Electronic Products and RelaysSelection tables
-
Time relays, CT rangeThree ranges of electronic timers provide timing functions for all applications: the CT-D range with a width of just 17.5mm; the CT-E range, the ideal solution for serial applications; and the CT-S range that has two different types of connection terminals and is ideally suited for universal use. The CT range has a wide varity of timing functions (from ON or OFF delay to star-delta changeover). The time relays are available with output relays, solid-state outputs and precise direct time adjustment.
6
5
4
3
2
1
Electronic products and relaysThe product range
Measuring and monitoring relays, CM rangeState of the Art monitors for single and three-phase systems. Monitoring of: voltage, current, frequency, power factor (motor load), thermistors, temperature, liquid level, insulation resistance, and grid feeding. ABB has one of the worlds widest product ranges of measuring and monitoring relays. The CM range is a key product line of the EPR range.
Power supplies, CP rangeModern power supply units are a vital component in most areas of energy management and automation technology. As your global partner in this area, ABB pays close attention to corresponding requirements. Innovation is the key to the substantial enlargement of our power supply product range. ABB offers four different product lines for single and three-phase sup-plies, output voltages 5/12/24, and 48 VDC in plastic and metal enclosure, as well as various accessories.
Signal converters, CC range and ILPHThe ABB serial data converters allow communication to be established between units with different communication standards. In order to assure process continuity, existing systems must be updated consistently or connected to new devices. Serial data enables communication to be established if the communi-cation standard of the existing system and the connected device vary. As well as converting signals, analog signal converters and serial data converters can amplify, filter or separate signals.
Interface relays and optocouplers, CR range and R600Interface relays and optocouplers are widely used in various industrial applications. As an interface, they link the controller, e.g. PLC (programmable logic controller), PC or field bus systems to the sensor/actuator level. Here, they have various functions: switching AC or DC loads with different resistive, inductive and capacitive parts, switching voltages from a few mV up to 250 V, switching currents from a few mA up to 16 A, amplification of weak control signals, electrical isolation of control and load cir-cuits, and signal multiplying.
Logic relays, CL rangeCL range logic relays are suitable for small and medium-sized control tasks and can substitute logic wiring quickly and easily. Three different ranges are available: stand alone, expandable and the display systems.
2 ABB | EPR Selection Tables | 1SXP110002C0201 1SXP110002C0201 | EPR Selection Tables | ABB 3
-
11
4 ABB | EPR Selection Tables | 1SXP110002C0201 1SXP110002C0201 | EPR Selection Tables | ABB 5
:740
:740
:740
:740
:740
:740
:740
:740
:740
:740
:740
:740
:740
:740
:740
:740
:740
:740
:740
:730
:730
:730
:730
:730
:730
:730
:730
:730
:730
:730
:730
:730
:730
:730
:730
:730
:730
:730
Ord
er n
um
ber
1SV
R 5
00 0
20 R
0000
1SV
R 5
00 0
20 R
1100
1SV
R 5
00 1
00 R
0000
1SV
R 5
00 1
00 R
0100
1SV
R 5
00 1
10 R
0000
1SV
R 5
00 1
10 R
0100
1SV
R 5
00 1
30 R
0000
1SV
R 5
00 1
50 R
0000
1SV
R 5
00 1
60 R
0000
1SV
R 5
00 1
60 R
0100
1SV
R 5
00 2
11 R
0100
1SV
R 5
00 2
10 R
0100
1SV
R x
xx 0
20 R
0200
1SV
R x
xx 0
20 R
3300
1SV
R x
xx 0
21 R
2300
1SV
R x
xx 0
20 R
3100
1SV
R x
xx 0
30 R
3300
1SV
R x
xx 0
10 R
0200
1SV
R x
xx 0
10 R
3200
1SV
R x
xx 0
40 R
3300
1SV
R x
xx 1
00 R
0300
1SV
R x
xx 1
00 R
3300
1SV
R x
xx 1
00 R
3100
1SV
R x
xx 1
80 R
0300
1SV
R x
xx 1
80 R
3300
1SV
R x
xx 1
80 R
3100
1SV
R x
xx 1
10 R
3300
1SV
R x
xx 1
20 R
3100
1SV
R x
xx 1
20 R
3300
1SV
R 4
30 2
61 R
6000
1SV
R 4
30 2
61 R
5000
1SV
R x
xx 2
10 R
3300
1SV
R x
xx 2
11 R
2300
Typ
e
CT-
MFD
.12
CT-
MFD
.21
CT-
ER
D.1
2
CT-
ER
D.2
2
CT-
AH
D.1
2
CT-
AH
D.2
2
CT-
VW
D.1
2
CT-
EB
D.1
2
CT-
TGD
.12
CT-
TGD
.22
CT-
SD
D.2
2
CT-
SA
D.2
2
CT-
MV
S.2
1
CT-
MV
S.2
2
CT-
MV
S.2
3
CT-
MV
S.1
2
CT-
MX
S.2
2
CT-
MFS
.21
CT-
MB
S.2
2
CT-
WB
S.2
2
CT-
ER
S.2
1
CT-
ER
S.2
2
CT-
ER
S.1
2
CT-
AP
S.2
1
CT-
AP
S.2
2
CT-
AP
S.1
2
CT-
AH
S.2
2
CT-
AR
S.1
1
CT-
AR
S.2
1
CT-
VB
S.1
7
CT-
VB
S.1
8
CT-
SD
S.2
2
CT-
SD
S.2
3
Functions
ON-delay J J J J J J J J J J J J J JOFF-delay J J J J J J J J J J J J J J J J J JON- and OFF-delay J J J J J J JImpulse-ON J J J J J J J J J JImpulse-OFF J J J J J J J JImpulse-ON and OFF JFlasher starting with ON J J J J J JFlasher staring with OFF J J J J JFlasher starting with ON or OFF J J J JPulse generator starting with ON or OFF J J JPulse former J J J J J J J J J JStar-delta change-over J J J JStar-delta change-over with impulse J J J J JFurther functions
Control Input J J J J J J J J J J J J J J J J Jremote potentiometer J J J JTime range
0.05 s - 100 h J J J J J J J J J J0.05 s - 10 min J J J J J J0.05 s - 300 h J J J J 2 J J J J J J J J J JSupply voltage
24-48 V DC J J J J J J J J J J J J J J J J J J J J J J24-240 V AC J J J J J J J J J J J J J J J J J J J J J J12-240 V AC/DC J24-240 V AC/DC J J J J J J100-127 V AC J220-240 V AC J380-440 V AC J JOutput
c/o contact 1 2 1 2 1 2 1 1 1 2 2 2 2 1 2 2 2 2 2 2 1 2 2 1 2 1 2
n/o contact 2 2 2 2
Time RelaysCT-D & CT-S Range
0.6917,5
3.15
80
0.25
2.28
1.71
58
43,4
1.77
45
2CD
C 2
52 1
30 F
0b06
0.69
2.76
0.22.28
1.71
1.77
17,5
70
5
58
43,4
45
2CD
C 2
52 1
31 F
0b06
113.4 4.47
22.5 0.89
85.6
3.37
103.7 4.08
105.9 4.17
Dimensional drawings
dimensions in mm
1SVR500... with 1 c/o contact or 2 n/o contacts
1SVR500... with 2 c/o contacts 1SVR730... and 1SVR740...
Scr
ewP
ush
-in
MT-x50B
Marker label 29.6 x 44.5 mm
Marker label with scale 0-10 48.5 x 44.5 mm
Marker label with scale 0-50 48.5 x 44.5 mm
30 mm adapters
Remote potentiometer 50 kq 20 % - 0,2 q, degree of protection IP66
Material Diameter in mm
Type Order code Pack.- unit pieces
Weight 1 piece g / oz
Plastic, black 22.5 MT-150B MT-150B 1 0.040
Metal, chrome 22.5 MT-350B MT-350B 1 0.048
30 mm adapter for attaching the potentiometer 22 mm in 30 mm mounting hole
Marker label
Marker label
Accessories
Material Type Order code Pack.- unit pieces
Weight 1 piece g / oz
Plastic, black KA1-8029 KA1-8029 1
Metal, chrome KA1-8030 KA1-8030 1
Material for devices Type Order code Pack.- unit pieces
Weight 1 piece g / oz
Adapter for screw mounting CT-S
22.5 mm
ADP.01 1SVR430029R0100 1 18.4/0.65
Sealable transparent cover COV.01
1SVR430005R0100 1 5.2/0.18
Sealable transparent cover
CT-S.P/S 22.5 mm COV.11
1SVR730005R0100 1 4 / 0.129
Caption Type Order code Pack.- unitpieces
Weight 1 piece g / oz
Symbol (see illustration) SK 615 562-87 SK 615 562-87 1 0.002
Scale 0 - 10 CBK-NPEPOT CBK-NPEPOT 1 0.002
Scale 0 - 50 1SFA611930R1252 1 0.002
Material for devices Type Order code Pack.- unit pieces
Weight 1 piece g / oz
Marker CT-S without DIP switch MAR.011SVR366017R0100 10 0.19/0.007
Marker CT-S with DIP switch MAR.021SVR430043R0000 10 0.13/0.005
Marker CT-S.S/P with DIP switch MAR.121SVR730006R0000 10 0.152/0.335
Time RelaysCT-D & CT-S Range - Accessories & Dimensions
stock items
-
11
6 ABB | EPR Selection Tables | 1SXP110002C0201 1SXP110002C0201 | EPR Selection Tables | ABB 7
Ord
er n
um
ber
1SV
R55
0029
R81
00
1SV
R55
0107
R11
00
1SV
R55
0107
R41
00
1SV
R55
0107
R21
00
1SV
R55
0107
R51
00
1SV
R55
0100
R11
00
1SV
R55
0100
R41
00
1SV
R55
0100
R21
00
1SV
R55
0100
R51
00
1SV
R55
0118
R11
00
1SV
R55
0118
R41
00
1SV
R55
0118
R21
00
1SV
R55
0110
R11
00
1SV
R55
0110
R41
00
1SV
R55
0110
R21
00
1SV
R55
0111
R11
00
1SV
R55
0111
R41
00
1SV
R55
0111
R21
00
1SV
R55
0127
R11
00
1SV
R55
0127
R41
00
1SV
R55
0120
R11
00
1SV
R55
0120
R41
00
1SV
R55
0137
R11
00
1SV
R55
0137
R41
00
1SV
R55
0137
R21
00
1SV
R55
0130
R11
00
1SV
R55
0130
R41
00
1SV
R55
0130
R21
00
1SV
R55
0158
R31
00
1SV
R55
0150
R31
00
1SV
R55
0151
R31
00
1SV
R55
0148
R11
00
1SV
R55
0148
R41
00
1SV
R55
0148
R21
00
1SV
R55
0140
R11
00
1SV
R55
0140
R41
00
1SV
R55
0140
R21
00
1SV
R55
0141
R11
00
1SV
R55
0141
R41
00
1SV
R55
0141
R21
00
1SV
R55
0167
R11
00
1SV
R55
0160
R11
00
1SV
R55
0207
R11
00
1SV
R55
0207
R41
00
1SV
R55
0207
R21
00
1SV
R55
0200
R11
00
1SV
R55
0200
R41
00
1SV
R55
0200
R21
00
1SV
R55
0217
R41
00
1SV
R55
0210
R41
00
1SV
R55
0212
R41
00
1SV
R55
0019
R00
00
1SV
R55
0509
R10
00
1SV
R55
0509
R40
00
1SV
R55
0509
R20
00
1SV
R55
0519
R10
00
1SV
R55
0519
R40
00
1SV
R55
0519
R20
00
Typ
e
CT-
MFE
CT-
ER
E
CT-
AH
E
CT-
AR
E
CT-
VW
E
CT-
AW
E
CT-
AW
E
CT-
EB
E
CTY
DE
CT-
SD
E
CT-
MK
E
CT-
EK
E
CT-
AK
E
Functions
ON-delay J J J J J J J J J J J J JOFF-delay J J J J J J J J J J J J J J J J JImpulse-ON J J J J J J J JImpulse-OFF J J J J J J J J J J J JFlasher starting with ON J JFlasher staring with OFF J J J JPulse former JStar-delta change-over twice ON-delayed J J J J J J J J JFurther functions
Control Input J J J J J J J J J J J J J J J J J J Jwithout auxilliary voltage J J J J J J J J J J J J JTime range
0.05 s - 100 h J0.05 s - 1 s J J J0.1 s - 10 s J J J J J J J J J J J J J J J J J J J0.3 s - 30 s J J J J J J J J J J J J J J J J J J J3 s - 300 s J J J J J J J J J J J J J J J0.3 min - 300 min J JSupply voltage
24-240 V AC J J J24-240 V AC/DC J J J J J110-130 V AC J J J J J J J J J J J J J J J J J J J J J24 V AC/DC J J J J J J J J J J J J J J J J J J J J J220-240 V AC J J J J J J J J J J J J J J J J J J J J J380-415 V AC JOutput
c/o contact 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
n/o contact 1 1 1
n/c contact 1 1 1
Solid-state J J J J J J J
Time RelaysCT-E Range
3.48
3.19
3.09
.886
3.07
88,5
81
78,5
78
22,5
2CD
C 2
52 1
89 F
0b05
Dimensional drawings
dimensions in mm
1SVR550...
stock items
-
22
8 ABB | EPR Selection Tables | 1SXP110002C0201 1SXP110002C0201 | EPR Selection Tables | ABB 9
Measuring and Monitoring RelaysSingle-phase current monitoring relays
Measuring and Monitoring RelaysSingle-phase voltage monitoring relays
Dimensional drawings
dimensions in mm
113.4 4.47
22.5 0.89
85.6
3.37
103.7 4.08
105.9 4.17
Ord
er n
um
ber
1SV
R73
0840
R02
00
1SV
R74
0840
R02
00
1SV
R73
0841
R02
00
1SV
R74
0841
R02
00
1SV
R73
0841
R12
00
1SV
R74
0841
R12
00
1SV
R73
0840
R03
00
1SV
R73
0841
R03
00
1SV
R73
0841
R13
00
1SV
R73
0840
R04
00
1SV
R74
0840
R04
00
1SV
R73
0841
R04
00
1SV
R74
0841
R04
00
1SV
R73
0841
R14
00
1SV
R74
0841
R14
00
1SV
R73
0840
R05
00
1SV
R73
0841
R05
00
1SV
R73
0841
R15
00
1SV
R73
0840
R06
00
1SV
R74
0840
R06
00
1SV
R73
0840
R07
00
1SV
R73
0760
R04
00
1SV
R74
0760
R04
00
1SV
R73
0760
R05
00
Typ
e
CM
-SR
S.1
1S
CM
-SR
S.1
1P
CM
-SR
S.1
1S
CM
-SR
S.1
1P
CM
-SR
S.1
1S
CM
-SR
S.1
1P
CM
-SR
S.1
2S
CM
-SR
S.1
2S
CM
-SR
S.1
2S
CM
-SR
S.2
1S
CM
-SR
S.2
1P
CM
-SR
S.2
1S
CM
-SR
S.2
1P
CM
-SR
S.2
1S
CM
-SR
S.2
1P
CM
-SR
S.2
2S
CM
-SR
S.2
2S
CM
-SR
S.2
2S
CM
-SR
S.M
1S
CM
-SR
S.M
1P
CM
-SR
S.M
2S
CM
-SFS
.21S
CM
-SFS
.21P
CM
-SFS
.22S
Rated control supply voltage Us24 - 240 V AC/DC J J J J J J J J J J J J110 - 130 V AC J J J J J J220 - 240 V AC J J J J J JMeasuring ranges AC/DC
3 - 30 mA J J J J J J J J J J J J J J J J10 - 100 mA J J J J J J J J J J J J J J J J0.1 - 1 A J J J J J J J J J J J J J J J J0.3 - 1.5 A J J J J J J J J1 - 5 A J J J J J J J J3 - 15 A J J J J J J J JMonitoring function
Over- or undercurrent J J J J J J J J J J J J J J J J J J J J JWindows current monitoring J J JLatching sel sel sel sel sel sel
Open circuit or closed circuit principle sel sel sel sel sel sel
Timing functions for tripping delay
ON delay, 0 or 0. 1 - 30 s adj adj adj adj adj adj adj adj adj adj adj adj
ON or OFF delay sel sel sel
Output
c/o contact 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2
Connection type
Push-in terminals J J J J J J J JDouble-chamber cage connection terminals J J J J J J J J J J J J J J J J
Ord
er n
um
ber
1SV
R73
0830
R03
00
1SV
R74
0830
R03
00
1SV
R73
0831
R03
00
1SV
R74
0831
R03
00
1SV
R73
0831
R13
00
1SV
R74
0831
R13
00
1SV
R73
0830
R04
00
1SV
R74
0830
R04
00
1SV
R73
0831
R04
00
1SV
R74
0831
R04
00
1SV
R73
0831
R14
00
1SV
R74
0831
R14
00
1SV
R73
0830
R05
00
1SV
R74
0830
R05
00
1SV
R73
0750
R04
00
1SV
R74
0750
R04
00
Typ
e
CM
-ES
S.1
S
CM
-ES
S.1
P
CM
-ES
S.1
S
CM
-ES
S.1
P
CM
-ES
S.1
S
CM
-ES
S.1
P
CM
-ES
S.2
S
CM
-ES
S.2
P
CM
-ES
S.2
S
CM
-ES
S.2
P
CM
-ES
S.2
S
CM
-ES
S.2
P
CM
-ES
S.M
S
CM
-ES
S.M
P
CM
-EFS
.2S
CM
-EFS
.2P
Rated control supply voltage Us24 - 240 V AC/DC J J J J J J J J110 - 130 V AC J J J J220 - 240 V AC J J J JMeasuring ranges AC/DC
3 - 30 V J J J J J J J J J J J J J J J J6 - 60 V J J J J J J J J J J J J J J J J30 - 300 V J J J J J J J J J J J J J J J J60 - 600 V J J J J J J J J J J J J J J J JMonitoring function
Over- or undervoltage J J J J J J J J J J J J J JWindows voltage monitoring J JLatching sel sel sel sel
Open circuit or closed circuit principle sel sel sel sel
Timing functions for tripping delay
ON delay, 0 or 0.1 - 30 s adj adj adj adj adj adj adj adj
ON or OFF delay sel sel
Output
c/o contact 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2
Connection type
Push-in terminals J J J J J J J JDouble-chamber cage connection terminals J J J J J J J J
stock items adj: adjustable sel: selectable
stock items adj: adjustable sel: selectable
1SVR730... and 1SVR740...
-
22
10 ABB | EPR Selection Tables | 1SXP110002C0201 1SXP110002C0201 | EPR Selection Tables | ABB 11
Measuring and Monitoring RelaysThree Phase Monitors - Single function
Measuring and Monitoring RelaysThree Phase Monitors - Multifunctional
Ord
er n
um
ber
1SV
R55
0881
R94
00
1SV
R55
0882
R95
00
1SV
R55
0870
R94
00
1SV
R55
0871
R95
00
1SV
R55
0824
R91
00
1SV
R73
0824
R93
00
1SV
R74
0824
R93
00
1SV
R73
0784
R23
00
1SV
R74
0784
R23
00
1SV
R73
0784
R33
00
1SV
R74
0784
R33
00
1SV
R73
0794
R13
00
1SV
R73
0794
R13
00
1SV
R73
0794
R33
00
1SV
R74
0794
R33
00
1SV
R73
0794
R23
00
1SV
R74
0794
R23
00
1SV
R73
0774
R13
00
1SV
R74
0774
R13
00
1SV
R73
0774
R33
00
1SV
R74
0774
R33
00
Rated control supply voltage Usand measuring circuit T
ype
CM
-PB
E
CM
-PB
E
CM
-PV
E
CM
-PV
E
CM
-PFE
CM
-PFS
.S
CM
-PFS
.P
CM
-PS
S.3
1S
CM
-PS
S.3
1P
CM
-PS
S.4
1S
CM
-PS
S.4
1P
CM
-PV
S.3
1S
CM
-PV
S.3
1P
CM
-PV
S.4
1S
CM
-PV
S.4
1P
CM
-PV
S.8
1S
CM
-PV
S.8
1P
CM
-PA
S.3
1S
CM
-PA
S.3
1P
CM
-PA
S.4
1S
CM
-PA
S.4
1P
Phase to phase
160-300 V AC J J J J200-400 V AC J J200-500 V AC J J208-440 V AC J300-500 V AC J J J J320-460 V AC J J380 V AC J J380-440 V AC J J400 V AC J JPhase to neutral
185-265 V AC J220-240 V AC JRated frequency50/60 Hz J J J J J J J J J J J J J J J J J J J J JSuitable for monitoring
Single-phase mains J JThree-phase mains J J J J J J J J J J J J J J J J J J J J JMonitoring function
Phase failure J J J J J J J J J J J J J J J J J J J J JPhase sequence J J J sel sel sel sel sel sel sel sel sel sel J J J JAutomatic phase sequence correction
Overvoltage J J J J J J J J J J J JUndervoltage J J J J J J J J J J J JUnbalance J J J JNeutral 1) J JThresholds fix fix fix fix fix fix fix fix fix fix fix fix fix adj adj adj adj adj adj adj adj
Timing functions for tripping delay
ON delay fix fix sel sel sel sel
On and OFF delay fix fix fix fix fix adj adj adj adj adj adj adj adj adj adj
Connection type
Push-in terminals J J J J J J JDouble-chamber cage connection terminals J J J J J J J
adj: adjustablesel: selectablefix: fixed
adj: adjustablesel: selectable
Ord
er n
um
ber
1SV
R73
0885
R13
00
1SV
R74
0885
R13
00
1SV
R73
0885
R33
00
1SV
R74
0885
R33
00
1SV
R73
0884
R13
00
1SV
R74
0884
R13
00
1SV
R73
0884
R33
00
1SV
R74
0884
R33
00
1SV
R73
0885
R43
00
1SV
R74
0885
R43
00
1SV
R73
0884
R43
00
1SV
R74
0884
R43
00
1SV
R75
0487
R83
00
1SV
R76
0487
R83
00
1SV
R75
0488
R83
00
1SV
R76
0488
R83
00
1SV
R75
0489
R83
00
1SV
R76
0489
R83
00
Rated control supply voltage Usand measuring circuit T
ype
CM
-MP
S.1
1S
CM
-MP
S.1
1P
CM
-MP
S.2
1S
CM
-MP
S.2
1P
CM
-MP
S.3
1S
CM
-MP
S.3
1P
CM
-MP
S.4
1S
CM
-MP
S.4
1P
CM
-MP
S.2
3S
CM
-MP
S.2
3P
CM
-MP
S.4
3S
CM
-MP
S.4
3P
CM
-MP
N.5
2S
CM
-MP
N.5
2P
CM
-MP
N.6
2S
CM
-MP
N.6
2P
CM
-MP
N.7
2S
CM
-MP
N.7
2P
Phase to Phase
160-300 V AC J J300-500 V AC J J J J350-580 V AC J J450-720 V AC J J530-820 V AC J JPhase to Neutral
90-170 V AC J J180-280 V AC J J J JRated frequency50/60 Hz J J J J J J J J J J J J J J50/60/400 Hz J J J JSuitable for monitoring
Single-phase mains J J J J J JThree-phase mains J J J J J J J J J J J J J J J J J JMonitoring function
Phase failure J J J J J J J J J J J J J J J J J JPhase sequence sel sel sel sel sel sel sel sel adj adj adj adj adj adj adj adj adj adj
Automatic phase sequence correction adj adj adj adj adj adj adj adj adj adj
Overvoltage J J J J J J J J J J J J J J J J J JUndervoltage J J J J J J J J J J J J J J J J J JUnbalance J J J J J J J J J J J J J J J J J JNeutral 1) J2) J2) J2) J2) J2) J2)
Thresholds adj adj adj adj adj adj adj adj adj adj adj adj adj adj adj adj adj adj
Timing functions for tripping delay
On and OFF delay adj adj adj adj adj adj adj adj adj adj adj adj adj adj adj adj adj adj
Connection type
Push-in terminals J J J J J J J J JDouble-chamber cage connection terminals J J J J J J J J J
1) The external conductor voltage towards the neutral conductor is measured.2) Interrupted neutral monitoring
1) The external conductor voltage towards the neutral conductor is measured. 113.4 4.4722.5 0.89
85.6
3.37
103.7 4.08
105.9 4.17
114.5 4.51
45.0 1.77
85.6
3.37
104.8 4.13
107.0 4.21
1SVR550... 1SVR730... and 1SVR740... 1SVR750... and 1SVR760...
stock items
stock items
-
22
12 ABB | EPR Selection Tables | 1SXP110002C0201 1SXP110002C0201 | EPR Selection Tables | ABB 13
Insulation monitors for unearthed supply systems (IT-Systems)L1
L2
L3
N
PE
M
A1 11 S2 S321 S1
L+ V12 14A2V1-V1+
22 24 L- K
Consumer3~
w
Measuring and Monitoring RelaysInsulation Monitoring Relays
CM-IWN.x
Measuring and Monitoring RelaysMotor Load Monitoring Relays
Ord
er n
um
ber
1SV
R45
0335
R00
00
1SV
R45
0330
R00
00
1SV
R45
0331
R00
00
1SV
R45
0332
R00
00
1SV
R45
0334
R00
00
1SV
R45
0335
R01
00
1SV
R45
0330
R01
00
1SV
R45
0331
R01
00
1SV
R45
0332
R01
00
1SV
R45
0334
R01
00
Typ
e
CM
-LW
N
CM
-LW
N
CM
-LW
N
CM
-LW
N
CM
-LW
N
CM
-LW
N
CM
-LW
N
CM
-LW
N
CM
-LW
N
CM
-LW
N
Rated control supply voltage Us24 - 240 VAC/DC J J110 - 130 V AC J J220 - 240 V AC J J380 - 440 V AC J J480 - 500 V AC J JVoltage range (Phase to phase)
110- 500 V J J J J J J J J J JCurrent range
0.5 - 5 A J J J J J2 - 20 A J J J J JFrequency range
50/60 Hz J J J J J J J JDC or 15 - 400 Hz J JSuitable for monitoring
Single-phase mains J J J J J J J J J JThree-phase mains J J J J J J J J J JMonitoring function
Motor load // cos Phi J J J J J J J J J JTiming functions
Start up delay (on delay) adj adj adj adj adj adj adj adj adj adjResponse delay adj adj adj adj adj adj adj adj adj adjOutput contacts
2 x 1 c/o J J J J J J J J J J
Ord
er n
um
ber
1SV
R73
0670
R02
00
1SV
R74
0670
R02
00
1SV
R73
0660
R01
00
1SV
R74
0660
R01
00
1SV
R75
0660
R02
00
1SV
R76
0660
R02
00
1SV
R75
0660
R03
00
1SV
R76
0660
R03
00
1SV
R75
0660
R04
00
1SV
R76
0660
R04
00
1SV
R75
0660
R05
00
1SV
R76
0660
R05
00
Typ
e
CM
-IW
S.2
S
CM
-IW
S.2
P
CM
-IW
S.1
S
CM
-IW
S.1
P
CM
-IW
N.1
S
CM
-IW
N.1
P
CM
-IW
N.4
S
CM
-IW
N.4
P
CM
-IW
N.5
S
CM
-IW
N.5
P
CM
-IW
N.6
S
CM
-IW
N.6
P
Rated control supply voltage Us24 - 240 VAC/DC J J J J J J J J J J J JMeasuring voltages
250 V AC (L-PE) J J400 V AC (L-PE) J J J J J J J J J J690 V AC (L-PE) J1) J1) J1) J1) J1) J1) J1) J1)300 V DC (L-PE) J J600 V DC (L-PE) J J J J J J J J1000 V DC (L-PE) J1) J1) J1) J1) J1) J1) J1) J1)Measuring range
1 - 100 k J J J J J J J J J J J J2 - 200 k J J J J J J J JSystem leakage capacitance, max.
10 F J J J J20 F J J500 F J J1000 F J J2000 F J JOutput
1 c/o J J J J1 x 2 c/o or 2 x 1 c/o J J J J J J J JOperating principle
Open-circuit principle J J J JOpen- or closed-circuit principle adjustable J J J J J J J JTest
Front face button or control input J J J J J J J J J J J JReset
Front-face button or control input J J J J J J J J J J J JFault storage / latching configurable J J J J J J J J J J J JNon volatile storage configurable J J J J J J J J J J J JInterrupted wire detection J J J J J J J JThreshold values configurable 1 1 1 1 2 2 2 2 2 2 2 2
1) With coupling unit CM-IVNscrew version CM-IVN.S: 1SVR750669R9400
push-in version CM-IVN.P: 1SVR760669R9400
stock item
-
22
14 ABB | EPR Selection Tables | 1SXP110002C0201 1SXP110002C0201 | EPR Selection Tables | ABB 15
Temperature sensor C011, standard version acc. to DIN 44081
Type Rated response temperature TNF Color coding Order code Pack.-unit set
C011-70 70 C white-brown GHC0110003R0001 1
C011-80 80 C white-white GHC0110003R0002 1
C011-90 90 C green-green GHC0110003R0003 1
C011-100 100 C red-red GHC0110003R0004 1
C011-110 110 C brown-brown GHC0110003R0005 1
C011-120 120 C gray-gray GHC0110003R0006 1
C011-130 130 C blue-blue GHC0110003R0007 1
C011-140 140 C white-blue GHC0110003R0011 1
C011-150 150 C black-black GHC0110003R0008 1
C011-160 160 C blue-red GHC0110003R0009 1
C011-170 170 C white-green GHC0110003R0010 1
Triple temperature sensor C011-3
Type Rated response temperature TNF Color coding Order code Pack.-unit pieces
C011-3-150 150 C black-black GHC0110033R0008 1
Measuring and Monitoring RelaysThermistor Relays
Measuring and Monitoring RelaysTemperature Monitoring Relays
Ord
er n
um
ber
1SV
R73
0740
R91
00
1SV
R74
0740
R91
00
1SV
R73
0740
R01
00
1SV
R74
0740
R01
00
1SV
R73
0740
R92
00
1SV
R74
0740
R92
00
1SV
R73
0740
R02
00
1SV
R74
0740
R02
00
1SV
R73
0740
R93
00
1SV
R74
0740
R93
00
1SV
R73
0740
R03
00
1SV
R74
0740
R03
00
1SA
R70
0016
R00
05
1SA
R70
0016
R00
10
1SA
R70
0016
R00
10
Typ
e
CM
-TC
S.2
1S
CM
-TC
S.2
1P
CM
-TC
S.1
1S
CM
-TC
S.1
1P
CM
-TC
S.2
2S
CM
-TC
S.2
2P
CM
-TC
S.1
2S
CM
-TC
S.1
2P
CM
-TC
S.2
3S
CM
-TC
S.2
3P
CM
-TC
S.1
3S
CM
-TC
S.1
3P
C51
2-24
C51
2-W
C51
3-W
Rated control supply voltage Us24 V AC/DC J J J J J J J24-240 V AC/DC J J J J J J J JTechnology
Analogue J J J J J J J J J J J JDigital J J JSensor circuits (2 or 3 wire)
No of temperature sensors 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3No of thresholds 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3
Sensor type
PT100 J J J J J J J J J J J J J J JPT100, KTY83, KTY84, NTC J J JMeasuring temperature range
-50...+50 C J J J J0...+100 C J J J J0...+200 C J J J J-50...+500 C J J JMonitoring function
Overtemperature J J J J J J J J J J J J J J JUndertemperature J J J J J J J J J J J J J J JWindow temperature J J J J J J J J J J J J J J JOperating principleOpen or closed principle J J J J J J J J J J J J J J JOutput contactsn/o 1 1 1
c/o 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2
Ord
er c
od
e
1SV
R74
0720
R14
00
1SV
R73
0720
R14
00
1SV
R74
0700
R01
00
1SV
R73
0700
R01
00
1SV
R74
0700
R21
00
1SV
R73
0700
R21
00
1SV
R74
0722
R14
00
1SV
R73
0722
R14
00
1SV
R74
0700
R02
00
1SV
R73
0700
R02
00
1SV
R74
0700
R22
00
1SV
R73
0700
R22
00
1SV
R74
0712
R14
00
1SV
R73
0712
R14
00
1SV
R74
0712
R02
00
1SV
R73
0712
R02
00
1SV
R74
0712
R22
00
1SV
R73
0712
R22
00
1SV
R74
0712
R12
00
1SV
R73
0712
R12
00
1SV
R74
0712
R13
00
1SV
R73
0712
R13
00
Typ
e
CM
-MS
S.1
1P
CM
-MS
S.1
1S
CM
-MS
S.1
2P
CM
-MS
S.1
2S
CM
-MS
S.1
3P
CM
-MS
S.1
3S
CM
-MS
S.2
1P
CM
-MS
S.2
1S
CM
-MS
S.2
2P
CM
-MS
S.2
2S
CM
-MS
S.2
3P
CM
-MS
S.2
3S
CM
-MS
S.3
1P
CM
-MS
S.3
1S
CM
-MS
S.3
2P
CM
-MS
S.3
2S
CM
-MS
S.3
3P
CM
-MS
S.3
3S
CM
-MS
S.4
1P
CM
-MS
S.4
1S
CM
-MS
S.5
1P
CM
-MS
S.5
1S
Characteristics
ATEX approval n n n n n n n n n n n n n nNumber of sensor circuits 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2
Single or accumulative evaluation n nNumber of LEDs 3 3 2 2 2 2 3 3 2 2 2 2 3 3 3 3 3 3 3 3 3 3
Contacts
1 c/o (SPDT) contact n n n n2 c/o (SPDT) contacts n n n n n n n n n n1 n/c and 1 n/o n n n n n n2 x 1 c/o or 1 x 2 c/o contacts, configurable n nReset
Manual n n n n n n n n n n n n n nRemote n n n n n n n n n n n n n nAuto n n n n n n n n n1) n1) n1) n1) n1) n1) n1) n1) n1) n1) n1) n1) n2) n2)Functions
Short-circuit detection n n n n n n n nShort-circuit detection, configurable n n n nDynamic interrupted wire detection n n n n n n n n n n n n n nNon-volatile fault storage n n n n n nNon-volatile fault storage, configurable n n n nRated control supply voltage US24-240 V AC/DC n n n n n n n n n n24 V AC/DC n n n n n n110-130 V AC, 220-240 V AC n n n n n n
1) For automatic reset, jumper terminals S1-T2.2) For automatic reset, jumper terminals S1-1T2/2T2. stock items
stock item
-
22
16 ABB | EPR Selection Tables | 1SXP110002C0201 1SXP110002C0201 | EPR Selection Tables | ABB 17
Measuring and Monitoring RelaysLiquid Level Monitoring Relays
Accessories electrodes
Type Description Order code Pack. unit pieces
CM-KH-3 Compact support for 3 bar electrodes 1SVR450056R6000 1
CM-AH-3 Distance plate for 3 bar electrodes 1SVR450056R7000 1
CM-GM-1 Counter nut for 1 thread 1SVR450056R8000 1
Screw-in bar electrodes / Suspension electrode
CM-SE-300 300 mm 1SVR450056R0000 1
CM-SE-600 600 mm 1SVR450056R0100 1
CM-SE-1000 1000 mm 1SVR450056R0200 1
CM-HE - 1SVR402902R0000 1
Ord
er n
um
ber
1SV
R55
0855
R95
00
1SV
R55
0850
R95
00
1SV
R55
0851
R95
00
1SV
R55
0855
R94
00
1SV
R55
0850
R94
00
1SV
R55
0851
R94
00
1SV
R43
0811
R93
00
1SV
R43
0851
R01
00
1SV
R43
0851
R11
00
1SV
R43
0851
R13
00
1SV
R43
0851
R92
00
1SV
R43
0851
R02
00
1SV
R45
0055
R00
00
1SV
R45
0059
R00
00
1SV
R45
0050
R00
00
1SV
R45
0051
R00
00
1SV
R45
0059
R01
00
1SV
R45
0050
R01
00
1SV
R45
0051
R01
00
Typ
e
CM
-EN
E M
IN
CM
-EN
E M
IN
CM
-EN
E M
IN
CM
-EN
E M
AX
CM
-EN
E M
AX
CM
-EN
E M
AX
CM
-EN
S
CM
-EN
S
CM
-EN
S
CM
-EN
S
CM
-EN
S U
P/D
OW
N
CM
-EN
S U
P/D
OW
N
CM
-EN
N
CM
-EN
N
CM
-EN
N
CM
-EN
N
CM
-EN
S U
P/D
OW
N
CM
-EN
S U
P/D
OW
N
CM
-EN
S U
P/D
OW
N
Rated control supply voltage Us24 - 240 V AC/DC J24 V AC J J J J J J110 - 130 V AC J J J J J J220 - 240 V AC J J J J J JSensor circuits
No of electrodes
(including ground reference) 2 2 2 2 2 2 3 3 3 3 3 3 3 3 3 3 5 5 5
Response sensititvity
0 - 100 kOhm J J J J J J5 - 100 kOhm adj adj adj adj adj adj adj adj adj
250 Ohm - 5 kOhm adj adj adj adj
2,5 - 50 KOhm adj adj adj adj
25 - 500 kOhm adj adj adj adj
Monitoring function
Dry-running protection J J JOverflow protection J J JLiquide level control J J J J J J J J J J J J JOperating principle
Open circuit principle J J J J J J J J J J JClosed circuit principle J J JOpen or closed circuit principle sel sel sel sel sel
Output contacts
n/o 1 1 1 1 1 1 1
n/c 1 2 2 2
c/o 1 1 1 1 1 2 2 2 2 1 1 1
Measuring and Monitoring RelaysAccessories
2CD
C 2
52 1
87 F
0005
4,5 62,5
60
1011
,5
22,5
.177
2.46
2.36
.394
.886
.453
203A11 8 .31
5
.787
2CD
C 2
52 1
86 F
0005
2CD
C 2
52 1
85 F
000522,5
68,5
73,5
.886
2.70
.138.275
front-to-backsize 107
1SV
C 1
10 0
00 F
018
0
ADP.01
MAR.01
Sealable cover
COV.01
Sealable cover
COV.02
Ordering detailsDescription For type Width in
mmfor devices Type Order code Pkg
qtyWeight(1 pce)g (oz)
Adapter for screw mounting
CM-S 22.5 ADP.01 1SVR430029R0100 1 18.4 (0.65)
CM-N 45 ADP.02 1SVR440029R0100 1 36.7 (1.30)
Marker label
CM-S, CM-N 20
without DIP switches MAR.01 1SVR366017R0100 10
0.19 (0.007)
CM-S, CM-N 20
with DIPswitches MAR.02 1SVR430043R0000 10
0.13 (0.005)
Sealabletransparent cover
CM-S 22.5 COV.01 1SVR430005R0100 1 5.2 (0.18)
CM-S.S/P 22.5 COV.11 1SVR730005R0100 1 4.0 (0.129)
CM-N.S/P 45 COV.12 1SVR750005R0100 1 7 (0.247)
stock item adj: adjustable sel: selectable
-
33
18 ABB | EPR Selection Tables | 1SXP110002C0201 1SXP110002C0201 | EPR Selection Tables | ABB 19
Switch Mode Power SuppliesCP Range - Single phase
Switch Mode Power SuppliesCP Range - Three phase and AS-interface
Ord
er n
um
ber
1SV
R42
7041
R10
00
1SV
R42
7043
R12
00
1SV
R42
7041
R00
00
1SV
R42
7043
R01
00
1SV
R42
7044
R02
00
1SV
R42
7045
R04
00
1SV
R42
7033
R30
00
1SV
R42
7032
R10
00
1SV
R42
7035
R10
00
1SV
R42
7030
R00
00
1SV
R42
7031
R00
00
1SV
R42
7032
R00
00
1SV
R42
7034
R00
00
1SV
R42
7035
R00
00
1SV
R42
7036
R00
00
1SV
R42
7030
R20
00
1SV
R42
7031
R20
00
1SV
R42
7034
R00
00
1SV
R42
7035
R20
00
1SV
R42
7014
R00
00
1SV
R42
7015
R01
00
1SV
R42
7016
R01
00
1SV
R42
7024
R00
00
1SV
R42
7025
R00
00
1SV
R42
7026
R00
00
Single phase
CP-D CP-E CP-S CP-C
Rated output voltage 5 V DC 12 V DC 24 V DC 48 V DC
Rated output current 0.42 A 0.625 A
0.75 A 0.83 A 1.25 A
1.3 A 2.1 A 2.5 A
3 A 4.2 A
5 A 10 A 20 A
Rated output power 10 W 15 W 18 W 30 W 60 W
100 W 120 W 240 W 480 W
Rated input
voltage
100 - 240 V AC 115/230 V AC auto select
115 - 230 V AC 110 - 240 V AC 110 - 120 V AC 220 - 240 V AC
DC input
voltage range
120 - 370 V DC 90 - 375 V DC
210 - 370 V DC 100 - 350 V DC 220 - 350 V DC
Features Power reserve design Adjustable output voltage
Integrated input fuse Short circuit stable
Fold forward behavior (U/I) Fold back behavior (hiccup)
Power factor correction pas pas pas act pas act act act actAmbient temp. rating
-25C (-40C) to 70C
Parallel connection 3 3 3 3 3 3 5 5 5 5 5 5Serial connection 2 2 2 2 2 2
Ord
er n
um
ber
1SV
R42
7054
R00
00
1SV
R42
7055
R00
00
1SV
R42
7056
R00
00
1SV
R42
7057
R00
00
1SV
R42
7054
R20
00
1SV
R42
7055
R20
00
1SV
R42
7056
R20
00
1SV
R42
7090
R02
80
1SV
R42
7090
R04
00
1SV
R42
7095
R04
00
1SV
R42
7090
R08
00
Three phase AS-Interface
CP-T CP-ASI
Rated output voltage 24 V DC 30.5 V DC
48 V DC Rated output current 2.8 A
3 A 5 A 8 A
10 A 20 A 40 A
Rated output power 85 W 120 W 122 W 240 W 244 W 480 W 960 W
Rated input
voltage
85-132 V AC, 184-264 V AC 3 x 400 - 500 V AC
DC input
voltage range
18-32.4 V DC 480 - 820 V DC
Features Adjustable output voltage Integrated input fuse
Short circuit stable Fold forward behavior (U/I) Fold back behavior (hiccup)
Power factor correctionAmbient temp. rating -25C
(-40C) to 70C
Serial connection 2 2 2 2 2 2Suited for AS-Interfaces
stock items pas: passive act: active
-
33
20 ABB | EPR Selection Tables | 1SXP110002C0201 1SXP110002C0201 | EPR Selection Tables | ABB 21
Selection table
Rated current Inin (A)
Type code Order number bbn40 16779 EAN
Weight1 piece (kg)
Packunit pc.
0.5 EPD24-TB-101-0.5A 2CDE601101R2905 829960 0.065 4
1 EPD24-TB-101-1A 2CDE601101R2001 829984 0.065 4
2 EPD24-TB-101-2A 2CDE601101R2002 830003 0.065 4
3 EPD24-TB-101-3A 2CDE601101R2003 830027 0.065 4
4 EPD24-TB-101-4A 2CDE601101R2004 830041 0.065 4
6 EPD24-TB-101-6A 2CDE601101R2006 830065 0.065 4
8 EPD24-TB-101-8A 2CDE601101R2008 830089 0.065 4
10 EPD24-TB-101-10A 2CDE601101R2010 830102 0.065 4
12 EPD24-TB-101-12A 2CDE601101R2012 830126 0.065 4
Selection table accessories EPD24
Type code Order number bbn40 16779 EAN
Weight1 piece (kg)
Packunit pc.
Busbars for LINE+ and 0 V, grey insulation, length 500 mm 1)
EPD-BB500 2CDE605100R0500 830140 0.20 10
Signal Bars for aux. contacts, grey insulation, length 21 mm
EPD-SB21 2CDE605200R0021 830164 0.04 10
1) Max. load with one line entry Imax = 50 A (recommended: center-feeding)
Max. load with two line entries Imax = 63 A
Electronic Protection Devices EPD24
Selection table Type CP-B 24/3.0 CP-B 24/10.0 CP-B 24/20.0 CP-B EXT.2 Order code 1SVR427060R0300 1SVR427060R1000 1SVR427060R2000 1SVR427065R0000
Rated input voltage 24 V DC 24 V DC 24 V DC -
Rated current 3 A DC 10 A DC 20 A DC -
Energy storage (min.) 1000 Ws 10000 Ws 8000 Ws 2000 Ws
Typical
charging time 100 % 65 s 120 s 68 s
at load current 0 % 56 s 82 s 62 s
Typical buffer time1)
at load current 100 % 14 s 40 s 15 s
50 % 28 s 80 s 30 s
25 % 74 s 140 s 60 s
10 % 148 s 380 s 150 s 1) buffer time =
energy storage x 0.9 current x 23 V
Buffer modules CP-B range
Type Order number
CP-A RU Redundancy module 40 V; 5A 1SVR427071R0000
CP-A CM Control module for CP-A 1SVR427075R0000
CP-Range
Switch Mode Power SuppliesAccessories
Switch Mode Power SuppliesAccessories
-
44
22 ABB | EPR Selection Tables | 1SXP110002C0201 1SXP110002C0201 | EPR Selection Tables | ABB 23
Su
pp
ly v
olt
age
Us
24 V
DC
110
- 24
0 V
AC
24 -
48
V D
C
24 V
AC
100
- 30
0 V
DC
Inp
ut
sig
nal
Pot
entio
met
er
0 -
0 V
0 -
50 m
V
0 -
100
mV
0 -
125
mV
0 -
250
mV
0 -
500
mV
0 -
1 V
0 -
2,5
V
0 -
5 V
0 -
8 V
0 -
10 V
1 -
5 V
2 -
10 V
-10
- +
10 V
-22.
5 -
+22
.5 m
V
-11
- +
11 V
2.5
- 7.
5 V
3.33
- 9
.99
V
10 -
0 V
100
- 0
mV
0 -
1 m
A
0 -
20 m
A
4 -
20 m
A
10 -
50
mA
20 -
4 m
A
20 -
0 m
A
-0.4
5 -
+0.
45 m
A
-55
- +
55 m
A
Ou
tpu
t si
gn
al
0 -
5 V
0 -
10 V
1 -
5 V
2 -
10 V
-10
- +
10 V
-5 -
+5
V
-10
- 0
V
-5 -
0 V
0 -
6.66
6 V
-10
- +
3.33
V
-5 -
+1.
66 V
0 -
8 V
0 -
4 V
-10
- -2
V
-5 -
-1
V
1.25
- 6
.25
V
-7.5
- +
2.5
V
-3.7
5 -
+1.
25 V
1.66
- 8
.33
V
-6.6
6 -
+6.
66 V
-3.3
3 -
+3.
33 V
-8 -
0 V
-4 -
0 V
0 -
1 m
A
0 -
20 m
A
4 -
20 m
A
0 -
10 m
A
0 -
0.5
mA
0 -
13.3
3 m
A
0 -
666
A
0 -
16 m
A
0 -
800
A
0 -
8 m
A
0 -
400
A
2.5
- 12
.5 m
A
125
- 62
5 A
3.33
- 1
6.66
mA
166
- 83
3 A
0.2
- 1
mA
2 -
10 m
A
100
- 50
0 A
Rel
ay o
utp
ut
Analogue Signal ConvertersCC Range
Standard SignalConverters
Type Order number
CC-E/STD 1SVR011700R0000 J J J J J J J J J CC-E V/V 1SVR011710R2100 J J J CC-E V/I 1SVR011711R1600 J J J CC-E V/I 1SVR011712R1700 J J J CC-E I/V 1SVR011713R1000 J J J CC-E I/I 1SVR011714R1100 J J J CC-E I/I 1SVR011715R1200 J J J CC-E I/V 1SVR011716R1300 J J J CC-E I/I 1SVR011717R1400 J J J CC-E I/I 1SVR011718R2500 J J J CC-E V/V 1SVR011719R2600 J J J CC-E/STD 1SVR011705R2100 J J J J J J J J J CC-E V/V 1SVR011720R2300 J J J CC-E V/I 1SVR011721R1000 J J J CC-E V/I 1SVR011722R1100 J J J CC-E I/V 1SVR011723R1200 J J J CC-E I/I 1SVR011724R1300 J J J CC-E I/I 1SVR011725R1400 J J J CC-E I/V 1SVR011726R1500 J J J CC-E I/I 1SVR011727R1600 J J J CC-E I/I 1SVR011728R2700 J J J CC-E V/V 1SVR011729R2000 J J J CC-E/I-1 1SVR010200R1600 J J J J CC-E/I-2 1SVR010201R0300 2 2 2 2
CC-U/STD 1SVR040000R1700 J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J JCC-U/STD 1SVR040001R0400 J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J JCC-U/STDR 1SVR040010R0000 J J J J J J J J J 2CC-U/STDR 1SVR040011R2500 J J J J J J J J J 2
stock items
-
44
24 ABB | EPR Selection Tables | 1SXP110002C0201 1SXP110002C0201 | EPR Selection Tables | ABB 25
Type Order number
CC-E/RTD 1SVR011701R2500 J J J J J J J J J J CC-E RTD/V 1SVR011730R2500 J J J CC-E RTD/I 1SVR011731R1200 J J J CC-E RTD/I 1SVR011732R1300 J J J CC-E RTD/V 1SVR011733R1400 J J J CC-E RTD/I 1SVR011734R1500 J J J CC-E RTD/I 1SVR011735R1600 J J J CC-E RTD/V 1SVR011736R1700 J J J CC-E RTD/I 1SVR011737R1000 J J J CC-E RTD/I 1SVR011738R2100 J J J CC-E RTD/V 1SVR011739R2200 J J J CC-E RTD/I 1SVR011740R0700 J J J CC-E RTD/I 1SVR011741R2400 J J J CC-E/RTD 1SVR011706R2200 J J J J J J J J J J CC-E RTD/V 1SVR011788R2400 J J J CC-E RTD/I 1SVR011789R2500 J J J CC-E RTD/I 1SVR011790R2200 J J J CC-E RTD/V 1SVR011791R1700 J J J CC-E RTD/I 1SVR011792R1000 J J J CC-E RTD/I 1SVR011793R1100 J J J CC-E RTD/V 1SVR011794R1200 J J J CC-E RTD/I 1SVR011795R1300 J J J CC-E RTD/I 1SVR011796R1400 J J J CC-E RTD/V 1SVR011797R1500 J J J CC-E RTD/I 1SVR011798R2600 J J J CC-E RTD/I 1SVR011799R2700 J J J CC-U/RTD 1SVR040002R0500 J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J CC-U/RTD 1SVR040003R0600 J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J CC-U/RTDR 1SVR040012R2600 J J J J J J J 2 CC-U/RTDR 1SVR040013R2700 J J J J J J J 2
Temperature Signal ConvertersCC Range
RTD Converters
Su
pp
ly v
olt
age
Us
24 V
DC
110
- 24
0 V
AC
24 -
48
V D
C
24 V
AC
100
- 30
0 V
DC
Inp
ut
sig
na
l
0 -
50
C
P
T100
0 -
60
C
0 -
70
C
0 -
80
C
0 -
90
C
0 -
100
C
0 -
200
C
0 -
300
C
0 -
400
C
0 -
500
C
0 -
600
C
0 -
800
C
-50
C -
+50
C
-50
C -
+45
0 C
-50
C -
+25
0 C
0 -
500
C
P
T10
0 -
550
C
0 -
600
C
0 -
650
C
0 -
700
C
0 -
750
C
0 -
800
C
0 -
850
C
0 -
10
C
0 -
20
C
0 -
30
C
0 -
40
C
0 -
50
C
0 -
60
C
Ou
tpu
t si
gn
al
0 -
5 V
0 -
10 V
1 -
5 V
2 -
10 V
-10
- +
10 V
-5 -
+5
V
-10
- 0
V
-5 -
0 V
0 -
6.66
6 V
-10
- +
3.33
V
-5 -
+1.
66 V
0 -
8 V
0 -
4 V
-10
- -2
V
-5 -
-1
V
1.25
- 6
.25
V
-7.5
- +
2.5
V
-3.7
5 -
+1.
25 V
1.66
- 8
.33
V
-6.6
6 -
+6.
66 V
-3.3
3 -
+3.
33 V
-8 -
0 V
-4 -
0 V
0 -
1 m
A
0 -
20 m
A
4 -
20 m
A
0 -
10 m
A
0 -
0.5
mA
0 -
13.3
3 m
A
0 -
666
A
0 -
16 m
A
0 -
800
A
0 -
8 m
A
0 -
400
A
2.5
- 12
.5 m
A
125
- 62
5 A
3.33
- 1
6.66
mA
166
- 83
3 A
0.2
- 1
mA
2 -
10 m
A
100
- 50
0 A
Rel
ay o
utp
ut
stock items
PT1000
PT1
000
-
44
26 ABB | EPR Selection Tables | 1SXP110002C0201 1SXP110002C0201 | EPR Selection Tables | ABB 27
Thermocouple Signal ConvertersCC Range
ThermocoupleConverters
Type Order number
CC-E/TC 1SVR011702R2600 J J J J J JCC-E TC/V 1SVR011750R0100 J J J CC-E TC/I 1SVR011751R2600 J J JCC-E TC/I 1SVR011752R2700 J J JCC-E TC/V 1SVR011753R2000 J J J CC-E TC/I 1SVR011754R2100 J J J CC-E TC/I 1SVR011755R2200 J J J CC-E/TC 1SVR011707R2300 J J J J J J CC-E TC/V 1SVR011760R0300 J J J CC-E TC/I 1SVR011761R2000 J J J CC-E TC/I 1SVR011762R2100 J J J CC-E TC/V 1SVR011763R2200 J J J CC-E TC/I 1SVR011764R2300 J J J CC-E TC/I 1SVR011765R2400 J J J CC-U/TC 1SVR040004R0700 J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J JCC-U/TC 1SVR040005R0000 J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J JCC-U/TCR 1SVR040014R2000 J J J J J J J J J J J J J J J 2CC-U/TCR 1SVR040015R2100 J J J J J J J J J J J J J J J 2
typ
e K
typ
e K
typ
e K
typ
e J
typ
e J
typ
e T
typ
e T
typ
e S
typ
e E
typ
e E
typ
e N
typ
e N
typ
e R
typ
e R
typ
e B
mV
mV
typ
e J
typ
e J
typ
e J
typ
e K
typ
e K
typ
e K
typ
e T
typ
e T
typ
e T
typ
e S
typ
e S
typ
e S
typ
e S
Su
pp
ly v
olt
age
Us
24 V
DC
110
- 24
0 V
AC
24 -
48
V D
C
24 V
AC
100
- 30
0 V
DC
Inp
ut
sig
nal
010
00
C
0 -
100
- 90
0 C
0 -
250
- 13
50
C
0 -
600
C
0 -
100
- 75
0 C
0 -
100
- 40
0 C
-150
- 0
- 4
00
C
0 -
250
- 15
50
C
0 -
100
- 70
0 C
0 -
200
- 10
00
C
0 -
100
- 65
0 C
0 -
200
- 13
00
C
0 -
250
- 13
50
C
0 -
450
- 17
00
C
0 -
700
- 17
50
C
0 -
2 -
10 m
V
0 -
10 -
50
mV
0 -
240
C
0 -
480
C
0 -
1200
C
0 -
250
C
0 -
500
C
0 -
1350
C
-150
- +
120
C
0 -
220
C
0 -
400
C
0 -
210
C
0 -
380
C
0 -
860
C
0 -
1550
C
Ou
tpu
t si
gn
al
0 -
5 V
0 -
10 V
1 -
5 V
2 -
10 V
-10
- +
10V
-5 -
+5
V
-10
- 0
V
-5 -
0 V
0 -
6.66
6 V
-10
- +
3.33
V
-5 -
+1.
66 V
0 -
8 V
0 -
4 V
-10
- -2
V
-5 -
-1
V
1.25
- 6
.25
V
-7.5
- +
2.5
V
-3.7
5 -
+1.
25 V
1.66
- 8
.33
V
-6.6
6 -
+6.
66 V
-3.3
3 -
+3.
33 V
-8 -
0 V
-4 -
0 V
0 -
1 m
A
0 -
20 m
A
4 -
20 m
A
0 -
10 m
A
0 -
0.5
mA
0 -
13.3
3 m
A
0 -
666
A
0 -
16 m
A
0 -
800
A
0 -
8 m
A
0 -
400
A
2.5
- 12
.5 m
A
125
- 62
5 A
3.33
- 1
6.66
mA
166
- 83
3 A
0.2
- 1
mA
2 -
10 m
A
100
- 50
0 A
Rel
ay o
utp
ut
stock item
-
44
28 ABB | EPR Selection Tables | 1SXP110002C0201 1SXP110002C0201 | EPR Selection Tables | ABB 29
Measuring ConvertersCC Range
Type Order number
CC-E/I 1SVR011703R2700 J J J J J J J JCC-E IAC/V 1SVR011770R0500 J J J J CC-E IAC/I 1SVR011771R2200 J J J J CC-E IAC/I 1SVR011772R2300 J J J J CC-E IDC/V 1SVR011773R2400 J J J J CC-E IDC/I 1SVR011774R2500 J J J J CC-E IDC/I 1SVR011775R2600 J J J J CC-E/I 1SVR011708R0400 J J J J J J J J CC-E IAC/V 1SVR011780R1100 J J J J CC-E IAC/I 1SVR011781R0600 J J J J CC-E IAC/I 1SVR011782R0700 J J J J CC-E IDC/V 1SVR011783R0000 J J J J CC-E IDC/I 1SVR011784R0100 J J J J CC-E IDC/I 1SVR011785R1100 J J J J CC-E IAC/ILPO 1SVR010203R0500 J J J J CC-U/I 1SVR040006R0100 J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J JCC-U/I 1SVR040007R0200 J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J JCC-U/V 1SVR040008R1300 J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J JCC-U/V 1SVR040009R1400 J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J
Su
pp
ly v
olt
age
Us
24 V
DC
110
- 24
0 V
AC
24 -
48
V D
C
24 V
AC
100
- 30
0 V
DC
Inp
ut
sig
nal
0 -
1 A
, A
C
Cur
rent
0 -
5 A
, A
C
0 -
20 A
, A
C
0 -
5 A
, D
C
0 -
20 A
, D
C
0 -
100
V
Volta
ge
0 -
150
V
0 -
250
V
0 -
300
V
0 -
400
V
0 -
450
V
0 -
550
V
0 -
600
V
loop
pow
ered
any
wav
e fo
rm 0
-600
Hz
Ou
tpu
t si
gn
al
0 -
5 V
Vo
ltage
0 -
10 V
1 -
5 V
2 -
10 V
-10
- +
10 V
-5 -
+5
V
-10
- 0
V
-5 -
0 V
0 -
0.66
6 V
-10
- +
3.33
V
-5 -
+1.
66 V
0 -
8 V
0 -
4 V
-10
- -2
V
-5 -
-1
V
1.25
- 6
.25
V
-7.5
- +
2.5
V
-3.7
5 -
+1.
25 V
1.66
- 8
.33
V
-6.6
6 -
+6.
66 V
-3.3
3 -
+3.
33 V
-8 -
0 V
-4 -
0 V
0 -
1 m
A
Cur
rent
0 -
20 m
A
4 -
20 m
A
0 -
10 m
A
0 -
0.5
mA
0 -
13.3
3 m
A
0 -
666
A
0 -
16 m
A
0 -
800
A
0 -
8 m
A
0 -
400
A
2.5
- 12
.5 m
A
125
- 62
5 A
3.33
- 1
6.66
mA
166
- 83
3 A
0.2
- 1
mA
2 -
10 m
A
100
- 50
0 A
-
44
30 ABB | EPR Selection Tables | 1SXP110002C0201 1SXP110002C0201 | EPR Selection Tables | ABB 31
Serial Data ConvertersILPH
Application, Approvals and marks
Nearly every process includes a control system that receives data by means of analog signals and then evaluates the data and sets the respective parameters correspondingly. When transmitting analog signals numerous problems may arise which can disturb or even block an ideal behavior of the process.Below we have listed some processing problems together with the respective solutions to solve these problems:
Signal conversionSometimes the available signal cannot be processed by the controller or the actuator. In this case, signal converters are required to convert the input signal to the desired output signal.
Signal amplificationIf long lines or high burdens have to be operated, it may be necessary to amplify the signal. CC analog signal converters require only low input power and provide high output power. Thus, there are no restrictions for the converter's position on the line, i.e. it can be used
for signal refreshing at the end of the line (low input power)
or for signal amplification at the beginning of the line (high output power).
Signal filteringParticularly on long lines or in rough industrial environments the signals are exposed to high electromagnetic interferences. The frequency of the coupled interference signals may be in the range of the common mains frequency (50 Hz) or even much higher (in case of frequency converters). According to the specific requirements, analog signal converters are available which provide reliable suppression of those interferences by means of an input low-pass filter.
Applications for analog signal processing and correct solution using CC-E and CC-U converters
Signal separation
Protection against overvoltage The increased use of micro-electronics make controls much more sensitive against overvoltages, resulting from lightning discharges or switching processes. Suppression diodes are incorporated in the input of the CC analog signal converters which enable the converters to arrest overvoltages with low energy level (resulting from switching processes) by themselves. The products furthermore provide electrical isolation between input, output and supply circuit for protection of the controller connected to the output.
Protection against ground loopsIf components are used which refer to ground, the measuring signals can be falsified by a so-called ground loop. In this case, certain parts of the signal are transmitted via earth and not via the analog transmission line, thus causing incorrect evaluation of the signal. The electrical isolation between the input and the output disconnects these ground loops and thus enables correct signal transmission.
Approvals CC
-E/S
TD
CC
-E I/
I
CC
-U/S
TD
CC
-U/S
TDR
CC
-E/R
TD
CC
-U/R
TD
CC
-U/R
TDR
CC
-E/T
C
CC
-U/T
C
CC
-U/T
CR
CC
-E/I
CC
-E I A
C/IL
PO
CC
-U/I
CC
-U/V
A UL 508, CAN/CSA C22.2 No.14 J J J J J J J J J J J J J J
A UL 1604 (Class I, Div 2, hazardous locations), CAN/CSA C22.2 No.213 G J G J G J G J J
K CB scheme J J J
E CCC J J J
Marks
a CE J J J J J J J J J J J J J J
b C-Tick J J J J J J J J J J J J J J
J existing
G existing for some devices
0-10 V0-10 V
100 m 0-20 mA 100 m 4-20 mA
2CD
C 2
82 0
13 F
0206
Controllere.g. AC500
Measuring sensor
Actuator
1. Analog signal converter
(e.g. CC-E or CC-U)
2. Analog signal converter
(e.g. CC-E or CC-U)
Ord
er c
od
e
1SN
A68
4252
R02
00
1SN
A68
4231
R25
00
1SN
A68
4233
R27
00
1SN
A68
4333
R23
00
1SN
A68
4334
R24
00
1SN
A68
4234
R20
00
1SN
A68
4212
R22
00
1SN
A68
4236
R22
00
1SN
A68
4264
R04
00
1SN
A68
1232
R26
00
1SN
A68
4202
R01
00
Typ
e
ILP
H R
S 2
32-R
S 4
85 /
Eth
erne
t
ILP
H R
S 2
32 /
RS
422
-485
ILP
H R
S 2
32 /
RS
422
-485
ILP
H R
S 2
32 /
RS
422
-485
ILP
H R
S 2
32 /
RS
422
-485
ILP
H R
S 2
32 /
RS
232
ILP
H R
S 4
22 -
485
/ R
S 4
22 -
485
ILP
H R
S 2
32 /
FO
-S
ILP
H R
S 4
85 /
FO
-S
ILP
H B
dC /
RS
422
- 4
85
ILP
H R
S 2
32 /
BdC
Rated supply voltage us24 V DC n n n n n115 - 230 V AC n n24 - 42 V AC/DC n n10 - 34 V DC n10 - 24 V AC nInput signal
RS 232 n n n n n n n nRS 422 nRS 485 n n nCurrent loop nOutput signal
RS 232 nRS422 n n n n n nRS 485 n n n n n nCurrent loop nFiber optic glass n nEthernet nGalvanic isolation
3 way isolation n n n n n n n n n nNo isolation n
stock items
-
55
32 ABB | EPR Selection Tables | 1SXP110002C0201 1SXP110002C0201 | EPR Selection Tables | ABB 33
Pluggable Interface RelaysCR-M Range
Ord
er c
od
e
1SV
R40
5611
R40
00
1SV
R40
5611
R10
00
1SV
R40
5611
R60
00
1SV
R40
5611
R42
00
1SV
R40
5611
R80
00
1SV
R40
5611
R82
00
1SV
R40
5611
R90
00
1SV
R40
5611
R00
00
1SV
R40
5611
R50
00
1SV
R40
5611
R70
00
1SV
R40
5611
R20
00
1SV
R40
5611
R30
00
1SV
R40
5612
R40
00
1SV
R40
5612
R10
00
1SV
R40
5612
R60
00
1SV
R40
5612
R42
00
1SV
R40
5612
R80
00
1SV
R40
5612
R82
00
1SV
R40
5612
R90
00
1SV
R40
5612
R00
00
1SV
R40
5612
R50
00
1SV
R40
5612
R52
00
1SV
R40
5612
R70
00
1SV
R40
5612
R20
00
1SV
R40
5612
R30
00
1SV
R40
5613
R40
00
1SV
R40
5613
R10
00
1SV
R40
5613
R60
00
1SV
R40
5613
R42
00
1SV
R40
5613
R80
00
1SV
R40
5613
R82
00
1SV
R40
5613
R90
00
1SV
R40
5613
R00
00
1SV
R40
5613
R50
00
1SV
R40
5613
R70
00
1SV
R40
5613
R20
00
1SV
R40
5613
R30
00
1SV
R40
5611
R41
00
1SV
R40
5611
R11
00
1SV
R40
5611
R61
00
1SV
R40
5611
R43
00
1SV
R40
5611
R81
00
1SV
R40
5611
R83
00
1SV
R40
5611
R91
00
1SV
R40
5611
R01
00
1SV
R40
5611
R51
00
1SV
R40
5611
R71
00
1SV
R40
5611
R21
00
1SV
R40
5611
R31
00
1SV
R40
5612
R41
00
1SV
R40
5612
R11
00
1SV
R40
5612
R61
00
1SV
R40
5612
R43
00
1SV
R40
5612
R81
00
1SV
R40
5612
R83
00
1SV
R40
5612
R91
00
1SV
R40
5612
R01
00
1SV
R40
5612
R51
00
1SV
R40
5612
R71
00
1SV
R40
5612
R21
00
1SV
R40
5612
R31
00
1SV
R40
5613
R41
00
1SV
R40
5613
R11
00
1SV
R40
5613
R61
00
1SV
R40
5613
R43
00
1SV
R40
5613
R81
00
1SV
R40
5613
R83
00
1SV
R40
5613
R91
00
1SV
R40
5613
R01
00
1SV
R40
5613
R51
00
1SV
R40
5613
R71
00
1SV
R40
5613
R21
00
1SV
R40
5613
R31
00
1SV
R40
5614
R11
00
1SV
R40
5618
R10
00
1SV
R40
5618
R00
00
1SV
R40
5618
R70
00
1SV
R40
5618
R30
00
1SV
R40
5618
R41
00
1SV
R40
5618
R11
00
1SV
R40
5618
R61
00
1SV
R40
5618
R43
00
1SV
R40
5618
R81
00
1SV
R40
5618
R83
00
1SV
R40
5618
R91
00
1SV
R40
5618
R01
00
1SV
R40
5618
R51
00
1SV
R40
5618
R71
00
1SV
R40
5618
R21
00
1SV
R40
5618
R31
00
1SV
R40
5618
R44
00
1SV
R40
5618
R14
00
Typ
e
CR
-M01
2DC
2
CR
-M02
4DC
2
CR
-M04
8DC
2
CR
-M06
0DC
2
CR
-M11
0DC
2
CR
-M12
5DC
2
CR
-M22
0DC
2
CR
-M02
4AC
2
CR
-M04
8AC
2
CR
-M11
0AC
2
CR
-M12
0AC
2
CR
-M23
0AC
2
CR
-M01
2DC
3
CR
-M02
4DC
3
CR
-M04
8DC
3
CR
-M06
0DC
3
CR
-M11
0DC
3
CR
-M12
5DC
3
CR
-M22
0DC
3
CR
-M02
4AC
3
CR
-M04
8AC
3
CR
-M06
0AC
3
CR
-M11
0AC
3
CR
-M12
0AC
3
CR
-M23
0AC
3
CR
-M01
2DC
4
CR
-M02
4DC
4
CR
-M04
8DC
4
CR
-M06
0DC
4
CR
-M11
0DC
4
CR
-M12
5DC
4
CR
-M22
0DC
4
CR
-M02
4AC
4
CR
-M04
8AC
4
CR
-M11
0AC
4
CR
-M12
0AC
4
CR
-M23
0AC
4
CR
-M01
2DC
2L
CR
-M02
4DC
2L
CR
-M04
8DC
2L
CR
-M06
0DC
2L
CR
-M11
0DC
2L
CR
-M12
5DC
2L
CR
-M22
0DC
2L
CR
-M02
4AC
2L
CR
-M04
8AC
2L
CR
-M11
0AC
2L
CR
-M12
0AC
2L
CR
-M23
0AC
2L
CR
-M01
2DC
3L
CR
-M02
4DC
3L
CR
-M04
8DC
3L
CR
-M06
0DC
3L
CR
-M11
0DC
3L
CR
-M12
5DC
3L
CR
-M22
0DC
3L
CR
-M02
4AC
3L
CR
-M04
8AC
3L
CR
-M11
0AC
3L
CR
-M12
0AC
3L
CR
-M23
0AC
3L
CR
-M01
2DC
4L
CR
-M02
4DC
4L
CR
-M04
8DC
4L
CR
-M06
0DC
4L
CR
-M11
0DC
4L
CR
-M12
5DC
4L
CR
-M22
0DC
4L
CR
-M02
4AC
4L
CR
-M04
8AC
4L
CR
-M11
0AC
4L
CR
-M12
0AC
4L
CR
-M23
0AC
4L
CR
-M02
4DC
4LD
CR
-M02
4DC
4G
CR
-M02
4AC
4G
CR
-M11
0AC
4G
CR
-M23
0AC
4G
CR
-M01
2DC
4LG
CR
-M02
4DC
4LG
CR
-M04
8DC
4LG
CR
-M06
0DC
4LG
CR
-M11
0DC
4LG
CR
-M12
5DC
4LG
CR
-M22
0DC
4LG
CR
-M02
4AC
4LG
CR
-M04
8AC
4LG
CR
-M11
0AC
4LG
CR
-M12
0AC
4LG
CR
-M23
0AC
4LG
CR
-M01
2DC
4LD
G
CR
-M02
4DC
4LD
G
Input voltage
12 V DC 24 V DC 48 V DC 60 V DC 110 V DC 125 V DC 220 V DC 24 V AC 48 V AC 60 V AC 110 V AC 120 V AC 230 V AC Output rating
250 V 16 A
250 V 8 A
250 V 12 A 250 V 10 A 250 V 6 A Output contacts
c/o 2 2 2 2 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3 3 3 3 3 3 4 4 4 4 4 4 4 4 4 4 4 4 2 2 2 2 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3 3 3 3 3 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4
Gold contact LED Free-wheeling
diode
Accessories CR-M SocketsType Version Connection terminals Order code Pack. unit pieces
Sockets
CR-M2LS Logical socket for 2 c/o screw 1SVR405651R1100 10CR-M3LS Logical socket for 3 c/o screw 1SVR405651R2100 10CR-M4LS Logical socket for 2/4 c/o screw 1SVR405651R3100 10
CR-M2LC Logical socket for 2 c/o spring connection 1SVR405651R1200 10CR-M4LC Logical socket for 2/4 c/o spring connection 1SVR405651R3200 10CR-M2SS Standard socket for 2 c/o screw 1SVR405651R1000 10CR-M3SS Standard socket for 3 c/o screw 1SVR405651R2000 10CR-M4SS Standard socket for 2/4 c/o screw 1SVR405651R3000 10CR-M2SF Standard socket for 2 c/o fork type 1SVR405651R1300 10CR-M4SF Standard socket for 2/4 c/o fork type 1SVR405651R3300 10
Socket accessories
CR-MH Plastic holder 1SVR405659R1000 10CR-MH1 Metal holder 1SVR405659R1100 25CR-MJ Jumper bar for sockets with screw connection 1SVR405658R6000 10
Markers
CR-M Marker 1SVR405658R1000 10
4
3
2
1 1 Socket
2 Pluggable function module
3 Interface relay
4 Holder
stock items
-
55
34 ABB | EPR Selection Tables | 1SXP110002C0201 1SXP110002C0201 | EPR Selection Tables | ABB 35
Pluggable Interface RelaysCR-P Range
4
3
4
2
1 1 Socket
2 Pluggable function module
3 Interface relay
4 Holder
4 Marker label
Input voltage
12 V DC 24 V DC 48 V DC 110 V DC 24 V AC 48 V AC 110 V AC 120 V AC 230 V AC Output rating
250 V 16 A 250 V 8 A Output contacts
c/o 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 2 2 2
Gold contact
Ord
er n
um
ber
1SV
R40
5600
R40
00
1SV
R40
5600
R10
00
1SV
R40
5600
R60
00
1SV
R40
5600
R80
00
1SV
R40
5600
R00
00
1SV
R40
5600
R50
00
1SV
R40
5600
R70
00
1SV
R40
5600
R20
00
1SV
R40
5600
R30
00
1SV
R40
5601
R40
00
1SV
R40
5601
R10
00
1SV
R40
5601
R60
00
1SV
R40
5601
R80
00
1SV
R40
5601
R00
00
1SV
R40
5601
R50
00
1SV
R40
5601
R70
00
1SV
R40
5601
R20
00
1SV
R40
5601
R30
00
1SV
R40
5606
R10
00
1SV
R40
5606
R00
00
1SV
R40
5606
R70
00
1SV
R40
5606
R30
00
Typ
e
CR
-P01
2DC
1
CR
-P02
4DC
1
CR
-P04
8DC
1
CR
-P11
0DC
1
CR
-P02
4AC
1
CR
-P04
8AC
1
CR
-P11
0AC
1
CR
-P12
0AC
1
CR
-P23
0AC
1
CR
-P01
2DC
2
CR
-P02
4DC
2
CR
-P04
8DC
2
CR
-P11
0DC
2
CR
-P02
4AC
2
CR
-P04
8AC
2
CR
-P11
0AC
2
CR
-P12
0AC
2
CR
-P23
0AC
2
CR
-P02
4DC
2G
CR
-P02
4AC
2G
CR
-P11
0AC
2G
CR
-P23
0AC
2G
Accessories - Sockets CR-PType Version Connection terminals Order code Packaging quantity
Sockets
CR-PLS Logical socket with protective
separation
screw 1SVR405650R0000 10
CR-PLSx Logical socket screw 1SVR405650R0100 10CR-PLC Logical socket spring connection 1SVR405650R0200 10CR-PSS Standard socket screw 1SVR405650R1000 10
Socket accessories
CR-PH Plastic Holder 1SVR405659R0000 10CR-PJ Jumper bar for sockets with screw connection 1SVR405658R5000 10
Markers
CR-P Marker 1SVR405658R0000 10
stock items
stock items
-
55
36 ABB | EPR Selection Tables | 1SXP110002C0201 1SXP110002C0201 | EPR Selection Tables | ABB 37
Ord
er n
um
ber
1SV
R40
5621
R40
00
1SV
R40
5621
R10
00
1SV
R40
5621
R60
00
1SV
R40
5621
R80
00
1SV
R40
5621
R90
00
1SV
R40
5621