Report for 15 Hay Street Development, Box Hill · Report for 15 Hay Street Development, Box Hill...
Transcript of Report for 15 Hay Street Development, Box Hill · Report for 15 Hay Street Development, Box Hill...
Canaan Holdings Pty Ltd
Report for 15 Hay Street Development, Box Hill
Buffer Assessment
June 2012
31/28957/210231 15 Hay Street Development, Box Hill Buffer Assessment
Contents
1. Introduction 1
1.1 Scope of Works 1
2. Project Description and Understanding 2
2.1 Project Description 2
2.2 Surrounding Industries 3
2.3 Complaint History 5
3. Surrounding Industry Operations 10
3.1 SCA Hygiene Australia 10
3.2 Cementaid 10
3.3 K&J Printing 10
3.4 Alexander’s Industrial Laundry 10
3.5 Allan Industries 11
3.6 Burdett Engineering 11
3.7 Maton Guitar Factory 11
3.8 Wheelers Quality Cabinets 11
3.9 Auto Repair Centres 12
4. Relevant Buffer Guidelines 13
4.1 EPA Buffer Guidelines 13
4.2 Default and Recommended Buffers from Surrounding Industries 13
4.3 Application of a Buffer to 15 Hay Street 17
5. Meteorology 18
5.1 Wind Pattern 18
5.2 Pattern of Atmospheric Stability 22
6. Directionally-Dependant Buffer 25
6.1 Directionally-Dependant Buffer for Existing Industries 25
6.2 Updated Appropriate Buffer for Proposed Development at 15
Hay Street 28
7. Conclusions 29
8. Limitations 30
31/28957/210231 15 Hay Street Development, Box Hill Buffer Assessment
Table Index Table 4-1 Default and Recommended Buffers for Existing
Surrounding Industries 15
Table 6-1 Directional Variation in Buffer using Local Meteorology – Box Hill 2008. 26
Figure Index Figure 2-1 Site Aerial 6
Figure 2-2 Development Plan 7
Figure 2-3 Planning Scheme Map 8
Figure 2-4 Surrounding Industries 9
Figure 4-1 Default EPA Buffers 16
Figure 5-1 Annual Wind Rose for Box Hill 2008 19
Figure 5-2 Seasonal Wind Roses for Box Hill 2008 21
Figure 5-3 Annual Stability Rose for Box Hill 2008 23
Figure 5-4 Seasonal Stability Roses for Box Hill 2008 24
Figure 6-1 Directionally Dependent Buffer 27
1
31/28957/210231 15 Hay Street Development, Box Hill Buffer Assessment
1. Introduction
Canaan Holdings Pty Ltd (Canaan Holdings) is planning a new residential development at 15 Hay Street
Box Hill South, 15 km east of Melbourne. GHD was engaged by Canaan Holdings to identify any
potential buffer constraints imposed on the subject site as result of odour and/or dust from the existing
industrial/commercial activity on adjacent land and nearby sites.
This buffer assessment will support a planning application to the City of Whitehorse Council. The
development proposal includes a rezoning application from Special Use zoning to Residential 1 Zone,
and a concurrent development application for the site.
The purpose of an amenity buffer is to provide sufficient separation between sensitive land uses (such as
residences) and industries that have the potential to generate emissions of dust and/or odour so that on
the occasion of an upset or malfunction, the disamenity off-site is minimised.
This report has been prepared in consideration of the recommended buffer distances as specified by
EPA Victoria1 (EPA) for a range of industry categories. It should be read in conjunction with the
limitations detailed in Section 8.
1.1 Scope of Works
The assessment comprised the following scope of works:
A review of an earlier air quality assessment2 conducted by SLR global environmental solutions
(SLR)
A site visit to identify and observe the current existing industries within the surrounding area of the
proposed development;
Describe the operations at those nearby industries that attract default buffers that extend close or
onto the subject site and consider the level of management applied to minimise fugitive emissions;
Assess potential future industries that may establish and their requirement for buffers;
Characterise the meteorology at the site by means of wind and stability roses to enable the directions
of good and poor dispersion to be determined;
Assess the appropriate interpolated default buffers for the identified industries;
Use site-representative meteorological data to determine the directional changes to the default
buffers; and
Conclude as to the appropriate buffers and constraints impacting the proposed residential
development at 15 Hay Street, Box Hill South.
1 EPA 1990 Recommended Buffer Distances for Industrial Residual Air Emissions, AQ2/86, Rev. July 1990 2 SLR “ Preliminary Environmental Assessment – Air Quality, 15 hay St development, Box Hill”,Version 1, 23 April 2012.
2
31/28957/210231 15 Hay Street Development, Box Hill Buffer Assessment
2. Project Description and Understanding
2.1 Project Description
2.1.1 Surrounding Land Uses / Environment
The proposed residential development is located at 15 Hay Street, Box Hill South, 15 km east of
Melbourne. An aerial photograph of the site is provided in Figure 2-1.
The land in question is abutted to the west by Residential (R1) zoned land on the west side of Hay St
and to the east and south east by Industrial zoned land between Gardiners Creek and Middleborough
Road. This land is termed the Box Hill South Industrial Precinct. There are several industries established
in this precinct that attract buffer distances.
North of the site land is zoned Public Park and Recreation Zone while to the south of the site the land is
zoned Special Use Zone 2 (currently occupied by the Box Hill golf club).
The proposed development (see Figure 2-2) comprises residential townhouses and apartments along the
western side of the site on high ground on the west flank of the Gardiners creek valley, and comprises
low rise retirement housing along the eastern side, on lower land adjacent to the creek. Currently there
are two building complexes on the site: the Hays International College and the Friendship Table Tennis
Association building at the south west corner of the site. The site is currently zoned Special Use Zone 1
(Hays International College).
At present the concept plan allows a ~60 m wide strip on the eastern margin – currently a vegetated area
along Gardiners Creek (i.e. park and recreation).
Canaan Holdings require an independent assessment of the appropriate buffers from the existing and
potential future industries in the IN1 zone, so that a judgement can be made as to whether the proposed
development concept is constrained by amenity buffers.
For the purpose of this assessment it has been assumed, consistent with the INZ1 zoning, that no future
offensive odour-generating industry would be approved within these zones, and that therefore there will
be no potential for future impact from these land zonings onto the proposed development. A planning
scheme map of the proposed site and the surrounding area showing the pattern of zoning is provided in
Figure 2-3. From this figure GHD notes that land along the eastern and southern boundaries of the site
are prone to inundation from Gardiners Creek. This may pose some constraints on the land independent
of any constraint posed by buffers from surrounding industries.
2.1.2 Nearest Existing Sensitive Land Uses
Sensitive land uses include residential areas, hospitals, schools and other similar uses where people are
present for an extended time period except in the course of their employment or leisure. The nearest
current residentially zoned land is located immediately to the west of Hay Street Box Hill South.
2.1.3 Whitehorse Industrial Strategy (2011)
This strategy provides a framework for employment and business in eight key industrial areas including
the Box Hill South precinct. As such, it gives an indication of Council’s intentions for the future
development of this precinct. Relevant extracts are given below.
3
31/28957/210231 15 Hay Street Development, Box Hill Buffer Assessment
Strategies to facilitate on-going development include:
Direct industrial uses into appropriate locations;
Discourage non-industrial related uses from locating in industrial areas;
Ensure industrial uses within these areas are suitable to protect the amenity of abutting land uses,
particularly if residential;
Provide a buffer between intense industrial activity and residential areas;
Require equitable development contributions to new residential, industrial and commercial uses; and
Developing appropriate zoning, overlay and design guidelines for strategic redevelopment sites,
responding to issues such as appropriate treatments to existing residential areas.
Specifically regarding the Middleborough/Clarice Road area:
The precinct has potential for integrated mixed use developments on large sites consisting of office
suits, office warehouse units and office/factory units of varying sized;
Large sites in this precinct have significant development potential as modern office/industrial parks
with quality building design, internal road networks, landscaping and on-site parking; and
There will be pressure for rezoning land fronting Middleborough Road for alternative uses such as
showrooms, trade supplies and bulky goods retailing as demonstrated by the approval of the office/
showroom development at 249 Middleborough Road. Any further erosion of the precinct in this
manner should be avoided as the precinct is capable of attracting high value added businesses that
can support a modern office/industrial form.
2.2 Surrounding Industries
A site inspection of the proposed development site and the surrounding area was conducted by GHD on
the 14th May 2012. Various existing premises with the potential for odour and dust emissions in an upset
scenario were identified.
As shown in Figure 2-4, there are several existing industrial premises in the immediate vicinity of the
subject site that would have the potential to generate off-site odour and/or dust impact in the event of a
process upset or malfunction. These premises would require a buffer to sensitive land uses to minimise
impact in such an event. In turn these buffers have the potential to constrain the proposed residential
development. The identified premises are listed below with their letter ID in figure 2-4 listed in brackets
and their distance in metres to the nearest portion of the Canaan property boundary (red contour) is also
given:
(A): SCA Hygiene Australia located along Alisa Street ~ 425 m south of the subject site;
(B): Cementaid located at 15 Clarice Road ~ 175 m southeast of the subject site;
(C): K&J Printing located at 3/11 Clarice Road ~220 m southeast of the subject site;
(D): Maton Guitar Factory located at 6 Clarice Road ~260 m southeast of the subject site;
(E): Wheelers Quality Cabinets located at 22-24 Clarice Road ~175 m southeast of the subject site ;
and
(F): Alexander’s Industrial Laundry located at 34 Clarice Road ~170 m east of the subject site.
4
31/28957/210231 15 Hay Street Development, Box Hill Buffer Assessment
Auto Repair Centres
(G) HCW Automotive located at 27 Clarice Road ~ 120 m southeast of subject site;
(H) Clarice Body Group located at 28 Clarice Road ~ 165 m southeast of the subject site;
(I) Woods Accident Repair Centre located at 30-32 Clarice Road ~ 170 m east of the subject site;
(J) Supaswift Performance Automotive Repairs located at 44 Clarice Road ~230 m east of the
subject site;
(K) Gown Hindhaugh and Auto Repair Centre located at 309-311 Middleborough Road ~ 240 m east
of the subject site, and
(L); Wiltshires Auto Services located at 290 Middleborough Road ~ 210 m east-northeast of the
subject site.
Mechanical Engineering of Metals
(M) Allan Industries located at 9 Clarice Road ~ 305 m south of the subject site; and
(N) Burdett Engineering located at 44 Clarice Road ~ 190 m east of the subject site.
A number of other industries were identified surrounding the proposed site development but are not
anticipated to generate any significant off-site air quality impacts - these include:
Electrical goods retailer;
Genesis Health Club;
Numerous Offices;
Indoor sports complex; and
Bunnings Warehouse.
Former Rhodia Chemicals Site
The former Rhodia site at 313 Middleborough Road has been sold to Momentive Specialty
Chemicals.The process equipment associated with Rhodia’s operations has been demolished, and the
site is currently undergoing an environmental audit (principally in relation to contamination of soil on-site)
with the potential for off-site air quality impacts during this time considered to be minimal and short term.
Any future plans to establish a chemical industry or any other facility will require Momentive Specialty
Chemicals to obtain a permit to operate from Council and a works approval from EPA.
2.2.1 Potential for Future Development
Numerous vacant premises were observed during the GHD site visit, and consistent with the Whitehorse
Industrial Strategy (2011) a number of warehouses have been approved along Clarice Road.
The potential for future industries with the potential to pose air quality constraints on the proposed
residential development is remote, in part because of the residential zoned land to the east and west will
constrain the establishment of any new industry requiring a significant buffer. Industrial 1 Zoning is
normally reserved only for small industrial facilities and warehouse type businesses, and for uses such
as retail, trade supplies and offices. These zones are sometimes sited in order to provide a buffer
between IN2 zoned land (designed to accommodate facilities requiring larger buffers) and residential
areas. In this case however, the IN1 zone is isolated. Also, given that this strip of IN1 land is narrow and
5
31/28957/210231 15 Hay Street Development, Box Hill Buffer Assessment
the blocks of land remaining are small, generally only small warehouse type industries are likely to
develop in the future.
2.3 Complaint History
GHD is unaware of any odour or dust complaints made to EPA or Council in relation to any of the
surrounding industries. Note that only the former Rhodia operation had a significant history of odour
complaints, but that operation has ceased.
Canaan Holdings Pty Ltd15 Hay Street Development, Box Hill -Buffer Assessment
Site Aerial Figure 2-1G:\31\28957\GIS\Maps\Working
2012. While GHD has taken care to ensure the accuracy of this product, GHD and DATA CUSTODIAN(S), make no representations or warranties about its accuracy, completeness or suitabilityfor any particular purpose. GHD and DATA CUSTODIAN(S) cannot accept liability of any kind (whether in contract, tort or otherwise) for any expenses, losses, damages and/or costs (includingindirect or consequential damage) which are or may be incurred as a result of the product being inaccurate, incomplete or unsuitable in any way and for any reason.
C8/180 Lonsdale St Melbourne VIC 3000 Australia 61 3 8687 8000 61 3 8687 8111 www.ghd.com.auT F W
Map Projection: Universal Transverse MercatorHorizontal Datum: Geocentric Datum of Australia 1994
Grid: Map Grid of Australia, Zone 55
Job NumberRevision
Date
31/28957A15/05/12
metres
1:5,000
o(at A4)
Data source: Google Earth Imagery 2012. Created by: MA
LEGEND
0 50 100 150
Site Boundary
Canterbury Rd
Mid
dleb
orou
gh R
d
Mid
dleb
orou
gh R
d
Stat
ion
St
Hay
St
Jellicoe St
Halsey St
Bea
ver S
t
Clar
ice
Rd
Bed f
ord
St
Kitc
hene
r St
Pake
nham
St
Abe
rdee
n R
d
Bir d
woo
d St
GA
RD
INE
RS
CR
EE
K
D R A I N
Mid
d leb
orou
gh R
d
Canterbury Rd
PAO4
PAO4
EAO
LSIO
SBO
HO52
HO8
SUZ2
PPRZ
SBO
R1Z
R1Z
R1Z
R1Z
IN1Z
PPRZ
SUZ2
RDZ1
SUZ1
PPRZ
PPRZ
PUZ1
PUZ2
SUZ1 PUZ2
PUZ1
B1Z
PPRZ
B1Z
B1Z
B2Z
PUZ6
B1Z
B1Z
PPRZ
PUZ1
UFZ
PPRZ
PPRZ
PPRZ
PPRZ
PUZ6MUZ
PPRZ
PPRZ
PPRZ
335,000
335,000
336,000
336,000
5,811
,000
5,811
,000
DRAFT
180 Lonsdale Street Melbourne VIC 3000 Australia T 61 3 8687 8000 F 61 3 8687 8111 E [email protected] W www.ghd.comG:\31\28957\GIS\Maps\Working\Planning Scheme Map.mxd
© 2012. Whilst every care has been taken to prepare this map, GHD (and DATA CUSTODIAN) make no representations or warranties about its accuracy, reliability, completeness or suitability for any particular purpose and cannot accept liability and responsibility of any kind (whether in contract, tort or otherwise) for any expenses, losses, damages and/or costs (including indirect or consequential damage) which are or may be incurred by any party as a result of the map being inaccurate, incomplete or unsuitable in any way and for any reason.
LEGEND
0 50 100 150 200 25025
MetresMap Projection: Transverse Mercator
Horizontal Datum: GDA 1994Grid: GDA 1994 MGA Zone 55
Canaan Holdings Pty Ltd15 Hay Street, Box HillBuffer Assessment
Figure 2-3
Job NumberRevision A
31-28957
16 May 2012
Planning Scheme Mapo Date
Data Source: VicMap 2012
Scale 1:5,000 @ A3
Site Boundary
Zones
Business 1
Business 2
Industrial 1
Mixed Use
Public Park and Recreation
Public Use 1 - Service & Utility
Residential 1
Road – Category 1
Urban Flood
Special Use 1- Private Education Centres
Overlays
Environmental Audit
Public Acquisition 4
Land Subject to Inundation
Special Building
Heritage
and Places of Worship
HO8 - Pound HouseHO52 - 47-49 Kitchener St. Box Hill
DDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDD
FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF
EEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEE
CCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCC
BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB
MMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
Non-OperationalNon-OperationalNon-OperationalNon-OperationalNon-OperationalNon-OperationalNon-OperationalNon-OperationalNon-OperationalNon-OperationalNon-OperationalNon-OperationalNon-OperationalNon-OperationalNon-OperationalNon-OperationalNon-OperationalNon-OperationalNon-OperationalNon-OperationalNon-OperationalNon-OperationalNon-OperationalNon-OperationalNon-OperationalNon-OperationalNon-OperationalNon-OperationalNon-OperationalNon-OperationalNon-OperationalNon-OperationalNon-OperationalNon-OperationalNon-OperationalNon-OperationalNon-OperationalNon-OperationalNon-OperationalNon-OperationalNon-OperationalNon-OperationalNon-OperationalNon-OperationalNon-OperationalNon-OperationalNon-OperationalNon-OperationalNon-OperationalSiteSiteSiteSiteSiteSiteSiteSiteSiteSiteSiteSiteSiteSiteSiteSiteSiteSiteSiteSiteSiteSiteSiteSiteSiteSiteSiteSiteSiteSiteSiteSiteSiteSiteSiteSiteSiteSiteSiteSiteSiteSiteSiteSiteSiteSiteSiteSiteSite
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN KKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHH
IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGG
LLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLL
Canaan Holdings Pty Ltd15 Hay Street Development, Box Hill -Buffer Assessment
Surrounding Industries Figure 2-4G:\31\28957\GIS\Maps\Working
2012. While GHD has taken care to ensure the accuracy of this product, GHD and DATA CUSTODIAN(S), make no representations or warranties about its accuracy, completeness or suitabilityfor any particular purpose. GHD and DATA CUSTODIAN(S) cannot accept liability of any kind (whether in contract, tort or otherwise) for any expenses, losses, damages and/or costs (includingindirect or consequential damage) which are or may be incurred as a result of the product being inaccurate, incomplete or unsuitable in any way and for any reason.
C8/180 Lonsdale St Melbourne VIC 3000 Australia 61 3 8687 8000 61 3 8687 8111 www.ghd.com.auT F W
Map Projection: Universal Transverse MercatorHorizontal Datum: Geocentric Datum of Australia 1994
Grid: Map Grid of Australia, Zone 55
Job NumberRevision
Date
31/28957A15/05/12
metres
1:5,000
o(at A4)
Data source: Google Earth Imagery 2012. Created by: MA
LEGEND
0 50 100 150
Site Boundary
10
31/28957/210231 15 Hay Street Development, Box Hill Buffer Assessment
3. Surrounding Industry Operations
A brief company overview and general manufacturing process is given below for those surrounding
industries with the potential to constrain the residential development at 15 Hay Street Box Hill South. The
following descriptions are based on the SLR Report Air Quality Report prepared for Canaan Holdings2,
GHD’s understanding of the processes of each industry, an examination of the facilities website where
available and a roadside site inspection. GHD did not make direct contact with the management of the
following facilities.
3.1 SCA Hygiene Australia
Tissue Product Manufacturer
SCA Hygiene manufactures tissue paper from semi-processed materials (i.e. pulp received in bales from
a pulp mill which process the logs/ wood chips into pulp by chemical and/ or mechanical means).
Emissions are generated in the paper product manufacturing industry at the manufacturing and
bleaching stage and in energy generation. Kraft chemical pulping and traditional chlorine-based
bleaching are both commonly used, and may generate significant emissions. The power on site is
generated by natural gas combustion.
Common air emissions from paper product manufacturing that can cause disamenity include particulates
and odour.
3.2 Cementaid
Cementaid is a manufacturer of mixtures and surface treatments for concrete. The potential emission to
air during concrete surface treatments such as admixtures, curing and bonding agents, waterproofing
treatments and sealants, grouting and glazing liquids that could cause disamenity is likely to be odour.
3.3 K&J Printing
K&J Printing is a commercial printing company where some amount of heat curing may take place.
Emissions to air such as PM10 and VOCs could occur during the general printing process, the use of
solvent based inks and cleaning solutions to remove excess ink would most likely be controlled and
vented. In the event of a process upset, the off-site impact is likely to be odour.
3.4 Alexander’s Industrial Laundry
Alexander’s Industrial Laundry is a commercial laundry. Although the exact machinery used on site is
unknown, in most modern dry cleaners the machines used for dry cleaning operate in a close looped
process to minimise emissions to air. The process does not vent gas to the atmosphere and recycles the
solvent throughout the cycle. Assuming a closed system the only point of emissions would be machine
loading and unloading. VOC emissions from dry cleaning solvents and lint from the driers are likely to the
emissions of potential concern. From the site inspection all plant equipment and machinery appear to be
located indoors with a potential for odour and lint emissions vented from the building headspace, to have
off-site impact.
11
31/28957/210231 15 Hay Street Development, Box Hill Buffer Assessment
3.5 Allan Industries
Allan Industries fabricate products in mild steel, stainless steel and aluminium. The workshop would
generally consist of precision machinery such as sheet metal cutting and folding equipment, as well as
metal punching, plasma cutting and spray painting facilities.
Metal Fabricators manufacture a large range of items such as:
Electrical cabinets;
Tanks and vessels;
Fume extraction and ventilation duct work;
Architectural features and handrails;
Pipe work;
Guarding;
Staircases and platforms;
Handrails and balustrades; and
Customised tradesman vehicle canopies and tool boxes.
Emissions generated during steel fabrication process are likely to include metal dust, odour from paint
solvents, and metal fumes from welding. The potential for nuisance dust and odours are normally
controlled by wet scrubbers and fabric filters.
3.6 Burdett Engineering
The SLR report indicates that no fabrication occurs at Burdett Engineering but only balancing services
(i.e. for rotor balancing). Emissions generated during this process are likely to include metal dust and
emissions of VOCs.
3.7 Maton Guitar Factory
Maton Guitar factory specialise in wooden guitar manufacturing which involves wood cutting, carving and
general handling. Potential emissions to air include dust and PM10 and VOCs during painting/lacquering.
The SLR report indicates that spray painting is undertaken inside an enclosed booth, and paint aerosol
emissions would be controlled by a curtain fabric filter. A cyclone is installed on the roof to trap
particulate matter from wood working operations.
3.8 Wheelers Quality Cabinets
Wheelers Quality Cabinets specialise in cabinet manufacturing which involves wood cutting, carving and
general handling. Potential emissions to air include dust and PM10 and VOCs during painting/lacquering.
12
31/28957/210231 15 Hay Street Development, Box Hill Buffer Assessment
3.9 Auto Repair Centres3
Potential emissions to air would be VOCs from solvent uses, fuel emissions from standing cars such as
diesel and petrol emissions of (VOCs, CO, NOx and SO2) and dust emissions from metal dust generated
from maintenance activities and repairs. Spray painting of vehicles is likely to occur on site, but most of
the repair centres have spray booths with vents and stacks leading to the roof which would treat
emissions via a filter or wet scrubber.
3 (HCW Automotive, Clarice Body Group, Woods Accident Repair Centre, Supaswift Performance Automotive Repairs, Wiltshires
Auto Services and Gown Hindhaugh and Auto Repair Centre)
13
31/28957/210231 15 Hay Street Development, Box Hill Buffer Assessment
4. Relevant Buffer Guidelines
Two classes of buffer /separation distance guidelines are relevant in the context of planning in Victoria.
Where there is an industrial use proposed on a land parcel, then the provisions of Clause 52.104 in the
Particular Provisions of the planning scheme apply. In effect, if the industry is specified in the Table to
the Clause, then the corresponding threshold distance to the nearest Residential Zone, Business 5 Zone,
Capital City Zone or Docklands Zone (the latter three not relevant here) must be met, otherwise a
planning permit must be sought.
In the case of an existing industrial use, for the EPAV1 recommend buffer distances to have effect, it
should be established in the planning scheme by means of an overlay. A buffer distance is a planning
instrument used to provide separation of sensitive land uses (i.e. residential, schools, hospitals) from
existing premises with the potential for off-site emissions (odour or dust) that can cause disamenity in the
event of an upset/malfunction. Under routine operations, odour/dust impact is to be confined on-site so
that an external buffer should not be required. Note that the buffer distance is scribed from the envelope
of emitting sources within the premises not from the perimeter boundary.
In this case, the EPAV recommended buffer distance guidelines apply to existing industries in the vicinity
of the proposed development with respect to the future planning of sensitive land uses.
4.1 EPA Buffer Guidelines
EPA publish1 recommended buffer distances for selected industry categories (EPA Guidelines). Buffer
distances can define zones of land off-site from the industry premises which are constrained from
development for sensitive land uses. Sensitive land uses include residential, hospitals, schools, caravan
parks and other similar uses.
Note that the Buffer Guidelines were reviewed in a position paper in 20025 as part of an EPA review to
develop the successor document to the guidelines, namely the Separation Distance PEM (Protocol for
Environmental Management). A methodology to pro-rate the default buffer for a given premises based on
throughput6 has also been used below for those industry categories where the range of industry size is
large.
4.2 Default and Recommended Buffers from Surrounding Industries
Existing industries located to the east of the development land extend buffers that may compromise
sections of the land. The particular premises potentially attracting buffers are shown in Figure 4-1 and
Table 4-1 are listed below. Each buffer distance is taken from the envelope of potential odour sources as
required by the EPA Guidelines. GHD has also recommended the buffer distances it considers
appropriate for those industries not specifically defined in the EPA guidelines.
Of the 14 existing industrial premises that were identified in the site visit as attracting a buffer, none had
the potential to cause constraint to the potential residential land development site at 15 Hay Street Box
4 Victorian Planning Provisions, Clause 52.10 “Uses with Adverse Amenity Potential” 5 Egis 2002 “Review of recommended Separation Distances for Industrial residual Emissions” report to EPA 30 Sept. 2002 6 Clarey P, Pollock T “Integrating Separation Distances with Dispersion Modelling” Enviro 04, 28 March – 1 April 2004, Darling
Harbour, Sydney.
14
31/28957/210231 15 Hay Street Development, Box Hill Buffer Assessment
Hill South. The identified industries either attract a default buffer that does not extend to the
development, or do not attract a buffer in the EPA guideline. Each industry is considered below.
SCA Hygiene Australia
The EPA guidelines recommend a separation distance of 100 m for ‘Paper or paper pulp from semi-
processed materials‘. It is noted that SCA Hygiene Australia operates under an EPA licence and is
required to meet certain licence conditions in relation to emissions to air.
Cementaid
Cementaid is a small cement treatment product manufacturer. The EPA does not specify a buffer
distance for cement surface treatment. A maximum buffer of 100 m is recommended by GHD to be used
for this premises.
K&J Printing
K&J Printing is a small printing company. The only relevant category in the EPA guidelines is Paint and
inks – blending and mixing only’, requiring a buffer of 300 m. However these distances are likely to refer
to large scale printing and painting processing. Note that this buffer can be reduced further on the basis
of obtaining site operational information as the upset/malfunction potential for printing are low to
negligible. GHD recommends a more realistic buffer of 100 m or less for such a small printing site.
Alexander’s Industrial Laundry
The relevant category in the EPA guidelines is ‘Industrial dry cleaners’ which requires a buffer distance of
100 m.
Allan Industries - Metal Fabrications
Allan Industries is a small to medium metal fabricator. The most relevant category in the EPA guidelines
is “Structural or sheet metal products” under ‘fabricated metal products’ which requires a buffer distance
of 500 m. This 500 m buffer is for a large sheet metal manufacturer with a total production rate of up to
1,000,000 tonnes per annum (tpa). It is more than likely that Allan Industries is well under this production
rate which would allow for a reduction in the buffer size based on annual throughput. Communication7
with the general manager, Jim Allan established that their annual throughput was less than 50,000 tpa
and the pro-rating6 methodology then gives an interpolated buffer distance Db as calculated below:
50,000
1,000,000
.
x500 100m
Burdett Engineering
Burdett Engineering is a small balancing service provider. The EPA guidelines do not specify a
separation distance for this industry type.
Maton Guitar factory
Maton Guitar factory specialise in wooden guitar manufacturing. The most relevant category in the EPA
guidelines is “Joineries” which requires a buffer distance of 100 m.
7 Pers. Comm. T.Pollock to J. Allan on 1 June 2012
15
31/28957/210231 15 Hay Street Development, Box Hill Buffer Assessment
Wheelers Quality Cabinets
Wheelers Quality Cabinets specialise in cabinet manufacturing. The most relevant category in the EPA
guidelines is “Joineries” which requires a buffer distance of 100 m.
Auto Repair Centres
The EPA guidelines do not specify a separation distance for this industry type. However the Egis review
recommended a buffer of 100 m for panel beating, and this would be appropriate for these premises. As
all of the identified auto repair centres are located greater than 100 m from the proposed residential
development there will be no constraint posed by these auto centres on the land at 15 Hay Street Box
Hill South.
Applying the GHD recommend buffers from Table 4-1 in Figure 4-1 it can be seen that none of the
identified industries extend a buffer to encroach on the proposed residential site. The closest buffer is
from Alexander’s Industrial Laundry located to the east.
Table 4-1 Default and Recommended Buffers for Existing Surrounding Industries
Industry Class Company EPA Default Buffer (m)
GHD Recommended Buffer Distance (m)
Paper from Semi-
processed materials SCA Hygiene 100 100
Laundry Alexanders Industrial
laundry 100 100
Joinery
Maton Guitar
100
100
Wheelers Quality
cabinets 100
Metal Fabricator Allans Industries
< 500 1003
Burdett Engineering nil
Paints and Inks K & J Printing
< 300 1003
Cementaid 100
Auto repair Various2 - 1001
1. Recommended addition under ‘Panel beaters’ – Egis 2002
2. Five of (HCW Automotive, Clarice Body Group, Woods Accident Repair Centre, Supaswift Performance
Automotive Repairs, Wiltshires Auto Services and Gown Hindhaugh and Auto Repair Centre)
3. Pro-rated on throughput
DDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDD
FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF
EEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEE
CCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCC
BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB
MMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
Canaan Holdings Pty Ltd15 Hay Street Development, Box Hill -Buffer Assessment
Default Buffers Figure 4-1G:\31\28957\GIS\Maps\Working
2012. While GHD has taken care to ensure the accuracy of this product, GHD and DATA CUSTODIAN(S), make no representations or warranties about its accuracy, completeness or suitabilityfor any particular purpose. GHD and DATA CUSTODIAN(S) cannot accept liability of any kind (whether in contract, tort or otherwise) for any expenses, losses, damages and/or costs (includingindirect or consequential damage) which are or may be incurred as a result of the product being inaccurate, incomplete or unsuitable in any way and for any reason.
C8/180 Lonsdale St Melbourne VIC 3000 Australia 61 3 8687 8000 61 3 8687 8111 www.ghd.com.auT F W
Map Projection: Universal Transverse MercatorHorizontal Datum: Geocentric Datum of Australia 1994
Grid: Map Grid of Australia, Zone 55
Job NumberRevision
Date
31/28957B05/06/12
metres
1:5,000
o(at A4)
Data source: Google Earth Imagery 2012. Created by: MA
LEGEND
0 50 100 150
Site Boundary
Envelope of PotentialSources
Default Buffers
17
31/28957/210231 15 Hay Street Development, Box Hill Buffer Assessment
4.3 Application of a Buffer to 15 Hay Street
4.3.1 Available Buffer for the Site
In general a buffer is scribed from the envelope of potential odour or dust sources and this is indicated in
Figure 4-1. The proposed development is abutted to the east by Industrial (IN1) zoned land on which
numerous existing industries operate that attract a buffer distance. The current available separation for
the proposed residential land comprises the vegetation strip along Gardiners Creek on the eastern site
boundary (~60 m). Hence there is adequate provision to separate the proposed residential component
from all existing industries, assuming the buffers recommended by GHD apply. There are no other
constraints on the proposed residential land from the north, west or south.
As explained in section 2.2.1 the potential for future industries with the potential to pose air quality
constraints on the proposed residential development is remote, in part because of the residential zoned
land to the east and west will constrain any industry requiring a significant buffer. Also Industrial 1 Zoning
is normally reserved only for small industrial facilities and warehouse type businesses for uses such as
retail, trade supplies and offices (buffers < 300 m) in order to provide a buffer between larger IN2
facilities to residential areas.
In assessing the internal buffer needed for the proposed residential development to provide amenity
protection from the existing surrounding industries, the previous performance of all the industries is
relevant. Excepting the former Rhodia operation, GHD is unaware of any recorded odour or dust
complaints to EPA or to Council for all of the surrounding industries within the Middleborough/Clarice
Road area.
18
31/28957/210231 15 Hay Street Development, Box Hill Buffer Assessment
5. Meteorology
5.1 Wind Pattern
Local wind climate largely determines the pattern of off-site odour and dust impact. The characterisation
of local wind patterns requires accurate site-representative hourly recordings of wind direction and speed
over a period of at least a year.
In 1995, EPAV installed an AQMS (Air Quality Monitoring Station) located at Box Hill, located on the west
flank of Gardiners Creek Valley just 2 km north of the proposed development site at 15 Hay Street Box
Hill South. The anemometer wind speed sensor was a wind vane and rotating cup type, but was replaced
with an acoustic anemometer in 2000. The earlier analysis conducted by Egis8 provided wind rose data
for the site based on a 12 month dataset for 1995. However, the acoustic sensor is more accurate at low
wind speeds, so a post 2000 dataset was sought. A 12-month dataset from the Box Hill EPAV AWS for
the twelve month period January 2008 – December 2008 has been validated and processed by EPA.
and this dataset was used in this exercise.
The effect of wind on dispersion patterns can be examined using the general wind climate and
atmospheric stability class distributions. The general wind climate at a site is most readily displayed by
means of wind rose plots, giving the incidence of winds from different directions for various wind speed
ranges.
The features of particular interest in this assessment are: (i) the prevailing wind directions and (ii) the
relative incidence of more stable light wind conditions.
Annual Pattern in Wind
The average wind rose for the entire data period is shown in Figure 5-1 and shows the following features:
The predominant annual average wind directions are from the north and north-northeast comprising
of 25% of incident winds, and south-southwest comprising of 20% of incident winds;
The most frequent winds are on a north-south axis, reflecting the Gardiners Creek Valley axis,
which aligns to north-northeast/south-southwest;
When winds are light and atmospheric conditions are stable, the near-surface air flows are guided
by the valley sides;
The incidence of westerly component winds (~4%) is substantially higher than easterlies occurring
<1 % of the time;
The annual average wind speed measured was 2.3 m/s, and
The observed wind speed distribution indicates that the largest proportion of high wind speeds (> 6
m/s) are from the north, while the largest proportion of light winds (<2 m/s) are from the NNE
8 Egis 2002 “proposed Buffer Distance to Apply between Rhodia Site and Former St Leo’s College” report to Becton and Rhodia
PPMC, Vp8683, March 2002.
31/2895
Figur
Seas
The s
D
d
n
D
th
to
is
S
a
T
57/210231
re 5-1 Ann
sonal variati
seasonal win
During winter
rainage flow
orth. They co
During summ
he late aftern
o the south o
s now southe
Spring and au
re observed
The seasonal
15 Hay Street DBuffer Assessme
ual Wind Ro
on in Wind
nd roses in F
, northerly w
ws towards Po
omprise 48%
er the influen
noon and eve
of this locatio
erly, and, inc
utumn are tra
as well as a
l incidence o
evelopment, Boxent
ose for Box
Pattern
igure 5-2 be
winds are the
ort Phillip Ba
% of incident
nce of the se
ening from th
n during the
luding SSW
ansitional pe
n increase in
f high winds
x Hill
Hill 2008
low show tha
most domin
ay from the h
winds (inclu
ea breeze is
he coast com
warmest mo
and SSE win
riods. Durin
n the frequen
(>6 m/s) is g
at:
ant due to pr
ills and mou
ding NNW a
evident as a
mbined with t
onths of the y
nds, compris
g these mon
ncy of synop
greatest in w
re-frontal nor
ntains from t
nd NNE);
result of sea
he synoptic s
year. The pr
ses of 47% o
nths both sum
tic westerlies
winter, and low
rtherlies and
the surround
a breezes ex
sub-tropical
redominant w
of total summ
mmer and wi
s;
west in summ
cool air
ding land in th
xperienced in
ridge migrati
wind directio
mer winds;
nter patterns
mer;
19
he
n
ing
n
s
20
31/28957/210231 15 Hay Street Development, Box Hill Buffer Assessment
The incidence of light (<2 m/s) winds is greatest in autumn, followed by winter and least in summer;
As with the annual wind rose, there is a lack of easterly winds in all seasons although winds south of
east can occur in summer, and
The direction and high proportion of light winds in autumn is a mixture between north and northeast.
These drainage flows are likely to be associated with high stability, and can be expected to define the
directions of poorest dispersion.
31/2895
Figur
Summ
Winte
57/210231
re 5-2 Seas
mer (average
er (average s
15 Hay Street DBuffer Assessme
sonal Wind
e speed = 2.
speed = 2.26
evelopment, Boxent
Roses for B
53 m/s)
6 m/s)
x Hill
Box Hill 20088
Autumn
Spring (
(average sp
average spe
peed = 1.92 m
eed = 2.60 m
m/s)
m/s)
21
22
31/28957/210231 15 Hay Street Development, Box Hill Buffer Assessment
5.2 Pattern of Atmospheric Stability
In the Pasquill/Gifford atmospheric stability scheme, stability is classified into six classes A through F.
A, B and C stability classes represent strongly, moderately and slightly unstable atmospheres
respectively. Under unstable conditions dispersion of emissions from near-ground sources is good
due to convectively vertical turbulent mixing. The stability category D denotes neutral atmospheric
conditions (strong winds in moderate temperatures or lighter winds on overcast to partly cloudy days).
Categories E and F denote slightly and moderately stable atmospheres when dispersion is poorest, as
vertical mixing of air is suppressed. Stable atmospheric conditions occur in the absence of strong
gradient winds, and mostly on nights with clear skies. They are often associated with ground-based
radiation forced temperature inversions, sometimes with fog, mist or frost.
Neutral stability (D class) conditions occur most frequently and along with the prevailing wind direction
can indicate the most common direction for potential impact. Under night-time E and F class conditions,
emissions from ground based sources; result in a downwind plume that is detectable to a greater
distance than during the day.
Annual Average Directional Pattern in Atmospheric Stability
Figure 5-3 shows the stability rose for the entire data period. Noting that a neutral atmosphere (D) is
normally the dominant stability state of the atmosphere, at Box Hill D class conditions occur at 33.6%
incidence while the A, B and C class contribute unstable atmospheres 34.3% of the time and the stable E
and F conditions occur at a 32.1% incidence. Figure 5-4 shows that the majority of stable winds are from
the north, northeast (~20%) and south-southwest (~9%). In other words, as expected, the down-valley
cool air drainage flow is the dominant stable flow direction. The occasional up-valley stable flow in lower
sections of Gardiners Creek was noted during dispersion investigations for the SE Freeway, and was
ascribed to the effect of the stronger Yarra valley drainage flow at the confluence of the valleys ‘pushing’
and temporarily reversing the drainage flow in Gardiners Creek.
31/2895
Figur
Seas
Figur
In
so
In
In
In
57/210231
re 5-3 Ann
sonal Variat
re 5-4 shows
n summer, th
outhwest- th
n winter, stab
n autumn, sta
n spring, stab
15 Hay Street DBuffer Assessme
ual Stability
tion in Atmo
s the following
he peak occu
is would refle
ble winds pre
able winds p
ble winds pre
evelopment, Boxent
y Rose for B
ospheric Sta
g seasonal v
urrence of sta
ect the incide
edominate fro
redominate f
edominate fro
x Hill
Box Hill 2008
ability
variation tren
able winds is
ence of the l
om the north
from the nor
om the north
8
nds in atmosp
s from the so
ate afternoo
h, north-north
th and northe
heast and so
pheric stabilit
outh, south-so
n sea breeze
hwest and no
east; and
uth-southwe
STACLA
ty:
outheast and
e;
orth-northeas
est.
ABILITY ASS
d south-
st;
23
31/2895
Figur
57/210231
re 5-4 Seas
15 Hay Street DBuffer Assessme
sonal Stabil
Summe
Winte
evelopment, Boxent
ity Roses fo
er
r
x Hill
or Box Hill 22008
Autumn
Spring
24
25
31/28957/210231 15 Hay Street Development, Box Hill Buffer Assessment
6. Directionally-Dependant Buffer
6.1 Directionally-Dependant Buffer for Existing Industries
Where site-representative meteorological data is available the directions of good and poor dispersion can
be identified as shown in Section 5. Further, if the 12 month dataset is configured to the approved
dispersion model Ausplume format (deriving atmospheric stability category and mixing height), then
dispersion modelling can be conducted using a nominal source emission rate (odour or dust) to
determine the directional change in extent from a default value of 100 m. The methodology to determine
the so-called directional buffer was developed by GHD and was presented at conference in 20046.
This was performed for the proposed facility using the 2008 Box Hill EPA meteorological dataset, and
adopting a nominal 10 m x 10 m area source with a nominal emission rate. The 99.5% contour that gave
the same enclosed area as a 100 m radius circle (i.e. 31,416 m2) was selected. The angular change in
buffer distance is given as a function of direction Θ in Table 6-1.
From Table 6-1 it is seen that the extent of the contour is significantly greater than 100 m in the down-
valley direction – out to 180 m. Similarly, the extent of the contour in the up-valley direction is slightly less
than 100 m, down to 90 m. In the cross-valley directions, the contraction is most marked to the west-
northwest, with a reduction to 46 m, while to the east, the reduction is less marked at 68 m.
The contour effectively gives the departure from the fixed 100 m radius that would be required if an equal
protection from disamenity was to be given in the event of an upset/malfunction.
The information in Table 6-1 has been used to form the directional buffer from the default 100 m buffer
for those industries cited in Table 4-1.
As seen in Figure 6-1 the 100 m directional buffers are contained within the radial default buffers in the
north, east and west directions, and with a large extension above the default 100 m (~80 m) to the
southwest (i.e. down-valley) away from the proposed development site.
Note that these directional buffer contours represent the smoothed maximum area required and may be
slightly larger in area than the default buffers.
26
31/28957/210231 15 Hay Street Development, Box Hill Buffer Assessment
Table 6-1 Directional Variation in Buffer using Local Meteorology – Box Hill 2008.
Direction
Sector deg.
Range
m
% of mean
range
Direction
Sector deg.
Range
m
% of mean
range
N 0 90 90 S 180 131 131
NNE 22.5 89 89 SSW 202.5 159 159
NE 45 91 91 SW 225 180 180
ENE 67.5 84 84 WSW 247.5 104 104
E 90 84 84 W 270 57 57
ESE 112.5 68 68 WNW 292.5 46 46
SE 135 68 68 NW 315 65 65
SSE 157.5 89 89 NNW 337.5 96 96
DDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDD
FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF
EEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEE
CCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCC
BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB
MMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
Canaan Holdings Pty Ltd15 Hay Street Development, Box Hill -Buffer Assessment
Directional Buffers Figure 6-1G:\31\28957\GIS\Maps\Working
2012. While GHD has taken care to ensure the accuracy of this product, GHD and DATA CUSTODIAN(S), make no representations or warranties about its accuracy, completeness or suitabilityfor any particular purpose. GHD and DATA CUSTODIAN(S) cannot accept liability of any kind (whether in contract, tort or otherwise) for any expenses, losses, damages and/or costs (includingindirect or consequential damage) which are or may be incurred as a result of the product being inaccurate, incomplete or unsuitable in any way and for any reason.
C8/180 Lonsdale St Melbourne VIC 3000 Australia 61 3 8687 8000 61 3 8687 8111 www.ghd.com.auT F W
Map Projection: Universal Transverse MercatorHorizontal Datum: Geocentric Datum of Australia 1994
Grid: Map Grid of Australia, Zone 55
Job NumberRevision
Date
31/28957B05/06/12
metres
1:5,000
o(at A4)
Data source: Google Earth Imagery 2012. Created by: MA
LEGEND
0 50 100 150
Site Boundary
Envelope of PotentialSources
Directional Buffers
28
31/28957/210231 15 Hay Street Development, Box Hill Buffer Assessment
6.2 Updated Appropriate Buffer for Proposed Development at 15 Hay Street
Taking the recommended directional buffers into account from Figure 6-1 it can be seen that they have
resulted in a reduced impact to the proposed residential site, compared to the default buffers
recommended in Table 4-1.
Thus the proposed development plan at 15 Hay Street (which allows for a thin strip of conservation land
along Gardeners Creek to the proposed residential housing) has a sufficient separation of greater than
70 m from the directional buffers posed by the existing industries to the east and south.
In Figure 6-1 it can be seen that this clearance is significantly greater than that of existing residences to
the south on Beaver St, and existing residences to the east on the east side of Middleborough Rd.
29
31/28957/210231 15 Hay Street Development, Box Hill Buffer Assessment
7. Conclusions
The following conclusions should be read in conjunction with the limitations detailed in Section 8.
The proposed residential development is not constrained for sensitive land use when appropriate
buffer distances are applied to the existing industries in the Industrial zoned area to the east and
south of the site;
For existing industries the appropriate buffers should be scribed from the envelope of potential
emitting sources. Allowance can be made for plausible future expansions when defining the
envelope;
Given the Whitehorse Industrial Strategy goals, it is unlikely that future industries requiring significant
(i.e. > 100 m) would be allowed to establish in the north end of the Box Hill South Industrial Precinct;
Local meteorology can be used to determine directional buffers so as to ensure the degree of
protection from disamenity in the event of a process upset is independent of the direction from the
industrial site;
The correction to take account of local meteorology is a small reduction towards the north and west
(in the directions of the proposed site), while there is a large increase beyond the default buffer to the
south-southwest, away from the development, and
The proposed development plan provides significant separation of greater than 70 m between the
residential components and the buffers posed by existing industries.
The separation of the proposed development plan to industry directional buffers is greater than that
available to existing residences in Beaver St and on Middleborough Rd.
30
31/28957/210231 15 Hay Street Development, Box Hill Buffer Assessment
8. Limitations
This Report has been prepared by GHD for Canaan Holdings Pty Ltd and may only be used and relied
on by Canaan Holdings Pty Ltd for the purpose agreed between GHD and Canaan Holdings Pty Ltd.
GHD otherwise disclaims responsibility to any person or entity other than Canaan Holdings Pty Ltd
arising in connection with this Report. GHD also excludes implied warranties and conditions, to the
extent legally permissible.
The services undertaken by GHD in connection with preparing this Report were limited to those
specifically detailed in the Report and are subject to the scope limitations set out in the Report.
The description of operations at all identified neighbouring industries has been based on their respective
websites where available, site inspection conducted by GHD and use of the descriptions given in the
SLR report conducted for Canaan Holdings Pty Ltd. GHD does not guarantee the accuracy of this
information.
The opinions, conclusions and any recommendations in this Report are based on conditions encountered
and information reviewed at the date of preparation of the Report. GHD has no responsibility or
obligation to update this Report to account for events or changes occurring subsequent to the date that
the Report was prepared.
The opinions, conclusions and any recommendations in this Report are based on assumptions made by
GHD described in this Report. GHD disclaims liability arising from any of the assumptions being
incorrect.
GHD has prepared this Report on the basis of information provided by Canaan Holdings Pty Ltd, which
GHD has not independently verified or checked beyond the agreed scope of work. GHD does not accept
liability in connection with such unverified information, including errors and omissions in the Report which
were caused by errors or omissions in that information.
31/28957/210231 15 Hay Street Development, Box Hill Buffer Assessment
GHD
180 Lonsdale Street
Melbourne, Victoria 3000
T: (03) 8687 8000 F: (03) 8687 8111 E: [email protected]
© GHD 2012
This document is and shall remain the property of GHD. The document may only be used for the purpose
for which it was commissioned and in accordance with the Terms of Engagement for the commission.
Unauthorised use of this document in any form whatsoever is prohibited.
Document Status
Rev No.
Author Reviewer Approved for Issue
Name Signature Name Signature Date
0 M.Asimakis
T. Pollock
T. Pollock
M. Koller
05/06/12