Remote control panel for the FSN/media/Downloads/Brochures/2011...The RCP-120 is fully integrated...

2
RCP-120 Remote control panel for the FSN The Remote Control Panel (RCP-120) enables you to control of the FSN multi-format switcher AUX outputs from a remote location. The RCP-120 allows you to remotely control routing sources to the FSN AUX outputs. This means you can select sources for monitoring, perform adjustments or record without interfering with the main production workflow managed by the FSN-150 control panel. The RCP-120 is fully integrated with the FSN system. Dedicated menus allow the setup and configuration of the RCP-120 from the FSN control panel. An integrated web interface is also provided for remote setup and configuration. The RCP-120 is available in a slim 1RU package featuring 12 high-resolution color LCD displays that allow for electronic labeling. The panel provides selection of up to 20 sources. Up to thirty-two (32) RCP-120 units can be connected to the FSN system via an Ethernet switch. The buttons on the RCP-120 follow the input bus mapping and source labeling as defined on the FSN control panel. The RCP-120 operates in two modes: standard and mixer. In standard mode, AUX outputs are switched immediately after you press the source button. In mixer mode, you can assign an additional panel to Preview and transitioned to Program by pressing the AUTO TRANS button. Features Remote control of FSN AUX outputs Integrated with the FSN menu system 12 high resolution graphic LCD displays Selection of up-to 20 sources (10 unshifted and 10 shifted) Integrated web interface Up-to 32 RCP-120 can be connected to the FSN system Ethernet Remote Control Standard and AUX Mixer mode Low Power consumption 1 RU

Transcript of Remote control panel for the FSN/media/Downloads/Brochures/2011...The RCP-120 is fully integrated...

Page 1: Remote control panel for the FSN/media/Downloads/Brochures/2011...The RCP-120 is fully integrated with the FSN system. Dedicated menus allow the setup and configuration of the RCP-120

RCP-120Remote control panel for the FSN

The Remote Control Panel (RCP-120) enables you to control of the FSN multi-format

switcher AUX outputs from a remote location.

The RCP-120 allows you to remotely control routing sources to the FSN AUX outputs. This

means you can select sources for monitoring, perform adjustments or record without

interfering with the main production workflow managed by the FSN-150 control panel.

The RCP-120 is fully integrated with the FSN system. Dedicated menus allow the

setup and configuration of the RCP-120 from the FSN control panel. An integrated web

interface is also provided for remote setup and configuration.

The RCP-120 is available in a slim 1RU package featuring 12 high-resolution color LCD

displays that allow for electronic labeling. The panel provides selection of up to 20

sources. Up to thirty-two (32) RCP-120 units can be connected to the FSN system via an

Ethernet switch. The buttons on the RCP-120 follow the input bus mapping and source

labeling as defined on the FSN control panel.

The RCP-120 operates in two modes: standard and mixer. In standard mode, AUX

outputs are switched immediately after you press the source button. In mixer mode,

you can assign an additional panel to Preview and transitioned to Program by pressing

the AUTO TRANS button.

Features

• Remote control of FSN AUX outputs

• Integrated with the FSN menu system

• 12 high resolution graphic LCD displays

• Selection of up-to 20 sources (10 unshifted and 10 shifted)

• Integrated web interface

• Up-to 32 RCP-120 can be connected to the FSN system

• Ethernet Remote Control

• Standard and AUX Mixer mode

• Low Power consumption

• 1 RU

Page 2: Remote control panel for the FSN/media/Downloads/Brochures/2011...The RCP-120 is fully integrated with the FSN system. Dedicated menus allow the setup and configuration of the RCP-120

www.barco.com

Pres. Kennedypark 35 8500 Kortrijk, Belgium

T: +32 56 36 80 47 - F: + 32 56 36 83 86E: [email protected]

Barco

M00438-R00-0411-DS April 2011

The information and data given are typical for the equipment described. However any individual item is subject to change without any notice. The latest version of this brochure can be found on www.barco.com.

Application diagram

11101 Trade Center DriveRancho Cordova, CA 95670, USA

T: +1 916 859 2500F: +1 916 859 2515

RCP-120

Power connector 2-pin Phoenix Connector

Power consumption 12 VDC, 1.1A

Communication LAN: 10/100 Mbps, RJ-45 single port

Serial: 8,N,1 @9600 baud

Dimensions (HxWxD) 1.75 x 19.00 x 1.76in / 4.4 x 48.26 x 4.47 cm (1RU)

Weight 0.5 lbs (0.23 kg)

Temperature 0 - 40 degrees C

Power supply

Input voltage 100 to 240VAC

Input frequency 50 to 60Hz

Current RMS (Max) 0.6A

Output voltage 12VDC

Current (max) 1.5A

Dimensions (HxWxD) 2.91x1.71x1.33in / 7.4x4.35x3.4 cm

Weight 0.5 lbs (0.23 kg)

Temperature 0 - 40 degrees C

Humidity 20 - 85% non-condensing

Certifications RCP-120 and power supply

EMI/EMC EN55022:2006, Class A, FCC Part 15 Subpart B Class B

Safety EN60065, EN60950

Order n° RCP-120 R9004670

Specifications