Reference standards Bujji Kanchi. Purpose Identification Quantification.

26
Reference standards Bujji Kanchi

Transcript of Reference standards Bujji Kanchi. Purpose Identification Quantification.

Page 1: Reference standards Bujji Kanchi. Purpose Identification Quantification.

Reference standards

Bujji Kanchi

Page 2: Reference standards Bujji Kanchi. Purpose Identification Quantification.

Purpose

• Identification• Quantification

Page 3: Reference standards Bujji Kanchi. Purpose Identification Quantification.

Akbar wants to shorten the line

Using Reference standard line only, We should compare and judge

Page 4: Reference standards Bujji Kanchi. Purpose Identification Quantification.

How to Measure length ?

• Using a scale.

• Then, Scale is a Reference standard to measure.

Page 5: Reference standards Bujji Kanchi. Purpose Identification Quantification.

Do U want to measure weight of ?

In daily life, we use to buy things by measuring against standard weights

So, For every measurement, There needs a reference standard.

Hence for every quantification, Reference standard is required for accuracy

Page 6: Reference standards Bujji Kanchi. Purpose Identification Quantification.

Identification

• Any material is identified with its reference standard.

• A material is compared against its reference standard for Identity. Eg: IR

Page 7: Reference standards Bujji Kanchi. Purpose Identification Quantification.

Types of Standards• Reference standards are of two types

1. Primary Reference standards. 2. Secondary Reference standard or working reference standard.

Page 8: Reference standards Bujji Kanchi. Purpose Identification Quantification.

Primary Reference standards or primary standards

• Primary standards are the chemical substances which are accepted without reference to other standards.

• No testing is required for primary reference standard, directly it can be used with out further testing in our lab.

Page 9: Reference standards Bujji Kanchi. Purpose Identification Quantification.

Primary Reference standardPharmacopial or In-house

• Primary standard may be obtained from the USP/NF or EP or BP and other official sources or prepared by the manufacturer.

• If there is no official source to obtain material (In-house products).

Page 10: Reference standards Bujji Kanchi. Purpose Identification Quantification.

Primary std should be properly identified.

• Primary standards are characterized for proper identification by exclusive testing like

• IR• NMR• MASS• UV/Vis• CHN analysis

Page 11: Reference standards Bujji Kanchi. Purpose Identification Quantification.

Evaluation of potency.

• %Potency = 100-All impurities(including water and residual solvents)• If a standard requires drying, the required amount must be

transferred to a clean weighing bottle for drying. • The weighing bottle must be protected from light during use. Dried

standards must not be returned to the original bottle in order to avoid any possible contamination of the stock. After drying, place the standard into the desiccator to equilibrate before assaying.

Page 12: Reference standards Bujji Kanchi. Purpose Identification Quantification.

Working reference standard

• Pharmacopeial primary standards are costly and single use only. We can not buy every time.

• To over come this, Instead of Primary standards, working

standard can be used.

Page 13: Reference standards Bujji Kanchi. Purpose Identification Quantification.

Packing and labeling

• Pharmacopial PRS should be used directly for any testing, No further packing is required.

• In-house PRS should be packed in 12 amber color glass bottle for one year,

• Each bottle should be used for only one month.

Page 14: Reference standards Bujji Kanchi. Purpose Identification Quantification.

Packing and labelling

• This is a best practice to avoid attacking Moisture from atmosphere for multiple use.

• Three buffer vials should be kept for sake of spillage or customer requirement etc..

• Pack the working standard like In-house PRSPacking for one year

• 12 containers+ 3 buffer containers

Page 15: Reference standards Bujji Kanchi. Purpose Identification Quantification.

COA for PRS

• Pharmacopial standard does not provide COA• Only certificate is provided.• We should check that # The current lot of primary standard should be

in place.• In-house PRS should have COA.

Page 16: Reference standards Bujji Kanchi. Purpose Identification Quantification.

USP Certificate

Page 17: Reference standards Bujji Kanchi. Purpose Identification Quantification.

Working standard

• A working standard is a standard that is qualified against and used instead of the reference standard.

• There are generally used for regular analysis of drug substances.

• Working standard becomes In-house.• COA is prepared.

Page 18: Reference standards Bujji Kanchi. Purpose Identification Quantification.

Retest or Expiration dating:

• The retest or expirations dating for primary reference standards can be obtained from the official source. In case of in-house reference standards retest date can be assigned by the stability and sensitivity of drug substance.

• In case of secondary standards, usually one year is the retest period. This parameter always depends on the stability of the drug substance.

Page 19: Reference standards Bujji Kanchi. Purpose Identification Quantification.

Storage of Standards

• Working standards are stored in the same manner as indicated by the official source or stability of the standard and are stored in amber glass containers, protected from light, heat and moisture.

Page 20: Reference standards Bujji Kanchi. Purpose Identification Quantification.

Storage of Standards

• Working standards should be kept at ambient conditions in an amber dissector cabinet, unless otherwise specified by the individual monograph and if the standard that require storage in a "cold" or "dry" place are to be stored in a refrigerator at 2-8°C.

Page 21: Reference standards Bujji Kanchi. Purpose Identification Quantification.

Working standard

• Working standard purity is verified periodically, If it is been used for more than one year.

• Even for Key starting materials, In-house PRS must be evaluated and used.

• Select the batch for the working standard qualification, which is highly pure.

Page 22: Reference standards Bujji Kanchi. Purpose Identification Quantification.

Precautions

• Working standard can not be used for qualifying another working standard

• Expired vials should not be used.• Current lot should be used for Pharmacopial

standards• Current lot of In-house standards should be in

place for every month

Page 23: Reference standards Bujji Kanchi. Purpose Identification Quantification.

Correct labeling of vials

Page 24: Reference standards Bujji Kanchi. Purpose Identification Quantification.

Inward and Consumption of Pharmacopeial standard

• Inward should be maintained for each purchase of standard .

• Usage log must be recorded.

Page 25: Reference standards Bujji Kanchi. Purpose Identification Quantification.

Usage # Pharmacopial standards

Pharmacopial standards for Multiple useUsed for Identification Eg: MR standards.-----------------------------------------------

Pharmacopial standards for single useUsed for quantification

Page 26: Reference standards Bujji Kanchi. Purpose Identification Quantification.

Thank you

• Questions ?