shall give a password-protected link to the

NORTH MIDDLESEX FIRE DEPARTMENT SPECIFICATIONS RESCUE FIRE APPARATUS

SPECIFICATION DOCUMENT

Page 32 of 56

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

The tower base shall have a light that illuminates the envelope of motion during any movement of the light tower mast as required by NFPA1901. The light tower shall be controlled with a hand-held 15 foot umbilical line remote control. The storage station for the remote control unit shall be equipped with a button to activate the "Auto-Park" automatic nesting feature. The controls on the remote box shall be: Two (2) switches, one (1) for each light bank. One (1) light bank rotation switch. One (1) switch for elevating lower and upper stage. One (1) indicator light to indicate when light bank is out of roof nest position. One (1) indicator light to indicate when light bank is rotated to proper nest position. The Command Light shall be equipped with the following bank of floodlights: Floodlight manufacturer: Fire Research Corp. Number of lamp heads: Six (6) FRC Spectra LED Voltage: 120 volt Watts of each lamp head: 220 watt Total watts of light tower: 1500 watts Amperage per lamp head: 2 amps Total amperage of light tower: 12 amps Total Lumens of light tower: 120,000 lumens Configuration: The light heads shall be mounted three (3) on each side of the light tower, giving two (2) vertical lines of three (3) when the lights are in the upright position. The controls for the light tower shall be mounted in the left front compartment.

i. One (1) backlight option shall be provided for the Command Light tower. The lower pair of light heads shall be capable of being rotated about a horizontal axis, providing light down on the vehicle or to the opposite side of the vehicle while four (4) lights remain pointed at the scene. The hand-held remote control shall have an additional switch supplied for the backlight rotation option.

Page 33: REQUEST FOR PROPOSAL for ONE (1) RESCUE FIRE APPARATUS · SERVICE MANUAL SUPPORT As part of the standard delivery manual, the proponent shall give a password-protected link to the

NORTH MIDDLESEX FIRE DEPARTMENT SPECIFICATIONS RESCUE FIRE APPARATUS

SPECIFICATION DOCUMENT

Page 33 of 56

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

j. M6 LED type red stop/tail lights shall be provided and mounted at the rear of the body.

M6 LED type amber directional signal lights with black arrows shall be provided and mounted at the rear of the body, one on each side on the rear and below the stop/tail lights.

M6 LED type clear backup lights shall be provided and mounted, one on each side at the rear of the body. The backup lights shall be mounted below the rear stop/tail and directional lights. One (1) pair of chrome plated taillight housings designed to hold four (4) Whelen M6 rear lights shall be provided.

The backup lights shall be activated when the transmission is placed in reverse.

k. Vehicle clearance marker lights with reflectors mounted in accordance with Canadian Motor Vehicle Safety Standard (C.M.V.S.S) shall be furnished and installed. All apparatus body marker lights shall be LED style lights.

l. A license plate mounting bracket shall be provided complete with a chrome plated shielded indirect type LED light. This bracket shall be mounted at the rear of the apparatus body.

m. The apparatus shall be equipped with the appropriate number, type of reflective devices located and mounted as required by the Canadian Motor Vehicle Safety Standard (C.M.V.S.S.).

20. WARNING DEVICES

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

a. Controls, switches and indicators shall be easily accessible and visible while the driver is in a seated position and the apparatus is in motion. The following instrumentation, controls and labels, over and above those provided by the manufacturer of the chassis, shall be mounted in the driving compartment as herein specified:

PTO generator controls

Master electrical load disconnect switch

Warning lights and siren switches

Auxiliary air horn switch.

Page 34: REQUEST FOR PROPOSAL for ONE (1) RESCUE FIRE APPARATUS · SERVICE MANUAL SUPPORT As part of the standard delivery manual, the proponent shall give a password-protected link to the

NORTH MIDDLESEX FIRE DEPARTMENT SPECIFICATIONS RESCUE FIRE APPARATUS

SPECIFICATION DOCUMENT

Page 34 of 56

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

b. The apparatus warning light panel shall be mounted in a location so that the driver may conveniently access the switches from a seated position with the apparatus in motion.

The panel shall include the following switches:

one (1) lighted master control switch to allow

for pre-selection of all emergency lighting

a sufficient number of lighted switches to

control all lighting and devices herein

specified.

c. Dual Grover Emergency Air Horns with chrome finish shall be mounted as follows:

one (1) on each front fender/hood area

d. Per NFPA standards, the successful proponent shall install an air pressure protection valve that prevents the use of air horns or other air operated accessories when the brake system air pressure drops below 80 psi.

e. A back-up alarm shall be supplied and the unit shall be installed so that it activates automatically when the vehicle is placed in reverse gear.

f. One (1) electronic siren, Whelen 295SLSA1 (or equivalent) complete with a microphone, shall be installed with the controls easily accessible to the driver from the seated position.

The siren shall be equipped with a remote mounted speaker Whelen SA315P 100 (or equivalent) mounted behind the front grill/bumper area.

Where siren and/or speaker models differ from above, state actual models

State actual: State actual:

g. One (1) 12 Volt “Screaming” Eagle Siren # C 9-11 F (Flange Mount) electro/mechanical coaster type siren shall be flush mounted in the front bumper apron. The 7”H x 11.50”L. Siren shall only draw 44 operational amps with a maximum momentary/peak amp draw of 95 amps.

h. A push button switch shall be incorporated into the manufactures steering wheel horn button to control the following warning devices;

Screaming Eagle siren

Dual Grover Emergency Air Horns

Standard road horn

Page 35: REQUEST FOR PROPOSAL for ONE (1) RESCUE FIRE APPARATUS · SERVICE MANUAL SUPPORT As part of the standard delivery manual, the proponent shall give a password-protected link to the

NORTH MIDDLESEX FIRE DEPARTMENT SPECIFICATIONS RESCUE FIRE APPARATUS

SPECIFICATION DOCUMENT

Page 35 of 56

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

The steering wheel horn button shall be controlled by a selector box that is installed with selections easily accessible to the driver from the seated position. The selections are to be labelled;

Eagle Siren

Air Horn

Road horn

One (1) rocker switch shall be installed on or near the selector box and shall serve as a Screaming Eagle siren brake.

i. All emergency lighting (type and installation) shall be in accordance with NFPA 1901. All emergency lighting must be LED. All lighting listed below is manufactured by Whelen. Where the proponent uses a different lighting package, state manufacturer for lights as listed below. Upper Level – Front Facing Lights (light bar 60”) -

Model # F4NOV LED

The light bar shall include a blue and red front facing

light on the driver’s side and two (2) red/red front facing

lights on the Officer’s side and two (2) white LED lights

in the middle (a total of 6 LED lights).

Upper Level Driver’s side – Side Facing Red – Front

and Rear of body.

Two (2) M9 c/w Chrome Trim

Upper Level Officer’s side - Side Facing Red – Front

and Rear of body.

Two (2) M9 c/w Chrome Trim

Upper Level Driver’s side – Rear Facing Red One (1) M9 c/w Chrome Trim Upper Level Officer side – Rear Facing Blue One (1) M9 c/w Chrome Trim Lower Level Driver’s side – Front facing Red light - One (1) located on hood grill – (1) M6RC M6 Series c/w Chrome Trim Lower Level Officer side – Front facing Blue light - One (1) located on hood grill – (1) M6RC M6 Series c/w Chrome Trim Lower Level – Zone B - One (1) located on side of hood

State actual: State actual: State actual: State actual: State actual: State actual: State actual:

Page 36: REQUEST FOR PROPOSAL for ONE (1) RESCUE FIRE APPARATUS · SERVICE MANUAL SUPPORT As part of the standard delivery manual, the proponent shall give a password-protected link to the

NORTH MIDDLESEX FIRE DEPARTMENT SPECIFICATIONS RESCUE FIRE APPARATUS

SPECIFICATION DOCUMENT

Page 36 of 56

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

forward of front wheel - (1) LINZ6R c/w Chrome Trim One (1) located forward of rear wheel and One (1) located rearward of rear wheel. Mounted in rub rail. (2) M2WR M2 Series c/w Chrome Trim Lower Level – Zone C – Two (2) located on rear of apparatus facing rearward – (1) M6RC M6 Series Enclosed in the chrome plated tail light housing 19.j Lower Level – Zone D - One (1) located on side of hood forward of front wheel - (1) LINZ6R c/w Chrome Trim One (1) located forward of rear wheel and One (1) located rearward of rear wheel. Mounted in rub rail (2) M2WR M2 Series c/w Chrome Trim

State actual: State actual: State actual: State actual:

j. There shall be a traffic advisor installed on the rear of the body. The light bar shall have a minimum of eight (8) amber LED light heads. One (1) Whelen TANF85 Linear Super LED 8 Head Traffic Advisor The light bar shall have a control panel located in the chassis cab. The control shall have the ability to provide for various flash patterns and shall incorporate a display to show the selected flash pattern on the control panel.

The traffic advisor shall activate in flash mode when the master switch is activated.

State actual:

21. RADIO SYSTEM

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

a. One (1) Motorola Turbo XPR4550 VHF Mobile radio complete with appropriate antenna shall be provided. Channel frequencies will be provided at time of pre­construction meetings.

b. One (1) external speaker is to be installed in a central location of the rear passenger compartment. The external speaker is to be connected to the mobile radio specified in 21 a.

22. RESERVED

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

Page 37: REQUEST FOR PROPOSAL for ONE (1) RESCUE FIRE APPARATUS · SERVICE MANUAL SUPPORT As part of the standard delivery manual, the proponent shall give a password-protected link to the

NORTH MIDDLESEX FIRE DEPARTMENT SPECIFICATIONS RESCUE FIRE APPARATUS

SPECIFICATION DOCUMENT

Page 37 of 56

23. GENERATOR

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

a. One (1) hydraulic PTO driven generator is to be installed on the apparatus. The generator is to be 10,000 Watts and capable of running all electrical equipment specified including the hydraulic Power unit specified in 30 a. and installed and tested in compliance with NFPA 1901(current edition) Chapter 22 standards and requirements. The generator shall be mounted on top of the apparatus in a location approved by the North Middlesex Fire Department as determined at the preconstruction meeting. The generator shall be easily separated into three major components (tray, cooler/fan assembly, and reservoir) for mounting in custom or remote locations on the apparatus. The installation of the generator shall be designed for continuous operation without overheating and undue stress on components. The generator tray assembly shall be delivered with the cooler/fan assembly mounted such that hot air is exhausted straight up, through an NFPA approved walking grate. The generator system shall consist of the following components;

Generator tray assembly which includes the generator, hydraulic motor, cooler, fan, Electronic Control Unit, 10 micron spin-on fluid filter and reservoir. The generator mounting base shall be constructed of a solid 3/8” thick 6061T6 extruded aluminium base plate.

Axial piston hydraulic pump with pressure compensated control;

Command and Control Center (CCC) display with all required wiring harnesses.

The generator tray assembly shall be delivered with the cooler/fan assembly mounted such that the hot air is exhausted straight up. An NFPA 1901 compliant extruded aluminium grate walking surface shall be installed on top of the entire generator tray assembly. The generator system shall be provided with a digital meter display in compliance with NFPA 1901 Chapter 22.4.6. The Command and Control Center (CCC) shall be an interactive operator control center, equipped with smart touch solid state buttons, with super bright red LERD displays for voltage, frequency, dual amperage displays , hour meter, service reminders, operator warnings, system faults and diagnostics. The electronics package shall include smart start engagement to reduce mechanical stress, precise voltage and frequency control, cold start system, automatic load and temperature compensation, integrated diagnostics system, and other automated control features to protect system, vehicle and operator. The CCC shall be permanently mounted at an operator’s panel, shall be located in a plane facing the operator, and

State detail:

Page 38: REQUEST FOR PROPOSAL for ONE (1) RESCUE FIRE APPARATUS · SERVICE MANUAL SUPPORT As part of the standard delivery manual, the proponent shall give a password-protected link to the

NORTH MIDDLESEX FIRE DEPARTMENT SPECIFICATIONS RESCUE FIRE APPARATUS

SPECIFICATION DOCUMENT

Page 38 of 56

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION shall be constructed in weatherproof integral enclosure/bezel. The generator system shall be equipped with diagnostic capabilities which are monitored by the operator through the Command and Control Center digital display meter panel. Diagnostics shall include overheat protection, system service reminders, low fluid indication, no PTO engagement indication, over-voltage, unbalanced loads, low 12volt voltage, and graduated high temperature displays. The output of the generator shall be controlled by an integral, patented, solid state Electronic Control Unit. The ECU shall be connected directly to the NFPA 1901 required digital instrumentation display. The generator shall be operable in the stationary mode OR when driving, utilizing the standard soft start system for engagement at any speed. The generator shall be engaged by a lighted control in the cab. The generator shall be tested in accordance with all current N.F.P.A. 1901 standards. All generator ratings and capacities shall be derived utilizing current NFPA 1901 testing parameters. The preferred generator is a Smart Power, model HR-8, 8000 watt hydraulic generator.

b. One (1) retractable cord reel containing 200 feet of minimum number 12/3 wire is to be installed in the body of the apparatus and to be accessible from both sides. The cord is to be yellow in colour and is to contain a minimum of four (4) 15 Amp female receptacles on the working end. The retractable cord reel is to be located as to be easily attached to the generator.

24. RESERVED

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

a. RESERVED

25. RESERVED

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

a. RESERVED

26. RESERVED

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

a. RESERVED

27. BODY

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

a. The body shall be constructed from 3/16” aluminium and State actual:

Page 39: REQUEST FOR PROPOSAL for ONE (1) RESCUE FIRE APPARATUS · SERVICE MANUAL SUPPORT As part of the standard delivery manual, the proponent shall give a password-protected link to the

NORTH MIDDLESEX FIRE DEPARTMENT SPECIFICATIONS RESCUE FIRE APPARATUS

SPECIFICATION DOCUMENT

Page 39 of 56

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION shall be a walk around style.

b. The body shall be between 17.5’ and 18.5’ in exterior dimension length. Body width shall be standard width. Body height shall be at equal height as chassis cab height.

State actual body dimensions Width: Height: Length:

c. An extruded aluminum channel rub rail shall be provided along the lower edge on both sides and the rear of the body. The rub rail shall be “set out” from the body by use of nylon spacers. The rub rail shall incorporate red and white reflective material along the vertical surface of the channel.

d. Two (2) collapsible wheel chocks shall be supplied and installed in easily accessible slide out mounts under the truck body in front of the rear wheels on the driver’s side of the apparatus.

State make and model;

e. A 12" deep rear step surface shall be provided at the rear of the apparatus body, bolted in place and easily removable for replacement or repair.

f. The rear wheel wells of the apparatus body are to be radius cut for a streamlined appearance.

g. A polished aluminium fenderette shall be furnished at each rear wheel well opening, held in place with concealed stainless steel fasteners.

h. Heavy duty black mud flaps shall be furnished and installed behind the rear wheels of the vehicle. Mud flaps shall extend the full width of each rear dual, and are to be attached to heavy angle support brackets with stainless steel fasteners. No Exceptions

i. Smooth aluminum shall be installed on the rear of the

body, to allow for the proper application and installation

of a "Chevron" stripe on the rear.

The entire rear portion of the body shall have 3M

diamond grade reflective red and yellow striping

installed. The chevron style striping shall be applied at a

45-degree upward angle pointing towards the center

upper portion of the rear panel.

j. The front of the body shall have aluminum checker plate

installed as to avoid stone chips on an otherwise

exposed front facing painted surface. The checker plate

shall be constructed of one continuous piece.

28. COMPARTMENT CONSTRUCTION

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

a. All compartment doors, unless otherwise stated, shall be roll up type doors. All doors shall have door ajar sensors integrated with the door ajar system. The preferred door manufacturers are Amdor or Rom Door.

State manufacture:

Page 40: REQUEST FOR PROPOSAL for ONE (1) RESCUE FIRE APPARATUS · SERVICE MANUAL SUPPORT As part of the standard delivery manual, the proponent shall give a password-protected link to the

NORTH MIDDLESEX FIRE DEPARTMENT SPECIFICATIONS RESCUE FIRE APPARATUS

SPECIFICATION DOCUMENT

Page 40 of 56

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

b. All compartments with storage facilities requiring a reach of greater than six foot (6’) six (6”) from ground level shall incorporate an integrated step that allows for easy, safe access to the top of the compartment.

State details:

c. Each roll up door shall incorporate an elastic nylon strap that is secured to the side wall of the interior compartment in a way that will allow the strap to contract automatically and tuck inside the compartment when closed to prevent the strap from dangling and hindering closing of the door. When the door is the open position, the strap shall be installed so that they are fully extended as to not interfere with removing items from the compartment. For the ease of locating, the strap shall be bright orange in colour.

State details:

d. Each roll up door shall be provided with an aluminum drip pan.

e. Unless otherwise stated, all roll up doors shall not be painted and left with their satin aluminum finish.

f. All compartments shall be provided with adequate drainage and louvers for ventilation. All louver openings shall be covered and filtered to prevent road dust from entering compartments. No Exception.

State details:

g. The tops of the compartments shall be provided with an aluminum drip molding installed above the doors to prevent water from entering the compartments.

h. Each compartment shall be provided with LED strips on both sides of compartment, mounted in protected locations and controlled by door ajar switches. Lights are to provide for total compartment illumination regardless of shelf location.

State actual:

i. The interior of the compartments shall be unpainted and have a natural aluminium finish.

State details:

j. Compartment floors and shelving floors shall be of a design to permit easy sweeping out of debris. As such, there shall be no raised lip at the opening of the compartment restricting the ease of cleaning or draining of water. All body compartment floors and shelving floors shall be protected with BLACK "Turtle Tiles" with the exception of those compartments with slide out trays.

State actual:

29. COMPARTMENT LAYOUT

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

Page 41: REQUEST FOR PROPOSAL for ONE (1) RESCUE FIRE APPARATUS · SERVICE MANUAL SUPPORT As part of the standard delivery manual, the proponent shall give a password-protected link to the

NORTH MIDDLESEX FIRE DEPARTMENT SPECIFICATIONS RESCUE FIRE APPARATUS

SPECIFICATION DOCUMENT

Page 41 of 56

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

a. All equipment listed in this section as well as any selected from the OPTIONS section 38 are to be stored in the body section of the apparatus. Items marked with an * are to have brackets and mounting hardware or other storage solutions supplied (not installed) by the vendor. The following equipment list is existing loose equipment that will be stowed in the body section of the apparatus and is listed in geographic groupings of where the equipment is to be mounted as determined by the left hand FUNCTION column. This list of equipment is not to be supplied by the vendor.

FUN

CTI

ON

DES

CR

IPTI

ON

DIM

ENSI

ON

(i

nch

es)

WEI

GH

T

(po

un

ds)

Medical Trauma Bag 24x20x16 29

Medical Defibrillator 10x12x8 8

*Extinguisher 20 lb ABC Extinguisher

10x10x24 37

*Extinguisher 20 lb ABC Extinguisher

10x10x24 37

*Extinguisher 2.5 gal. Class A Extinguisher

16x24x9 20

*Extinguisher 2.5 gal. Class A Extinguisher

16x24x9 20

Power Tools Vent Saw 28x9x10 20

Power Tools Quick Cut Saw 30x10x12 27

Power Tools 4 L Echo Chain Oil 5x8x12 5

Power Tools Gasoline Can 10x7x14 17

Power Tools Gasoline Can 10x7x14 17

Power Tools Hydraulic Hoses (Spare)

24x24x16 36

Cribbing Crate of Cribbing (x5)

13x13x19 175

Cribbing Cribbing (x11) 6x6x24 154

Cribbing Cribbing (x5) 4x4x24 25

Cribbing Step Cribbing (Large) (x2)

6x31x10 42

Cribbing Step Cribbing (Small)

6x24x8 8

Page 42: REQUEST FOR PROPOSAL for ONE (1) RESCUE FIRE APPARATUS · SERVICE MANUAL SUPPORT As part of the standard delivery manual, the proponent shall give a password-protected link to the

NORTH MIDDLESEX FIRE DEPARTMENT SPECIFICATIONS RESCUE FIRE APPARATUS

SPECIFICATION DOCUMENT

Page 42 of 56

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

*Extrication Tools

Hurst Cutters (S510)

10x35x7 38

*Extrication Tools

Hurst Spreaders (Sp310)

10x31x8 44

*Extrication Tools

Hurst Ram (R424) 8x24x5 44

*Extrication Tools

Power Pack 17x19x20 120

Extrication Support

Rescue 42 Stabilizers (x4)

8x12x44 120

Extrication Support

Ram Support 8x19x12 66

Extrication Support

Rescue 42 Strap Bag

20x12x11 25

Extrication Support

Rescue 42 Access Bag

30x13x13 57

Extrication Support

Pneumatic Lift Bags (Set of 3 + kit)

21x20x12 65

Extrication Support

Bottle Jacks (x2) 7x7x9 46

Extrication Support

Air Chisel 16x11x5 30

Extrication Support

Saw-Z-All (Tiger Saw)

24x9x5 22

Extrication Support

Combi Tool (Manual)

26x22x10 23

Extrication Support

Glass Master Saw (x2)

30x6x1 10

Extrication Support

Come-Along Box 32x9x10 93

Extrication Support

Air Operated Ram & Spreader

25x15x10 78

*Forcible Entry

Halligan Tool (x3) 30x6x5 30

*Forcible Entry

Sledge Hammer 3x7x36 10

*Forcible Entry

Pry Bar (x3) 4x7x42 51

*Forcible Entry

Bolt Cutters (x3) 2x6x36 45

Forcible Entry Hacksaws (x3) 18x4x1 6

*Forcible Entry

Axe 2x12x36 10

Page 43: REQUEST FOR PROPOSAL for ONE (1) RESCUE FIRE APPARATUS · SERVICE MANUAL SUPPORT As part of the standard delivery manual, the proponent shall give a password-protected link to the

NORTH MIDDLESEX FIRE DEPARTMENT SPECIFICATIONS RESCUE FIRE APPARATUS

SPECIFICATION DOCUMENT

Page 43 of 56

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

*Forcible Entry

Pike Poles (x2) 3x2x36 10

*SCBA SCBA Packs (x4) 21x9x25 100

Electrical PPV Fan 18x18x36 70

*Electrical 50' Extension Cords (x2)

12x3x36 10

Tool Boxes Tool Box 19x6x7 14

Tool Boxes Imperial Tool Set 20x10x5 22

Tool Boxes Metric Tool Set 17x10x3 12

Scene Management

Accountability Case 40x17x10 55

Scene Management

Pylons (x12) 14x14x30 60

Rope Rescue Equipment

Harness (x8) 10x6x40 64

Rope Rescue Equipment

Rope Rescue Access

23x17x10 20

Rope Rescue Equipment

Rope Rescue Access

20x8x14 10

Rope Rescue Equipment

Rope Bags (Yellow) (x4)

13x13x22 80

Rope Rescue Equipment

Tag Line Bags (Red) (x2)

9x9x22 20

Rope Rescue Equipment

300' Safety Rope Bag

14x14x30 40

Rope Rescue Equipment

Utility Rope Bag 11x11x22 15

Rope Rescue Equipment

Block & Tackle Bag 11x11x20 15

Rope Rescue Equipment

Anchor Strap Bag 12x7x20 20

Rope Rescue Equipment

Trauma Bag 14x10x24 20

*Rope Rescue Equipment

Stokes Basket 82x25x8 32

*Rope Rescue Equipment

Backboards (x2) 73x17x2 40

Rope Rescue Equipment

Blankets 24x24x16 20

Rope Rescue Equipment

Emergency Blanket 24x12x4 5

Page 44: REQUEST FOR PROPOSAL for ONE (1) RESCUE FIRE APPARATUS · SERVICE MANUAL SUPPORT As part of the standard delivery manual, the proponent shall give a password-protected link to the

NORTH MIDDLESEX FIRE DEPARTMENT SPECIFICATIONS RESCUE FIRE APPARATUS

SPECIFICATION DOCUMENT

Page 44 of 56

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

Rope Rescue Equipment

Cocoon Stretcher 14x14x40 30

Rope Rescue Equipment

Rescue Helmet (x10)

11x14x8 50

Haz Mat Pail of absorbent 13x13x24 70

Haz Mat Spill Kit 18x14x10 15

*Air Cylinders Aluminium (x5) 7x7x24 105

*Air Cylinders Carbon Fibre (x19) 7x7x24 228

*Utility Brooms (x6) & Shovels (x9)

N/A N/A

Utility Caution Tape, Duct Tape, Detectors

N/A 10

b. Where aluminium slide out trays / vertical tool boards are installed, Slide Master are preferred. The slide-out tray shall have a minimum capacity of 600 pounds. Capacity rating shall be in the extended position. Trays to be supplied with chevron reflective striping and Turtle Tiles. Automatic locks shall be provided for both the "in" and "out" positions. The trip mechanism for it shall be located at the front of the tray for ease of use with a gloved hand.

State detail:

c. Compartments L1, L2, R1 and R2 are to be designed and fabricated to the same width as to facilitate the interchanging of adjustable shelving.

State detail:

d. Compartments L4 and R4 are to be designed and fabricated to the same width as to facilitate the interchanging of adjustable shelving.

State detail:

e. The rearward compartments (L4, R4 and B1) are to be independent of any other compartment.

State detail

f. The left side and right side forward and mid compartments (L1, L2, L3, R1, R2 and R3) shall be transverse.

State detail:

g. The over the wheel compartments (L3 and R3) shall be used to store 24 SCBA air cylinders and four (4) self- contained breathing apparatus (SCBA), mounted on slide out tool boards to facilitate easy donning of the SCBA. These transverse compartments shall also store two (2) backboards as described in 29 a.

State detail:

Page 45: REQUEST FOR PROPOSAL for ONE (1) RESCUE FIRE APPARATUS · SERVICE MANUAL SUPPORT As part of the standard delivery manual, the proponent shall give a password-protected link to the

NORTH MIDDLESEX FIRE DEPARTMENT SPECIFICATIONS RESCUE FIRE APPARATUS

SPECIFICATION DOCUMENT

Page 45 of 56

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

h. The bidder shall allow for; Ten (10) slide out trays Five (5) pull-out trays Four (4) adjustable shelves Two (2) adjustable dividers With placement to be determined at pre-construction.

State detail:

i. One (1) compartment suitable for housing a refrigerator shall be designed. The compartment shall have free space of 24” wide, 24” deep and 36” high and shall have adjacent storage for other rehabilitation supplies such as two (2) cases of bottled drinking water. The compartment shall also have electrical capabilities as described in 17 y.

State detail:

j. One (1) absorbent storage hopper bin shall be provided

and located on the right side in the rear wheel well of the

apparatus body ahead of the rear wheels. The bin shall be

a water tight design, incorporating a lid and designed to

slide out from its stowed position for easy filling. The bin

shall have a gate type valve installed at the bottom to

allow for the filling of a pail. The hopper shall be

installed to accommodate the filling of a standard 5

gallon pail when located on flat ground under the hopper.

State detail:

30. HYDRAULICS

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

a. One (1) 220 Volt Hurst Quad P650-4E (275780000) Hydraulic Power Unit is to be installed in an appropriate body compartment.

b. Three (3) retractable electric hydraulic hose reels containing 100 feet of high pressure 10,000 psi hose each are to be installed in the body area of the apparatus and are to be accessible from both sides of the apparatus and located as to be easily plumbed to the Hydraulic Power Unit specified in 30 a.

c. Three (3) high pressure hydraulic hose pony lengths are to be installed. One (1) pony length of ten (10) feet of high pressure 10,000 psi hose is to be affixed at the end of each retractable hydraulic hose reel where the connection is to be made to the hydraulic tool.

31. RESERVED

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

a. RESERVED

Page 46: REQUEST FOR PROPOSAL for ONE (1) RESCUE FIRE APPARATUS · SERVICE MANUAL SUPPORT As part of the standard delivery manual, the proponent shall give a password-protected link to the

NORTH MIDDLESEX FIRE DEPARTMENT SPECIFICATIONS RESCUE FIRE APPARATUS

SPECIFICATION DOCUMENT

Page 46 of 56

32. STEPS & HANDRAILS

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

a. Steps and handrails shall be provided at any location where a firefighter may need to climb on the apparatus. All steps and handrails shall provide for a standard three (3) points of contact for persons climbing on the apparatus. NO EXCEPTIONS.

State locations:

b. The cab shall have aluminium grab handles at each door position. The aluminium shall be bright anodized for long service. Moulded rubber gaskets shall be installed under the grab handles to protect the painted surface of the cab.

c. The right side of the Freightliner 4-door chassis shall be equipped with a modular step constructed from slip resistant aluminum tread plate to conform with applicable NFPA standards. The entire step is to be of a one piece design, bolted in place for ease of removal. Heavy steel supports shall be provided to support the right and left side cab entrance steps. The steps are to be enclosed and to have a similar appearance to the step/fuel tank enclosure provided on the left side. Supports shall be attached directly to the chassis frame rails, and shall provide adequate support to the steps to minimize flex and distortion. The overlay shall be provided with a storage compartment intended to store passenger firefighting helmets and other items as space may provide. Helmet brackets shall be provided and installed by the vendor as to make maximum use of this space. A hinged weather tight door with latch shall be provided on the storage compartment. The preferred number of helmets to store between the right side and left side step overlay is a maximum of five (5).

State details, include helmet storage design and quantity:

Page 47: REQUEST FOR PROPOSAL for ONE (1) RESCUE FIRE APPARATUS · SERVICE MANUAL SUPPORT As part of the standard delivery manual, the proponent shall give a password-protected link to the

NORTH MIDDLESEX FIRE DEPARTMENT SPECIFICATIONS RESCUE FIRE APPARATUS

SPECIFICATION DOCUMENT

Page 47 of 56

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

d. The left side of the Freightliner 4-door chassis shall be equipped with a modular step/fuel tank enclosure constructed from slip resistant aluminum tread plate to conform with applicable NFPA standards. The step/enclosure is to completely cover the fuel tank, and is to include a radius cut-out allowing access to the fuel tank fill. The entire step/enclosure is to be of a one piece design, bolted in place for ease of removal. Heavy steel supports shall be provided to support the right and left side cab entrance steps. Supports shall be attached directly to the chassis frame rails, and shall provide adequate support to the steps to minimize flex and distortion. The overlay shall be provided with a storage compartment intended to store passenger firefighting helmets and other items as space may provide. Helmet brackets shall be provided and installed by the vendor as to make maximum use of this space. A hinged weather tight door with latch shall be provided on the storage compartment. The preferred number of helmets to store between the right side and left side step overlay is a maximum of five (5).

State details, include helmet storage design and quantity:

Page 48: REQUEST FOR PROPOSAL for ONE (1) RESCUE FIRE APPARATUS · SERVICE MANUAL SUPPORT As part of the standard delivery manual, the proponent shall give a password-protected link to the

NORTH MIDDLESEX FIRE DEPARTMENT SPECIFICATIONS RESCUE FIRE APPARATUS

SPECIFICATION DOCUMENT

Page 48 of 56

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

e. Steps, platforms, or permanently affixed ladders shall be provided, as necessary, to permit firefighters to access all working and storage areas of the apparatus. There will be no exception to this and details will be discussed at a pre-assembly meeting. When such items are utilized, the maximum stepping height shall not exceed 18”, with the exception of the first step to the ground which shall not exceed 24”.

Platforms or secure ladders shall be provided

where the ground to the first step, platform, or

ladder exceeds 24”. The ground to the first step

shall be determined with the apparatus on level

ground.

All steps shall have a minimum surface area of

35 square inches, shall be of such a shape that a

5” diameter disk does not overlap any side when

placed on the step, and shall be arranged to

provide at least 8” of clearance between the

leading edge of the step and any obstruction.

All steps, platforms, or ladders shall sustain a

minimum static load of 500 pounds without

deformation.

A label shall be located on the vehicle at the

step areas warning personnel that riding in or on

these areas while the vehicle is in motion is

prohibited.

State details:

Page 49: REQUEST FOR PROPOSAL for ONE (1) RESCUE FIRE APPARATUS · SERVICE MANUAL SUPPORT As part of the standard delivery manual, the proponent shall give a password-protected link to the

NORTH MIDDLESEX FIRE DEPARTMENT SPECIFICATIONS RESCUE FIRE APPARATUS

SPECIFICATION DOCUMENT

Page 49 of 56

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

f. Handrails shall be supplied to assist fire fighters whenever they are expected to climb on or onto the apparatus and a ladder is not supplied. There will be no exception to this and details will be discussed at a pre-assembly meeting. NFPA approved, extruded aluminium ribbed finish "non-slip" access rails with chrome plated mounting brackets shall be provided. Smooth access rails or rails having an adhesive or rubber covering that can loosen over time are unacceptable. Handrails shall be fabricated from 1 ¼” diameter anodized aluminium extrusions, with a ribbed design, to provide a positive gripping surface. Handrails shall have a clearance of at least 2” between the handrail and any surface. Rubber gaskets shall be installed below each handrail bracket to prevent cracking or fracturing of the painted surface. Drain holes shall be provided in the bottom of all vertically mounted handrails.

State details:

g. There shall be a swing out and down access ladder supplied and installed on the rear of the apparatus, for accessing the top of the apparatus. It shall be of an all-aluminum design and shall incorporate treads 6" deep and no more than 18" apart. The ground to the first step dimension, on level ground, shall be no more than 18". When in the deployed position the ladder shall have an angle of approximately 75-degrees to facilitate ascending and descending the ladder. The ladder shall be retained in the stowed and deployed position by two (2) gas cylinders and shall not require the use of latches to hold it in position. The ladder shall be used to access the generator as described in 23 a.

33. PAINT, FINISH & LETTERING

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

a. All removable items, i.e.: brackets, lights, mirrors, etc. shall be painted separately or removed to insure finish paint behind mounted items. Body components that cannot be finish painted upon assembly shall be finished before assembly.

Page 50: REQUEST FOR PROPOSAL for ONE (1) RESCUE FIRE APPARATUS · SERVICE MANUAL SUPPORT As part of the standard delivery manual, the proponent shall give a password-protected link to the

NORTH MIDDLESEX FIRE DEPARTMENT SPECIFICATIONS RESCUE FIRE APPARATUS

SPECIFICATION DOCUMENT

Page 50 of 56

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

b. A reflective trim and lettering package shall be installed to the specifications of the North Middlesex Fire Department. The exact details will be discussed at a pre-construction meeting. The following outlines the basic requirements.

c. There shall be a reflective stripe running the full length of the apparatus on both sides. The stripe shall incorporate a large scrolling “Z” pattern. The stripe shall be one (1) 4” and two (2) 1”white 3M reflective material. The Municipality of North Middlesex Logo shall be overlaid in the 4” portion on the rear of the body on both sides.

d. The front cab doors shall have the North Middlesex Fire Department crest applied and include the word “Parkhill” in the lower portion of the door below the crest.

e. A graphic of a telephone receiver over the numbers “911” shall be provided on both rear side roll up doors. The graphic shall be roughly 10” in height. The graphic shall be done with white 3M Diamond Grade reflective material.

f. On either side of the hood, above the fender area, the word “RESCUE” shall be lettered with 4” small engine turn gold and black shadowing.

g. The left and right sides of the body (above compartment doors) shall be provided with a slogan done in 5” small engine turn gold with black shadowing. The verbiage shall read “SMOKE AND CO ALARMS SAVE LIVES”.

h. The left and right sides of the body (above compartment doors) shall be provided with a flowing Canadian Flag. The flag shall be located between the upper level driver’s and officer’s side warning lights as described in 20 i and the slogan as described in 33 g. The exact flag graphic shall be approved by the North Middlesex Fire Department at a pre-construction meeting.

i. The entire rear portion of the body shall have 3M Diamond Grade reflective red and yellow Chevron striping installed as required by NFPA 1901.

j. The apparatus body and chassis cab shall be painted to match the colour of the apparatus body.

k. The cab/body paint colour shall be Red

A colour chip or equivalent sample shall be provided to successful proponent at a pre-construction meeting.

The final finish of the cab shall be to fire apparatus standards; exhibiting excellent gloss durability and colour retention properties.

Page 51: REQUEST FOR PROPOSAL for ONE (1) RESCUE FIRE APPARATUS · SERVICE MANUAL SUPPORT As part of the standard delivery manual, the proponent shall give a password-protected link to the

NORTH MIDDLESEX FIRE DEPARTMENT SPECIFICATIONS RESCUE FIRE APPARATUS

SPECIFICATION DOCUMENT

Page 51 of 56

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

l. Preparation of the painted components, including pre-clean and pre-treat shall be in accordance with the paint manufactures specified guidelines.

The apparatus body and all other painted components shall be primed with a primer specified by the paint manufacturer and in accordance with their accepted guidelines.

m. The colour coat application shall be acrylic urethane. The final finish shall be free of dirt and sags and shall meet a minimum grade of 5 when compared to the "ACT" general orange peel standards by "ACT" Laboratories, Inc. of Hillsdale, MI.

n. All seams shall be caulked both inside and along the exterior edges with an automotive sealant to prevent moisture from entering between any body panels.

Once construction of the body and all parts have been completed, compartment doors, shelves, rub rails, running boards kick plates, overlays, handrails, lights, and all other parts are to be removed.

Tacked free of any dust particles, the body and all parts shall be individually sprayed to inhibit corrosion and provide lasting adhesion.

While constructing the truck body, all parts shall be properly fitted on the body and then removed. The backside of all parts shall be sanded smooth of any burrs and sharp edges.

During reassembly of the apparatus, care shall be exercised in fitting and fastening the parts back in their respective position on the vehicle.

o. One (1) quart of touch-up paint shall be furnished with the truck.

34. APPARATUS TESTING

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

a. All applicable tests as outlined under the latest edition of NFPA 1901 shall be performed on the finished apparatus.

b. All applicable tests as outlined under the latest edition of CAN/ULC S515-13 shall be performed on the finished apparatus.

c. Written certificates/documentation detailing the results of all testing shall be provided with the finished apparatus.

Page 52: REQUEST FOR PROPOSAL for ONE (1) RESCUE FIRE APPARATUS · SERVICE MANUAL SUPPORT As part of the standard delivery manual, the proponent shall give a password-protected link to the

NORTH MIDDLESEX FIRE DEPARTMENT SPECIFICATIONS RESCUE FIRE APPARATUS

SPECIFICATION DOCUMENT

Page 52 of 56

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

d. The apparatus, prior to acceptance, will be required to meet the vehicle stability of the applicable NFPA Automotive Fire Apparatus Standard. A calculated center of gravity shall be provided. The calculated or measured center of gravity (CG) shall be no higher that 80-percent of the rear axle track width.

State detail:

35. WARRANTY & SERVICE

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

a. The chassis frame shall carry a Non-Pro Rated lifetime warranty. Provide actual warranty coverage with proposal.

State warranty details:

b. The manufacturer shall warrant the entire hydraulic PTO driven generator system, as described in 23 a., including the Command and Control Center (CCC) digital meter display for a period of 6 year or 1,000 hours. Provide actual warranty coverage with proposal.

State warranty details:

c. The manufacturer shall warrant the 220 Volt Hurst Quad P650-4G Hydraulic Power Unit as specified in 30 a., for a minimum period of ten (10) years. Warranty to be Non-Pro Rated. Provide actual warranty coverage with proposal.

State warranty details:

d. The manufacturer shall warrant the Light Tower, as specified in 19 h. or 38 a. for a minimum period of five (5) years.

State warranty details:

e. Unless otherwise stated equipment selected from the Options section shall carry the manufactures standard warranty for the specified equipment.

State warranty details:

f. Warranties shall begin on the in-service date as reported by the North Middlesex Fire Department. No Exception.

g. The manufacturer shall warrant the Acrylic Urethane finish for a period of ten (10) years from its date of delivery. The warranty shall be Non-Pro Rated and shall cover 100% of the cost of the warranty repairs and shall include, but not be limited to, adhesion, blistering,

bubbling, corrosion, cracking, gloss or colour retention.

Provide actual warranty coverage with proposal.

State warranty details:

h. The manufacturer shall warranty the modular body structure for a period of at least ten (10) years. This warranty shall be Non Pro-Rated. Provide actual warranty coverage with proposal.

State warranty details:

i. The manufacturer shall warranty the apparatus, bumper to bumper for a one (1) year period. This warranty shall be Non-Pro Rated and shall include the vehicle's electrical system and components as well as workmanship defects. Provide actual warranty coverage with proposal.

State warranty details:

Page 53: REQUEST FOR PROPOSAL for ONE (1) RESCUE FIRE APPARATUS · SERVICE MANUAL SUPPORT As part of the standard delivery manual, the proponent shall give a password-protected link to the

NORTH MIDDLESEX FIRE DEPARTMENT SPECIFICATIONS RESCUE FIRE APPARATUS

SPECIFICATION DOCUMENT

Page 53 of 56

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

j. Within one (1) business day after receipt of a verbal or written notification that warranty and or service contract work is required, the successful proponent shall respond verbally, and immediately follow up by letter to the Municipality with a statement of intent to show where and when the warranty service shall be accomplished.

k. Proponents shall state the location of the fire truck manufacturer's nearest service facility and parts depot to the Municipality’s location.

Company Name: Address: Phone: Fax: E-mail:

l. State actual additional warranties or logistical services that the proponent might provide above and beyond the requirements of these specifications.

State detail:

36. DELIVERY

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

a. The successful proponent shall deliver the vehicle under its own power to the North Middlesex Fire Department as outlined in the Information section #16 and #17. All documents necessary for licensing shall be completed prior to delivery and the vehicle shall be delivered, licenced and registered to the Municipality of North Middlesex.

If cost reduction is possible through the North Middlesex Fire Department taking part in the delivery of the vehicle, proponents should state options for such arrangements.

Vehicle will be delivered complete to specifications within days of date ordered. State delivery cost reduction options:

37. LOOSE EQUIPMENT

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

a. The list of equipment in this section shall be supplied by the vendor with appropriate brackets and mounting hardware or other storage solutions (not vendor installed unless stated otherwise).

b. Folding wheel chocks and brackets as described in 27 d. (Installed by vendor)

Page 54: REQUEST FOR PROPOSAL for ONE (1) RESCUE FIRE APPARATUS · SERVICE MANUAL SUPPORT As part of the standard delivery manual, the proponent shall give a password-protected link to the

NORTH MIDDLESEX FIRE DEPARTMENT SPECIFICATIONS RESCUE FIRE APPARATUS

SPECIFICATION DOCUMENT

Page 54 of 56

DETAILED DESCRIPTION YES NO SPECIFICATION/VARIATION

c. Two (2) portable, rechargeable scene lights with approximately 3,600 Lumens. The preferred light is a Streamlight. The lights will be stored in a compartment with shoreline power. Exact location to be determined at a pre-construction meeting.

State manufacturer and type:

38. OPTIONS

Please indicate the amount of dollar additions or savings for each of listed options below.

DETAILED DESCRIPTION YES NO Additional cost/savings

Page 55: REQUEST FOR PROPOSAL for ONE (1) RESCUE FIRE APPARATUS · SERVICE MANUAL SUPPORT As part of the standard delivery manual, the proponent shall give a password-protected link to the

NORTH MIDDLESEX FIRE DEPARTMENT SPECIFICATIONS RESCUE FIRE APPARATUS

SPECIFICATION DOCUMENT

Page 55 of 56

Please indicate the amount of dollar additions or savings for each of listed options below.

DETAILED DESCRIPTION YES NO Additional cost/savings

a. One (1) Hurst eDraulics Spreader SP 555E2 (28.7”) (271555000) is to be supplied. One (1) Hurst eDarulics Cutter S 700E2 (272085000) is to be supplied. One (1) Hurst eDraulics Ram R 421E2 (53”) (274085000) is to be supplied. One (1) Hurst eDraulics 110V Adapter (272085412) is to be supplied. One (1) 3000 watt (25.0 Amperes), 120/240-volt portable generator/inverter shall be provided for on the apparatus. The generator shall have approximate dimensions of 26.8" L x 17.5" W x 21.9" H and a dry weight of 136 pounds. The preferred generator is a Yamaha EF3000iS or comparable Honda product. A properly ventilated compartment shall be provided for the generator and include a slide out tray. One (1) 12 gauge 100 foot extension cord, yellow in colour. One (1) 12 gauge 50 foot extension cord, yellow in colour. One (1) 12 gauge 25 foot extension cord, yellow in colour. One (1) DC to AC power inverter system with a 30-amp AC automatic transfer switch furnished on the apparatus. The shore power shall be connected to the system AC output receptacle to supply power to the AC loads. When the vehicle is underway and the shoreline power is disconnected, the automatic transfer switch connects the AC output receptacle to the power inverter that obtains power from the 12-volt battery system. The preferred Inverter is a Vanner model IQC12-2600 AC. When the shoreline is disconnected all shoreline outlets will be transferred and run through the inverter including the load as described in 17 y. One (1) Command Light KL409D-H4 light tower shall be provided and installed on top of the body. The location of the light tower and its controls shall be installed according to the customer and the requirements of the light tower manufacturer. The location of the light tower shall be towards the front portion of the apparatus body and shall be recessed to allow for protection when the light tower is in the nested position. The umbilical line remote control for the light tower shall be conveniently located in compartments L1 or L2. The light tower shall include the backlighting option. The high idle switch described in 4 f. shall be programmed to activate when the light tower is in use.

State cost: State cost: State cost: State cost: State cost: State cost: State cost: State cost: State cost: State cost:

Page 56: REQUEST FOR PROPOSAL for ONE (1) RESCUE FIRE APPARATUS · SERVICE MANUAL SUPPORT As part of the standard delivery manual, the proponent shall give a password-protected link to the

NORTH MIDDLESEX FIRE DEPARTMENT SPECIFICATIONS RESCUE FIRE APPARATUS

SPECIFICATION DOCUMENT

Page 56 of 56

Please indicate the amount of dollar additions or savings for each of listed options below.

DETAILED DESCRIPTION YES NO Additional cost/savings

b. Remove one (1) 220 Volt Hurst Quad P650-4E (275780000) Hydraulic Power Unit installed in a body compartment as described in 30 a. Remove three (3) retractable hydraulic hose reels containing 100 feet of high pressure 10,000 psi hose as described in 30 b. Remove three (3) high pressure hydraulic hose pony lengths as described in 30 c. Remove one (1) 10,000 Watt hydraulic PTO driven generator as described in 23 a. Remove one (1) PTO generator control as described in 20 a. Remove one (1) ladder as described in 32 g. Remove the ladder lighting as described in 19 g. Remove one (1) retractable cord reel as described in 23 b. Remove one (1) Knight 2, manufactured by Command Light, part number KL415A-FS, light tower as described in 19 h. Remove one (1) Command Light backlight as described in 19 i. Remove one (1) Automatic Transfer switch described in 17 z.

Sate cost reduction: Sate cost reduction: Sate cost reduction: Sate cost reduction: Sate cost reduction: Sate cost reduction: Sate cost reduction: Sate cost reduction: Sate cost reduction: Sate cost reduction: Sate cost reduction:

c. Two (2) tone cab chassis paint. Black on red. Paint break to be determined at pre-construction meeting.

State cost:

d. The apparatus passenger and driver side fender area around the outer rear wheel wells shall be fabricated with aluminium checker plate.

State cost:

e. In regards to the compartment finish as described in 28 i. Change the natural aluminium finish to a swirl application finish.

State cost: