REINFORCED CONCRETE RETAINING WALLS
Transcript of REINFORCED CONCRETE RETAINING WALLS
6" PLASTIC PIPESCHED. 40
5'±
CO
VER
STORMWATERCATCH BASIN, SEE
DETAIL 3
a
8'-9
1 2"3 4"
STO
NE
RET. WALL ASPER ENGINEER
6" PLASTIC STORMDRAIN SCHED. 40
PROPOSED
STORMTECHMC-3500CHAMBERS (TYP)
C.I. GRATE
BEDDING INCLEAN SAND
PROPOSED GRADE ±
WEEP HOLE
APPROX. GWTAS PER SB&H
A
D1
45'-9
"±
FLOW FLOW
FLOW FLOW
FLOW
FLOW
C
D1
5'± COVER
STORMTECH MC-3500CHAMBERS, SEE
DETAIL 2 ON SW2.0
C
D1
PARKING AREA
PARKING AREAPARKING AREA
DOWNSPOUTFROM ROOF (TYP)
CATCH BASIN (TYP)
CATCH BASIN SEE DETAIL A (TYP)
6"Ø PVC PIPE SCHEDULE 40 (TYP)
6"Ø PVC PIPE SCHEDULE 40 (TYP)
COMMERCIAL ENTERANCE(BELOW GRADE)
8'-912" DEEP
34" STONE
A
D1
REINFORCED CO
NCRETE
RETAINING WALLS
PARKING AREA COVEREDIN PEA-STONE
WEAR-SURFACE TO BE34" COMPACTED STONE.
3" THICK
DRIVEWAY TO BE COVERED WITHCOBBLE STONE PAVERS.
DRIVEWAY TO BE COVERED WITHCOBBLE STONE PAVERS.
VETERAN'SPARK
INSPECTIONPORT, SEE DETAIL
1 ON SW2.0
6" PIPE ALONGSIDESUNKEN WALKWAY
6" PIPE ALONGSIDESUNKEN WALKWAY
PITC
HWAL
WAY
PIP
E TO
DRA
IN IN
C.B
.
C.B.
C.B.
C.B.
C.B.
C.B.
C.B.C.B.C.B.
BRICKWALKWAY
BRICKWALKWAY
BRICKWALKWAY
BRICKWALKWAY
D.S.
D.S. D.S. D.S.
D.S.
AD
DRES
S:
JOH
N L
OLL
EY,
PE
CIV
IL, S
TRU
CTU
RA
L &
SO
ILS
EN
GIN
EE
RIN
GR
ESI
DE
NTI
AL
DE
SIG
N
PO
BO
X 1
858
VIN
EYA
RD
HA
VEN
, MA
SSA
CH
USE
TTS
0256
8PL
AN N
AM
E:
4 S
TATE
RO
AD
,VIN
EYARD
HAVEN
, M
APA
RC
EL ID
: 9
-A-6
TEL:
508
-693
-515
3of
fice@
lolle
ype.
com
JOB NUMBER:
21091
SEE PLANSSCALE:
ISSUED
FO
R:
DATE
:D
RAW
N B
Y:C
HEC
K BY:
CHEC
K SET
9.1
7.2
1VM
C
DATE:
17 SEP 2021
C SITE DRAINAGE SECTION C-CSCALE: 1" = 20'-0"
1 SITE DRAINAGE PLANSCALE: 1" = 20'-0"
STORMWATER MANAGEMENT:DESIGN STORM - 25-YEARDURATION - 24HR
DUKE'S COUNTY:25-YEAR, 24HR STORM = 5.8"/HR
GENERALLY POOR DRAINAGE,BASED ON SITE INSPECTION.
SOIL TYPES INCLUDE SAND,POSSIBLE STRATIFIED CLAY/SILTS,AND INORGANIC SILTS.
SOIL PERMEABILITY ESTIMATED TOBE 10-5 CM/SEC
PVC PIPE FLOW:Ø = 6"FLOW VELOCITY = 6.45FT/SFLOW DISCHARGE = 1.266FT3/S
SW 1.0
PLEASE NOTE:1. STORMTECH COMPACTION REQUIREMENTS ARE MET FOR 'A' LOCATION MATERIALS WHEN PLACED AND COMPACTED IN 9" (230 mm) (MAX) LIFTS USING TWO FULL COVERAGES WITH A VIBRATORY COMPACTOR.2. WHERE INFILTRATION SURFACES MAY BE COMPROMISED BY COMPACTION, FOR STANDARD DESIGN LOAD CONDITIONS, A FLAT SURFACE MAY BE ACHIEVED BY RAKING OR DRAGGING WITHOUT COMPACTION EQUIPMENT. FOR SPECIAL LOAD DESIGNS, CONTACT STORMTECH FOR
COMPACTION REQUIREMENTS.3. ONCE LAYER 'C' IS PLACED, ANY SOIL/MATERIAL CAN BE PLACED IN LAYER 'D' UP TO THE FINISHED GRADE. MOST PAVEMENT SUBBASE SOILS CAN BE USED TO REPLACE THE MATERIAL REQUIREMENTS OF LAYER 'C' OR 'D' AT THE SITE DESIGN ENGINEER'S DISCRETION.
NOTES:1. CHAMBERS SHALL MEET THE REQUIREMENTS OF ASTM F2418-16a, "STANDARD SPECIFICATION FOR POLYPROPYLENE (PP) CORRUGATED WALL STORMWATER COLLECTION CHAMBERS" CHAMBER CLASSIFICATION
45x76 DESIGNATION SS.2. MC-3500 CHAMBERS SHALL BE DESIGNED IN ACCORDANCE WITH ASTM F2787 "STANDARD PRACTICE FOR STRUCTURAL DESIGN OF THERMOPLASTIC CORRUGATED WALL STORMWATER COLLECTION CHAMBERS".3. THE SITE DESIGN ENGINEER IS RESPONSIBLE FOR ASSESSING THE BEARING RESISTANCE (ALLOWABLE BEARING CAPACITY) OF THE SUBGRADE SOILS AND THE DEPTH OF FOUNDATION STONE WITH CONSIDERATION
FOR THE RANGE OF EXPECTED SOIL MOISTURE CONDITIONS.4. PERIMETER STONE MUST BE EXTENDED HORIZONTALLY TO THE EXCAVATION WALL FOR BOTH VERTICAL AND SLOPED EXCAVATION WALLS.5. REQUIREMENTS FOR HANDLING AND INSTALLATION:
· TO MAINTAIN THE WIDTH OF CHAMBERS DURING SHIPPING AND HANDLING, CHAMBERS SHALL HAVE INTEGRAL, INTERLOCKING STACKING LUGS.· TO ENSURE A SECURE JOINT DURING INSTALLATION AND BACKFILL, THE HEIGHT OF THE CHAMBER JOINT SHALL NOT BE LESS THAN 3”.· TO ENSURE THE INTEGRITY OF THE ARCH SHAPE DURING INSTALLATION, a) THE ARCH STIFFNESS CONSTANT AS DEFINED IN SECTION 6.2.8 OF ASTM F2418 SHALL BE GREATER THAN OR EQUAL TO 500 LBS/IN/IN.
AND b) TO RESIST CHAMBER DEFORMATION DURING INSTALLATION AT ELEVATED TEMPERATURES (ABOVE 73° F / 23° C), CHAMBERS SHALL BE PRODUCED FROM REFLECTIVE GOLD OR YELLOW COLORS.
D
FINAL FILL: FILL MATERIAL FOR LAYER 'D' STARTS FROM THETOP OF THE 'C' LAYER TO THE BOTTOM OF FLEXIBLEPAVEMENT OR UNPAVED FINISHED GRADE ABOVE. NOTE THATPAVEMENT SUBBASE MAY BE PART OF THE 'D' LAYER
ANY SOIL/ROCK MATERIALS, NATIVE SOILS, OR PER ENGINEER'S PLANS.CHECK PLANS FOR PAVEMENT SUBGRADE REQUIREMENTS.
PREPARE PER SITE DESIGN ENGINEER'S PLANS. PAVEDINSTALLATIONS MAY HAVE STRINGENT MATERIAL AND
PREPARATION REQUIREMENTS.
C
INITIAL FILL: FILL MATERIAL FOR LAYER 'C' STARTS FROM THETOP OF THE EMBEDMENT STONE ('B' LAYER) TO 24" (600 mm)ABOVE THE TOP OF THE CHAMBER. NOTE THAT PAVEMENTSUBBASE MAY BE A PART OF THE 'C' LAYER.
GRANULAR WELL-GRADED SOIL/AGGREGATE MIXTURES, <35% FINES ORPROCESSED AGGREGATE.
MOST PAVEMENT SUBBASE MATERIALS CAN BE USED IN LIEU OF THISLAYER.
BEGIN COMPACTIONS AFTER 24" (600 mm) OF MATERIAL OVERTHE CHAMBERS IS REACHED. COMPACT ADDITIONAL LAYERS IN12" (300 mm) MAX LIFTS TO A MIN. 95% PROCTOR DENSITY FOR
WELL GRADED MATERIAL AND 95% RELATIVE DENSITY FORPROCESSED AGGREGATE MATERIALS.
BEMBEDMENT STONE: FILL SURROUNDING THE CHAMBERSFROM THE FOUNDATION STONE ('A' LAYER) TO THE 'C' LAYERABOVE.
CLEAN, CRUSHED, ANGULAR STONE PLATE COMPACT OR ROLL TO ACHIEVE A FLAT SURFACE.1,2
AFOUNDATION STONE: FILL BELOW CHAMBERS FROM THESUBGRADE UP TO THE FOOT (BOTTOM) OF THE CHAMBER. CLEAN, CRUSHED, ANGULAR STONE PLATE COMPACT OR ROLL TO ACHIEVE A FLAT SURFACE.1,2
24"(600 mm) MIN*
8'(2.4 m)MAX
12" (300 mm) MIN77" (1950 mm)
ADS GEOSYNTHETICS 601T NON-WOVEN GEOTEXTILE ALLAROUND CLEAN, CRUSHED, ANGULAR STONE IN A & B LAYERS
12" (300 mm) MIN
9"(230 mm) MIN
DC
B
A
*TO BOTTOM OF FLEXIBLE PAVEMENT. FOR UNPAVEDINSTALLATIONS WHERE RUTTING FROM VEHICLES MAY OCCUR,
INCREASE COVER TO 30" (750 mm).
6" (150 mm) MIN
PERIMETER STONE(SEE NOTE 6)
EXCAVATION WALL(CAN BE SLOPED OR VERTICAL)
MC-3500 END CAPSUBGRADE SOILS
(SEE NOTE 4)
PAVEMENT LAYER (DESIGNED BY SITE DESIGN ENGINEER)
45"(1140 mm)
DEPTH OF STONE TO BE DETERMINEDBY SITE DESIGN ENGINEER 9" (230 mm) MIN
**THIS CROSS SECTION DETAIL REPRESENTSMINIMUM REQUIREMENTS FOR INSTALLATION.PLEASE SEE THE LAYOUT SHEET(S) FORPROJECT SPECIFIC REQUIREMENTS.
NOTE:INSPECTION PORTS MAY BE CONNECTED THROUGH ANY CHAMBER CORRUGATION VALLEY.
STORMTECH CHAMBER
CONCRETE COLLAR
PAVEMENT
12" (300 mm) MIN WIDTH
CONCRETE SLAB6" (150 mm) MIN THICKNESS
8" NYLOPLAST INSPECTION PORTBODY (PART# 2708AG4IPKIT) ORTRAFFIC RATED BOX W/SOLIDLOCKING COVER
CONCRETE COLLAR NOT REQUIREDFOR UNPAVED APPLICATIONS
4" (100 mm)SDR 35 PIPE
4" (100 mm) INSERTA TEETO BE CENTERED ONCORRUGATION VALLEY
REV E7001-110-189DWG NO.1 OF 1SHEET1:20SCALEDWG SIZE A
3130 VERONA AVEBUFORD, GA 30518PHN (770) 932-2443FAX (770) 932-2490www.nyloplast-us.com
12 IN DRAIN BASIN QUICK SPEC INSTALLATION DETAILTITLE
PROJECT NO./NAME
MATERIAL
DATE
REVISED BY
03-29-06DATE
EBCDRAWN BY
03-11-16
NMH
(5) ADAPTERANGLES
VARIABLE 0° - 360°ACCORDING TO
PLANS
18" MIN WIDTH GUIDELINE
8" MIN THICKNESS GUIDELINE
(3) VARIABLE SUMP DEPTHACCORDING TO PLANS
(6" MIN. BASED ONMANUFACTURING REQ.)
4" MIN
MINIMUM PIPE BURIALDEPTH PER PIPEMANUFACTURER
RECOMMENDATION(MIN. MANUFACTURING
REQ. SAME AS MIN. SUMP)
(3) VARIABLE INVERT HEIGHTSAVAILABLE (ACCORDING TO
PLANS/TAKE OFF)
NYLOPLAST 12" DRAIN BASIN: 2812AG _ _ X
WATERTIGHT JOINT(CORRUGATED HDPE SHOWN)
(4) VARIOUS TYPES OF INLET & OUTLET ADAPTERS AVAILABLE:4" - 12" FOR CORRUGATED HDPE (ADS N-12/HANCOR DUAL WALL,ADS/HANCOR SINGLE WALL), N-12 HP, PVC SEWER (EX: SDR 35),
PVC DWV (EX: SCH 40), CORRUGATED & RIBBED PVC
(1, 2) INTEGRATED DUCTILE IRONFRAME & GRATE TO MATCH BASIN O.D.
THIS PRINT DISCLOSES SUBJECT MATTER IN WHICHNYLOPLAST HAS PROPRIETARY RIGHTS. THE RECEIPTOR POSSESSION OF THIS PRINT DOES NOT CONFER,TRANSFER, OR LICENSE THE USE OF THE DESIGN ORTECHNICAL INFORMATION SHOWN HEREINREPRODUCTION OF THIS PRINT OR ANY INFORMATIONCONTAINED HEREIN, OR MANUFACTURE OF ANYARTICLE HEREFROM, FOR THE DISCLOSURE TO OTHERSIS FORBIDDEN, EXCEPT BY SPECIFIC WRITTENPERMISSION FROM NYLOPLAST.
1 - GRATES/SOLID COVER SHALL BE DUCTILE IRON PER ASTM A536 GRADE 70-50-05, WITH THE EXCEPTION OF THE BRONZE GRATE.2 - FRAMES SHALL BE DUCTILE IRON PER ASTM A536 GRADE 70-50-053 - DRAIN BASIN TO BE CUSTOM MANUFACTURED ACCORDING TO PLAN DETAILS. RISERS ARE NEEDED FOR BASINS OVER 84" DUE TO SHIPPING RESTRICTIONS. SEE DRAWING NO. 7001-110-0654 - DRAINAGE CONNECTION STUB JOINT TIGHTNESS SHALL CONFORM TO ASTM D3212 FOR CORRUGATED HDPE (ADS N-12/HANCOR DUAL WALL), N-12 HP, & PVC SEWER.5 - ADAPTERS CAN BE MOUNTED ON ANY ANGLE 0° TO 360°. TO DETERMINE MINIMUM ANGLE BETWEEN ADAPTERS SEE DRAWING NO. 7001-110-012.
TRAFFIC LOADS: CONCRETE SLAB DIMENSIONS ARE FORGUIDELINE PURPOSES ONLY. ACTUAL CONCRETE SLAB MUST BEDESIGNED TAKING INTO CONSIDERATION LOCAL SOIL CONDITIONS,TRAFFIC LOADING, & OTHER APPLICABLE DESIGN FACTORS.SEE DRAWING NO. 7001-110-111 FOR NON TRAFFIC INSTALLATION.
THE BACKFILL MATERIAL SHALL BE CRUSHED STONE OR OTHERGRANULAR MATERIAL MEETING THE REQUIREMENTS OF CLASS I,
CLASS II, OR CLASS III MATERIAL AS DEFINED IN ASTM D2321.BEDDING & BACKFILL FOR SURFACE DRAINAGE INLETS SHALL BE
PLACED & COMPACTED UNIFORMLY IN ACCORDANCE WITH ASTM D2321.
®
©2013 NYLOPLAST
1 DETAIL 1: INSPECTION PORTNOT TO SCLAE
2 DETAIL 2: DETAIL OF INFILTRATION SYSTEMNOT TO SCALE
AD
DRES
S:
JOH
N L
OLL
EY,
PE
CIV
IL, S
TRU
CTU
RA
L &
SO
ILS
EN
GIN
EE
RIN
GR
ESI
DE
NTI
AL
DE
SIG
N
PO
BO
X 1
858
VIN
EYA
RD
HA
VEN
, MA
SSA
CH
USE
TTS
0256
8PL
AN N
AM
E:
4 S
TATE
RO
AD
,VIN
EYARD
HAVEN
, M
APA
RC
EL ID
: 9
-A-6
TEL:
508
-693
-515
3of
fice@
lolle
ype.
com
JOB NUMBER:
21091
SEE PLANSSCALE:
ISSUED
FO
R:
DATE
:D
RAW
N B
Y:C
HEC
K BY:
CHEC
K SET
9.1
7.2
1VM
C
DATE:
17 SEP 2021
3 DETAIL 3: STORMWATER CATCH BASIN FOR COMMERCIAL AREANOT TO SCALE
SW 2.0