Relicell Tubular

2
Lasts longer Works harder Relicell Tubular Battery Relicell Long Life Tubular batteries are specially designed to withstand long and frequent power cuts with very low maintenance requirements. They are manufactured at a state of the art ISO 9001:2000 certified factory using the latest high pressure casting technology for better performance and durability, and conform to BIS 13369 – 1992. Relicell Tubular batteries have a long cyclic life span (more than 1000 cycles at 80% depth of discharge), high specific energy and low self discharge rate. They are ideally suited to use in applications that require deep cycling under extreme operating conditions. Hence the Relicell Tubular battery is the ideal companion for your Inverter or UPS during prolonged and frequent powercuts. All Relicell tubular batteries are supplied in factory charged condition thereby ensuring quality and optimum life. Relicell has an extensive service network across India to offer support for the products sold. Features Tubular positive plates made from highly corrosion resistant lead alloy Strong & rugged translucent PP Container with heat sealed cover with handles for easy lifting Micro porous aqua trap ceramic vent plug with electrolyte level indicator. Prevents acid mist coming out from cells Deep Cycle Design with low maintenance High porosity PE separators provides low electrical resistance and prevents oxidation Superior active material for excellent discharge performance 42 months warranty First 30 months – Free repair and replacement. 31st to 42nd month – Replacement at 40% discount on the prevailing MRP. Warranty is subject to the conditions mentioned in the Warranty Card. Inverters & UPS Solar & Wind energy storage Telecommunications power supply Emergency lighting Office Automation Equipment Applications

Transcript of Relicell Tubular

Page 1: Relicell Tubular

Lasts longer Works harder

Relicell Tubular Battery

Relicell Long Life Tubular batteries are specially designed to withstand long and frequent power

cuts with very low maintenance requirements. They are manufactured at a state of the art ISO

9001:2000 certified factory using the latest high pressure casting technology for better performance

and durability, and conform to BIS 13369 – 1992.

Relicell Tubular batteries have a long cyclic life span (more than 1000 cycles at 80% depth of

discharge), high specific energy and low self discharge rate. They are ideally suited

to use in applications that require deep cycling under extreme operating conditions.

Hence the Relicell Tubular battery is the ideal companion for your Inverter or UPS

during prolonged and frequent powercuts.

All Relicell tubular batteries are supplied in factory charged

condition thereby ensuring quality and optimum life.

Relicell has an extensive service network across India to offer

support for the products sold.

Features

� Tubular positive plates made from highly corrosion resistant lead alloy

� Strong & rugged translucent PP Container with heat sealed cover with handles for easy lifting

� Micro porous aqua trap ceramic vent plug with electrolyte level indicator. Prevents acid mist

coming out from cells

� Deep Cycle Design with low maintenance

� High porosity PE separators provides low electrical resistance and prevents oxidation

� Superior active material for excellent discharge performance

42 months warranty

First 30 months – Free repair and replacement.

31st to 42nd month – Replacement at 40%

discount on the prevailing MRP. Warranty is

subject to the conditions mentioned in the

Warranty Card.

Inverters & UPS

Solar & Wind energy storage

Telecommunications power supply

Emergency lighting

Office Automation Equipment

Applications

Page 2: Relicell Tubular

Initial charging and filling instructionsFill battery grade sulphuric acid in all the cells upto the

specified levels.

Acid specific gravity should be 1.250 0.005 at 27O C.

Charge to be initiated after at least 4 hours of initial soaking

period.

Charge the batteries with constant current as indicated in

the table until battery voltage reaches above 15.6 V and

for a minimum of 12 hours.

Full charged specific gravity should be adjusted to 1.250

0.005 at 27O C.

Ensure that the cell temperature never goes beyond 45O C

during charging. If it goes higher reduce the rate and

continue charging.

Greenvision Technologies Pvt. Ltd

45/1, 4th Cross, Malleswaram, Bangalore-560003, India.

Tel: +91-80-42459459, Fax: +91-80-42459460,

Email: [email protected]

Branches

� Bangalore � Chennai � Kolkata � Mumbai

� New Delhi � Secunderabad

Statutory warning

All batteries contain lead that is harmful to

your health and the environment. As per law

the used batteries should not be discarded,

but returned to the authorized dealer from

whom you purchase the replacement.

Relicell Service Centres in India

� Agra � Ahmedabad � Aurangabad � Bangalore � Baroda � Bhopal � Bhubaneshwar � Chandigarh � Chennai � Cochin � Coimbatore

� Dehradun � Delhi � Ghaziabad � Goa � Gurgaon � Guwahati � Hubli � Indore � Jabalpur � Jaipur � Jammu � Kolkata � Lucknow � Ludhiana

� Madurai � Mangalore � Mumbai � Nagpur � Nashik � Parwanoo� Patna � Pondicherry � Pune � Raipur � Rajkot � Ranchi � Secunderabad � Siliguri � Surat � Trivandrum � Varanasi � Vasai � Vijaywada � Vizag

www.relicellbattery.com

TUBULAR BATTERY

1R

EL

100T

12 V

100

8067

5751

4051

321

525

023

3913

.28

8032

0

2R

EL

120T

12 V

120

100

8372

6450

513

215

250

2844

12.7

1210

040

0

3R

EL

135T

12 V

135

115

9682

7156

515

275

270

3452

1513

115

460

4R

EL

150T

12 V

150

120

100

8676

6051

827

526

537

5514

.515

120

480

1R

EL

120X

LTT

12 V

125

100

8372

6450

452

180

390

3149

14.5

1010

040

0

2R

EL

150X

LTT

12 V

150

120

100

8676

6045

218

039

037

5514

1212

048

0

3R

EL

190X

LTT

12 V

190

150

125

108

9575

505

190

415

4465

20.8

1315

060

0

4R

EL

210X

LTT

12 V

220

180

150

129

114

9050

519

041

552

7118

1618

072

0

Tec

hn

ica

l S

pe

cif

ica

tio

ns

Sl.N

o.

Ba

tte

ry M

od

el

No

min

al

Vo

lta

ge

20 h

r10

hr

5 h

r3

hr

2 h

r1

hr

L *

W *

HD

ryW

et

Ap

pro

x lit

re

5%

Min

Ma

x

Ra

ted

Ca

pa

cit

yD

ime

nsi

on

s (m

m).

Ap

pro

x B

att

ery

Ac

id V

olu

me

Co

nst

an

t C

urr

en

tTr

ickl

e C

ha

rge

(AH

) a

t 27

O C

3

mm

Wei

ght (

Kgs

) 5

% C

harg

e R

ate

(Am

ps)

Ra

te (

Am

ps)

Re

lic

ell

Sta

nd

ard

Tu

bu

lar

Ba

tte

rie

s

Re

lic

ell

Ta

ll T

ub

ula

r B

att

eri

es