Refrigeration System.pdf
-
Upload
lupudaniel2005 -
Category
Documents
-
view
2 -
download
0
Transcript of Refrigeration System.pdf
-
a1
Manual
defrost
3x440V
TS-B27
a62
1,2,3
R,S,T
m1
440V / 220V1c1
1e1
4,5,6
16/25
De
fro
st
He
at
rse
1c2
1e2
12,13,14
4/25
1e3
3~M
1m1
1e4
3~M
1m2
15,16,17
Fans
1c1
1e1
4,5,6
16/25
De
fro
st
He
at
rse
2c1
2e1
19,20
16/25
rD
ef
ost
ars
He
te
2c2
2e2 4/25
2e4
1~M
2m2
30,31
Fan
16/25
rD
ef
ost
ars
He
te
440V
220V
3c1
3e1 16/25
De
rofst
at
rsH
ee
3c2
3e2
42,43,44
4/25
3e3
3~M
3m1
3e4
3~M
3m2
45,46,47
Fans
34,35,36
NO.1 MEAT ROOM
-20C
NO.2 MEAT ROOM
-20C
FISH ROOM
-20C
8c1
8e1
68,69,70
8e2
3~M
8m1
8e4
71,72,73
Port
Compressor
4c1
4e1 2/25
4e2
3~M
4m1
50,51,52
Fan
5c1
5e1 2/25
5e2
3~M
5m1
56,57,58
Fan
6c1
6e1 6/25
6e2
3~M
6m1
62,63,64
Port
Pump
7c1
7e1 6/25
7e2
3~M
7m1
65,66,67
Stbd
Pump
8c3
8e3
9c1
9e1
84,85,86
9e2
3~M
9m1
9e4
87,88,89
Stbd
Compressor
9c3
9e3
VEGETABLE ROOM
+3C
MILK ROOM
+6C
COOLING
SEA WATER PUMPS
COMPRESSORS
POWER REFRIGERATION PLANT
PAGE 1 of 1
-
e1R
S
e1
m1
e4
H
A
B
u1
1
2
1d1
B
A
1
2
1d1
1e610 11
No.1 meat room
safety
termoswitch
1c1
14
13
1c1
3c1 2c1 1c11d1
b1
Manual
defrost
1b1
M A 1e5
9 8
No.1 meat room
termoswitch
7
1c2h1
96
95
96
95
98
97
1e4
1e398
2e624 25
No.2 meat room
safety
termoswitch
2c1
440V 220V
e2 & e3
fuse
11 12 13 14 21 22 21 22
44
43
h2
2c1
Auto
defrost
Defrost
Meat room No.1
Meat room No.1
Evaporator fan
Defrost
Meat room No.2
B
A
B
A
B
A
REFRIGERATION CONTROLS
PAGE 1 of 4
1
2
-
2b1
M A 2e5
23 22
No.2 meat room
termoswitch
21
2c2
B
A
96
95
96
95
98
97
2e4
2e3
98
3e640 41
Fish room
safety
termoswitch
3c1
Meat room No.2
Evaporator fan
14
13
2c2
2s1
32
33
B
A
14
13
h3
3c1
Meat room
Solenoid valve
Defrost
Fish room
3b1
M A 3e5
39 38
Fish room
termoswitch
37
3c2
B
A
96
95
96
95
98
97
3e4
3e3
98
Meat room No.2
Evaporator fan
14
13
3c2
3s1
48
49
Meat room
Solenoid valve
4b1
M A 4e3
55 54
Vegetable room
termoswitch
53
4c1
B
A
96
95
98
97
4e2
Fish room
Evaporator fan
h4
Alarm
(RED)
REFRIGERATION CONTROLS
PAGE 2 of 4
-
5b1
M A 5e3
61 60
Milk room
termoswitch
59
5c1
B
A
96
95
98
97
5e2
Fish room
Evaporator fan
Alarm
Engine room
d4
B
A
d5
B
A
14
13
6h1
6c1
6b1
6c1
B
A
96
95
98
6e2
7c1A
41
42
7c1
B
96
95
98
7e2
42
41
6c1
1
2 3 4
14
13
7c1
24
23
6c1
24
23
7h1
7c1
34
33
d5
96
9596
95
8e2
8e4
8b1
MA
P
P
7678
74
758e5
Pressure
switch
LH-HP
79
80
8e6
OIL
Pressure
switch
L
M
81
110V
220V
77
98
98
14
13
8c1
13
14
8c2 8h1 CH
8b2
1
2 3 4
32
31
8c2 8c1
32
31
8c1A
B
8c2A
B
PV
1150T/m
GV
1750T/m
Compressor
Stop
Defrost
Port Sea
Water Pump
Stb. Sea
Water Pump
Port
Compressor
Low
Speed
High
Speed
REFRIGERATION CONTROLS
PAGE 3 of 4
-
96
9596
95
9e2
9e4
9b1
MA
P
P
9294
90
919e5
Pressure
switch
LH-HP
95
96
9e6
OIL
Pressure
switch
L
M
97
110V
220V
93
98
98
14
13
9c1
13
14
9c2 9h1 CH
9b2
1
2 3 4
31
32
9c2 9c1
21
22
9c1A
B
9c2A
B
PV
1150T/m
GV
1750T/m
Stbd.
Compressor
Low
Speed
High
Speed
S1
100
101
Return
Solenoid valve
24
23
8c1
24
23
8c2
44
43
9c1
24
23
9c2
m1
e3
e2
2AGF
2AGF
8c2
41
42
8b3
8c1
42
41
82
83
O
I
L at
rH
ee
9c2
41
42
9b3
9c1
32
31
98
99
O
IL
rH
eate
80W80W
Crank Case
Port Compressor
Heater
Crank Case
Stbd Compressor
Heater
24
23
d4
To ECR
Alarm
REFRIGERATION CONTROLS
PAGE 4 of 4
Refrigeration System 1.pdfPage 1
Refrigeration System.pdfRefrigeration System Page 1.pdfPage 1
Refrigeration System Page 2.pdfPage 1
Refrigeration System Page 3.pdfPage 1
Refrigeration System Page 4.pdfPage 1